UNIVERSITI PUTRA MALAYSIA MODIFICATION OF SCREEN PRINTED CARBON ELECTRODE WITH SILICON NANOWIRES FOR ELECTROCHEMICAL DETECTION OF Hg(II) AND Cd(II) IN WATER SITI NUR ZAWANI BINTI MOHAMAD ZAIN FS 2015 61
UNIVERSITI PUTRA MALAYSIA
MODIFICATION OF SCREEN PRINTED CARBON ELECTRODE WITH SILICON NANOWIRES FOR ELECTROCHEMICAL DETECTION OF Hg(II)
AND Cd(II) IN WATER
SITI NUR ZAWANI BINTI MOHAMAD ZAIN
FS 2015 61
© COPYRIG
HT UPM
MODIFICATION OF SCREEN PRINTED CARBON ELECTRODE WITH
SILICON NANOWIRES FOR ELECTROCHEMICAL DETECTION OF Hg(II)
AND Cd(II) IN WATER
By
SITI NUR ZAWANI BINTI MOHAMAD ZAIN
Thesis Submitted to the School of Graduate Studies, Universiti
Putra Malaysia, in Fulfilment of the Requirements for the Master of
Science
May 2015
© COPYRIG
HT UPM
All material contained within the thesis, including without limitation text, logos, icons,
photographs and all other artwork, is copyright material of Universiti Putra Malaysia
unless otherwise stated. Use may be made of any material contained within the thesis
for non-commercial purposes from the copyright holder. Commercial use of material
may only be made with the express, prior, written permission of Universiti Putra
Malaysia.
Copyright © Universiti Putra Malaysia
© COPYRIG
HT UPM
i
Abstract of thesis presented to the Senate of Universiti Putra Malaysia in fulfilment of
the requirement for the degree of Master of Science
MODIFICATION OF SCREEN PRINTED CARBON ELECTRODE WITH
SILICON NANOWIRES FOR ELECTROCHEMICAL DETECTION OF Hg(II)
AND Cd(II) IN WATER
By
SITI NUR ZAWANI MOHAMAD ZAIN
May 2015
Chairman: Ruzniza Mohd Zawawi, PhD
Faculty: Science
Water pollution resulting from heavy metal ions such as mercury and cadmium tends to
have lethal effects on the environment and living organisms. This indicates the need for
further research to develop on heavy metal sensors that are fast, potable and cost
effective. In this research, Silicon Nanowires (SiNW’s), a 1-dimensional nanowire was
used as a modifier for disposable screen printed carbon electrodes (SPCE) for detection
of metal ions. The SiNW’s was characterized by different spectroscopic techniques and
the application of SiNW’s on the surface of the electrode was found to increase the
sensitivity of the electrode.
The screen printed carbon electrode was modified by casting SiNW’s with 3-
aminopropyl-triethoxysilane (APTES) onto the working electrode surface. The
modified electrode (SiNW’s/APTES/SPCE) was then applied for Hg2+ and Cd2+ ion
detection. Electrochemical studies using linear sweep stripping voltammetry performed
with SiNW’s/APTES/SPCE were found to give a better response through the
optimization of some analytical parameters.
Concentration study of mercury with SiNW’s/SPCE gave linear calibrations and a
detection limit value of 42.59 μg L−1 was achieved by applying deposition potential of
-1.2V and deposition time of 160s. The electrode showed very good recovery
indicating the accuracy of the method, while concentration study of cadmium with
SiNW’s/SPCE gave a linear calibration with R2 = 0.994. A detection limit of 251.7
μg L−1 was also achieved by applying deposition potential of -1.2V and deposition time
of 160s. Validation of the method with inductively coupled plasma-mass spectroscopy
(ICP-MS) and atomic absorption spectroscopy showed very good correlation. This
modified screen printed carbon electrodes with Silicon Nanowires
(SiNW’s/APTES/SPCE) also found for simultaneously detection of Hg2+ and Cd2+ ions
in the solution.
© COPYRIG
HT UPM
ii
Abstrak tesis yang dikemukakan kepada Senat Universiti Putra Malaysia sebagai
memenuhi keperluan untk ijazah Sarjana Sains
PENGUBAHSUAIAN ELEKTROD KARBON SKRIN TERCETAK DENGAN
SILICON NANOWIRES(SiNW’S) UNTUK PENGESANAN ELEKTROKIMIA
BAGI Hg(II) DAN Cd(II) DI DALAM AIR
Oleh
SITI NUR ZAWANI MOHAMAD ZAIN
Mei 2015
Pengerusi: Ruzniza Mohd Zawawi, PhD
Fakulti: Sains
Pencemaran air dengan ion logam berat seperti merkuri dan kadmium memberi kesan
kepada persekitaran dan organisma hidup. Ini menunjukkan penyelidikan mengenai
penderia logam berat yang memberi keputusan yang pantas, ringkas dan kos efektif
adalah diperlukan. Dalam kajian ini, Silicon Nanowires(SiNW’s) yang merupakan 1-
dimensi dawai nano telah digunakan sebagai bahan pengubah suai untuk elektrod
karbon skrin tercetak terpakai buang untuk mengesan logam berat ion. SiNW’s telah di
cirikan dengan menggunakan teknik spektroskopi, dan SiNW’s diaplikasikan ke atas
permukaan elektrod untuk meningkatkan kepekaan electrod tersebut.
Elektrod karbon skrin tercetak telah diubah suai dengan melekatkan SiNW’s dengan
APTES diatas permukaan elektrod kerja. Elektrod yang diubah suai
(SiNW’s/APTES/SPCE) telah diaplikasikan untuk mengesan Hg2+ dan Cd2+ ion. Kajian
elektrokimia menggunakan voltametri sapuan linear pelucutan dilakukan menggunakan
SiNW’s/APTES/SPCE memberi kesan yang lebih baik dengan mengoptimumkan
sebahagian parameter analisis.
Kajian kepekatan merkuri dengan SiNW’s/APTES/SPCE telah memberikan
penentukuran linear dan had pengesanan 42.59 μg L−1 dengan menggunakkan potensi
pemendapan -1.2V dan masa pemendapan selama 160s. Elektrod ini menunjukkan
pengambilan semula yang baik yang menunjukkan ketepatan kaedah ini. Sementara
kajian kepekatan kadmium dengan SiNW’s/APTES/SPCE telah memberikan
penentukuran linear dengan R2 = 0.994. Had pengesanan 251.7 μg L−1 telah dicapai
dengan menggunakan potensi pemendapan -1.2V dan masa pemendapan selama 160s.
Pengesahan kaedah ini dengan Spektrometriberat–induktif pasangan plasma (ICP-MS)
dan spektroskopi serapan atom menunjukan korelasi yang sangat baik. Dengan elektrod
karbon skrin tercetak dengan SiNW’s (SiNW’s/APTES/SPCE) ini juga didapati
mampu untuk mengesan Hg2+ dan Cd2+ secara serentak.
© COPYRIG
HT UPM
iii
ACKNOWLEDGEMENTS
Firstly, I would like to thanks to my supervisor and co-supervisor Dr. Ruzniza Mohd
Zawawi and Prof Nor Azah Yusof for their encouragement and help. Without their
help, guidance encouragement and knowledge I can’t reach this state.
To my beloved parents, mama and ayah thank you so much support my journey to
continue my study. Without them I can’t achieved my dream. To my siblings thank you
for financial support and advice. To my husband thank you so much for your fully
support to me to finish this study.
To my friends and colleagues, izzah, k.emy, iffah, wani thank you for support and
make me enjoying life at UPM. The enjoying time in UPM will be in my memory
forever. Their encouragement to me to finish my study, love all of you. Special thanks
farhana, zida, zira, salama always advise me and make me motivated to finish my
journey in this study.
Best Regards
© COPYRIG
HT UPM
iv
I certify that a Thesis Examination Committee has met on 11th May 2015 to conduct
the final examination of Siti Nur Zawani Mohamad Zain on her thesis entitled
Modification Of Screen Printed Carbon Electrode With Silicon Nanowires (SiNW’s)
For Electrochemical Detection Of Hg(II) And Cd(II) In Water in accordance with the
Universities and University Colleges Act 1971 and the Constitution of the Universiti
Putra Malaysia [P.U.(A) 106] 15 March 1998. The Committee recommends that the
student be awarded the Master of Science.
Members of the Thesis Examination Committee were as follows:
Haslina Binti Ahmad, PhD
Faculty of Science
Universiti Putra Malaysia
(Chairman)
Zulkarnain B Zainal, PhD
Faculty of Science
Universiti Putra Malaysia
(Internal Examiner)
Yatimah Alias, PhD
Department of Chemistry
Faculty of Science
Universiti Malaya
(External Examiner)
____________________________________
ZULKARNIAN ZAINAL, PhD
Deputy Dean
School of Graduate Studies
Universiti Putra Malaysia
Date: 12 August 2015
© COPYRIG
HT UPM
v
This thesis was submitted to the Senate of Universiti Putra Malaysia and has been
accepted as fulfilment of the requirement for the degree of Master of Science. The
members of the Supervisory Committee were as follows:
Ruzniza Mohd Zawawi, PhD
Senior Lecturer
Faculty of Science
Universiti Putra Malaysia
(Chairman)
Nor Azah Yusof, PhD
Professor
Faculty of Science
Universiti Putra Malaysia
(Member)
_________________________________
BUJANG BIN KIM HUAT, PhD
Professor and Dean
School of Graduate Studies
Universiti Putra Malaysia
Date:
© COPYRIG
HT UPM
vi
Declaration by graduate student
I hereby confirm that:
this thesis is my original work;
quotations, illustrations and citations have been duly referenced;
this thesis has not been submitted previously or concurrently for any other degree
at any other institutions;
intellectual property from the thesis and copyright of thesis are fully-owned by
Universiti Putra Malaysia, as according to the Universiti Putra Malaysia
(Research) Rules 2012;
written permission must be obtained from supervisor and the office of Deputy
Vice-Chancellor (Research and Innovation) before thesis is published (in the form
of written, printed or in electronic form) including books, journals, modules,
proceedings, popular writings, seminar papers, manuscripts, posters, reports,
lecture notes, learning modules or any other materials as stated in theUniversiti
Putra Malaysia (Research) Rules 2012;
there is no plagiarism or data falsification/fabrication in the thesis, and scholarly
integrity is upheld as according to the Universiti Putra Malaysia (Graduate
Studies) Rules 2003 (Revision 2012-2013) and the Universiti Putra Malaysia
(Research) Rules 2012. The thesis has undergone plagiarism detection software.
Signature: ________________________ Date: __________________
Name and Matric No.: _________________________________________
© COPYRIG
HT UPM
vii
Declaration by Members of Supervisory Committee
This is to confirm that:
the research conducted and the writing of this thesis was under our supervision;
supervision responsibilities as stated in the Universiti Putra Malaysia (Graduate
Studies) Rules 2003 (Revision 2012-2013) are adhered to.
Signature: _______________________
Name of
Chairman of
Supervisory
Committee: _______________________
Signature: _______________________
Name of
Member of
Supervisory
Committee: _______________________
Signature: _______________________
Name of
Member of
Supervisory
Committee: _______________________
© COPYRIG
HT UPM
viii
TABLE OF CONTENTS
Page
ABSTRACT i
ABSTRAK ii
ACKNOWLEDGEMENT iii
APPROVAL iv
DECLARATION vi
LIST OF FIGURES x
LIST OF TABLES xiii
LIST OF ABBREVIATIONS xiv
CHAPTER
1 INTRODUCTION 1.1 Heavy Metals 1 1.2 Screen Printed Electrode (SPEs) 3
1.3 Problem Statement 3
1.4 Objective of the studies 4
1.4.1 General Objective 4
1.4.2 Specific Objective 4
2 LITERATURE REVIEWS 5 2.1 Cadmium toxicity 5
2.2 Mercury toxicity 5
2.3 Voltammetry 5
2.4 Linear sweep voltammetry (LSV) 7
2.5 Anodic stripping voltammetry (ASV) 8
2.6 Preparation of sensors 10
2.6.1 Modification of Screen printed electrode by nanomaterial 10
2.6.2 Silicon Nanowires 11
2.6.3 Ionophore 12
2.6.4 Application of Ionophore in Development of Heavy Metal
Detection 13
3 METHODOLOGY 15 3.1 Material and reagents 15
3.1.1 Transmission Electron Microscopy (TEM) 14
3.1.2 Inductively Coupled Plasma (ICP) 16
3.1.3 Atomic Absorption Spectroscopy (AAS) 16
3.2 Preparation of modified electrodes (Screen printed carbon electrode) 17
3.3 Preparation of working electrode 17
3.4 General procedures for electrochemical measurements 17
3.5 General procedures for sample measurements 18
3.5.1 Transmission Electron Microscopy (TEM) 18
3.5.2 Inductively Coupled Plasma (ICP) 18
3.5.3 Atomic Absorption Spectroscopy (AAS) 18
3.6 Optimization of the Screen Printed Carbon Electrode 19
3.6.1 Effect of supporting Electrolyte 19
3.6.2 Effect of Deposition Potential 19
© COPYRIG
HT UPM
ix
3.6.3 Effect of Deposition Time 19
3.6.4 Effect of Varying Scan Rate 19
3.6.5 Effect of Varying Hg2+ and Cd2+ Concentration 19
3.6.6 Effect of foreign Substances 20
3.6.7 Analysis of Cd2+ and Hg2+ in Waste Water 20
3.6.8 Reproducibility 20
4 RESULT AND DISCUSSION 21 4.1 Morphology of electrode 21
4.2 Effect of supporting Electrolyte for detection of Hg2+ and Cd2+ ions 23
4.3 Effect of Deposition Time for Hg2+ and Cd2+ ions detection 27
4.4 Effect of Deposition Time for Hg2+ and Cd2+ ions detection 28
4.5 Effect of Varying Scan Rate for Hg2+ and Cd2+ ions detection 29
4.6 Effect of Varying Hg2+ and Cd2+ Concentration 33
4.7 Electrochemical Characterization of the Modified Screen
Printed Electrode for detection of Hg2+ and Cd2+ 36
4.8 Effect of Foreign Substances for Hg2+ and Cd2+ ions detection 38
4.9 Analysis of Hg2+ and Cd2+ in SeaWater 40
4.10 Reproducibility and Stability for Hg2+ and Cd2+ ions 40
4.11 Modification SiNW’S/APTES/Mercury ionophore /SPCE 41
4.11.1 Effect of ionophore/SiNW’s in stripping current of Hg2+ 41
4.11.2 Comparison study 42
4.11.3 Effect of various Hg2+ concentrations 43
5 CONCLUSION AND RECOMMENDATIONS FOR FUTURE
RESEARCH 45
REFERENCES 47
APPENDICES 53
BIODATA OF STUDENT 55
LIST OF PUBLICATION 56
© COPYRIG
HT UPM
x
LIST OF FIGURES
Figure Page
1.1 Source of Heavy Metal Pollution to Aqueous System
(http://www.sagasiki-kankyo.co.jp)
1
1.2 Schematic diagram of bio/chemical sensor 2
1.3 Screen printed carbon electrode consists of working electrode;
counter electrode and reference electrod
3
2.1 Schematic diagram of Linear Sweep Voltammetry (LSV) (A)
voltage scanned from a lower limit to an upper limit by
changing the time & (B) current response plotted as a function
of voltage
7
2.2 Series of linear sweep voltammograms recorded at different
scan rates
8
2.3 Schematic diagram of Anodic Stripping Voltammetry (ASV)
process with Cd2+ analytes at the SPE
9
2.4 Schematic diagram of the ASV process with 4 steps (A)
Cleaning step, (B) Electroplating step, (C) Equilibration step
and (D) Stripping step
9
3.1 Schematic diagram of modern analytical electron microscope 15
3.2 Schematic diagram of experimental setup used in this study 18
4.1 FESEM images of unmodified SPCE and SiNW’s modified
SPCE: (a) unmodified SPCE; (b) SiNW’s/APTES modified
SPCE.
21
4.2 The fabrication process for modification of SiNW’s
/APTES/SPCE.
22
4.3 FESEM-EDS analysis result for a) unmodified SPCE and b)
modified SPCE with SiNWs/APTES
22
4.4 TEM image of the functionalize of SiNW’s with APTES 23
4.5 LSASV voltammograms for SiNW’s/APTES/SPCE in 100
ppm Hg2+ with (a) 0.1 M Na2SO4, (b) 0.1 M Acetic Buffer (c)
0.1 M KCl and (d) 0.1 M HCl electrolyte. Potential scanning
in positive direction from -1.0 V to -0.3 V vs Ag/AgCl at scan
rate of 100 mVs-1 , deposition potential;-1.2, deposition time:
120 secs.
24
4.6 LSASV voltammograms for SiNW’s/APTES/SPCE in 100
ppm Cd2+ with (a) 0.1 M Na2SO4, (b) 0.1 M Acetic Buffer (c)
0.1 M KCl and (d) 0.1 M HCl electrolyte. Potential scanning
in positive direction from -1.0 V to -0.3 V vs Ag/AgCl at scan
rate of 100 mVs-1, deposition potential: -1.2V, deposition
time; 120 secs.
25
4.7 Effect of the HCl concentration on the peak current of Hg2+
and Cd2+ in the solution of 100 ppm Cd2+ and 100 ppm Hg2+,
Deposition time: 120 secs; Deposition potential -1.2 V.
26
4.8 Effect of deposition potential on the peak current of Hg2+ and
Cd2+ in the solution of 100 ppm Cd2+ and 100 ppm Hg2+.
27
4.9 Effect of deposition time on the peak current of Hg2+ and Cd2+
in the solution of 10 ppm Cd2+ and 5 ppm Hg2+: Deposition
potential -1.2.
28
4.10 Effect of varying the scan rate on the LSV of 29
© COPYRIG
HT UPM
xi
SiNW’s/APTES/SPCE in 100 ppm Hg2+ and 0.05 M HCl as
supporting electrolyte. Potential scanning in positive direction
from -0.2 V to 0.5 V vs Ag/AgCl at a scan rate 0.01 Vs-1 to
0.1 Vs-1, deposition potential: -1.2, deposition time: 160 secs.
4.11 (A) Dependence of log cathodic current on log (V) (B) current
vs V and (C) current vs V1/2 for SiNW’s/APTES/SPCE in 10
ppm Hg2+ and 0.05 M HCl as supporting electrolyte. Potential
scanning in positive direction from -0.2 V to 0.5 V vs
Ag/AgCl at scan rate 0.01 Vs-1 to 0.1 Vs-1, deposition
potential:-1.2, deposition time: 160 secs.
31
4.12 Effect of varying the scan rate on the LSV of
SiNW’s/APTES/SPCE in 10 ppm Cd2+ and 0.05 M HCl as
supporting electrolyte. Potential scanning in positive direction
from -1.1 V to -0.3 V vs Ag/AgCl at scan rate of 0.01 Vs-1 to
0.1 Vs-1, deposition potential: -1.2, deposition time: 160 secs.
31
4.13 (A) Dependence of log cathodic current on log scan rate (B)
current vs V and current vs V1/2 for SiNW’s/APTES/SPCE in
10 ppm Cd2+ and 0.05 M HCl as supporting electrolyte.
Potential scanning in positive direction from -0.2 V to 0.5 V
vs Ag/AgCl at scan rate of 0.01 Vs-1 to 0.1 Vs-1, deposition
potential: -1.2, deposition time: 160 secs.
33
4.14 Votammograms of SiNW’s/APTES/SPCE in 0.05M HCl
supporting electrolyte with different concentrations of Hg2+.
Potential scanning in positive direction from -0.5 V to 0.5 V
vs Ag/AgCl at scan rate of 100 mVs-1.
34
4.15 Current intensity versus concentration of Hg2+ in range of 4 -
18 ppm using SiNW’s/APTES/SPCE in 0.05 M HCl as
supporting electrolyte. Potential scanning in positive direction
from -0.5 V to 0.5 V vs Ag/AgCl at scan rate of 100 mVs-1.
34
4.16 Votammograms of SiNW’s/APTES/SPCE in 0.05M HCl
supporting electrolyte with different concentrations of Cd2+.
Potential scanning in positive direction from -1.0 V to -0.6 V
vs Ag/AgCl at scan rate of 100 mVs-1.
35
4.17 Current intensity versus concentration of Hg2+ in range of 4 –
18 ppm using SiNW’s/APTES/SPCE in 0.05 M HCl as
supporting electrolyte. Potential scanning in positive direction
from -1.0 V to -0.6 V vs Ag/AgCl at scan rate of 100 mVs-1.
35
4.18 Voltammogram of simultaneous detection at constant
concentration of 10 ppm of Cd2+ and various concentrations of
Hg2+ ions.
36
4.19 Comparison of LSASV voltammograms for (a) unmodified
SPCE and (b) modified SiNW's/APTES/SPCE in 10 mg/L
Hg2+ and 0.05M HCl, deposition potential: -1.2, deposition
time:160 secs, potential scanning in positive direction from -
0.4 V to 0.4 V vs Ag/AgCl at scan rate of 100 mVs-1
37
4.20 Comparison of LSASV voltammograms for (a) unmodified
SPCE and (b) modified SiNW's/APTES/SPCE in 10 mg/L
Cd2+ and 0.05M HCl, deposition potential:-1.2, deposition
time;160 secs, potential scanning in positive direction from -
1.1 V to -0.3 V vs Ag/AgCl at scan rate of 100 mVs-1
37
4.21 Effect of foreign substances in Hg2+ using 39
© COPYRIG
HT UPM
xii
SiNW’s/APTES/SPCE in 0.05M HCl as supporting
electrolyte.
4.22 Effect of foreign substances in Cd2+ using
SiNW’s/APTES/SPCE in 0.05M HCl as supporting
electrolyte.
39
4.23 Stability Study for 10 ppm Hg2+ with SiNW’s/APTES/SPCE 41
4.24 Effect of Mercury ionophore concentration versus current 42
4.25 Voltammogram for mixture of 10ppm of Cd2+Pb2+and Hg2+in
0.05M HCl using SiNW’s/APTES/SPCE and
SiNW's/APTES/Hg ionophore/SPCE
42
4.26 Hg ionophore and the interaction of Hg ionphore with Hg2+
ions
43
4.27 Votammograms of SiNW’s/APTES/Hg ionophore screen
printed carbon electrode in 0.05M HCl supporting electrolyte
with different concentration of Hg2+Potential scanning in
positive direction from -0.5 V to 0.5 V vs Ag/AgCl at a scan
rate 100mVs-1.
43
4.28 Current intensity versus concentration of Hg2+ in range of
2ppm to 10ppm using SiNW’s /APTES/Hg ionophore
modified screen printed carbon electrode in 0.05 M HCl as
supporting electrolyte. Potential scanning in positive direction
from -0.5 V to 0.5 V vs Ag/AgCl at a scan rate 100mVs-1.
44
© COPYRIG
HT UPM
xiii
LIST OF TABLES
Table Page
2.1 Electrochemical Sensors applied in Hg2+ detection 6
2.2 Electrochemical Sensors applied in Cd2+ detection 7
2.3 Various examples of ionophores for determination of heavy
metal ions
14
3.1 Hg2+ and Cd2+ concentration study on modified electrode 20
4.1 Summary of detection limit for Hg2+ and Cd2+ modified
SiNW’s/APTES/SPCE under optimum condition with LSASV 33
4.2 Determination of Hg2+ and Cd2+ ions in sea water using
SiNW’s/APTES/SPCE in 0.05M HCl as supporting electrolyte.
40
4.3 Reproducibility study for 100 ppm Cd2+ and 10 ppm Hg2+ ions
with SiNW’s/APTES/SPCE
41
© COPYRIG
HT UPM
xiv
LIST OF ABBREVIATIONS
A Electrode surface area
APTES 3-aminopropyl-triethoxysilane
ASV Anodic Stripping Voltammetry
AuNP Gold nanoparticles
C Concentration of analyte or reactant in the bulk solution
CNT Carbon nanotubes
CSV cathodic stripping voltammetry
CV Cyclic Voltammetry
DPASV Differintial Pulse Anodic Stripping Voltammetry
GCE Glassy carbon electrode
I Current
LSASV Linear Sweep Anodic Stripping Voltammetry
MWCNT Multi wall carbon nanotubes
N Numbers of electrons
ppb part per billion
ppm part per million
SAM Self-assembled monolayer
SiNW’s Silicon Nanowire’s
SPCE screen printed carbon electrode
SPE screen printed electrode
SWASV Square Wave Anodic Stripping Voltammetry
v Scan rate
WHO World Health Organization
© COPYRIG
HT UPM
1
CHAPTER 1
INTRODUCTION
1.1 Heavy Metals
Heavy metals are mostly defined by their chemical properties such as malleability,
ductility with metallic luster and the ability to conduct heat and electricity as well as
possessing the ability to lose its outer most electrons to form cations with basic oxides
(John et al., 2002). They are group of metals with a high density which is greater than
5 gcm-3. Heavy metals are known to form stable complexes or chelates with a variety of
ligands and their average stability decreases with electronegativity of the metal in
which they are attached to in the following order Pd > Cu > Ni > Co > Zn > Cd > Mn
(Mellor et al., 1947, Irving et al., 1948). And several factors such as pH, are found to
influence this order.
Heavy metal ions are regarded as the most toxic pollutants due to their acute toxicities,
carcinogenicities and non-biodegradability. The main sources of heavy metal
contamination are mostly contributed from metal related industries such as metal
plating facilities, mining operations, fertilizer and electronic device manufactures,
agricultural activities, vehicle emission, and domestic activities (Juang et al., 2002).
The oxidation of the different metal species causes the solubility of the metal ions thus
released into the surrounding environment through water drainages.
Wastes discharged from industrial and agricultural activities containing heavy metal
can accumulate into sludge and drain down to cultivated soil; hence, this could easily
be transferred into the food chain (Zhao et al., 2014). In many developing countries
around the world, an increasing concentration of heavy metals in the environment is a
serious problem to both human and animal health as well as protection and production
of food stuffs.
Figure 1.1: Source of Heavy Metal Pollution to Aqueous System
(http://www.sagasiki-kankyo.co.jp)
© COPYRIG
HT UPM
2
Previous studies have proved that the use of spectroscopic techniques, such as
inductively coupled plasma mass spectrometry (Hassan et al., 2004), surface-enhanced
raman scattering (Enzhong et al., 2012) and cold vapour atomic fluorescence
spectroscopy (Yu et al., 2005) in detecting the presence of this heavy metals can yield
an accurate result. However, these techniques are highly costly because it requires
expensive instruments, routine maintenance and specialized personnel in order to run
the samples. These techniques also do not allow onsite analysis due to non-portability
of the equipment.
For these reasons electrochemical sensors were developed and extensively being used
in studying environmental pollution with diverse industrial applications. There is high
demand of sensors in the world market that are easy to handle, compatible and can give
a fast result. These sensors also offer advantages of low detection limits, a wide linear
response range, good stability and reproducibility. Electrochemical sensor can be
portable, simple to use,in-situ and miniature in size.These features are ideal for real
time on field manaagement, thus the errors caused by the sample transportation and
storage can largely be reduced (Cammann et al., 1996). The biochemical sensor usually
consists of the analyte for example food sample, environmental sample or human
sample and receptor that is specifically binded to the analyte, transducer element for
example nanomaterial converted to an electronic signal by electrodes and amplified by
a detector circuit using an appropriate reference and sent for processing to the computer
software to be converted to a meaningful physical feature for example light, signal,
and data display (Belluzo et al., 2007).
Figure 1.2: Schematic diagram of a bio/chemical sensor
The electroanalytical techniques that are usually employed in chemical sensor analysis
includes; cyclic voltammetry(CV), differential pulse voltammetry (DPV), square wave
voltammetry (SWV) and stripping voltammetry (SV). The stripping voltammetry is a
sensitive electroanalytical technique used for the determination of trace amount of
metals in a given solution. The technique consists of three steps. In the first step, metal
ions are deposited onto an electrode which is held at a suitable potential. The solution
is stirred during this step in order to maximize the amount of metal deposited. For the
second step, stirring is stopped so that the solution will settles and finally in the third
step, the metal deposits are stripped from the electrode by scanning the potential. The
observed current during the stripping step can be used as an indirect measuremnt for
the amount of metals in the solution.
© COPYRIG
HT UPM
3
The stripping step may consist of a positive or negative potential scan by creating either
an anodic or cathodic current respectively. Hence, they are named as anodic stripping
voltammetry (ASV) and cathodic stripping voltammetry (CSV). Anodic stripping
voltammetry (ASV) has been recognized as a powerful technique for electrochemical
measurements of trace metal ions in various samples of environmental, clinical, and
industrial origin (Injang et al., 2010 , Yi et al., 2012) in particular due to its capability
of preconcentrating analytes on the surface of the working electrode. It also allows
quantification of heavy metal ions down to part per million (ppm) or even to part per
billion (ppb) (Gu et al.,2013). Cyclic voltammetry (CV) is also widely used to study
the presence of heavy metal but is not sensitive enough for environmental analysis
never the less it is useful in optimization of analytical conditions (Buffle et al., 2005).
1.2 Screen Printed Electrode (SPEs)
The advent of disposable screen printed electrodes (SPEs) as an alternative to the
conventional electrodes in development of analytical methods that respond to perform
rapid ‘in situ’ analyses has become necesary due to many advantages it possess such as
low cost, ease of handling and ease of preparation and moreover can be treated as
disposable, thus avoiding the need for surface cleaning and the problem of memory
effects.
Figure 1.3: Screen printed carbon electrode consists of working electrode; counter
electrode and reference electrode
The production of the SPEs comes with different ink on planar ceramic or
plastic supports. SPEs can be modified by adding versatile substances of different
nature such as nanomaterial, enzymes, self assembled monolayer (SAM), polymers and
complexing agents (Honeychurch et al.,2012).
1.3 Problem Statement
Development of heavy metal ions detection and quantification in the environment is
crucial to our present society. There is an increasing need for analytical systems that
deliver fast and reliable data in the development of novel sensors. Sensitivity
enhancement and lowering of the detection limit of heavy metal ions are the effort
neede to be focused on.
© COPYRIG
HT UPM
4
Nanoparticles is receiving particular attention in sensor and biosensor application, for
it’s excellent conducting ability and capability in increasing sensitivity. Nanoparticles;
have shown a great potential application in a wide range of existing and emerging
technologies. Nanoparticles are used in heavy metals detection in order to avoid the
previous used of mercury electrodes due to toxicity of mercury.
In this study SiNW’s was used as the nanomaterial because it have excellent
conducting capability and high surface-to-volume ratio to enhance the detection limit.
Selectivity is another important issue in heavy metals detection. Macrocyclic molecules
as ionophore can be the solution to this problem, because ionophore provides binding
sites for interaction with metal ions. In this research, Hg2+ and Cd2+ were detected by
electrochemical method using SiNW’s modified SPCE. The detection limit of Hg2+ also
much lower when modified SPCE with SiNW’s/ionophore.
1.4 Objective of the studies
1.4.1 General Objective
The obective of this research is to develop a sensor for selective and specific detection
and quantification of toxic metal ions such as Hg2+ and Cd2+ ions in environmental
samples by utilizing silicon nanowires (SiNW’s).
1.4.2 Specific Objective
1. To modify the screen printed carbon electrode (SPCE) for selective and specific
detection of heavy metal ions Hg2+ and Cd2+ by utilizing silicon nanowires
(SiNW’s).
2. To optimize the deposition time, deposition potential, supporting electrolyte and
characterize with SEM the modified SPCE.
3. To test the fabricate sensor on sea water samples.
© COPYRIG
HT UPM
47
REFERENCES
Abdul Rashid, J. I., Abdullah, J., Yusof, N. A., & Hajian, R. (2013). The Development
of Silicon Nanowire as Sensing Material and Its Applications. Journal of
Nanomaterials, 1–16.
Afkhami, A., Soltani-Felehgari, F., Madrakian, T., Ghaedi, H., & Rezaeivala, M.
(2013). Fabrication and application of a new modified electrochemical sensor
using nano-silica and a newly synthesized Schiff base for simultaneous
determination of Cd(II), Cu2+ and Hg2+ ions in water and some foodstuff samples.
Analytica Chimica Acta, 771, 21–30.
Ahmar, H., Fakhari, A. R., Tabani, H., & Shahsavani, A. (2013). Optimization of
electromembrane extraction combined with differential pulse voltammetry using
modified screen-printed electrode for the determination of sufentanil.
Electrochimica Acta, 96, 117–123.
Bagheri, H., Afkhami, A., Khoshsafar, H., Rezaei, M., & Shirzadmehr, A. (2013).
Simultaneous electrochemical determination of heavy metals using a
triphenylphosphine/MWCNTs composite carbon ionic liquid electrode. Sensors
and Actuators B: Chemical, 186, 451–460.
Belluzo, M. S., Ribone, M. É., & Lagier, C. M. (2007). Assembling Amperometric
Biosensors for Clinical Diagnostics. Sensors, 8(3), 1366–1399.
Bi, X., Agarwal, A., Balasubramanian, N., & Yang, K.-L. (2008). Tripeptide-modified
silicon nanowire based field-effect transistors as real-time copper ion sensors.
Electrochemistry Communications, 10(12), 1868–1871.
Buffle, J., & Tercier-Waeber, M.-L. (2005). Voltammetric environmental trace-metal
analysis and speciation: from laboratory to in situ measurements. TrAC Trends in
Analytical Chemistry, 24(3), 172–191.
Cammmann,G. G., Guilbault,E. A., Hal, H. K., & Wolfbies,).O. S., The Cambridge
Definition of Chemical Sensord, Cambridge Workshop in Chemical Sensors and
Biosensors, Cambridge University Press: New York,1996.
Chen,Z., Pourabedi, Z., & Hibbert, D. B. (1999). Stripping Voltammetry of Pb(II),
Cu(II), and Hg(II) at a Nafion - Coated Glassy Carbon Electrode Modified by
Neutral Ionophores, Microchimica Acta, 964–96.
Compton, R. G., & Banks, C. E. (Eds.). (2007), Cyclic Voltammetry at
Macroelectrodes in Understanding Voltammetry. Singapore: World Scientific
Publishing Co. Pte Ltd.
© COPYRIG
HT UPM
48
Cui, Y. and C. M. Lieber (2001). Functional nanoscale electronic devices assembled
using silicon nanowire building blocks. Science 291(5505), 851-853.
Domínguez Renedo, O., & Arcos Martínez, M. J. (2007). Anodic stripping
voltammetry of antimony using gold nanoparticle-modified carbon screen-printed
electrodes. Analytica Chimica Acta, 589(2), 255–60.
Domínguez-Renedo, O., Ruiz-Espelt, L., García-Astorgano, N., & Arcos-Martínez, M.
J. (2008). Electrochemical determination of chromium(VI) using metallic
nanoparticle-modified carbon screen-printed electrodes. Talanta, 76(4), 854–8.
Enzhong, T.; Penggang, Y.; Xiufeng, L.; Hongyan, Z.; Lin G. A novel surface-
enhanced Raman scattering nanosensor for detecting multiple heavy metal ions
based on 2-mercaptoisonicotinic acid functionalized gold nanoparticles.
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy 2012, 97,
1007–1012.
Garcia, C. A. B.; Ju´ nior, L. R.; Neto, G. O. J. Pharm. Biomed. Anal. 2003, 31, 11–18.
Gu, T., Bu, L., Huang, Z., Liu, Y., Tang, Z., Liu, Y., … Luo, S. (2013). Dual-signal
anodic stripping voltammetric determination of trace arsenic(III) at a glassy
carbon electrode modified with internal-electrolysis deposited gold nanoparticles.
Electrochemistry Communications, 33, 43–46.
Hassan, K.; Mir, F.M.; Yadollah, Y.; Mojtaba, S. On-line reconcentration and
simultaneous determination of heavy metal ions by inductively coupled plasma-
atomic emission spectrometry. Analytica Chimica Acta 2004, 509, 89–94.
Hassan, S. S., Solangi, A. R., Kazi, T. G., Kalhoro, M. S., Junejo, Y., Tagar, Z. A., &
Kalwar, N. H. (2012). Nafion stabilized ibuprofen–gold nanostructures modified
screen printed electrode as arsenic(III) sensor. Journal of Electroanalytical
Chemistry, 682, 77–82.
He, X., Chen, L., Xie, X., Su, Z., Qin, C., Liu, Y., … Luo, Y. (2011). Square wave
anodic stripping voltammetric determination of lead(II) using a glassy carbon
electrode modified with a lead ionophore and multiwalled carbon nanotubes.
Microchimica Acta, 176(1-2), 81–89.
Hezard, T., Fajerwerg, K., Evrard, D., Collière, V., Behra, P., & Gros, P. (2012).
Influence of the gold nanoparticles electrodeposition method on Hg(II) trace
electrochemical detection. Electrochimica Acta, 73, 15–22.
Hezard, T., Fajerwerg, K., Evrard, D., Collière, V., Behra, P., & Gros, P. (2012).
Influence of the gold nanoparticles electrodeposition method on Hg(II) trace
electrochemical detection. Electrochimica Acta, 73, 15–22.
Honeychurch, K. C. (2012). Screen-printed Electrochemical Sensors and Biosensors
for Monitoring Metal Pollutants. Insciences Journal, 2, 1–51.
© COPYRIG
HT UPM
49
Ilaria Palchetti , Christa Upjohn, A. P. F. T. & M. M. (2000). Disposable Screen-
Printed Electrodes ( Spe ) Mercury- Free for Lead Detection. Taylor & Francis,
33(7), 37–41.
Injang, U., Noyrod, P., Siangproh, W., Dungchai, W., Motomizu, S., & Chailapakul, O.
(2010). Determination of trace heavy metals in herbs by sequential injection
analysis-anodic stripping voltammetry using screen-printed carbon nanotubes
electrodes. Analytica Chimica Acta, 668(1), 54–60.
Injang, U., Noyrod, P., Siangproh, W., Dungchai, W., Motomizu, S., & Chailapakul, O.
(2010). Determination of trace heavy metals in herbs by sequential injection
analysis-anodic stripping voltammetry using screen-printed carbon nanotubes
electrodes. Analytica Chimica Acta, 668(1), 54–60.
Jiang, L., Wang, Y., Ding, J., Lou, T., & Qin, W. (2010). An ionophore–Nafion
modified bismuth electrode for the analysis of cadmium(II). Electrochemistry
Communications, 12(2), 202–205.
John H. Duffus, (2002). HEAVY METALS - A MEANINGLESS TERM ? (IUPAC
Technical Report) (IUPAC Technical Report ), 74(5), 793–807.
Juang, R.-S., & Shao, H.-J. (2002). A simplified equilibrium model for sorption of
heavy metal ions from aqueous solutions on chitosan. Water Research, 36(12),
2999–3008.
Kwon, D. H., An, H. H., Kim, H.-S., Lee, J. H., Suh, S. H., Kim, Y. H., & Yoon, C. S.
(2011). Electrochemical albumin sensing based on silicon nanowires modified by
gold nanoparticles. Applied Surface Science, 257(10), 4650–4654.
Laschi, S., Palchetti, I., & Mascini, M. (2006). Gold-based screen-printed sensor for
detection of trace lead. Sensors and Actuators B: Chemical, 114(1), 460–465.
Li, B. L., Wu, Z. L., Xiong, C. H., Luo, H. Q., & Li, N. B. (2012). Anodic stripping
voltammetric measurement of trace cadmium at tin-coated carbon paste electrode.
Talanta, 88, 707–10.
Li, J., Guo, S., Zhai, Y., & Wang, E. (2009). Nafion–graphene nanocomposite film as
enhanced sensing platform for ultrasensitive determination of cadmium.
Electrochemistry Communications, 11(5), 1085–1088.
Luo, X., Morrin, A., Killard, A. J., & Smyth, M. R. (2006). Application of
Nanoparticles in Electrochemical Sensors and Biosensors. Electroanalysis, 18(4),
319–326.
M. Brand, I. Eshkenazi, E. Kirowa-Eisnar, The silver electrode in square wave anodic
stripping voltammetry. Determination of Pb(II) without removal of oxygen, Anal.
Chem. 69 (1997) 4660–4664.
© COPYRIG
HT UPM
50
Mashhadizadeh, M. H., & Khani, H. (2010). Sol-Gel-Au nano-particle modified carbon
paste electrode for potentiometric determination of sub ppb level of Al(III).
Analytical Methods, 2(1), 24.
Morton, J., Havens, N., Mugweru, A., & Wanekaya, A. K. (2009). Detection of Trace
Heavy Metal Ions Using Carbon Nanotube- Modified Electrodes. Electroanalysis,
21(14), 1597–1603.
P. Masawat, S. Liawruangrath, J.M. Slater, Flow injection measure- ment of lead using
mercury-free disposable gold-sputtered screen- printed carbon electrodes (SPCE),
Sens. Actuators B: Chem. 91 (2003) 52–59.
Pan, D., Wang, Y., Chen, Z., Lou, T., & Qin, W. (2009). Nanomaterial / Ionophore-
Based Electrode for Anodic Stripping Voltammetric Determination of Lead : An
Electrochemical Sensing Platform toward Heavy Metals, 81(12), 5088–5094.
Pan, D., Wang, Y., Chen, Z., Yin, T., & Qin, W. (2009). Fabrication and
Characterization of Carbon Nanotube-Hydroxyapatite Nanocomposite:
Application to Anodic Stripping Voltammetric Determination of Cadmium.
Electroanalysis, 21(8), 944–952.
Philips, M. F., Gopalan, A. I., & Lee, K.-P. (2012). Development of a novel cyano
group containing electrochemically deposited polymer film for ultrasensitive
simultaneous detection of trace level cadmium and lead. Journal of Hazardous
Materials, 237-238, 46–54.
Rahman, N. A., Yusof, N. A., Amirah, N., Maamor, M., Mariam, S., & Noor, M.
(2012). Development of Electrochemical Sensor for Simultaneous Determination
of Cd ( II ) and Hg ( II ) Ion by Exploiting Newly Synthesized Cyclic Dipeptide,
7(2017), 186–196.
Renedo, O. D., Alonso-Lomillo, M. a, & Martínez, M. J. A. (2007). Recent
developments in the field of screen-printed electrodes and their related
applications. Talanta, 73(2), 202–19.
Rivas, G. a, Rubianes, M. D., Rodríguez, M. C., Ferreyra, N. F., Luque, G. L., Pedano,
M. L., … Parrado, C. (2007). Carbon nanotubes for electrochemical biosensing.
Talanta, 74(3), 291–307.
Sanllorente-Méndez, S., Domínguez-Renedo, O., & Arcos-Martínez, M. J. (2010).
Immobilization of acetylcholinesterase on screen-printed electrodes. Application
to the determination of arsenic(III). Sensors (Basel, Switzerland), 10(3), 2119–28.
Shao, M., Ma, D. D. D., & Lee, S.-T. (2010). Silicon Nanowires - Synthesis, Properties,
and Applications. European Journal of Inorganic Chemistry, 2010(27), 4264–
4278.
© COPYRIG
HT UPM
51
Somerset, V., Leaner,J., Mason, R., Iwuoha, E.,& Morrin, A.(2010).Development and
application of a poly(2,2’-dithiodianiline) (PDTDA)-coated screen-printed
carbon electrode in inorganic mercury determination. Electrochimica Acta, 55,
4240-4246.
Song, W., Zhang, L., Shi, L., Li, D.-W., Li, Y., & Long, Y.-T. (2010). Simultaneous
determination of cadmium(II), lead(II) and copper(II) by using a screen-printed
electrode modified with mercury nano-droplets. Microchimica Acta, 169(3-4),
321–326.
Su, S., He, Y., Song, S., Li, D., Wang, L., Fan, C., & Lee, S.-T. (2010). A silicon
nanowire-based electrochemical glucose biosensor with high electrocatalytic
activity and sensitivity. Nanoscale, 2, 1704–1707.
Su, S., He, Y., Zhang, M., Yang, K., Song, S., Zhang, X., Lee, S. T. (2008). High-
sensitivity pesticide detection via silicon nanowires-supported
acetylcholinesterase - based electrochemical sensors. Applied Physics Letters,
93(2008),2006-2009.
Tahir, T. F., Salhin, A., Saad, B., & Ab Ghani, S. (2012). The 4-(Dimethylamino)
benzaldehyde-4-ethylthiosemicarbazone as Ionophore for Mercury(II) Solid State
Selective Electrode. Electroanalysis, 24(6).
Tiean, G.; Lijuan, B.; Zhao, H.; Yan, L.; Zhiyong, T.; Ying, L.; Siyu, H.; Qingji, X.;
Shouzhuo, Y.; Xinman, T.; Xubiao, L.; Shenglian, L. Dual-signal anodic
stripping voltammetric determination of trace arsenic(III) at a glassy carbon
electrode modified with internal-electrolysis deposited gold nanoparticles.
Electrochemistry Communications 2013, 33, 43–46.
Uthaitip, I.; Peeyanun, N.; Weena S.; Wijitar D.; Shoji, M.; Orawon C. Determination
of trace heavy metals in herbs by sequential injection analysis-anodic stripping
voltammetry using screen-printed carbon nanotubes electrodes. Analytica
Chimica Acta 2010, 668, 54–60.
Wei, Y., Yang, R., Yu, X.-Y., Wang, L., Liu, J.-H., & Huang, X.-J. (2012). Stripping
voltammetry study of ultra-trace toxic metal ions on highly selectively adsorptive
porous magnesium oxide nanoflowers. The Analyst, 137(9), 2183–91.
Wei,Y., Gao, C., Meng, F., Li, H., Wang, L., Liu, J., & Huang, X. (2012). SnO 2 /
Reduced Graphene Oxide Nanocomposite for the Simultaneous Electrochemical
Detection of Cadmium ( II ), Lead ( II ), Copper ( II ), and Mercury ( II ): An
Interesting Favorable Mutual Interference, (Ii), 1034–1041.
Wen, J.Y.; Yang, L.; Gu, R.; Hong, Q.L.; Nian, B.L. Determination of cadmium(II) by
square wave anodic stripping voltammetry using bismuth–antimony film
electrode. Sensors and Actuators B 2012, 166– 167, 544– 548.
© COPYRIG
HT UPM
52
Wonsawat, W., Chuanuwatanakul, S., Dungchai, W., Punrat, E., Motomizu, S., &
Chailapakul, O. (2012). Graphene-carbon paste electrode for cadmium and lead
ion monitoring in a flow-based system. Talanta, 100, 282–9.
Y. Bonfil, M. Brand, E. Kirowa-Eisner, Trace determination of mercury by anodic
stripping voltammetry at the rotating gold electrode, Anal. Chim. Acta 424 (2000)
65–76
Yan, S., He, N., Song, Y., Zhang, Z., Qian, J., & Xiao, Z. (2010). A novel biosensor
based on gold nanoparticles modified silicon nanowire arrays. Journal of
Electroanalytical Chemistry, 641(1-2), 136–140.
Yi, W. J., Li, Y., Ran, G., Luo, H. Q., & Li, N. B. (2012). Determination of cadmium(II)
by square wave anodic stripping voltammetry using bismuth–antimony film
electrode. Sensors and Actuators B: Chemical, 166-167, 544–548.
Yu, L.P. Cloud Point Extraction Preconcentration Prior to High-Performance Liquid
Chromatography Coupled with Cold Vapor Generation Atomic Fluorescence
Spectrometry for Speciation Analysis of Mercury in Fish Samples. J. Agric. Food
Chem 2005, 53, 9656-9662.
Zheng, D., Vashist, S., Dykas, M., Saha, S., Al-Rubeaan, K., Lam, E., … Sheu, F.-S.
(2013). Graphene versus Multi-Walled Carbon Nanotubes for Electrochemical
Glucose Biosensing. Materials, 6(3), 1011-1127.