Data on file. For Research Use Only. Not for use in diagnostic procedures. SeqCap EZ Prime Choice Probes Discover more, sequence less Features • Fully customizable designs for human and non-human designs up to 200 Mb • Improved coverage of GC-rich regions • Compatible with our HyperCap products and workflow Benefits • Create economical custom panels for a wide range of target sizes • Less sequencing costs for challenging regions (e.g., first exons) • Convenient one-stop shop for ordering, service, and support for a complete sample prep solution SeqCap EZ Prime Choice Probes are Roche Sequencing Solution’s newest generation of DNA probes used for NGS Target Enrichment. Made using a new manufacturing process that retains the excellent enrichment properties of SeqCap EZ Choice, SeqCap Prime Choice Probes also improve the coverage of GC-rich regions. TARGETED SEQUENCING
4
Embed
SINGLE-TUBE LIBRARY SEQUENCING TARGETED …...4,000 genes). All panels were processed using the HyperCap Workflow v1.0 starting with 100 ng of Coriell Sample NA 12891. Additionally,
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Data on file.For Research Use Only. Not for use in diagnostic procedures.
SINGLE-TUBE LIBRARYCONSTRUCTION
SeqCap EZ Prime Choice ProbesDiscover more, sequence less
Features• Fully customizable designs for human and non-human designs up to 200 Mb
• Improved coverage of GC-rich regions
• Compatible with our HyperCap products and workflow
Benefits• Create economical custom panels for a wide range of target sizes
• Less sequencing costs for challenging regions (e.g., first exons)
• Convenient one-stop shop for ordering, service, and support for a complete sample prep solution
SeqCap EZ Prime Choice Probes are Roche Sequencing Solution’s newest generation of DNA probes used for NGS Target Enrichment. Made using a new manufacturing process that retains the excellent enrichment properties of SeqCap EZ Choice, SeqCap Prime Choice Probes also improve the coverage of GC-rich regions.
TARGETEDSEQUENCING
2Data on file.For Research Use Only. Not for use in diagnostic procedures.
Good enrichment starts with good probe design
• The Roche design algorithm selects probes where others may not, providing you more coverage of the target area to better enable your variant discovery research
• Design your own custom SeqCap EZ Prime Choice panel via our NimbleDesign software or work with our live design team
Figure 1. SeqCap EZ Prime Choice Probes provide superior design coverage over Supplier A. Design comparison between SeqCap EZ Prime Choice Probes and Supplier A for a 500 Kb target on chr11 (61 – 61.5 Mb). SeqCap EZ Prime Choice Probes target 20% more of the target region (362 Kb vs. 256 Kb), as illustrated by an increase in red areas, denoting more coverage of the target regions. Note: The SeqCap EZ Prime Choice design was created using Roche’s most stringent design parameters which picks only unique probes. Supplier A’s design was created using Supplier A’s online design tool using its most stringent design parameters.
Supplier A’s probe coverage SeqCap EZ Prime Choice Probes’ coverage
61,08
9,000
61,09
0,000
61,06
7,000
61, 0
68,00
061
,069,0
0061
,069,0
0061
,070,0
0061
,071,0
0061
,072,0
0061
,073,0
0061
,074,0
0061
,075,0
0061
,076,0
0061
,077,0
0061
,078,0
0061
,079,0
0061
,080,0
0061
,081,0
0061
,082,0
0061
,083,0
0061
,084,0
0061
,085,0
0061
,086,0
0061
,087,0
0061
,088,0
00
Supplier A
Target Region
SeqCap EZ Prime Choice
SeqCap EZ Prime Choice Probes: compatibility with the streamlined HyperCap WorkflowThe HyperCap Workflow integrates KAPA HyperPrep and HyperPlus Kits with our new SeqCap EZ Prime Choice Probes, enabling a complete sample prep solution that can be tailored to different applications, sample types, and starting DNA amounts. This workflow streamlines hands-on time and costs while maintaining excellent sequence data quality.
• Reduce workflow time to 1.5 days—from extracted DNA to sequencing-ready libraries
• HyperCap products include our new Roche Universal Blocking Oligo (UBO) and KAPA Dual-Indexed (96) Adapter Kit
Set up Hybridization
Figure 2. KAPA HyperPrep and HyperPlus Kits reduce library construction time by half. (A) Workflow of various library preparation kits. *Covaris shearing time is dependent on instrument, make, model, and batch size. Time estimate for the KAPA Library Preparation Kit and KAPA HyperPrep Kit do not include Covaris shearing. (B) Workflow of the SeqCap EZ target enrichment protocols.
3Data on file.For Research Use Only. Not for use in diagnostic procedures.
Input Amount
Conv
ersion
(%)
Figure 4. SeqCap EZ Prime Choice Probes resulted in more functional coverage of full genes. NGS libraries starting with100 ng of NA 12891 were 12-plexed and captured on the 4,000 gene human genetic disease content made with both SeqCap EZ Prime Choice and SeqCap EZ Choice Probes. The HyperCap Workflow v1.0 was used; first exon and full gene coverage at ≥20x depth was analyzed. The values shown for first exon and full gene are representative of an average of the 12 samples.
…and of first exons and full genesImproved coverage of first exons can lead to more complete coverage of full genes which can reduce the amount of Sanger Sequencing necessary to fill in uncovered genes, saving valuable time and resources.
• SeqCap EZ Prime Choice Probes’ improved GC-rich coverage enables 384 more first exons on average, covered at 20x vs. the same panel made with the SeqCap EZ Choice Probes
• Obtain on average 573 more genes fully covered ≥20x compared to SeqCap EZ Choice Probes
Figure 3. Significantly improved mean coverage in GC-rich regions. Three panels of varying size were created on both SeqCap EZ Choice and SeqCap EZ Prime Choice Probes for comparison. 1. SeqCap EZ Human Oncology Panel (200 Kb) 2. SeqCap EZ Human Oncology Panel (2.75 Mb) 3. SeqCap EZ Inherited Disease Panel (11 Mb, approx. 4,000 genes). All panels were processed using the HyperCap Workflow v1.0 starting with 100 ng of Coriell Sample NA 12891. Additionally, 100 ng of formalin treated Horizon TruQ sample was run on both versions of the 2.75 Mb SeqCap EZ Human Oncology Panel. In all cases, the SeqCap EZ Prime Choice Panels significantly improved normalized mean coverage vs. the SeqCap EZ Choice Panels in GC-rich regions.
SeqCap EZ Primes Choice Probes offer improved coverage…
…in GC-rich regions• SeqCap EZ Prime Choice Probes deliver consistently higher coverage in GC-rich regions (>65%) across varying design
sizes and sample types vs. SeqCap EZ Choice Probes
• On average, the coverage of GC-rich regions is 46% higher vs. SeqCap EZ Choice Probes