The Neptune series is a family of new generation monitoring systems for continuous monitoring of patient's vital signs
parameters.
They are equipped with a new software & hardware platform responding to all clinica! needs.
Neptune monitors are designed to have a more flexibility of
use in different hospital wards: Recovery Rooms. Intensive Care Units, Neonatology, Emergency Units, Operating Rooms.
Vital Signs Parameters that can be continuously monitored during patient therapy are:
Basic Parameters:
•HR• SPO2
• NIBP
• 2 TEMP• ECG/RESP 3-5 LEADS• ST SEG MENT & ARRHYTHMIA ANALYSIS
Optional Parameters:
• 2 IBP
•ECG-RESP 12 LEADS
• CO (CARDIAC OUTPUT)•CO2
• MULTI-GAS• MASI MO RAINBOW PREDISPOSITION
• CEREBRAL STATE MONITORING (INDEX OF CEREBRAL STATE FOR THE MEASUREMENT OF ANAESTHESIA DEPTH - CSI)
�
ISA Sidestream Multi-gas Module
Advantages tor clinicians:
IRMA Mainstream CO2 Module
AII Monitors of Neptune Series are equipped, as standard feature, of a software provision for additional functions like Sidestream (ISA) and Mainstream ORMA) Multi-Gas and CO2 technologies.
This exclusive technology permit to the clinicians to use the modules on different monitors of Neptune series. This feature grants a significant costs saving and an absolute flexibility of use.
www.siare.it
12" touch screen
colour LED display
AII Neptune monitors are equipped with A wide range of optional accesso a Masimo SET technology as a standard. complete the monitors.
'JE
■■Hq T l
/ 78 38,3
03) i;, 347 P• al •
0 0 (ol -35
•c
lS to
sn
D-16 CENTRAL MONITORING STATION
- High resolution double colour TFT LCD touch screen for data displaying.
- Up to 64 waveforms displaying in real time for 16 bedsides at the same time
- Displaying of Sp02, RESP parameters and ECG, C02, 2 IBP waveforms
- Possibility to select waveforms and parameters
- Different configurations of main screen
- Acoustic and visual alarms
- Up to 96 hours recording, trends and reviews
- Up to 720 alarm event and reviews
- Up to 1000 NIBP measurements
- Data backup
- Printer (optional)
-
15" colour display
I
-
NEPTUNE 12" Touch Screen Waveforms
Numeric Paramelors
Operation Method
Leads
Dynamic Range Lead Off Current Gain Calibration Filters
CMRR Internal Noise Input Impedance OAS Detection
Heart Rate Range
Accuracy Tall T-Wave Pacer Detection/Rejection
Protection Standards t.t;1,1:&1:1Ytlt-t·!�t•1N1½ Type
Learning
Method
Memory
Display tesolution Measurement Range Alarm Range Features
Update period
i - .
• � -1 • .s -
NEPTUNE 12" Touch Screen Code A56.NT NEPTUNE 15" Code A56.NEPT15
For additional accessories please refer to the price list in force
LED COLOR 800 '600, 12" ECG, SP02, IBPI, IBP2, RESP/GAS, EEG (Freezable). C.O. HR, PVCs, ST, SP02, PR, NIBP
(SYS, DIA, MAP), IBP1(SYS, DIA, MAP), IBP2 (SYS, DIA, MAPI, RR, TI, T2, OT, EtCo2, f;Co2, AWRR, EtN20, f;N20, Et02, f;o2, EtAA, f;AA, CSVBFI, SS%, EMG¾, SOI%, C.O, Alatm Limits. Membrane/Keys and rotary knob, no Touch Screen
Selectable 3 , 5 (or 10 Wires optional) �or 3 wire: I, II, Ill For 5 wire : I, II, Ill, V, aVR. aVF, aVL For 10 wire : I. II, Ill, V, aVR. aVF, aVL , C2, C3, C4, CS, C6 :: 5 mV < 90 nA 4, 2, 1, 1/2, 1/4, Auto
1mV, 0.5 sec "MONITOR"( 0.5, 24 Hz I ... NORMAL"( 0.5 - 40 Hz) "EXTENDED"( 0.05-100 Hz( >98dB< 30 µV RTI >5 M Duration :40 to 120 msee Amplitude :0.25 to 5 mV for
Adult/Pediatric 0.2 lo 5 mV for Neonate
15 • 300 8PM for adult/pediatric 15 • 350 8PM for neonate :1% ot 2 8PM Reject up to 1.2 mV Amp. Duration : 0.1 • 2 msec Amp: :t2 lo :t 700 mV !without over/undershoot) Reject from heart rate counter Re-insert into ECG to display on screen Ineffective pace rejection: HR:O, Pace: 60 HR:60. Pace:60 HR:30, Pace:80 Beside rejection of atrial paces preceed ventricular paces by 150 or 250 ms Defibrillator and Eleclrosur-gery ANSVAAMI EC- 13, EN 60601-2-27
ASYS, VFIB, VTAC, RUN, AIVR, COUPLET. BIGEMINY, TRIGEMINY, TACHY, BRADY, AFIB, PAUS, FREQUENT PVCs Rapid Learning: only 20 seconds required for recognition of dominanl rhythm. Real time arrhyrhmia deteclion with innovative feature. Capability of storing the latest 150 ARR event. {waveform and Parameters)
0.01 mV -2mv to +2mv -2mv to +2mv User Adjustable lsoelectric and ST point trending of ST values 5 Sec.
TECHNICAL DATA
Measurement method Measurement mode Measurement lime
Measurement Range
Pressure Transducer accuracy Initial Inflation Target
Oscillometric ManuaVAutomatic/Stat 20-25 sec (excluding cuff pmssurization time) Aduh: SYS 30 - 255 mmHg
DIA 15 - 220 mmHg MAP 20 - 235 mmHg
Neonate: SYS 30-. 135 mmHg DIA 15 - 110 mmHg MAP 20 - 125 mmHg
Pediatric: SYS 30-. 240 mmHg DIA 15 ... 220 mmHg MAP 20 ~ 230 mmHg
.!:3 mmHg full range Adufl 150 mmHg, Pedialric 140mmHg, Neonate 85 mmHg
Overall Sys1em Efficacy Meet ANSI/AAMl SP-10/2002 Memory 500 Records
Method 2 Wave length pulse wave type Range Sp02 0- 100 %
SpMet O -99.9 % SpCO 0-99 % SpHb O - 25.0 g/dL SpOC O - 35.0 ml/dl
During no motion condi1ions:
During motion condi1ions:
During low petfusion condi1ions:
Probe Type Range Accuracy
Method Base Resista nee Dynamic Range Breath Rate Range Accuracy
Channel Measurement Range
Pressure Filter Press Sensor Sensiti-Yity Press Senso, Impedance Resolution Accuracy
PR 25 -240 bpm PI 0-20.0 % PVI 0-100 %
Adult/Pediatric: ,2%1SP02 70 -100%1 Neonate: .!:3% (SP02 70 - 100%) Ad uh/Pediatric/Neonate: e3%(SP02 70 - 100%) Ad ult/Pediattic/Neonate: ,2%(SP02 70 - 100%1
YSI 400 Compatible o - so ·c , 0.2 •c
Impedance 250 ·1250 Ohm 0.2- 2 Ohm 0 - 253 BrPM
•2'% or 2 BrPM
2 {Up to 4) SYS 50 ~ 300 mmHg DIA 50 .. 300 mmHg MAP 50 - 300 mmHg 8Hlz, 16Hz, 22Hz selectable 5 �v /V /mmHg 300 • 2500 Ohm 1 r'nmHg 2 % or 2mmHg (oach one is greater) willhout transducer
IM115,=1fflt.f.'l:f-i1;l:iM&[•lif1:-)�f.iPower suppyl 4.5-5.5 VDC, max 1.4W Method Infra red absorption Measuring mode Mains1ream IRMA Harmful Liquid Proof Degree IPX1 Et and Fi Parameters Fi and ET are displayed after one breath and have a continually updated breath average IRMA C02 C02. C02 waveform IRMA AX+ C02, N20, Anaesthesia Agenl
(HAL, ISO, ENF, SEV, DES), 5 selectable waveform. Automatic identification, MAC
l!.l11!i1#€t}1fil•l!i1;1:1.◄,,,l•lii❖U1'Power supply 4.5-5.5 VDC,
Method Measuring mode El and Fi Parame1ers Fi and ET are displayed after one breath and have a continually updated breath average ISAC02 ISAOR+
ISA AX+
EEG sensitivity Noise CMRR Input impedance Sample rate
CSI and update EMG
SS%
Digital output
Wireless range Display size Alarms Artifact rejection Sensor impedance range
Method Range Resolution Reproducibility
Model Printing Speed Paper
Sources
Alarm On/Off Alert
Sources
Trend Time Save Trend Time Interval Resolution IW41JfJl11tl41,Network
Connection
ISA C02: <1.4 W {normal op.). <1.8 W (peak@ 5 VOCI ISA AX+: <1.6 W !normal op.), <2.0 W (peak@ 5 VOC) ISA OR+: <2.0 W !normal op.), <2.4 W (peak@ 5 VOCI lnfrared absorption Sidestream
C02, C02 waveform C02,02, N20, Anaesthesia Agent (HAL, ISO, ENF, SEV, DES), 5 selectable waveform, Automatic agent identification, MAC C02, N20. Anaesthesia Agent (HAL, ISO, ENF, SEV, DESJ, 5 selectable waveform, Automatic agen1 identification, MAC
o400µV <21-1Vp-p <0.41..V RMS, 1-250 Hz ,140dB >50M 2000 samples/sec (14 bits equivalent) 0· 100. Filter 6-42Hz, 1 so-<:. update 0-100 logarithmic. Filter 75-85 Hz, 1 sec. update o� 100%. Filter 242 Hz, 1 sec. update Wireless to CSM card in monitor USM 2.4GHz) Up 10 10 meters 1.3• x 0.7" H1gh/low with user selectable limit Automatic 0-10k0hm / measurement current o.o,..,A
Right Heart Thetmodilution 0.5 -18 Vmin 0.011/min ,3%
Thermal Prinlor 6, 12.S. 25, 50 mm/sec 58mm by 100 foot roll
Error messages , All other parameter limits Selectable for all parameters Blinking on Display, Volume Selectable Audio Alarms, Light indicator
HR, PVCs, ST, AFIB, SP02, RR, T1, T2, IBPI (SYS, DIA, MAP), IBP2 (SYS, DIA, MAP), IBP3 ISYS, DIA, MAP!, IBP4 (SYS, DIA, MAP), EtCo2. FiCo2, AWRR (sidestream. mainstream), EtN20, FiN20. Et02, Fi02, EtAA, FIAA USO, DES, ENF, HAL, SEV) 96 Hours 1'5, 30. 45 Min, 1, 2 and 4 Hours 1 sec
Reliable TCP/IP Protocol Ethernet LAN with RJ45 Interface VGA connector. External alarm, Wirod remote conttol for CSI module only
Distributed by:
EN GINEE RIN G
INTERNATIONAL GROUP s.r.l.
Via G. Pastore, 18 - Crespellano 40053 Valsamoggia (BO) Italy
Phone: +39 051 969802 (r.a.) - Fax: +39 051 969366 General e-mail: [email protected] - Internet: www.siare.it
Slt«ERT
lc�T
� ���,;;)','..:';,,, CE 0476
0 M g 0 ::::, Cl
'SJ'
N er: LU co 0 tu
0 C: 0 u a, C: 0
-;;;
-�er:
a, (,,)
·gC: �0 £-�a, 0) C: ro
,s::, (,,)
,8
g'E::, CJ)
ro Cl
SPO2 (MASIMO)
IBP (OPTIONAL)
CSM OPTIONAL (CSI MODULE)
RECORDER (OPTIONAL)