Structural Health Monitoring in WSNs by the Embedded Goertzel Algorithm Maurizio Bocca , Janne Toivola, Lasse M. Eriksson, JaakkoHollmen, Heikki Koivo Department of Automation and Systems Technology Aalto University School of Electrical Engineering, Helsinki, Finland www.wsn.tkk.fi
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Structural Health Monitoringin WSNs by the
Embedded Goertzel Algorithm
Maurizio Bocca, Janne Toivola, Lasse M. Eriksson,JaakkoHollmen, Heikki Koivo
Department of Automation and Systems Technology
Aalto University School of Electrical Engineering, Helsinki, Finlandwww.wsn.tkk.fi
1
Looking back at SHM
ICCPS 2011, Chicago, IL, USA, 14.4.2011
AIM: accurate diagnosis of the health of civil infrastructures from data collected by sensors
Brooklyn Bridge, NYCAfrican
Elephant
Few Facts about Finland
• It is extremely difficult to retrieve elephants…
• Extremely cold climate
Very rigid temperatures
Lots of snow and ice
• 187 888 lakes… 14 000 (approx.) public roads bridges
• 150-200 new bridges built every year
• Most of the bridges built in the 60’s and 70’s: Originally not engineered for the current volume and type of traffic
Approaching the critical “50-years maintenance check”
2ICCPS 2011, Chicago, IL, USA, 14.4.2011
The 4 levels of SHM
ICCPS 2011, Chicago, IL, USA, 14.4.2011
Damage detection
Damage localization
Damage quantification
Assessment of the remaining lifetime of the structure
COMPLEXITY
PATIENT:the monitored infrastructure
DOCTOR:the structural engineer
3
Outline of the Talk
4ICCPS 2011, Chicago, IL, USA, 14.4.2011
Goertzel algorithm (GA) and Transmissibility Functions (TFs)
WSN architecture
Experimental evaluation
• Published in 1958. Classic application: DTMF
• Compared to the FFT, the GA:
allows to efficiently calculate the amplitude of the frequency spectrum at specific bins (frequencies of interests, fi)
worksiteratively: no need to store the accelerationsignals in RAM orFlashmemory for off-lineprocessing
the number of collected samples (N) does not need to be a number power of 2
Why the GA for SHM? 1/2
5ICCPS 2011, Chicago, IL, USA, 14.4.2011
GA computationssample acquisition
samplingSTART
t
samplingEND
• Structuraldamagesmodify the frequencyspectrums of the accelerationsignalscollectedby the nodes
Why the GA for SHM? 2/2
6ICCPS 2011, Chicago, IL, USA, 14.4.2011
GA: Concept&Parameters
• The GA implements a 2nd-order IIR filtercentered at each frequency of interest:
• 3 keyparameters (set by the end-user):
Samplingfrequency(fs)
Distance (db) betweentwoconsecutivebins on the frequencyaxis(resolutionr = 1/db)
Vector of frequencies of interest (fi)
7ICCPS 2011, Chicago, IL, USA, 14.4.2011
12
1 2
1
1 2cos 2
i
s
i
fZ
f
f
i
s
eH Z
fZ Z
f
From the Goertzel Algorithm...
• Before the sampling:
Number of samples (N) to be collected to obtain the fixed resolution (r = 1/db)
Bins (k) corresponding to the selected frequencies of interest (fi)
Coefficients (c) used in the GA iterations
• During the sampling:
• At the end of the sampling:
8ICCPS 2011, Chicago, IL, USA, 14.4.2011
s
b
fN
d
0.5 i
s
N fk
f
2cos 2k
cN
0 1 2
2 1
1 0
iq c q q s
q q
q q
si: last collected sample
q1 and q2 store the results of thetwo previous iterations
2 2 2
1 2 1 2i i i ii iX N q q q q c
Xi: squared magnitude of the spectrum
...to Transmissibility Functions
• Transmissibility: the result of the interference of vibrations propating and reflecting along the structure
WOODEN TRUSS STRUCTURE: 420 cm long, 65 cm wide, 34 cm high, 44 kg
D1, D2, D3, D4: 500 g weight
sensor node
Electro-Dynamic Shaker
Damaged Cross Bar
D5: 27.6% stiffness reduction
D6: 55.2% stiffness reduction
Random noise excitation
Selection of the Critical Frequencies
14ICCPS 2011, Chicago, IL, USA, 14.4.2011
[32-35] Hz
[32-35] Hz
[27-30] Hz
DAMAGESIGNATURE
ExperimentalValidation (D1)
15ICCPS 2011, Chicago, IL, USA, 14.4.2011
ExperimentalValidation (D2)
16ICCPS 2011, Chicago, IL, USA, 14.4.2011
ExperimentalValidation (D3)
17ICCPS 2011, Chicago, IL, USA, 14.4.2011
ExperimentalValidation (D4)
18ICCPS 2011, Chicago, IL, USA, 14.4.2011
ExperimentalValidation (D5 and D6)
19ICCPS 2011, Chicago, IL, USA, 14.4.2011
D5: 27.6% stiffness reduction
D6: 55.2% stiffness reduction
GA vs Off-Line Modal Analysis (1/3)
• Modal analysis: study of the dynamic properties of structures under vibrational excitation
• Centralized off-line data analysis for identifying natural frequencies, mode shapes and damping ratios
20ICCPS 2011, Chicago, IL, USA, 14.4.2011
M. Bocca, A. Mahmood, L.M. Eriksson, J. Kullaa, and R. Jäntti, A Synchronized Wireless Sensor Network for Experimental Modal Analysis in Structural Health Monitoring, Computer-Aided Civil and Infrastructure Engineering, 2011.