Showermax update and new Hall A SAMs Dustin McNulty Idaho State University [email protected] April 30, 2016
33

Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

Jul 30, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

Showermax update and new Hall ASAMs

Dustin McNultyIdaho State University

[email protected]

April 30, 2016

Page 2: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Showermax update and new Hall A SAMs

Outline• Showermax Detector Update

–Design: alternating 4-piece quartz/tungsten stack–Optical G4 sims: bench-marked quartz properties–Engineered prototype design

• Hall A Small Angle Monitors SAMs (f.k.a. Lumis)–Motivation and re-design–Prototype and testbeam results–Final design and installation–Simulated Rates for parasitic tests

• Summary and Plans

Dustin McNulty Showermax update and new Hall A SAMs 1

Page 3: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Showermax Detector

• Provides additional measurement of e-e ring flux

• Weights flux by energy =⇒ less sensitive to lowenergy/low light bkgds

Dustin McNulty Showermax update and new Hall A SAMs 2

Page 4: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Showermax Detector Ring

Dustin McNulty Showermax update and new Hall A SAMs 3

Page 5: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Showermax Detector (10 piece stack)

• 10 pieces quartz (each 5.0mm thick): 0.41 X0

• 10 pieces tungsten (each 2.4mm thick): 6.8 X0

• 25 cm light guide 3” PMT. Note:Uniform sampling, trapez. Q

Dustin McNulty Showermax update and new Hall A SAMs 4

Page 6: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Showermax Detector (4 piece stack)

• 4 pieces quartz (each 12.5mm thick): 0.41 X0

• 4 pieces tungsten (each 6mm thick): 6.8 X0

• 25 cm LG; 3” PMT. Note: center sampling, rectangular Q, new QE

Dustin McNulty Showermax update and new Hall A SAMs 5

Page 7: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Optimal funnel-mirror angle study

Dustin McNulty Showermax update and new Hall A SAMs 6

Page 8: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Optimal funnel-mirror angle

• Peak light exits quartz at -46.0o and 46.5o for 8 GeV and closer to45o for lower energy (that is ∼normal to bevelled face)

• Means our original light guide design is near optimal

Dustin McNulty Showermax update and new Hall A SAMs 7

Page 9: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

New Monte Carlo results: Using benchmarkedquartz properties and simple 60% reflectivity

• Original Light guide geometry: designed for ±45o light output

Dustin McNulty Showermax update and new Hall A SAMs 8

Page 10: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Precise funnel-mirror angle is crucial

• Experimental LG geometry: designed for ±53o light output

• Only 4o angle difference (and elongated) – gives 60% less PEsDustin McNulty Showermax update and new Hall A SAMs 9

Page 11: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Costing: Showermax Quartz (4 piece stack)

Spectrosil 2000: One 45 degree face, all surfaces polished to ≤ 20 A, nosmall edge-bevels. OPEN–$1043/piece ($32k), CLOSED–$1265/piece($39k), TRANSITION–$1080/piece ($67k); total quartz cost is $138k

Dustin McNulty Showermax update and new Hall A SAMs 10

Page 12: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Costing: Showermax Tungsten (4 piece stack)

99.95% purity; ±0.005” tolerances. Received quote from company”Marketech”: OPEN–$484/piece ($13.6k), CLOSED–$647/piece ($18.1k)TRANSITION–$511/piece ($28.6k); total tungsten cost is $60.2k

Dustin McNulty Showermax update and new Hall A SAMs 11

Page 13: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Showermax prototype CAD

Dustin McNulty Showermax update and new Hall A SAMs 12

Page 14: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Showermax Summary and Plans

• Quartz optical properties benchmarked: tuned G4 Glisurepolish parameter (0.981) using PREX detector testbeam data

• Mirror optical properties under investigation (see next talk);MC currently uses uniform 60% reflectivity for all λ and angles

• Baseline design gives strong energy dep. light yields (∼20% res)

• Will continue to study and optimize baseline design:thicknesses of quartz/tungsten pieces and LG geometry

• $45k line item in MOLLER pre-R&D proposal to build threeShowermax prototypes–one for each phi region

• Starting to plan for the prototyping process this summer andSLAC testbeam next year

Dustin McNulty Showermax update and new Hall A SAMs 13

Page 15: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

SAMs (downstream lumis) for MOLLER

• Detect charged particle flux at extreme forward angles• Important diagnostic of target density fluctuations

and overall noise floor• Can use parasitic tests for upcoming PREX as a

learning opportunity for MOLLER SAM developmentDustin McNulty Showermax update and new Hall A SAMs 14

Page 16: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Motivations for SAM’s

• Need them for their high sensitivityto helicity-correlated beam parameters

– Detect charged particle flux atextreme forward angles

– Very high rates and thus narrowpulse-pair widths – powerfuldiagnostic tool

• Provides measure of overall electronic noise floor in the hall

• In theory, should have very low/no PV asymmetry and can serveas null asymmetry monitor

• Symmetric 8 piece design helps disentangle beam position andangle HCBP’s while 8 SAM sum is insensitive

• Could provide important tests of regression procedures

Dustin McNulty Showermax update and new Hall A SAMs 15

Page 17: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Old Hall A Luminosity Monitor

• Conceptual Design 2002–Riad Suleiman; refurbished in 2008

• 8 quartz Cherenkov detectors with air-core light guides placedsymmetrically around beam line 7m downstream of pivot

• Used 6.0×2.0×1.0 cm3 quartz placed 4.5 cm from beam center⇒ 0.3 - 0.8 deg polar angle acceptance

Dustin McNulty Showermax update and new Hall A SAMs 16

Page 18: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Luminosity Monitor Re-design (SAMs)

• Incorporate Qweak’s downstream Lumi experience:–Use pre-radiator (maybe) and ”unity gain” PMT–Use radially smaller, but thicker quartz–May achieve desired linearity at anticipated photocathodecurrents, but running unity gain mode may guarantee it

–Use TRIUMF preAmps at SAM for signal cond. and gain

• Work within constraints of existing beampipe insertion tubes!

Dustin McNulty Showermax update and new Hall A SAMs 17

Page 19: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Prototype SAM for MAMI Testbeam (May 2015)

• Using 2” Hamamatsu R375 (multi-alkali, 10 stage) +E1435-02MOD unity gain base housed in mu-metal shield

• Anolux Miro-27 light guide; N2 purge/flush

• Spectrosil 2000 quartz: 3.0×2.0×1.0 cm3 (prototype)

• Tungsten: 2.0×2.0×1.0/1.5 cm3; Aluminum and Delrin frame

Dustin McNulty Showermax update and new Hall A SAMs 18

Page 20: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

MAMI Testbeam (SAM Tests)

855MeV, 5kHz

• Last testbeam: May 29 - June 1, 2015: MOLLER, PREX/CREX

• Half a shift for Lumi prototype tests:–Different tungsten thicknesses: 0, 10, and 15 mm–Different lightguide lengths: 41 and 35 cm–With and without N2 purge

Dustin McNulty Showermax update and new Hall A SAMs 19

Page 21: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Prototype SAM Testbeam ResultsRun # LG Tungsten with N2 peak PEs (gain) peak PEs (sim)

652 41cm 0mm No 1.3 5643 41cm 10mm No 8.0 15706 41cm 15mm No 9.8 13

712 41cm 0mm Yes 2.0 not gen.

716 35cm 0mm Yes 2.2 not gen.

713 35cm 10mm No 13 20

• For no tungsten, adding N2 (compare runs 652 and 712) increasesPEs from 1.3 to 2.0 (+50%)

• For no tungsten, shrink LG by 6cm (compare runs 712 and 716)increases PEs from 2.0 to 2.2 (+10%)

• For 10mm tungsten, shrink LG by 6cm (compare runs 643 and 713)increases PEs from 8.0 to 13 (+60%)

• For 41cm LG, increase tungsten from 10mm to 15mm (compare runs643 and 706) increases PEs from 8.0 to 9.8 (+23%)

Dustin McNulty Showermax update and new Hall A SAMs 20

Page 22: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Final SAM Design

(will calibrate PE yield at MAMI this May)

Improvements over prototype:• Increased thickness of quartz: 33 mm × 20 mm × 13 mm

• Shortened light guide and made it taller and slightly wider;also changed its one-bounce mirror by 4o based on optical sims

• Includes custom CF flange mounting adapters – for easierde-install/re-install and alignment tuning

• Includes gas exhaust ports and quartz securing mechanism

• Question of tungsten pre radiator not yet decidedDustin McNulty Showermax update and new Hall A SAMs 21

Page 23: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

SAM Assembly (Nov 2015)

Dustin McNulty Showermax update and new Hall A SAMs 22

Page 24: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

SAM Installation (Dec 2015)

Dustin McNulty Showermax update and new Hall A SAMs 23

Page 25: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

SAM Rate Simulations

• New stand-alone G4 simulation for estimating SAM rates

• Simulation uses BERT phys. library and handles all processes

• Tallies scattered primary electrons, as well as any secondariesthat pass through annulus centered on the beamline, 7 metersdownstream of the target

Dustin McNulty Showermax update and new Hall A SAMs 24

Page 26: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Simulated SAM Rates for DVCS Parasitic Tests

Results from new G4 SAM simulation run for 15 cm LH2 target and 11GeV beam with 2 by 2 mm2 raster: Rate per SAM per µA is ∼80MHz

(Note that most of the rate is coming from 1 GeV or less electrons)Dustin McNulty Showermax update and new Hall A SAMs 25

Page 27: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Simulated SAM Rates for 167mg Carbon at 9GeV

• Results for 9 GeV pin-point electron beam on 167 mg C target

• 108 beam electrons thrown; results are scaled to give events/uA

• SAM polar angle accept. estimated to be from 0.4 to 0.6 degree

• Rates calc using sim results and estimated azimuthal accept.

• ∼260 MHz/µA/SAM with over 75% of rate from 1 GeV or less

Dustin McNulty Showermax update and new Hall A SAMs 26

Page 28: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Summary and Plans for SAMs

• New Hall A SAMs constructed and installed

• Present configuration gives flexibility for future parasitic tests

• Will take spare SAM to Mainz for PE yield calibration,pre-radiator, and LG study

• Preliminary LG reflectivity measurements in hand; will useMAMI testbeam results to benchmark mirror properties in MC

• Will likely replace SAM LGs depending on testbeam results;may replace Miro-silver-27 with Anolux-UVS or Anolux-I

Dustin McNulty Showermax update and new Hall A SAMs 27

Page 29: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Extra Slides

Dustin McNulty Showermax update and new Hall A SAMs 28

Page 30: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Lumi v1 Lightguide Design (Prototype SAM)

• Constraints of existing beam pipe insertion tubes...light guideis long and narrow

• Optimized? one-bounce design

Dustin McNulty Showermax update and new Hall A SAMs 29

Page 31: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Prototype SAM Optical Simulations

• G4 optical simulations:–lumi v1: 3.0×2.0×1.0 cm3, 41cm one-bounce lightguide (air)–Used 1GeV electrons, centered on quartz with 90o incidence–Varied tungsten thickness from 0 to 20mm

Dustin McNulty Showermax update and new Hall A SAMs 30

Page 32: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

Lumi R&D Summary• Results are preliminary; analysis and simulation work ongoing

• Narrow beampipe insertion tubes significantly restrict lightcollection at PMT

• Qualitative agreement between initial simulations and test beamdata. But why peak PE values have ∼large disagreement?

–Incident MAMI beam angle was 86o, not 90o

–LG reflectivity coeffs. in MC need verification/improvement–Bending LG into proper shape is not trivial...

• Can use this data (combined with other prototype detector tests) tohelp benchmark optical MC

• Pre-radiator significantly increases PE yield by factor of 5 or 6

• Flushing with dry N2 increased signal size by 50% (whoa!)

• Sum of quartz and tungsten thicknesses must be ≤ 2.3cm – so ifquartz is 1cm, then W can be upto 1.3cm...What is bestconfiguration?

Dustin McNulty Showermax update and new Hall A SAMs 31

Page 33: Showermax update and new Hall A SAMsmcnudust/...2016Apr30_detTalk.pdf · 4/30/2016  · angle HCBP’s while 8 SAM sum is insensitive •Could provide important tests of regression

MOLLER Collaboration Jefferson Lab Hall A'

&

$

%

SAM configuration (Jan 2016)

ADC 29

IN ch1 OUT

IN ch2 OUT

IN ch1 OUT

IN ch2 OUT

IN ch1 OUT

IN ch2 OUT

IN ch1 OUT

IN ch2 OUT

KDPB002

KDPB001

R7723

SAM1

SAM2

R7723

SAM3

R375

4

SAM5

R7723

R375

SAM6

R7723

SAM7

R375

SAM8

SAM

(50 , 82 pF/m)

Long, Fat TwinaxRG−58 SAM1

SAM2

SAM6

SAM3

SAM7

SAM4

SAM8

SAM5

ConvertersRG−58 (1−2m)

(0.3m)

(50m)

Converters

ch1

ch3

ch4

ch5

ch6

ch7

ch8

ch2

(LUMI009)

(LUMI007)

(LUMI002)

(LUMI006)

vQwk

ch0

ch1

ch2

ch4

ch5

ch6

ch7

ch3

SAM1

SAM2

SAM3

SAM4

SAM5

SAM6

SAM7

SAM8

slot4 (rpi7)HV

Twinax to BNC

RHRS Hut

(non−inverting)

Twinax to BNC

BNC to BNC

BNC to BNC

(pass through) (pass through)

Kent’s 5VPowerSupply

Mark’s 5VPowerSupply

(all non−inv)

Twinax to BNC

Twinax to BNC

BNC to BNC

BNC to BNC

(LU

MI005)

(1m)

SAM1

SAM2

SAM3

SAM4

SAM5

SAM6

SAM7

SAM8

(10)

(LUMI003)

(LUMI013)

(LUMI004)

(LUMI010)

(LUMI001)

(LUMI002)

(LUMI003)

(LUMI004)

(LUMI005)

(LUMI006)

(LUMI007)

(LUMI008)

Ω

100k

50M

36k

36k

Ω

Ω

Ω

Ω

unity gain

high gain

high gain

high gain

unity gain

high gain

high gain

R375

high gain

lumi−style rev.2H8

KDPB004

Dustin McNulty Showermax update and new Hall A SAMs 32