Top Banner
Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY & DEPT. OF APPLIED MATHEMATICS AND STATISTICS, STONY BROOK UNIVERSITY 23 September 2011
14

Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

Jan 12, 2016

Download

Documents

Molly Day
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

Sharp Interface Tracking in Rotating Microflows of Solvent Extraction

Hyunkyung Lim, Valmor de Almeida, and James Glimm

OAK RIDGE NATIONAL LABORATORY&DEPT. OF APPLIED MATHEMATICS AND STATISTICS, STONY BROOK UNIVERSITY

23 September 2011

Page 2: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

Fluid properties for the test problem

We are running a case with realistic physical properties.

Aqueous phase (this is essentially an aqueous nitric acid solution)

mass density: 1.03 g/cm3 viscosity: 1.02 10-3 kg/(m s)

Organic phase (this is a diluted tri-butyl-phosphate in dodecane) mass density: 0.811 g/cm3 viscosity: 1.60 10-3 kg/(m s)

Interfacial tension can be varied from 10 to 20 mN/m

Page 3: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

The code problems and updates Higher order normal and curvature calculation: Very large curvature happened in some cases. The problem should be cured with a limiter.

Wrong phase problem wrong default phase fill the correct phase using previous time step phase (more robust) Automatic global reconstruction Only a few global interface reconstruction is used.

Output format changed

Solution quantities of interest

Compile and run the code on INL machine

All code changes are kept under git version control in github: Frontier-µMix

Page 4: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

Wrong phase problem has been fixed

Page 5: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

Previous simulation with small domain in theta

Looking at this interface from the old simulation, we decided toincrease the length of the domain in the theta direction to about 3 times

the gap-length while keeping the axial direction as 2 gap lengths.

Page 6: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

Comparison with different initial velocity field

12.5 ms 11 ms 56.5 ms

laminar flow initial field constant velocity with average of the inner and outer wall speed zero initial velocity

We decided to use the initial velocity in the fluid as zero and reduce the inner cylinder angular speed to 2500 rpm. There will be additional reduction, say, 2000 or 1500 rpm.

Page 7: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

New simulation of 1M case (two phases)

Page 8: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

Results and observations

Page 9: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

(Results and observations cont.)

Initially good results but later times, when mixing is increased, present challenges...

Page 10: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

(Results and observations cont.)

Page 11: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

(Results and observations cont.)

Page 12: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

Movies of interface evolution

Inside view Outside view

Page 13: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

Current status

We are trying to take the system to a fully developed mixing regime. This regime will be achieved when the interfacial area reaches an statistical average. We are running two simulations for 8M (1024 processors) and 16M (2048 processors) cells on INL machines.

8M case : the length of the domain in the theta direction is about 3 times the gap length

16M case : the length of the domain in the theta direction is about 6 times the gap length

Page 14: Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &

Work Plan

1) Work toward reaching fully developed mixing regime Prioritize what is most valuable to reach the goal

Consider initial and boundary conditions (lower rotating speed) Consider domain size (longer axial direction and angular direction) Mesh refinement to avoid catastrophic loss of convergence Revisit global reconstruction to conserve mass Revisit local reconstruction to conserve mass

1) Work to compute solution derived quantities to help guide work in 1) Prioritize what is most valuable to reach the goal