Page 1: Sign Standards Manual - broward.edu

SIGN STANDARDSmanualVersion 1.0 | Issued 10.13.20

Page 2: Sign Standards Manual - broward.edu

table of contents

table of contentsgeneral informationIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01Graphic Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02Insert Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03

InteriorSign Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04ADA Compliant Room Signage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08Hazard, Warning & Safety Signage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Evacuation Maps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Wayfinding | Maps, Directionals, Flags & Ceiling Mount . . . . . . . . . . . . . . . 21Vinyl Graphics & Decals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06Wall Wraps, Wall Materials & Window Film.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06Floor Decals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 07

EXteriorSign Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Wall Mounted | Directional & Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Wall Mounted | Building Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Banners | Regulatory & Informational . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Banners | Events & Informational Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34ADA Compliant Room Signage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Monument | Site ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Monument | Campus Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Monument | Directional & Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Monument | Site Entrance Directional (Double Sided) . . . . . . . . . . . . . . . . . . 43Typical Exterior Takeoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45

Page 3: Sign Standards Manual - broward.edu

INTRODUCTION | Page 01

introductionThis Interior Sign Standards Manual has been created to serve as a referenceand planning tool for facility personnel to help sign new buildings and renovateexisting buildings.

The signs, which appear inside of Broward College buildings, providethe information necessary to guide visitors and employees to their desireddestinations as well as provide life safety information. A flexible sign systemhas been designed by Takeform, an environmental graphic/signage consultingfirm located in Medina, NY, to include a family of required Exterior andInterior Signs.

Page 4: Sign Standards Manual - broward.edu

Graphic standards | Page 02

PMS 294MCopy Color

WhiteCopy Color

PMS 485CCopy Color

Typography Visual vehicle of communication.

ELEMENTS OF DESIGN What gives your project its character.

Direct PrintBackground Artwork

PMS 294M, 100% CyanAccent Artwork

CO104 WhiteBezel Finish

PMS 294M PaperWhite Copy

White PaperPMS 294M, 485C Copy

White PaperPMS 294M Copy

PMS 294M White ACM

PMS 294M .375" Painted Acrylic

White PMS 294M ACM

NaturalMetal Accent

CO601 Satin SilverApplique

Page 5: Sign Standards Manual - broward.edu

insert standards | Page 03

type a.1

Font: Palatino Bold and Palatino Regular

Insert Size: 5.59"w x 2.15"h

Name Font Size: 28 pt (.27")

Title Font Size: 20 pt (.19")

Font: Palatino Regular

PMS 294 R 255G 255B 255

R 84G 125B 187

R 33G 32B 32

Insert Size: 5.0"w x 2.39"h

Name Font Size: 40 pt (.4")

namename

type a.5

type g.1 Insert colors

NameTitle

Name

Font: Palatino Bold and Palatino Regular

Insert Size: 5.59"w x 2.15"h

Name Font Size: 28 pt (.27")

Title Font Size: 20 pt (.19")

NameTitle

Name

Page 6: Sign Standards Manual - broward.edu

interiorsignage

Page 7: Sign Standards Manual - broward.edu

Type A.1

Type s.2

Type s.3

Type s.4

Type A.3

Type A.2AType A.4

Type A.5

Type d.1

Type d.2Type d.5

Type g.1

Type g.2

Type g.wb

Type s.1

Type nh.2

Type nh.1

Type nh.1A

Type d.3

Type A.2

David RichmondAthletic Director

106BOFFICE

INTERior sign summary | Page 04

ada compliant room signageAll signage not to Scale.

hazard, warning & safety signageAll signage not to Scale.

12-2346CONFERENCEROOM

02-105

Gene Wardell 301Garth Padgham 302Art Guerra 303Ina Post 304Celeste Monroe 400Mary Morris 401Lila Wyllys 402Janet Haff 403Mary Malcuit 404Garth Padgham 405

NO STORAGE

12-2346ELECTRICAL

12-2346WOMEN

10-117WOMENS

LOCKER ROOM

timothypeterson12-2346

12-2346 CONFERENCE

12-2346STAIR

STAIR 7FLOOR 1 THRU 3

DOWN TO FLOOR 1FOR EXIT DISCHARGE

1FLOOR

ROOF ACCESS

AREA OF REFUGEAREA OF REFUGE

12-2346RESTROOM

10-117FAMILY

RESTROOM

IN USE VACANT

12-2346CONFERENCEROOM

Lockers are daily use only and will be emptied at the end of each day.

Belongings left inside lockers will be collected by campus safety and placed in the lost and found.

Hours of Operation7:30 AM – 9:30 PM

Daily Use Lockers InstructionsGaining Access:Step 1: Close door and turn handle to the

locked positionStep 2: Choose and enter a 4-digit codeStep 3: Reenter your 4-digit code and check

to ensure locker is lockedStep 4: Write or save your 4-digit code

To Unlock and Retrieve Your Belongings:Enter your 4-digit code and turn handle to open position, “Lock automatically clears for the next use.”

Hours of Operation7:30 AM – 9:30 PM

Daily Use Lockers InstructionsGaining Access:Step 1: Close door and turn handle to the

locked positionStep 2: Choose and enter a 4-digit codeStep 3: Reenter your 4-digit code and check

to ensure locker is lockedStep 4: Write or save your 4-digit code

To Unlock and Retrieve Your Belongings:Enter your 4-digit code and turn handle to open position, “Lock automatically clears for the next use.”

1

David RichmondAthletic Director

Page 8: Sign Standards Manual - broward.edu

Type C.1

Type d.4

Type wf.1

Type wf.3

Type wf.4

Type wf.6

Type wf.x

Type wf.5

Type wf.2

Type C.2

Type C.3

INTERior sign summary | Page 05

evacuation mapsAll signage not to Scale.

wayfinding | maps, directionals, flags & ceiling mountAll signage not to Scale.

IN CASE OF FIRE, DO NOT USE ELEVATORS.USE STAIRWAYS.

EVACUATION MAP

7200 Pines Boulevard, Building 68Pembroke Pines, FL 33024

YOU ARE HERE

RESTROOM

FIRE ALARM

FIRE EXTINGUISHER

PRIMARY EVACUATION ROUTE

Evac Path

IN CASE OF EMERGENCY DIAL 911ALARM SOUNDS LIKE: "RING"

ALARM LOOKS LIKE: "FLASHING STROBE"

ELEVATOR

Floor 2

STAIRWELL

SECONDARY EVACUATION ROUTE

ALL OTHER ASSISTANCE CALL:CAMPUS SAFETY-

954-201 HELP (4357)

Building #68 Room #246

245

244

254 252255256257258250A250B250C

253

250

249

246C 246B

281248 247

261

244A

263265267270

271 272 266

273274

275

276

277

279 280285

264269268

IN CASE OF FIRE, DO NOT USE ELEVATORS.USE STAIRWAYS.

EVACUATION MAP7200 Pines Boulevard, Building 68Pembroke Pines, FL 33024

YOU ARE HERE

RESTROOM

FIRE ALARM

FIRE EXTINGUISHER

PRIMARY EVACUATION ROUTE

Evac Path

IN CASE OF EMERGENCY DIAL 911ALARM SOUNDS LIKE: "RING"

ALARM LOOKS LIKE: "FLASHING STROBE"

ELEVATOR

Floor 2

STAIRWELL

SECONDARY EVACUATION ROUTE

ALL OTHER ASSISTANCE CALL:CAMPUS SAFETY-

954-201 HELP (4357)

Building #68 Room #246

245

244

254 252255256257258250A250B250C

253

250

249

246C 246B

281248 247

261

244A

263265267270

271 272 266

273274

275

276

277

279 280285

264269268

3

IN CASE OF FIRE,USE STAIR FOR EXIT.

DO NOT USE ELEVATOR.

Floor 1130 W. Exchange St., Liberty, OH 45014

EMERGENCY EXIT PLAN

IN CASE OF EMERGENCY DIAL 911ALARM SOUNDS LIKE: “RING”

ALARM LOOKS LIKE: “FLASHING STROBE”

YOU ARE HERE

RESTROOM

STAIRWELL

ELEVATOR

FIRE ALARM

FIRE EXTINGUISHER

EVACUATION ROUTE

Restroom REGISTRATION

CONFERENCE ROOM

Ground Floor Shipping/Receiving

Floor 1 Main Lobby

Accounting

Floor 2 Human Resources

Offices 200–225

Floor 3 Administration Office

Offices 300–320

Staff Lounge

DIRECTORY 2

RestroomsElevatorsStairs

Reception Desk Administrative Offices Parking Garage

TheaterDepartment

TheaterDepartment

Theater Department

Page 9: Sign Standards Manual - broward.edu

INTERior sign summary | Page 06

vinyl graphics & decalsAll signage not to Scale.

Artwork to be designed by Broward Collegeon project-by-project basis

Artwork to be designed by Broward Collegeon project-by-project basis

Wall Wraps, Wall Materials & Window FilmAll signage not to Scale.

Page 10: Sign Standards Manual - broward.edu

INTERior sign summary | Page 07

Artwork to be designed by Broward Collegeon project-by-project basis

FLOOR DECALSAll signage not to Scale.

Page 11: Sign Standards Manual - broward.edu

ada compliant room signage | Page 08VIVID CSI specs CAN BE FOUND at the END of thIS document

Type A.1VV1AW-01201207-R11C01

Overall Size: 6.0"w X 6.0"hInsert Size: 5.59"w X 2.15"h

Scale: 1:2

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

D

InsertMedia: White Paper;Font: Palatino Bold, Regular;Copy Color: White;BG: To match PMS 294MLogo: Use per RND

Use and ApplicationIdentification of offices.

InsertWindow

David RichmondAthletic Director

106BOFFICE

ADA Required Sign*ADA Guidelines for installationavailable upon request

ADA Required Sign*ADA Guidelines for installationavailable upon request

Type A.2VV1AW-012012

Overall Size: 6.0"w X 6.0"h

Scale: 1:2

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Use and ApplicationAny room that has permanent use.

12-2346CONFERENCEROOM

Page 12: Sign Standards Manual - broward.edu

ada compliant room signage | Page 09VIVID CSI specs CAN BE FOUND at the END of thIS document

Type A.2aV1AJ03

Overall Size: 6.0"w X 7.0"h

Scale: 1:2

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Use and ApplicationIdentification of conference rooms.

ADA Required Sign*ADA Guidelines for installationavailable upon request

Type A.3VV1AW-017011

Overall Size: 8.5"w X 5.5"h

Scale: 1:2

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Direct Print Copy

D To match PMS 294MFont: U.S. 101 (ADA)

Use and ApplicationBack of house (maintenance, electrical, etc.)

ADA Required Sign*ADA Guidelines for installationavailable upon request

NO STORAGE

12-2346ELECTRICAL

IN USE VACANT

12-2346CONFERENCEROOM

Page 13: Sign Standards Manual - broward.edu

ada compliant room signage | Page 10VIVID CSI specs CAN BE FOUND at the END of thIS document

Type A.5VV1AW-01300501-T11C01

Direct Print Background

A Use per RND B

InsertMedia: White Paper;Font: Palatino Bold, Regular;Copy Color: White;BG: To match PMS 294MLogo: Use per RND

Use and ApplicationIdentification of XXXXXXXXX.

Overall Size: 6.5"w X 2.5"hInsert Size: 5.59"w X 2.15"h

Scale: 1:2

Type A.4VV1AW-01301806-R12K01

Overall Size: 6.5"w X 9.0"hInsert Size: 5.59"w X 4.65"h

Scale: 1:2

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

D

InsertMedia: White Paper;Font: Palatino Regular;Copy Color: White;BG: To match PMS 294MLogo: Use per RND

Use and ApplicationIdentification of XXXXXXXXX.

ADA Required Sign*ADA Guidelines for installationavailable upon request

02-105

Gene Wardell 301Garth Padgham 302Art Guerra 303Ina Post 304Celeste Monroe 400Mary Morris 401Lila Wyllys 402Janet Haff 403Mary Malcuit 404Garth Padgham 405

InsertWindow

David RichmondAthletic Director

Insert Window

Page 14: Sign Standards Manual - broward.edu

ada compliant room signage | Page 11VIVID CSI specs CAN BE FOUND at the END of thIS document

Type d.2V1AE04

Use and ApplicationIdentification of restrooms.

ADA Required Sign*ADA Guidelines for installationavailable upon request

Overall Size: 6.5"w X 9.0"h

Scale: 1:2

12-2346RESTROOM

Type d.1V1AE04

Overall Size: 6.5"w X 9.0"h

Scale: 1:2

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Direct Print Copy

D WhiteFont: U.S. 101 (ADA)

Use and ApplicationIdentification of restrooms.

ADA Required Sign*ADA Guidelines for installationavailable upon request

12-2346WOMEN

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Direct Print Copy

D WhiteFont: U.S. 101 (ADA)

Page 15: Sign Standards Manual - broward.edu

ada compliant room signage | Page 12VIVID CSI specs CAN BE FOUND at the END of thIS document

Type d.5VV1AW-013020

Overall Size: 6.5"w X 10.0"h

Scale: 1:2

Use and ApplicationIdentification of restrooms.

ADA Required Sign*ADA Guidelines for installationavailable upon request

10-117WOMENS

LOCKER ROOM

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Direct Print Copy

D WhiteFont: U.S. 101 (ADA)

Type d.3VV1AW-013020

Use and ApplicationIdentification of restrooms.

ADA Required Sign*ADA Guidelines for installationavailable upon request

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Direct Print Copy

D WhiteFont: U.S. 101 (ADA)

Overall Size: 6.5"w X 10.0"h

Scale: 1:2

10-117FAMILY

RESTROOM

Page 16: Sign Standards Manual - broward.edu

Overall Size: 9.0"w X 2.67"hInsert Size: 5.0"w X 2.25"h

Scale: 1:2

ada compliant room signage | Page 13lucid CSI specs CAN BE FOUND at the END of thIS document

Type g.1Lucid

Type g.2Lucid

Use and ApplicationAny glass front room that has permanent use.

ADA Required Sign*ADA Guidelines for installationavailable upon request

Raised Copy

B

Lens

A

Insert

C¼" Non Glare Acrylic

Direct Print Graphic

D To match PMS 294M,100% Cyan

Paint to match PMS 294MFont: U.S. 101 (ADA)

Media: Clear;Font: Palatino Regular;Graphics/Copy Color: To match PMS 294M

Use and ApplicationIdentification of rooms.

ADA Required Sign*ADA Guidelines for installationavailable upon request

timothypeterson12-2346

Insert

Overall Size: 9.0"w X 2.67"hInsert Size: 5.0"w X 2.25"h

Scale: 1:2

Insert

Raised Copy

B

Lens

A

Insert

C¼" Non Glare Acrylic

Direct Print Graphic

D To match PMS 294M,100% Cyan

Paint to match PMS 294MFont: U.S. 101 (ADA)

Media: Clear;Font: Palatino Regular;Graphics/Copy Color: To match PMS 294M

12-2346 CONFERENCE

Page 17: Sign Standards Manual - broward.edu

ada compliant room signage | Page 14NOTICE HOLDER CSI specs CAN BE FOUND at the END of thIS document

Overall Size: 5.0"w X 2.67"h

Scale: 1:2

Use and ApplicationCovers the back of Lucid signs when mounted on glass.

Appliqué

A Thickness: .03"Finish: CO601 Satin SilverMounting: Tape Flush

Type nh.1MN8.5X11

Use and ApplicationNotice holder with insert.

Overall Size: 8.5"w X 11.9"hInsert Size: 8.5"w X 11.0"h

Scale: 3" = 1'

Type g.wbLucid Window Backer

Insert

B

Bezel Finish

A CO104 White

Media: White Paper;Font: Palatino Regular;Copy Color: To match PMS 294M

End View

Hours of Operation7:30 AM – 9:30 PM

Daily Use Lockers InstructionsGaining Access:Step 1: Close door and turn handle to the locked positionStep 2: Choose and enter a 4-digit codeStep 3: Reenter your 4-digit code and check to ensure locker is lockedStep 4: Write or save your 4-digit code

To Unlock and Retrieve Your Belongings:Enter your 4-digit code and turn handle to open position, “Lock automatically clears for the next use.”

Page 18: Sign Standards Manual - broward.edu

Overall Size: 11.0"w X 17.9"hInsert Size: 11.0"w X 17.0"h

Scale: 3" = 1'

ada compliant room signage | Page 15ACM & NOTICE HOLDER CSI specs CAN BE FOUND at the END of thIS document

Overall Size: 8.5"w X 11.0"h

Scale: 3" = 1'

Use and ApplicationPermanent notice.

ACM

AUse artwork per RND,White, To match PMS 294M, 100% Cyan;Font: U.S. 101 (ADA)

Type nh.2MN11X17

Use and ApplicationNotice holder with insert.

Type nh.1aCS8.5X11-T

Lockers are daily use only and will be emptied at the end of each day.

Belongings left inside lockers will be collected by campus safety and placed in the lost and found.

End View

Hours of Operation7:30 AM – 9:30 PM

Daily Use Lockers InstructionsGaining Access:Step 1: Close door and turn handle to the locked positionStep 2: Choose and enter a 4-digit codeStep 3: Reenter your 4-digit code and check to ensure locker is lockedStep 4: Write or save your 4-digit code

To Unlock and Retrieve Your Belongings:Enter your 4-digit code and turn handle to open position, “Lock automatically clears for the next use.”

Insert

B

Bezel Finish

A CO104 White

Media: White Paper;Font: Palatino Regular;Copy Color: To match PMS 294M

Page 19: Sign Standards Manual - broward.edu

ada compliant room signage | Page 16VIVID CSI specs CAN BE FOUND at the END of thIS document

Type s.1V1AE04

Overall Size: 6.5"w X 9.0"h

Scale: 1:2

Use and ApplicationIdentification of stairs.

ADA Required Sign*ADA Guidelines for installationavailable upon request

12-2346STAIR

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Direct Print Copy

D WhiteFont: U.S. 101 (ADA)

Page 20: Sign Standards Manual - broward.edu

hazard, warning & safety signage | Page 17ACM CSI specs CAN BE FOUND at the END of thIS document

Type s.2CS16,3X18-T

Use and ApplicationFire safety signage.

ADA Required Sign*ADA Guidelines for installationavailable upon request

Type s.3CS8,5X9,5-T

Overall Size: 16.3"w X 18.0"h

Scale: 3" = 1'

Overall Size: 8.5"w X 9.5"h

Scale: 3" = 1'

Use and ApplicationFire safety signage.

ADA Required Sign*ADA Guidelines for installationavailable upon request

STAIR 7FLOOR 1 THRU 3

DOWN TO FLOOR 1FOR EXIT DISCHARGE

1FLOOR

ROOF ACCESS

ACM

A Use artwork per RND,White, To match PMS 294M;Font: U.S. 101 (ADA)

ACM

A Use artwork per RND,White, To match PMS 294M;Font: U.S. 101 (ADA)

AREA OF REFUGEAREA OF REFUGE

Page 21: Sign Standards Manual - broward.edu

hazard, warning & safety signage | Page 18VIVID CSI specs CAN BE FOUND at the END of thIS document

Type s.4V1AH11

Use and ApplicationStairwell safety signage.

ADA Required Sign*ADA Guidelines for installationavailable upon request

Overall Size: 5.0"w X 5.0"h

Scale: 1:2

1

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Page 22: Sign Standards Manual - broward.edu

evacuation maps | Page 19VIVID CSI specs CAN BE FOUND at the END of thIS document

Type C.1Custom

Direct Print Background

A Use per RND

B

Direct Print Copy

To match PMS 294MFont: U.S. 101 (ADA)

C

Direct Print Copy

To match PMS 485CFont: U.S. 101 (ADA)

D

Evac InsertMedia: White Paper;Font: U.S. 101 (ADA);Copy Color: To match PMS 294M, 485C

Use and ApplicationDesignate evacuation routes.

ADA Required Sign*ADA Guidelines for installationavailable upon request

Type C.2Custom

Overall Size: 17.5"w X 15.0"hInsert Size: 17.5"w X 11.0"h

Scale: 3" = 1'

Overall Size: 11.5"w X 11.0"hInsert Size: 11.0"w X 8.5"h

Scale: 3" = 1'

Use and ApplicationDesignate evacuation routes.

ADA Required Sign*ADA Guidelines for installationavailable upon request

IN CASE OF FIRE, DO NOT USE ELEVATORS.USE STAIRWAYS.

EVACUATION MAP

7200 Pines Boulevard, Building 68Pembroke Pines, FL 33024

YOU ARE HERE

RESTROOM

FIRE ALARM

FIRE EXTINGUISHER

PRIMARY EVACUATION ROUTE

Evac Path

IN CASE OF EMERGENCY DIAL 911ALARM SOUNDS LIKE: "RING"

ALARM LOOKS LIKE: "FLASHING STROBE"

ELEVATOR

Floor 2

STAIRWELL

SECONDARY EVACUATION ROUTE

ALL OTHER ASSISTANCE CALL:CAMPUS SAFETY-

954-201 HELP (4357)

Building #68 Room #246

245

244

254 252255256257258250A250B250C

253

250

249

246C 246B

281248 247

261

244A

263265267270

271 272 266

273274

275

276

277

279 280285

264269268

InsertWindow

IN CASE OF FIRE, DO NOT USE ELEVATORS.USE STAIRWAYS.

EVACUATION MAP7200 Pines Boulevard, Building 68Pembroke Pines, FL 33024

YOU ARE HERE

RESTROOM

FIRE ALARM

FIRE EXTINGUISHER

PRIMARY EVACUATION ROUTE

Evac Path

IN CASE OF EMERGENCY DIAL 911ALARM SOUNDS LIKE: "RING"

ALARM LOOKS LIKE: "FLASHING STROBE"

ELEVATOR

Floor 2

STAIRWELL

SECONDARY EVACUATION ROUTE

ALL OTHER ASSISTANCE CALL:CAMPUS SAFETY-

954-201 HELP (4357)

Building #68 Room #246

245

244

254 252255256257258250A250B250C

253

250

249

246C 246B

281248 247

261

244A

263265267270

271 272 266

273274

275

276

277

279 280285

264269268

InsertWindow

Direct Print Background

A Use per RND

B

Direct Print Copy

To match PMS 294MFont: U.S. 101 (ADA)

C

Direct Print Copy

To match PMS 485CFont: U.S. 101 (ADA)

D

Evac InsertMedia: White Paper;Font: U.S. 101 (ADA);Copy Color: To match PMS 294M, 485C

Page 23: Sign Standards Manual - broward.edu

evacuation maps | Page 20VIVID CSI specs CAN BE FOUND at the END of thIS document

Type C.3Custom

D

Evac InsertMedia: White Paper;Font: U.S. 101 (ADA);Copy Color: To match PMS 294M, 485C

B

Direct Print Copy

To match PMS 294MFont: U.S. 101 (ADA)

Direct Print Graphic

B

Direct Print Background

A Use per RND

To match PMS 294M,100% Cyan

Use and ApplicationDesignate evacuation routes.

ADA Required Sign*ADA Guidelines for installationavailable upon request

Overall Size: 12.0"w X 22.5"hInsert Size: 11.0"w X 17.0"h

Scale: 3" = 1'

3

IN CASE OF FIRE,USE STAIR FOR EXIT.

DO NOT USE ELEVATOR.

Floor 1130 W. Exchange St., Liberty, OH 45014

EMERGENCY EXIT PLAN

IN CASE OF EMERGENCY DIAL 911ALARM SOUNDS LIKE: “RING”

ALARM LOOKS LIKE: “FLASHING STROBE”

YOU ARE HERE

RESTROOM

STAIRWELL

ELEVATOR

FIRE ALARM

FIRE EXTINGUISHER

EVACUATION ROUTE

Page 24: Sign Standards Manual - broward.edu

wayfinding | Page 21VIVID CSI specs CAN BE FOUND at the END of thIS document

Type d.4V1AM05

Overall Size: 10.0"w X 10.0"h

Scale: 3" = 1'

Overall Size: 85.0"w X 15.0"h

Scale: 1" = 1'

Direct Print Graphic

B

Direct Print Background

A

Direct Print Copy

CUse per RND To match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Direct Print Copy

D WhiteFont: U.S. 101 (ADA)

Use and ApplicationIdentification of restrooms.

Restroom

WA

LL

REGISTRATION

Type wf.1VV1AW-170030

Use and ApplicationWayfinding destination points.

Direct Print Graphic

B

Direct Print Background

A

Direct Print Copy

CUse per RND To match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Page 25: Sign Standards Manual - broward.edu

wayfinding | Page 22VIVID CSI specs CAN BE FOUND at the END of thIS document

Type WF.2V1AC01

Overall Size: 44.0"w X 7.0"h

Scale: 1 ½" = 1'

Direct Print Graphic

B

Direct Print Background

A

Direct Print Copy

CUse per RND To match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Use and ApplicationWayfinding destination points.

Type wf.3V1AA05

Use and ApplicationWayfinding directory.

CONFERENCE ROOM

C E I L I N G

Overall Size: 23.0"w X 42.0"hInsert Size: 22.09"w X 33.65"h

Scale: 1 ½" = 1'

Ground Floor Shipping/Receiving

Floor 1 Main Lobby

Accounting

Floor 2 Human Resources

Offices 200–225

Floor 3 Administration Office

Offices 300–320

Staff Lounge

DIRECTORY

InsertWindow

Direct Print Graphic

B

Direct Print Background

A

Direct Print Copy

CUse per RND To match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

D

InsertMedia: White Paper;Font: Palatino Regular;Copy Color: White;BG: To match PMS 294MLogo: Use per RND

Page 26: Sign Standards Manual - broward.edu

Overall Size: 23.0"w X 42.0"hInsert Size: 22.09"w X 33.65"h

Scale: 1 ½" = 1'

wayfinding | Page 23VIVID CSI specs CAN BE FOUND at the END of thIS document

Type WF.4Custom Vivid

Use and ApplicationWayfinding directional.

Type wf.5VV1AW-034024

Use and ApplicationFlag mounted wayfinding directional.

Direct Print Graphic

B

Direct Print Background

A

Direct Print Copy

CUse per RND To match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

2

RestroomsElevatorsStairs

Reception Desk Administrative Offices Parking Garage

InsertWindow

Direct Print Graphic

B

Direct Print Background

A

Direct Print Copy

CUse per RND To match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

D

InsertMedia: White Paper;Font: Palatino Regular;Copy Color: White;BG: To match PMS 294MLogo: Use per RND

Overall Size: 17.0"w X 12.0"h

Scale: 3" = 1'

WA

LL

TheaterDepartment

Page 27: Sign Standards Manual - broward.edu

Overall Size: 44.0"w X 7.0"hLens Size: 37.0"w X 5.5"h

Scale: 1 ½" = 1'

wayfinding | Page 24VIVID CSI specs CAN BE FOUND at the END of thIS document

Type WF.6VV1AF-034034

Use and ApplicationFlag mounted wayfinding destination points.

Type wf.xCustom | Backer: VV1AW-088014

Use and ApplicationInterchangeable wayfinding destination points.

Direct Print Graphic

B

Direct Print Background

A

Lens

DUse per RND

Direct Print Copy

C To match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Metal Accent

E

.125" Non-Glare Acrylic

Natural, .625" dia. caps;w/.25" Stand-offs

Direct Print Graphic

B

Direct Print Background

A

Direct Print Copy

CUse per RND To match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Overall Size: 17.0"w X 17.0"h

Scale: 3" = 1'

WA

LL

TheaterDepartment

Theater Department

Page 28: Sign Standards Manual - broward.edu

exteriorsignage

Page 29: Sign Standards Manual - broward.edu

exterior sign summary | Page 25

monument | site idAll signage not to Scale.

monument | campus mapAll signage not to Scale.

NORTH CAMPUS — 1000

Type E.1

Type E.2

Broward College Buildings1 Administration, Social Sciences, Behavioral Sciences2 Classrooms, College Academy3 Visual Arts4 Bailey Concert Hall, Performing Arts, Music, Classrooms5 Classrooms6 Fine Arts Theatre, English7 Biological/Physical Science/Math8 Health Sciences9 Business Administration, Communications, Nursing BSN10 Gym, Classrooms11 Wellness13 Computer Sciences, Engineering14 Classrooms/ESL/Offices15 Classrooms16 Buehler Planetarium17 University/College Library, Learning Resources18 Buehler Observatory19 Ferris Admissions & Student Affairs Center, Admissions, Bookstore, Cashier’s Office, Counseling, Registration, Campus Safety, Student Financial Services, Student Life20 Printing & Graphic Arts Service21 Institute for Public Safety22 Institute for Public Safety

23 Physical Plant24 Vehicle Maintenance25 Grounds, Building Maintenance, Facilities27 Child Development Center28 Aquatic Complex36 Parking Garage411 CaféFlorida Atlantic University Buildings49 Liberal Arts Building51 Wellness Center52 Education and Science Building53 Greenhouse54 Student Services BuildingALL ELEVATOR PHONES ACT AS CALL BOXES

EMERGENCY CALL BOX LOCATIONS

CARPOOL PARKING

CAMPUS SAFETY OFFICE

FLORIDA ATLANTIC UNIVERSITY

BROWARD COLLEGE

WATERWAYS

STOP LIGHT LOCATIONS

SMOKING AREAS

PARKING LOT / PARKING GARAGE

BUS STOP LOCATION

CAMPUS MAP

Page 30: Sign Standards Manual - broward.edu

exterior sign summary | Page 26

monument | directional & identificationAll signage not to Scale.

monument | site entrance directionalAll signage not to Scale.

Type E.3 Type E.5

Type E.4

ADMISSIONS &REGISTRATION

ShuttleService

May-Ann LICUDINE

Library

EntrancesMAIN ENTR ANCENORTH CAMPUS

VISITOR CENTERADMIS SIONS

Exit

Bu

ehle

r O

BSER

VATO

RY

Page 31: Sign Standards Manual - broward.edu

exterior sign summary | Page 27

wall mounted | directional & identificationAll signage not to Scale.

wall mounted | building identificationAll signage not to Scale.

Type E.6

Type E.7

Type E.6.1

ADMISSIONS &REGISTRATION

ShuttleService

May-AnnLibrary

ADMISSIONS &REGISTRATION

ShuttleService

May-AnnLibrary

Page 32: Sign Standards Manual - broward.edu

exterior sign summary | Page 28

ada compliant room signageAll signage not to Scale.

Type E.11

Type d.1x

Type d.2x Type d.5x

Type s.2x

Type s.3x

Type s.4x

Type s.1xType d.3x

NO STORAGE

12-2346ELECTRICAL

12-2346WOMEN

12-2346RESTROOM

10-117FAMILY

RESTROOM

10-117WOMENS

LOCKER ROOM

12-2346STAIR

STAIR 7FLOOR 1 THRU 3

DOWN TO FLOOR 1FOR EXIT DISCHARGE

1FLOOR

ROOF ACCESS

AREA OF REFUGEAREA OF REFUGE

1

Page 33: Sign Standards Manual - broward.edu

exterior sign summary | Page 29

banners | regulatory & informationalAll signage not to Scale.

banners | events & informational postsAll signage not to Scale.

welcome to

welcome to

welcome to

welcome to

WELCOME TO

WELCOME TO

Type E.10Option 1

Type E.10Option 2

Type E.10Option 3

welcome to

welcome to

welcome to

welcome to

WELCOME TO

WELCOME TO

Type E.10Option 1

Type E.10Option 2

Type E.10Option 3

Page 34: Sign Standards Manual - broward.edu

MOnuMENT | DIRECTIONAL OR IDENTIFICATION | Page #

Type E.6Internally Illuminated Wall CabinetMechanically Fasten to Building FasciaMounting Hardware to Suit Wall Construction

Use and ApplicationPedestrian directional.

Front Panel

A Painted, Routed .125 AluminumTo match PMS Cool Gray 1 C / PMS 294 C / CO601 Satin Silver

24.0"

36.0"

8.0"

Side A Profile

ADMISSIONS &REGISTRATION

ShuttleService

May-AnnLibrary

MountingSurface

A

B

wall mounted | DIRECTIONAL OR IDENTIFICATION | Page 30

Illuminated Copy

B 3/16" Translucent Acrylic BackerFont: US 101 (ADA) & RegularTo match PMS 299 C / 7328 White

Page 35: Sign Standards Manual - broward.edu

MOnuMENT | DIRECTIONAL OR IDENTIFICATION | Page #

Type E.6.1Wall PanelStand Off - 1/2"Mounting Hardware to Suit Wall Construction

Use and ApplicationPedestrian directional.

Front Panel

A Painted .125 Aluminumto match PMS Cool Gray 1 C / PMS 294 C / CO601 Satin Silver

wall mounted | DIRECTIONAL OR IDENTIFICATION | Page 31

Copy

B First Surface Applied VinylFont: US 101 (ADA) & RegularTo match PMS 299 C / 220-10 White

Side A Profile

24.0"

36.0"

0.50"

ADMISSIONS &REGISTRATION

ShuttleService

MountingSurface

A

B

May-AnnLibrary

Page 36: Sign Standards Manual - broward.edu

MOnuMENT | DIRECTIONAL OR IDENTIFICATION | Page #

Type E.7Face Lit Channel LettersLED IlluminationMechanically Fasten to Building FasciaMounting Hardware to Suit Construction

Use and ApplicationPedestrian directional.

Faces

A3/16" Translucent Acrylic Faces w/First Surface Translucent VinylFont: Customer Supplied Artwork3M Dual Color Film 3635-210 paintedto match PMS 294 C / 7328 White

Returns

CPainted 4" Deep .040 Aluminum Channel CoilTo match PMS 294 C

1" Trim CapBlack

wall mounted | building IDENTIFICATION | Page 32

Trim Cap

B

Profile

Mounting Surface

C

TBD

TBD

A

B

Page 37: Sign Standards Manual - broward.edu

MOnuMENT | DIRECTIONAL OR IDENTIFICATION | Page #

Use and ApplicationPedestrian directional.

wall mounted | building IDENTIFICATION | Page 33

4”

Profile

Mounting Surface

Face Lit Channel Letter - Typ.NTSDoes not Reflect Actual Mounting ConditionsSite Survey Required

Profile

Mounting Surface

4.00"

A3/16” Translucent Acrylic Faces w/ First Surface Translucent Vinyl Font: Customer Supplied Artwork3M Dual Color Film 3635-210 painted to match PMS 294 C / 7328 White

Faces

Trim Cap

B 1” Trim CapBlack

Returns

DPainted 4” Deep .040 Aluminum Channel Coilto match PMS 294 C

DC

Extruded AluminumRaceway

3.50"

TBD

TBD

TBD

TBD

A

B

Type E.8Face Lit Channel Letters/NumbersSolar Powered LED IlluminationMechanically Fasten to Building FasciaMounting Hardware to Suit Construction

Page 38: Sign Standards Manual - broward.edu

banners | Regulatory & Informational | Page 34

Type E.10Double Sided BannerMount to Existing Light Pole w/Adjustable Banner Brackets andFiberglass Banner Arms (as required)

Use and ApplicationCollege exterior branding.

Banner

A Digital Print to 22oz Blackout Vinyl w/ Top and Bottom Pole Pockets and GrommetsCDD-22MB to match TBD

Mounting

B KBW BannerFlex Metro BracketBlack

welcome to

welcome to

19.0"

1.375"

48.0"

3.0"

A B

Side A

C

welcome to

welcome to

welcome to

welcome to

WELCOME TO

WELCOME TO

Option 1 Option 2 Option 3

Page 39: Sign Standards Manual - broward.edu

ada compliant room signage | Page 35VIVID CSI specs CAN BE FOUND at the END of thIS document

Type E.11VV1AW-017011

Overall Size: 8.5"w X 5.5"h

Scale: 1:2

Use and ApplicationIdentification of rooms.

ADA Required Sign*ADA Guidelines for installationavailable upon request

Type d.1xV1AE04

ADA Required Sign*ADA Guidelines for installationavailable upon request

NO STORAGE

12-2346ELECTRICAL

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Direct Print Copy

D To match PMS 294MFont: U.S. 101 (ADA)

Overall Size: 6.5"w X 9.0"h

Scale: 1:2

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Direct Print Copy

D WhiteFont: U.S. 101 (ADA)

Use and ApplicationIdentification of restrooms.

12-2346WOMEN

Page 40: Sign Standards Manual - broward.edu

ada compliant room signage | Page 36VIVID CSI specs CAN BE FOUND at the END of thIS document

Type d.2xV1AE04

ADA Required Sign*ADA Guidelines for installationavailable upon request

ADA Required Sign*ADA Guidelines for installationavailable upon request

Use and ApplicationIdentification of restrooms.

Overall Size: 6.5"w X 9.0"h

Scale: 1:2

12-2346RESTROOM

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Direct Print Copy

D WhiteFont: U.S. 101 (ADA)

Type d.3xVV1AW-013020

Use and ApplicationIdentification of restrooms.

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Direct Print Copy

D WhiteFont: U.S. 101 (ADA)

Overall Size: 6.5"w X 10.0"h

Scale: 1:2

10-117FAMILY

RESTROOM

Page 41: Sign Standards Manual - broward.edu

ada compliant room signage | Page 37VIVID CSI specs CAN BE FOUND at the END of thIS document

Type d.5xVV1AW-013020

ADA Required Sign*ADA Guidelines for installationavailable upon request

ADA Required Sign*ADA Guidelines for installationavailable upon request

Type S.1xV1AE04

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Direct Print Copy

D WhiteFont: U.S. 101 (ADA)

Overall Size: 6.5"w X 10.0"h

Scale: 1:2

Use and ApplicationIdentification of restrooms.

10-117WOMENS

LOCKER ROOM

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Direct Print Copy

D WhiteFont: U.S. 101 (ADA)

Overall Size: 6.5"w X 9.0"h

Scale: 1:2

Use and ApplicationIdentification of stairs.

12-2346STAIR

Page 42: Sign Standards Manual - broward.edu

ada compliant room signage | Page 38ACM CSI specs CAN BE FOUND at the END of thIS document

Type s.2xCS16,3X18-T

Use and ApplicationFire safety signage.

ADA Required Sign*ADA Guidelines for installationavailable upon request

Type s.3xCS8,5X9,5-T

Overall Size: 16.3"w X 18.0"h

Scale: 3" = 1'

Overall Size: 8.5"w X 9.5"h

Scale: 3" = 1'

Use and ApplicationFire safety signage.

ADA Required Sign*ADA Guidelines for installationavailable upon request

STAIR 7FLOOR 1 THRU 3

DOWN TO FLOOR 1FOR EXIT DISCHARGE

1FLOOR

ROOF ACCESS

ACM

A Use artwork per RND,White, To match PMS 294M;Font: U.S. 101 (ADA)

ACM

A Use artwork per RND,White, To match PMS 294M;Font: U.S. 101 (ADA)

AREA OF REFUGEAREA OF REFUGE

Page 43: Sign Standards Manual - broward.edu

ada compliant room signage | Page 39VIVID CSI specs CAN BE FOUND at the END of thIS document

Type s.4xV1AH11

Use and ApplicationStairwell safety signage.

ADA Required Sign*ADA Guidelines for installationavailable upon request

Overall Size: 5.0"w X 5.0"h

Scale: 1:2

1

Direct Print Graphic

B

Direct Print Background

A

Raised Copy

CUse per RND Paint to match PMS 294MFont: U.S. 101 (ADA)

To match PMS 294M,100% Cyan

Page 44: Sign Standards Manual - broward.edu

MOnuMENT | SITE ID | Page 40

Type E.1Double Sided, Internally Illuminated Monument CabinetLED IlluminationFlange Mount to Concrete Base

Use and ApplicationSite identification.

Side A Side B

Plan View

Profile Right4.00"

16.0"96.0"

23.0"

NORTH CAMPUS — 1000 NORTH CAMPUS — 1000

A E

B

D

F G

C

48.0" 36.0"

Logo & Address Cabinet

B

Front Panel

A

Illuminated Copy

CPainted .125" AluminumTo match PMS Cool Gray 1 C

Push Thru ¾" White Acrylic ½" Proud of Facew/ First Surface Applied Translucent VinylFont: Customer Supplied Logo / US 101 (ADA) & Regular220-10 White

Painted Routed 3" Deep Fabricated AluminumTo match PMS 294 C

Break Line

D First Surface Applied Vinyl220-10 White

Accent Bar

E

Mounting Assembly

F Painted Aluminum Flange w/ Concrete AnchorsTo match PMS Cool Gray 1 C

Painted 1 ½" AluminumCO601 Satin Silver

Masonry

G Poured Concrete - Pier Footer w/ Pad

105.0"

Labor IntensiveFoundation Required

Page 45: Sign Standards Manual - broward.edu

MOnuMENT | campus map | Page 41

Type E.2Double Sided, Internally Illuminated Monument CabinetLED IlluminationFlange Mount to Concrete Base

Use and ApplicationCampus map.

Front Panel

A Painted .125" AluminumTo match PMS Cool Gray 1 C

Accent Bar

B Painted 1 ½" AluminumCO601 Satin Silver

Map Cabinet

D

Illuminated Map Panel

E 3/16" Translucent Acrylic Backerw/ First Surface Applied Digital PrintGraphic: TBDTo match 7328 White

Masonry

G Poured Concrete - Pier Footer w/ Pad

Side A Side B

Plan View

84.0"

40.0" 37.0"

23.0"

Broward College Buildings1 Administration, Social Sciences, Behavioral Sciences2 Classrooms, College Academy3 Visual Arts4 Bailey Concert Hall, Performing Arts, Music, Classrooms5 Classrooms6 Fine Arts Theatre, English7 Biological/Physical Science/Math8 Health Sciences9 Business Administration, Communications, Nursing BSN10 Gym, Classrooms11 Wellness13 Computer Sciences, Engineering14 Classrooms/ESL/Offices15 Classrooms16 Buehler Planetarium17 University/College Library, Learning Resources18 Buehler Observatory19 Ferris Admissions & Student Affairs Center, Admissions, Bookstore, Cashier’s Office, Counseling, Registration, Campus Safety, Student Financial Services, Student Life20 Printing & Graphic Arts Service21 Institute for Public Safety22 Institute for Public Safety

23 Physical Plant24 Vehicle Maintenance25 Grounds, Building Maintenance, Facilities27 Child Development Center28 Aquatic Complex36 Parking Garage411 CaféFlorida Atlantic University Buildings49 Liberal Arts Building51 Wellness Center52 Education and Science Building53 Greenhouse54 Student Services BuildingALL ELEVATOR PHONES ACT AS CALL BOXES

EMERGENCY CALL BOX LOCATIONS

CARPOOL PARKING

CAMPUS SAFETY OFFICE

FLORIDA ATLANTIC UNIVERSITY

BROWARD COLLEGE

WATERWAYS

STOP LIGHT LOCATIONS

SMOKING AREAS

PARKING LOT / PARKING GARAGE

BUS STOP LOCATION

CAMPUS MAP

Broward College Buildings1 Administration, Social Sciences, Behavioral Sciences2 Classrooms, College Academy3 Visual Arts4 Bailey Concert Hall, Performing Arts, Music, Classrooms5 Classrooms6 Fine Arts Theatre, English7 Biological/Physical Science/Math8 Health Sciences9 Business Administration, Communications, Nursing BSN10 Gym, Classrooms11 Wellness13 Computer Sciences, Engineering14 Classrooms/ESL/Offices15 Classrooms16 Buehler Planetarium17 University/College Library, Learning Resources18 Buehler Observatory19 Ferris Admissions & Student Affairs Center, Admissions, Bookstore, Cashier’s Office, Counseling, Registration, Campus Safety, Student Financial Services, Student Life20 Printing & Graphic Arts Service21 Institute for Public Safety22 Institute for Public Safety

23 Physical Plant24 Vehicle Maintenance25 Grounds, Building Maintenance, Facilities27 Child Development Center28 Aquatic Complex36 Parking Garage411 CaféFlorida Atlantic University Buildings49 Liberal Arts Building51 Wellness Center52 Education and Science Building53 Greenhouse54 Student Services BuildingALL ELEVATOR PHONES ACT AS CALL BOXES

EMERGENCY CALL BOX LOCATIONS

CARPOOL PARKING

CAMPUS SAFETY OFFICE

FLORIDA ATLANTIC UNIVERSITY

BROWARD COLLEGE

WATERWAYS

STOP LIGHT LOCATIONS

SMOKING AREAS

PARKING LOT / PARKING GARAGE

BUS STOP LOCATION

CAMPUS MAP

Profile

16.0"

54.0"

A

C

D

E

B

F G

Illuminated Copy

C 3/16" Translucent Acrylic BackerFont: US 101 (ADA) & RegularTo match 7328 White

Painted Routed 3" Deep Fabricated AluminumTo match PMS 294 C

Mounting Assembly

F Painted Aluminum Flange w/ Concrete AnchorsTo match PMS Cool Gray 1 C

Labor IntensiveFoundation Required

Page 46: Sign Standards Manual - broward.edu

MOnuMENT | DIRECTIONAL OR IDENTIFICATION | Page 42

Type E.3Double Sided, Internally Illuminated Monument CabinetLED IlluminationFlange Mount to Concrete Base

Use and ApplicationVehicle & pedestrian directional.

Front Panel

A Painted .125" AluminumTo match PMS Cool Gray 1 C

Accent Bar

B Painted 1 ½" AluminumCO601 Satin Silver

Address Cabinet

C Painted Routed 3" Deep Fabricated AluminumTo match PMS 294 C

Illuminated Copy

D 3/16" Translucent Acrylic BackerFont: US 101 (ADA) & RegularTo match PMS 299 C / 7328 White

Mounting Assembly

E Painted Aluminum Flange w/ Concrete AnchorsTo match PMS Cool Gray 1 C

Masonry

F Poured Concrete - Pier Footer w/ Pad

Side A

Plan View

Profile

16.0"

Side B

36.0"

60.0"

ADMISSIONS &REGISTRATION

ShuttleService

May-Ann LICUDINE

Library

ADMISSIONS &REGISTRATION

ShuttleService

May-Ann LICUDINE

Library

42.0"

52.00"

C

A

D

22.0"

B

E F

Labor IntensiveFoundation Required

Page 47: Sign Standards Manual - broward.edu

MOnuMENT | site entrance DIRECTIONAL | Page 43

Type E.4Double Sided, Internally Illuminated Monument CabinetLED IlluminationFlange Mount to Concrete Base

Use and ApplicationVehicle directional.

Front Panel

A Painted .125" AluminumTo match PMS Cool Gray 1 C

Side A

Plan View

Profile Right

16.0"

Side B

48.0"

72.0"

78.0"

EntrancesMAIN ENTR ANCENORTH CAMPUS

VISITOR CENTERADMIS SIONS

Exit

EntrancesMAIN ENTR ANCENORTH CAMPUS

VISITOR CENTERADMIS SIONS

Exit

C

D

A B

60.0"

22.0"

Accent Bar

B Painted 1 ½" AluminumCO601 Satin Silver

Address Cabinet

C Painted Routed 3" Deep Fabricated AluminumTo match PMS 294 C

Illuminated Copy

D 3/16" Translucent Acrylic BackerFont: US 101 (ADA) & RegularTo match 7328 White

Mounting Assembly

E Painted Aluminum Flange w/ Concrete AnchorsTo match PMS Cool Gray 1 C

Masonry

F Poured Concrete - Pier Footer w/ Pad

E F

Labor IntensiveFoundation Required

Page 48: Sign Standards Manual - broward.edu

MOnuMENT | DIRECTIONAL OR IDENTIFICATION | Page 44

Type E.5Graphic Pylon - SmallDouble Sided, Internally Illuminated Monument CabinetLED IlluminationFlange Mount to Concrete Base

Use and ApplicationPedestrian marker.

Cabinet

A Painted, Fabricated AluminumTo match PMS Cool Gray 1 C

Halo-Illuminated Pan

B Painted, Routed, Fabricated Aluminum w/3/16" Clear Polycarbonate LensTo match PMS 249 C

Dimensional Copy

C

Logo Copy

DFirst surface applied vinyl220-10 White

Painted, Flat Cut ½" AcrylicMechanically Fasten Flush to Face from Inside of CabinetFont: Helvetica Neue Lt STD - 75 BoldTo match PMS 249 C

Masonry

H Poured Concrete - Sonotube Pier Footer

Side A End View Side B End View

14.5"17.0"

82.0"

70.0"

12.5"4.5"

6.0"

A

B

H

G

Bue

hle

r O

BSER

VATO

RY

Bue

hle

r O

BSER

VATO

RY

C

D

F

Bue

hle

r O

BSER

VATO

RY

E

Accent Bar

E Painted ½" AluminumCO601 Satin Silver

Reveal

G Painted ½" Aluminum PlateMP33260 Twilight Zone

Halo-Illuminated Copy

FPush-thru ¾" Clear Acrylic ½" Proud of Pan Face w/First Surface Applied Painted .063 Aluminum Faces andSecond Surface Applied White Diffuser FilmTo match CO104 White

Labor IntensiveFoundation Required

Page 49: Sign Standards Manual - broward.edu

EXTERIOR TAKEOFF | Page 45

5

5

5

5

5

5

5

55

5

5

55

5

5

5

5

5

5

5

5

55

5

5

5

5

5

4

4

4

4

5

5

5

5

5

5

5

5

5

5

5

6.1 6.2

6.1

6.26.1 6.2

6.1 6.2

5

6.1

6.2

4

6.1

6.2

6.16.2

6.1

6.2

6.1

6.2

6.1

6.2

6.1

6.26.1 6.26.1 6.2

6.16.2

6.1

6.2

6.1

6.2

5

6.1

6.2

6.1

6.2

6.1

6.2

6.1

6.2

6.1

6.2

5

6.1

6.2

6.1

6.2

6.1

6.2

4

4

4

1

1

2

2

2

2

2

2

2

2

2

3

3

3

3

3

7

9

GRAPHICSIGN

STANDARD TRAFFIC SIGN

BUILDING IDSIGN

PEDESTRIANSIGN

VEHICULARSIGN

LEGEND

SIGN TYPE

X.11

SIGN #

SIDE A

SIDE B

Signage Qty

1 22 93 54 85 42

6.1 246.2 247 19 1

PROJECT TOTALS

TYPICAL EXTERIOR TAKEOFF