Seung-Jin Lee Dept. of Mechanical Engineering Brendan O’Donnell Dept. of Civil and Environmental Engineering An Energy- Efficient Data Center for the New BIOBuilding
12

Seung-Jin Lee Dept. of Mechanical Engineering ...

Jan 28, 2018

Download

Technology

datacenters
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Seung-Jin Lee Dept. of Mechanical Engineering ...

Seung-Jin Lee Dept. of Mechanical Engineering

Brendan O’DonnellDept. of Civil and Environmental Engineering

An Energy-Efficient Data Center for the New BIOBuilding

Page 2: Seung-Jin Lee Dept. of Mechanical Engineering ...

2An

Ene

rgy-

Eff

icie

nt D

ata

Cen

ter

for

the

New

BIO

Bui

ldin

g

Motivation

“The dramatic increase in campus-wide data server demand in recent years has

outstripped the University’s capacity to meet its instructional, research and administrative

computing requirements. This growth, combined with sharply escalating security

requirements, is expected to continue into the foreseeable future.”

- UW Data Center Task Force

Page 3: Seung-Jin Lee Dept. of Mechanical Engineering ...

3An

Ene

rgy-

Eff

icie

nt D

ata

Cen

ter

for

the

New

BIO

Bui

ldin

g

Agenda

• Power consumption• Current status at UW• Cost savings estimate

• Must account for non-uniform cooling demand

Page 4: Seung-Jin Lee Dept. of Mechanical Engineering ...

4An

Ene

rgy-

Eff

icie

nt D

ata

Cen

ter

for

the

New

BIO

Bui

ldin

g

Impact of Data Centers

PROBLEM: ELECTRICITY

• Increasing data needs (think Google)• 45 billion kWh (~$2.7 billion)• Less than 50% consumed by servers’ CPUs• Rest is for cooling and auxiliary equipment• Server power demand increases

Page 5: Seung-Jin Lee Dept. of Mechanical Engineering ...

5An

Ene

rgy-

Eff

icie

nt D

ata

Cen

ter

for

the

New

BIO

Bui

ldin

g

Data Center Power Drain

Source: Wall Street Journal (12/21/06)

Page 6: Seung-Jin Lee Dept. of Mechanical Engineering ...

6An

Ene

rgy-

Eff

icie

nt D

ata

Cen

ter

for

the

New

BIO

Bui

ldin

g

Current Status – UW Tower

• UW needs 2.5 to 3.0 MW of computing power in coming decade => at least $15 million

• Energy-efficient designs• Limits and constraints

• Floor to ceiling heights• Raised floor height (18”)• Floor loading (75 lb/sf)• Computing density (100 w/sf)• Cooling availability

ROOM FOR IMPROVEMENT

Page 7: Seung-Jin Lee Dept. of Mechanical Engineering ...

7An

Ene

rgy-

Eff

icie

nt D

ata

Cen

ter

for

the

New

BIO

Bui

ldin

g

BIOBuilding Charrette

• Design charrette by professors & graduate students• Prof. Ed Lazowska -- CSE• Large greenhouses, sensors, advanced automation• Next generation of “Living Laboratory”• Server room evaluation

• Why do we need a data center?• Weighted Decision Matrix [UW Capital Planning] • Primary goal of efficiency

Page 8: Seung-Jin Lee Dept. of Mechanical Engineering ...

8An

Ene

rgy-

Eff

icie

nt D

ata

Cen

ter

for

the

New

BIO

Bui

ldin

g

Indicators

• Power consumption (MWh/year)• Average kW/rack• Cooling efficiency• Percentage of electricity for servers’ CPUs

• $’s saved• Life cycle cost savings

• Floor space (ft2) – Density• Average W/ft2

Page 9: Seung-Jin Lee Dept. of Mechanical Engineering ...

9An

Ene

rgy-

Eff

icie

nt D

ata

Cen

ter

for

the

New

BIO

Bui

ldin

g

Design options

• Understand nonuniformity in cooling and power

• Adaptive CRAC chillers• The data center is the

computer• Vary process control

• Direct Current (DC) power• No step down of AC power• Easier with new construction

Source: HP (2005)

Page 10: Seung-Jin Lee Dept. of Mechanical Engineering ...

10An

Ene

rgy-

Eff

icie

nt D

ata

Cen

ter

for

the

New

BIO

Bui

ldin

g

Recommendations

• No one size fits all approach • Size of data center is uncertain for both

• Physical space

• Performance • Must allow for non-uniform cooling

• Next generation technology goal

• Still make estimates of savings with help of thought leaders• Bill Weihl -- Google• Feng Zhao -- Microsoft• Marc Monroe -- Sun Microsystems

• Roughly 350MWh or $24,000 per year savings• Conservative 10% savings

Page 11: Seung-Jin Lee Dept. of Mechanical Engineering ...

11An

Ene

rgy-

Eff

icie

nt D

ata

Cen

ter

for

the

New

BIO

Bui

ldin

g

Acknowledgments

• Ed Lazowska – Chair, Dept. of Computer Science & Eng.• Scott Mah – Assistant VP C&C Service Delivery & Support• Marilyn Cox – Assistant Vice Provost for Cap. Planning• Brad Spencer – Group Manager, Capital Projects Office• Bill Weihl – Google• Feng Zhao – Microsoft Research• Marc Monroe – Sun Microsystems• Bill Courtright – Carnegie Mellon University• Casa Biota Design Team

• Todd Beyreuther• David Haak• Walker Robb

Page 12: Seung-Jin Lee Dept. of Mechanical Engineering ...

12An

Ene

rgy-

Eff

icie

nt D

ata

Cen

ter

for

the

New

BIO

Bui

ldin

g

Typical schematic

Source: Sharma, Bash, Patel, Friedrich, Chase (HP, Duke) (2005)