SMARTLINCMultiple Lock System
logic module & set-up instructions
AVAILABLE FEATURESMASTER CODE (Factory set to 1-2-3-4-5-6-7-8)• ChangeCode• Enroll/DeleteLocks• Install/DeleteManager• SetLockOptions• ReprogramSoftware• AccesstoMasterMenu• DownloadAudit• SetTimeLockPeriods
MANAGER CODE(Factory set to 1-1-1-1-1-1)• ManagesUsers• ChangeTimeDelayValues• DownloadAudit• ControlTemporaryTimeLock• ExtendOpenPeriod,ifenabled
USER CODE• Uptonineusersperlock,includingManager• OpenLock• ChangeCode• SetImmediateLock
MULTIPLE LOCKS• UptoFive
APB (Auxiliary Power Box)• Mustbeorderedwitheverysystemnomatterhowmanylocks areenrolled• Providesconstantpowertoauditinformationintheeventofprimary (batteryorA/C)powerloss
SENDING SET-UP TO THE LOCKThis function requires the use of the Lock Programming Cable (P/N 43098) and a Serial Interface Connector.1.ConnectpowertothelockviatheLogicModuleorsmall/largebatteryboxthroughtheportonthelockmarkedBAT.TheuseofDuracellTM
orEvereadyTMbatteriesisrecommended(seeFigure1).2.PlugInterfaceandcableintoPCandopenSMARTLINCSet-upSoftware.3.Plugthe43098cableintothelockthroughtheportonthelockmarkedENT.4.SelectthelockIDforthelocktobeprogrammed.ItisagoodideatomarkthelockitselfwithitsIDnumber.5.PresstheSendbuttononthesoftwareandthentheStartbutton(seeScreen7).6.OnthescreenthesoftwarewillscrollthrougheachRecordNumber(1-12)asitdownloadstothelock,thenitwillshowOK.7.Repeatsteps3-6foreachlocktobeprogrammedwiththisconfiguration.NOTE: If the computer does not have a serial port, a serial to USB connector will be required.
CONTROL UNIT (LOGIC MODULE) SET-UPTosetupthelogicmodule,clickontheControlUnitSet-upbuttonontheopeningscreen(seeScreen8).Awindowwiththedefaultconfigurationwillappear(seescreen9).InthiswindowselectthefeaturestobeenabledontheLogicModule. • EncryptioncanbeseteitherONorOFF.ThedefaultissetforOFF.CAUTION: If encryption is set ON, once the locks have been installed to this Logic Module, this will be the only Logic Module able to be used with these locks. • HemisphereissetwithadefaultforNORTH.SelecttheHemispherewheretheunitswillbeactive. • TheDallas®key(eKEYII)optioncanbeselectedonthispage.ChecktheYESbox,thenselectwhichlockstosetupforusewitheKEYII, (seeScreen10). • DelayCountingDisplayissettoadefaultofCountdown.AvailableoptionsaretohaveTimeDelaycountingsequenceCountUp, CountDownorNotDisplayed. • TheTDMINwindowallowstheentryofaminimumTimeDelayvalue.Oncethisnumberisentered,Managershavingaccesstothetime menuwillnotbeabletochangetheTimeDelayvaluebelowthisminimumdelayperiodnumber.ThisfeaturewillprogramALLlockson thesystemthathaveaTimeDelayset-up. • MultipleTimeLockperiodsareavailablebycheckingtheboxmarkedMultiTLActive(seescreen11).IfthereisnocheckintheMultiTL Activebox,anytimelockperiodsprogrammedwillapplytoalllocksenrolledinthesystem.ForadifferentTimeLockperiodtoapplyto aspecificlock,checktheMultiTLActivebox.ThelocksenrolledinthesystemmaybesettoTimeLockperiod1,2orNoTimeLock. • OpenExtensionissettoNObydefault.Withthisoption,noonewillhaveaccesstotheOpenExtensionTimeMenuontheLogic Module.SelectingYESallowstheManagerand/orUsers(asselectedinthenextoption)toaccesstheTimeLockOpenExtensionmenu ontheLogicModule.ThosewhohaveaccesscanthenextendtheTimeLockOpenPeriodin30minuteincrements,butnomorethan twohoursorfour(4)30minuteincrements. • TimeMenuAccessallowsyoutoselectwhetherboththeManagerandtheUsersortheManageronlywillhaveaccesstothe TimeMenu. • TheLockInstallationCode(5-0-5-0-5-0)isusedtoenrollthelockstotheLogicModuleduringSystemSet-upusingtheMasterMenuon theLogicModule.Onceallofthefeaturesforthislockhavebeenselected,savetheset-uptoafileforlateruse.Ifafilehasalreadybeensaved,itmaybeopenedfromthiswindowaswell.
SENDING SET-UP TO THE LOGIC MODULEThis function requires the use of the Logic Module Programming Cable (P/N 43097) and a Serial Interface Connector.1.ConnectpowertotheLogicModule.(Requirestheuseofa9Vbattery.)DuracellTMorEvereadyTMbatteriesarerecommended.2.PlugInterfaceandcableintoPCandopenSMARTLINCSet-upSoftware.3.Connectthe43097cabletotheLogicModulethroughtheportonthekeypad.4.PresstheSendbuttononthesoftware(seeScreen12).5.ThesoftwarewillinstructyoutoactivatethePCLinkintheMasterMenuontheLogicModule(seescreen13).NOTE: This reminder screen will display even if PC Link is already activated.6.PressanykeytopowerupSMARTLINC. • Displaywillshoweither“ENTERCOMBO”or“SELECTLOCK”whentwoormorelocksareinstalled.7.Holddown“zero”untilthedisplayshows“MASTER,X-X-X-X-X-X-X-X”8.EntertheMASTERcode.9.Pressthe“P”buttonfour(4)timestoselectPCLink;thedisplaywillshow“PCLINK”.PresstheOKbuttontostartcommunicationwith thePC.10. OnthescreenthesoftwarewillscrollthrougheachRecordnumberasitdownloads,thenitwillshowOK. • InordertoexitfromPCLink,pressthe“P”buttonthree(3)times.Whenthescreenreads“DoyouwanttoQUIT?”pressthe“OK”button toexit.NOTE: If the computer does not have a serial port, a serial to USB connector will be required.
DST (Daylight Savings Tine) SET-UPThis function requires the use of the Logic Module Programming Cable (P/N 43097), PC, DST Update Software and a Serial Interface Connector.1.Toset-upDST,clickontheDSTicononthePCdesktop.Theset-upwindowwillappear(seeScreen14).Inthiswindow,setuptheDST datesorselectfromthepre-setfilesavailable.Apre-setfilehasbeencreatedfortheUSA.2.ClickFilefromthemenubar,thenOpen.3.SelectthefilemarkedUSA.DATandclickOpen(seeScreen15). • Thedateswillautomaticallybefilledinforthenext15years(seeScreen16).NOTE: This program will also allow the DST file to be deleted from a previously programmed Logic Module in the event the Module must operate in a state not having DST.
SENDING DST (Daylight Savings Tine) SET-UP TO THE LOGIC MODULEThis function requires the use of the Logic Module Programming Cable (P/N 43097), PC, DST Update Software and a Serial Interface Connector.1.ConnectpowertotheLogicModule.(Requirestheuseofa9Vbattery).DuracellTMorEvereadyTMbatteriesarerecommended.2.PlugInterfaceandcableintoPCandthenconnectthe43097cabletotheLogicModulethroughtheportonthekeypad.3.PressanykeytopowerupSMARTLINC. • Displaywillshoweither“ENTERCOMBO”orSELECTLOCK”whentwoormorelocksareinstalled.4.Holddown“zero”untilthedisplayshows“MASTER,X-X-X-X-X-X-X-X”.EntertheMASTERcode.5.Pressthe“P”buttonfour(4)timestoselectPCLink,thedisplaywillshow“PCLINK”6.PresstheSendbuttononthesoftware. • InordertoexitfromPCLink,pressthe“P”buttonthree(3)times.Whenthescreenreads“DoyouwanttoQUIT?”,pressthe“OK” buttontoexit.NOTE: If the computer does not have a serial port, a serial to USB connector will be required.
TIME LOCK SET-UPTosetupTimeLock,clickontheTimeLockbuttonontheopeningscreen(seeScreen8).Awindowwiththedefaultconfigurationwillappear(seeScreen17).Thiswindowallowstheset-upofStandardWeekandSpecialEventsTimeLock.ItispossibletosetuptwodifferentTimeLockperiods.
STANDARD WEEK1.SelectTimeLock1. • Select“Add”,“Delete”or“DeleteAll”byright-clickingthecursorinthefirstlineontheStandardWeekscreen(seeScreen18).2.Select“Add”tosetupthefirstTimeLockperiod.“MONfrom08:00to08:00”willautomaticallybeentered. • ClickingintheDayboxineithertheOpenorClosedareawillproduceascrollmenuforselectingthedayoftheweekfortheTime Lockperiod.3.ToentertheOpenTime,highlighttheTimeboxintheOpenareaandenterthetimeusinga24-hourclock.4.ToentertheClosetime,highlighttheTimeboxintheClosedareaandenterthetimeusinga24-hourclock. • Oncethefirstday’sTimevalueshavebeenentered,youwillbeaskedwhetherornotyouwishtocompletetherestoftheweek(see Screens19and20).NOTE: If the choice is made to not automatically complete the rest of the week, enter the daily Time Lock values in any day order and press the green Step button to sort the records by day.5.SavethisTimeLockconfigurationasTimeLock1andthecompanyname.6.SelectTimeLock2andrepeatsteps2-5.CAUTION: Any day not completed will be considered a day in Time Lock and the units will be unavailable on that day.
SENDING TIME LOCK SET-UP TO THE LOGIC MODULEThis function requires the use of the Logic Module Programming Cable (P/N 43097) and a Serial Interface Connector.1.ConnectpowertotheLogicModule.(Requirestheuseofa9Vbattery.)DuracellTMorEvereadyTMbatteriesarerecommended.2.PlugInterfaceandcableintoPCandopenSMARTLINCSet-upsoftware.3.Connectthe43097cabletotheLogicModulethroughtheportonthekeypad.4.OpenthecorrectfilefortheTimeLockperiod(1or2)thatwillbedownloadedtothislock.5.PresstheSendbuttononthesoftware(seeScreen23). • ThesoftwarewillinstructyoutoactivatethePCLinkintheMasterMenuontheLogicModule(seeScreens23&24).6.PressanykeytopowerupSMARTLINC. • Displaywillshoweither“ENTERCOMBO”orSELECTLOCK”whentwoormorelocksareinstalled.7.Holddown“zero”untilthedisplayshows“MASTER,X-X-X-X-X-X-X-X”8.EntertheMASTERcode.9.Pressthe“P”buttonfour(4)timestoselectPCLink;thedisplaywillshow“PCLINK”.PressOKtostartcommunicationwiththePC.10. OnthescreenthesoftwarewillscrollthrougheachRecordnumberasitdownloads,thenitwillshowOK. • InordertoexitfromPCLink,pressthe“P”buttonthree(3)times.Whenthescreenreads“DoyouwanttoQUIT?”,pressthe“OK” buttontoexit.NOTE: If the computer does not have a serial port, a serial to USB connector will be required.
SPECIAL EVENTS SET-UPTosetupSpecialEvents,clicktheTimeLockbuttonontheopeningscreen(seeScreen8).Awindowwiththedefaultconfigurationwillappear(seeScreen17).Thiswindowallowstheset-upofStandardWeekandSpecialEventsTimeLock.
SPECIAL EVENTS • Byright-clickingwiththecursorinthefirstlineontheSpecialEventsscreen,select“Add”,“Delete”or“DeleteAll”(seeScreen25). • Selectthefirstboxandselect“Add”tosetupthefirstSpecialEventperiod.SelectthecorrectDayandDate(1,July)fromthedrop- downmenufortheClosedTime.ThenselectthecorrectDayandDatefromthedrop-downmenufortheOpenTime(seeScreen26). • UptotwentySpecialEventsmaybeadded(amaximumoffourweeks)foreachyear.NOTE: Special Events will repeat each year on that Calendar date. Floating Holidays, i.e. Thanksgiving, Labor Day, etc. cannot be programmed.
SENDING SPECIAL SET-UP TO THE LOGIC MODULEThis function requires the use of the Logic Module Programming Cable (P/N 43097) and a Serial Interface Connector.1.ConnectpowertotheLogicModule.(Requirestheuseofa9Vbattery.)DuracellTMorEvereadyTMbatteriesarerecommended.2.PlugInterfaceandcableintoPCandopenSMARTLINCSet-upsoftware.3.Connectthe43097cabletotheLogicModulethroughtheportonthekeypad.4.PresstheSendbuttononthesoftware(seeScreen23).5.ThesoftwarewillinstructyoutoactivatethePCLinkintheMasterMenuontheLogicModule(seeScreens23&24).6.PressanykeytopowerupSMARTLINC. • Displaywillshoweither“ENTERCOMBO”orSELECTLOCK”whentwoormorelocksareinstalled.7.Holddown“zero”untilthedisplayshows“MASTER,X-X-X-X-X-X-X-X”8.EntertheMASTERcode.9.Pressthe“P”buttonfour(4)timestoselectPCLink;thedisplaywillshow“PCLINK”.PressOKtostartcommunicationwiththePC.10. OnthescreenthesoftwarewillscrollthrougheachRecordnumberasitdownloads,thenitwillshowOK. • InordertoexitfromPCLink,pressthe“P”buttonthree(3)times.Whenthescreenreads“DoyouwanttoQUIT?”,pressthe“OK” buttontoexit.NOTE: If the computer does not have a serial port, a serial to USB connector will be required.
No Answer• Acommunicationerror(checkcableandbatteryconnectionsand/orre-startSet-upapplication)• CheckCOMportsetting.TryselectingadifferentCOMportandretry.• SMARTLINCisnotinPC-Linkmode(ActivatePCLinkinMastermenu)