Nov 28, 2015
SIEMENS LMV Linkageless System
User friendly
High performance and accuracySuperior product reliability Price competitiveExcellent customer support
LMV51.040 Base UnitIncludes flame safeguard
Includes parallel positioning ratio control system
Includes valve proving system
Dual fuel applications
Accepts up to 4 actuators, 3 run simultaneously
For use with external RWF40 temperature/pressure controller Includes Modbus communications
FlameSafeguard
Parallel Positioning
Valve Proving
LMV51.140 Base Unit
Same features as LMV51.040
Additional features:Includes internal temperature / pressure controllerAccepts analog firing rate signal
Flame SafeguardParallel PositioningValve Proving
Internal Load Controller
LMV52.240 Base Unit
Same features as LMV51.140
Additional features:
Optional O2 Trim w/ Efficiency Calculation
Fuel Metering (rate & totalization for each fuel)VSD channel with actual feedback of motor rpm & rotationAccepts up to 6 actuators, 5 run simultaneously
Flame SafeguardParallel PositioningValve Proving
Internal Load Controller
LMV5 Internal Load Controller
Temperature/pressure sensor connected directly to LMV5
Fully adjustable PID tuning loopAuto-tune featureDefault tuning parameters for slow, normal, & fast responding applicationsPID tuning constants can also be manually entered
Cold-start thermal shock protectionBased on time, temperature, or both
LMV5x CommissioningCommissioning can be performed via AZL keypad or optional ACS software
No laptop required
Fuel-air ratio curve may include up to 15 points Completely independent ignition position
Added reliabilityBetter turndown
Add/delete points anywhere on firing curveEach point is stored before proceeding to next oneRatio curve can be programmed with burner ON or OFFLoad masking for troubled firing ratesFGR actuator hold based on either time or stack temperature
AZL Main Features Multi-level password protection for added Security
MODBUS® Ethernet port on back for communication to BMS or PL
Bright backlit display!!
Serial port on front for use with ACS 450 software
No requirement to interface PC
User-friendly, menu system for quick programming, start-up, and commissioning
Redundant parameter back-up
QRI Infrared Flame Detector
QRI - FeaturesInfrared detector, also requires random flickering of flame
Self-checking for use on continuous operation applications
No mechanical shutter High reliability
Insensitive against ignition spark & spark reflection, daylight and artificial light, and line harmonics
Flame signal amplifier integrated into QRI
High sensitivity - applicable for low NOx burner applications
Flame signal strength via AZL display
SQM4 Linkageless Actuators
3-torque ratings
SQM45 » 30 in-lbs SQM48.4 » 180 in-lbs SQM48.6 » 310 in-lbs
Internal protection prevents actuators from damage as a result of over torque
Internal thermostat prevents actuator from over-heating
Same mounting footprint for all models
Adjustable stroke timing via AZL keypad
SQM4 CANbus Technology
Digital CANbus signal offers high accuracy and safety
900 motor positions in 90° of rotation of the stepper motor
Digital feedback signal ensures accurate positioning
LOCKOUT will occur if actuator is out-of-position
System continuously monitors the integrity of CANbus wiring
Actuators are daisy-chained on single cable
SQM4 Actuator Commissioning
No calibration required!Actuators factory shipped in zero positionActuators will automatically re-position themselves
Actuator addressing via CAN-bus
Direction of rotation is easily changed via AZL display
ID, serial numbers, date codes automatically stored in LMV
VSD - Variable Speed Drive Sensor
Used to Vary Speed of Combustion Air Blower
Fully Characterized Curve Speed Curve
Advantage: Reduced Power Consumption & Reduced Noise!!!
Better Turndown
Asymmetric Speed Wheel w/ Inductive Sensor
Added Safety - Actual Motor Speed Monitored by Sensor
Added Safety - Sensor Verifies Motor Rotation
O2 Trim System
Continuous adjustment of fuel-to-air ratio
Adjustable O2 alarm level
Proven zirconium dioxide sensor
Self-calibrating sensor & self-test diagnostics
Stack-mounted sensor provides immediate detection of O2 changes in flue gas
Pro-active tuning loop minimizes lag in response time
O2 can be trimmed by air damper, VSD, or auxiliary
Ambient and flue gas temperature measurement for combustion efficiency calculation
ACS450 Commissioning Software
Burner statusDiagnostics
Trending and data logging Commissioning tool
Touchscreen Interface Lead/Lag SolutionsOne screen to control and monitor boiler operation, setpoints & process data
Real time burner status and operation data
Easy navigation buttons
Animated graphical representation of valve
and actuator positions
Auto/Manual setpoints entry
Hours run and startup counters
Feedwater control
Sweet Spot Tracker for optimum boiler room
efficiency
• Optional graphics: Oil temperature, gas/oil pressure and flow, feed water temperature and flow, steam flow, economizer inlet and
outlet temperatures
Introducing the LMV37
Accuracy
Affordability
Absolute Simplicity