1289697-2A-A 1 BEFORE YOU BEGIN All information is based on the latest product information available at the time of publication. Kohler Co. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. Please leave these instructions for the consumer. They contain important information. NOTES: 1. Shut off the main water supply. 2. Carefully read entire instructions before beginning installation. 3. Observe local plumbing codes. 4. The highest working pressure for handshower & showerhead is 0.5MPa(5bar). If it exceeds 0.5MPa(5bar), a pressure reducer is needed. The highest water and environment temperature is 60ºC. Please keep handshower, showerhead and shower arm away from heater, or it may become damaged and cause injury to the user. 1289697-2A-A 4 INSTALLATION INSTRUCTIONS 77989T-8A Handshower With Control COMPONENTS 77989T-8A Handshower With Control COMPONENTS SERVICE PARTS ROUGH-IN DIMENSIONS HANDLE OPERATION Lift the handle gently. Turn clockwise for hot water, turn counter-clockwise for cold water. **Color code must be specified when ordering. 1240266 1297467** 1249005 3027088** 1024326 834792 1227446 1289688** 1070967 1070967 1289693 1289694 1024405 831587 1045198 831752 831289 1302055 1289691** 898324** 3026818** 3016159 75100** 22352 1110332 3029882 831587 834428 1030624 77420 1258113 Ø60 Ø28 Ø33~Ø40 240 132 600 Ø60 Ø43~Ø50 30.5 40 Max. 285
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1289697-2A-A 1
BEFORE YOU BEGIN
All information is based on the latest product information available at the time of publication. Kohler Co. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice.
Please leave these instructions for the consumer. They contain important information.
NOTES:1. Shut off the main water supply.2. Carefully read entire instructions before beginning installation.3. Observe local plumbing codes.4. The highest working pressure for handshower & showerhead is 0.5MPa(5bar). If it exceeds 0.5MPa(5bar), a pressure reducer is needed. The highest water and environment temperature is 60ºC. Please keep handshower, showerhead and shower arm away from heater, or it may become damaged and cause injury to the user.
1289697-2A-A 4
INSTALLATION INSTRUCTIONS
77989T-8A Handshower With Control
COMPONENTS77989T-8A Handshower With Control
COMPONENTSSERVICE PARTS
ROUGH-IN DIMENSIONS
HANDLE OPERATION
Lift the handle gently. Turn clockwise for hot water, turn counter-clockwise for cold water.
**Color code must be specified when ordering.
1240266
1297467**
1249005
3027088**
1024326
834792
1227446
1289688**
1070967
1070967
1289693
1289694
1024405
831587
1045198
831752
831289
1302055
1289691**
898324**
3026818**
3016159
75100**
22352
1110332
3029882
831587
834428
103062477420
1258113
Ø60
Ø28
Ø33~Ø40
240
132
600
Ø60
Ø43~Ø50
30.5
40 M
ax.
285
1289697-2A-A 2
1289697-2A-A 3
CLEANING INSTRUCTIONS
All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc, which could adversely affect the finish and are not recommended for cleaning.
Do not use abrasive cleaners or solvents on Kohler faucets and fittings.
INSTALLATION
INSTALLATION CHECKOUT
10
8
4
3
12
5
6
7
9
How to Install the Handle Kit
Install the washer(2) into the groove of the handle kit(1). Insert the handle kit with washer to the mounting hole. Adjust the handle. Make sure the handle with red dot is on the left side and blue dot on the right side.
Install the screws(7) into the threaded ring(6).From underside, slide the washer(4) and washer(5) to the body(3). Screw the threaded ring. Tighten the screws to secure the handle kit.
Attach the two hoses(8) to water supplies. When facing front of the faucet, the left hose connects to hot water, the right hose with “COLD” label should be connected to cold water. Connect the rear hose(9) and the hose assembly(10).
How to Operate the Handshower
Press the buttons of the handshower to change the water flow.
Ensure all coupling nuts are tight. Turn on main water supply and check for leaks. Repair as required.
10
11
15
16
12
14
17
181920
13
How to Install the Handshower
Adhere the washer(15) to the bottom of the escutcheon(14). Screw the escutcheon to the shank(16). Place the shank into the mounting hole until the escutcheon against the deck.
Install the screws(20) into the fixing ring(19).From underside, slide the washer(17, 18) to the shank. Screw the fixing ring. Tighten the screws to secure the shank.
Slide the hose(13) through the escutcheon, and attach to the other end of the hose assembly(10).
Install the restrictor(12) into the inlet of the handshower(11) if needed. Connect the hose(13) and handshower.
How to Maintain the Handshower
Any debris or mineral build-up may cause the flow stream to become distorted or reduce the flow rate. To remove the debris or mineral build-up, run water through the handshower, firmly press or rub your finger back and forth across the rubber nozzles.