REV. DATE DESCRIPTION BY CKD. BY WEIGHT POUNDS VOLUME CUBIC FEET FIGURE NUMBER LOCATION FIGURE NUMBER DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICE WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA DRAWN BY: CHECKED BY: APPROVED BY: DATE: SCALE: SIZE A DRAWING NUMBER Trap Primer Connection (When Specified) FLOOR OR SHOWER DRAINS WITH ADJUSTABLE STRAINER HEADS FUNCTION: General service floor drain for use in showers, toilets, kitchens, and other finished areas where foot traffic is expected. The round top strainer head is used for all types of poured finished floors. The square top is particularly adaptable to floors that are finished in material of square or straight line pattern. Reversible flashing collar permits adjustment to meet finished floor level. REGULARLY FURNISHED: Duco Cast Iron Body with Flashing Collar and Adjustable Strainer Head as Indicated by Suffix Letter Selected. Fig. 2010C . . . . . (A) ROUND TOP Fig. 2010C . . . . . (B) SQUARE TOP CAULK OUTLET 2010,2015 2010, 2015 CR 5-17-85 NONE S2010, 2015 A (Pipe Size) = 02(50), 03(80) or 04(100) 9 (230) DIA B DIA or SQ Low Position High Position 4 (100) A 1 1/4 (32) X- MIN MAX XX- MIN MAX 3 (76) Fig. 2015T. . . . . (A) ROUND TOP Fig. 2015T . . . . . (B) SQUARE TOP B DIA or SQ X- MIN MAX D A E F G XX- MIN MAX THREADED OUTLET •Add 3/8" (10) to all min./max. dimensions for round strainer. ••Not available for 05" (125) size strainer. *Collar is reversible to obtain extreme high and low strainer positions. OPTIONAL MATERIALS: Bronze Body -BB (Fig. 2010 only) Chrome Plated Strainer -CP Galvanized Cast Iron Body -G Nickel Bronze Strainer -NB Polished Bronze Strainer -PB Stainless Steel (Specify Fig. 9700-A) (Fig. 2010 only) VARIATIONS: Ball Float Backwater Valve -BFV (Fig. 2015 only) Flapper Type Backwater Valve -V Hinged Grate -H Sediment Bucket -B Trap Primer Connection -P050 1/2" (13) & -P075 3/4" (19) Vandal Proof Screws -U Wide Flanged Strainer (Specify Fig. DX 2010) T Threaded Outlet SEE PM0457 FOR OPTIONAL STRAINER HEADS. •• TD TD K G 7-1-94 Revised CMB Seepage Openings 3/4 (19) 3/4 (19) 7/8 (22) 1 (25) 1 (25) 1 (25) 1 5/8 (41) 1 5/8 (41) 1 7/8 (48) 1 7/8 (48) 1 7/8 (48) 1 7/8 (48) 05 (125) 06 (150) 07 (180) 08 (205) 09 (230) 10 (255) Strainer Size *Collar In High Position *Collar In Low Position Free Area SQ IN (SQ CM) B X XX DIA or SQ MIN MAX ROUND SQUARE MIN MAX • • 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 2 1/4 (57) 2 1/4 (57) 2 1/4 (57) 2 1/2 (64) 2 3/8 (60) 2 3/8 (60) 7 (45) 9 (58) 14 (90) 17 (110) 18 (116) 23 (148) 6.5 (42) 12.5 (81) 11 (71) 14 (90) 16 (103) 16 (103) A SIZE 02 (50) 03 (80) 04 (100) B 05 (125) 06 (150) 08 (200) D 2 3/4 (70) 2 3/4 (70) 3 1/4 (83) E 1 1/4 (32) 2 1/4 (57) 3 1/4 (83) F 4 3/4 (120) 4 3/4 (120) 6 (150) G 5 (125) 5 (125) 4 (100) 1 1/4 (32) 1 1/4 (32) 1 1/2 (38) 2 1/4 (57) 2 1/4 (57) 2 1/2 (64) 3/4 (19) 3/4 (19) - 1 5/8 (41) 1 5/8 (41) - MIN-X-MAX MIN-XX-MA X NOTE: Dimensions shown in parentheses are in millimeters. BS H 6-15-95 Added Millimeters EMB * BS J 5-11-05 Revised ANSI note JJ K 9-22-06 Revised ANSI note RN CL AM Meets ASME Standard A112.6.3-2001 02(50), 03(75) or 04"(100) sizes only. JAY R. SMITH MFG. CO. ® DIVISION OF SMITH INDUSTRIES, INC. POST OFFICE BOX 3237 MONTGOMERY, ALABAMA 36109-0237 (USA) TEL: 334-277-8520 FAX: 334-272-7396 www.jrsmith.com CUSTOMER DRIVEN SMITH ® MEMBER OF: ® ASPE ® S A N I T A R Y E N G I NE E R I N G P r e v e n tio n R ath er T h a n C u r e
3
Embed
SMITH JAY R. LOCATION K SMITH MFG. CO. POST OFFICE BOX ...
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
REV. DATE DESCRIPTION BY CKD. BY
WEIGHTPOUNDS
VOLUMECUBIC FEET
FIGURE NUMBER
LOCATIONF
IGU
RE
NU
MB
ER
DIM
EN
SIO
NS
AR
E S
UB
JEC
T T
O M
AN
UF
AC
TU
RE
RS
TO
LER
AN
CE
AN
D C
HA
NG
E W
ITH
OU
T N
OT
ICE
WE
CA
N A
SS
UM
E N
O R
ES
PO
NS
IBIL
ITY
FO
R U
SE
OF
SU
PE
RS
ED
ED
OR
VO
ID D
AT
A
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
AP
PR
OV
ED
BY
:D
AT
E:
SC
ALE
:S
IZE A
DR
AW
ING
NU
MB
ER
Trap PrimerConnection(When Specified)
FLOOR OR SHOWER DRAINSWITH ADJUSTABLE STRAINER HEADS
FUNCTION: General service floor drain for use in showers, toilets, kitchens, and other finished areas where foot traffic isexpected. The round top strainer head is used for all types of poured finished floors. The square top is particularlyadaptable to floors that are finished in material of square or straight line pattern. Reversible flashing collar permitsadjustment to meet finished floor level.
REGULARLY FURNISHED:Duco Cast Iron Body with Flashing Collarand Adjustable Strainer Head as Indicatedby Suffix Letter Selected.
•Add 3/8" (10) to all min./max. dimensions for round strainer.••Not available for 05" (125) size strainer.*Collar is reversible to obtain extreme high and low strainer positions.
OPTIONAL MATERIALS:Bronze Body -BB (Fig. 2010 only)Chrome Plated Strainer -CPGalvanized Cast Iron Body -GNickel Bronze Strainer -NBPolished Bronze Strainer -PBStainless Steel (Specify Fig. 9700-A) (Fig. 2010 only)
B DIA 05 (125) 06 (150) 08 (205) 10 (255) H 2 (51) 2 (51) 2 1/2 (64) 2 3/4 (70) MIN 1 1/4 (32) 1 1/4 (32) 1 1/2 (38) 1 7/8 (48) MAX 2 1/4 (57) 2 1/4 (57) 2 1/2 (64) 2 3/4 (70)
FUNCTION: Used in finished floors where light wheeled loads are anticipated.
B
H
TILE FLANGE
Specify Type, Size & Finish eg: F06NB
FUNCTION: Provides integral flange set 5/32" (4) below rim to receive floor covering. Flange may have option of tapped holes for securing pan and gasket.
FUNCTION: Used in a non-traffic area when a funnel type strainer head is required and space does not allow use of the 3500 series funnel. The extended rim allows use as an anti-flood and anti-splash drip pan.
MATERIALS:VARIATIONS:Flapper Type Backwater Valve (Specify Suffix -F37V or F38V)
Cast Iron -CIChrome Plated -CPGalvanized Cast Iron -GPolished Bronze -PB
ADJUSTABLE STRAINER HEAD
B
HSUFFIX -F37 -F38 B DIA 07 (180) 09 (230) H 3 1/4 (83) 3 1/2 (89) MIN 2 5/8 (67) 2 3/4 (70) MAX 3 1/2 (89) 3 1/2 (89)X
2010 SERIES OPTIONALSTRAINER HEADS
1 0f 2
2010
SE
RIE
S O
PT
ION
AL
ST
RA
INE
R H
EA
DS
FIG
UR
E
NU
MB
ER
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
AP
PR
OV
ED
BY
:D
AT
E:
SC
ALE
DR
AW
ING
NU
MB
ER
DIM
EN
SIO
NS
AR
E S
UB
JEC
T T
O M
AN
UF
AC
TU
RE
RS
TO
LER
AN
CE
AN
D C
HA
NG
E W
ITH
OU
T N
OT
ICE
AS
SU
ME
NO
RE
SP
ON
SIB
ILIT
OR
US
E O
F S
UP
ER
SE
DE
D O
R V
OID
DA
TA
SIZ
E
SUFFIX -AV
Specify Type, Size & Finish eg: AV05NB*Not available for 05" (125) size
FLAPPER TYPE BACKWATER VALVE
MATERIALS:Chrome Plated -CPPolished Bronze -PB
FUNCTION: Provides backwater pro-tection at point where protection is needed.
VARIATIONS
B
H
B DIA 05 (125) 06 (150) 07 (180) 08 (205) H 2 (51) 2 (51) 2 1/4 (57) 2 1/2 (64) MIN 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/2 (38) MAX 2 1/4 (57) 2 1/4 (57) 2 1/4 (57) 2 1/2 (64)
X
SUFFIX -D-E Specify Type, Size & Finish eg:
REINFORCED TRACTOR STRAINER
MATERIALS:Cast Iron -CIChrome Plated -CPPolished Bronze -PB
FUNCTION: Used in finished floors where medium weight wheeled loads are anticipated and loose set non-tilt tractor grate is desired.
VARIATIONS:
B
H
SUFFIX B H X DIA MIN MAX -D 07 (180) 3 1/4 (83) 2 5/8 (67) 3 1/2 (89) -E 09 (230) 3 1/2 (89) 2 3/4 (70) 3 1/2 (89)
REV. DATE DESCRIPTION BY CKD. BY
PJ
TD
TD
5-17
-85
NO
NE
PM
0457
SH
1 o
f 2G
6 (150)
3 1/8 (79)
6 (150)7 1/2 (190)
5/32 (4)
2 (51)
NOTE: Dimensions shown in parenthesis are in millimeters.
SUFFIX -F
BSE 11-4-97 Added Nickel Bronze EMBBS
CL
F 6-11-99 Revised Tables CMDEG 10-4-01 Revised Suffix-BS RN
Flapper Type Backwater Valve (Specify Suffix -DV or -EV)Sediment Bucket -BVandal Proof Screws -U
D09PBE09PB
Flapper Type Backwater Valve (Specify Suffix -FV)Holes in Flange -SHSediment Bucket -BVandal Proof Screws -U
JAY R.SMITH MFG. CO.®
DIVISION OF SMITH INDUSTRIES, INC.POST OFFICE BOX 3237MONTGOMERY, ALABAMA 36109-0237 (USA)TEL: 334-277-8520 FAX: 334-272-7396 www.jrsmith.comCUSTOMER
DRIVEN
SMITH®
MEMBER OF:
®
ASPE®
SANITARY
E
NGINEERINGPrevention Rather Than C
ure
FIGURE NUMBER
LOCATIONA
OPTIONAL STRAINER HEADS
Specify Type, Size & Finisheg: H05CP
B DIA 05 (125) 06 (150) 07 (180) 08 (205) H 2 (51) 2 (51) 2 1/4 (57) 2 1/2 (64) MIN 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/2 (38) MAX 2 1/4 (57) 2 1/4 (57) 2 1/4 (57) 2 1/2 (64)
X
SUFFIX -H
SOLID HINGED COVER
FUNCTION: Used in areas where intermittentdrain use is required. Solid cover preventsintrusion of chips, saw-dust, etc., which areswept up before cover is opened for washdown.The secondary strainer prevents debris fromentering the waste line.
H
B
SUFFIX -GSpecify Type, Size & Finish
eg: G08PB
B DIA 05 (125) 06 (150) 08 (205) H 2 (51) 2 (51) 2 1/2 (64) MIN 1 1/4 (32) 1 1/4 (32) 1 1/2 (38)MAX 2 1/4 (57) 2 1/4 (57) 2 1/2 (64)
LOW DOME STRAINER
MATERIALS:Chrome Plated -CPPolished Bronze -PB
FUNCTION: Used in gutters and recessed areas where excessive debris build-up is expected. Dome insures drainage even when partly covered.
H
B
Specify Type, Size & Finisheg: J06NBSUFFIX -J
FUNCTION: Solid gas tight, vandal proof, threaded cover for areas where intermittent drain use is required.