Top Banner
Smith Chart Weimin Peng JWC technologies, Inc. www.jwctech.com (972)207-0917
14

Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

Sep 03, 2019

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

Smith Chart

Weimin Peng

JWC technologies, Inc.

www.jwctech.com

(972)207-0917

Page 2: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

• Smith Chart was developed by P. Smith at the Bell Lab in 1939

• Smith Chart provides an very useful way of visualizing the transmission line phenomenon and matching circuits.

• In this slide, for convenience, we assume the normalized impedance is 50 Ohm.

Page 3: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

Smith Chart and Reflection coefficient

Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert the load impedance to reflection coefficient and vice versa.

Page 4: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

Smith Chart and impedance

Examples:

The upper half of the smith chart is for inductive impedance. The lower half of the is for capacitive impedance.

Page 5: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

Constant Resistance Circle

And the impedance on this circle r = 1 with different inductance (upper circle) and capacitance (lower circle)

This produces a circle where

Page 6: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

More on Constant Impedance Circle

The circles for normalized rT = 0.2, 0.5, 1.0, 2.0 and 5.0 with

Page 7: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

Constant Inductance/Capacitance Circle

Similarly, if xT is hold unchanged and vary the rT

You will get the constant Inductance/capacitance circles.

Page 8: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

Constant Conductance and Susceptance Circle

Reflection coefficient in term of admittance:

And similarly, We can draw the constant conductance circle (red) and constant susceptance circles(blue).

Page 9: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

Example 1: Find the reflection coefficient from input impedance

Example1: Find the reflection coefficient of the load impedance of:

Step 1: In the impedance chart, find 1+2j. Step 2: Measure the distance from (1+2j) to the Origin w.r.t. radius = 1, which is read 0.7 Step 3: Find the angle, which is read 45° Now if we use the formula to verify the result. The result is

Page 10: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

Example 2: Adding an inductor in series with load

Step 1: In the smith chart, find the load Zload

Step 2: Rotate along the constant r circle by the amount of ( ) The terminal point is the input impedance of the inductor in series with the load.

Page 11: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

Summary: Adding inductive/Capacitive Components to the Load

The effect of adding inductive and capacitive component with the load.

Page 12: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

Impedance Matching Example 1

The load is at 0.4 Ω + j1.5 Ω, the reference impedance is 50 Ω. Step 1: Add a serial capacitor to move the impedance to 1 + jx along a constant resistance circle Step 2: Add a parallel inductor to move the impedance to 1 along a constant conductance circle. Note: The matching circuit is a high pass filter

Page 13: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

Impedance Matching Example 2

The load is at 0.4 Ω + j1.5 Ω, the reference impedance is 50 Ω. Step 1: Add a parallel capacitor to move the impedance to 1 + jx along a constant conductance circle Step 2: Add a serial inductor to move the impedance to 1 along a constant resistance circle. Note: The matching circuit is a low pass filter

Page 14: Smith Chart - jwctech.com · Smith Chart and Reflection coefficient Smith Chart is a polar plot of the voltage reflection coefficient, overlaid with impedance grid. So, you can covert

Impedance Matching Example 3

The load is at 0.4Ω + j1.5, the reference impedance is 50 Ω. Step 1: Add a cable to rotate the load admittance to 1 + jb along a constant reflection coefficient circle Step 2: Add a short stud to move the load admittance to 1 along a constant admittance circle. Note: The matching circuit is a low pass filter