Top Banner
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore-570 008 Mob: 9342188467 Email: [email protected]
40
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • *Design and drawing of RC StructuresCV61Dr. G.S.SureshCivil Engineering DepartmentThe National Institute of EngineeringMysore-570 008Mob: 9342188467Email: [email protected]

  • *DETAILING OF BEAM &SLAB

  • *Learning out ComeReview of detailing of beamsContinuous rectangular beamsCantilever rectangular beamsFlanged beamsIntroduction to detailing of slabOne way slab

  • *

  • *PROBLEM No. 3 Draw the Longitudinal section and two cross sections one near the support and other near the mid span of a RCC continuous beam with the following data:Clear span of beams = 3m eachWidth of beam = 200mmOverall depth of beam = 300mmWidth in intermediate supports = 200 mmMain reinforcement = 4 Nos -12 mm diameter bars with 2 bars bent upAnchor/hanger bars= 2-10 mm diameterStirrups = 6 mm diameter @ 300 mm c/c.Materials : HYSD bars and M20 grade concrete

  • *PROBLEM No. 3

  • *PROBLEM No. 4 A rectangular beam of cross section 300 x 450 mm is supported on 4 columns which are equally spaced at 3m c/c. The columns are of 300 mm x 300 mm in section. The reinforcement consists of 4 bars of a6 mm diameter (+ve reinforcement) at mid span and 4 bars of 16 mm diameter at all supports (-ve reinforcement). Anchor bars consists of a 2-16 mm diameter. Stirrups are of 8 mm diameter 2 legged vertical at 200 c/c throughout. Grade of concrete is M20 and type of steel is Fe 415. Draw longitudinal section and important cross sections.

  • *PROBLEM No. 4

  • *

  • *PROBLEM No. 5 Draw to scale of 1:20 the Longitudinal section and two cross-section of a cantilever beam projecting 3.2 from a support using following dataClear span=3.2mOverall depth at free end= 150 mmOverall depth at fixed end= 450 mmWidth of cantilever beam= 300 mm Main steel = 4-28 mm dia with two bars curtailed at 1.5m from supportAnchor bars= 2 Nos. 16 mm diaNominal stirrups = 6mm dia at 40 mm c/cBearing at fixed end = 300 mmUse M20 concrete and Fe 415 steel

  • *PROBLEM No. 5

  • *PROBLEM No. 6A cantilever beam with 3.2m length is resting over a masonry wall and supporting a slab over it. Draw to a suitable scale Longitudinal section, two cross-sections and sectional plan with the following data:Size of beam = 300 mm x 350 mm at free end and 300 mm x 450 mm at fixed end and in the wall up to a length of 4.8m Main steel: 4 nos. of 25 mm dia bars, two bars curtailed at 1.2m from free endHanger bars: 2 nos. 16mm.Stirrups: 6mm dia 2 legged stirrups @ 200 mm c/c the support length and @100 mm c/c from fixed end up to length of 1m @ 150mm c/c up to curtailed bars and remaining @ 200 c/c. Use M20 concrete and Fe 415 steel

  • *PROBLEM No. 2

  • *

  • *PROBLEM No. 7 A beam has following dataClear span = 4mSupport width = 300mmSize of web = 350 x 400 Size of flange = 1200 x 120mm Main reinforcement in two layers : 3-20 tor + 3-16 tor and to be curtailed at a distance 400 mm from inner face of support Hanger bars: 3- 20 torStirrups: 2L-8 tor @ 200 c/cUse M20 concrete and Fe 415 steelDraw longitudinal and cross section if the beam isT-beamInverted T-beamL-Beam

  • *PROBLEM No. 5

  • *

  • Dr.G.S.Suresh*IntroductionUsed for covering spaces in the form of roof or floor Slab may be supported on walls or beams or columns . Slab supported directly by columns are called flat slab One Way Slab Two Way Slab

    Dr.G.S.Suresh

  • Dr.G.S.Suresh*IntroductionSlabs could be simply supported, continuous or cantilever In two way slab the corners may be held down by restraints or may be allowed to lift up Additional torsion reinforcement is required at corners when it is restrained against uplifting as shown in Fig

    Dr.G.S.Suresh

  • Dr.G.S.Suresh*Introduction

    Dr.G.S.Suresh

  • Dr.G.S.Suresh*IntroductionThickness of the slab is decided based on span to depth ratio specified in IS456-2000. Min reinforcement is 0.12% for HYSD bars and 0.15 % for mild steel bars. The maximum diameter of bar used in slab should not exceed 1/8 of the total thickness of slab Maximum spacing of main bar is restricted to 3 times effective depth or 300 mm which ever is less For distribution bars the maximum spacing is specified as 5 times the effective depth or 450 mm which ever is less

    Dr.G.S.Suresh

  • Dr.G.S.Suresh*IntroductionGenerally 15 mm to 20 mm cover is provided for the main reinforcements Alternate main bars can be cranked near support or could be bent at 1800 at the edge and then extended at the top inside the slab as shown in Fig Curtailment and cranking of bars and is shown in Fig

    Dr.G.S.Suresh

  • Dr.G.S.Suresh*Introduction

    Dr.G.S.Suresh

  • Dr.G.S.Suresh*IntroductionTorsion Reinforcement shall be provided as shown in Fig.

    Dr.G.S.Suresh

  • Dr.G.S.Suresh*Torsion Reinforcement

    Dr.G.S.Suresh

  • Dr.G.S.Suresh*Torsion Reinforcement

    Dr.G.S.Suresh

  • Dr.G.S.Suresh*Typical One Way slab

    Dr.G.S.Suresh

  • Dr.G.S.Suresh*Typical Two Way slab

    Dr.G.S.Suresh

  • *PROBLEM Prepare a detailed structural drawing of one way continuous slab for a hall of clear dimensions 7m wide and 11.77 m long, use following dataCentre to centre distance of supporting beams = 3.0 mSpan of the beams = 7.23mBeams are supported on walls of 0.23 m thicknessC/s of beam = 230 x 450 mmGrade of concrete : M20Type of steel : Fe415Clear cover : 20 mmSlab thickness: 150 mmBeam depth is inclusive of slab depth, The hall is having walls on all 4 sides

  • *PROBLEM Main positive reinforcement @ end span = 8mm diameter @100 c/cMain reinforcement in other interior panels = 8 mm diameter @ 200 c/cNegative reinforcement @ all supports = 8mm diameter @ 200 c/cDistribution steel= 8mm diameter @ 200 c/c

  • *PROBLEM

  • *

  • *No. 1

  • *No. 2

  • *No. 3

  • *No. 4

  • *No. 5

  • *Do it Yourself 1. Draw the longitudinal section and typical cross sections ( at centre and support), and show the reinforcement details in a simply supported rectangular beam of size 300 mm x 500 mm, clear span 5m supported on walls of 0.3m, use a suitable scale Reinforcements: Main: 4 No. 16mm dia with 2 No. cranked at 1m from centre of support. Stirrup holders 2 Nos. of 12 mm dia Stirrups: 2 legged 8 mm dia stirrups at 250 mm c/c in the central 2m span and 2 legged 8 mm dia stirrups at 150 mm c/c in the remaining portion. Assume concrete M 20 grade and steel Fe 415, and suitable cover. Prepare the bar bending schedule and calculate quantity of steel and concrete required.

  • *Do it Yourself 2. Prepare the bar bending schedule and estimate quantity of steel and concrete after drawing the longitudinal and cross section. Other details are Span of beam = 4.2 mCross section at support end 300 x 600 mm and cross section at free end 300 x 150 mmReinforcements:Main tension steel: 4-20 mm dia, 2 bars are curtailed at a distance of 2m from free endHanger bars: 1-12 mm diaTwo legged stirrups 8mm dia @ 140 mm c/c for full length.

  • *Dr. G.S.SureshCivil Engineering DepartmentThe National Institute of EngineeringMysore-570 008Mob: 9342188467Email: [email protected]

    ****************************************