5000 E Series3 phase MODULAR UPS Systems
50 - 800kVA Features:
Scalable modular architecture.
True on-line, double conversiontopology: VFI-SS-111
classification.Outputs from 50 - 800kVA/kW.
1.0 Output PF.
Excellent input characteristics: PF>.99;THDi
-
Typical Applications Include;■- Co location.■- Data-centres.■-
Disaster recovery data-centre.■- Telecommunication installations.■-
Healthcare.■- Industrial.■- Infrastructure projects.
Rated Capacity: 50-800kVA (1-16 power modules).
Rated Voltage: 380/400/415 Vac.
Rated Frequency: 50/60 Hz.
Type: Transformer-less, Online, double-conversion, modular.
Series Modular Uninterruptible Power System
SIELEnergy Systems
-
SIELEnergy Systems
Scalability
■ The 5000-E series offers the ability for system expansion to
coincide with increases in your load growth, thus negating the need
to install an oversized system on day 1.
The systems hot-swappable modular architecture supports
flexibleon site expansion for capacity and/or resilience as and
whenrequired.
>> All Hot-Swap Module Design
Reduced MTTR - High Availability.
In the unlikely event of a fault occurring modules can be
swapped on-line without risk to the critical load and without the
need to transfer to bypass.
Modules are individually switched off before removal from the
system. Swap out time is minimal, thus resulting in significantly
reduced MTTR. The true modular concept also offers significant
advantages in respect to maintainability and reduces the level of
spare part inventories compared to traditional systems.
Series Modular Uninterruptible Power System
-
■ When load levels allow, Intelligent hibernation can be enabled
and one or more modules will switch to a "standby" state to boost
load levels on active modules ensuring the system operates at it’s
optimum efficiency.
■ To ensure availability is maintained, at least one power
module serves as a redundant module and when load levels dictate,
hibernating module(s) are automatically reinstated.
Module
Module
Module
Module
Module
Module
Module
Module
High Operating Efficiency
■ The design configurations of traditional UPS Systems has in
the past resulted in the necessity to oversize the system at the
initial design stage to meet the expected future power demand, the
result being that these types of installations are often operated
at low load levels resulting in lower operating efficiencies.
■ The 5000 - E series UPS demonstrates an industry leading high
efficiency level at low load; 96% at 40% rated load and 95% at 20%
rated load resulting in significant energy & cooling cost
saving and overall reductions in your TCO.
■ Given 200 kW load and air conditioner with a COP of 3:1,
- 80, 183 kWh can be saved compared to traditional UPS(92%
efficiency)
- 257, 731 kWh can be saved compared to legacy UPS(86%
efficiency)
>> High Efficiency at Low Load Level
>> Intelligent Hibernation Design
■ When the quality of the mains supply permits, ECO mode can be
enabled which improves the overall efficiency to more than 99%
achieving even greater levels of energy savings.
■ In ECO mode, the load is powered by static bypass (the
allowable input tolerance range can be pre-set) and the inverter is
in "standby" state.
■ When the input supply exceeds the pre-set limits, the 5000-E
will immediately re-transfer to online mode operation ensuring the
connected load remains fully protected against disturbances in
double conversion mode.
>> Achieving 99% Efficiency in ECO mode
Efficiency
Series Modular Uninterruptible Power System
SIELEnergy Systems
-
■ High power density of up to 300kVA per cabinet, 50%footprint
saving.
■ Front accessible maintenance.
■ Back-to-wall installation (50-200kVA).
■ Top/bottom cable entry compatible.
>> Small Footprint and Easy Construction
■ Automatic switching between float charging and averagecharging
and temperature compensation.
■ Battery hibernation design to avoid long-term floatcharging,
which improves battery service life greatly.
■ Battery failure pre-alarm.
■ Flexible battery configuration: 32-50 batteries per
stringallow customers to remove a faulty battery instead
ofreplacing it.
>> Intelligent Battery Management, Extending Battery
Life-Span
■ THDi0.99 reduce the pollution to power grid and lower the
expense on power distribution componentsincluding cables, breakers,
etc.
■ Power walk-in technology boost the ratio of UPS capacity to D.
G. capacity to 1:1.1.
>> Reduced Costs On Power Distribution System
Series Modular Uninterruptible Power System
SIELEnergy Systems
-
φ
■ The 5000-E series is optimised to meet the demands of today's
high PF loads.
Systems have an output power factor of 1. and are fully
compatible for supplying ‘Capacitive’ or ‘Inductive’ loads having a
PF of >0.5 without further de-rating.
>> Load Compatibility
■ No de-rating at 400 to ensure power continuity.
■ Conformal coating on PCB, improving adaptability to dustyor
salty spray environment.
>> High Environment Adaptability
■ 138-485 Vac wide input voltage range to minimize batteryuse:
485-305Vac for 100% load; 305-138 Vac for 100%-40% load (de-rating
linearly).
■ 6 kV/5 kA surge protection.
>> High Grid Adaptability
■ Redundant design for energy control unit &
communicationbuses to eliminate single points of failure.
■ Fault-tolerant ventilation system:.
>> True Redundant Design
Series Modular Uninterruptible Power System
SIELEnergy Systems
-
Value & Features
High availability, warning and troubleshooting
■ Pre warning of faults and risks improves IDC availability.
■ Rapid faults location, virtual inspection.
Smart interaction, energy saving
■ Dynamic PUE management.
■ Optimization of power and cooling services.
Rapid deployment, one -button launching
■ Pre-configured software and parameters, one-button launch.
■ Parameters of AC and UPS loading.
Easy visualization maintenance in 3D view
■ The 3D design tool realizes 3D visual maintenance.
■ Dynamic 3D display of site temperature, eliminating hot
spots.
■ iManager NetEco 1000U can run on the Windows operating system
and can be accessed through a web browser. The iManagerNetEco 1000U
enables you to monitor the key performance indicators (KPIs) and
alarms of the UPSs in real time. In addition, itenables you to
remotely control and manage the UPS's. This increases the
centralized management and remote operation andmaintenance
capabilities for the UPSs. NetEco 1000U supports connection through
USB Data lines, RS232 cable, or network cable.
>> NetEco 1000U Introduction
■ NetEco is a new generation data centre management
System. It manages the real-time data and status of datacentre
infrastructures, including power, environment, video,and door
status and generates alarms if fault arise.
■ NetEco displays data centre layouts and data reports
forcustomers to easily query equipment status, and provides
astandard platform to apply to all data centre solutions dueto its
flexible configuration, smooth capacity expansion, andhierarchical
management.
>> NetEco 6000 Introduction
Series Modular Uninterruptible Power System
SIELEnergy Systems
-
50kVA power module - 3U
Static bypass module
Energy control module
Monitoring unit with built-in SNMP and RS485
Mechanical frame
Maintenance bypass switch
7-inch Liquid Crystal Display (LCD)
Dust filter.
Series Modular Uninterruptible Power System
SIELEnergy Systems
Units shown configured as FC version
-
>> Dry Contact CardThe dry contact card allows the UPS to
control and monitor theswitch state of BCB box and implement the
EPO.
>> Power ModuleThe Power module with rated capacity of 50
kVA/kW is based on TrueOn-Line Double Conversion topology.
Its dimensions are 130 mm (H) x 442 mm (W)x 620 mm (D).
>> Bypass Module
The bypass module provides an automatic and
instantaneoustransfer of the load to mains supply in the event of
an overloador internal fault occurring.
The bypass module of the 5000-E series feature a fully
ratedswitch to suit the frame capacity.
>> Energy Control Module
The ECM supports intra-rack parallel CAN communication and
inter-rackparallel CAN communication. The intra-rack load-share
control andinter-rack load-share control are isolated at the ECM to
achieve betterexpandability.
>> iBox/iBat
Supports wireless transmission of individual battery block
voltage,resistance (impedance) and temperature.
SIELEnergy Systems
-
Antiseismic kit Reinforces the cabinet so that the cabinet meets
the requirements of 9 degree seismic fortification intensity.
IP21 component Prevents water from dropping into the cabinet,
protecting the cabinet to IP21.
Top outlet kit If you need to install the cabinet against the
wall, install a top outlet kit to meet heat dissipation
requirements.It's suitable for 50-200kVA.
ECM extended subrack Install this subrack when the UPS5000-E is
equipped with a back-feed protection card and dry contact extended
card.
Top entry cabinetInstall a top entry cabinet to meet the
requirements for routing cables from the top of the UPS5000-E
cabinet.It is suitable for 200-300kVA.
Ambient temperature andhumidity sensor
Battery temperature sensor can detect the battery temperature
and provide reference for temperaturecompensation when
float-charging.
Battery temperature sensor Feedbacks real-time temperature and
humidity data to dynamic environment monitoring system.
>> Dry contact extended card (Optional)The dry contact
extended card provides five relay dry contact outputsand five
signal input ports. The card implements additional alarm andcontrol
functions to meet customer requirements.
>> Back-Feed Protection Card (Optional)The back-feed
protection card sends signals to trigger alarm signalsor quickly
disconnect the feedback loop
>> Battery Ground Fault Detector (Optional)The battery
ground fault detector detects battery ground fault and sendsalarm
signals when the ground leakage current exceeds the
thresholdvalue.
>> Battery Monitoring Unit (Optional)Battery monitoring
unit supports detection about the voltages, chargeand discharge
currents, and temperatures of 24 batteries with a ratedvoltage of
2–12 V DC.
Series Modular Uninterruptible Power System
SIELEnergy Systems
-
MainsInput
Input Wiring 3Ph+N+PE
Rated Voltage 380/400/415Vac
Voltage Range 138-485 Vac (305-485 Vac for 100% load; 138-305
Vac for 40%-100% load)
Input Frequency 40-70 Hz
Total HarmonicDistortion THDi
-
SIEL Energy Systems LtdSIEL House, Unit E Draycott Business
ParkCamGLoucestershire. GL11 5DQ
Telephone: 0845 130 6118
mail:[email protected]
www.sielenergy.co.uk
SIELEnergy Systems