RENEWABLE ENERGY SUNSYS HPS Hybrid Power Systems from 40 kVA to 1.2 MVA
Dec 15, 2015
RENEWABLE ENERGY
SUNSYS HPSHybrid Power Systems
from 40 kVA to 1.2 MVA
2 Renewable Energy - SOCOMEC
Minimise energy costs, even in hard-to-reach locations
These areas, which are not served by the public power grid, are supplied by diesel generators, resulting in high indirect and direct energy costs:• fluctuating price of diesel,• high shipping costs,• premature aging on gensets operating
at reduced power,• maintenance costs…
Electrified locations by diesel generators requirements:• Reduce costs linked to diesel
consumption and supply.• Maximise the service life of gensets.• Reduce CO2 emissions.
Non-electrified location requirements:• Provide quick, easy energy access in
areas far away from existing power grids.• Minimise costs linked to diesel
consumption & supply.
Subject to frequent outages, these areas are characterised by an unreliable power supply and high costs due to the use of generating sets (genset maintenance, shipping of diesel).
Requirements:• Ensure a continuous power supply.• Reduce costs linked to diesel
consumption.• Reduce CO2 emissions.
Solar panels
Batteries
AC loads
AC input fromgrid and/or genset
SUNSYS HPS (Hybrid Power System)
site
_678
_a
site
_679
_a
sydi
v_14
1_a_
gb
SOCOMEC SUNSYS HPS hybrid solution enables accessing to an uninterrupted, cheaper and environmental-friendly energy. The use of diesel generators is reduced thanks to the integration of a photovoltaic plant in the electric system.
Remote locations SUNSYS HPS solution benefits to accelerate the return on investment
Locations connected to a disturbed public power grid
Why SOCOMEC ?
• Independent manufacturer Founded in 1922, the company employs over 3000 staff at 30 subsidiaries across five continents.
• Specialist Solutions for power availability, control, safety and energy efficiency.
• Expert Manufacturer of energy conversion solutions for over 40 years.
• At your service A global network of consulting, inspection and maintenance teams.
• Flexible We adapt our solutions to suit the specific needs of our customers.
• Innovative SOCOMEC devotes almost 10 % of its turnover to R&D.
Reuse and optimisation of the existing diesel generator
SUNSYS HPS adapts to the existing genset and limits its operation at reduced power.This helps prevent premature wear and significantly reduces maintenance costs.
Simple and easy to install
Compact and centralized solution, the SUNSYS HPS is simple and quick to install.The cost of its implementation is therefore extremely reduced.
Extensive power range up to 1.2 MVA
The SUNSYS HPS standard solution is available for power ratings from 40 kVA to 200 kVA. Based on a parallelable modular architecture, it allows power scalability up to 1.2 MVA.
Manufacturer’s warranty for global solution
SOCOMEC designs and manufactures the solution in its entirety: converter, AC and DC protection, main LV board. This guarantees all-round system operation and performance.
3SOCOMEC - Renewable Energy
The SUNSYS HPS range
SUNSYS HPS MODEL SUNSYS-HPS-40
SUNSYS-HPS-60
SUNSYS-HPS-80
SUNSYS-HPS-100
SUNSYS-HPS-120
SUNSYS-HPS-160
SUNSYS-HPS-200
AC output Nominal Power 40 kVA 60 kVA 80 kVA 100 kVA 120 kVA 160 kVA 200 kVA
AC Active Power 32 kW 48 kW 64 kW 80 kW 100 kW 128 kW 160 kW
Parallel configuration Up to 6 units to reach 1.2 MVA
AC output voltage 380 / 400 / 415 VAC adjustable / 3 phases + Neutral (± 1%)
AC output frequency 50 / 60 Hz adjustable (± 0.2 Hz)
THDV < 2 %
Crest Factor 3.1
Overload 125 % for 10 min / 150 % for 1 min
Max voltage of the PV production 900 VDC
MPPT* voltage range of the PV production 480 to 900 VDC
Max Photovoltaic Power** 30 kWp 80 kWp 80 kWp 160 kWp 160 kWp 160 kWp 240 kWp
Efficiency 94 %
Battery configuration From 174 to 192 Cells
Battery type VRLA and open vent for hybrid applications
Battery AC ripple current < 0.1 C10
Battery AC ripple voltage < 2 %
Max recharge current Adjustable up to 20 % C10 in AC / DC converter - Adjustable up to 20 % C10 in DC / DC converter
Grid / Genset voltage 380 / 400 / 415 VAC / 3 phases + Neutral (± 15%)
Grid / Genset frequency 50 / 60 Hz (± 5 Hz)
Storage & transport ambient temperature -20 °C to 70 °C
Operational Temperature 0 °C to 40 °C depending on the model / 25 °C are recommended to extend the shelf-life
Relative Humidity 0 to 95 % without condensation
IP Rating IP20*: Maximum Power Point Tracking. **: Different power sizes are available.
SOCOMEC SERVICES YOUR BENEFITS
24 / 7 call centre • SOCOMEC hot-line with specialists, maintenance engineers and technicians available 24 / 7
• 24 / 7, fast and efficient response• Reduced system downtime
Remote monitoring • Automatic anomaly detection and notification• Proactive remote diagnostic & troubleshooting actions• Regular reports about SUNSYS HPS health
• System uptime• Prevention and fault detection• Diagnostic accuracy• SUNSYS HPS status updating
Commissioning & training • Correct start-up of the SUNSYS HPS• Compliancy and compatibility with the environments
and other installations• On-site training on first aid of intervention, including
practical sessions
• SUNSYS HPS correct installation, start-up and safe operation
• Local knowledge improvement (1st intervention level)
Preventative maintenance visit • General and exhaustive SUNSYS HPS inspection• Check of battery status• SUNSYS HPS status report & recommendations
• System efficiency• SUNSYS HPS performances• System availability
Consumable parts replacement • Preventive fan & capacitor replacement
Battery replacement • Preventive battery replacement
Corrective intervention on site • On site Intervention • Accurate Problem Solving
Each codified equipment is composed of:
• 1 double AC / DC converter.• 1 DC / DC converter.• 1 battery protection unit.• 1 input / output electrical distribution panel.
Additionnal equipments:
(Definitions & Quotations on request)• Battery rack.• Photovoltaic Field Boxes.• Fully equipped shelter.
For applications requiring powers from 240 kVA up to 1.2 MVA, SOCOMEC offers a complete engineering service to meet the exact needs.
DO
C 1
8704
3 -
11 / 1
3 -
Pho
to: M
artin
Ber
nhar
t - C
reat
ed b
y: S
OC
OM
EC
- G
yss
Impr
imeu
r O
bern
ai
www.socomec.com
heaD oFFice
SOCOMEC GROUPS.A. SOCOMEC capital 10 816 800€ R.C.S. Strasbourg B 548 500 149 B.P. 60010 - 1, rue de Westhouse F-67235 Benfeld Cedex - FRANCE Tel. +33 3 88 57 41 41 Fax +33 3 88 74 08 00 [email protected]
Socomec worldwide
BELGIUMUPS / Power Control & Energy Efficiency / SolarTel. +32 2 340 02 30 Fax +32 2 346 28 99 [email protected]
FRANCEUPS / Power Control & Energy Efficiency / SolarTel. +33 1 45 14 63 00 Fax +33 1 48 67 31 12 [email protected]
GERMANYPower Control & Energy EfficiencyTel. +49 7243 65292 0 Fax +49 7243 65292 13 [email protected]. +49 621 71 68 40 Fax +49 621 71 68 444 [email protected]
ITALYPower Control & Energy EfficiencyTel.+39 02 98 49 821 Fax +39 02 98 24 33 10 [email protected]. +39 0444 598611 Fax +39 0444 598627 [email protected] Tel.+39 02 98 242 942 Fax +39 02 98 240 723 [email protected]
NETHERLANDSUPS / Power Control & Energy Efficiency / SolarTel. +31 30 760 0900 Fax +31 30 637 2166 [email protected]
POLANDPower Control & Energy EfficiencyTel. +48 91 442 64 11 Fax +48 91 442 64 19 [email protected]. +48 22 825 73 60 Fax. +48 22 825 73 60 [email protected]
PORTUGALUPS / SolarTel.+351 261 812 599 Fax +351 261 812 570 [email protected]
ROMANIAUPS / Power Control & Energy Efficiency / SolarTel. +40 21 319 36 88 Fax +40 21 319 36 89 [email protected]
RUSSIAUPS / Power Control & Energy Efficiency / SolarTel. +7 495 775 19 85 Fax +7 495 775 19 85 [email protected]
SLOVENIAUPS / Power Control & Energy Efficiency / SolarTel. +386 1 5807 860 Fax +386 1 561 11 73 [email protected]
SPAINUPS / Power Control & Energy Efficiency / SolarTel. +34 93 540 75 75 Fax +34 93 540 75 76 [email protected]
UNITED KINGDOMPower Control & Energy EfficiencyTel. +44 1462 440 033 Fax +44 1462 431 143 [email protected].+44 1285 863 300 Fax+44 1285 862 304 [email protected]
TURKEYUPS / Power Control & Energy Efficiency / SolarTel. +90 216 540 71 20-21-22 Fax +90 216 540 71 27 [email protected]
non
con
trac
tual
doc
umen
t. ©
201
3, s
ocom
ec s
a. a
ll rig
hts
rese
rved
. - T
o he
lp p
rote
ct th
e en
viro
nmen
t, th
is d
ocum
ent h
as b
een
prin
ted
on P
eFc
pap
er (P
rogr
amm
e fo
r th
e e
ndor
sem
ent o
f For
est c
ertif
icat
ion)
.
YoUr DisTriBUTor
in asia PaciFic
AUSTRALIAUPSTel. +61 2 9325 3900 Fax +61 2 9888 9544 [email protected]
CHINAUPS / Power Control & Energy EfficiencyTel. +86 21 52 98 95 55 Fax +86 21 62 28 34 68 [email protected]
INDIAPower Control & Energy EfficiencyTel. +91 124 4027210 Fax +91 124 4562738 [email protected] / SolarTel. +91 44 39215400 Fax +91 44 39215450 & 51 [email protected] [email protected]
SINGAPORE UPS / Power Control & Energy EfficiencyTel.+65 6506 7600 Fax +65 64 58 7377 [email protected]
THAILANDUPSTel. +66 2 941 1644 7 Fax +66 2 941 1650 [email protected]
VIETNAMUPSTel. +84 8 3559 1220 Fax +84 8 3559 1221 [email protected]
in MiDDle easT
UNITED ARAB EMIRATESUPS / Power Control & Energy Efficiency / SolarTel.+971 4 29 98 441 Fax +971 4 29 98 449 [email protected]
in aMerica
USA, CANADA & MEXICOPower Control & Energy EfficiencyTel. +1 617 245 0447 Fax +1 617 245 0437 [email protected]
oTher coUnTries
NORTH AFRICAAlgeria / Morocco / [email protected]
AFRICAOther [email protected]
SOUTH EUROPECyprus / Greece / Israel / [email protected]
SOUTH AMERICATel. +34 93 540 75 75 [email protected]
MORE DETAILSwww.socomec.com/worldwide
in eUroPe