Page 1: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

Introduction to Smartcool ECO3

at BOMA Denver Allied Showcase & Conference by Refrigerants Inc. May 14, 2015

Page 2: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

• Smartcool & Refrigerants Inc.

• ECO3 Features & Applications

• How the ECO3 Saves Energy• Savings Calculations• Past Results

Agenda

Page 3: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

Refrigerants Inc. & Smartcool

• Smartcool is a global clean technology company helping some of the world’s largest organizations enhance their profitability, while lowering their carbon footprint.

• Smartcool delivers cutting edge energy efficiency and cost reduction solutions for customers around the world.

• Smartcool’s technology reduces the electricity usage (kWh) and demand (KW) of air conditioning, refrigeration and heat pump systems by improving compressor efficiency.

• Refrigerants Inc. has been Premier Regional Distributor of the Smartcool ECO3 since 2014.

• ECO3s have been successfully deployed on a large number of Refrigerants Inc. projects across the country.

• In that time the Smartcool ECO3 has grown to become an important part of the RI Green Products catalog of energy conservation measures and has augmented the value of the Refrigerants Inc. solution.

• The Refrigerants Inc. team provides superb sales and technical support for the ECO3 with backup support available from Smartcool.

Page 4: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

ECO³™ Features• Enhances cooling performance by optimizing

compressor run times

• Typical usage (kWh) savings of 15%-25%

• Typical payback of 12 – 36 months

• Compatible with existing controls

• Zero risk to current equipment or effect on manufacturer warranty

• Maintains temperature performance

• Digital display to track energy savings & provide diagnostic readings of system performance

• Flexible indoor or outdoor installation

• Smartcool technology has been tested by Oak Ridge National Labs and used in over 30,000 installations worldwide with consistent and exceptional results...

Page 5: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

ECO3 ApplicationsThe ECO3 can be installed on any air conditioning, refrigeration or heat pump system with one or two stages of control.

These compressors are controlled by the ECO3 , which is wired in directly downstream of the controller output for the compressor.

During a save period, the ECO3 either turns off the compressor(s) or delays them from starting, in order to shed compressor capacity and save energy.

Greater energy efficiency is achieved without impacting temperature or humidity in the conditioned space.

Page 6: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

Installation

• Typical electrician’s tool kit• 24 VAC Power Supply (can be 24 VDC)• Fuse (24V/1A) between supply and ECO3

• In-Line fuse per channel: 240V/5A • The ECO3 unit (with user manual, back

plate and quick reference sticker)• An enclosure may be necessary for an

outside installation

Installing the ECO3 typically takes about one hour for a certified installer with no interruption to business operation.

Page 7: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

The Operation of Conventional Cooling Systems• When there is a call for air

conditioning (A/C) or refrigeration, the thermostat simply switches the compressor on to run continuously until the temperature set point is reached. There is no energy management working on system performance.

• When the A/C starts, suction pressure is high, head pressure is low, the evaporator is warm, and the condenser is cold. These are ideal conditions for the compressor to efficiently pump large volumes of cooling refrigerant. Initially, cooling performance is up to 50% above rated system capacity. After a short period, conditions reverse and cooling capacity declines to minimum rated value.

Page 8: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

Smartcool Solution to Enhance Cooling System Performance

What It Does•The A/C starts with a thermostat call, but instead of the inefficiency of a conventional cooling cycle, Smartcool software and microprocessor continuously monitors and evaluates real-time demand trends. Then, employing sophisticated energy management strategies, the cooling system is cycled, within manufacturer specifications, to maintain near maximum capacity. Performance is maintained up to a 50% increase over rated capacity typically resulting in 10-20% and up to 30% reduced system run-time, all the while maintaining temperature requirements.

How It Does It•Smartcool does not allow system performance to erode to rated capacity. Before that can occur, Smartcool, using its predictive algorithms, shuts off and “rests” the compressor for typically 6 to 12 minutes each control period. Upon each restart, the cooling system naturally resumes high capacity mode until the thermostat is satisfied.

Page 9: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

Smartcool Websites –

www.smartcooleco3.com • Website

focused on the ECO3 product line, includes:

• Product Information

• FAQs

• Instructional Videos

• Savings Calculator

• Case Studies

Page 10: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

Smartcool Websites –

www.smartcool.net • Smartcool

corporate website, includes:

• Company Information

• Product Information

• Distributor Listing

• Password Protected ‘Distribution Network Support Library’

Page 11: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

• Facebook https://www.facebook.com/SmartcoolSystems

• LinkedIn http://www.linkedin.com/company/1416672?trk=NUS_CMPY_TWIT

• Twitter https://twitter.com/SmartcoolNews.

Social Media

Page 12: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

Videos

http://www.youtube.com/user/SmartcoolGlobal

• Available videos, include:

• ‘How the ECO3 Saves Energy’

• ‘How to Check Savings on the ECO3’

• ‘ECO3 Savings Calculator Demonstration’

• Media coverage from around the world

Page 13: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

ECO3 Demo Kit

Page 14: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

ECO3 Demo Kit

Page 15: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

ECO3 Demo Kit

Page 16: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

Savings Calculations

• Savings percentage achieved can be calculated using information available on the ECO3 display screen. Number of save hours as a percentage of total hours indicates savings:

Save Hours ÷ (Run Hours + Save Hours + Automatic Override Hours)

• Unit load factors can be calculated using information available on the ECO3 display screen and the total logging period hours:

(Run Hours + Save Hours + Manual Bypass Hours + Automatic Override Hours) ÷ Elapsed Time

• Seasonal Adjustment Factor can be calculated using historical cooling degree day (CDD) & heating degree day (HDD) data for the test location. The annual savings calculations for A/C can be seasonally adjusted by multiplying the savings percentage (calculated above) by the historical A/C load factor for the test period divided by the historical avg. annual load factor for the test location:

Historical Load Factor for test period / Historical Avg. Annual Load Factor for test location

• Annual kWh savings can be calculated by multiplying the savings percentage (calculated above) times the rated kW consumption (collected in site survey) of the compressor times unit load factor (calculated above) times seasonal adjustment factor (calculated above):

Savings Percentage * Compressor Rated KW * Unit Load Factor * Seasonal Adjustment

Page 17: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

• Savings can be shown by entering screen data into on-line savings calculator http://www.smartcooleco3.com/the-eco3/savings-calculator with your smart phone (via QR code)

• There is also a ‘how to’ video.

Savings Calculation – On-Line Calculator

Page 18: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

Sample Savings & Economics at 3 Big Box Retail Stores in California

Colton•21 Lennox A/C Units

• Five * 13 Tons• Fifteen * 10 Tons• One * 3 Tons

•Est. Annual Savings:

• 145,555 kWh• $20,378

•Est. Economics:• 43.8% ROI• 27.4 Month

Payback

Victorville•16 Lennox A/C Units

• Four * 13 Tons• Seven * 12.5

Tons• Four * 10 Tons• One * 4 Tons

•Est. Annual Savings:

• 121,435 kWh• $17,001

•Est. Economics:• 48.1% ROI• 24.9 Month

Payback•

Palm Desert•8 York A/C Units

• Six * 20 Tons• One * 12.5 Tons

•Est. Annual Savings:

• 106,986 kWh• $14,978

•Est. Economics:• 83.6% ROI• 14.4 Month

Payback

Page 19: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

Allentown Service PlazaType A Prototype, 22,200 SF, built in May 2008

•9 A/C & 6 Refrigeration units optimized with 8 ECO3-Singles & 7 ECO3-Duals

•Avg. Refrigeration Savings: 33.25%•Avg. A/C Savings: 17.58%

Sample Savings & Economics at 2 Restaurant & Convenience Store Plazas in Pennsylvania

King of Prussia Service PlazaType B Prototype, 14,820 SF, built May 2010

• 8 A/C & 5 Refrigeration units optimized with 9 ECO3-Singles & 4 ECO3-Duals

• Avg. Refrigeration Savings: 42.91%

• Avg. A/C Savings: 18.08%

Annual Energy Savings kWhAnnual Financial Savings

Initial Capital OutlayReturn On Investment

Pay Back Period months62%19

96,975

$11,967$19,215

Annual Energy Savings

56,280 kWh

Annual Financial Savings

$6,945  

Initial Capital Outlay $16,758  Return On

Investment41%  

Pay Back Period 29 months

Page 20: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

Who Uses Smartcool’s Technology?

Page 21: Smartcool ECO3 Presentation - Refrigerants Inc - BOMA Denver - May 14 2015

Thank You for Your Time!

Questions?.....