X:\P 2014\1406 PFC CAMBIE\03 docs\4.0 field services\05 shift internal\07 instructions\SI-35-R1 [ECR-08, IDSI-03 AMENITY WASHROOM #131] - IN PROGRESS\181204 SI-35-R1 [ECR-08, IDSI-03 AMENITY WASHROOM #131].docx Project: HAWTHORNE 4988 Cambie Street, Vancouver B.C. SHIFT No: 1406 Owner: Pennyfarthing QE Park Properties 100-1450 Creekside Drive Vancouver B.C. V6J 5B3 Attn: Kevin Hussey Contractor: Performance Construction Suite 1150-21331 Gordon Way, Richmond, BC V6W 1J9 Attn: Andree Godler Date of Issue: December 4, 2018 Pages: 6 By: EMAIL SITE INSTRUCTION SI-35-R1 Name SI-35-R1 [ECR-08, IDSI-03 AMENITY WASHROOM #131] Reason Further information to instruction SI-35. The following instructions are issued for clarification only and in accordance with the terms of the contract and on the assumption that both the Contract Price and Contract Time are not affected. Proceeding with the work in accordance with these instructions indicates the Contractors acknowledgement that there will be no change in the Contract Price or Contract Time. The Contractor shall notify the Prime Consultant prior to the commencement of the work if he believes that this instruction affects either the Contract Price or Contract Time. Item: Description: Pages: 35.03 35.04 ECR-08 IDSI-03 AMENITY WASHROOM AND KITCHEN REVISIONS 1 4 End of Site Instruction SI-35-R1 Prepared By: Heather Klassen B.Arch.Sci. Distribution: Owner Kevin Hussey 604 734 8443 [email protected] Owner Matt Kolec 604 734 8443 [email protected] Project Manager Paul Warwick 604 721 6034 [email protected] Site Superintendent Andree Godler 604 649 6400 [email protected] Project Architect Cameron Halkier 604 988 7501 [email protected] Certified Professional Susana Chui 604 800 9822 [email protected] Building Envelope Pat Cuthbert 604 946 9910 [email protected] Structural Engineer Thomas Leung 604 873 1768 [email protected] Mechanical Engineer Richard Corra 604 888 7779 [email protected] Electrical Engineer Blake Shine 604 475 6725 [email protected] Landscape Architect Richard O’Connor 604 684 4611 [email protected] Interior Design Cristina Oberti 604 697 0363 [email protected] Geotechnical Engineer Matt Kokan 604 439 0922 [email protected]
6

SITE INSTRUCTION SI -35-R1 · Mechanical Engineer Richard Corra 604 888 7779 [email protected] Electrical Engineer Blake Shine 604 475 6725 [email protected] Landscape Architect

Aug 16, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: SITE INSTRUCTION SI -35-R1 · Mechanical Engineer Richard Corra 604 888 7779 richard.corra@rpeng.ca Electrical Engineer Blake Shine 604 475 6725 blake@opaleng.com Landscape Architect

X:\P 2014\1406 PFC CAMBIE\03 docs\4.0 field services\05 shift internal\07 instructions\SI-35-R1 [ECR-08, IDSI-03 AMENITY WASHROOM #131] - IN PROGRESS\181204 SI-35-R1 [ECR-08, IDSI-03 AMENITY WASHROOM #131].docx

Project: HAWTHORNE 4988 Cambie Street, Vancouver B.C.

SHIFT No: 1406

Owner: Pennyfarthing QE Park Properties 100-1450 Creekside Drive Vancouver B.C. V6J 5B3 Attn: Kevin Hussey

Contractor: Performance Construction Suite 1150-21331 Gordon Way, Richmond, BC V6W 1J9 Attn: Andree Godler

Date of Issue: December 4, 2018

Pages: 6 By: EMAIL

SITE INSTRUCTION SI-35-R1 N a m e S I - 3 5 - R 1 [ E C R - 0 8 , I D S I - 0 3 A M E N I T Y W A S H R O O M # 1 3 1 ]

R e a s o n Further information to instruction SI-35.

The following instructions are issued for clarification only and in accordance with the terms of the contract and on the assumption that both the Contract Price and Contract Time are not affected. Proceeding with the work in accordance with these instructions indicates the Contractors acknowledgement that there will be no change in the Contract Price or Contract Time. The Contractor shall notify the Prime Consultant prior to the commencement of the work if he believes that this instruction affects either the Contract Price or Contract Time.

I t e m : D e s c r i p t i o n : P a g e s :

35.03 35.04

ECR-08 IDSI-03 AMENITY WASHROOM AND KITCHEN REVISIONS

1 4

End of Site Instruction SI-35-R1

Prepared By: Heather Klassen B.Arch.Sci.

Distribution: Owner Kevin Hussey 604 734 8443 [email protected] Owner Matt Kolec 604 734 8443 [email protected] Project Manager Paul Warwick 604 721 6034 [email protected] Site Superintendent Andree Godler 604 649 6400 [email protected] Project Architect Cameron Halkier 604 988 7501 [email protected] Certified Professional Susana Chui 604 800 9822 [email protected] Building Envelope Pat Cuthbert 604 946 9910 [email protected] Structural Engineer Thomas Leung 604 873 1768 [email protected] Mechanical Engineer Richard Corra 604 888 7779 [email protected] Electrical Engineer Blake Shine 604 475 6725 [email protected] Landscape Architect Richard O’Connor 604 684 4611 [email protected] Interior Design Cristina Oberti 604 697 0363 [email protected] Geotechnical Engineer Matt Kokan 604 439 0922 [email protected]

Page 2: SITE INSTRUCTION SI -35-R1 · Mechanical Engineer Richard Corra 604 888 7779 richard.corra@rpeng.ca Electrical Engineer Blake Shine 604 475 6725 blake@opaleng.com Landscape Architect

[email protected] 1340 Barberry Dr, Port Coquitlam, BC, V3B 1G3 604-475-6725 Page 1

Electrical Change Request ECR#008

Date: 22 November 2018

Project: Hawthorne, Vancouver, BC Opal Project # SAI-01

To: Shift Architecture – Heather Klassen

CC: Pennyfarthing Development Group – Kevin Hussey

The following is a description of the proposed change to the contract documents. The electrical contractor shall submit a breakdown of

material and labour costs associated with each section of this proposed change. Make construction team aware of any impact on the

construction schedule resulting from this change. Do not proceed with the work described herein until approved.

Prepared by: Blake Shine

1. DRAWING E4.0 – Amenity Room

1.1 Add connection and manual motor starter for 120V 0.5HP SANI-1 Saniflo system in

washroom 131. Provide 1P-20A breaker and 2#12 wire. Circuit to Panel 2H.

1.2 Add connection and manual motor starter for 120V 0.4 HP SANI-2 Saniflo system

in Amenity Room 130. Provide 1P-20A breaker and 2#12 wire. Circuit to Panel 2H.

Page 3: SITE INSTRUCTION SI -35-R1 · Mechanical Engineer Richard Corra 604 888 7779 richard.corra@rpeng.ca Electrical Engineer Blake Shine 604 475 6725 blake@opaleng.com Landscape Architect

CO CRISTINA OBERTI INTERIOR DESIGN INC. (Member of the Interior Design Institute of BC) 1460-1188 West Georgia St., Vancouver, BC V6E 4A2 Tel. 604.697.0363 Fax. 604.697.0030

ID SITE INSTRUCTION #: 3 PROJECT: HAWTHORNE SENT TO: Heather Klassen Shift Architecture Inc. 200- 1000 West 3rd Street Vancouver, BC V7P 3J6 Date 11-29-2018 Project No.: 2016-011 The Contractor is responsible for obtaining clarification on any items outlined in the site instruction that are deemed unclear or unnecessary. The site instruction is not an authorization for additional work or costs. If the Contractor believes that this instruction affects the Contract Price or Contract Time, the Contractor shall promptly notify the consultant and coordinating Professional. COMMENTS: A) Amenity Washroom and Kitchen Revisions

A) Please note the following areas have been revised as per Architectural changes caused by plumbing issues on site:

a. Amenity washroom door and plumbing locations b. Amenity kitchen c. Amenity entry door and glazing

Please see SK-8-10 for revisions. If you have any questions, please call. Thank you, Regards, CRISTINA OBERTI INTERIOR DESIGN INC. per: Jennifer Schwingboth, DID Interior Designer

Page 4: SITE INSTRUCTION SI -35-R1 · Mechanical Engineer Richard Corra 604 888 7779 richard.corra@rpeng.ca Electrical Engineer Blake Shine 604 475 6725 blake@opaleng.com Landscape Architect

SHEET TITLE:

CHECKED BY:

SCALE:

DATE:

DRAWN BY:

SK-8

NO.

JF

NOTE: This drawing is an instrument of service andmust only be used in conjunction with the ProjectManual and all other drawings, specifications,correspondence and information pertinent to the project.The Contractor shall verify references, datum anddimensions on site and request clarification, fromCristina Oberti Interior Design Inc., of any discrepanciesor omissions as soon as they are discovered prior toexecution of any work. The Contractor is responsible forthe method of execution and for compliance of all workswith the requirements of the Authorities HavingJurisdiction. Written architectural dimensions takeprecedence in the coordination of information. Do notscale drawings.

CO

DATE ISSUE / REVISION

CRISTINA OBERTI INTERIOR DESIGN INC.

PROJECT NO: 2016-11

PROJECT TITLE:

INTERIOR DESIGNER:

CO

Copyright: This drawing, including the designconcepts, is an instrument of service and exclusiveproperty of Cristina Oberti Interior Design Inc.It cannot be used or reproduced without knowledgeand expressed consent of Cristina Oberti InteriorDesign Inc.

1460-1188 WEST GEORGIA ST.VANCOUVER, BC V6E 4A2

HAWTHORNE4976-5010 CAMBIE STREETVANCOUVER, BC, CANADA

COMMON AREALEVEL 1 FINISHES PLAN

SEPTEMBER 2016

Tel. 604.697.0363Fax [email protected]

1/4" = 1'-0"

NOV. 18 2016 ISSUED FOR 50% PROGRESS

DEC. 21 2016 ISSUED FOR 65% PROGRESS

FEB. 3 2017 ISSUED FOR CLIENTS REVIEW

FEB. 17 2017 ISSUED FOR 75% PROGRESS

JUNE 30 2017 ISSUED FOR TENDER

JULY 31 2017 ISSUED FOR TENDER/BP SET

JULY 4 2018 ISSUED FOR CONSTRUCTION

W/D

W/D

RE

F.

W/D

UP

UP

W/D

W/D

W/D

DW

REF.

DN

DW

RE

F.

DW

REF.WO/SO

DW

WO

/SO

RE

F.

WO

/SO

WO

/SO

WO/SO

DN

LOBBY

100b

VESTIBULE

100a

AMENITY

130

TYPE A3

102

STAIR 1

S1-01

STAIR 2

S2-01

ELEC.

120

CORRIDOR

110

STAIR 3S3-01

DINING

STORAGE

ENTRY

DEN

BATH

MASTERBEDROOM

DINING

LIVING

W.I.C.

ENTRY

STORAGE

ENTRY

MASTERBEDROOM

BEDROOMENTRY

ENSUITE

W.I.C.

BATH

DININGLIVING

KITCHEN

ENTRY

MASTERBEDROOM

BATH

DINING LIVING

STORAGEW.I.C.

KITCHEN

BATH

DINING MASTERBEDROOM

LIVING

ENTRY

LINEN

KITCHEN

MASTERBEDROOM

ENTRY

ENSUITE

W.I.C.

ENSUITE

W.I.C.KITCHEN

CLASS "B"

DD

STORAGE

BEDROOM

INDICATES WATERCURTAIN C/W TEMPERED

GLAZING (REFER TOCODE REPORT)

CORRIDOR

112

STORAGE

132

CORRIDOR

111

TYPE A4

103

TYPE B9

101

TYPE A6

107

RWLDN

RWLFA

RWLDN

RWLDN

RWLDN

RWLDN

RWLFA

RWLDN

RWLDN

RWLFA

RWLFA

RWLDN

RWL

RWLDN

RWLFA

RWLDN

RWLDN

RWLDN

DN

RWLDN

RWLDN

3 BAY PANEL 3 BAY PANEL 3 BAY PANEL

MAILBOXES/RECYCLING BINRECESSED INTO WALL

LEDGE

INSTALLSCHLUTERTREP-G-B INBETWEENRAMP TILES

INSTALL SCHLUTERTREP-G-B ON TILE STAIRS

"WP1" LAYOUT/DESIGNAS PER ELEVATION 5

ON ID-9

INSTALLSCHLUTERTREP-G-B INBETWEENRAMP TILES

"WP1" LAYOUT/DESIGNAS PER ELEVATION 2

ON ID-9

DN

10.0

%

ELEVATORLOBBY

SEALEDCONCRETE

SEALEDCONCRETE

SEALEDCONCRETE

REFER TO SHEETID-10 FOR ELEVATORCAB DRAWINGS AND

SPECIFICATIONS

24"INTEGRATED

U/C REF.

AMENITYWASHROOM

SEALEDCONCRETE

RA

MP

SEALEDCONCRETE

24"INTEGRATEDDISHWASHER

WP1

WP1

WP1

WP1WP1

WP1

S1

WP1

S1

B2 F1

V1

B2 F1

B2

V1

B2 F1

V1

B1 C1

P1

WP1

B1 C1

P1

B1 C1

P1

P2

P2

P2

B3 F2T1P1

B1 F3

V1

T2

WP1

B1 F3

P1

WP1

P2

P2

WP1

WP1

F1F1WP1

WP12

ID-9

3ID-9

1ID-9

4ID-9

5ID-9

10AID-10

8ID-10

9ID-10

7ID-9

6ID-9

10ID-10

C

CA

CB

PC

PD

C1 2

3

4

C2

F1

B1

B2

S1

P1

P2

WP1

T1

C1

B3

F3

V1

F2

T2

3

3

FINISHES NOTESF1. PAINTING WORK TO BE DONE IN ACCORDANCE TO THE LATEST EDITION OF THE CANADIAN PAINTINGCONTRACTORS ASSOCIATION AND MASTER PAINTERS ASSOCIATION OF BRITISH COLUMBIA.

F2. ALL DRYWALL TO BE TREATED AND SEALED TO SUIT WALL FINISHES SPECIFIED.

F3. PROVIDE 1 COAT PRIMER AND 2 FINISH COATS OF SPECIFIED COLOR FOR PAINTING NEW GWB PARTITIONS ORNEWLY PATCHED PARTITIONS. FOR EXISTING PARTITIONS, CLEAN AND SAND EXISTING SURFACES AND PROVIDE 2FINISH COATS. PROVIDE BRUSH CUTS OF ALL PAINTS PRIOR TO ORDERING AND APPLYING PAINTS.

F4. REMOVE SUB-SURFACE RIDGES AND BUMPS ON FLOOR. FILL LOW SPOTS, JOINTS AND HOLES AND OTHERDEFECTS WITH MANUFACTURERS RECOMMENDED PRODUCT TO ENSURE SURFACES ARE FLAT TO WITHIN 1/8" IN 3'-0".

F5. WOOD: 1 COAT SEALER, 2 COATS SEMI-GLOSS LACQUER.

F6. ALL DOORS TO RECEIVE FLOOR MOUNTED DOOR STOPS UNLESS NOTED OTHERWISE. FINISH TO MATCHHARDWARE.

F7. ALL FLOOR TRANSITIONS BETWEEN CARPET AND FLOOR TILES TO INCLUDE SCHLUTER SYSTEM, RENO-U-AEU(SATIN ANODIZED ALUMINUM FINISH); SMOOTH TRANSITION BETWEEN FLOOR COVERINGS OF DIFFERENT HEIGHTS.ITEM NUMBER TO BE SELECTED ACCORDING TO SPECIFIED TILE THICKNESS.

F8. ALL TILES TO BE INSTALLED AS PER THE "TERRAZZO, TILE AND MARBLE ASSOCIATION OF CANADA SPECIFICATIONGUIDE 09300 TILE INSTALLATION MANUAL" LATEST EDITION. GROUT JOINTS TO BE 1/8" (3MM). INSTALL TILES WITH LOWVOC ADHESIVES.

F9. TILE FLOORS TO INCLUDE CRACK ISOLATION (ANTI-FRACTURE) MEMBRANE USING ELASTOMERIC SHEETS.

F10. TYPICAL DRYWALL CEILING TO BE PAINTED: MANU.: BENJAMIN MOORE COLOR: OC-152/PM-1 SUPER WHITE PRODUCT: ULTRA SPEC 500, INTERIOR FLAT PRODUCT CODE: K536 MPI: QUALIFIES FOR 143 X-GREEN FINISH: FLAT GLOSS RANGE: 1.5-3.5% FEATURES: ZERO VOC, MPI + LEED APPROVED CONTACT: JODY REPPERT 604-607-3410

F11. TYPICAL PAINTED METAL DOORS & DOOR FRAMES TO BE PAINTED: MANU.: BENJAMIN MOORE COLOR: 2134-30 IRON MOUNTAIN PRODUCT: ULTRA SPEC 500, INTERIOR SEMI-GLOSS PRODUCT CODE: K539 MPI: QUALIFIES FOR 54 X-GREEN FINISH: SEMI-GLOSS GLOSS RANGE: 20-35% FEATURES: ZERO VOC, MPI + LEED APPROVED CONTACT: JODY REPPERT 604-607-3410

F12. TYPICAL ELEVATOR DOORS AND FRAMES TO BE PAINTED: MANU.: BENJAMIN MOORE COLOR: 2134-30 IRON MOUNTAIN PRODUCT: ULTRA SPEC 500, INTERIOR SEMI-GLOSS PRODUCT CODE: K539 MPI: QUALIFIES FOR 54 X-GREEN FINISH: SEMI-GLOSS GLOSS RANGE: 20-35% FEATURES: ZERO VOC, MPI + LEED APPROVED CONTACT: JODY REPPERT 604-607-3410EXCEPT FOR LEVEL 1 ELEVATOR DOOR AND FRAME TO BE STAINLESS STEEL.

F13. ALL CARPET TO BE INSTALLED WITH CARPET CUSHION, DOUBLE GLUE DOWN INSTALLATION TO CONCRETE SLAB,USING MANUFACTURERS RECOMMENDED ADHESIVE AND METHOD OF APPLICATION.

F14. ALL SPECIFICATIONS OUTLINES IN THESE SPECIFICATIONS SHALL NOT BE CHANGED WITHOUT APPROVAL FROMCRISTINA OBERTI INTERIOR DESIGN INC. SHOULD THE DEVELOPER OR THE GENERAL CONTRACTOR CHANGE ANYFINISHES IN THESE SPECIFICATIONS, CRISTINA OBERTI INTERIOR DESIGN IS NOT RESPONSIBLE FOR THESPECIFICATIONS UNLESS APPROVED BY CRISTINA OBERTI INTERIOR DESIGN INC.

F15. MOVEMENT JOINTS REQUIRED AS PER TTMAC GUIDELINES FOR FLOOR TILES.

F16. EXIT STAIRS TO INCLUDE TACTILE WARNING STRIPS CONFORMING TO THE BCBC 2012 SECTION 3.8.3.11; A 725MMTO 775MM WIDE TACTILE WARNING SURFACE SHALL BE PROVIDED FOR THE FULL WIDTH OF THE STAIR THAT IS ONETREAD WIDTH BACK FROM THE TOP RISER AND NOT MORE THAN 3MM ABOVE OR BELOW THE SURROUNDING FLOORSURFACE. TO BE SLIP RESISTANT, DURABLE, DETECTABLE BY WALKING UPON AS BEING DIFFERENT FROM THESURROUNDING FLOORING AND IN A CONTRASTING COLOR TO THE SURROUNDING FLOORING. FOR STAIRCONSTRUCTION AND RISER DETAIL REFER TO ARCHITECTURAL DRAWINGS. TACTILE STRIP CONTRASTING COLOR TOBE.: MFR.: BENJAMIN MOORE COLOR: 2022-30 BRIGHT YELLOW UNLESS NOTED OTHERWISE.

F17. ALL ADHESIVES, SEALANTS, PAINTS AND COATINGS DO NOT EXCEED MAXIMUM VOC LIMITS AS PER LEED 2009AND COMPLIANT WITH EQc4.1.

F18. ALL CARPET TO BE INSTALLED WITH CARPET CUSHION, DOUBLE GLUE DOWN INSTALLATION TO CONCRETE SALBUSING MANUFACTURERS RECOMMENDED ADHESIVE AND METHOD OF APPLICATION.

F19. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR TYPICAL CEILING HEIGHT UNLESS NOTEDOTHERWISE.

F20. WOOD PANELING TO TURN 90 DEGREES IN SIDE CORRIDORS FOR 3" +/-. TO RECEIVE PAINTED GYPSUM BOARDON INTERSECTING WALLS WHERE INTERNAL CORNER INTERSECTION NOT APPLICABLE.

F21. TYPICAL FLOORING TO BE PAINTED SEALED CONCRETE UNLESS NOTED OTHERWISE.

F22. MILLWORK PRODUCTS MUST BE NAUF (NO ADDED UREA FORMALDEHYDE) NON TROPICAL WOOD MUST BEUSED OR FSC CERTIFIED TROPICAL WOOD.

GENERAL NOTESC1. REFER TO ARCHITECTURAL DRAWINGS FOR ALL LOCATIONS ANDDIMENSIONS OF WALLS, DOORS, AND WINDOWS UNLESS NOTED OTHERWISE.

C2. REFER TO ARCHITECTURAL DRAWINGS FOR DOOR & WINDOWSCHEDULES, DOOR HARDWARE AND THRESHOLDS UNLESS NOTEDOTHERWISE.

C3. PROVIDE SHOP DRAWINGS OF MILLWORK FOR INTERIOR DESIGNERS'APPROVAL PRIOR TO FABRICATION.

C4. DIMENSIONS TO BE CONFIRMED PRIOR TO CONSTRUCTION OF MILLWORK.CONTRACTOR TO CONFIRM EQUIPMENT SIZES WITH DESIGNER.

C5. ALL WORKMANSHIP AND METHODS OF CONSTRUCTION: SYSTEMS,MATERIAL, PRODUCTS & ASSEMBLIES TO STANDARDS REFERENCED IN VBBL2014 EDITION AND THE HIGHEST STANDARDS CURRENTLY PRACTICED IN THEINDUSTRY.

C6. ALL WORK IS TO COMPLY WITH VANCOUVER BUILDING BY-LAW AND WITHALL REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION.

C7. REFER TO MECHANICAL CONSULTANTS DRAWINGS AND NOTES FOR ALLSPRINKLER, PLUMBING, ETC. WORK.

C8. REFER TO ARCHITECTURAL DRAWINGS FOR REFLECTED CEILING PLANS,UNLESS NOTED OTHERWISE.

C9. REFER TO ELECTRICAL CONSULTANT DRAWINGS FOR ELECTRICAL ANDLIGHTING PLANS UNLESS NOTED OTHERWISE. LIGHTING LOCATIONS TO BECONFIRMED WITH OWNER PRIOR TO ROUGH-IN.

C10. REFER TO ARCHITECTURAL DRAWINGS FOR INTERIOR WALLCONSTRUCTION LEGEND & NOTES.

C11. MANUFACTURER'S INSTALLATION DIRECTIONS (TECHNICAL DATAMANUALS) SHALL BE STRICTLY ADHERED TO IN REGARD TO FINISHES.

C12. ALL SPECIFICATIONS OUTLINED SHALL NOT BE CHANGED WITHOUTAPPROVAL FROM CRISTINA OBERTI INTERIOR DESIGN INC. SHOULD THEGENERAL CONTRACTOR CHANGE ANY FINISHES IN THE SPECIFICATIONS,CRISTINA OBERTI INTERIOR DESIGN INC. IS NOT RESPONSIBLE FOR THESPECIFICATION MATCH UNLESS APPROVED BY CRISTINA OBERTI INTERIORDESIGN INC.

C13. GENERAL CONTRACTOR AND/OR SUBTRADES TO VERIFY ALLDIMENSIONS AND CONDITIONS AS SHOWN ON THIS DRAWING COMPLY WITHACTUAL SITE CONDITIONS. DISCREPANCIES TO BE REPORTED TO CRISTINAOBERTI INTERIOR DESIGN INC. PRIOR TO PROCEEDING WITH CONSTRUCTIONAND INSTALLATIONS.

C14. SUBMIT ALL PAINT DRAWS TO CRISTINA OBERTI INTERIOR DESIGN INC.FOR APPROVAL PRIOR TO ORDERING AND APPLICATION.

FINISHES SCHEDULE

ITEM CONTACTDESCRIPTIONCODE

= WALL FINISH= BASE FINISH = FLOOR FINISH

ITEM CONTACTDESCRIPTIONCODE

FLOOR - TILE

MOUDLING & MILLWORKTEL: 604-882-5500FAX: 604-888-5242

BASEBOARD MANU.: MOULDING & MILLWORKPRODUCT: FLATSTOCKPROFILE: 6" HIGH

PAINT:MANU.: BENJAMIN MOORECOLOR: 2134-30 IRON MOUNTAINPRODUCT: ULTRA SPEC 500, INTERIOR SEMI-GLOSSPRODUCT CODE: K539MPI: QUALIFIES FOR 54 X-GREENFINISH: SEMI-GLOSSGLOSS RANGE: 20-35%FEATURES: ZERO VOC, MPI + LEED APPROVED

BENJAMIN MOOREJODY REPPERTTEL: 604-607-3410

BASE - WOODSTAIN GRADE

SUPPLIER: MOULDING & MILLWORKPRODUCT: 106 POPLARPROFILE: E2E 6" HIGHCOLOR: STAIN TO MATCH "WP1"

MOUDLING & MILLWORKTEL: 604-882-5500FAX: 604-888-5242

SUPPLIER: AEON STONECOLOR: BIANCO PEARLFINISH: POLISHED

WALL -MARBLE SLAB

BENJAMIN MOOREJODY REPPERTTEL: 604-607-3410

MANU.: BENJAMIN MOORECOLOR: OC-152/PM-1 SUPER WHITEPRODUCT: ULTRA SPEC 500, INTERIOR LOW SHEENPRODUCT CODE: K537MPI: QUALIFIES FOR 44 X-GREENFINISH: LOW SHEENGLOSS RANGE: 10-21%FEATURES: ZERO VOC, MPI + LEED APPROVED

BENJAMIN MOOREJODY REPPERTTEL: 604-607-3410

WALL - PAINT

WALL - PAINT

SUPPLIER: TIERRA SOLPRODUCT: PORCELAIN TILESERIES: ANGORA NOTIONCOLOR: MISTCODE: FUANNMIS1836FINISH: NATURAL MATTESIZE: 18"X36"

GROUT: MAPEICOLOR: #107 IRONJOINT: 1/8" THICKNOTE: SPECIAL ORDER 6-8 WEEKS

WALL - WOODVENEER

WALL - TILE SUPPLIER: TIERRA SOLSERIES: CONTRACT WHITE WALL TILECOLOR: WHITECODE: WPNW624MATT-RECTFINISH: MATTESIZE: 6"X24"

GROUT: MAPEICOLOR: #38 AVALANCHEJOINT: 1/8" THICK

FLOOR-CARPET TILE

SUPPLIER: MILLIKENCOLLECTION: NATURALLY DRAWN - AMERICASDESIGN NAME: HAND SKETCHEDCOLOR NAME: HSK173 SPOTTED DOVESIZE: 50CM X 50CMINSTALLATION: ASHLERBACKING SYSTEM: PVC FREE UNDERSCORE ES CUSHIONYARN TYPE: MILLIKEN- CERTIFIED WEARON® NYLON TYPE 6,6TUFTED FACE WEIGHT: 15 OZ/YDCONSTRUCTION: TUFTED, TEXTURED LOOPSOIL/STAIN PROTECTION: STAINSMART®FINISHED PILE HEIGHT: 0.08"

MANU: AMERICAN OLEANSUPPLIER: DAL TILEPRODUCT: AMERICAN OLEAN UNGLAZED CERAMIC MOSAICSSERIES: KEYSTONES GROUPS 1 & 2COLOR: D182 SUEDE GREYDESCRIPTION: 1ROW OF C-833

GROUT: MAPEICOLOR: #107 IRON

BASE - TILE

MANU.: BENJAMIN MOORECOLOR: OC-64 PURE WHITEPRODUCT: ULTRA SPEC 500, INTERIOR LOW SHEENPRODUCT CODE: K537MPI: QUALIFIES FOR 44 X-GREENFINISH: LOW SHEENGLOSS RANGE: 10-21%FEATURES: ZERO VOC, MPI + LEED APPROVED

DALTILEKAREN FOURCHALKTEL: (604) 251-8995

PRODUCT: WOOD VENEER PANELSPECIES: RIFT CUT WHITE OAKFINISH: STAINED TO MATCH KITCHEN CABINET SPECIFICATION SCHEME 2

FLITCH: TO BE ONE FLITCH FOR THE ENTIRE PROJECT.FLITCH SAMPLE TO BE SUBMITTED TO AND APPROVED BYCRISTINA INTERIOR DESIGN INC. PRIOR TO CLOSE OF TENDER.MATCH OF ADJACENT VENEER LEAVES: BOOKMATCHEDMATCHING WITHIN PANEL FACE: CENTER MATCHEFFECT: HALF FILLEDINSTALLATION: HORIZONTAL GRAIN INSTALLATIONWOOD PANELING TO HAVE A FLAME-SPREAD RATING UP TO 150 ATWALLS EXCEPT WITHIN EXITS OR EIXT LOBBIES. WOOD PANELING WITHIN EXITS OR EXIT LOBBIES TO HAVE AFLAME-SPREAD RATING 25 AT WALLS ; 10% OF THE WALL AREAMAY HAVE FSR OF 150NOTE: MILLWORK PRODUCTS MUST BE NAUF (NO ADDED UREAFORMALDEHYDE) NON TROPICAL WOOD MUST BE USED OR FSCCERTIFIED TROPICAL WOOD.

FLOOR -VINYL

MANU: RICHMOND REFLECTIONSSUPPLIER: DIVISION 9PRODUCT: VINYL FLOORINGSERIES: FIRMFITCOLOR: SURFSIDECODE: RVI0026FIRMFITSIZE: PLANK 5.67" X 47.75"

WALL - VINYLWALLCOVERING

SUPPLIER: METRO WALLCOVERINGSMANU.: PATTY MADDENSERIES: CHEVALCOLOR: LXB-CHL-17 TOUCH OF PEARLINSTALLATION: RANDOM REVERSEWIDTH: 54"/55" TYPE IIBACKING: NON WOVEN

TIERRA SOLSAL CHIRICOCEL: 604-970-5475

SUPPLIER: TIERRA SOLPRODUCT: PORCELAIN TILESERIES: ANGORA NOTIONCOLOR: MISTCODE: FUANNMIS1224FINISH: NATURAL MATTESIZE: 12"X24"

GROUT: MAPEICOLOR: #107 IRONJOINT: 1/8" THICK

TIERRA SOLSAL CHIRICOCEL: 604-970-5475

FLOOR - TILE

MILLIKENMIKE PAJIC604-808-6614

TIERRA SOLSAL CHIRICOCEL: 604-970-5475

AEON STONE + TILE INCCOLBY HENNESSYCEL: 604-710-2298

WALL - TILE SUPPLIER: OLYMPIA TILESERIES: CARRARA XCOLOR: WHITECODE: OV.CX.WHT.2448.PLFINISH: POLISHEDSIZE: 24"X48"

GROUT: MAPEICOLOR: #77 FROSTJOINT: 1/8" THICK

OLYMPIA TILEPAULA NICKERSONCEL: 604-765-2799

METROWALLCOVERINGSKRISTY WOODSTEL: 604-736-9756

DIVISION9AL HURLEYTEL: 604-636-3565CEL: 604-341-5409

NOV. 29 2018 ISSUED FOR IDSI #3

Page 5: SITE INSTRUCTION SI -35-R1 · Mechanical Engineer Richard Corra 604 888 7779 richard.corra@rpeng.ca Electrical Engineer Blake Shine 604 475 6725 blake@opaleng.com Landscape Architect

SHEET TITLE:

CHECKED BY:

SCALE:

DATE:

DRAWN BY:

SK-9

NO.

JF

NOTE: This drawing is an instrument of service andmust only be used in conjunction with the ProjectManual and all other drawings, specifications,correspondence and information pertinent to the project.The Contractor shall verify references, datum anddimensions on site and request clarification, fromCristina Oberti Interior Design Inc., of any discrepanciesor omissions as soon as they are discovered prior toexecution of any work. The Contractor is responsible forthe method of execution and for compliance of all workswith the requirements of the Authorities HavingJurisdiction. Written architectural dimensions takeprecedence in the coordination of information. Do notscale drawings.

CO

DATE ISSUE / REVISION

CRISTINA OBERTI INTERIOR DESIGN INC.

PROJECT NO: 2016-11

PROJECT TITLE:

INTERIOR DESIGNER:

CO

Copyright: This drawing, including the designconcepts, is an instrument of service and exclusiveproperty of Cristina Oberti Interior Design Inc.It cannot be used or reproduced without knowledgeand expressed consent of Cristina Oberti InteriorDesign Inc.

1460-1188 WEST GEORGIA ST.VANCOUVER, BC V6E 4A2

HAWTHORNE4976-5010 CAMBIE STREETVANCOUVER, BC, CANADA

COMMON AREALOBBY ELEVATIONS

SEPTEMBER 2016

Tel. 604.697.0363Fax [email protected]

1/2" = 1'-0"

NOV. 18 2016 ISSUED FOR 50% PROGRESS

DEC. 21 2016 ISSUED FOR 65% PROGRESS

FEB. 3 2017 ISSUED FOR CLIENTS REVIEW

FEB. 17 2017 ISSUED FOR 75% PROGRESS

JUNE 30 2017 ISSUED FOR TENDER

JULY 31 2017 ISSUED FOR TENDER/BP SET

JULY 4 2018 ISSUED FOR CONSTRUCTION

3 BAY PANEL 3 BAY PANEL 3 BAY PANEL

WP1 WP1

S1

WP1 WP1

B2 B2

B2

4ID-3

6ID-3

V1

B2

7ID-3

5ID-3

S1 WP1WP1

WP1

B2B2 B2

WP1

B2

WP1

S1

3ID-3

B2

WP1 WP1 WP1 WP1

1ID-3

B2

B2 B2

WP1

WP1

2ID-3

WP1

B2

WP1

WP1

WP1

B2

WP1

WP1

1'-9 1/2" 6" 3'-10 1/4" 6" 1'-7 1/4"8'-2 7/8"

6"1/

2"E

Q1/

2"E

Q1/

2"E

Q1/

2"7'

-8"

7'-7/8" 1/2" EQ 1/2" EQ 1/2"14'-9 7/8"

6"1/

2"E

Q1/

2"E

Q1/

2"E

Q1/

2"7'

-8"

1" 2' 3'-1 7/8" 1" 2' 1"7'-4 7/8"

9'4"

2'-6

3/4

"1

1/4"

1'-1

0"4'

-1"

1"

6"

EQ EQ EQ EQ

1/2" 5'-9 3/4" 1/2"5'-10 3/4" 5'-10" 7'-6 7/8" 4'-10 1/4"

1/2" EQ 1/2" EQ 1/2" 2 1/2" 3'-4 1/4" 1'-3 1/2"6"1/

2"E

Q1/

2"E

Q1/

2"E

Q1/

2"7'

-8"

4'-1 1/2" 4 1/2" 9'-2" 1/2" 4'-4 3/4" 1/2"23'-2"

6"1/

2"E

Q1/

2"E

Q1/

2"2'

-3 7

/8"

1/2"

7'-8

"

1'-3

"3"

1 1/

2"1'

1'-6

"

EQ EQ

10'

6"1/

2"E

Q1/

2"E

Q1/

2"E

Q1/

2"7'

-8"

13'-7 3/4"1/2" EQ 1/2" EQ 1/2" 4'-10 1/2" 1/2" 1/2" 3'-11 1/4" 1/2" 1/2" 5' 1/2"

10'

3'-3 1/2" 7'-3" 7'-10 7/8"18'-5 3/8"

6"1/

2"1'

-8 1

/4"

1/2"

EQ

1/2"

EQ

1/2"

EQ

1/2"

6 1/

2"1/

2"10

'

1/2" EQ 1/2" EQ 1/2"

LINE OF WALL."WP1" TO WRAP AROUND

QUARTZCOUNTERTOP

TYP. SEAM LINE.

LINE OF WALL LINE OF WALL

QUARTZSLAB BACKSPLASH

1/2" REVEALSTAINED TOMATCH "WP1" TYP.

1/2" REVEALSTAINED TOMATCH "WP1" TYP.

1/2" REVEALSTAINED TO

MATCH "WP1" TYP.

1 1/4" QUARTZ WITH 3" HIGHFRONT FACE

SUPPLIER: CAESARSTONECOLOR: 1141 PURE WHITEPROFILE: SQUARE EDGED

TYP. 1/2" THICK x 1 1/2" WIDESTAIN GRADE FLAT STOCK

FINISH TO MATCH "WP1"

TYP. SEAM LINE.

LINE OF WALL

HANDRAIL AND STAIR DETAILBY ARCHITECT

1/2" REVEALSTAINED TOMATCH "WP1" TYP.

ALIGN

LINE OF WALL."S1" TO WRAP AROUND

MANU.: CANADIAN MAILBOX MAILBOXES COMPANYSERIES: HORIZONTAL MAILBOXESINTERIOR MODEL: 1230 F/L (FRONT LOADING)QUANTITY: 1 OF 6 HIGH X 5 WIDE & 1 OF 6 HIGH X 6 WIDENUMBER OF MAILBOXES: 46 REGULAR (A) + 4 PARCELBOXES + 1 BV BOX*ONE COMPARTMENT IN EACH IS ALLOCATED FORMASTER LOCK

RECYCLESLOT

ALL EXPOSED MILLWORK TOBE STAINED TP MATCH "WP1"

ALIGN ALIGN

ADJ. SHELF TYP.

"F1" FINSHSIDE OF STAIRS

INSTALL SCHLUTERTREP-G-B ON TILE

STAIRS

1/2" REVEALSTAINED TO

MATCH "WP1" TYP.

LINE OF WALLWP1 TO WRAP

AROUND

ALIGN REVEALSTYP.

HANDRAIL AND STAIR DETAILBY ARCHITECT

1/2" REVEALSTAINED TOMATCH "WP1" TYP.

INSTALL SCHLUTERTREP-G-B ON TILESTAIRS

"F1" FINSHSIDE OF STAIRS

LINE OF WALL

ALIGN

1/2" REVEALSTAINED TOMATCH "WP1" TYP.

LINE OF WALL

ELEVATOR CAB DOOR ANDDOOR FRAME TO BE

STAINLESS STEEL

LOBBY ELEVATIONSCALE: 1/2" = 1'-0"

LOBBY ELEVATIONSCALE: 1/2" = 1'-0"

24" FULLY INTEGRATEDDISHWWASHER

FIXED PANEL

SCALE: 1/2" = 1'-0"AMENITY KITCHEN ELEVATION

REFER TO ARCHITECTURALDRAWINGS FOR DOOR SCHEDULE

& LOCATION

LOBBY ELEVATIONSCALE: 1/2" = 1'-0"

REFER TO ARCHITECTURALDRAWINGS FOR DOOR SCHEDULE

& LOCATION

REFER TO ARCHITECTURALDRAWINGS FOR DOOR SCHEDULE

& LOCATION

NOTE: FINISHES TO BE AS PER ID SCHEME 2.PLUMBING SPECIFICATIONS AS PER INTERIOR SUITES.APPLIANCE SPECIFICATIONS BY OTHERS.

24" U/C FRIDGE

LOBBY ELEVATIONSCALE: 1/2" = 1'-0"

BULLETIN BOARDBEHIND

LOCKABLE GLASS

REFER TO ARCHITECTURALDRAWINGS FOR DOOR SCHEDULE

& LOCATION MASTER MASTER

REFER TO ARCHITECTURALDRAWINGS FOR DOOR/WINDOW

SCHEDULE & LOCATION

LOBBY ELEVATIONSCALE: 1/2" = 1'-0"

LOBBY ELEVATIONSCALE: 1/2" = 1'-0"

REFER TO ARCHITECTURALDRAWINGS FOR DOOR SCHEDULE

& LOCATION

D5ID-11

D6ID-11

D7ID-11

WP1

S1

B2

S1ID-11

S2ID-11

D4ID-11

B2

D2ID-11

D1ID-11

D3ID-11

D3ID-11

B2

WP1

S1

V1

3

3

GENERAL NOTESC1. REFER TO ARCHITECTURAL DRAWINGS FOR ALL LOCATIONS AND DIMENSIONS OFWALLS, DOORS, AND WINDOWS UNLESS NOTED OTHERWISE.

C2. REFER TO ARCHITECTURAL DRAWINGS FOR DOOR & WINDOW SCHEDULES, DOORHARDWARE AND THRESHOLDS UNLESS NOTED OTHERWISE.

C3. PROVIDE SHOP DRAWINGS OF MILLWORK FOR CRISTINA OBERTI INTERIOR DESIGNINC.'S APPROVAL PRIOR TO FABRICATION.

C4. DIMENSIONS TO BE CONFIRMED PRIOR TO CONSTRUCTION OF MILLWORK.CONTRACTOR TO CONFIRM EQUIPMENT SIZES WITH CRISTINA OBERTI INTERIORDESIGN INC.

C5. ALL WORKMANSHIP AND METHODS OF CONSTRUCTION; SYSTEMS, MATERIAL,PRODUCTS & ASSEMBLIES TO STANDARDS REFERENCED IN VBBL 2014 EDITION ANDTHE HIGHEST STANDARDS CURRENTLY PRACTICED IN THE INDUSTRY.

C6. ALL WORK IS TO COMPLY WITH CURRENT CITY BUILDING BY-LAW AND WITH ALLREQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION.

C7. REFER TO MECHANICAL CONSULTANTS DRAWINGS AND NOTES FOR ALLSPRINKLER, PLUMBING, ETC. WORK.

C8. REFER TO ARCHITECTURAL DRAWINGS FOR REFLECTED CEILING PLANS, UNLESSNOTED OTHERWISE.

C9. REFER TO ELECTRICAL CONSULTANT DRAWINGS FOR ELECTRICAL AND LIGHTINGPLANS UNLESS NOTED OTHERWISE. LIGHTING LOCATIONS TO BE CONFIRMED WITHOWNER PRIOR TO ROUGH-IN.

C10. REFER TO ARCHITECTURAL DRAWINGS FOR INTERIOR WALL CONSTRUCTIONLEGEND & NOTES.

C11. MANUFACTURER'S INSTALLATION DIRECTIONS (TECHNICAL DATA MANUALS) SHALLBE STRICTLY ADHERED TO IN REGARD TO FINISHES.

C12. ALL SPECIFICATIONS OUTLINED SHALL NOT BE CHANGED WITHOUT APPROVALFROM CRISTINA OBERTI INTERIOR DESIGN INC. SHOULD THE GENERAL CONTRACTORCHANGE ANY FINISHES IN THE SPECIFICATIONS, CRISTINA OBERTI INTERIOR DESIGNINC. IS NOT RESPONSIBLE FOR THE SPECIFICATION MATCH UNLESS APPROVED BYCRISTINA OBERTI INTERIOR DESIGN INC.

C13. GENERAL CONTRACTOR AND/OR SUBTRADES TO VERIFY ALL DIMENSIONS ANDCONDITIONS AS SHOWN ON THIS DRAWING COMPLY WITH ACTUAL SITE CONDITIONS.DISCREPANCIES TO BE REPORTED TO CRISTINA OBERTI INTERIOR DESIGN INC. PRIORTO PROCEEDING WITH CONSTRUCTION AND INSTALLATIONS.

C14. SUBMIT ALL PAINT DRAWS TO CRISTINA OBERTI INTERIOR DESIGN INC. FORAPPROVAL PRIOR TO ORDERING AND APPLICATION.

FINISHES SCHEDULE

ITEM CONTACTDESCRIPTIONCODE

= WALL FINISH= BASE FINISH = FLOOR FINISH

BASE - WOODSTAIN GRADE

SUPPLIER: MOULDING & MILLWORKPRODUCT: 106 POPLARPROFILE: E2E 6" HIGHCOLOR: STAIN TO MATCH "WP1"

MOUDLING & MILLWORKTEL: 604-882-5500FAX: 604-888-5242

WALL - WOODVENEER

WALL -MARBLE SLAB

PEBO STONETED TRANTEL: (604) 322-9188

WALL - VINYLWALLCOVERING

SUPPLIER: AEON STONECOLOR: BIANCO PEARLFINISH: POLISHED

PRODUCT: WOOD VENEER PANELSPECIES: RIFT CUT WHITE OAKFINISH: STAINED TO MATCH KITCHEN CABINET SPECIFICATION SCHEME 2

FLITCH: TO BE ONE FLITCH FOR THE ENTIRE PROJECT.FLITCH SAMPLE TO BE SUBMITTED TO AND APPROVED BYCRISTINA INTERIOR DESIGN INC. PRIOR TO CLOSE OF TENDER.MATCH OF ADJACENT VENEER LEAVES: BOOKMATCHEDMATCHING WITHIN PANEL FACE: CENTER MATCHEFFECT: HALF FILLEDINSTALLATION: HORIZONTAL GRAIN INSTALLATIONWOOD PANELING TO HAVE A FLAME-SPREAD RATING UP TO 150 ATWALLS EXCEPT WITHIN EXITS OR EIXT LOBBIES. WOOD PANELING WITHIN EXITS OR EXIT LOBBIES TO HAVE AFLAME-SPREAD RATING 25 AT WALLS ; 10% OF THE WALL AREAMAY HAVE FSR OF 150NOTE: MILLWORK PRODUCTS MUST BE NAUF (NO ADDED UREAFORMALDEHYDE) NON TROPICAL WOOD MUST BE USED OR FSCCERTIFIED TROPICAL WOOD.

SUPPLIER: METRO WALLCOVERINGSMANU.: PATTY MADDENSERIES: CHEVALCOLOR: LXB-CHL-17 TOUCH OF PEARLINSTALLATION: RANDOM REVERSEWIDTH: 54"/55" TYPE IIBACKING: NON WOVEN

METROWALLCOVERINGSKRISTY WOODSTEL: 604-736-9756

NOV. 29 2018 ISSUED FOR IDSI #3

MILLWORK /FINISHES NOTES1. PROVIDE PROPER BACKING TOALL WALL PANELS FOR SUPPORT. ie.PLYWOOD.

2. MITRE ALL EXPOSED CORNERS,GLUE ALL CONNECTIONS.

3. CONTRACTOR TO SUPPLYSUPPORT BLOCKING TO SUIT.

4. CONTRACTOR TO CONFIRMDIMENSIONS OF ALL EQUIPMENTAND FIXTURES WITH CLIENT ANDCRISTINA OBERTI INTERIOR DESIGNINC. PRIOR TO PROCEEDING.PROVIDE FILLER STRIPS ADJACENTTO ALL EQUIPMENT.

5. ALL MILLWORK SHALL BEMANUFACTURERED AND/ORINSTALLED AS PER AWMAC QUALITYSTANDARDS SPECIFICATIONSMANUAL.

6. SUBMIT SHOP DRAWINGS FORREVIEW FOR ALL MILLWORK PRIORTO FABRICATION.

7. MILLWORK SPECIFIED FORSTAINING TO BE SHOP APPLIED.SUBMIT SAMPLE FOR CRISTINAOBERTI INTERIOR DESIGN INC.'SAPPROVAL.

8. MILLWORK PRODUCTS MUST BENAUF (NO ADDED UREAFORMALDEHYDE) NON TROPICALWOOD MUST BE USED OR FSCCERTIFIED TROPICAL WOOD.

Page 6: SITE INSTRUCTION SI -35-R1 · Mechanical Engineer Richard Corra 604 888 7779 richard.corra@rpeng.ca Electrical Engineer Blake Shine 604 475 6725 blake@opaleng.com Landscape Architect

SHEET TITLE:

CHECKED BY:

SCALE:

DATE:

DRAWN BY:

SK-10

NO.

JF

NOTE: This drawing is an instrument of service andmust only be used in conjunction with the ProjectManual and all other drawings, specifications,correspondence and information pertinent to the project.The Contractor shall verify references, datum anddimensions on site and request clarification, fromCristina Oberti Interior Design Inc., of any discrepanciesor omissions as soon as they are discovered prior toexecution of any work. The Contractor is responsible forthe method of execution and for compliance of all workswith the requirements of the Authorities HavingJurisdiction. Written architectural dimensions takeprecedence in the coordination of information. Do notscale drawings.

CO

DATE ISSUE / REVISION

CRISTINA OBERTI INTERIOR DESIGN INC.

PROJECT NO: 2016-11

PROJECT TITLE:

INTERIOR DESIGNER:

CO

Copyright: This drawing, including the designconcepts, is an instrument of service and exclusiveproperty of Cristina Oberti Interior Design Inc.It cannot be used or reproduced without knowledgeand expressed consent of Cristina Oberti InteriorDesign Inc.

1460-1188 WEST GEORGIA ST.VANCOUVER, BC V6E 4A2

HAWTHORNE4976-5010 CAMBIE STREETVANCOUVER, BC, CANADA

COMMON AREAAMENITY ROOM, SUITE

ENTRY ELEVATIONS ANDELEVATOR CAB PLAN

AND ELEVATIONS

SEPTEMBER 2016

Tel. 604.697.0363Fax [email protected]

1/2" = 1'-0"

NOV. 18 2016 ISSUED FOR 50% PROGRESS

DEC. 21 2016 ISSUED FOR 65% PROGRESS

FEB. 3 2017 ISSUED FOR CLIENTS REVIEW

FEB. 17 2017 ISSUED FOR 75% PROGRESS

JUNE 30 2017 ISSUED FOR TENDER

JULY 31 2017 ISSUED FOR TENDER/BP SET

JULY 4 2018 ISSUED FOR CONSTRUCTION

13ID-10

11ID-10

12ID-10

14

18ID-7

WP1

WP1

B2

B2 B2

S1

S1

B2 B2

15

B1

P1

WP1

12ID-10

WP2

13ID-10

12SIMID-10

11ID-10 F2

B4

16ID-7

WP1

B2

WP1

S1

B2

19ID-7

S1

B2 B2

17ID-7

WP1

S1

B2 B2

21ID-7

20ID-7

WP1

B2

WP1

B2

WP1

B2

WP1WP1

S1

T1

P1

T1

P1

T2

10ID-3

8ID-3

9ID-3

T1

P1

10AID-3

TO S

UIT

1'

3" TO SUIT 3"

6" TO SUIT 6"6" 4'-10" 6"

4"2'

-4 1

/4"

3"1

1/2"

3"TO

SU

IT3"

4"3"

2'-1

1/4

"3"1

1/2"

3"TO

SU

IT3"

TO S

UIT

1'3" 5'-4" 3"

1/2" EQ 1/2" EQ 1/2"10'-5"

6"1/

2"E

Q1/

2"E

Q1/

2"E

Q1/

2"7'

-8"

1/2" 5'-5 1/2" 1/2"9'-10 1/2"

6"1/

2"E

Q1/

2"E

Q1/

2"E

Q1/

2"8'

-6"

1/2" 10 7/8" 1/2"

10 3/8" 3'-10 1/4" TO SUIT16'-2 1/4"

7'-8

"

5'3'

-6 3

/8"

5'-10"

1/2" EQ 1/2" EQ 1/2"10'-5"

6"1/

2"E

Q1/

2"E

Q1/

2"E

Q1/

2"8'

3'-9 3/4" 10 3/8" 3'-10 1/4" 10 3/8"

8'-6

"

9'-5"9'-9 5/8" 10 3/8" 3'-10 1/4" 10 3/8" 3'-1 3/4" 10 3/8" 3'-10 1/4" 10 3/8"

9'-7

"

1/2" EQ 1/2" EQ 1/2"7'-5 1/2"

6"1/

2"E

Q1/

2"E

Q1/

2"E

Q1/

2"E

Q1/

2"9'

-7"

8'

3'

7'-8

"

2'-5

1/4

"3

1/2"

1 1/

4"3

1/2"

1'-2" 7"

1'1'

-2 1

/4"

6 1/

2"1

1/4"

2'-1

0"3

1/2"

1 1/

2"3'

-2"

1'-3

"

2'-5 1/2" 3'-4" 1'-6"7'-3 1/2"

9" 2' 2' 2'6'-9"

8 1/2" 2' 9"6'-9"

2"6"

6"6"

6"6"

6"6"

6"4'

-2"

3'-6

"

2"6"

6"6"

6"6"

6"6"

6"

3'-3

"

EQ EQ

2"2'

2'2'

1'-6

"

4'-2

"3'

-6"

2'2'2'1'-3 1/2"2"6"

6"6"

6"6"

6"6"

6"4'

-2"

3'-6

"

7'-3 1/2"

RE

FER

TO

NO

TE F

OR

MO

UN

TIN

G H

EIG

HT

7'-8

"

7'-8

"

7'-8

"

TYP. BRUSHEDSTAINLESS STEEL

TYP. BRUSHEDSTAINLESS STEEL

MIN. PLENUM FORRECESSED LIGHT

FIXTURES

TYP. 1 1/2" DIAM.BRUSHED STAINLESSSTEEL HANDRAIL C/W

FLAT HAMMER ONEND CAPS EXCEPT

WHERE NOTED.HANDRAIL S/B 1 3/4"CLEAR OF FINISHEDWALL MOUNTED AT36" A.F.F. O.C. TYP.

MIN. PLENUM FORRECESSED LIGHTFIXTURES

TYP. BRUSHEDSTAINLESS STEEL

TYP. BRUSHEDSTAINLESS STEEL

TYP. CLEAR LAMINATEDMIRROR. PROVIDE SAMPLESTO CLIENT & CRISTINAOBERTI INTERIOR DESIGNINC. FOR APPROVAL PRIOR TOINSTALLATION.

TYP. 1 1/2" DIAM. BRUSHEDSTAINLESS STEEL HANDRAILC/W FLAT HAMMER ON ENDCAPS EXCEPT WHERE NOTED.HANDRAIL S/B 1 3/4" CLEAR OFFINISHED WALL MOUNTED AT36" A.F.F. O.C. TYP.

FRAME & PANELASSEMBLY -TYPICALNOTE: STANDARD LAMINATEFACED STILE, RAIL, AND PANEL.LAMINATE "WP2", FIRE RATEDHORIZONTAL GRAIN DIRECTION

TYP. BRUSHEDSTAINLESS STEEL

MIN. PLENUM FORRECESSED LIGHTFIXTURES

TYP. BRUSHEDSTAINLESS STEEL

TYP. BRUSHEDSTAINLESS STEEL

TYP. CLEAR LAMINATEDMIRROR. PROVIDESAMPLES TO CLIENT &CRISTINA OBERTIINTERIOR DESIGN INC.FOR APPROVAL PRIORTO INSTALLATION.

TYP. 1 1/2" DIAM. BRUSHEDSTAINLESS STEEL HANDRAILC/W FLAT HAMMER ON ENDCAPS EXCEPT WHERE NOTED.HANDRAIL S/B 1 3/4" CLEAR OFFINISHED WALL MOUNTED AT36" A.F.F. O.C. TYP.

FRAME & PANELASSEMBLY -TYPICALNOTE: STANDARD LAMINATEFACED STILE, RAIL, AND PANEL.LAMINATE "WP2", FIRE RATEDHORIZONTAL GRAIN DIRECTION

SIGNAGE BY OTHERS

WOOD GRAIN

BUTT JOINT WITH1/8" BEVEL EDGE

1/2" x 2 1/2" PAINTED MDF FLAT STOCK JAMB CASINGPAINTED WITH -MANU.: BENJAMIN MOORECOLOR: 2134-30 IRON MOUNTAINPRODUCT: ULTRA SPEC 500, INTERIOR SEMI-GLOSSPRODUCT CODE: K539MPI: QUALIFIES FOR 54 X-GREENFINISH: SEMI-GLOSSGLOSS RANGE: 20-35%FEATURES: ZERO VOC, MPI + LEED APPROVED

PEEPHOLE BYOTHERS

ALIGN SEAM LINESWITH REVEALS, TYP.

ALIGN SEAM LINESWITH REVEALS, TYP.

ALIGN SEAM LINESWITH REVEALS, TYP.

1/2" REVEALSTAINED TOMATCH "WP1" TYP.

1/2" REVEALSTAINED TOMATCH "WP1" TYP.

SEAMS TO ALIGNWITH MILLWORK

REVEALS ONOPPOSITE WALL

1/2" REVEAL STAINED TOMATCH "WP1" TYP.

1/2" REVEAL STAINED TOMATCH "WP1" TYP.

1/2" REVEAL STAINED TOMATCH "WP1" TYP.

1/2" REVEAL STAINED TOMATCH "WP1" TYP.

LINE OF WALL.P1 TO WRAP

AROUND

LINE OF WALL.WP1 TO WRAP

AROUND

LINE OF WALL.WP1 TO WRAP AROUND

LINE OF WALL.WP1 TO WRAP AROUND

REFER TO FLOOR PLAN FORDIMENSIONS TO SUIT

MIRROR FRAME TO BESTAINED TO MATCH "WP1"

FRAMELESS MIRRORWITH POLISHEDEDGES

LAMINATE SKIRT "WP2"

QUARTZ COUNTERTOP,BACKSPLASH & SKIRTSUPPLIER: CAESARSTONECOLOR: 1141 PURE WHITEPOLISHEDPROFILE: SQUARE EDGEDTHICKNESS: 3/4"

GRAB BAR BYOTHERS

PROVIDESOAP

DISPENSER

INSTALL ALUMINUMSCHLUTER EDGE TO

MATCH TILETHICKNESS

QUARTZ COUNTERTOP,BACKSPLASH & SKIRT

SUPPLIER: CAESARSTONECOLOR: 1141 PURE WHITEPROFILE: SQUARE EDGED

POLISHEDTHICKNESS: 3/4"

INSTALL ALUMINUMSCHLUTER EDGE TO MATCHTILE THICKNESS

ALIGN

INSTALL ALUMINUMSCHLUTER EDGE TOMATCH TILE THICKNESS

GRAB BAR BYOTHERS

TYP. TOILET TISSUEDISPENSERMANU.: BOBRICKPRODUCT NO.: B-4288

TYP. SANITARYNAPKIN DISPOSALMANU.: BOBRICKPRODUCT NO.: B-270

SCALE: 1/2" = 1'-0"ELEVATOR CAB ELEVATION

ELEVATOR CAB DOORAND FRAME IN LOBBY

TO BE STAINLESS STEEL

CAB DOOR OPENINGVARIES

SCALE: 1/2" = 1'-0"ELEVATOR CAB ELEVATION

SCALE: 1/2" = 1'-0"ELEVATOR CAB ELEVATION

SCALE: 1/2" = 1'-0"ELEVATOR CAB FLOOR PLAN

REFER TO ARCHITECTURALDRAWINGS FOR DOOR

SCHEDULE & LOCATION

SCALE: 1/2" = 1'-0"ELEVATOR LOBBY LEVEL 2-5 ELEVATION

SCALE: 1/2" = 1'-0"

ELEVATOR CAB DOOR

SCALE: 1/2" = 1'-0"

TYPICAL SUITE ENTRYDOOR TO BE STAINED TO

MATCH WP1

101

ELEVATOR LOBBY LEVEL 7 ELEVATION

ELEVATOR LOBBY LEVEL 2-5 ELEVATIONSCALE: 1/2" = 1'-0"ELEVATOR LOBBY LEVEL 6 ELEVATION

ELEVATOR CAB DOOR

SCALE: 1/2" = 1'-0"ELEVATOR LOBBY LEVEL 7 ELEVATION

ELEVATOR CAB DOOR

SCALE: 1/2" = 1'-0"ELEVATOR LOBBY LEVEL 6 ELEVATION

ELEVATOR CAB DOOR

SCALE: 1/2" = 1'-0"ELEVATOR LOBBY ELEVATION

SCALE: 1/2" = 1'-0"ELEVATOR LOBBY ELEVATION

SCALE: 1/2" = 1'-0"AMENITY WASHROOM ELEVATION

SCALE: 1/2" = 1'-0"AMENITY WASHROOM ELEVATION

SCALE: 1/2" = 1'-0"AMENITY WASHROOM ELEVATION

SCALE: 1/2" = 1'-0"AMENITY WASHROOM ELEVATION

NOTE: PLUMBING SPECIFICATIONS BY OTHERS. NOTE: PLUMBING SPECIFICATIONS BY OTHERS.

REFER TO ARCHITECTURALDRAWINGS FOR DOOR SCHEDULE

& LOCATION

WP2 WP2 WP2WP2

B4 B4B4

S1 S1S1S1 S1

S1

B3B3 B3 B3

11/16" x 3 1/2" PAINTED MDF HEAD CASING

MANU.: BENJAMIN MOORECOLOR: 2134-30 IRON MOUNTAINPRODUCT: ULTRA SPEC 500, INTERIOR SEMI-GLOSSPRODUCT CODE: K539MPI: QUALIFIES FOR 54 X-GREENFINISH: SEMI-GLOSSGLOSS RANGE: 20-35%FEATURES: ZERO VOC, MPI + LEED APPROVED

HAND DRYERMANU.: BOBRICKPRODUCT NO.: B-750 848STYLE: BARRIERFREE COMPLIANTAIRCRAFT HAND DRYER

NOTE: HAND DRYER TO BEMOUNTED 48" FROM FLOORTO BOTTOM SCREW HOLEOF MOUNTING BASE

WP1

B1

B2

B3

F2

T1

P1

WP2

B4

T2

S1

3

3

GENERAL NOTESC1. REFER TO ARCHITECTURALDRAWINGS FOR ALL LOCATIONS ANDDIMENSIONS OF WALLS, DOORS, ANDWINDOWS UNLESS NOTED OTHERWISE.

C2. REFER TO ARCHITECTURALDRAWINGS FOR DOOR & WINDOWSCHEDULES, DOOR HARDWARE ANDTHRESHOLDS UNLESS NOTEDOTHERWISE.

C3. PROVIDE SHOP DRAWINGS OFMILLWORK FOR CRISTINA OBERTIINTERIOR DESIGN INC.'S APPROVAL PRIORTO FABRICATION.

C4. DIMENSIONS TO BE CONFIRMEDPRIOR TO CONSTRUCTION OF MILLWORK.CONTRACTOR TO CONFIRM EQUIPMENTSIZES WITH CRISTINA OBERTI INTERIORDESIGN INC.

C5. ALL WORKMANSHIP AND METHODS OFCONSTRUCTION; SYSTEMS, MATERIAL,PRODUCTS & ASSEMBLIES TO STANDARDSREFERENCED IN VBBL 2014 EDITION ANDTHE HIGHEST STANDARDS CURRENTLYPRACTICED IN THE INDUSTRY.

C6. ALL WORK IS TO COMPLY WITHCURRENT CITY BUILDING BY-LAW ANDWITH ALL REQUIREMENTS OF THEAUTHORITIES HAVING JURISDICTION.

C7. REFER TO MECHANICALCONSULTANTS DRAWINGS AND NOTESFOR ALL SPRINKLER, PLUMBING, ETC.WORK.

C8. REFER TO ARCHITECTURALDRAWINGS FOR REFLECTED CEILINGPLANS, UNLESS NOTED OTHERWISE.

C9. REFER TO ELECTRICAL CONSULTANTDRAWINGS FOR ELECTRICAL ANDLIGHTING PLANS UNLESS NOTEDOTHERWISE. LIGHTING LOCATIONS TO BECONFIRMED WITH OWNER PRIOR TOROUGH-IN.

C10. REFER TO ARCHITECTURALDRAWINGS FOR INTERIOR WALLCONSTRUCTION LEGEND & NOTES.

C11. MANUFACTURER'S INSTALLATIONDIRECTIONS (TECHNICAL DATA MANUALS)SHALL BE STRICTLY ADHERED TO INREGARD TO FINISHES.

C12. ALL SPECIFICATIONS OUTLINEDSHALL NOT BE CHANGED WITHOUTAPPROVAL FROM CRISTINA OBERTIINTERIOR DESIGN INC. SHOULD THEGENERAL CONTRACTOR CHANGE ANYFINISHES IN THE SPECIFICATIONS,CRISTINA OBERTI INTERIOR DESIGN INC. ISNOT RESPONSIBLE FOR THESPECIFICATION MATCH UNLESSAPPROVED BY CRISTINA OBERTI INTERIORDESIGN INC.

C13. GENERAL CONTRACTOR AND/ORSUBTRADES TO VERIFY ALL DIMENSIONSAND CONDITIONS AS SHOWN ON THISDRAWING COMPLY WITH ACTUAL SITECONDITIONS. DISCREPANCIES TO BEREPORTED TO CRISTINA OBERTI INTERIORDESIGN INC. PRIOR TO PROCEEDING WITHCONSTRUCTION AND INSTALLATIONS.

C14. SUBMIT ALL PAINT DRAWS TOCRISTINA OBERTI INTERIOR DESIGN INC.FOR APPROVAL PRIOR TO ORDERING ANDAPPLICATION.

FINISHES SCHEDULE

ITEM CONTACTDESCRIPTIONCODE

= WALL FINISH= BASE FINISH = FLOOR FINISH

WALL - WOODVENEER

MOUDLING & MILLWORKTEL: 604-882-5500FAX: 604-888-5242

BASEBOARD

BENJAMIN MOOREJODY REPPERTTEL: 604-607-3410

BASE - WOODSTAIN GRADE

MOUDLING & MILLWORKTEL: 604-882-5500FAX: 604-888-5242

BASE - TILE DALTILEKAREN FOURCHALKTEL: (604) 251-8995

FLOOR - TILE

PRODUCT: PLASTIC LAMINATEMANU.: WILSONARTCOLOR: NATURAL RECONCOLOR NUMBER: 7996FINISH: 60 MATTE FIRE RATED

WALL - PLASTICLAMINATE

WALL - TILE

BENJAMIN MOOREJODY REPPERTTEL: 604-607-3410

WALL - PAINT

BASE - TILE

MANU: AMERICAN OLEANSUPPLIER: DAL TILEPRODUCT: AMERICAN OLEAN UNGLAZED CERAMIC MOSAICSSERIES: KEYSTONES GROUPS 1 & 2COLOR: D182 SUEDE GREYDESCRIPTION: 1ROW OF C-833

GROUT: MAPEICOLOR: #107 IRON

SUPPLIER: MOULDING & MILLWORKPRODUCT: 106 POPLARPROFILE: E2E 6" HIGHCOLOR: STAIN TO MATCH "WP1"

MANU.: MOULDING & MILLWORKPRODUCT: FLATSTOCKPROFILE: 6" HIGH

PAINT:MANU.: BENJAMIN MOORECOLOR: 2134-30 IRON MOUNTAINPRODUCT: ULTRA SPEC 500, INTERIOR SEMI-GLOSSPRODUCT CODE: K539MPI: QUALIFIES FOR 54 X-GREENFINISH: SEMI-GLOSSGLOSS RANGE: 20-35%FEATURES: ZERO VOC, MPI + LEED APPROVED

SUPPLIER: TIERRA SOLPRODUCT: PORCELAIN TILESERIES: ANGORA NOTIONCOLOR: MISTCODE: FUANNMIS1224FINISH: NATURAL MATTESIZE: 12"X24" CUT DOWN TO 6"X24"

GROUT: MAPEICOLOR: #107 IRONJOINT: 1/8" THICK

TIERRA SOLSAL CHIRICOCEL: 604-970-5475

SUPPLIER: TIERRA SOLPRODUCT: PORCELAIN TILESERIES: ANGORA NOTIONCOLOR: MISTCODE: FUANNMIS1224FINISH: NATURAL MATTESIZE: 12"X24"

GROUT: MAPEICOLOR: #107 IRONJOINT: 1/8" THICK

TIERRA SOLSAL CHIRICOCEL: 604-970-5475

PRODUCT: WOOD VENEER PANELSPECIES: RIFT CUT WHITE OAKFINISH: STAINED TO MATCH KITCHEN CABINET SPECIFICATION SCHEME 2

FLITCH: TO BE ONE FLITCH FOR THE ENTIRE PROJECT.FLITCH SAMPLE TO BE SUBMITTED TO AND APPROVED BYCRISTINA INTERIOR DESIGN INC. PRIOR TO CLOSE OF TENDER.MATCH OF ADJACENT VENEER LEAVES: BOOKMATCHEDMATCHING WITHIN PANEL FACE: CENTER MATCHEFFECT: HALF FILLEDINSTALLATION: HORIZONTAL GRAIN INSTALLATIONWOOD PANELING TO HAVE A FLAME-SPREAD RATING UP TO 150 ATWALLS EXCEPT WITHIN EXITS OR EIXT LOBBIES. WOOD PANELING WITHIN EXITS OR EXIT LOBBIES TO HAVE AFLAME-SPREAD RATING 25 AT WALLS ; 10% OF THE WALL AREAMAY HAVE FSR OF 150NOTE: MILLWORK PRODUCTS MUST BE NAUF (NO ADDED UREAFORMALDEHYDE) NON TROPICAL WOOD MUST BE USED OR FSCCERTIFIED TROPICAL WOOD.

SUPPLIER: OLYMPIA TILESERIES: CARRARA XCOLOR: WHITECODE: OV.CX.WHT.2448.PLFINISH: POLISHEDSIZE: 24"X48"

GROUT: MAPEICOLOR: #77 FROSTJOINT: 1/8" THICK

OLYMPIA TILEPAULA NICKERSONCEL: 604-765-2799

WALL - TILE

SUPPLIER: TIERRA SOLSERIES: CONTRACT WHITE WALL TILECOLOR: WHITECODE: WPNW624MATT-RECTFINISH: MATTESIZE: 6"X24"

GROUT: MAPEICOLOR: #38 AVALANCHEJOINT: 1/8" THICK

TIERRA SOLSAL CHIRICOCEL: 604-970-5475

MANU.: BENJAMIN MOORECOLOR: OC-64 PURE WHITEPRODUCT: ULTRA SPEC 500, INTERIOR LOW SHEENPRODUCT CODE: K537MPI: QUALIFIES FOR 44 X-GREENFINISH: LOW SHEENGLOSS RANGE: 10-21%FEATURES: ZERO VOC, MPI + LEED APPROVED

WALL -MARBLE SLAB

PEBO STONETED TRANTEL: (604) 322-9188

SUPPLIER: AEON STONECOLOR: BIANCO PEARLFINISH: POLISHED

NOV. 29 2018 ISSUED FOR IDSI #3

MILLWORK / FINISHES NOTES1. PROVIDE PROPER BACKING TO ALL WALL PANELS FOR SUPPORT. ie. PLYWOOD.

2. MITRE ALL EXPOSED CORNERS, GLUE ALL CONNECTIONS.

3. CONTRACTOR TO SUPPLY SUPPORT BLOCKING TO SUIT.

4. CONTRACTOR TO CONFIRM DIMENSIONS OF ALL EQUIPMENT AND FIXTURES WITH CLIENT AND CRISTINA OBERTI INTERIOR DESIGN INC. PRIOR TOPROCEEDING. PROVIDE FILLER STRIPS ADJACENT TO ALL EQUIPMENT.

5. ALL MILLWORK SHALL BE MANUFACTURERED AND/OR INSTALLED AS PER AWMAC QUALITY STANDARDS SPECIFICATIONS MANUAL.

6. SUBMIT SHOP DRAWINGS FOR REVIEW FOR ALL MILLWORK PRIOR TO FABRICATION.

7. MILLWORK SPECIFIED FOR STAINING TO BE SHOP APPLIED. SUBMIT SAMPLE FOR CRISTINA OBERTI INTERIOR DESIGN INC.'S APPROVAL.

8. MILLWORK PRODUCTS MUST BE NAUF (NO ADDED UREA FORMALDEHYDE) NON TROPICAL WOOD MUST BE USED OR FSC CERTIFIED TROPICAL WOOD.