Top Banner
New Plastic Fenders System : Philosophy / Design Approach Topic Description New standard sheets for fender systems are introduced. The design philosophy, based on energy concepts, is discussed. Use of the standards and limitations are described. Speaker Biography Henry Bollmann is a Senior Structures Design Engineer working in the FDOT Central Office, Tallahasse Fl. Henry received his MSCE degree from the University of Florida in 1974 and has spent his entire professional career working in many facets of bridge engineering while focusing on design. Henry Bollmann Session 62 FL. Dept. of Transportation CO
31

Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

Feb 06, 2018

Download

Documents

dodieu
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

New Plastic Fenders System : Philosophy / Design Approach

Topic Description

New standard sheets for fender systems are introduced. The design philosophy, based on energy concepts, is discussed. Use of the standards and limitations are described.

Speaker Biography

Henry Bollmann is a Senior Structures Design Engineer working in the FDOT Central Office, Tallahasse Fl. Henry received his MSCE degree from the University of Florida in 1974 and has spent his entire professional career working in many facets of bridge engineering while focusing on design.

Henry Bollmann

Session 62

FL. Dept. of Transportation CO

Page 2: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

1

Structures Design Office FDOT Design Conference 2006 Structures Design Office

Fender SystemsFender Systems

Henry Henry BollmannBollmann & Jerry Hocking & Jerry Hocking -- Structures Design OfficeStructures Design Office

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Barge ImpactBarge Impact

Page 3: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

2

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

TopicsTopics

Fender PurposeFender PurposeDesign Guidance & SpecificationsDesign Guidance & SpecificationsStandard Index DrawingsStandard Index Drawings

Heavy Duty Fender SystemHeavy Duty Fender SystemMedium Duty Fender SystemMedium Duty Fender SystemLight Duty Fender SystemLight Duty Fender System

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

TopicsTopics

Guidance for Selection of FenderGuidance for Selection of FenderDesignDesign Method and ExampleMethod and ExampleCost ConsiderationsCost ConsiderationsPlastic Pile Bending TestPlastic Pile Bending TestPile and Wale Capacity ComparisonPile and Wale Capacity Comparison

Page 4: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

3

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

SeabreezeSeabreeze

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

SeabreezeSeabreeze

Page 5: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

4

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Concrete and TimberConcrete and Timber

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Clearwater InletClearwater Inlet

Page 6: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

5

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Boynton BeachBoynton Beach

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

St. George IslandSt. George Island

Page 7: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

6

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Evans CraryEvans Crary

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

SR 312SR 312

Page 8: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

7

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Purpose of Fender SystemPurpose of Fender System

In general, a bridge over a navigable waterway that is under the jurisdiction of the U.S. Coast Guard will have a bridge fender system.Primary function is to delineate channels and redirect aberrant vessels.

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Purpose of Fender SystemPurpose of Fender System

It is considered as a sacrificial structure.The channel pier is designed for full ship impact. i.e. Neglecting effect of fender system.

Page 9: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

8

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Design Guidance and SpecificationsDesign Guidance and Specifications

FDOT Standard SpecificationsFDOT Standard SpecificationsNew Section 973 New Section 973 –– Material Material Requirements of Plastic Piles and Requirements of Plastic Piles and WalesWalesNew Section 471 New Section 471 –– Construction & Construction & Installation of Fender SystemInstallation of Fender SystemModify Section 455Modify Section 455--44 44 –– Installation Installation Requirements of Plastic PilesRequirements of Plastic Piles

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Design Guidance and SpecificationsDesign Guidance and Specifications

SDG Section 3.14 SDG Section 3.14 –– Fender SystemsFender SystemsSDM Chapter 12 SDM Chapter 12 –– Fender SystemsFender SystemsAASHTO AASHTO –– Guide Specification and Guide Specification and Commentary For Vessel Collision Commentary For Vessel Collision Design of Highway BridgesDesign of Highway Bridges

C3.8 Vessel Collision EnergyC3.8 Vessel Collision EnergyC7.3.1 Fender SystemsC7.3.1 Fender Systems

Page 10: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

9

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

New Standard Index DrawingsNew Standard Index Drawings

Index 21900 Index 21900 –– General Notes & LayoutGeneral Notes & LayoutIndex 21910 Index 21910 –– Heavy Duty Fender SystemHeavy Duty Fender SystemIndex 21920 Index 21920 –– Medium Duty Fender Medium Duty Fender SystemSystemIndex 21930 Index 21930 –– Light Duty Fender SystemLight Duty Fender SystemCADD Cells for Quantities and List of CADD Cells for Quantities and List of VariablesVariables

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Plan and ElevationPlan and Elevation

Page 11: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

10

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

SS Bolts

Spacer Blocks

16” dia. Piles

Page 12: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

11

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

SS Splice Plate

SS Bolts

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

PilesPiles

Pile SpacingPile SpacingHeavy Duty Fender Heavy Duty Fender –– Spacing = 5Spacing = 5’’-- 44””Medium Duty Fender Medium Duty Fender –– Spacing = 8Spacing = 8’’-- 00””Light Duty Fender Light Duty Fender –– Spacing = 5Spacing = 5’’-- 44””

Page 13: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

12

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

PilesPiles

Pile LengthPile Length8 feet above MHW8 feet above MHWMHW MHW -- MLW (approx. 4 feet )MLW (approx. 4 feet )Channel depth 12 feet Channel depth 12 feet Approximate soil embedment 24 feet Approximate soil embedment 24 feet 48 feet total48 feet total

All Piles Driven Plumb All Piles Driven Plumb

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

WalesWales

Wale lengths and sizeWale lengths and size16 & 32 feet in length16 & 32 feet in length

Over lapping joints at splice locations Over lapping joints at splice locations for greater continuity strength at pile for greater continuity strength at pile locations.locations.

1010”” x 10x 10”” squaresquareStainless steel connection bolts and Stainless steel connection bolts and splice plates.splice plates.

Page 14: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

13

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

CatwalkCatwalk

Two deck options availableTwo deck options availablePlastic marine lumber (nonPlastic marine lumber (non--reinforced)reinforced)Fiberglass open gratingFiberglass open grating

Width 2Width 2’’--66””

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

General Layout Sheet and General Layout Sheet and Table of VariablesTable of Variables

Page 15: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

14

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Table of VariablesTable of Variables

Control Point “C”

Station

Offset

Dimension “L”

Cle

ar

Cha

nnel

Skew Angle

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Page 16: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

15

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Guidance For Selection of Guidance For Selection of Fender SystemFender System

From SDG 3.14.3B and 3.14.4CFrom SDG 3.14.3B and 3.14.4CHeavy Duty Fender SystemHeavy Duty Fender System

Channel pier strength requirement Channel pier strength requirement from risk analysis exceeds 2500 kipsfrom risk analysis exceeds 2500 kipsi.e. Two loaded jumbo hopper barges i.e. Two loaded jumbo hopper barges + push boat at 4.0 knots+ push boat at 4.0 knots

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Guidance For Selection of Guidance For Selection of Fender SystemFender System

Medium Duty Fender SystemMedium Duty Fender SystemChannel pier strength requirement Channel pier strength requirement from risk analysis 1000 to 2500 kipsfrom risk analysis 1000 to 2500 kipsi.e. One loaded jumbo hopper barge + i.e. One loaded jumbo hopper barge + push boat at 3.6 knotspush boat at 3.6 knots

Page 17: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

16

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Guidance For Selection of Guidance For Selection of Fender SystemFender System

Light Duty Fender SystemLight Duty Fender SystemMinor commercial traffic, pier strength Minor commercial traffic, pier strength requirement less than 1000 kipsrequirement less than 1000 kipsi.e. One unloaded jumbo hopper i.e. One unloaded jumbo hopper barge + push boat at 4.2 knotsbarge + push boat at 4.2 knots

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Design MethodologyDesign Methodology

The loss of kinetic energy of the vessel is transformed into an equal amount of energy absorbed by the protective structure. The kinetic impact energy is dissipated by the work done by the displacement of the protective system.

Page 18: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

17

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Design MethodologyDesign Methodology

Develop a force versus deflection diagram via analysis or physical testing. The area under the diagram is the energy capacity of the protective system. The forces and energy capacity of the protective system is then compared with the design vessel impact force and energy to determine if the vessel loads have been safely resisted.

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Design AssumptionsDesign Assumptions

Channel Depth at MHW 12 ft.Channel Depth at MHW 12 ft.8 ft. from MHW to top of pile8 ft. from MHW to top of pileWeak cohesionless soilWeak cohesionless soil

Phi = 30 deg.Phi = 30 deg.Subgrade modulus = 20 pciSubgrade modulus = 20 pci

Page 19: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

18

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Design AssumptionsDesign Assumptions

Coefficient of friction (mu) between Coefficient of friction (mu) between barge and plastic wale = 0.15barge and plastic wale = 0.15Impact angle = 15 deg.Impact angle = 15 deg.

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Design MethodologyDesign Methodology

η KEbarge⋅ Workfender≤

Governing EquationGoverning Equation

Page 20: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

19

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Design MethodologyDesign Methodology

Work done by Fender System Work done by Fender System (Absorbed Energy)(Absorbed Energy)

Increment load until Pile Nominal Increment load until Pile Nominal Moment Capacity is reachedMoment Capacity is reachedFind DeflectionFind Deflection

∑Work fender

12

P i∑⋅ Δ i⋅

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

FBFB--Pier Model Pier Model Medium Duty FenderMedium Duty Fender

Page 21: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

20

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Fender EnergyFender Energy

Area = 132 k-f

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

KE12

M⋅ V2⋅

2 g⋅tonne

kip

29.18ft

sec2=KE

12

CH⋅Wg

⋅ V2⋅

KECH W⋅ V2

29.2

Barge EnergyBarge Energy

Kinetic Energy of Barge (Vessel Energy)Kinetic Energy of Barge (Vessel Energy)

Page 22: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

21

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Design Example Design Example Medium Duty FenderMedium Duty Fender

1 loaded jumbo hopper barge => 1900 tons1 loaded jumbo hopper barge => 1900 tons

Push boat => 260 tonsPush boat => 260 tons

Total Weight W = 1900 + 260 = 2160 tons, 1956 tonnesTotal Weight W = 1900 + 260 = 2160 tons, 1956 tonnes

nn*KE*KEbargebarge = = nn*Ch*W*V*Ch*W*V22 /29.2= Energy/29.2= Energyfenderfender

nn = 0.05 (for= 0.05 (for mu = 0.15 & angle of impact = 15 deg.)mu = 0.15 & angle of impact = 15 deg.)fig. C3.8fig. C3.8--1 1 AASHTO AASHTO –– Guide Specification andGuide Specification andCommentary For Vessel Collision Design of Highway Commentary For Vessel Collision Design of Highway BridgesBridges

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Determination of EtaDetermination of Eta

0.05

For:

Mu = 0.15

Alpha = 15 deg.

Graph shows:

Eta = 0.05

15 deg.

Page 23: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

22

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Design Example Design Example Medium Duty FenderMedium Duty Fender

1 loaded jumbo hopper barge => 1900 tons1 loaded jumbo hopper barge => 1900 tons

Push boat => 260 tonsPush boat => 260 tons

Total Weight W = 1900 + 260 = 2160 tons, 1956 tonnesTotal Weight W = 1900 + 260 = 2160 tons, 1956 tonnes

nn*KE*KEbargebarge = = nn*Ch*W*V*Ch*W*V22 / 29.2 = Energy/ 29.2 = Energyfenderfender

nn = 0.05 (for= 0.05 (for mu = 0.15 & angle of impact = 15 deg.)mu = 0.15 & angle of impact = 15 deg.)fig. C3.8fig. C3.8--1 1 AASHTO AASHTO –– Guide Specification andGuide Specification andCommentary For Vessel Collision Design of Highway Commentary For Vessel Collision Design of Highway BridgesBridges

Ch = 1.05 for under keel clearanceCh = 1.05 for under keel clearance

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Design Example Design Example Medium Duty FenderMedium Duty Fender

nn*KE*KEbargebarge = = nn*Ch*W*V*Ch*W*V22 /29.2/29.2 = Energy= Energyfenderfender

nn*KE*KEbargebarge = 0.05*1.05*1956*V= 0.05*1.05*1956*V22 /29.2= 132k/29.2= 132k--ff

Solving for velocity: V= 6.12 f/s = 3.62 knotsSolving for velocity: V= 6.12 f/s = 3.62 knots

Page 24: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

23

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Initial Cost ConsiderationsInitial Cost Considerations

There are multiple sources of supply of the There are multiple sources of supply of the Structural Plastic piles and timbers. Structural Plastic piles and timbers. Therefore, there will be competitive bids.Therefore, there will be competitive bids.In terms of cost per lineal foot, Structural In terms of cost per lineal foot, Structural Plastic piles are twice the cost of 14Plastic piles are twice the cost of 14””square prestressed concrete piles. square prestressed concrete piles. Total cost of Plastic Fender System is Total cost of Plastic Fender System is approximately twice that of the 14approximately twice that of the 14”” square square concrete pile system.concrete pile system.

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Initial Cost ConsiderationsInitial Cost Considerations

However, when comparing cost you must However, when comparing cost you must consider the entire system. For example, consider the entire system. For example, the typical mediumthe typical medium--duty structural plastic duty structural plastic system uses approximately 100 system uses approximately 100 -- 1616”” OD OD structural plastic piles versus the structural plastic piles versus the traditional prestressed concrete pile traditional prestressed concrete pile system that uses over 200.system that uses over 200.

Page 25: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

24

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Initial Cost ConsiderationsInitial Cost Considerations

The higher, per lineal foot cost of the The higher, per lineal foot cost of the structural plastic piles is offset by 2 structural plastic piles is offset by 2 factors:factors:

Fewer piles means the material cost is Fewer piles means the material cost is reducedreducedFewer piles reduces labor cost (less pile Fewer piles reduces labor cost (less pile driving)driving)

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

LifeLife--Cycle Cost ConsiderationsCycle Cost Considerations

Expect structural plastic members to last Expect structural plastic members to last the life of the bridge (75+ years). the life of the bridge (75+ years). Stainless hardware will fail before the Stainless hardware will fail before the structural plastic piles & timbers.structural plastic piles & timbers.

Page 26: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

25

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

LifeLife--Cycle Cost Considerations Cycle Cost Considerations

In contrast, timber and concrete have a far In contrast, timber and concrete have a far shorter service life:shorter service life:

Timber Timber waleswales offer a maximum service life of offer a maximum service life of 1010--15 years15 yearsPrestressed concrete piles begin failing at the Prestressed concrete piles begin failing at the time of the first significant impact to the fender time of the first significant impact to the fender system. The prestressed pile cracks on system. The prestressed pile cracks on impact, seawater corrodes steel reinforcing impact, seawater corrodes steel reinforcing strands & the concrete begins to spall.strands & the concrete begins to spall.

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

LifeLife--Cycle Cost ConsiderationsCycle Cost Considerations

In contrast, structural plastic fender In contrast, structural plastic fender systems absorb the energy of these systems absorb the energy of these impacts without requiring any impacts without requiring any maintenance. As a result, the structural maintenance. As a result, the structural plastic fender systems offer a substantially plastic fender systems offer a substantially lower life cycle cost for the State of lower life cycle cost for the State of Florida. Florida.

Page 27: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

26

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Wale Bending TestWale Bending Test

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Page 28: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

27

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

1010”” sq. Plastic Wale sq. Plastic Wale LoadLoad--Displacement CurveDisplacement Curve

1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 162

0

2

4

6

8

10

12

14

16

18

20

22

24

new waleold wale 2old wale 1 initial testold wale 1 final test

displacement (inches)

load

(kip

s)

P = 22.4 k Mn = 78.4 k-f

Load

(k)

Displacement (in)

P = 18.5 k My = 58 k-f

My = S*Fy (Fy = 4.5 ksi)

35 %

4 – 1.25”dia. bars

4 – 1” dia. bars

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

FullFull--Scale TestingScale Testing

Page 29: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

28

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

EnergyEnergy--Absorption ComparisonAbsorption Comparison

190 kN

42.7 k

267

mm

10.5

in

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Plastic Pile DesignPlastic Pile Design

Page 30: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

29

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Fender Pile CapacitiesFender Pile Capacities

19216516” dia. FRPw/16 - 1” dia. bars

12811014” sq. PS Concrete Pilew/8 - ½” dia. strand

1008612” dia. Timber Pile

35330416” dia. FRPw/16 – 1 1/2” dia. bars

% of Timber

Pile

Mn (k-f)Element

Moment Capacities

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

1074510” sq. Plastic Walew/4 - 1” dia. bars

1004210” sq. Timber Wale

1817610” sq. Plastic Walew/4 - 1 1/2” dia. bars

% of Timber Wale

Mn (k-f)Element

Moment Capacities

Fender Wale CapacitiesFender Wale Capacities

Page 31: Session 62 Henry Bollmann - Florida Department of ... · PDF fileSession 62 FL. Dept. of ... Over lapping joints at splice locations ... impact, seawater corrodes steel reinforcing

30

FDOT Design Conference 2006 Structures Design Office FDOT Design Conference 2006 Structures Design Office

Questions / CommentsQuestions / Comments

Henry Bollmann, P.E. Henry Bollmann, P.E. Structures Design OfficeStructures Design Office

Florida Department of TransportationFlorida Department of Transportation605 Suwannee St., MS 33605 Suwannee St., MS 33

Tallahassee, Fl. 32399Tallahassee, Fl. [email protected]@dot.state.fl.us