ZXSDR B8200 W100WiMAX Baseband
Commissioning and DataConfiguration Manual
Version 4.02
ZTE CORPORATIONNO. 55, Hi-tech Road South, ShenZhen,
P.R.ChinaPostcode: 518057Tel: (86) 755 26771900Fax: (86) 755
26770801URL: http://ensupport.zte.com.cnE-mail:
[email protected]
-
LEGAL INFORMATION
Copyright 2010 ZTE CORPORATION.
The contents of this document are protected by copyright laws
and international treaties. Any reproduction or distribution ofthis
document or any portion of this document, in any form by any means,
without the prior written consent of ZTE CORPO-RATION is
prohibited. Additionally, the contents of this document are
protected by contractual confidentiality obligations.
All company, brand and product names are trade or service marks,
or registered trade or service marks, of ZTE CORPORATIONor of their
respective owners.
This document is provided as is, and all express, implied, or
statutory warranties, representations or conditions are
dis-claimed, including without limitation any implied warranty of
merchantability, fitness for a particular purpose, title or
non-in-fringement. ZTE CORPORATION and its licensors shall not be
liable for damages resulting from the use of or reliance on
theinformation contained herein.
ZTE CORPORATION or its licensors may have current or pending
intellectual property rights or applications covering the
subjectmatter of this document. Except as expressly provided in any
written license between ZTE CORPORATION and its licensee,the user
of this document shall not acquire any license to the subject
matter herein.
ZTE CORPORATION reserves the right to upgrade or make technical
change to this product without further notice.
Users may visit ZTE technical support website
http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE
CORPORATION.
Revision History
Revision No. Revision Date Revision Reason
R1.0 08/30/2010 First edition
Serial Number: SJ-20100712162153-003
-
Contents
About This Manual.............................................
I
Declaration of RoHS Compliance ....................... I
Overview...........................................................1Typical
Configuration.......................................................
1
Position in the
Network.................................................... 1
Connection Mode between ZXSDR B8200 W100 and
AGW.....................................................................
3
Connection Mode between ZXSDR B8200 W100 and
RRU......................................................................
4
Basic Data Configuration
...................................5Physical Configuration
..................................................... 5
Physical Configuration
Flow.......................................... 5
Configuring Global Parameters
..................................... 6
Adding a
B8200.........................................................11
Configuring the BBU Basic Information
.........................13
Adding a BBU Rack
....................................................16
Adding
Boards...........................................................17
Configuring the CC Work Mode
....................................18
Configuring the XBP Work
Mode...................................19
Configuring the Receivable Mode on CC
........................20
Configuring the BTS External
IP...................................21
Configuring the XBP Parameters
..................................22
Configuring the XBP R6 External IP Address
..................23
Configuring the (Fiber) Connection between BBU and
RRU
................................................................25
Radio Configuration
.......................................................27
Radio Configuration Flow
............................................27
Configuring the QoS Priority for the R6 Port
..................27
Configuring a Cell
......................................................30
Configuring a
Carrier..................................................31
Configuring a
Segment...............................................32
Confidential and Proprietary Information of ZTE CORPORATION
I
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
Managing the BTS
Status................................................35
Synchronizing
Data........................................................37
Figures
............................................................39
Tables
.............................................................41
Index
..............................................................43
Glossary
..........................................................45
II Confidential and Proprietary Information of ZTE
CORPORATION
-
About This Manual
Purpose Thank you for choosing WiMAX radio network system of ZTE
Cor-poration!
ZXSDR B8200 W100 is the WiMAX baseband pool of the WiMAXseries
products. ZXSDR B8200 W100 and RRU form a completeBS, implementing
radio transmission of the covered area, control-ling radio channels
and communicating with the AGW.
ZXSDR B8200 W100 mainly implements channel processing.
Thismanual introduces data configuration for commissioning
ZXSDRB8200 W100.
The intended audience of this manual are
IntendedAudience
This document is intended for commissioning and maintenance
en-gineers of ZXSDR B8200 W100.
Prerequisite Skilland Knowledge
To use this document effectively, users should have a general
un-derstanding of wireless telecommunications technology.
Familiar-ity with the following is helpful:
ZXSDR B8200 W100 hardware structure and working principle
NetNumen M3 (WiMAX OMC-B)
What is in ThisManual
This manual contains the following contents.
Chapter Summary
Chapter 1 Overview Introduces the networkingof ZXSDR B8200 W100
andother devices and the typicalconfiguration.
Chapter 2 Basic DataConfiguration
Introduces the basic configurationfor commissioning ZXSDRB8200
W100, including physicalconfiguration, radio configuration,BS
status management, and datasynchronization.
Conventions ZTE documents employ the following typographical
conventions.
Typeface Meaning
Italics References to other manuals and documents.
Quotes Links on screens.
Bold Menus, menu options, function names, input fields,radio
button names, check boxes, drop-down lists,dialog box names, window
names.
CAPS Keys on the keyboard and buttons on screens andcompany
name.
Confidential and Proprietary Information of ZTE CORPORATION
I
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
Typeface Meaning
Note: Provides additional information about a certaintopic.
Checkpoint: Indicates that a particular step needs tobe checked
before proceeding further.
Tip: Indicates a suggestion or hint to make thingseasier or more
productive for the reader.
Mouse operation conventions are listed as follows:
Typeface Meaning
Click Refers to clicking the primary mouse button (usually
theleft mouse button) once.
Double-click
Refers to quickly clicking the primary mouse button(usually the
left mouse button) twice.
Right-click Refers to clicking the secondary mouse button
(usuallythe right mouse button) once.
II Confidential and Proprietary Information of ZTE
CORPORATION
-
Declaration of RoHSCompliance
To minimize the environmental impact and take more
responsibil-ity to the earth we live, this document shall serve as
formal decla-ration that ZXSDR B8200 W100 manufactured by ZTE
CORPORA-TION are in compliance with the Directive 2002/95/EC of the
Eu-ropean Parliament - RoHS (Restriction of Hazardous
Substances)with respect to the following substances:
Lead (Pb)
Mercury (Hg)
Cadmium (Cd)
Hexavalent Chromium (Cr (VI))
PolyBrominated Biphenyls (PBBs)
PolyBrominated Diphenyl Ethers (PBDEs)
The ZXSDR B8200 W100 manufactured by ZTE CORPORATION meetthe
requirements of EU 2002/95/EC; however, some assembliesare
customized to client specifications. Addition of
specialized,customer-specified materials or processes which do not
meet therequirements of EU 2002/95/EC may negate RoHS compliance of
theassembly. To guarantee compliance of the assembly, the need
forcompliant product must be communicated to ZTE CORPORATION
inwritten form. This declaration is issued based on our current
levelof knowledge. Since conditions of use are outside our control,
ZTECORPORATION makes no warranties, express or implied, and
assumesno liability in connection with the use of this
information.
Confidential and Proprietary Information of ZTE CORPORATION
I
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
This page is intentionally blank.
II Confidential and Proprietary Information of ZTE
CORPORATION
-
C h a p t e r 1
Overview
Table of ContentsTypical
Configuration...........................................................
1Position in the Network
....................................................... 1Connection
Mode between ZXSDR B8200 W100 and AGW ........ 3Connection Mode
between ZXSDR B8200 W100 and RRU......... 4
Typical ConfigurationZXSDR B8200 W100 can be configured with one
or two PMs, oneSA, one or two CCs, one to three XBPs and one
FA.
Figure 1 illustrates the typical configuration of ZXSDR
B8200W100.
FIGURE 1 TYPICAL CONFIGURATION
Position in the NetworkFigure 2 illustrates the position of
ZXSDR B8200 W100 in theWiMAX network.
Confidential and Proprietary Information of ZTE CORPORATION
1
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
FIGURE 2 POSITION IN THE WIMAX NETWORK
Table 1 describes the meanings of the NEs as shown in Figure
2.
TABLE 1 NE MEANING DESCRIPTION
NE Meaning
MS Mobile Station
RRU Remote Radio Unit
B8200 BaseBand Unit 8200
AGW ASN GateWay
CSN Connectivity Service Network
R1 Reference Point 1 protocol interface between MSand BS
R3 Reference Point 3 protocol interface betweenAGW and CSN
R6 Reference Point 3 protocol interface betweenAGW and BS
OBSAI Open Base Station Architecture Initiative
ZXSDR B8200 W100 is an independent baseband processing prod-uct.
Located between AGW and RRU, it constitutes a complete BSwith
RRU.
2 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 1 Overview
Connection Mode betweenZXSDR B8200 W100 andAGWZXSDR B8200 W100
and AGW are connected through the R6 in-terface. Physically, E1/T1
and GE Ethernet interface are adoptedfor the connection.
Figure 3 shows the networking mode and Table 2describe
themeanings of modules.
FIGURE 3 NETWORKING OF ZXSDR B8200 W100 AND AGW
TABLE 2 MODULE MEANINGS DESCRIPTION
Module Meanings
BBU 8200 BaseBand Unit
AGW ASN Gateway
E1/T1 E1/T1 Channel
Ethernet Ethernet Channel
TDM Network Time Division Multiplexing Switching Network
IP IP Network
Confidential and Proprietary Information of ZTE CORPORATION
3
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
Connection Mode betweenZXSDR B8200 W100 andRRUFibers are used to
connect the XBP module of ZXSDR B8200 W100to the RRU, as shown in
Figure 4.
FIGURE 4 NETWORKING OF ZXSDR B8200 W100 AND RRU
4 Confidential and Proprietary Information of ZTE
CORPORATION
-
C h a p t e r 2
Basic Data Configuration
Table of ContentsPhysical Configuration
......................................................... 5Radio
Configuration
...........................................................27Managing
the BTS
Status....................................................35Synchronizing
Data............................................................37
Physical Configuration
Physical Configuration Flow
Figure 5 shows the physical configuration flow of ZXSDR
B8200W100.
Confidential and Proprietary Information of ZTE CORPORATION
5
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
FIGURE 5 PHYSICAL CONFIGURATION FLOW
Configuring Global Parameters
Short Description Global Parameters take effect for all nodes in
the office that canbe used by different BTSs in different
districts.
Prerequisites You must have logged in to the OMC and have the
configurationrights.
Context Global Parameters Configuration include:
Configure AGW
6 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
Configure Downlink Frequency
Configure Foreign BS
Configure Paging Group
Configure OMC IP
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view, as shown in Figure 6.
FIGURE 6 CONFIGURATION MANAGEMENT VIEW
2. Click the OMM_WiMAX node, and the Global
ParametersConfiguration window is displayed in the right pane, as
shownin Figure 7.
FIGURE 7 GLOBAL PARAMETER CONFIGURATION
Confidential and Proprietary Information of ZTE CORPORATION
7
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
Note:
Buttons on Toolbar in Global Parameters Configuration win-dow is
disabled as a default status. Click button to enablethe buttons and
menu if you are ready to do the configuration.
3. Configure AGW.
In the enabled Global Parameters Configuration window,select AGW
tab. Click button or right-click a null data recordand select Add
to display the Add AGW dialog box as shownin Figure 8.
FIGURE 8 ADD AGW
Set AGW ID, Alias, AGW IP, AGW Profile and click OK toadd a AGW
record.
Note:
After the AGW records are added, the parameters take ef-fect for
all nodes in the office. The BTS in the districts adopta global AGW
through the AGW tab of segment. A BTS canadopt multiple Base
Transceiver Station and you can setthe priorities. A maximum of 32
AGWs can be added.
If not necessary, it is recommended that R6 shake param-eters,
NGW version be set to the given default value.
4. Configure Downlink Frequency.
8 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
In the enabled Global Parameters Configuration window,select
Downlink Frequency tab. Click button or right-clicka null data
record and select Add to display the Add DownlinkFrequency dialog
box as shown in Figure 9.
FIGURE 9 ADD DOWNLINK FREQUENCY
According to your planning, set Downlink Frequency andclick OK
to add a Downlink Frequency record. More than onerecord can be
added.
Note:
You can select a downlink frequency record to a carrier
whendoing radio configuration.
5. Configure Foreign BS.
In the enabled Global Parameters Configuration window,select
Foreign BS tab. Click button or right-click a null datarecord and
select Add to display the Add Foreign BS dialogbox as shown in
Figure 10.
Confidential and Proprietary Information of ZTE CORPORATION
9
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
FIGURE 10 ADD FOREIGN BS
According to the information of foreign BS, finish the
parame-ters. And BS ID, BS Alias, Downlink frequency is
required.Click OK to add a Foreign BS record. More than one record
canbe added.
6. Configure Paging Group.
In the enabled Global Parameters Configuration window,select
Paging Group tab. Click button or right-click a nulldata record and
select Add to display the Add Paging Groupdialog box as shown in
Figure 11.
FIGURE 11 ADD PAGING GROUP
Set Paging group ID,MAC hash skip threshold, Responsewindow and
click OK to add a Paging Group.
10 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
Note:
MAC hash skip threshold indicate the maximum of MSsin the
consecutive foreign BS broadcast messages. Validvalue range is 0 ~
255, use default value is recommended.
Value of Response window indicate beginning position ofthe next
response frame of MS after received the broadcastmassages. Valid
value range is 5~ 255, use default valueis recommended.
You can select the Paging Group that a segment is belongto in
the radio configuration.
7. Configure OMC IP.
In the enabled Global Parameters Configuration window,select OMC
IP tab. Click button or right-click a null datarecord and select
Add to display the Add OMC-IP dialog boxas shown in Figure 12.
FIGURE 12 ADD OMC-IP
Select a OMCIP ID from the drop-down list and set OMC IPto add a
OMC IP.
Note:
Indicate a IP address of OMC which OMM report to.
END OF STEPS
Result Configured global parameters records will shown in each
tabs andcan be modified or deleted.
Adding a B8200
Prerequisites You must have logged in to the OMC and have the
configurationrights.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
Confidential and Proprietary Information of ZTE CORPORATION
11
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
2. Right-ClickOMM_WiMAX node and select Add District to dis-play
a Add District dialog box as shown in Figure 13.
FIGURE 13 ADD DISTRICT
3. Set Alias and click OK to create a district node.
4. In the Configuration Management view, expand the
config-uration tree in the left pane. Select the created District
node,right-click and choose Add WBTS > Add SDR to display theAdd
BTS dialog box, as shown in Figure 14.
FIGURE 14 ADDING A BTS
5. In the Add BTS dialog box, according to your planning,
selecta system ID, set BTS type to B8200, set System alias
andExtended attribute, and then click OK.
Note:
The system ID uniquely identifies an B8200. The valid rangeis
2048~4499.
END OF STEPS
Result After you add a B8200 NE, the B8200 node is displayed
under theDistrict node.
12 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
Configuring the BBU BasicInformation
Prerequisites You must have logged in to the OMC and have the
configurationrights.
The B8200 NE must be created.
Steps 1. Click Views > Configuration Management to display
theConfiguration Management view.
2. In the left pane of the Configuration Management, expandthe
configuration tree to the Physical Configuration node un-der the
B8200. The Physical Configuration window is dis-played in the right
pane, as shown in Figure 15.
FIGURE 15 PHYSICAL CONFIGURATION
3. Configure Physical Parameter.
Click the Physical Parameter tab, set the local time zone
andwhether to adopt the Daylight Saving Time (DST).
4. Configure CPU Overload Threshold.
Select CPUOverload Threshold tab and the record list of
CPUoverload threshold for each board will be shown. Double-Clicka
Record or Right-Click and select Modify to define the valuesfor
your own customized configuration as shown in Figure 16.
Confidential and Proprietary Information of ZTE CORPORATION
13
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
FIGURE 16 CPU OVERLOAD THRESHOLD CONFIGURATION
Note:
CPU Overload Threshold record list showed the records for
theboards already added. Low threshold value, High thresholdvalue,
Reset temperature value is setting to 80%, 90%, 100as default. If
the BBU boards havent added yet the thresholdlist would got no
records.
5. Configure Static Route.
Select Static Route tab. Click button or right-click a nulldata
record and select Add to display the Add Static Routedialog box as
shown in Figure 17.
FIGURE 17 ADD STATIC ROUTE
According to the network plan, set Destination subnet, Sub-net
mask, Next hop as shown in Table 3. Click OK to add astatic route.
More than one static route can be added.
14 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
TABLE 3 STATIC ROUTE CONFIGURATION DESCRIPTION
Parameter Configuration Description Example
Destinationsubnet
Destination network which BBUwill route to, AGW network
forexample
10.89.51.0
Subnet mask According to the network plan 255.255.255.0
Next hop It must be in the same networksegment as the XBP R6
IPaddress
10.87.51.1
6. Configure OMC VLAN.
Select OMC VLAN tab as shown in Figure 18.
FIGURE 18 OMC VLAN
OMC VLAN is used to divide the network management mes-sage and
the service message. After enabled this functionfrom OMC uplink
VLAN tag enable drop-down list, uplinkmessages will add a VLAN ID
field which indicated in the OMCVLAN ID. The valid range of VLAN ID
is 11 ~ 4095. Also,you can set the 802.1p priority in OMC VLAN
priority. Forexample, if OMC VLAN priority is setting to a small
number,messages from this VLAN ID port will be put into a low
priorityqueue.
Confidential and Proprietary Information of ZTE CORPORATION
15
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
Caution:
It is cautious to modify OMC VLAN configuration. The
modifi-cation will cause a reset of MAC. Saving the configuration
datain advance is recommended.
END OF STEPS
Result All configured informations will shown in each tab.
Adding a BBU Rack
Prerequisites You must have logged in to the OMC and have the
configurationrights.
The B8200 NE must be created.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. In the left pane of the Configuration Management view,
ex-pand the configuration tree and select the Physical
Configu-ration node under the B8200 node.
3. Right-click the Physical Configuration node and choose AddBBU
Rack to display the Add B8200 W100 Rack dialog box,as shown in
Figure 19.
FIGURE 19 ADDING A BBU RACK
4. Set Rack type, Installation mode and then click OK to adda
BBU rack.
END OF STEPS
Result After you add a B8200 rack, the BBU Rack node is
displayed underthe Physical Configuration node of the B8200 on the
configura-tion tree.
16 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
Adding Boards
Prerequisites You must have logged in to the OMC and have the
configurationrights.
The B8200 rack must be created.
Context ZXSDR B8200 W100 supports two types of module height:
full-height and half-height. Full-height modules include CC and
XBP.Half-height modules include PM, SA, and SE. A typical
configura-tion is used here to illustrate the configuration
process.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. In the Configuration Management view, expand the
config-uration tree, and then select the B8200, Physical
Configu-ration and required BBU rack node.
3. On the B8200 W100 rack that is displayed in the right
pane,add boards.
i. On the required slot, right-click and choose Add Board,and
then select the required board type, as shown in Figure20.
FIGURE 20 ADDING A BOARD
ii. Add the other boards until all the required boards
areadded.
END OF STEPS
Result Added boards showed in Figure 21.
FIGURE 21 ADDING BOARD COMPLETE
Confidential and Proprietary Information of ZTE CORPORATION
17
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
Note:
Different color of boards means different configuration
status.
Configuring the CC Work Mode
Prerequisites You must have logged in to the OMC and have the
configurationrights.
B8200 Rack and CCA board must be created.
Context CC Work Mode is the duplex mode of the BTS network port
whichincluding Network auto adapt/network auto negotiationmode
(default value) and forcedly full duplex mode.
In Network auto adapt/network auto negotiation mode, CCwill
consult with the opposite before establish a duplex mode;
inforcedly full duplex mode, CC will be forced to full duplex
modein communication sessions.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. In the Configuration Management view, expand the
config-uration tree, and then select the B8200, Physical
Configu-ration and required BBU rack node.
3. On the B8200 W100 rack that is displayed in the right
pane,right-click the CCA board and select Configure Work Modeand
the Configure Work Mode dialog box will display asshown in Figure
22.
FIGURE 22 CONFIGURE WORK MODE
4. Select the mode of the network interface from
theWorkmodedrop-down list.
END OF STEPS
Result Changed work mode will take effect from the next net
session.
18 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
Configuring the XBP Work Mode
Prerequisites You must have logged in to the OMC and have the
configurationrights.
B8200 Rack and XBP board must be created.
Context XBP Work Mode is the duplex mode of the R6 port which
includingNetwork auto adapt/network auto negotiationmode
(defaultvalue) and forcedly full duplex mode.
In Network auto adapt/network auto negotiationmode, XBPwill
consult with the opposite before establish a duplex mode;
inforcedly full duplexmode, XBP will be forced to full duplex
modein communication sessions.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. In the Configuration Management view, expand the
config-uration tree, and then select the B8200, Physical
Configu-ration and required BBU rack node.
3. On the B8200 W100 rack that is displayed in the right
pane,right-click the XBP board and select Configure Work Modeand
the Configure Work Mode dialog box will display asshown in Figure
23.
FIGURE 23 CONFIGURE WORK MODE
4. Select work mode of the R6 interface from the Work
Modedrop-down list
END OF STEPS
Result Changed work mode will take effect from the next net
session.
Confidential and Proprietary Information of ZTE CORPORATION
19
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
Configuring the Receivable Mode onCC
Prerequisites You must have logged in to the OMC and have the
configurationrights.
B8200 Rack and CCA board must be created.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. In the Configuration Management view, expand the
config-uration tree, and then select the B8200, Physical
Configu-ration and required BBU rack node.
3. On the B8200 W100 rack that is displayed in the right
pane,right-click the CCA board and select Configure ReceivableMode
and the Configure Receivable Mode dialog box willdisplay as shown
in Figure 24.
FIGURE 24 CONFIGURE RECEIVABLE MODE
4. Select the mode of the antenna from the Work mode drop-down
list.
Note:
CC Board antenna system has 4 different receivable mode
in-cluding GPS mode, GLONASS mode, GPS+GLONASS mode,TRIONES mode.
GPS: Global Positioning System; GLONASS:Global Navigation Satellite
System; TRIONES: Positioning Sys-tem of TRIONES of China.
END OF STEPS
20 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
Configuring the BTS External IP
Prerequisites You must have logged in to the OMC and have the
configurationrights.
The B8200 rack must be created, and the CC board must
beconfigured.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. In the left pane of the Configuration Management view,
ex-pand the configuration tree, and then select the BBU Racknode
under the Physical Configuration node of the B8200.
3. In the BBU rack view, right-click the CCA board and
chooseConfigure BTS External IP to display the Configure
BTSExternal IP dialog box, as shown in Figure 25.
FIGURE 25 CONFIGURING THE BTS EXTERNAL IP
4. According to the network plan, set the external IP
address,mask, next hop, and description, as shown in Table 4.
TABLE 4 BTS EXTERNAL IP ADDRESS DESCRIPTION
Parameter Description Example
External IP It is the IP addressthrough which theCC
communicateswith the OMC. Itneeds to be setaccording to thenetwork
plan.
10.50.2.10
Confidential and Proprietary Information of ZTE CORPORATION
21
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
Parameter Description Example
IP mask It needs to be setaccording to thenetwork plan.
255.255.0.0
Next hop It must be in thesame networksegment as theexternal IP
addressof the BTS. It needsto be set accordingto the network
plan.
10.50.2.1
Description It is optional. -
5. After setting the parameters, click OK to finish the setting
andreturn to the ZXSDR B8200 W100 rack view.
END OF STEPS
Configuring the XBP Parameters
Prerequisites You must have logged in to the OMC and have the
configurationrights.
The B8200 rack must be created, and the XBP board must
beconfigured.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. In the left pane of the Configuration Management view,
ex-pand the configuration tree, and then select the BBU Racknode
under the Physical Configuration node of the B8200.
3. In the BBU rack view, right-click the XBP board and
chooseConfigure XBP Parameters to display the Configure
XBPParameters dialog box, as shown in Figure 26.
22 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
FIGURE 26 CONFIGURING THE XBP PARAMETERS
4. In the Port rate drop-down list, according to your
planning,set the XBP port rate to 1.25G or 2.5G.
5. Click OK to finish the setting.
END OF STEPS
Configuring the XBP R6 External IPAddress
Prerequisites You must have logged in to the OMC and have the
configurationrights.
The B8200 rack must be created, and the XBP board must
beconfigured.
At least one static route must be created.
Context The XBP board is the R6 interface board of ZXSDR B8200
W100.Hence, the external IP address of the XBP board is the R6
IPaddress through which ZXSDR B8200 W100 communicates withAGW.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. In the left pane of the Configuration Management view,
ex-pand the configuration tree, and then select the BBU Racknode
under the Physical Configuration node of the B8200.
3. In the BBU rack view, right-click the XBP board and
chooseConfigure R6 IP to display the Configure R6 External IPdialog
box, as shown in Figure 27.
Confidential and Proprietary Information of ZTE CORPORATION
23
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
FIGURE 27 CONFIGURING THE R6 IP
4. According to the network plan, set the external IP
address,MAC address, IP mask, and next hop, as shown in Table
5.
TABLE 5 R6 INTERFACE IP PARAMETERS
Parameter Description Example
External IP It is the IP addressof the R6 interfacethrough
whichZXSDR B8200 W100communicates withthe AGW. It needsto be
configuredaccording to thenetwork plan.
10.50.1.9
MAC address If there are multipleXBP boards, the MACaddresses
must beunique.
00D0D0A06E-09
IP mask It needs to be setaccording to thenetwork plan.
255.255.0.0
Next hop It must be in thesame networksegment as the R6IP
address. It needsto be set accordingto the network plan.
10.50.1.1
5. After setting the parameters, click OK to finish the setting
andreturn to the ZXSDR B8200 W100 rack view.
END OF STEPS
24 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
Configuring the (Fiber) Connectionbetween BBU and RRU
Prerequisites You must have logged in to the OMC and have the
configurationrights.
The B8200 rack must be created, and the XBP board must
beconfigured.
At least one RRU rack must be configured.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. Expand the configuration tree in the left pane of the
configura-tion management view, select the BBU Rack node under
thePhysical Configuration node of the B8200.
3. Right-click the XBP board and choose Configure
Connectionbetween BBU and RRU to display the Configure Port
Linkdialog box, as shown in Figure 28.
FIGURE 28 CONFIGURING THE PORT LINK
4. Select a port and click Modify (or double-click the port;
orright-click the port and choose Set Port Link) to display theSet
Port Link dialog box, as shown in Figure 29.
Confidential and Proprietary Information of ZTE CORPORATION
25
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
FIGURE 29 MODIFYING THE PORT LINK CONFIGURATION
5. According to your planning, select the RRU ID from RRU
sub-system number drop-down list and its port which will be
con-nected to the XBP board from the RRU port drop-down list,then
click OK to finish the settings and return to the rack view.
END OF STEPS
Result The port on which the connection is configured is changed
to green,as shown in Figure 30.
FIGURE 30 RACK VIEW WITH CONNECTION BETWEEN BBU AND
RRUCONFIGURED
26 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
Radio Configuration
Radio Configuration Flow
Figure 31 shows the radio configuration flow of ZXSDR
B8200W100.
FIGURE 31 RADIO CONFIGURATION FLOW
Configuring the QoS Priority for theR6 Port
Prerequisites You must have logged in to the OMC and have the
configurationrights.
The B8200 NE must be created.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. Select Radio Configuration node and click in the
RadioParameter window to save the current parameter as a defaultof
Global Parameter so that other tabs will change status toedit
enabled.
3. Signal Priority Configuration.
Select R6 Signal Priority tab as shown in Figure 32.
Confidential and Proprietary Information of ZTE CORPORATION
27
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
FIGURE 32 R6 SIGNAL PRIORITY
Set priority mode to Disable, ToS, DSCP from the drop-downlist;
Set Signal VLAN tag mode to Disable or Enable.
Note:
It is recommended that use the default value if you decideto
change to ToS, DSCP or VLAN tag Enable mode.
4. Media Priority Configuration.
Select R6 Media Priority tab as shown in Figure 33.
28 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
FIGURE 33 R6 MEDIA PRIORITY
Set priority mode to Disable, ToS, DSCP from the drop-downlist;
Set Signal VLAN tag mode to Disable or Enable. A param-eter list
will display in the tab when you decide to change thepriority mode
to enable, for example, DSCP. Press to savethe mode then you can
double-click a parameter value to de-fine your own customized
configuration as shown in Figure 34.
FIGURE 34 DSCP PARAMETER
END OF STEPS
Confidential and Proprietary Information of ZTE CORPORATION
29
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
Configuring a Cell
Prerequisites You must have logged in to the OMC and have the
configurationrights.
The BBU and RRU physical configuration must be completed.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. In the Configuration Management view, expand the
config-uration tree and choose the Radio Configuration node of
theB8200.
3. Right-click the Radio Configuration node and choose AddCell,
the Cell window is displayed in the right pane, as shownin Figure
35
FIGURE 35 ADDING A CELL
4. In the Cell window, select a cell number (0 ~ 5) and set
thecell alias, or click to accept the default settings. Then,
click
to save the settings.
END OF STEPS
Result A new Cell node will create under the Radio Configuration
nodeon the configuration tree.
30 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
Configuring a Carrier
Prerequisites You must have logged in to the OMC and have the
configurationrights.
The BBU and RRU physical configuration must be completed.
At least one cell must be configured.
The downlink frequency must be configured.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. In the Configuration Management view, expand the
config-uration tree in the left pane, and then choose the Cell
nodeunder the Radio Configuration node of the B8200.
3. Right-click the cell node and choose Add Carrier,and the
Car-rier window is displayed in the right pane, as shown in
Figure36.
FIGURE 36 ADDING A CARRIER
Note:
If the downlink frequency is not configured before adding
acarrier, a prompt message is displayed and the configurationdialog
box is displayed.
4. In the Carrier window, set the parameters, or click to
acceptthe default settings. Then, click to save the settings.
Confidential and Proprietary Information of ZTE CORPORATION
31
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
Note:
If not necessary, it is recommended that use the default
valuefor the parameters except carrier id and frequency
assignmentindex.
END OF STEPS
Result A new Carrier node will create under the Cell node on the
config-uration tree.
Configuring a Segment
Prerequisites You must have logged in to the OMC and have the
configurationrights.
The BBU and RRU physical configuration must be completed.
At least one cell and carrier must be configured.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. In the configuration management view, expand the
configura-tion tree in the left pane, and then choose the Carrier
node un-der the Radio Configuration node of the B8200.
Right-clickthe carrier node and choose Add Segment, and the
Segmentwindow is displayed in the right pane, as shown in Figure
37.
FIGURE 37 SEGMENT
32 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
3. Configure Segment tab.
In Segment tab, set Operator ID, BS ID, BS Alias. If thereare
more than one segments under a carrier, Preamble index,DL PUSC used
subchannel bitmap parameters setting arealso required. Click to
save settings.
Note:
You should finish the basic configuration in segment taband
click to save it or you will not able to configure inother tabs
because of losing basic parameters.
Preamble index and DL PUSC used subchannel bitmapof different
segments under one carrier can not be thesame.
There is a restriction between Preamble index and Seg-ment ID
For 1024 FFT, the restriction show like followingFigure 38. It is
recommended that use the default value ofsystem for different
segment.
FIGURE 38 RESTRICTION BETWEEN PREAMBLE INDEX AND SEGMENTID
DL PUSC used subchannel bitmap indicate the subchan-nel group
which is used by a segment. A new segment willuse all the
subchannel bitmaps as default. But in multi-seg-ment situation, 3
segments for example, assign subchannelbitmap to each segment is
necessary. It is recommendedthat segment 0 use (bit0) Group #0 and
(bit1) Group#1; segment 1 use (bit2) Group #2 and (bit3) Group#3;
segment 2 use (bit4) Group #4 and (bit5) Group#5.
4. Apply AGW.
Confidential and Proprietary Information of ZTE CORPORATION
33
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
In AGW tab, click button or right-click a null data recordand
select Add, Add AGW dialog box will display as shown inFigure
39.
FIGURE 39 ADD AGW
Select a AGW record and click OK to apply it to segment. Youcan
apply more than one AGW to one segment using settingdifferent
priority from the drop-down list.
Note:
In radio configuration, when a global AGW under a segmentis
added, deleted or modified, the AGW record takes effectfor the
other segment under the same BTS. This ensuresthat the AGW records
of each segment are the same.
For a segment, up to 4 AGW records can be added.
5. Configure Idle.
In Idle tab, click button or right-click a null data recordand
select Add, Add Paging Group dialog box will display asshown in
Figure 40.
34 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
FIGURE 40 ADD PAGING GROUP
You can choose one or more paging groups, click OK to apply.
END OF STEPS
Result A new Segment node will create under the Carrier node on
theconfiguration tree.
Managing the BTS StatusPrerequisites You must have logged in to
the OMC and have the configuration
rights.
The District node must exist.
The BTS node must exist.
Context Through this operation, you can query and modify the
commis-sioning status and cutover status easily.
A new BTS is in the configuring status by default. In this
case,the IP link cannot be set up between the OMC and BTS, and
thedata synchronization operation is not allowed. The IP link canbe
set up (after BTS external IP address is configured) and
datasynchronization and saving can be performed only after the
BTScommissioning status is set to integrated or commercial. The
traf-fic volume of new BTSs is usually not large, but the traffic
volumeof cutover BTSs is usually very large, so the two statuses
need tobe distinguished. In this way, the maintenance personnel can
payattention to the two types of BTSs differently.
Steps 1. Choose Views > Configuration Management to display
theConfiguration Management view.
2. In the Configuration Management view, expand the
config-uration tree to the District node, and the System
Configu-ration window is displayed in the right pane.
3. Click the NE Status tab, as shown in Figure 41.
Confidential and Proprietary Information of ZTE CORPORATION
35
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
FIGURE 41 NE STATUS
4. On the NE Status tab, right-click an NE record and
chooseModify NE Status to display the Modify NE Status dialogbox,
as shown in Figure 42.
FIGURE 42 MODIFY NE STATUS
36 Confidential and Proprietary Information of ZTE
CORPORATION
-
Chapter 2 Basic Data Configuration
5. Set Administrative status to Configuring, Integrated
orCommercial. Set Cutover status to New site or Swappingsite. Enter
remarks in the Note area.
END OF STEPS
Result If you set the NE status to commercial, the status is
changed fromN to CS, as shown in Figure 43.
FIGURE 43 B8200 NODE COMMISSIONING STATUS MARK
Synchronizing DataPrerequisites You must have logged in to the
OMC and have the configuration
rights.
The data configuration must be complete and correct.
The BTS status must be integrated or commercial.
Steps 1. Select Views > Configuration Management to display
theConfiguration Management view.
2. In the Configuration Management view, right-click
theOMM_WiMAX node on the configuration tree, and thenchoose
Synchronize Data to display the Data Synchroniza-tion window, as
shown in Figure 44.
Confidential and Proprietary Information of ZTE CORPORATION
37
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
FIGURE 44 DATA SYNCHRONIZATION
3. In the NE tree in the left pane, select the required NEs,
andthen click on the toolbar. In the confirmation dialog boxthat
appears, click OK to start data synchronization. Duringthe
synchronization process, the synchronization progress isdisplayed
in the Synchronization progress bar.
END OF STEPS
Result After the data synchronization is completed, the
synchronizationresult is displayed as shown in Figure 45.
FIGURE 45 SYNCHRONIZATION RESULT
38 Confidential and Proprietary Information of ZTE
CORPORATION
-
Figures
Figure 1 Typical Configuration
.............................................. 1
Figure 2 Position in the WiMAX
Network................................. 2
Figure 3 Networking of ZXSDR B8200 W100 and AGW.............
3
Figure 4 Networking of ZXSDR B8200 W100 and RRU..............
4
Figure 5 Physical Configuration
Flow...................................... 6
Figure 6 Configuration Management View
.............................. 7
Figure 7 Global Parameter Configuration
................................ 7
Figure 8 Add AGW
..............................................................
8
Figure 9 Add Downlink Frequency
......................................... 9
Figure 10 Add Foreign BS
...................................................10
Figure 11 Add Paging
Group................................................10
Figure 12 Add
OMC-IP........................................................11
Figure 13 Add District
........................................................12
Figure 14 Adding a BTS
......................................................12
Figure 15 Physical Configuration
..........................................13
Figure 16 CPU Overload Threshold
Configuration....................14
Figure 17 Add Static Route
.................................................14
Figure 18 OMC
VLAN..........................................................15
Figure 19 Adding a BBU Rack
..............................................16
Figure 20 Adding a Board
...................................................17
Figure 21 Adding Board Complete
........................................17
Figure 22 Configure Work
Mode...........................................18
Figure 23 Configure Work
Mode...........................................19
Figure 24 Configure Receivable Mode
...................................20
Figure 25 Configuring the BTS External
IP.............................21
Figure 26 Configuring the XBP Parameters
............................23
Figure 27 Configuring the R6
IP...........................................24
Figure 28 Configuring the Port Link
......................................25
Figure 29 Modifying the Port Link Configuration
.....................26
Figure 30 Rack View with Connection between BBU and RRU
Configured........................................................26
Figure 31 Radio Configuration Flow
......................................27
Figure 32 R6 Signal
Priority.................................................28
Figure 33 R6 Media Priority
.................................................29
Confidential and Proprietary Information of ZTE CORPORATION
39
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
Figure 34 DSCP
Parameter..................................................29
Figure 35 Adding a Cell
......................................................30
Figure 36 Adding a Carrier
..................................................31
Figure 37 Segment
............................................................32
Figure 38 Restriction Between Preamble index and Segment
ID
...................................................................33
Figure 39 Add AGW
...........................................................34
Figure 40 Add Paging
Group................................................35
Figure 41 NE
Status...........................................................36
Figure 42 Modify NE
Status.................................................36
Figure 43 B8200 Node Commissioning Status Mark
................37
Figure 44 Data Synchronization
...........................................38
Figure 45 synchronization Result
.........................................38
40 Confidential and Proprietary Information of ZTE
CORPORATION
-
Tables
Table 1 NE Meaning Description
............................................ 2
Table 2 Module Meanings Description
.................................... 3
Table 3 Static Route Configuration Description
.......................15
Table 4 BTS External IP Address
Description..........................21
Table 5 R6 Interface IP Parameters
......................................24
Confidential and Proprietary Information of ZTE CORPORATION
41
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
This page is intentionally blank.
42 Confidential and Proprietary Information of ZTE
CORPORATION
-
Index
AAGW Adapting...................33AGW Configuration
..............8
BBTS IP Configuration..........21
CCarrier Configuration..........31Cell Configuration
..............30CPU Overload
ThresholdConfiguration...................13
DDownlink FrequencyConfiguration.....................8
FForeign BS Configuration ......9
IIdle Configuration..............34
NNE Status .........................35
OOMC IP Configuration.........11OMC VLAN
Configuration.....15
PPaging GroupConfiguration...................10Physical
ParameterConfiguration...................13Port
Connection.................25
RR6 IP Configuration............23Receivable
Mode................20
SSegment Configuration.......33Static Route Configura-tion
................................14Synchronization
................37
Confidential and Proprietary Information of ZTE CORPORATION
43
-
ZXSDR B8200 W100 Commissioning and Data Configuration Manual
This page is intentionally blank.
44 Confidential and Proprietary Information of ZTE
CORPORATION
-
Glossary
AGW- ASN Gateway
ASN- Access Service Network
BS- Base Station
BTS- Base Transceiver Station
CC- Control and Clock Module
FA- Fan Array Module
PM- Power Module
RRU- Remote Radio Unit
SA- Site Alarm Module
XBP- X Baseband Processing Module
Confidential and Proprietary Information of ZTE CORPORATION
45
About This ManualDeclaration of RoHS ComplianceOverviewTypical
ConfigurationPosition in the NetworkConnection Mode between ZXSDR
B8200 W100 and AGWConnection Mode between ZXSDR B8200 W100 and
RRU
Basic Data ConfigurationPhysical ConfigurationPhysical
Configuration FlowConfiguring Global ParametersAdding a
B8200Configuring the BBU Basic InformationAdding a BBU RackAdding
BoardsConfiguring the CC Work ModeConfiguring the XBP Work
ModeConfiguring the Receivable Mode on CCConfiguring the BTS
External IPConfiguring the XBP ParametersConfiguring the XBP R6
External IP AddressConfiguring the (Fiber) Connection between BBU
and RRU
Radio ConfigurationRadio Configuration FlowConfiguring the QoS
Priority for the R6 PortConfiguring a CellConfiguring a
CarrierConfiguring a Segment
Managing the BTS StatusSynchronizing Data
FiguresTablesIndexGlossary