RS6200006r32 December 2011 This manual is to be used by qualified, professionally trained HVAC techni- cians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. Copyright © 2006 - 2011 Goodman Manufacturing Company, L.P. SSX, ASX, GSX, DSX, ASXC, DSXC Condensing Units, SSZ, ASZ, GSZ, DSZ, ASZC, DSZC, VSX, VSZ Split System Heat Pumps with R-410A Refrigerant Blowers, Coils, & Accessories Service Instructions
131
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Service Manual - R410a - RS6200006R32[1]

RS6200006r32December 2011

This manual is to be used by qualified, professionally trained HVAC techni-cians only. Goodman does not assume any responsibility for propertydamage or personal injury due to improper service procedures or servicesperformed by an unqualified person.

Copyright © 2006 - 2011 Goodman Manufacturing Company, L.P.

SSX, ASX, GSX, DSX, ASXC, DSXC Condensing Units,SSZ, ASZ, GSZ, DSZ, ASZC, DSZC, VSX, VSZ Split System

Heat Pumpswith R-410A Refrigerant

Blowers, Coils, & Accessories

Service Instructions

Page 2: Service Manual - R410a - RS6200006R32[1]

Pride and workmanship go into every product to provide our customers with quality products. It is possible, however, thatduring its lifetime a product may require service. Products should be serviced only by a qualified service technician who isfamiliar with the safety procedures required in the repair and who is equipped with the proper tools, parts, testing instrumentsand the appropriate service manual. REVIEW ALL SERVICE INFORMATION IN THE APPROPRIATE SERVICE MANUAL BEFOREBEGINNING REPAIRS.

IMPORTANT NOTICES FOR CONSUMERS AND SERVICERSRECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS

WARNING

THIS UNIT SHOULD NOT BE CONNECTED TO. OR USED IN CONJUNCTION WITH, ANY DEVICES THAT ARE NOT DESIGN CERTIFIED FOR USE WITH THIS UNIT OR HAVE NOT BEENTESTED AND APPROVED BY GOODMAN. SERIOUS PROPERTY DAMAGE OR PERSONAL INJURY, REDUCED UNIT PERFORMANCE AND/OR HAZARDOUS CONDITIONS MAY RESULTFROM THE USE OF DEVICES THAT HAVE NOT BEEN APPROVED OR CERTIFED BY GOODMAN.

WARNING

TO PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH,DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHERFLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS APPLIANCE.

WARNING

GOODMAN WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCEDURES.IF YOU INSTALL OR PERFORM SERVICE ON THIS UNIT, YOU ASSUME RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY DAMAGE WHICHMAY RESULT. MANY JURISDICTIONS REQUIRE A LICENSE TO INSTALL OR SERVICE HEATING AND AIR CONDITIONING EQUIPMENT.

To locate an authorized servicer, please consult your telephone book or the dealer from whom you purchased this product.For further assistance, please contact:

CONSUMER INFORMATION LINE

IMPORTANT INFORMATION

GOODMAN® BRAND PRODUCTSTOLL FREE

1-877-254-4729 (U.S. only)email us at: [email protected]

fax us at: (713) 856-1821(Not a technical assistance line for dealers.)

AMANA® BRAND PRODUCTSTOLL FREE

1-877-254-4729 (U.S. only)email us at: [email protected]

fax us at: (713) 856-1821(Not a technical assistance line for dealers.)

IMPORTANT INFORMATION ............................................... 2 - 3

PRODUCT IDENTIFICATION ............................................. 4 -25

PRODUCT IDENTIFICATION (LIGHT COMMERCIAL) ... 26 - 27

ACCESSORIES (LIGHT COMMERCIAL) ............................... 28

ACCESSORIES ............................................................... 29 - 44

PRODUCT DESIGN ........................................................45 - 47

SYSTEM OPERATION .....................................................48 - 52

TROUBLESHOOTING CHART .............................................. 53

SERVICE TABLE OF CONTENTS ......................................... 54

SERVICING .................................................................. 55 - 123

ACCESSORIES WIRING DIAGRAMS ........................ 124 - 131

Outside the U.S., call 1-713-861-2500.(Not a technical assistance line for dealers.) Your telephone company will bill you for the call.

Page 3: Service Manual - R410a - RS6200006R32[1]

SAFE REFRIGERANT HANDLINGWhile these items will not cover every conceivable situation, they should serve as a useful guide.

IMPORTANT INFORMATION

The successful development of hermetically sealed refrigera-tion compressors has completely sealed the compressor'smoving parts and electric motor inside a common housing,minimizing refrigerant leaks and the hazards sometimesassociated with moving belts, pulleys or couplings.Fundamental to the design of hermetic compressors is amethod whereby electrical current is transmitted to thecompressor motor through terminal conductors which passthrough the compressor housing wall. These terminals aresealed in a dielectric material which insulates them from thehousing and maintains the pressure tight integrity of thehermetic compressor. The terminals and their dielectricembedment are strongly constructed, but are vulnerable tocareless compressor installation or maintenance proce-dures and equally vulnerable to internal electrical shortcircuits caused by excessive system contaminants.

In either of these instances, an electrical short between theterminal and the compressor housing may result in the lossof integrity between the terminal and its dielectric embed-ment. This loss may cause the terminals to be expelled,thereby venting the vaporous and liquid contents of thecompressor housing and system.A venting compressor terminal normally presents no dangerto anyone, providing the terminal protective cover is properlyin place.If, however, the terminal protective cover is not properly inplace, a venting terminal may discharge a combination of

(a) hot lubricating oil and refrigerant(b) flammable mixture (if system is contaminated

with air)in a stream of spray which may be dangerous to anyone in thevicinity. Death or serious bodily injury could occur.Under no circumstances is a hermetic compressor to beelectrically energized and/or operated without having theterminal protective cover properly in place.See Service Section S-17 for proper servicing.

WARNING

REFRIGERANTS ARE HEAVIER THAN AIR. THEY CAN "PUSH OUT" THEOXYGEN IN YOUR LUNGS OR IN ANY ENCLOSED SPACE. TO AVOIDPOSSIBLE DIFFICULTY IN BREATHING OR DEATH:•NEVER PURGE REFRIGERANT INTO AN ENCLOSED ROOM OR SPACE. BY LAW, ALL REFRIGERANTS MUST BE RECLAIMED.•IF AN INDOOR LEAK IS SUSPECTED, THOROUGHLY VENTILATE THE AREA BEFORE BEGINNING WORK.•LIQUID REFRIGERANT CAN BE VERY COLD. TO AVOID POSSIBLE FROST- BITE OR BLINDNESS, AVOID CONTACT WITH REFRIGERANT AND WEAR GLOVES AND GOGGLES. IF LIQUID REFRIGERANT DOES CONTACT YOUR SKIN OR EYES, SEEK MEDICAL HELP IMMEDIATELY.•ALWAYS FOLLOW EPA REGULATIONS. NEVER BURN REFRIGERANT, AS POISONOUS GAS WILL BE PRODUCED.

WARNING

SYSTEM CONTAMINANTS, IMPROPER SERVICE PROCEDURE AND/OR PHYSICALABUSE AFFECTING HERMETIC COMPRESSOR ELECTRICAL TERMINALS MAYCAUSE DANGEROUS SYSTEM VENTING.

WARNING

TO AVOID POSSIBLE INJURY, EXPLOSION OR DEATH, PRACTICE SAFEHANDLING OF REFRIGERANTS.

WARNING

TO AVOID POSSIBLE EXPLOSION, USE ONLY RETURNABLE (NOT DISPOSABLE)SERVICE CYLINDERS WHEN REMOVING REFRIGERANT FROM A SYSTEM.• ENSURE THE CYLINDER IS FREE OF DAMAGE WHICH COULD LEAD TO A LEAK OR EXPLOSION.• ENSURE THE HYDROSTATIC TEST DATE DOES NOT EXCEED 5 YEARS.• ENSURE THE PRESSURE RATING MEETS OR EXCEEDS 400 LBS.

WHEN IN DOUBT, DO NOT USE CYLINDER.

WARNING

TO AVOID POSSIBLE EXPLOSION:• NEVER APPLY FLAME OR STEAM TO A REFRIGERANT CYLINDER. IF YOU MUST HEAT A CYLINDER FOR FASTER CHARGING, PARTIALLY IMMERSE IT IN WARM WATER.• NEVER FILL A CYLINDER MORE THAN 80% FULL OF LIQUID REFRIGERANT.• NEVER ADD ANYTHING OTHER THAN R-22 TO AN R-22 CYLINDER OR R-410A TO AN R-410A CYLINDER. THE SERVICE EQUIPMENT USED MUST BE LISTED OR CERTIFIED FOR THE TYPE OF REFRIGERANT USED.• STORE CYLINDERS IN A COOL, DRY PLACE. NEVER USE A CYLINDER AS A PLATFORM OR A ROLLER.

WARNING

THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY ("EPA")HAS ISSUED VARIOUS REGULATIONS REGARDING THE INTRODUCTION ANDDISPOSAL OF REFRIGERANTS INTRODUCED INTO THIS UNIT. FAILURE TOFOLLOW THESE REGULATIONS MAY HARM THE ENVIRONMENT AND CANLEAD TO THEH IMPOSITION OF SUBSTANTIAL FINES. THESE REGULATIONSMAY VARY BY JURISDICTION. SHOULD QUESTIONS ARISE, CONTACT YOURLOCAL EPA OFFICE.

Page 4: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

4

Model # Description

GSZ13**1AA Goodman Split Z R410A Heat Pump 13 Seer heat pump units. Initial release with Regal Beloit motor.

GSZ13**1ABGSZ13**3AAGSZ13**4AA

Goodman Split Z R410A Heat Pump 13 Seer heat pump units. Initial release with Broad Ocean motor.

GSZ130[24 & 30]1AC Goodman Split Z R410A Heat Pump 13 Seer heat pump units. Introduces new revisions with improved circuiting for effective defrost.

GSZ130[24 & 36]1BA Goodman Split Z R410A Heat Pump 13 Seer heat pump units. Initial release of models with 5mm Smart Coil™.

GSZ130[18, 42-60]1ACGSZ130301ADGSZ130361BB

Goodman Split Z R410A Heat Pump 13 Seer heat pump units. Introduces models containing crankcase heater, CCH switch and upgraded defrost control.

GSZ130[18,42,48,60]1ADGSZ130301AE

GSZ130[36,48,60{3,4]ABGSZ130[48,60{3,4]AB

Goodman Split Z R410A Heat Pump 13 Seer heat pump units. Relocation of low pressure switch from liquid line to suction line as a compressor safeguard to prevent low pressurefrom entering.

GSZ130361BCGSZ130[42 & 48]1AE

Goodman Split Z R410A Heat Pump 13 Seer heat pump units. Release of models with new 6 pole motor/fan combination.

GSZ130[36 & 48]3AC Goodman Split Z R410A Heat Pump 13 Seer heat pump units. Release of 3 phase models with new 6 pole motor.

GSZ14**1AA Goodman Split Z R410A Heat Pump 14 Seer heat pump units. Initial release of 14 SEER models.

SSZ140**1AA Special High Feature Split Z R410A heat pump 14 Seer heat pump units. Initial release of Goodman 14 SEER Heat Pump R410A.

SSZ140**1AB Special High Feature Split Z R410A heat pump 14 Seer heat pump units. Introduces new revisions have screw locations moved in the top panel, base pans, louvers, and control box covers.

SSZ140**1AC Special High Feature Split Z R410A heat pump 14 Seer heat pump units. Models contain Broad Ocean motors.

SSZ140181ACSSZ140241AFSSZ140301AD

Special High Feature Split Z R410A heat pump 14 Seer heat pump units. Introduces new revisions adding mufflers to the discharge line.

SSZ140361AFSSZ140421AD

SSZ140[48-60]1AD

Special High Feature Split Z R410A heat pump 14 Seer heat pump units. New revisions replace TXV & compensator with flowrator & accumulator; adds mufflers on SSZ14036`, 421, 481, 601.

SSZ140[18, 30, 42-60]1AESSZ140241AHSSZ14036]1AG

Special High Feature Split Z R410A heat pump 14 Seer heat pump units. New revisions will have Sanhua (RANCO) reversing valves.

SSZ140[18,30,42-60]1AFSSZ140241AJSSZ160361AH

Special High Feature Split Z R410A heat pump 14 Seer heat pump units. Introduces models containing an accumulator, crankcase heater, and upgraded defrost control.

SSZ140241AG Special High Feature Split Z R410A heat pump 14 Seer heat pump units. AG revision has the smaller B1227315 reversing valve.

SSZ140[18-60]1AD Special High Feature Split Z R410A heat pump 14 Seer heat pump units. Relocation of low pressure switch from liquid line to suction line as a compressor safeguard to prevent low pressure from entering.

SSZ140361AFSSZ140421AD

SSZ140[48-60]1AD

Special High Feature Split Z R410A heat pump 14 Seer heat pump units. Initial release of Goodman 14 SEER Heat Pump R410A, with reduced chassis size from large to medium.

SSZ160**1AA Special High Feature Split Z R410A heat pump 16 Seer heat pump units. Initial release of Goodman 16 SEER Heat Pump R410A.

SSZ160**1AB Special High Feature Split Z R410A heat pump 16 Seer heat pump units. Introduces new revisions have screw locations moved in the top panel, base pans, louvers, and control box covers.

SSZ160[24-48]1ACSSZ160601AD

Special High Feature Split Z R410A heat pump 16 Seer heat pump units. Introduces new revisions adding mufflers to the discharge line.

SSZ160**1ACSpecial High Feature Split Z R410A heat pump 16 Seer heat pump units.Introduces models containing the Broad Ocean motor and added Muffler and standardized TXV, Compensator using the ASZ18 Seer weldment to the SSZ160601AC.

SSZ160241AFSSZ160[36, 48]1AD

SSZ160601AE

Special High Feature Split Z R410A heat pump 16 Seer heat pump units.New revisions will have Sanhua (RANCO) reversing valves.

Split System Heat Pumps R410A

Page 5: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

5

Model # Description

DSZ160**1AA Deluxe Split Z Heat Pump 16 Seer heat pump units. Introduces Goodman 2-stage 16 SEER heat pumps with R-410A.

DSZ160241ACDSZ16036, 48, 60]1AB

Deluxe Split Z Heat Pump 16 Seer heat pump units. Goodman 2-stage 16 SEER heat pumps with R-410A. New revisions will have Sanhua (RANCO) reversing valves.

DSZ180**1AA Deluxe Split Z Heat Pump 18 Seer heat pump units. Introduces Goodman 2-stage 18 SEER heat pumps with R-410A.

DSZ180[36, 48, 60]1AB Deluxe Split Z Heat Pump 18 Seer heat pump units. Goodman 2-stage 18 SEER heat pumps with R-410A. New revisions will have Sanhua (RANCO) reversing valves.

DSZC16**1AA Deluxe Split Z Communicating heat pump, 16 Seer R410A heat pump units. Introduces Goodman 2-stage 16 SEER heat pumps with R-410A, communicating models.

DSZC16[24, 36]1ABDSZC16[48, 60]1AB

Deluxe Split Z Communicating heat pump, 16 Seer R410A heat pump units. Goodman 2-stage 16 SEER heat pumps with R-410A, communicating models. New revisions will have Sanhua (RANCO) reversing valves.

DSZC160[24-48]1ACDSZC160601BA

Deluxe Split Z Communicating heat pump, 16 Seer R410A heat pump units. Introduces Goodman 2-stage 16 SEER heat pumps with accumulators and crankcase heaters.

DSZC18**1AA Deluxe Split Z Communicating heat pump, 18 Seer R410A heat pump units. Introduces Goodman 2-stage 18 SEER heat pumps with R-410A, communicating models.

DSZC180[36, 48, 60]1ABDeluxe Split Z Communicating heat pump, 18 Seer R410A heat pump units. Goodman 2-stage 18 SEER heat pumps with R-410A, communicating models. New revisions will have Sanhua (RANCO) reversing valves.

DSZC180[36-48]1ACDSZC180601BA

Deluxe Split Z Communicating heat pump, 18 Seer R410A heat pump units. Introduces Goodman 2-stage 18 SEER heat pumps with accumulators and crankcase heaters.

VSZ13**1AA Value Split Z heat pump, 13 Seer R410A heat pump units. Introduces Value Line 13 SEER heat pumps with R-410A.

VSZ130[24 & 30]1AB Value Split Z heat pump, 13 Seer R410A heat pump units. Introduces new revisions with improved circuiting for effective defrost.

VSZ130[24 & 36]1BA Value Split Z heat pump, 13 Seer R410A heat pump units. Initial release of models with 5mm Smart Coil™.

VSZ130[18, 42, 48]1ABVSZ130241BBVSZ130301AC

Value Split Z heat pump, 13 Seer R410A heat pump units. Introduces models containing crankcase heater, CCH switch and upgraded defrost control.

VSZ130[24 & 36]1BCVSZ130301AE

VSZ130[18, 42 & 48]1AD

Value Split Z heat pump, 13 Seer R410A heat pump units. Release of single phase models with new 6 pole motor.

VSZ130[18, 42-60]1ACVSZ130301AD

Value Split Z heat pump, 13 Seer R410A heat pump units. Relocation of low pressure switch from liquid line to suction line as a compressor safeguard to prevent low pressure from entering.

Split System Heat Pumps R410A

Page 6: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

6

Model # Description

ASZ130**1AA Amana® Brand Split Z R410A heat pump 13 Seer heat pump units. Initial release of Amana® Brand 13 SEER Heat Pump R410A.

ASZ130**1AB Amana® Brand Split Z R410A heat pump 13 Seer heat pump units. Introduces new revisions with imporved circuiting for effective defrost.

ASZ130[18, 36-60]1ABASZ130[24-30]1AC

Amana® Brand Split Z R410A heat pump 13 Seer heat pump units. Introduces models containing crankcase heater, CCH switch and upgraded defrost control.

ASZ130[18, 36-60]1ACASZ130[24-30]1AD

Amana® Brand Split Z R410A heat pump 13 Seer heat pump units. Relocation of low pressure switch from liquid line to suction line as a compressor safeguard to prevent low pressure from entering.

ASZ130[18, 36-60]1ADASZ130[24-30]1AE

Amana® Brand Split Z R410A heat pump 13 Seer heat pump units. Initial release of models using single speed PSC motors; removal of low ambient temperature switch.

ASZ140**1AA Amana® Brand Split Z R410A heat pump 14 Seer heat pump units. Initial release of Amana® Brand 14 SEER Heat Pump R410A.

ASZ140**1AB Amana® Brand Split Z R410A heat pump 14 Seer heat pump units. Introduces new revisions have screw locations moved in the top panel, base pans, louvers, and control box covers.

ASZ140**1AC Amana® Brand Split Z R410A heat pump 14 Seer heat pump units. New revisions have horizontal style louvers.

ASZ140[18, 42-48]1ADASZ140[24-36, 60]1AE

Amana® Brand Split Z R410A heat pump 14 Seer heat pump units. Adds new steel muffler, and suction tubes w/shock loop.

ASZ140[18, 30,36]1AFASZ140241AG

ASZ14[42, 48, 60]1AE

Amana® Brand Split Z R410A heat pump 14 Seer heat pump units. New revisions will have Sanhua (RANCO) reversing valves.

ASZ140241AF Amana® Brand Split Z R410A heat pump 14 Seer heat pump units. AF revision has the smaller B1227315 reversing valve.

ASZ140[18,30,36]1AGASZ140241AH

ASZC160[42,4860]1AF

Amana® brand Split Z Communicating heat pump, 14 Seer R410A heat pump units. Introduces Amana 14 SEER heat pumps with accumulators, crankcase heaters, and upgraded defrost control.

ASZ140361BA Amana® Brand Split Z R410A heat pump 14 Seer heat pump units. Initial release of Amana® Brand 14 SEER Heat Pump R410A, with reduced chassis size from large to medium.

ASZ140[18, 30]1AHASZ140241AJ

ASZ140[42-60]1AG

Amana® Brand Split Z R410A heat pump 14 Seer heat pump units. Relocation of low pressure switch from liquid line to suction line as a compressor safeguard to prevent low pressure from enterting.

ASZ140[18, 30]1AJASZ140241AK

ASZ140[42-60]1AHASZ140361BB

Amana® Brand Split Z R410A heat pump 14 Seer heat pump units. Initial release of models using single speed PSC motors; removal of low ambient temperature switch.

ASZ160**1AA Amana® Brand Split Z R410A heat pump 16 Seer heat pump units. Initial release of Amana® Brand 16 SEER Heat Pump R410A.

ASZ160**1AB Amana® Brand Split Z R410A heat pump 16 Seer heat pump units. Introduces new revisions have screw locations moved in the top panel, base pans, louvers, and control box covers.

ASZ160**1AC Amana® Brand Split Z R410A heat pump 16 Seer heat pump units. New revisions have horizontal style louvers.

ASZ160**1AD Amana® Brand Split Z R410A heat pump 16 Seer heat pump units. New revisions added Muffler and standardized TXV, Compensator using the ASZ18 Seer weldment.

ASZ160241ADASZ160[36-60]AE

Amana® Brand Split Z R410A heat pump 16 Seer heat pump units. Adds new steel muffler, and suction tubes w/shock loop.

ASZ160[24, 36]1AFASZ160[48, 60]1AF

Amana® Brand Split Z R410A heat pump 16 Seer heat pump units. New revisions will have Sanhua (RANCO) reversing valves.

ASZ180**1AB Amana® Brand Split Z R410A heat pump 18 Seer heat pump units. Initial release of Amana® Brand 18 SEER Heat Pump R410A.

ASZ180[36, 48, 60]1AC Amana® Brand Split Z R410A heat pump 18 Seer heat pump units. New revisions will have Sanhua (RANCO) reversing valves.

Split System Heat Pumps R410A

Page 7: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

7

Model # Description

ASZC160**1AA Amana® brand Split Z Communicating heat pump, 16 Seer R410A heat pump units. Introduces Goodman 2-stage 16 SEER heat pumps with R-410A, communicating models.

ASZC160[24, 36]1ABASZC160[48, 60]1AB

Amana® brand Split Z Communicating heat pump, 16 Seer R410A heat pump units. New revisions will have Sanhua (RANCO) reversing valves.

ASZC160[24-48]1ACASZC160601BA

Amana® brand Split Z Communicating heat pump, 16 Seer R410A heat pump units. Introduces Amana 2-stage 16 SEER heat pumps with accumulators and crankcase heaters.

ASZC180**1AA Amana® brand Split Z Communicating heat pump, 18 Seer R410A heat pump units. Introduces Goodman 2-stage 16 SEER heat pumps with R-410A, communicating models.

ASZC180[36, 48, 60]1AB Amana® brand Split Z Communicating heat pump, 18 Seer R410A heat pump units. Introduces Amana 2-stage 16 SEER heat pumps with accumulators and crankcase heaters.

ASZC180[36-48]1ACASZC180601BA

Amana® brand Split Z Communicating heat pump, 18 Seer R410A heat pump units. New revisions will have Sanhua (RANCO) reversing valves.

Split System Heat Pumps R410A

Page 8: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

8

Model # Description

GSX130**1AA Goodman Split X Condenser 13 Seer condensing units. Introduction of Goodman 13 SEER R-410A Condensers with Regal Beloit motors

GSX130**1AB Goodman Split X Condenser 13 Seer condensing units. Introduction of Goodman 13 SEER R-410A Condensers with Broad Ocean motors.

GSX130[42 & 48]1BB Goodman Split X Condenser 13 Seer condensing units. Release of models with new 6 pole motor/fan combination.

GSX130483AB Goodman Split X Condenser 13 Seer condensing units. Release of 3 phase model with new 6 pole motor.

GSX130181EAGSX130181EB

Goodman Split X Condenser 13 Seer condensing units. Introduction of 1.5 ton condenser with Rechi Compressor.

GSX130**1BAGSX130**3AAGSX130**4AA

Goodman Split X Condenser 13 Seer condensing units. Introduction of Goodman 13 SEER R-410A Condensers, using SmartCoil® coils. Units will have new louvers because units are smaller. Piston size change. Other components unchanged.

GSX130181CA Goodman Split X Condenser 13 Seer condensing units. Introduction of Goodman 1.5 ton 13 SEER R-410A Condensers with rotary compressor.

GSX130[18-36]1DA Goodman Split X Condenser 13 Seer condensing units. Introduction of Goodman 1.5 ton 13 SEER R-410A Condensers conversion to 23" chassis for the 1.5 - 3 ton models.

GSX13031DBGoodman Split X Condenser 13 Seer condensing units. Introduction of Goodman 2.5 ton units with improved coil circuit assembly for greater capacity/efficiency and the creation of a new discharge tubing assembly.

GSX14**1AA Goodman Split X 14 Seer Condensing units. Introduction of Goodman 14 SEER R-410A models.

Split System Air Conditioners R410A

Page 9: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

9

Model # Description

SSX140**1AA Special High Feature Split X Condenser 14 Seer condensing units. Initial release of Goodman 14 SEER AC 410A.

SSX140**1AB Special High Feature Split X Condenser 14 Seer condensing units. Revisions have screw locations moved in the top panel, base pans, louvers, and control box covers.

SSX14018, 241AC Special High Feature Split X Condenser 14 Seer condensing units. Revised condenser coils by removing [1] haripin.

SSX140301AC Special High Feature Split X Condenser 14 Seer condensing units. Model contains the Broad Ocean motor 0131M00060

SSX14036-601AC Special High Feature Split X Condenser 14 Seer condensing units. Models contain the Broad Ocean motor 0131M00061

SSX14030,361AD Special High Feature Split X Condenser 14 Seer condensing units. Revised condenser coils by removing [1] haripin.

SSX140[18-24]1BASSX140[30-36]1BA

SSX140421CA

Special High Feature Split X Condenser 14 Seer condensing units. Converts 1.5 - 3.5 ton condenser coil tubes from 3/8" tube diameter to 5mm tube diameter.

SSX140421BASpecial High Feature Split X Condenser 14 Seer condensing units. Revision for SSZ140421B* in 29 base pan and it will the reduce the unit charge from 180 oz. to 170 oz. and replace the 1/4 hp outdoor unit motor with 1/6 hp motor.

SSX14030-421AE Special High Feature Split X Condenser 14 Seer condensing units. Revised condenser coils by removing [1] haripin.

SSX140[18-48]1BASSX14042-481CA

Special High Feature Split X Condenser 14 Seer condensing units. Introduction of Goodman 14 SEER R-410A Condensers, using SmartCoil® Coils.

SSX140[18-36]1BBSSX140421CBSSX140601AF

Special High Feature Split X Condenser 14 Seer condensing units. Relocation of low pressure switch from liquid line to suction line as a compressor safeguard to prevent low pressure from entering.

SSX160**1AA Special High Feature Split X Condenser 16 Seer condensing units. Introduces Goodman 16 SEER AC 410A

SSX160**1AB Special High Feature Split X Condenser 16 Seer condensing units. New revisions have screw locations moved in the top panel, base pans, louvers, and control box covers.

SSX160**1ABSSX160591AA

Special High Feature Split X Condenser 16 Seer condensing units. New revisions have screw locations moved in the top panel, base pans, louvers, and control box covers.

SSX160[24, 36, 48]1BASSX160[30 & 42]1AA

Special High Feature Split X Condenser 16 Seer condensing units. New revisions have SmartCoil® coils.

SSX160601BA Special High Feature Split X Condenser 16 Seer condensing units. New "BA" revision models use ZPS49K compressor.

SSX160[24,36,60]1BBSpecial High Feature Split X Condenser 16 Seer condensing units. Relocation of low pressure switch from liquid line to suction line as a compressor safeguard to prevent low pressure from entering.

Split System Air Conditioners R410A

Page 10: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

10

Model # Description

DSX160**1AA Deluxe Split X Condenser 16 Seer condensing units. Introduces Goodman 2-stage, 16 SEER condensing units with R-410A.

DSX160[24 & 36]1BA Deluxe Split X Condenser 16 Seer condensing units. Goodman 2-stage, 16 SEER condensing units with R-410A. Conversion of 2 & 3 ton models to SmartCoil® Coils.

DSX160241BC Deluxe Split X Condenser 16 Seer condensing units. Goodman 2-stage, 16 SEER condensing units with R-410A. Introduces Ultratech® 2.0 compressor changes.

DSX180**1AA Deluxe Split X Condenser 18 Seer condensing units. Introduces Goodman 2-stage, 18 SEER condensing units with R-410A.

DSXC16**1AADeluxe Split X Communicating condensing units, 16 Seer R410A heat pump units. Introduces Goodman 2-stage 16 SEER condensing units with R-410A, communicating models.

DSXC160[24, 36]1AB Deluxe Split X Communicating condensing units, 16 Seer R410A heat pump units. New revision updates wiring diagram with notes.

DSXC160[24, 36]1AC Deluxe Split X Communicating condensing units, 16 Seer R410A heat pump units. Introduces Ultratech® 2.0 compressor changes.

DSXC160481BA Deluxe Split X Condenser 16 Seer condensing units. Goodman 2-stage, 16 SEER condensing units with R-410A, using SmartCoil® coils.

DSXC160601BADeluxe Split X Communicating condensing units, 16 Seer R410A heat pump units. Introduces Goodman 2-stage 16 SEER condensing units with R-410A, communicating models. New "BA" revison models use ZPS49K compressor.

DSXC18**1AADeluxe Split X Communicating condensing units, 18 Seer R410A condensing units. Introduces Goodman 2-stage 18 SEER condensing units with R-410A, communicating models.

DSXC180[36, 48, 60]AB Deluxe Split X Communicating condensing units, 18 Seer R410A condensing units. New revision updates wiring diagram with notes.

Split System Air Conditioners R410A

Page 11: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

11

Model # Description

VSX130[18-48]1AA Value Split X condensing units, 13 Seer R410A condensing units. Introduces Value Line 13 SEER condensing units with R-410A.

VSX130181BA Value Split X condensing units, 13 Seer R410A condensing units. Introduces Value Line 13 SEER 1.5 ton condensing units with R-410A, with rotary compressors

VSX130181EAVSX130181EB

Value Split X condensing units, 13 Seer R410A condensing units. Introduction of 1.5 ton condenser with Rechi Compressor.

VSX130241BAValue Split X condensing units, 13 Seer R410A condensing units. Introduces Value Line 13 SEER 2.0 ton condensing units with R-410A, with aluminum coils, aluminum manifolds w/existing scroll compressor.

VSX130601BA Value Split X condensing units, 13 Seer R410A condensing units. Introduces Value Line 13 SEER condensing units with R-410A, using SmartCoil® coils.

VSX130421BAVSX130481BA

Value Split X condensing units, 13 Seer R410A condensing units. Introduction of Value Line 3.5 and 4 ton 13 SEER condensing units with reciprocating compressor.

VSX130[18-36]1DAValue Split X condensing units, 13 Seer R410A condensing units. Introduction of Value Line 3.5 and 4 ton 13 SEER Condensers conversion to 23" chassis for the 1.5 - 3 ton models.

VSX130301DBValue Split X condensing units, 13 Seer R410A condensing units. Introduction of Value Line 2.5 13 SEER Condensers with improved coil circuit assembly for greater capacity/efficiency and the creation of a new discharge tubing assembly.

Split System Air Conditioners R410A

Page 12: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

12

Model # Description

ASX130**1AA Amana® Brand Split X Condenser 13 Seer condensing units. Initial release new models of Amana® Brand Deluxe 13 SEER AC R410A conditioners.

ASX130**1BAAmana® Brand Split X Condenser 13 Seer condensing units. Introduction of Amana® Brand 13 SEER R-410A Condensers, using SmartCoil® coils. Units will have new louvers since units are smaller. Piston size change; other components unchanged.

ASX130**1CBAmana® Brand Split X Condenser 13 Seer condensing units. Relocation of low pressure switch from liquid line to suction line as a compressor safeguard to prevent low pressure from entering.

ASX130181DAASX140181DA

Amana® Brand Split X Condenser 13 Seer condensing units. Initial release of models going from 2-speed fan to new 266 fan motor; removal of low pressure switch.

ASX130[24-48]1CCASX1302601CB

Amana® Brand Split X Condenser 13 Seer condensing units. Initial release of models using single speed PSC motors; removal of low pressure switch and low ambient temperature switch and relay.

ASX140**1AA Amana® Brand Split X Condenser 14 Seer condensing units. Initial release new models of Amana® Brand Deluxe 14 SEER AC R410A conditioners.

ASX140**1AB Amana® Brand Split X Condenser 14 Seer condensing units. New revisions have screw locations moved in the top panel, base pans, louvers, and control box covers.

ASX140**1AC Amana® Brand Split X Condenser 14 Seer condensing units. The new revisions have horizontal style louvers.

ASX14018-361AD Amana® Brand Split X Condenser 14 Seer condensing units. Revised condenser coils by removing (1) hairpin.Reduce R410A quantity by 6 ounces

ASX140421AD Amana® Brand Split X Condenser 14 Seer condensing units. Introduces ASX140421A in 29" base pan

ASX140421BAAmana® Brand Split X Condenser 14 Seer condensing units. Revision for ASX140421 in 29" platform. It will the reduce the unit charge from 180 oz. to 170 oz. and replace the 1/4 hp outdoor unit motor with 1/6 hp motor.

ASX140[18-30]1BAASX140[42-48]1CA

Amana® Brand Split X Condenser 14 Seer condensing units. Introduction of Amana® Brand 14 SEER R-410A Condensers, using SmartCoil® coils..

ASX140[18-36]1CBASX140421DBASX140601BB

Amana® Brand Split X Condenser 14 Seer condensing units. Relocation of low pressure switch from liquid line to suction line as a compressor safeguard to prevent low pressure from entering.

ASX140[24-36]1CCASX140421DCASX140481CBASX140601BC

Amana® Brand Split X Condenser 14 Seer condensing units. Initial release of models using single speed PSC motors; removal of low pressure switch and low ambient temperature switch and relay.

ASX160**1AB Amana® Brand Split X Condenser 16 Seer condensing units. New revisions have screw locations moved in the top panel, base pans, louvers, and control box covers.

ASX160**1AC Amana® Brand Split X Condenser 16 Seer condensing units. The new revisions have horizontal style louvers.

ASX160[24-60]1BA Amana® Brand Split X Condenser 16 Seer condensing units.New revision updates wiring diagram with notes.

ASX160[24 & 36]1CA Amana® Brand Split X Condenser 16 Seer condensing units. Introduction of 16 SEER R-410A Condensers. Conversion of 2 & 3 ton models to SmartCoil® coils.

ASX180**1AB Amana® Brand Split X Condenser 18 Seer condensing units. Initial release new models of Amana® Brand Deluxe 16 SEER AC R410A conditioners.

Split System Air Conditioners R410A

Page 13: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

13

Model # Description

ASXC160**1AA Amana® brand Split X Communicating condensing units, 16 Seer R410A. Introduces Amana® brand 2-stage 16 SEER condensing units with R-410A, communicating models.

ASXC160601BAAmana® brand Split X Communicating condensing units, 16 Seer R410A heat pump units. Introduces Amana® brand 2-stage 16 SEER condensing units with R-410A, communicating models. New "BA" revisions use ZPS49 compressor.

ASXC160481BAAmana® brand Split X Communicating condensing units, 16 Seer R410A condensing units. Introduction of Amana® brand 16 SEER condensing units with R-410A. New revisions have SmartCoil® coils

ASXC160[24, 36]1BB Amana® brand Split X Communicating condensing units, 16 Seer R410A condensing units. New revision updates wiring diagram with notes.

ASXC160[24, 36]1BC Amana® brand Split X Communicating condensing units, 16 Seer R410A condensing units. Introduces Ultratech® 2.0 compressor changes.

ASXC18**1AAAmana® brand Split X Communicating condensing units, 18 Seer R410A condensing units. Introduces Amana® brand 2-stage 16 SEER condensing units with R-410A, communicating models.

ASXC180[36, 48, 60]1AB Amana® brand Split X Communicating condensing units, 18 Seer R410A condensing units. New revision updates wiring diagram with notes.

Split System Air Conditioners R410A

Page 14: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

14

Model # Description

ARUF172916AAA24-00-2RCA

A Single Piece R Multi-Position PSC Motor Unpainted Flowrater Introduction of new Air Handler Models with all aluminum evaporator coils. Conversion includes coils, manifold, hairpin, flowrators, 3/8" return bend to 5/16" aluminum return bends.

ARUF****16AA A Single Piece R Multi-Position PSC Motor Unpainted Flowrater Introduction of new 13 SEER Air Handler Models. All Models will be suitable for use with R-22 and R-410A

ARUF364216AB A Single Piece R Multi-Position PSC Motor Unpainted Flowrater.Revision replaces the current spot welded blower housing with the same cinched or crimped design used on the 80% furnace line.

ARUF486016ABA Single Piece R Multi-Position PSC Motor Unpainted Flowrater.Revision replaces the current spot welded blower housing with the same cinched or crimped design used on the 80% furnace line.

ARUF364216AC A Single Piece R Multi-Position PSC Motor Unpainted Flowrater.Revision replaces the current spot welded blower housing with the same cinched or crimped design used on the 80% furnace line.

ARUF****16BAA Single Piece R Multi-Position PSC Motor Unpainted Flowrater. Revision replaces all ARUFcoils using wavy fin with louver enhanced fin.

ARUF****1BA A Single Piece R Multi-Position PSC Motor Unpainted Flowrater Introducation of R-22 Only Air Handlers.

ARUF****16CA A Single Piece R Multi-Position PSC Motor Unpainted Flowrater. Revision replaces existing air handler copper coils and other associated parts with aluminum components.

ARPF****16AA A Single Piece R Multi-Position PSC Motor Painted Flowrater Introducation of new 13 SEER Air Handler Models. All Models will be suitable for use with R-22 and R-410A

ARPF364216AB A Single Piece R Multi-Position PSC Motor Painted Flowrater. Revision replaces the current spot welded blower housing with the same cinched or crimped design used on the 80% furnace line.

ARPF486016AB A Single Piece R Multi-Position PSC Motor Painted Flowrater. Revision replaces the current spot welded blower housing with the same cinched or crimped design used on the 80% furnace line.

ARPF****16BAA Single Piece R Multi-Position PSC Motor Painted Flowrater. Revision replaces all ARPFcoils using wavy fin with louver enhanced fin.

ARPF****1BA A Single Piece R Multi-Position PSC Motor Painted Flowrater. Introducation of R-22 Only Air Handlers.

ARPF****16CAA Single Piece R Multi-Position PSC Motor Painted Flowrater. Revision replaces existing air handler copper coils and other associated parts with aluminum components.

ADPF****16AA A Single Piece Downflow PSC Motor Unpainted Flowrater. Introduction of new 13 SEER Air Handler Models. All Models will be suitable for use with R-22 and R-410A.

ADPF364216AB A Single Piece Downflow PSC Motor Unpainted Flowrater. Revision replaces the current spot welded blower housing with the same cinched or crimped design used on the 80% furnace line.

ADPF486016AB A Single Piece Downflow PSC Motor Unpainted Flowrater. Revision replaces the current spot welded blower housing with the same cinched or crimped design used on the 80% furnace line.

ADPF304216AC A Single Piece Downflow PSC Motor Unpainted Flowrater. Revision replaces the current spot welded blower housing with the same cinched or crimped design used on the 80% furnace line.

ADPF****1BA A Single Piece Downflow PSC Motor Unpainted Flowrater Revision replaces all ARPFcoils using wavy fin with louver enhanced fin.

ADPF182416CAADPF486016CA

A Single Piece Downflow PSC Motor Unpainted Flowrater. Revision replaces existing air handler copper coils and other associated parts with aluminum components.

Single Piece Air Handlers

Page 15: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

15

Model # Description

AEPF****16AA A Single Piece E Multi-Position Variable-Speed Painted Flowrator. Introducation of new 13 SEER Air Handler Models. All Models will be suitable for use with R-22 and R-410A

AEPF****16BA A Single Piece E Multi-Position Variable-Speed Painted Flowrator. Revision introduces new models adding lower kw hit kits on the S&R plate

AEPF****16BBA Single Piece E Multi-Position Variable-Speed Painted Flowrator. Revision replaces the current spot welded blower housing with the same cinched or crimped design used on the 80% furnace line.

AEPF****16CA A Single Piece E Multi-Position Variable-Speed Painted Flowrator. Revision replaces all ARPFcoils using wavy fin with louver enhanced fin.

AEPF****1BA A Single Piece E Multi-Position Variable-Speed Painted Flowrator Introductionof R-22 Only Air Handlers.

AEPF313716AAASPF313716AA

A Single Piece E Multi-Position Variable-Speed Painted Flowrator (AEPF) and A Single Piece S Multi-Position EEM motor Painted Flowrator (ASPF). Introduction of 3-Ton Air Handler units with 3-row coil.

ASPF****16AA A Single Piece S Multi-Position EEM motor Painted Flowrator. Introduces new ASPF Air Handlers

ASPF****16BAA Single Piece S Multi-Position EEM motor Painted Flowrator. Revision introuces modified ASPF control scheme, to ensure blower operation during and after call for heat on units with heat kits and replacing wavy fin with louver enhanced fin on coil

ASPF****16CA A Single Piece S Multi-Position EEM motor Painted Flowrator. Revision replaces existing air handler copper coils and other associated parts with aluminum components.

ASPF****16DAA Single Piece S Multi-Position EEM motor Painted Flowrator. Revision introduces and replaces Regal-Beliot X-13 motor with Emerson SelecTech motor.

ASPF****16EAA Single Piece S Multi-Position EEM motor Painted Flowrator. Revision replaces existing air handler copper coils and other associated parts with aluminum components and replaces Regal-Beliot X-13 motor with Emerson SelecTech motor.

AWUF****1AA A Single Piece Air Handler Wall Mount Unpainted Flowrator. Introduces 13 SEER Dayton wall mount air handlers

AWUF****16AAA Single Piece Air Handler Wall Mount Unpainted Flowrator. Introduces 13 SEER Dayton wall mount air handlers. All Models will be suitable for use withR-22 and R-410A

AWUF3005-101AA A Single Piece Air Handler Wall Mount Unpainted Flowrator. Introduces 13 SEER Dayton wall mount air handlers using a Burr Oak Louvered Fin coil.

AWUF****1BA A Single Piece Air Handler Wall Mount Unpainted Flowrator. Revision replaces current wavey fin design with new louvered fin design

AWUF370**16AA A Single Piece Air Handler Wall Mount Unpainted Flowrator. Introduction of AWUF37 Air Handlers for use with R-22 and R410A.

Single Piece Air Handlers

Page 16: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

16

Model # Description

AWUF****16BA A Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Revision has louver fins & replaces copper tube hairpins with aluminum hairpins.

AWUF180316BAAWUF240316BAAWUF300316BA

A Single Piece Air Handler Wall Mount Unpainted Flowrator. AWUF 3KW Heater Introduction. Introduction of 3KW heater in the AWUF air handlers

AWUF310516AAAWUF310816AA AWUF321016AA

A Single Piece Air Handler Wall Mount Unpainted Flowrator.Introduction of higher 14 SEER AWUF series air-handlers

AVPTC183014AAAVPTC313714AAAVPTC426014AA

A Single Piece V Multi-Position Variable-Speed Painted T TXV Flowrator Communicating ready w/4-wires. Introduction of new 13 SEER Air Handler Models with the new communicating control & serial communicating indoor blower motor.

ACNF****1AA A Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Revision release all models of 13 SEER Dayton uncased air handlers.

ACNF****16AAA Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Revision release all models of 13 SEER Dayton uncased air handlers.All Models will be suitable for use with R-22 and R-410A

ACNF****1AB A Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Drain pan material change.

ACNF****1BA A Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Revision replaces current wavey fin design with new louvered fin design

ACNF****16DA

A Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Conversion of existing copper coils, manifolds, hairpins, flowrators, 90° flowrator stub to aluminum. Conversion of copper 3/8" return bends to aluminum 5/16" return bends .All Models will be suitable for use with R-22 and R-410A

Single Piece Air Handlers

Page 17: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

17

Model # Description

MBR****AA-1AA Modular Blower R Multi-Position PSC Motor. Introduces module blower with PSC blower motor.

MBR****AA-1AB Modular Blower R Multi-Position PSC Motor. Quality improvement to use 0.75" Quiet Flex Insulation.

MBE****AA-1AA Modular Blower E Multi-Position Variable-Speed. Introduces module blower with variable speed blower motor.

MBE****AA-1BA Modular Blower E Multi-Position Variable-Speed.Revision introduces new models adding lower kw hit kits on the S&R plate

MBVC1200AA1-AAMBVC1600AA1-AAMBVC2000AA1-AA

Modular Blower V Multi-Position Variable-Speed Communicating ready w/4-wires. Introduction of module blower with variable speed blower motor with the new communicating control & serial communicating indoor blower motor.

MBVC1200AA1-ABMBVC1600AA1-ABMBVC2000AA1-AB

Modular Blower V Multi-Position Variable-Speed Communicating ready w/4-wires.Module blower with variable speed blower motor with communicating control & serial communicating indoor blower motor. Replaces existing Emerson motors (013M00111 & 013M00112)with 013M00270 and 013M00271.

MBVC1200AA1-ACMBVC1600AA1-ACMBVC2000AA1-AC

Modular Blower V Multi-Position Variable-Speed Communicating ready w/4-wires.Module blower with variable speed blower motor with communicating control & serial communicating indoor blower motor. Quality improvement to use 0.75" Quiet Flex Insulation.

MBR/MBE Air Handlers

Page 18: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

18

Model # Description

CAUF*****6AA C Indoor Coil A Upflow/Downflow Uncased Flowrator. Introduces 13 SEER CAUF Dayton Upflow/Downflow coils.

CAUF*****6BA C Indoor Coil A Upflow/Downflow Uncased Flowrator. Revision releases Burr Oak Louvered Fin in place of the Wavy Fin currently in production.

CAUF****6*DA C Indoor Coil A Upflow/Downflow [Painted or Uncased] Flowrator. Revision replaces existing copper coils and other associated parts with aluminum components.

CAUF*****6DB C Indoor Coil A Upflow/Downflow [Painted or Uncased] Flowrator. Drain pan material change.

CAPF*****6AA C Indoor Coil A Upflow/Downflow Painted Flowrator. Introduces 13 SEER CAPF Dayton Upflow/Downflow coils.

CAPF*****6BA C Indoor Coil A Upflow/Downflow Painted Flowrator. Revision releases Burr Oak Louvered Fin in place of the Wavy Fin currently in production.

CAPF/CAUF36***CA C Indoor Coil A Upflow/Downflow [Painted or Uncased] Flowrator. Revision redesigns for performance improvement from 2 row to 3 row.

CAPF*****6DA C Indoor Coil A Upflow/Downflow [Painted or Uncased] Flowrator. Revision replaces existing copper coils and other associated parts with aluminum components.

CAPF*****6DB C Indoor Coil A Upflow/Downflow [Painted or Uncased] Flowrator. Drain pan material change.

CHPF*****6AA C Indoor Coil Horizontal A Coil Painted Flowrator. Release 13 SEER CHPF horizontal A coil.

CHPF*****6BAC Indoor Coil Horizontal A Coil Painted Flowrator. Release 13 SEER CHPF horizontal A coil. Revision releases Burr Oak Louvered Fin in place of the Wavy Fin currently in production. The rows change by one, (i.e. 4 row to 3 row; 3 row to 2 row) where applicable.

CHPF1824A6CACHPF2430B6CACHPF3636B6CACHPF3642C6CACHPF3642D6CACHPF3743C6BACHPF3743D6BACHPF4860D6DA

C Indoor Coil Horizontal A Coil Painted Flowrator. 13 SEER CHPF horizontal A coil, revision has louver fins & replaces copper tube hairpins with aluminum hairpins.

CHPF1824A6CBCHPF2430B6CBCHPF3636B6CBCHPF3642C6CBCHPF3642D6CBCHPF3743C6BBCHPF3743D6BBCHPF4860D6DB

C Indoor Coil Horizontal A Coil Painted Flowrator. 13 SEER CHPF horizontal A coil. Drain pan material change.

Evaporator Coils

Page 19: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

19

Model # Description

CSCF*****6AA C Indoor Coil S Horizontal Slab Coil C Upainted Flowrator. Release 13 SEER CSCF slab horizontal coil.

CSCF*****6BAC Indoor Coil S Horizontal Slab Coil C Upainted Flowrator. Revision releases Burr Oak Louvered Fin in place of the Wavy Fin currently in production. The rows change by one, (i.e. 4 row to 3 row; 3 row to 2 row) where applicable.

CSCF1824N6BBCSCF3036N6BBCSCF3642N6CBCSCF4860N6CB

C Indoor Coil S Horizontal Slab Coil C Upainted Flowrator. Drain pan material change.

CSCF1824N6CACSCF3036N6CACSCF3642N6CACSCF4860N6CA

C Indoor Coil S Horizontal Slab Coil C Upainted Flowrator. Release 13 SEER CSCF slab horizontal coil. Converting copper coils, maifolds, haripins, flowrators, 90° flowrator stub and 3/8" return bends to aluminum.

CTPF*****6AA C Indoor Coil T Coated Painted Flowrator. Initial release of coated coils.

CTPF1824*6ABCTPF3030*6ABCTPF3131*6ABCTPF3636*6ACCTPF3642*6ABCTPF4860*6AB

C Indoor Coil T Coated Painted Flowrator. Drain pan material change.

CTUF1824*6AACTUF3030*6AACTUF3131*6AACTUF3636*6AACTUF3642*6AACTUF4860*6AA

C Indoor Coil T Coated Unpainted Flowrator. Initial release.

CTUF1824*6ABCTUF3030*6ABCTUF3131*6ABCTUF3636*6ACCTUF3642*6ABCTUF4860*6AB

C Indoor Coil T Coated Unpainted Flowrator. Initial release.

Evaporator Coils

Page 20: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

20

S S Z 14 36 1 A A

PRODUCT TYPE: X: Condenser R-410A Z: Heat Pump R-410A

PRODUCT FAMILY: S: Split System

SEER:SEER Rating

BRAND:G: Goodman®

(Standard Feature Set)S: Goodman® (High Feature Set)A: Amana® Brand DeluxeD: Deluxe Goodman®V: Value Line

NOMINAL CAPACITY: 018: 1.5 Tons 024: 2 Tons 030: 2.5 Tons 036: 3 Tons 042: 3.5 Tons 048: 4 Tons 059: 5 Tons 060: 5 Tons

MAJOR REVISION:A: Initial Release

MINOR REVISION:A: Initial Release

ELECTRICAL: 1: 208-230V/1ph/60Hz 3: 208-230v/3ph/60Hz 4: 460v/3ph/60Hz

Page 21: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

21

ComfortNet™

A S X C 16 024 1 A A

PRODUCT TYPE: C: Condenser R-22 H: Heat Pump R-22 X: Condenser R-410A Z: Heat Pump R-410A

PRODUCT FAMILY: S: Split System

SEER:SEER Rating

BRAND:A: Amana® Brand DeluxeD: Deluxe Goodman® MAJOR

REVISION:A: Initial Release

MINOR REVISION:A: Initial Release

ELECTRICAL: 1: 208-230V/1ph/60Hz 3: 208-230v/3ph/60Hz 4: 460v/3ph/60Hz

NOMINAL CAPACITY: 024: 2 Tons 036: 3 Tons 048: 4 Tons 060: 5 Tons

COMMUNICATION FEATURE: C: 4-wire Communication Ready

Page 22: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

22

C A P F 1824 A 6 A

PRODUCTTYPE:

C: Indoor Coil

CABINET FINISH: U: Unpainted P: Painted N: Unpainted Case

EXPANSION DEVICE:F: Flowrater

NOMINAL CAPACITY RANGE @ 13 SEER 1824: 1 1/2 to 2 Tons 3030: 2 1/2 Tons 3636: 3 Tons 3642: 3 to 3 1/2 Tons 3743: 3 to 3 1/2 Tons 4860: 4 & 5 Tons 4961: 4 & 5 Tons

REVISIONA: Revision

NOMINAL WIDTH FOR GAS FURNACE A: Fits 14" Furnace Cabinet B: Fits 17 1/2" Furnace Cabinet C: Fits 21" Furnace Cabinet D: Fits 24 1/2" Furnace Cabinet N: Does Not Apply (Horizontal Slab Coils)

APPLICATION A: Upflow/Downflow Coil H: Horizontal A Coil S: Horizontal Slab Coil T: Coated Coil

REFRIGERANT CHARGE: 6: R-410A or R-22 2: R-22 4: R-410a

Page 23: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

23

MB R 8 00 A A 1

DESIGN SERIES: MB: Modular

Blower

MOTOR TYPE: R: Constant Speed E: Variable Speed

AIRFLOW DELIVERED 08: 800 CFM 12: 1200 CFM 16: 1600 CFM 20: 2000 CFM

FACTORY HEAT 00: No Heat

ELECTRICAL SUPPLY:1: 208-230V/60hZ/1 ph

CIRCUIT BREAKER A: No Circuit Breaker B: Circuit Breaker

DESIGN SERIES A: First Series

MB V C 12 00 A A 1

DESIGN SERIES: MB: Modular Blower

MOTOR TYPE:V: Variable Speed

AIRLOW DELIVERED: 12: 1200 CFM 16: 1600 CFM 20: 2000 CFM

FACTORY HEAT: 00: No Heat

CIRCUIT BREAKER: A: No Circuit Breaker B: Circuit Breaker

DESIGN SERIES: A: First Series

ELECTRICAL SUPPLY: 1: 208-230V/60HZ/1 phase

COMMUNICATION FEATURE: C: 4-wire Communication Ready

ComfortNet™

Page 24: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

24

All Airhandlers use DIRECT DRIVE MOTORS. Power supply is AC 208-230v, 60 hz, 1 phase.

A W U F 3642 1 6 A A

PRODUCTTYPE:

A: Air Handler

CABINET FINISH: U: Unpainted P: Painted N: Uncased

EXPANSION DEVICE: F: Flowrater T: TXV (Expansion Device)

Ceiling Mount & Wall Mount Applications (Nominal Cooling Capacity/Electric Heat kW) 1803: 1 1/2 Tons Cooling / 3 kW Electric Heat 1805: 1 1/2 Tons Cooling / 5 kW Electric Heat 2405: 2 Tons Cooling / 5 kW Electric Heat 3608: 3 Tons Cooling / 8 kW Electric Heat 3105: 1.5 - 2.5 Tons Cooling / 5kW Electric Heat 3210: 2 - 2.5 Tons Cooling / 10kW Electric Heat 3705: 3 Tons Cooling / 5 kW Electric Heat 3708: 3 Tons Cooling / 8 kW Electric Heat 3710: 3 Tons Cooling / 10 kW Electric Heat

MAJOR REVISION*

MINOR REVISION*

ELECTRICAL: 1: 208-230V/1ph/60Hz

APPLICATION C: Ceiling Mount PSC Motor D: Downflow PSC Motor E: Multi-Position Varible Speed Motor S: Energy-Efficient Motor R: Multi-Position PSC Motor T: Coated Coils W: Wall Mount PSC Motor

REFRIGERANT CHARGE: No Digit: R-22 Only 6: R-410A or R-22

NOMINAL CAPACITY RANGE: @ 13 SEER Dedicated Application 3636: 3 Tons

Multi-Position & Downflow Applications 3137: 3 Tons 3642: 3 - 3 1/2 Tons 1830: 1 1/2 - 3 1/2 Tons @10 SEER 1729: 1 1/2 - 2 1/2 Tons (for export systems)

Page 25: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

25

All Airhandlers use DIRECT DRIVE MOTORS. Power supply is AC 208-230v, 60 hz, 1 phase.

A V P T C 1830 1 6 A A

PRODUCTTYPE:

A: Air Handler

CABINET FINISH: U: Unpainted P: Painted N: Uncased

EXPANSION DEVICE: F: Flowrater T: TXV (Expansion Device)

NOMINAL CAPACITY RANGE: Multi-Position & Downflow Applications 3137: 3 Tons 1830: 1 1/2 - 2 1/2 Tons Ceiling Mount & Wall Mount Applications (Nominal Cooling Capacity/Electric Heat kW ) 4260: 3 1/2 Tons - 5 Tons

MAJOR REVISION*

MINOR REVISION*

ELECTRICAL: 1: 208-230V/1ph/60Hz

MOTOR SPEEDV: Variable Speed

REFRIGERANT CHARGE: No Digit: R-22 Only 6: R-410A or R-22

COMMUNICATION FEATURE: C: 4-wire Communication Ready

ComfortNet™

Page 26: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

26

LIGHT COMMERCIAL

Model # Description

GSX11090*AAGSX11120*AA

Goodman Split X Condenser 11 Seer condensing units. Introduction of Goodman Light Commercial 11 SEER, R-410A Condensers.

GSX111203ABGSX110903ABGSX111204ABGSX110904AB

Goodman Split X Condenser 11 Seer, 208-230V and 460V 3 Phase condensing units with new ball valve/brackets, suction tube/assembly and panel w/offset.

Model # Description

GSZ11090*AAGSZ11120*AA

Goodman Split Z R410A Heat Pump 11 Seer R410A heat pump units. Introduction of Goodman Light Commercial 11 SEER, R-410A Heat Pumps.

GSZ110903ABGSZ111203ABGSZ110904ABGSZ111204AB

Goodman Split Z R410A Heat Pump 11 Seer, 208-230V and 460V 3 Phase R410A heat pump units with new ball valve/brackets, suction tube/assembly and panel w/offset.

Model # Description

AR0904AAR1204A

A Single Piece R Multi-Position PSC Motor. Introducation of new 7.5 & 10 Ton Air Handler Models, for use with GSX11 and GSZ11 Light Commercial Models.

Split System Air Conditioners R410A - LIGHT COMMERCIAL

Split System Heat Pumps R410A - LIGHT COMMERCIAL

Single Piece Air Handlers - LIGHT COMMERCIAL

Page 27: Service Manual - R410a - RS6200006R32[1]

PRODUCT IDENTIFICATION

27

AR Nominal Cooling Capacity

Model SeriesAR

0904 - 90,000 Btuh (7 1/2 Tons)

1204 - 120,000 Btuh (10 Tons)

LIGHT COMMERCIAL

For use with GSX/GSZ11 Light Commercial models only.

GSZ110903AAGSZ110904AAGSZ111203AAGSZ111204AA

G S X 11 090 3 A A

PRODUCT TYPE: X: Condenser R-410A Z: Heat Pump R-410A

PRODUCT FAMILY: S: Split System

SEER:SEER Rating

BRAND:G: Goodman®

(Standard Feature Set)

NOMINAL CAPACITY: 090: 7.5 Tons 120: 10 Tons

MAJOR REVISION:A: Initial Release

MINOR REVISION:A: Initial Release

ELECTRICAL: 3: 208-230v/3ph/60Hz 4: 460v/3ph/60Hz

Page 28: Service Manual - R410a - RS6200006R32[1]

ACCESSORIES

28

LIGHT COMMERCIALGSX11

GSZ11

NOTES:

• AR Series Air Handlers do not have factory installed electric heat. Purchased as an accessory, these are the ONLYheater kits that can be used with the AR Series.

• The electrical characteristics of the air handler, electric heater kits and building power supply must be compatible.

AHKDModel

NominalkW

ElectricalCharacteristics Stages Weight

(lbs.)

Max.OvercurrentProtection

AHKD15-3 15 208-230/3/60 1 56 60AHKD15-4 15 460/3/60 1 55 30AHKD20-3 20 208-230/3/60 2 59 70AHKD20-4 20 460/3/60 2 57 35AHKD30-3 30 208-230/3/60 2 60 100AHKD30-4 30 460/3/60 2 58 50

ELECTRIC HEATER KITS

Model Description GSX110903 GSX110904 GSX111203 GSX111204

FSK01A* Freeze Protection Kit x x x x

ASC01 Anti Short Cycle Kit x x x xLAKT-01 Low Ambient Kit x x x xLSK03* Liquid Line Solenoid Kit x x x x

Model Description GSZ110903 GSZ110904 GSZ111203 GSZ111204

FSK01A* Freeze Protection Kit x x x xASC01 Anti Short Cycle Kit x x x x

OT-EHR18-60 Emergency Heat Relay Kit --- --- --- ---LAKT-01 Low Ambient Kit x x x xLSK03* Liquid Line Solenoid Kit x x x x

Page 29: Service Manual - R410a - RS6200006R32[1]

29

ACCESSORIESASX13

Model DescriptionASX13018*

ASX13024*

ASX13030*

ASX13036*

ASX13042*

ASX13048*

ASX13060*

ABK-201 Anchor Bracket Kit X X X X X X X

ASC01 Anti-Short Cycle Kit X X X X X X X

CSR-U-1 Hard-start Kit X X X X

CSR-U-2 Hard-start Kit X X

CSR-U-3 Hard-start Kit X X

FSK01A2 Freeze Protection Kit X X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X X

TX2N4A³ TXV Kit X X

TX3N43 TXV Kit X X

TX5N43 TXV Kit X X X

GSX13

Model DescriptionGSX13018*

GSX13024*

GSX13030*

GSX13036*

GSX13042*

GSX13048*

GSX13060*

ABK-201 Anchor Bracket Kit X X X X X X X

ASC01 Anti-Short Cycle Kit X X X X X X X

CSR-U-1 Hard-start Kit X X X X

CSR-U-2 Hard-start Kit X X

CSR-U-3 Hard-start Kit X X

FSK01A1 Freeze Protection Kit X X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X X

TX2N4A³ TXV Kit X X

TX3N42 TXV Kit X X

TX5N42 TXV Kit X X X

CSB-15 Sound Blanket Kit X X X

CSB-16 Sound Blanket Kit X X X X

GSX13 Three-phase models

Model DescriptionGSX130363*

GSX130483*

GSX130484*

GSX130603*

GSX130604*

ABK-201 Anchor Bracket Kit X X X X X

ASC01 Anti-Short Cycle Kit X X X X X

FSK01A2 Freeze Protection Kit X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X

TX3N43 TXV Kit X

TX5N43 TXV Kit X X X X

CSB-15 Sound Blanket Kit X X X X

CSB-16 Sound Blanket Kit X

LAKT01 Low Ambient Kit X X X X X

0163R00002 Crankcase Heater Kit X

0163R00003 Crankcase Heater Kit X X

0163R00004 Crankcase Heater Kit X X1 Contains 20 brackets; four brackets needed to anchor unit to pad2 Installed on indoor coil3 Field-installed, non-bleed, expansion valve kit — Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigera

Page 30: Service Manual - R410a - RS6200006R32[1]

ACCESSORIES

30

ASX14

Model DescriptionASX14018

ASX14024

ASX14030

ASX14036

ASX14042

ASX14048

ASX14060

ABK-201 Anchor Bracket Kit X X X X X X X

ASC01 Anti-Short Cycle Kit X X X X X X X

CSR-U-1 Hard-start Kit X X X X

CSR-U-2 Hard-start Kit X X

CSR-U-3 Hard-start Kit X X

FSK01A1Freeze Protection Kit X X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X X

TX2N4A TXV Kit X X

TX3N4 TXV Kit X X

TX5N4 TXV Kit X X X

GSX14

Model DescriptionGSX14018

GSX14024

GSX14030

GSX14036

GSX14042

GSX14048

GSX14060

ABK-201 Anchor Bracket Kit X X X X X X X

ASC01 Anti-Short Cycle Kit X X X X X X XCSR-U-1 Hard-start Kit X X X X

CSR-U-2 Hard-start Kit X XCSR-U-3 Hard-start Kit X XFSK01A1

Freeze Protection Kit X X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X XTX2N4A TXV Kit X XTX3N4 TXV Kit X XTX5N4 TXV Kit X X X

CSB-14 Sound Blanket Kit X XCSB-16 Sound Blanket Kit X X X X X

SSX14

Model DescriptionSSX14018

SSX14024

SSX14030

SSX14036

SSX14042

SSX14048

SSX14060

ABK-201 Anchor Bracket Kit X X X X X X X

ASC01 Anti-Short Cycle Kit X X X X X X X

CSR-U-1 Hard-start Kit X X X X

CSR-U-2 Hard-start Kit X X

CSR-U-3 Hard-start Kit X X

FSK01A1 Freeze Protection Kit X X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X X

TX2N4A TXV Kit X X

TX3N42 TXV Kit X X

TX5N42 TXV Kit X X X

1 Installed on indoor coil

2 Require for heat pump applications where ambient temperatures fall below 0°F with 50% or higher relative humidy.

Page 31: Service Manual - R410a - RS6200006R32[1]

31

ACCESSORIESSSX16

Model DescriptionSSX16024*

SSX16030*

SSX16036*

SSX16042*

SSX16048*

SSX16060*

ABK-201 Anchor Bracket Kit X X X X X X

ASC01 Anti-Short Cycle Kit X X X X X X

CSR-U-1 Hard-start Kit X X X

CSR-U-2 Hard-start Kit X X

CSR-U-3 Hard-start Kit X XFSK01A1

Freeze Protection Kit X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X

TX2N4A TXV Kit X

TX3N4 TXV Kit X X

TX5N4 TXV Kit X X X1 Installed on indoor coil

ASX16/DSX16

Model DescriptionA/DSX16

024*A/DSX16

030*A/DSX16

036*A/DSX16

042*A/DSX16

048*A/DSX16

060*

ABK-201 Anchor Bracket Kit X X X X X X

ASC01 Anti-Short Cycle Kit X X X X X X

CSR-U-1 Hard-start Kit X X X

CSR-U-2 Hard-start Kit X X

CSR-U-3 Hard-start Kit X XFSK01A1

Freeze Protection Kit X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X

TX2N4A TXV Kit X

TX3N4 TXV Kit X X

TX5N4 TXV Kit X X X1 Installed on indoor coil

2 Required for heat pump applications where ambient temperatures fall below 0°F with 50% or higher relative humidy.

2 Required for heat pump applications where ambient temperatures fall below 0°F with 50% or higher relative humidy.

Page 32: Service Manual - R410a - RS6200006R32[1]

ACCESSORIES

32

ASX/DSX18

Model DescriptionA/DSX18

036*A/DSX18

048*/DSX18060*

ABK-201 Anchor Bracket Kit X X X

ASC01 Anti-Short Cycle Kit X X X

CSR-U-1 Hard-start Kit X

CSR-U-2 Hard-start Kit X

CSR-U-3 Hard-start Kit X X

FSK01A1Freeze Protection Kit X X X

LSK02A Liquid Line Solenoid Kit X X X

TX2N4A TXV Kit

TX3N4 TXV Kit X

TX5N4 TXV Kit X X

1 Installed on indoor coil2 Required for heat pump applications where ambient temperatures fall below 0°F with 50% or higher relative humidy.

Page 33: Service Manual - R410a - RS6200006R32[1]

33

ACCESSORIES ComfortNet™

Model DescriptionASXC16024DSXC16024

ASXC16036DSXC16036

ASXC16048DSXC16048

ASXC16060DSXC16060

ASXC18036DSXC18036

ASXC18048DSXC18048

ASXC18060DSXC18060

ABK-20 Anchor Bracket Kit X X X X X X X

TX2N4A TXV Kit XTX3N4 TXV Kit X XTX5N4 TXV Kit X X X X

CSR-U-1 Hard-start Kit X X X

CSR-U-2 Hard-start Kit X

CSR-U-3 Hard-start Kit X X X X

FSK01A 1 Freeze Protection Kit X X X X X X X

LSK02/03ALiquid Line Solenoid Valve

X X X X X X X

B1141643 3 24V Transformer X X X X X X X

* * Contains 20 brackets; four brackets needed to anchor unit to pad.1 Installed on the indoor coil.2 Available in 24V legacy mode only. This feature is integrated in the communicating mode.3 This component is included in the CTK0*** communicating thermostat kit.

ASXC/DSXC 16ASXC/DSXC 18

Page 34: Service Manual - R410a - RS6200006R32[1]

ACCESSORIES

34

ASZ13

Model DescriptionASZ13018

ASZ13024

ASZ13030

ASZ13036

ASZ13042

ASZ13048

ASZ13060

AFE18-60A All-Fuel Kit X X X X X X X

ASC01 Anti-Short Cycle Kit X X X X X X X

CSR-U-14 Hard-start Kit X X X X

CSR-U-24 Hard-start Kit X X

CSR-U-34 Hard-start Kit X X

FSK01A2 Freeze Protection Kit X X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X X

OT/EHR18-60 Emergency Heat Relay kit X X X X X X X

OT18-60A3 Outdoor Thermostat w/Lockout Stat X X X X X X X

TX2N4A4 TXV Kit X X

TX3N44 TXV Kit X X

TX5N44 TXV Kit X X X

GSZ13

Model DescriptionGSZ13018

GSZ13024

GSZ13030

GSZ13036

GSZ13042

GSZ13048

GSZ13060

AFE18-60A All-Fuel Kit X X X X X X X

ASC01 Anti-Short Cycle Kit X X X X X X X

CSB-15 Sound Blanket X X X

CSB-16 Sound Blanket X X X X

CSR-U-14 Hard-start Kit X X X X

CSR-U-24 Hard-start Kit X X

CSR-U-34 Hard-start Kit X X

FSK01A2 Freeze Protection Kit X X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X X

OT/EHR18-60 Emergency Heat Relay kit X X X X X X X

OT18-60A3 Outdoor Thermostat w/Lockout Stat X X X X X X X

TX2N4A5 TXV Kit X X

TX3N45 TXV Kit X X

TX5N45 TXV Kit X X X

GSZ13 Three-phase models

Model DescriptionGSZ13036*

GSZ13048*

GSZ13048*

GSZ13060*

GSZ13060*

AFE18-60A All-Fuel Kit X X X X X

ASC01 Anti-Short Cycle Kit X X X X X

FSK01A2 Freeze Protection Kit X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X

OT/EHR18-60 Emergency Heat Relay kit X X X X X

OT18-60A3 Outdoor Thermostat w/Lockout Stat X X X X X

TX3N45 TXV Kit X X

TX5N45 TXV Kit X X X

CSB-15 Sound Blanket Kit X X X X

CSB-16 Sound Blanket Kit X

LAKT01 Low Ambient Kit X X X X X

1 Contains 20 brackets; four bracketsneeded to anchor unit to pad

2 Installed on indoor coil.

3 Required for heat pump applicationswhere ambient temperatures fall below0°F with 50% or higher relative humid-ity.

4 Condensing units & heat pumps with re-ciprocating compressors require the useof start-assist components when used inconjuntion with an indoor coil using a non-bleed expansion valve refrigerant me-tering device.

5 Field-installed, non-bleed, expansionvalve kit - Condensing units and heatpumps with reciprocating compressorsrequire the use of start-assist compo-nents when used in conjuntion with anindoor coil using a non-bleed thermal ex-pansion valve refrigerant.

Page 35: Service Manual - R410a - RS6200006R32[1]

35

ACCESSORIESSSZ14

Model DescriptionSSZ14018*

SSZ14024*

SSZ14030*

SSZ14036*

SSZ14042*

SSZ14048*

SSZ14060*

AFE18-60A All-Fuel Kit X X X X X X X

CSR-U-1 Hard-start Kit X X X X

CSR-U-2 Hard-start Kit X X

CSR-U-3 Hard-start Kit X X

FSK01A1 Freeze Protection Kit X X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X X

OT18-60A2 Outdoor Thermostat X X X X X X X

OT/EHR18-60 Emergency Heat Relat Kit X X X X X X X

TX2N4A³ TXV Kit X X

TX3N4³ TXV Kit X X

TX5N4³ TXV Kit X X X

ASZ14

Model DescriptionASZ14018*

ASZ14024*

ASZ14030*

ASZ14036*

ASZ14042*

ASZ14048*

ASZ14060*

AFE18-60A All-Fuel Kit X X X X X X X

CSR-U-1 Hard-start Kit X X X X

CSR-U-2 Hard-start Kit X X

CSR-U-3 Hard-start Kit X X

FSK01A1 Freeze Protection Kit X X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X X

OT18-60A2 Outdoor Thermostat X X X X X X X

OT/EHR18-60 Emergency Heat Relat Kit X X X X X X X

TX2N4A³ TXV Kit X X

TX3N4³ TXV Kit X X

TX5N4³ TXV Kit X X X

GSZ14

Model DescriptionGSZ14018*

GSZ14024*

GSZ14030*

GSZ14036*

GSZ14042*

GSZ14048*

GSZ14060*

AFE18-60A All-Fuel Kit X X X X X X X

CSR-U-1 Hard-start Kit X X X X

CSR-U-2 Hard-start Kit X X

CSR-U-3 Hard-start Kit X X

FSK01A1 Freeze Protection Kit X X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X X

OT18-60A2 Outdoor Thermostat X X X X X X X

OT/EHR18-60 Emergency Heat Relat Kit X X X X X X X

TX2N4A³ TXV Kit X X

TX3N4³ TXV Kit X X

TX5N4³ TXV Kit X X XCSB-15 Sound Blanket Kit X X XCSB-16 Sound Blanket Kit X X X X1 Installed on indoor coil2 Required for heat pump applications where ambient temperatures fall below 0°F with 50% or higher relative humidy.

Page 36: Service Manual - R410a - RS6200006R32[1]

ACCESSORIES

36

ASZ16/DSZ16

Model DescriptionA/DSZ16

024*A/DSZ16

030*A/DSZ16

036*A/DSZ16

042*A/DSZ16

048*A/DSZ16

060*

AFE18-60A All-Fuel Kit X X X X X X

CSR-U-1 Hard-start Kit X X X

CSR-U-2 Hard-start Kit X X

CSR-U-3 Hard-start Kit X X

FSK01A1 Freeze Protection Kit X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X

OT/EHR18-60 Emergency Heat Relay Kit X X X X X X

OT18-60A² Outdoor Thermostat w/ Lockout Stat X X X X X X

TX2N4A TXV Kit X

TX3N4 TXV Kit X X

TX5N4 TXV Kit X X X

SSZ16

Model DescriptionSSZ16024*

SSZ16030*

SSZ16036*

SSZ16042*

SSZ16048*

SSZ16060*

AFE18-60A All-Fuel Kit X X X X X X

CSR-U-1 Hard-start Kit X X X

CSR-U-2 Hard-start Kit X X X X

CSR-U-3 Hard-start Kit X X

FSK01A1 Freeze Protection Kit X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X

OT/EHR18-60 Emergency Heat Relay Kit X X X X X X

OT18-60A² Outdoor Thermostat w/ Lockout Stat X X X X X X

TX2N4A TXV Kit X

TX3N4 TXV Kit X X

TX5N4 TXV Kit X X X

1 Installed on indoor coil2 Required for heat pump applications where ambient temperatures fall below 0°F with 50% or higher relative humidy.

1 Installed on indoor coil2 Required for heat pump applications where ambient temperatures fall below 0°F with 50% or higher relative humidy.

Page 37: Service Manual - R410a - RS6200006R32[1]

37

ACCESSORIESASZ/DSZ18

Model DescriptionA/DSZ18

036*A/DSZ18

048*A/DSZ18

060*

AFE18-60A All-Fuel Kit X X X

CSR-U-1 Hard-start Kit X

CSR-U-2 Hard-start Kit X

CSR-U-3 Hard-start Kit X X

FSK01A1 Freeze Protection Kit X X X

LSK02A Liquid Line Solenoid Kit X X X

OT/EHR18-60 Emergency Heat Relay Kit X X X

OT18-60A² Outdoor Thermostat w/ Lockout Stat X X X

TX2N4A³ TXV Kit

TX3N4³ TXV Kit X

TX5N4³ TXV Kit X X

1 Installed on indoor coil

2 Require for heat pump applications where ambient temperatures fall below 0°F with 50% or higher relative humidy.

³ Field-installed, non-bleed, expansion valve kit — Condensing units and heat pumps with reciprocating compressors requir

start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device.

Page 38: Service Manual - R410a - RS6200006R32[1]

ACCESSORIES

38

ComfortNet™

Model Description ASZC16024DSZC16024

ASZC16036DSZC16036

ASZC16048DSZC16048

ASZC16060DSZC16060

ASZC18036DSZC18036

ASZC18048DSZC18048

ASZC18060DSZC18060

TX2N4A 1 TXV Kit X

TX3N4 1 TXV Kit X X

TX5N4 1 TXV Kit X X X X

CSR-U-1 Hard-start Kit X X X

CSR-U-2 Hard-start Kit X X

CSR-U-3 Hard-start Kit X X X X

FSK01A 2 Freeze P rotection Kit X X X X X X X

LSK02A Liquid Line Solenoid Kit X X X X X X X

OT18-60A 3 Outdoor Thermostat/ Lockout Thermostat X X X X X X X

B1141643 4 24V Transformer X X X X X X X

* Contains 20 brackets; four brackets needed to anchor unit to pad1

2 Installed on the indoor coil3

4 This component is included in the CTK0* communicating thermos tat kit.

Field-ins talled, non-bleed, expansion valve kit - Condens ing units and heap pumps with reciprocating c ompressors require the use of start-as sist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant

Available in 24V legacy mode only. This feature is integrated in the communicating mode. Required for heat pump applications where ambient temperature fall below 0 °F with 50% or higher relative humidity.

ASZC/DSZC16ASZC/DSZC18

Page 39: Service Manual - R410a - RS6200006R32[1]

39

ACCESSORIES

SUCTION LINE

BULB

1/4 FLARE CONNECTION

EXPANSION VALVE

EVAPORATOR COIL

REMOVE BEFORE INSTALLING EXPANSION VALVE

SEAL SUPPLIED W/ KIT

SEAL SUPPLIED W/ KIT

BULB TO BE LOCATEDAT 10 OR 2 O'CLOCK

For Applications requiringa field installed access fitting

TAILPIECE

3/8"-SWEAT

7/8" NUT

DISTRIBUTORBODY

PISTON SEAL

EVAPORATOR COIL

1/4' FLARECONNECTION

BULB SUCTION LINE

EXPANSION VALVE

REMOVE BEFOREINSTALLINGEXPANSION VALVE SEAL SUPPLIED W/ KIT

SEAL SUPPLIED W/ KIT

BULB TO BE LOCATEDAT 10 OR 2 O'CLOCK

TAILPIECE

3/8"-SWEAT

7/8" NUT

DISTRIBUTORBODY

PISTON SEAL

For Applications not requiringa field installed access fitting

EXPANSION VALVE KITS

OT/EHR18-60OUTDOOR THERMOSTAT &EMERGENCY HEAT RELAY

Set Point Adjustment

Screw Set PointIndicator

Mark(Shown @ Oº F)

ThermostatDial

DEADDIAL

315º

45º

COLD (Turn Clockwise)

WARM (Turn Counterclockwise)

OT18-60

Not for use withComfortNet System

Page 40: Service Manual - R410a - RS6200006R32[1]

ACCESSORIES

40

FSK01AFREEZE THERMOSTAT

KIT

T2 T1

L2 L1

BLACK 1

THERMOSTATWIRE

SHORT CYCLEPROTECTOR

YELLOW 1

BLACK 1

Y1Y2

R1R2

Y

CUNIT

TERMINALBOARD

CONTACTOR

ASC01AANTI-SHORT -CYCLE CONTROL KIT

Install LineThermostat

Here

Install LineThermostat

Here

Wire Nut

Wire Nut

YY

Blac

kBlac

k

Wire Nut

Y

Wire Nut YBlack

Black

Not for use withComfortNet System

Page 41: Service Manual - R410a - RS6200006R32[1]

41

ACCESSORIESCOIL ACCESSORIES

HKR SERIES ELECTRIC HEAT KITSELECTRIC HEAT KIT APPLICATIONS - MBR, MBE, MBVC

NO HEAT HKR-03* HKR05-(C)' HKR-06* HKR-08(C)* HKR-10(C)* HKR-15(C)* HKR-20(C)* HKR-21(C)* ^HKR3-15* HKR3-20A

MBR0800AA-1AA - X X X X X

MBR1200AA-1AA - X X X X X X X X X X

MBR1600AA-1AA - X X X X X X X X X X

MBR2000AA-1AA - X X X X X X X X X X

MBE1200AA-1AA - - - - X X X - - - -

MBE1600AA-1AA - - - - - X X - - - -

MBE2000AA-1AA - - - - - X X X - - -

MBE1200AA-1BA - X X X X X X - - - -

MBE1600AA-1BA - X X X X X X - - - -

MBE2000AA-1AA - X X X X X X X - - -

MBVC1200AA-1** - X X X X X X - - - -

MBVC1600AA-1** - X X X X X X - - - -

MBVC2000AA-1** - X X X X X X X - - -

X = Allowable combinations = Circuit 1: Single Phase for Air Handler Motor * = Revision level that my or may not be designated- = Restricted combinations Circuit 2: 3-Phase for HKR3 Heater Kits C = Circuit Breaker option

BLOWERELECTRIC HEAT KIT

COIL MODEL TX2N4A TXV KIT TX3N4 TXV KIT TX5N4 TXV KIT FSK01A FREEZE PROTECTION KIT

CA*F18246* X XCA*F30306* X X

CA*F31316* X XCA*F36366* X X

CA*F36426* X X XCA*F37436* X X X

CA*F48606* X XCA*F49616* X X

CHPF18246* X XCHPF24306* X X

CHPF36366* X XCHPF36426* X X

CHPF37436* X X X

CHPF48606* X XCSCF1824N6* X X

CSCF3036N6* X XCSCF3642N6* X X X

CSCF4860N6* X X

Page 42: Service Manual - R410a - RS6200006R32[1]

ACCESSORIES

42

ELECTRIC HEAT KIT APPLICATIONS - ARUF

ELECTRIC HEAT KIT APPLICATIONS - ARPFARPF1824

1/16ARPF1931

1/16ARPF3030

1/16ARPF3642

1/16ARPF3743

1/16ARPF4860

1/16HKR-03* X X X X X XHKR-05*, HKR-05C* X X X X X XHKR-06* X X X X X XHKR-08*, HKR-08C* X1 X1 X X X XHKR-10*, HKR-10C* X1 X1 X1 X X XHKR-15C* X2 X2 X2 X3 X3 XHKR-20C* X2 X3 X3 XHKR-21C* X2 X3 X3 X HKR3-15* X2 X3 X3 X HKR3-20* X2 X3 X3 X

* Revision level that may or may not be designatedC Circuit breaker option Heat kit required three-phase power supply

1 Air handler must either be on medium or high speed2 Air handler must be on high speed3 For static pressure of 0.6 or higher, air handler must be on medium or high speed.

ARUF1729 1/16

ARUF1824 1/16

ARUF1931 1/16

ARUF3030 1/16

ARUF3642 1/16

ARUF3743 1/16

ARUF4860 1/16

HKR-03* X X X X X X X

HKR-05*, HKR-05C* X X X X X X X

HKR-06* X X X X X X X

HKR-08*, HKR-08C* X1 X1 X1 X X X X

HKR-10*, HKR-10C* X1 X1 X1 X1 X X X

HKR-15C* X2 X2 X2 X2 X3 X3 X

HKR-20C* X2 X3 X3 X

HKR-21C* X2 X3 X3 X

^ HKR3-15* X2 X3 X3 X

^ HKR3-20* X2 X3 X3 X

* Revision level that may or may not be designatedC Circuit breaker option^ Heat kit required three-phase power supply1 Air handler must either be on medium or high speed2 Air handler must be on high speed3 For static pressure of 0.6 or higher, air handler must be on medium or high speed.

Page 43: Service Manual - R410a - RS6200006R32[1]

43

ACCESSORIES

ELECTRIC HEAT KIT APPLICATIONS - AVPT

MODELS HKR-03* HKR-05*/-05C* HKR-06* HKR-08*/-08C* HKR-10*/-10C* HKR-15C HKR-20C HKR-21C

AVPTC183014A* X X X X1 X1 --- --- ---AVPTC313714A* X X X X1 X1 X2 --- ---AVPTC426014A* X X X X X X X3 X3

* Revision level that may or may not be designated.

C Circuit breaker option.

NOTE:

When 8kW and 10kW heat kits are used with an AVPTC1830 and AVPTC3137, matched with 2- ton outdoor unit, see Note 1 below.1 Set Heater Kit dip switches 9, 10 and 11 to 6kW setting (9-ON, 10-OFF,11-ON) to obtain 840 CFM.2 This heater kit can only be used for ‘1000 CFM or higher’ applications.3 This heater kit can only be used for ‘1200 CFM or higher’ applications.

AEPF183016 AEPF303616 AEPF313716 AEPF426016

HKR-05*, HKR-05C* X X

HRK-08*, HKR-08C X X X

HKR-10*, HKR-10C X1 X X X

HKR-15C* X1 X1 X

HKR-20C* X2

HKR-21C X2

* Revision level that may or may not be designatedC Circuit Breaker option1 This heater kit can be used ONLY for 1000 CFM or higher applications2 This heater kit can be used ONLY for 1200 CFM or higher applications

ELECTRIC HEAT KIT APPLICATIONS - AEPF

Page 44: Service Manual - R410a - RS6200006R32[1]

ACCESSORIES

44

ELECTRIC HEAT KIT APPLICATIONS - ASPF

ASPF183016 ASPF303616 ASPF313716 ASPF426016

HKR-03* X X X X

HKR-05*, HKR-05C* X X X X

HKR-06* X X X X

HRK-08*, HKR-08C* X1 X1 X1 X

HKR-10*, HKR-10C* X1 X1 X1 X

HKR-15C* X2 X2 X2 X1

HKR-20C* X2 X2 X1

HKR-21C* X2 X2

+HKR3-15* X2 X2 X2 X1

+HKR3-20* X2 X2 X1

* Revision level that may or may not be designatedC Circuit Breaker option+ Heat kit requires 3-phase power supply1 Air handler must be on speed tap 2, 3, 4 or 52 Air handler must be on speed tap 4 or 53 Air handler must be on speed tap 3, 4 or 5

Page 45: Service Manual - R410a - RS6200006R32[1]

PRODUCT DESIGN

45

This section gives a basic description of cooling unit opera-tion, its various components and their basic operation.Ensure your system is properly sized for heat gain and lossaccording to methods of the Air Conditioning ContractorsAssociation (ACCA) or equivalent.

CONDENSING UNITThe condenser air is pulled through the condenser coil by adirect drive propeller fan. This condenser air is then dis-charged out of the top of the cabinet. These units aredesigned for free air discharge, so no additional resistance,like duct work, shall be attached.The suction and liquid line connections on present modelsare of the sweat type for field piping with refrigerant typecopper. Front seating valves are factory installed to acceptthe field run copper. The total refrigerant charge for a normalinstallation is factory installed in the condensing unit.GSX, GSZ, ASX, ASZ, SSX, SSZ, DSX, DSZ, VSX, and VSZmodels are available in 1 1/2 through 5 ton sizes and use R-410A refrigerant. They are designed for 208/230 volt singlephase applications.GSX/GSZ *****3 models are available in 3, 4, and 5 ton sizesand use R-410A refrigerant. They are designed for 208/230volt 3-phase applications.GSX/GSZ *****4 models are available in 4 and 5 ton sizes anduse R-410A refrigerant. They are designed for 460 volt 3-phase applications.ASX, ASZ, DSX and DSZ R-410A model units use theCopeland Scroll "Ultratech" Series compressors which arespecifically designed for R-410A refrigerant. These units alsohave Copeland® ComfortAlert diagnostics.GSX, GSZ, SSX, SSZ, VSX, and VSZ R-410A model units,except for GSX130181C*, VSX130181B*, VSX130421B*,and VSX130481B*, use the Copeland Scroll "Ultratech"Series compressors which are specifically designed for R-410A refrigerant.ASXC, ASZC, DSXC, DSZC models are available in 2through 5 ton sizes and use R-410A refrigerant. They aredesigned for 208/230 volt single phase applications.ASXC, ASZC, DSXC, DSZC R-410A model units use theCopeland Scroll "Ultratech" Series compressors which arespecifically designed for R-410A refrigerant. These units alsohave Copeland® ComfortAlert diagnostics. The Copeland®

ComfortAlert diagnostics are integrated into the unitary (UC)control. These models are ComfortNetTM ready.There are a number of design characteristics which aredifferent from the traditional reciprocating and/or scroll com-pressors."Ultractech" Series scroll compressors will not have a dis-charge thermostat. Some of the early model scroll compres-sors required discharge thermostat."Ultratech" Series scroll compressors use "POE" orpolyolester oil which is NOT compatible with mineral oilbased lubricants like 3GS. "POE" oil must be used ifadditional oil is required.

COILS AND BLOWER COILS - LEGACYMODELSMBR/MBE/MBVC blower cabinets are designed to be usedas a two-piece blower and coil combination. MBR/MBE/MBVC blower sections can be attached to cased evaporatorcoil. This two-piece arrangement allows for a variety of mix-matching possibilities providing greater flexibility. The MBE/MBVC blower cabinets use a variable speed motor thatmaintains a constant airflow with a higher duct static.MBE/MBVC blower cabinests are approved for applicationswith cooling coils of up to 0.8 inches W.C. external staticpressure. The MBE models includes a feature that allowsairflow to be changed by +10% or -15%. The MBVC modelsallow airflow trimming of +/-10%.The MBR blower cabinet uses a PSC motor. It is approved forapplications with cooling coils of up to 0.5 inches W.C.external static pressure.The MBR/MBE/MBVC blower cabinets with proper coilmatches can be positioned for upflow, counterflow, horizontalright or horizontal left operation. All units are constructed withR-4.2 insulation. In areas of extreme humidity (greater than80% consistently), insulate the exterior of the blower withinsulation having a vapor barrier equivalent to ductworkinsulation, providing local codes permit.The CAPX/CHPX coils are equipped with a thermostaticexpansion valve that has a built-in internal check valve forrefrigerant metering. The CACF/CAPF/CHPF coils areequipped with a fixed restrictor orifice.The coils are designed for upflow, counterflow or horizontalapplication, using two-speed direct drive motors on theCACF/CAPF/CHPX models and BPM (Brushless PermanentMagnet) or ECM motors on the MBE/MBVC models.

Communicating Unitary Control (UC) PCBThe Communicating System Unitary Control PCB is a micro-processor-based control for heat pump and air conditioningcondensing units with single-phase compressors up to 5 toncapacity operating on standard residential or Delta and Wyecommercial power. The control incorporates the basic func-tionality of existing defrost controls, outdoor thermostats,contactors, compressor staging controls, short cycle con-trols, line voltage monitors, Comfort Alert Module, two speedcondenser fan relays and the Active Protection component ofenabled thermostats. The control is designed to work as partof a fully communicating HVAC system with 4 wires. Thecontrol also supports legacy 24VAC thermostat inputs forY1, Y2, O and 24VAC outputs for RVS, W1, and L for non-communicating systems. Outputs include compressor power,compressor stage select, and outdoor fan high and outdoorfan low speed. System inputs include high/low pressureswitches, as well as thermistor inputs for outdoor coiltemperature and outdoor air temperature.

Page 46: Service Manual - R410a - RS6200006R32[1]

PRODUCT DESIGN

46

The ASX & ASXC [16 & 18], ASZ & ASZC [16 & 18], DSX &DSXC [16 & 18] and DSZ & DSZC [16 & 18] series splitsystem units use a two-stage scroll compressor. The two-step modulator has an internal unloading mechanism thatopens a bypass port in the first compression pocket, effec-tively reducing the displacement of the scroll. The openingand closing of the bypass port is controlled by an internalelectrically operated solenoid.

The ZPS/ZRS two-step modulated scroll uses a single stepof unloading to go from full capacity to approximately 67%capacity. A single speed, high efficiency motor continues torun while the scroll modulates between the two capacitysteps.

FIGURE A

A scroll is an involute spiral which, when matched with amating scroll form as shown, generates a series of crescentshaped gas pockets between the two members.During compression, one scroll remains stationary (fixedscroll) while the other form (orbiting scroll) is allowed to orbit(but not rotate) around the first form.

As this motion occurs, the pockets between the two formsare slowly pushed to the center of the two scrolls whilesimultaneously being reduced in volume. When the pocketreaches the center of the scroll form, the gas, which is nowat a high pressure, is discharged out of a port located at thecenter.During compression, several pockets are being compressedsimultaneously, resulting in a very smooth process. Both thesuction process (outer portion of the scroll members) and thedischarge process (inner portion) are continuous.Some design characteristics of the Compliant Scroll com-pressor are:• Compliant Scroll compressors are more tolerant of liquid

refrigerant.NOTE: Even though the compressor section of a Scrollcompressor is more tolerant of liquid refrigerant, contin-ued floodback or flooded start conditions may wash oilfrom the bearing surfaces causing premature bearingfailure.

• "Ultratech" Series scroll compressors use "POE" orpolyolester oil which is NOT compatible with mineral oilbased lubricants like 3GS. "POE" oil must be used ifadditional oil is required.

• Compliant scroll compressors perform "quiet" shutdownsthat allow the compressor to restart immediately withoutthe need for a time delay. This compressor will restarteven if the system has not equalized.NOTE: Operating pressures and amp draws may differfrom standard reciprocating compressors. This informa-tion can be found in the unit's Technical InformationManual.

Page 47: Service Manual - R410a - RS6200006R32[1]

PRODUCT DESIGN

47

CAPACITY CONTROL - LEGACY MODELSDuring the compression process, there are several pocketswithin the scroll that are compressing gas. Modulation isachieved by venting a portion of the gas in the first suctionpocket back to the low side of the compressor therebyreducing the effective displacement of the compressor. SeeFigure A. Full capacity is achieved by blocking these vents,increasing the displacement to 100%. A solenoid in thecompressor, controlled by an external 24-volt ac signal,moves the slider ring that covers and uncovers these vents.The vent covers are arranged in such a manner that thecompressor operates somewhere around 67% capacity whenthe solenoid is not energized and 100% capacity when thesolenoid is energized. The loading and unloading of the twostep scroll is done “on the fly” without shutting off the motorbetween steps. See Figure B below. The unloaded modedefault was chosen for two reasons:

FIGURE B

1. It is expected that the majority of run hours will be in thelow capacity, unloaded mode.

2. It allows a simple two-stage thermostat to control capac-ity through the second stage in both cooling and possiblyheating if desired.

UNLOADER SOLENOIDA nominal 24-volt direct current coil activates the internalunloader solenoid. The input control circuit voltage must be18 to 28 volt ac. The coil power requirement is 20 VA. Theexternal electrical connection is made with a molded plugassembly. This plug is connected to the Comfort AlertModule which contains a full wave rectifier to supply directcurrent to the unloader coil.

CAPACITY CONTROL - COMFORTNETTM

MODELSDuring the compression process, there are several pocketswithin the scroll that are compressing gas. Modulation isachieved by venting a portion of the gas in the first suctionpocket back to the low side of the compressor therebyreducing the effective displacement of the compressor. SeeFigure A. Full capacity is achieved by blocking these vents,increasing the displacement to 100%. A solenoid in thecompressor, controlled by an external 24-volt ac signal,moves the slider ring that covers and uncovers these vents.The vent covers are arranged in such a manner that thecompressor operates somewhere around 67% capacity whenthe solenoid is not energized and 100% capacity when thesolenoid is energized. The loading and unloading of the twostep scroll is done “on the fly” without shutting off the motorbetween steps. See Figure C below. The unloaded modedefault was chosen for two reasons:

Molded Plug*

Line

LineRun Capacitor

Internal UnloaderCoil

24 VAC

*Rectifier is integrated on the UC PCB

FIGURE C

1. It is expected that the majority of run hours will be in thelow capacity, unloaded mode.

2. It allows a simple two-stage thermostat to control capac-ity through the second stage in both cooling and possiblyheating if desired.

UNLOADER SOLENOIDA nominal 24-volt direct current coil activates the internalunloader solenoid. The input control circuit voltage must be18 to 28 volt ac. The coil power requirement is 20 VA. Theexternal electrical connection is made with a molded plugassembly. This plug is connected to the CommunicatingUnitary Control PCB (UC PCB) which contains a full waverectifier to supply direct current to the unloader coil.

Page 48: Service Manual - R410a - RS6200006R32[1]

SYSTEM OPERATION

48

COOLINGThe refrigerant used in the system is R-410A. It is a clear,colorless, non-toxic and non-irritating liquid. R-410A is a50:50 blend of R-32 and R-125. The boiling point at atmo-spheric pressure is -62.9°F.A few of the important principles that make the refrigerationcycle possible are: heat always flows from a warmer to acooler body. Under lower pressure, a refrigerant will absorbheat and vaporize at a low temperature. The vapors may bedrawn off and condensed at a higher pressure and tempera-ture to be used again.The indoor evaporator coil functions to cool and dehumidifythe air conditioned spaces through the evaporative processtaking place within the coil tubes.NOTE: The pressures and temperatures shown in therefrigerant cycle illustrations on the following pages are fordemonstration purposes only. Actual temperatures and pres-sures are to be obtained from the "Expanded PerformanceChart".Liquid refrigerant at condensing pressure and temperatures,(270 psig and 122°F), leaves the outdoor condensing coilthrough the drier and is metered into the indoor coil throughthe metering device. As the cool, low pressure, saturatedrefrigerant enters the tubes of the indoor coil, a portion of theliquid immediately vaporizes. It continues to soak up heat andvaporizes as it proceeds through the coil, cooling the indoorcoil down to about 48°F.Heat is continually being transferred to the cool fins and tubesof the indoor evaporator coil by the warm system air. Thiswarming process causes the refrigerant to boil. The heatremoved from the air is carried off by the vapor.As the vapor passes through the last tubes of the coil, itbecomes superheated. That is, it absorbs more heat than isnecessary to vaporize it. This is assurance that only dry gaswill reach the compressor. Liquid reaching the compressorcan weaken or break compressor valves.The compressor increases the pressure of the gas, thusadding more heat, and discharges hot, high pressure super-heated gas into the outdoor condenser coil.In the condenser coil, the hot refrigerant gas, being warmerthan the outdoor air, first loses its superheat by heat trans-ferred from the gas through the tubes and fins of the coil. Therefrigerant now becomes saturated, part liquid, part vapor andthen continues to give up heat until it condenses to a liquidalone. Once the vapor is fully liquefied, it continues to give upheat which subcools the liquid, and it is ready to repeat thecycle.HEATINGThe heating portion of the refrigeration cycle is similar to thecooling cycle. By energizing the reversing valve solenoid coil,the flow of the refrigerant is reversed. The indoor coil nowbecomes the condenser coil, and the outdoor coil becomesthe evaporator coil.

The check valve at the indoor coil will open by the flow ofrefrigerant letting the now condensed liquid refrigerant by-pass the indoor expansion device. The check valve at theoutdoor coil will be forced closed by the refrigerant flow,thereby utilizing the outdoor expansion device.The restrictor orifice used with the CA*F, CHPF and CH**FCBcoils will be forced onto a seat when running in the coolingcycle, only allowing liquid refrigerant to pass through theorifice opening. In the heating cycle, it will be forced off theseat allowing liquid to flow around the restrictor. A check valveis not required in this circuit.COOLING CYCLEFor legacy room thermostat: When the room thermostat callsfor cool, the contacts of the room thermostat close makingterminals R to Y1 & G (if thermostat calls for low stage cool),or R to Y1, Y2 & G (if thermostat calls for high stage cool),the low voltage circuit of the transformer is completed.Current now flows through the magnetic holding coils of thecompressor contactor (CC) and fan relay (RFC). If thermostatcalls for high stage cool, the microprocessor on the UC boardwill also energize the compressor high stage solenoid to runthe compressor at full capacity.This draws in the normally open contact CC, starting thecompressor and condenser fan motors in either low or highstage depending on the thermostat’s demand. At the sametime, contacts RFC close, starting the indoor fan motor.When the thermostat is satisfied, it opens its contacts,breaking the low voltage circuit, causing the compressorcontactor and indoor fan relay to open, shutting down thesystem.If the room thermostat fan selector switch should be set onthe “on” position, then the indoor blower would run continu-ously rather than cycling with the compressor.GSZ, ASZ, SSZ, DSZ, and VSZ models energize the revers-ing valve thorough the "O" circuit in the room thermostat.Therefore, the reversing valve remains energized as long asthe thermostat subbase is in the cooling position. The onlyexception to this is during defrost.For heat pumps, during cooling cycle the reversing valve isenergized as the room thermostat closes “O” terminal to Rand the microprocessor on the UC board responds to such acondition by energizing the solenoid coil on the reversingvalve.For communicating room thermostat: When the room ther-mostat calls for either low stage cool or high stage cool,appropriate commands are sent via the data 1 and data 2 linesto the outdoor unit's UC control. The UC control energizes theon-board compressor relay and the on-board outdoor fanrelay. The compressor high stage solenoid is energized if itis a high stage call.The UC control sends a fan command to the indoor unit (airhandler or furnace). The indoor unit operates the indoorblower at the appropriate airflow level. The system operatesat the cooling level demanded by the thermostat.

Page 49: Service Manual - R410a - RS6200006R32[1]

SYSTEM OPERATION

49

When the thermostat is satisfied, appropriate commands aresent to the UC control. The compressor relay and outdoorfan relay is de-energized. The compressor high stagesolenoid is de-energized if it was energized. The UC controlsends an appropriate command to the indoor unit to de-energize the indoor blower motor.If room thermostat fan status is set to be “on”, then indoorblower would run continuously rather than cycling with thecompressor.For heat pumps, the reversing valve is energized during acooling a cycle. The call for cooling from the communicatingthermostat indicates to the control that the reversing valve isto be energized during cooling operation.

DEFROST CYCLE - LEGACY MODELSThe defrosting of the outdoor coil is jointly controlled by thedefrost control board and the defrost thermostat.

Solid State Defrost ControlDuring operation the power to the circuit board is controlledby a temperature sensor, which is clamped to a return bend(3/8" coils) or a feeder tube (5 mm coils) entering the outdoorcoil. Defrost timing periods of 30, 60, or 90 minutes may beselected by connecting the circuit board jumper to 30, 60, or90 respectively. Accumulation of time for the timing periodselected starts when the sensor closes (approximately 31°F), and when the room thermostat calls for heat. At the endof the timing period, the unit’s defrost cycle will be initiatedprovided the sensor remains closed. When the sensor opens(approximately 75° F), the defrost cycle is terminated and thetiming period is reset. If the defrost cycle is not terminateddue to the sensor temperature, a ten minute override inter-rupts the unit’s defrost period. The new upgraded defrostcontrol has a 12 minute override interrupt.

DEFROST CYCLE - COMFORTNETTM MODELSThe defrosting of the outdoor coil is jointly controlled by theUC PCB and the outdoor coil temperature (OCT) sensor.The OCT sensor is clamped to a feeder tube entering theoutdoor coil. Defrost timing periods of 30, 60, 90 or 120minutes may be selected via the dipswitch settings on the UCPCB. In a communicating system, the defrost timing periodscan also be selected in the communicating thermostat usermenu. During operation the microprocessor on the UC checkscoil temperature via the OCT sensor every 30, 60, 90, or 120minutes when there is a call for heating. If by the time themicroprocessor checks the coil temperature, and it's lowenough (approximately 31°F), and if there is a call for heatfrom the thermostat, the PCB will initiate a defrost. When themicroprocessor detects the coil temperature to be highenough (approximately 75 0F), or 10 minutes of maximum

defrost cycle time has elapsed, whichever occurs first, thedefrost cycle is terminated and the timing period is reset. Thefield service personnel can also advance a heat pump to thedefrost cycle by simultaneously pressing the “TEST” buttonand the “RECALL” button on the UC board.

HEATING CYCLEThe reversing valve on the GSZ, SSZ, ASZ and DSZ modelsis energized in the cooling cycle through the "O" terminal onthe room thermostat.These models have a 24 volt reversing valve coil. When thethermostat selector switch is set in the cooling position, the"O" terminal on the thermostat is energized all the time.Care must be taken when selecting a room thermostat. Referto the installation instructions shipped with the product forapproved thermostats.

HEATING CYCLEFor legacy room thermostat: When the room thermostatcalls for heat, the contacts of the room thermostat closemaking terminals R to Y & G, the low voltage circuit of thetransformer is completed. Current now flows through themagnetic holding coils of the compressor contactor (CC) andfan relay (RFC).This draws in the normally open contact CC, starting thecompressor condenser fan motors. At the same time,contacts RFC close, starting the indoor fan motor.When the thermostat is satisfied, it opens its contacts,breaking the low voltage circuit, causing the compressorcontactor and indoor fan relay to open, shutting down thesystem.If the room thermostat fan selector switch should be set tothe “on” position, then the indoor blower would run continu-ously rather than cycling with the compressor.For communicating room thermostat: When the room ther-mostat calls for either low stage heat or high stage heat,appropriate commands are sent via the data 1 and data 2lines to the outdoor unit's UC control. The UC controlenergizes the on-board compressor relay and the on-boardoutdoor fan relay. The compressor high stage solenoid isenergized if it is a high stage call. The UC control sends afan command to the indoor unit (air handler or furnace). Theindoor unit operates the indoor blower at the appropriateairflow level. The system operates at the cooling leveldemanded by the thermostat.

Page 50: Service Manual - R410a - RS6200006R32[1]

SYSTEM OPERATION

50

COOLING CYCLE

HEATING CYCLE

IndoorCoil

Accumulator

Bi-FlowFilter Dryer

OutdoorCoil

ThermostaticExpansion

Valve

Check Valve

Reversing Valve(De-Energized)

IndoorCoil

Accumulator

Bi-FlowFilter Dryer

OutdoorCoil

ThermostaticExpansion

Valve

Check Valve

Reversing Valve(Energized)

Page 51: Service Manual - R410a - RS6200006R32[1]

SYSTEM OPERATION

51

RESTRICTOR ORIFICE ASSEMBLYIN COOLING OPERATION

RESTRICTOR ORIFICE ASSEMBLYIN HEATING OPERATION

In the cooling mode, the orifice is pushed into itsseat, forcing refrigerant to flow through the metered

hole in the center of the orifice.

In the heating mode, the orifice moves back off itsseat, allowing refrigerant to flow unmetered around

the outside of the orifice.

EXPANSION VALVE/CHECK VALVE ASSEMBLYIN COOLING OPERATION

EXPANSION VALVE/CHECK VALVE ASSEMBLYIN HEATING OPERATION

Most expansion valves used in current Amana® Brand Heat Pump productsuse an internally checked expansion valve.

This type of expansion valve does not require an external check valve as shown above.However, the principle of operation is the same.

Page 52: Service Manual - R410a - RS6200006R32[1]

SYSTEM OPERATION

52

AFE18-60A CONTROL BOARDDESCRIPTIONThe AFE18 control is designed for use in heat pump applica-tions where the indoor coil is located above/downstream of agas or fossil fuel furnace. It will operate with single and twostage heat pumps and single and two stage furnaces. TheAFE18 control will turn the heat pump unit off when thefurnace is turned on. An anti-short cycle feature is alsoincorporated which initiates a 3 minute timed off delay whenthe compressor goes off. On initial power up or loss andrestoration of power, this 3 minute timed off delay will beinitiated. The compressor won’t be allowed to restart until the3 minute off delay has expired. Also included is a 5 secondde-bounce feature on the “Y, E, W1 and O” thermostat inputs.These thermostat inputs must be present for 5 secondsbefore the AFE18 control will respond to it.An optional outdoor thermostat, OT18-60A, can be used withthe AFE18 to switch from heat pump operation to furnace

operation below a specific ambient temperature setting, i.e.break even temperature during heating. When used in thismanner, the “Y” heat demand is switched to the “W1” inputto the furnace by the outdoor thermostat and the furnace isused to satisfy the first stage “Y” heat demand. On somecontrols, if the outdoor thermostat fails closed in this positionduring the heating season, it will turn on the furnace duringthe cooling season on a “Y” cooling demand. In thissituation, the furnace produces heat and increases theindoor temperature thereby never satisfying the coolingdemand. The furnace will continue to operate and can onlybe stopped by switching the thermostat to the off position orremoving power to the unit and then replacing the outdoorthermostat. When the AFE18 receives a “Y” and “O”input from the indoor thermostat, it recognizes this as acooling demand in the cooling mode. If the outdoor thermo-stat is stuck in the closed position switching the “Y” demandto the “W1” furnace input during the cooling mode asdescribed above, the AFE18 won’t allow the furnace tooperate. The outdoor thermostat will have to be replaced torestore the unit to normal operation.

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

When the thermostat is satisfied, appropriate commands aresent to the UC control. The compressor relay and outdoorfan relay is de-energized. The compressor high stagesolenoid is de-energized if it was energized. The UC controlsends an appropriate command to the indoor unit to de-energize the indoor blower motor.

Page 53: Service Manual - R410a - RS6200006R32[1]

53

TROUBLESHOOTING CHART

Com plaintSystem

Operating Pre ss ure s

POSSIBLE CAUSE

DOTS IN ANALYSISGUIDE INDICATE

"POSSIBLE CAUSE" SYM

PTO

MS

yste

m w

ill n

ot s

tart

Com

pres

sor w

ill n

ot s

tart

- fan

runs

Com

p. a

nd C

ond.

Fan

will

not

sta

rt

Evap

orat

or fa

n w

ill n

ot s

tart

Con

dens

er fa

n w

ill n

ot s

tart

Com

pres

sor r

uns

- goe

s of

f on

over

load

Com

pres

sor c

ycle

s on

ove

rload

Syst

em ru

ns c

ontin

uous

ly -

little

coo

ling/

htg

Too

cool

and

then

too

war

m

Not

coo

l eno

ugh

on w

arm

day

s

Cer

tain

are

as to

o co

ol, o

ther

s to

o w

arm

Com

pres

sor i

s no

isy

Syst

em ru

ns -

blow

s co

ld a

ir in

hea

ting

Uni

t will

not

term

inat

e de

frost

Uni

t will

not

def

rost

Low

suc

tion

pres

sure

Low

hea

d pr

essu

re

Hig

h su

ctio

n pr

essu

re

Hig

h he

ad p

ress

ure

Test MethodRemedy

See

Serv

ice

Proc

edur

e R

ef.

Pow er Failure • Test V oltage S-1Blow n Fuse • • • Inspect Fuse Size & Type S-1Unbalanced Pow er, 3PH • • • Test V oltage S-1Loose Connection • • • Inspect Connection - Tighten S-2, S-3Shorted or Broken Wires • • • • • • Test Circuits With Ohmmeter S-2, S-3Open Fan Overload • • Test Continuity of Overload S-17AFaulty Thermostat • • • • Test Continuity of Thermostat & Wiring S-3Faulty Transformer • • Check Control Circuit w ith V oltmeter S-4Shorted or Open Capacitor • • • • • Test Capacitor S-15Internal Compressor Overload Open • ♦ Test Continuity of Overload S-17AShorted or Grounded Compressor • • Test Motor Windings S-17BCompressor Stuck • • • ♦ Use Test Cord S-17DFaulty Compressor Contactor • • • Test Continuity of Coil & Contacts S-7, S-8Faulty Fan Relay • Test Continuity of Coil A nd Contacts S-7Open Control Circuit • Test Control Circuit w ith Voltmeter S-4Low V oltage • • • Test V oltage S-1Faulty Evap. Fan Motor • • ♦ Repair or Replace S-16Shorted or Grounded Fan Motor • • Test Motor Windings S-16Improper Cooling A ntic ipator • • Check Resistance of A ntic ipator S-3BShortage of Refrigerant • • ♦ • • Test For Leaks, Add Ref rigerant S-101,103Restric ted Liquid Line • • • • • Remove Restric tion, Replace Restricted Part S-112Open Element or Limit on Elec. Heater ♦ ♦ Test Heater Element and Controls S-26,S-27Dirty A ir Filter • • • • ♦ Inspect Filter-Clean or ReplaceDirty Indoor Coil • • • • ♦ Inspect Coil - CleanNot enough air across Indoor Coil • • • • ♦ Check Blow er Speed, Duct Static Press, Filter S-200Too much air across Indoor Coil ♦ • Reduce Blow er Speed S-200Overcharge of Ref rigerant • • • ♦ • • Recover Part of Charge S-113Dirty Outdoor Coil • • • ♦ • Inspect Coil - CleanNoncondensibles • • ♦ • Recover Charge, Evacuate, Recharge S-114Recirculation of Condensing A ir • • • Remove Obstruction to A ir FlowInf iltration of Outdoor A ir • • • Check Window s, Doors, V ent Fans, Etc.Improperly Located Thermostat • • Relocate ThermostatA ir Flow Unbalanced • • Readjust A ir Volume DampersSystem Unders ized • • Ref igure Cooling LoadBroken Internal Parts • ♦ Replace Compressor S-115Broken Valves • • • • Test Compressor Ef f iciency S-104Inef f ic ient Compressor • ♦ • • Test Compressor Ef f iciency S-104Wrong Type Expansion V alve • • • • • • ♦ Replace V alve S-110Expansion Device Restric ted • • • • • • • Remove Restric tion or Replace Expansion Device S-110Overs ized Expansion Valve • • Replace V alveUnders ized Expansion V alve • • • • • Replace V alveExpansion Valve Bulb Loose • • Tighten Bulb Bracket S-105Inoperative Expansion V alve • • • Check Valve Operation S-110Loose Hold-dow n Bolts • Tighten BoltsFaulty Revers ing Valve • ♦ ♦ ♦ ♦ ♦ ♦ Replace V alve or Solenoid S-21, 122Faulty Def rost Control • ♦ ♦ ♦ ♦ ♦ ♦ Test Control S-24Faulty Def rost Thermostat ♦ ♦ ♦ ♦ ♦ ♦ ♦ Test Def rost Thermostat S-25Flow rator Not Seating Properly • • • Check Flow rator & Seat or Replace Flow rator S-111

• Cooling or Heating Cycle (He at Pum p) ♦

COOLING/HP ANALYSIS CHART

No CoolingUns atis factory

Cooling/He ating

He ating Cycle Only (He at Pum p)

Page 54: Service Manual - R410a - RS6200006R32[1]

SERVICING

54

HIGH VOLTAGE!Disconnect ALL power before servicing or installing. Multiple power sources may be present. Failure todo so may cause property damage, personal injury or death.

S-1 CHECKING VOLTAGE ...........................................................55S-2 CHECKING WIRING ............................................................... 55S-3 CHECKING THERMOSTAT, WIRING, AND ANTICIPATOR ...... 55S-3A THERMOSTAT AND WIRING ..................................................55S-3B COOLING ANTICIPATOR ....................................................... 56S-3C HEATING ANTICIPATOR......................................................... 56S-3E CTK0*** COMFORTNETTM THERMOSTAT ............................ 57S-4 CHECKING TRANSFORMER AND CONTROL CIRCUIT ......... 62S-5 CHECKING CYCLE PROTECTOR .......................................... 62S-6 CHECKING TIME DELAY RELAY ........................................... 62S-7 CHECKING CONTACTOR AND/OR RELAYS ........................ 63S-8 CHECKING CONTACTOR CONTACTS .................................. 63S-8A CHECKING UNITARY (UC) CONTROL COMPRESSOR

CONTACTOR/RELAY CONTACTS ........................................ 63S-9 CHECKING FAN RELAY CONTACTS .................................... 64S-10 COPELAND COMFORT ALERT™.......................................... 67S-11 CHECKING LOSS OF CHARGE PROTECTOR ...................... 74S-12 CHECKING HIGH PRESSURE CONTROL .............................. 74S-13 CHECKING LOW PRESSURE CONTROL .............................. 74S-15 CHECKING CAPACITOR ........................................................74S-15A RESISTANCE CHECK ............................................................ 75S-15B CAPACITANCE CHECK.......................................................... 75S-16A CHECKING FAN AND BLOWER MOTOR WINDINGS (PSC

MOTORS) .............................................................................. 76S-16B CHECKING FAN AND BLOWER MOTOR (ECM MOTORS) ... 76S-16C CHECKING ECM MOTOR WINDINGS .................................... 79S-16D ECM CFM ADJUSTMENTS MBE / AEPF ................................. 79S-16F CHECKING HIGH EFFICIENCY MOTORS ............................... 81S-16E BLOWER PERFORMANCE DATA .......................................... 81S-16G CHECKING EMERSON ULTRATECHTM ECM MOTORS ........82S-16H ECM CFM ADJUSTMENTS AVPTC/MBVC .............................84S-17 CHECKING COMPRESSOR ................................................... 87S-17A RESISTANCE TEST ............................................................... 87S-17B GROUND TEST ...................................................................... 87S-17C UNLOADER TEST PROCEDURE ............................................88S-17D OPERATION TEST .................................................................88S-18 TESTING CRANKCASE HEATER (OPTIONAL ITEM) ............ 89S-21 CHECKING REVERSING VALVE AND SOLENOID ................ 89S-24 TESTING DEFROST CONTROL ............................................. 89S-25 TESTING DEFROST THERMOSTAT ......................................90

S-26 TESTING TEMPERATURE SENSORS (COMFORTNET READYMODELS ONLY) ....................................................................90

S-40 MBR/AR*F ELECTRONIC BLOWER ......................................90TIME DELAY RELAY ............................................................. 90

S-40A AVPTC/MBVC ELECTRONIC BLOWER/HEATER CONTROL 91S-50 CHECKING HEATER LIMIT CONTROL(S) .......................... 105S-52 CHECKING HEATER ELEMENTS ........................................ 106S-60 ELECTRIC HEATER (OPTIONAL ITEM) .............................. 106S-61A CHECKING HEATER LIMIT CONTROL(S) ........................... 107S-61B CHECKING HEATER FUSE LINK ......................................... 107

(OPTIONAL ELECTRIC HEATERS) ..................................... 107S-62 CHECKING HEATER ELEMENTS ........................................ 107S-100 REFRIGERATION REPAIR PRACTICE ................................. 107S-101 LEAK TESTING (NITROGEN OR NITROGEN-TRACED) .... 108S-102 EVACUATION ..................................................................... 108S-103 CHARGING ......................................................................... 109S-104 CHECKING COMPRESSOR EFFICIENCY ............................ 109S-105A PISTON CHART FOR ........................................................... 110

ASX13, GSX13, VSX13, SSX14, ASX14,GSX14, ASZ13, GSZ13, GSZ14, VSZ13, SSZ14 UNITS . 110

S-105B THERMOSTATIC EXPANSION VALVE ................................. 114S-106 OVERFEEDING .................................................................... 114S-107 UNDERFEEDING .................................................................. 114S-108 SUPERHEAT ........................................................................ 114S-109 CHECKING SUBCOOLING ................................................... 117S-109A TWO SPEED APPLICATION ................................................. 117S-110 CHECKING EXPANSION VALVE OPERATION .................... 118S-111 FIXED ORIFICE RESTRICTOR DEVICES .............................. 118S-112 CHECKING RESTRICTED LIQUID LINE ................................ 118S-113 OVERCHARGE OF REFRIGERANT .................................... 118S-114 NON-CONDENSABLES ....................................................... 119S-115 COMPRESSOR BURNOUT .................................................. 119S-120 REFRIGERANT PIPING ......................................................... 119S-202 DUCT STATIC PRESSURES AND/OR STATIC

PRESSURE DROP ACROSS COILS ................................... 122S-203 AIR HANDLER EXTERNAL STATIC .................................... 123S-204 COIL STATIC PRESSURE DROP......................................... 123

TABLE OF CONTENTS

Page 55: Service Manual - R410a - RS6200006R32[1]

SERVICING

55

S-1 CHECKING VOLTAGE

1. Remove outer case, control panel cover, etc., from unitbeing tested.

With power ON:

WARNINGLine Voltage now present.

2. Using a voltmeter, measure the voltage across terminalsL1 and L2 of the contactor for the condensing unit or at thefield connections for the air handler or heaters.ComfortNetTM Ready Condensing Units: Measure thevoltage across the L1 and L2 lugs on the unitary (UC)control.

3. No reading - indicates open wiring, open fuse(s) no poweror etc., from unit to fused disconnect service. Repair asneeded.

4. With ample voltage at line voltage connectors, energizethe unit.

5. Measure the voltage with the unit starting and operating,and determine the unit Locked Rotor Voltage. NOTE: Ifchecking heaters, be sure all heating elements areenergized.Locked Rotor Voltage is the actual voltage available atthe compressor during starting, locked rotor, or a stalledcondition. Measured voltage should be above minimumlisted in chart below.To measure Locked Rotor Voltage attach a voltmeter tothe run "R" and common "C" terminals of the compressor,or to the T1 and T2 terminals of the contactor. Start the unitand allow the compressor to run for several seconds, thenshut down the unit. Immediately attempt to restart theunit while measuring the Locked Rotor Voltage.ComfortNet Ready Condensing Units: To measure theLocked Rotor Voltage, attach a voltmeter to the run "R"and common "C" terminals of the compressor or acrossthe "R" and "C" lugs on the unitary (UC) control. Start theunit and allow the compressor to run for several seconds,then shut down the unit. Immediately attempt to restartthe unit while measuring the Locked Rotor Voltage.

6. Locked rotor voltage should read within the voltage tabu-lation as shown. If the voltage falls below the minimumvoltage, check the line wire size. Long runs of undersizedwire can cause low voltage. If wire size is adequate, notifythe local power company in regard to either low or highvoltage.

VOLTAGE MIN. MAX.460 437 506

208/230 198 253

UNIT SUPPLY VOLTAGE

NOTE: When operating electric heaters on voltages otherthan 240 volts, refer to the System Operation section onelectric heaters to calculate temperature rise and air flow.Low voltage may cause insufficient heating.

S-2 CHECKING WIRING

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Check wiring visually for signs of overheating, damagedinsulation and loose connections.

2. Use an ohmmeter to check continuity of any suspectedopen wires.

3. If any wires must be replaced, replace with comparablegauge and insulation thickness.

S-3 CHECKING THERMOSTAT, WIRING, ANDANTICIPATOR

THERMOSTAT WIRE SIZING CHART

LENGTH OF RUNMIN. COPPER WIRE

GAUGE (AWG)25 feet 1850 feet 1675 feet 14100 feet 14125 feet 12150 feet 12

ComfortNet Ready Models1. Legacy Thermostat Wiring: The maximum wire length for

18 AWG thermostat wire is 100 feet.2. Communicating Thermostat Wiring: The maximum wire

length for 18 AWG thermostat wire is 100 feet.

S-3A THERMOSTAT AND WIRING

WARNINGLine Voltage now present.

With power ON, thermostat calling for cooling1. Use a voltmeter to check for 24 volts at thermostat wires

C and Y in the condensing unit control panel.2. No voltage indicates trouble in the thermostat, wiring or

external transformer source.3. Check the continuity of the thermostat and wiring. Repair

or replace as necessary.

Page 56: Service Manual - R410a - RS6200006R32[1]

SERVICING

56

Indoor Blower MotorWith power ON:

WARNINGLine Voltage now present.

1. Set fan selector switch at thermostat to "ON" position.2. With voltmeter, check for 24 volts at wires C and G.3. No voltage indicates the trouble is in the thermostat or

wiring.4. Check the continuity of the thermostat and wiring. Repair

or replace as necessary.

Resistance Heaters1. Set room thermostat to a higher setting than room

temperature so both stages call for heat.2. With voltmeter, check for 24 volts at each heater relay.

Note: BBA/BBC heater relays are DC voltage.3. No voltage indicates the trouble is in the thermostat or

wiring.4. Check the continuity of the thermostat and wiring. Repair

or replace as necessary.NOTE: Consideration must be given to how the heaters arewired (O.D.T. and etc.). Also safety devices must be checkedfor continuity.

S-3B COOLING ANTICIPATORThe cooling anticipator is a small heater (resistor) in thethermostat. During the "off" cycle, it heats the bimetalelement helping the thermostat call for the next coolingcycle. This prevents the room temperature from rising toohigh before the system is restarted. A properly sizedanticipator should maintain room temperature within 1 1/2 to2 degree range.The anticipator is supplied in the thermostat and is not to bereplaced. If the anticipator should fail for any reason, thethermostat must be changed.

S-3C HEATING ANTICIPATORThe heating anticipator is a wire wound adjustable heaterwhich is energized during the "ON" cycle to help preventoverheating of the conditioned space.The anticipator is a part of the thermostat and if it should failfor any reason, the thermostat must be replaced. See thefollowing tables for recommended heater anticipator settingin accordance to the number of electric heaters installed.

Page 57: Service Manual - R410a - RS6200006R32[1]

SERVICING

57

S-3E CTK0*** COMFORTNETTM THERMOSTAT

OVERVIEWThe ComfortNet system (or CT system) is a system thatincludes a ComfortNet compatible modular blower and airconditioner or heat pump with a CTK0* thermostat. Any othersystem configurations are considered invalid ComfortNetsystems and must be connected as a traditional (or legacy)system. The table below compares the valid CT systems.

CT compatible Air Handler or Modular Blower

CT compatibleAir Conditioner

Full CT systembenefits & features

CT compatible Air Handler or Modular Blower

CT compatibleHeat Pump

Full CT systembenefits & features

A ComfortNet heating/air conditioning system differs from alegacy/traditional system in the manner in which the indoorunit, outdoor unit and thermostat interact with one another. Ina traditional system, the thermostat sends commands to theindoor and outdoor units via analog 24 VAC signals. It is aone-way communication path in that the indoor and outdoorunits typically do not return information to the thermostat.On the other hand, the indoor unit, outdoor unit, and thermo-stat comprising a ComfortNet system “communicate” digi-tally with one another. It is now a two-way communicationspath. The thermostat still sends commands to the indoor andoutdoor units. However, the thermostat may also request andreceive information from both the indoor and outdoor units.This information may be displayed on the CT thermostat. Theindoor and outdoor units also interact with one another. Theoutdoor unit may send commands to or request informationfrom the indoor unit. This two-way digital communicationsbetween the thermostat and subsystems (indoor/outdoorunit) and between subsystems is the key to unlocking thebenefits and features of the ComfortNet system.Two-way digital communications is accomplished using onlytwo wires. The thermostat and subsystem controls arepowered with 24 VAC Thus, a maximum of 4 wires betweenthe equipment and thermostat is all that is required to operatethe system.

CTK0* WIRING

NOTE: A removable plug connector is provided with thecontrol to make thermostat wire connections. This plug maybe removed, wire connections made to the plug, and replaced.It is strongly recommended that multiple wires into a singleterminal be twisted together prior to inserting into the plugconnector. Failure to do so may result in intermittentoperation.Typical 18 AWG thermostat wire may be used to wire thesystem components. However, communications reliabilitymay be improved by using a high quality, shielded, twistedpair cable for the data transmission lines. In either case, 100feet is the maximum length of wire between indoor unit andoutdoor unit, or between indoor unit and thermostat.

FOUR-WIRE INDOOR AND OUTDOOR WIRING

Typical wiring will consist of four wires between the indoor unitand outdoor unit and between the indoor unit and thermostat.The required wires are: (a) data lines, 1 and 2; (b) thermostat“R” (24 VAC hot) and “C” (24 VAC common).

12 R

C

1 2 R C

1 2 R C

CTK0*Thermostat

CT™ CompatibleModular BlowerIntegrated Control Module

CT™ Compatible AC/HPIntegrated Control Module

System Wiring Using Four-Wires

TWO-WIRE OUTDOOR, FOUR-WIRE INDOOR WIRING

Two wires only may be utilized between the indoor andoutdoor units. For this wiring scheme, only the data lines, 1and 2, are required between the indoor and outdoor units. A40VA, 208/230 VAC to 24 VAC transformer must be installedin the outdoor unit to provide 24 VAC power to the outdoorunit’s electronic control. The transformer is included with theCTK0* kit. See kit instructions for mounting and wiringinstructions. Four wires are required between the indoor unitand thermostat.

12 R

C

1 2 R C

1 2 R C

CTK0*Thermostat

CT CompatibleModular BlowerIntegrated Control Module

CT CompatibleAC/HP IntegratedControl Module

40VA Transformer (included in CTK0*** kit)

208/230 VAC 24 VAC

System Wiring using Two-Wires between Furnace and AC/HP and Four-Wires between Furnace and Thermostat

Page 58: Service Manual - R410a - RS6200006R32[1]

SERVICING

58

COMFORTNET™ SYSTEM ADVANCED FEATURESThe ComfortNet system permits access to additional sys-tem information, advanced setup features, and advanceddiagnostic/troubleshooting features. These advanced fea-tures are organized into a menu structure. The menus areaccessed and navigated as described as follows.

ACCESSING AND NAVIGATING THE ADVANCED FEATURESMENUS

The advanced system features are accessed using theComfortNet™ thermostat. These advanced features areaccessed as follows:

• On the CT thermostat Home Screen Display, touchthe Menu key to display additional key choices.

• Touch and hold the Installer Config key for approxi-mately 3 seconds to enter the Thermostat OptionsConfiguration menu.

• Touch and hold the Installer Config key again forapproximately 3 seconds to enter the Advanced In-staller Configuration menu.

Clean Display InstallerConfig

Set Time Set Schedule

R unSchedule

Upon entering the advanced menus, the Advanced FaultMenu is displayed. The display will change to the FaultScreen and indicate any faults that may be present in theindoor or outdoor equipment. If a fault is present, the Fault

Screen will show the equipment and an error code with adescription of the fault. Touch _ or + keys to view the faultstatus of any remaining equipment. The text “NO FAULTS”will be scrolled if no errors are present.

MenuRun

Schedule

Call for Service

Advanced

MenuRun

Schedule

Call for Service

Advanced

Touch the + or _ to step through the list of installedequipment, including the thermostat. Touch the InstallerConfig key to enter the submenus for the equipment dis-played. The text “WORKING” will be displayed in thescrolling display area while the data is being retrieved. Thefirst sub-menu is then displayed. See tables below for listingof modular blower submenus.Touch the + or _ to step through the list of submenus andview settings. If a setting can be adjusted, _ and + keyswill appear. Use the _ or + keys to adjust the setting to thedesired value. Touch the + or _ to step to the next item.“WORKING” will appear as the settings are being updated.“DONE” will appear to indicate the change was accepted. Ifthe change is not accepted, the display will show “FAIL”then revert to the Fault Screen.Some parameters being displayed switch between the itemname and the item value. Touch the Hold key to momentarilystop the display from switching.To exit an equipment submenu and revert back to theequipment menus, touch the Menu key. Touch Menu againto revert back to the Thermostat Options Menu. Touch theRun Schedule key to step out of all menus and back to theCT thermostat Home Screen Display.

Page 59: Service Manual - R410a - RS6200006R32[1]

SERVICING

59

Submenu Item Indication (for Display Only; not User Modifiable)Electric Heat Size (HTR KW) Displays the size in kW of the selected electric heaters.Motor HP (1/2, 3/4, or 1 MTR HP) Displays the indoor blower motor horsepower.

Heat ON Delay (HT ON) Displays the electric heat indoor blower ON delay.

Heat OFF Delay (HT OFF) Displays the electric heat indoor blower OFF delay.

CONFIGURATION

Submenu Item Indication/User Modifiable Options Comments

Fault 1 (FAULT #1) Most recent fault For display onlyFault 2 (FAULT #2) Next most recent fault For display onlyFault 3 (FAULT #3) Next most recent fault For display onlyFault 4 (FAULT #4) Next most recent fault For display onlyFault 5 (FAULT #5) Next most recent fault For display onlyFault 6 (FAULT #6) Least recent fault For display onlyClear Fault History (CLEAR) NO or YES Selecting “YES” clears the fault

historyNOTE: Consecutively repeated faults are shown a maximum of 3 times

DIAGNOSTICS

Submenu Item Indication (for Display Only; not User Modifiable)Model Number (MOD NUM) Displays the model numberSerial Number (SER NUM) Displays the serial number (Optional)Software (SOFTWARE) Displays the application software revision

IDENTIFICATION

Submenu Item User Modifiable Options CommentsHeat Airflow Trim (HT TRM)

-10% to +10% in 2% increments, default is 0%

Trims the electric heating airflow by the selected amount.

SET-UP

Submenu Item Indication (for Display Only; not User Modifiable)Mode (MODE) Displays the current operating modeCFM (CFM) Displays the airflow for the current operating mode

STATUS

AVPTC AND MBVC ADVANCED USER MENUS

Page 60: Service Manual - R410a - RS6200006R32[1]

SERVICING

60

Submenu Item User Modifiable Options CommentsOutdoor Air Temperature

(AIR TMP)Displays the outdoor air temperature

Sensor may or may not be available on an air conditioner. Check air conditioner instructions for details.

Outdoor Coil Temperature (COIL TMP)

Displays the outdoor coil temperature

Required for heat pump operation.

SENSORS

Submenu Item Indication (for Display Only; not User Modifiable)Number of AC Stages (CL STG) Displays the number of air conditioning stages; applies to AC and Number of HP Stages (HT STG) Displays the number of heat pump stages; applies to HP only.

AC Tonnage (TONS) Displays the air conditioning tonnage; applies to AC and HP.

CONFIGURATION

Submenu Item Indication/User Modifiable Options Comments

Fault 1 (FAULT #1) Most recent AC/HP fault For display onlyFault 2 (FAULT #2) Next most recent AC/HP fault For display onlyFault 3 (FAULT #3) Next most recent AC/HP fault For display onlyFault 4 (FAULT #4) Next most recent AC/HP fault For display onlyFault 5 (FAULT #5) Next most recent AC/HP fault For display onlyFault 6 (FAULT #6) Least recent AC/HP fault For display only

Clear Fault History (CLEAR) NO or YES Selecting “YES” clears the fault history

NOTE: Consecutively repeated faults are shown a maximum of 3 times

DIAGNOSTICS

Submenu Item Indication (for Display Only; not User Modifiable)Model Number (MOD NUM) Displays the air conditioner or heat pump model numberSerial Number (SER NUM) Displays the air conditioner or heat pump serial number (Optional)Software (SOFTWARE) Displays the application software revision

IDENTIFICATION

ASXC/ASZC AND DSXC/DSZC ADVANCED USER MENUS

Page 61: Service Manual - R410a - RS6200006R32[1]

SERVICING

61

Submenu Item Indication (for Display Only; not User Modifiable)Mode (MODE) Displays the current air conditioner operating modeCFM (CFM) Displays the airflow for the current operating mode

STATUS

Submenu Item User Modifiable Options CommentsHeat Airflow Trim

(HT TRM)-10% to +10% in 2% increments, default is 0%

Selects the airflow trim amount; applies to heat pump only.

Heat ON Delay(HT ON)

5, 10, or 15 seconds, default is 5 seconds

Selects the indoor blower heat ON delay; applies to heat pump only.

Heat OFF Delay(HT OFF)

30, 50, 70, or 90 seconds, default is 30 seconds

Selects the indoor blower heat OFF delay; applies to heat pump only.

Defrost Interval(DEFROST)

30, 60, 90, or 120 minutes, default is 30 minutes.

Selects the time interval between defrosts; applies to heat pump only.

Compressor Delay(CMP DLY)

0, 5, 15, or 30 seconds, default is 5 seconds

Selects the compressor off time after a reversing valve shift; applies to heat pump only.

HEAT SET-UP

Submenu Item User Modifiable Options CommentsCool Airflow Trim

(CL TRM)-10% to +10% in 2% increments, default is 0%

Selects the airflow trim amount; applies to air conditioner only.

Cool Airflow Profile(CL PRFL)

A, B, C, or D, default is A Selects the airflow profile; applies to air conditioner only.

Cool ON Delay(CL ON)

5, 10, 20, or 30 seconds, default is 5 seconds

Selects the indoor blower ON delay; applies to air conditioner only.

Cool OFF Delay(CL OFF)

30, 60, 90, or 120 seconds, default is 30 seconds

Selects the indoor blower OFF delay; applies to air conditioner only.

Dehumidification Select (DEHUM)

ON or OFF (default is OFF) Selecting "OFF" disables dehumidification; selecting "ON" enables dehumidification; applies to air conditioner only.

COOL SET-UP

ASXC/ASZC AND DSXC/DSZC ADVANCED USER MENUS, CONT'D

Page 62: Service Manual - R410a - RS6200006R32[1]

SERVICING

62

S-4 CHECKING TRANSFORMER AND CON-TROL CIRCUIT

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

A step-down transformer (208/240 volt primary to 24 volt sec-ondary) is provided with each indoor unit. This allows amplecapacity for use with resistance heaters. The outdoor sec-tions do not contain a transformer (see note below).NOTE: ComfortNetTM ready condensing units may have anoptional 240VAC to 24VAC transformer installed. This trans-former provides 24VAC power to the unitary (UC) control insome communicating system installation scenarios.

WARNINGDisconnect ALL power before servicing.

1. Remove control panel cover, or etc., to gain access totransformer.

With power ON:

WARNINGLine Voltage now present.

2. Using a voltmeter, check voltage across secondary volt-age side of transformer (R to C).

3. No voltage indicates faulty transformer, bad wiring, or badsplices.

4. Check transformer primary voltage at incoming line volt-age connections and/or splices.

5 If line voltage available at primary voltage side of trans-former and wiring and splices good, transformer is inop-erative. Replace.

S-5 CHECKING CYCLE PROTECTORSome models feature a solid state, delay-on make after breaktime delay relay installed in the low voltage circuit. Thiscontrol is used to prevent short cycling of the compressorunder certain operating conditions.The component is normally closed (R1 to Y1). A powerinterruption will break circuit (R1 to Y1) for approximately threeminutes before resetting.

1. Remove wire from Y1 terminal.2. Wait for approximately four (4) minutes if machine was

running.

With power ON:

WARNINGLine Voltage now present.

1. Apply 24 VAC to terminals R1 and R2.2. Should read 24 VAC at terminals Y1 and Y2.3. Remove 24 VAC at terminals R1 and R2.4. Should read 0 VAC at Y1 and Y2.5. Reapply 24 VAC to R1 and R2 - within approximately

three (3) to four (4) minutes should read 24 VAC at Y1 andY2.

If not as above - replace relay.

S-6 CHECKING TIME DELAY RELAYTime delay relays are used in some of the blower cabinets toimprove efficiency by delaying the blower off time. Timedelays are also used in electric heaters to sequence inmultiple electric heaters.

WARNINGDisconnect ALL power before servicing.

1. Tag and disconnect all wires from male spade connec-tions of relay.

2. Using an ohmmeter, measure the resistance acrossterminals H1 and H2. Should read approximately 150ohms.

3. Using an ohmmeter, check for continuity across termi-nals 3 and 1, and 4 and 5.

4. Apply 24 volts to terminals H1 and H2. Check forcontinuity across other terminals - should test continu-ous. If not as above - replace.

NOTE: The time delay for the contacts to make will beapproximately 20 to 50 seconds and to open after the coil isde-energized is approximately 40 to 90 seconds.

OHMMETER

TESTING COIL CIRCUIT

Page 63: Service Manual - R410a - RS6200006R32[1]

SERVICING

63

S-7 CHECKING CONTACTOR AND/OR RELAYS

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

The compressor contactor and other relay holding coils arewired into the low or line voltage circuits. When the controlcircuit is energized, the coil pulls in the normally opencontacts or opens the normally closed contacts. When thecoil is de-energized, springs return the contacts to theirnormal position.NOTE: Most single phase contactors break only one side ofthe line (L1), leaving 115 volts to ground present at mostinternal components.NOTE: The compressor contactor/relay in ComfortNetTM readyequipment is fully integrated into the unitary (UC) control.The compressor contactor/relay coil on the UC control is non-serviceable.1. Remove the leads from the holding coil.2. Using an ohmmeter, test across the coil terminals.

If the coil does not test continuous, replace the relay orcontactor.

S-8 CHECKING CONTACTOR CONTACTS

WARNINGDisconnect ALL power before servicing.

SINGLE PHASE:1. Disconnect the wire leads from the terminal (T) side of the

contactor.2. With power ON, energize the contactor.

WARNINGLine Voltage now present.

3. Using a voltmeter, test across terminals.A. L2 - T1 - No voltage indicates CC1 contacts open.

If a no voltage reading is obtained - replace the contactor.

VOLT/OHMMETER

T1T2

L1L2

CC

Ohmmeter for testing holding coilVoltmeter for testing contacts

TESTING COMPRESSOR CONTACTOR(Single Phase)

THREE PHASEUsing a voltmeter, test across terminals:

A. L1-L2, L1-L3, and L2-L3 - If voltage is present,proceed to B. If voltage is not present, check breakeror fuses on main power supply..

B. T1-T2, T1-T3, and T2-T3 - If voltage readings are notthe same as in "A", replace contactor.

VOLT/OHMMETER

CC

Ohmmeter for testing holding coilVoltmeter for testing contacts

T1

L1

T3

L3

T2

L2

TESTING COMPRESSOR CONTACTOR(Three-phase)

S-8A CHECKING UNITARY (UC) CONTROLCOMPRESSOR CONTACTOR/RELAYCONTACTS

WARNINGDisconnect ALL power before servicing.

1. Connect voltmeter to lugs (L2) and (C).2. With power ON, provide a call for cool or heat pump to

energize the on-board compressor contactor/relay.

WARNINGLine Voltage now present.

3. Measure voltage across on-board compressor contactor/relay contacts.

Page 64: Service Manual - R410a - RS6200006R32[1]

SERVICING

64

A. No voltage indicates the contacts are closed and thecontactor/relay is functioning properly.B. A reading of approximately half of the supply voltage(example: 115VAC for 230VAC) indicates the relay isopen. Replace UC control if relay does not close.

NOTE: The unitary (UC) control has a built-in short cycledelay. Ensure short cycle delay has elapsed before makingvoltage measurements.

S-9 CHECKING FAN RELAY CONTACTS

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Disconnect wire leads from terminals 2 and 4 of FanRelay Cooling and 2 and 4, 5 and 6 of Fan Relay Heating.

2. Using an ohmmeter, test between 2 and 4 - should readopen. Test between 5 and 6 - should read continuous.

3. With power ON, energize the relays.

WARNINGLine Voltage now present.

12

34

5OHMMETER

TESTING FAN RELAY4. Using an ohmmeter, test between 2 and 4 - should read

continuous . Test between 5 and 6 - should read open.5. If not as above, replace the relay.

FAN RELAY CONTACTS - UNITARY (UC) CONTROLApplies to ASXC/ASZC and DSXC/DSZC Models

Condenser fan control for the ASXC/ASZC and DSXC/DSZCmodels is fully integrated into the UC control. The controlsupports one- or two-speed PSC condenser fan motors andone- or two-speed ECM condenser fan motors.

The fan motor is controlled by two on-board relays. Connec-tion to the fan motor is via a 6-circuit plug connector. Wiringto the connector is dependant upon the type of condenser fanmotor used. See unit wiring diagram for details.CHECKING RELAY CONTACTS - PSC FAN MOTOR

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Disconnect the motor leads from 6-circuit fan motor wireharness.

2. Connect a voltmeter between circuit 3 and circuits 2 (lowspeed) or 1 (high speed).

NOTE: Circuit 3 is connected directly to L2.3. Energize the system at low or high stage.

WARNINGLine Voltage now present.

4. The measured voltage between circuit 3 and circuits 2 or1 should be approximately 0VAC, which indicates therelay contacts are closed. A voltage measurement ofapproximately 115VAC indicates the relay is open. Re-place the control if the relay checks open when it shouldbe closed. See notes and cautions below.

NOTE: Ensure any ON delays have expired before makingvoltage measurementsCAUTION: Prolonged operation with the condenser fanmotor disconnected will cause the high pressure switch totrip.

Page 65: Service Manual - R410a - RS6200006R32[1]

SERVICING

65

Status LED Status LED Description Status LED Troubleshooting InformationGreen “POW ER” Module has power Supply voltage is present at module terminalsRed “TRIP” Thermostat demand signal 1. Compressor protector is open

Y1 is present, but the 2. Outdoor unit power disconnect is opencompressor is not 3. Compressor circuit breaker or fuse(s) is openrunning 4. Broken wire or connector is not making contact

5. Low pressure switch open if present in system6. Compressor contactor has failed open

Yellow “ALERT” Long Run Time 1. Low refrigerant chargeFlash Code 1 Compressor is 2. Evaporator blower is not running

running extremely 3. Evaporator coil is frozenlong run cycles 4. Faulty metering device

5. Condenser coil is dirty6. Liquid line restriction (filter drier blocked if present in system)7. Thermostat is malfunctioning

Yellow “ALERT” System Pressure Trip 1. High head pressureFlash Code 2 Discharge or suction 2. Condenser coil poor air circulation (dirty, blocked, damaged)

pressure out of limits or 3. Condenser fan is not runningcompressor overloaded 4. Return air duct has substantial leakage

5. If low pressure switch present in system, check Flash Code 1 information

Yellow “ALERT” Short Cycling 1. Thermostat demand signal is intermittentFlash Code 3 Compressor is running 2. Time delay relay or control board defective

only briefly 3. If high pressure switch present go to Flash Code 2 information4. If low pressure switch present go to Flash Code 1 information

Yellow “ALERT” Locked Rotor 1. Run capacitor has failedFlash Code 4 2. Low line voltage (contact utility if voltage at disconnect is low)

3. Excessive liquid refrigerant in compressor4. Compressor bearings are seized

Yellow “ALERT” Open Circuit 1. Outdoor unit power disconnect is openFlash Code 5 2. Compressor circuit breaker or fuse(s) is open

3. Compressor contactor has failed open4. High pressure switch is open and requires manual reset5. Open circuit in compressor supply wiring or connections6. Unusually long compressor protector reset time due to extreme ambient temperature7. Compressor windings are damaged

Yellow “ALERT” Open Start Circuit 1. Run capacitor has failedFlash Code 6 Current only in run circuit 2. Open circuit in compressor start wiring or connections

3. Compressor start winding is damagedYellow “ALERT” Open Run Circuit 1. Open circuit in compressor run wiring or connections

Flash Code 7 Current only in start circuit 2. Compressor run winding is damagedYellow “ALERT” W elded Contactor 1. Compressor contactor has failed closed

Flash Code 8 Compressor always runs 2. Thermostat demand signal not connected to moduleYellow “ALERT” Low Voltage 1. Control circuit transformer is overloaded

Flash Code 9 Control circuit < 17VAC 2. Low line voltage (contact utility if voltage at disconnect is low)

• Flash Code number corresponds to a number of LED flashes, followed by a pause and then repeated• TRIP and ALERT LEDs flashing at same time means control circuit voltage is too low for operation.• Reset ALERT Flash code by removing 24VAC power from module• Last ALERT Flash code is displayed for 1 minute after module is powered on.

DIAGNOSTICS TABLE: 3-WIRE COMFORT ALERT™ MODULE

Page 66: Service Manual - R410a - RS6200006R32[1]

SERVICING

66

Status LED Status LED Description Status LED Troubleshooting InformationGreen “POWER” Module has power Supply voltage is present at module terminalsRed “TRIP” Thermostat demand signal 1. Compressor protector is open

Y1 is present, but the 2. Outdoor unit power disconnect is opencompressor is not 3. Compressor circuit breaker or fuse(s) is openrunning 4. Broken wire or connector is not making contact

5. Low pressure switch open if present in system6. Compressor contactor has failed open

Yellow “ALERT” Long Run Time 1. Low refrigerant chargeFlash Code 1 Compressor is 2. Evaporator blower is not running

running extremely 3. Evaporator coil is frozenlong run cycles 4. Faulty metering device

5. Condenser coil is dirty6. Liquid line restriction (filter drier blocked if present in system)7. Thermostat is malfunctioning

Yellow “ALERT” System Pressure Trip 1. High head pressureFlash Code 2 Discharge or suction 2. Condenser coil poor air circulation (dirty, blocked, damaged)

pressure out of limits or 3. Condenser fan is not runningcompressor overloaded 4. Return air duct has substantial leakage

5. If low pressure switch present in system, check Flash Code 1 information

Yellow “ALERT” Short Cycling 1. Thermostat demand signal is intermittentFlash Code 3 Compressor is running 2. Time delay relay or control board defective

only briefly 3. If high pressure switch present go to Flash Code 2 information4. If low pressure switch present go to Flash Code 1 information

Yellow “ALERT” Locked Rotor 1. Run capacitor has failedFlash Code 4 2. Low line voltage (contact utility if voltage at disconnect is low)

3. Excessive liquid refrigerant in compressor4. Compressor bearings are seized

Yellow “ALERT” Open Circuit 1. Outdoor unit power disconnect is openFlash Code 5 2. Compressor circuit breaker or fuse(s) is open

3. Compressor contactor has failed open4. High pressure switch is open and requires manual reset5. Open circuit in compressor supply wiring or connections6. Unusually long compressor protector reset time due to extreme ambient temperature7. Compressor windings are damaged

Yellow “ALERT” Open Start Circuit 1. Run capacitor has failedFlash Code 6 Current only in run circuit 2. Open circuit in compressor start wiring or connections

3. Compressor start winding is damagedYellow “ALERT” Open Run Circuit 1. Open circuit in compressor run wiring or connections

Flash Code 7 Current only in start circuit 2. Compressor run winding is damagedYellow “ALERT” Low Voltage 1. Control circuit transformer is overloaded

Flash Code 9 Control circuit < 17VAC 2. Low line voltage (contact utility if voltage at disconnect is low)

• Flash Code number corresponds to a number of LED flashes, followed by a pause and then repeated• TRIP and ALERT LEDs flashing at same time means control circuit voltage is too low for operation.• Last ALERT Flash code is displayed for 1 minute after module is powered on.

DIAGNOSTICS TABLE: 2-WIRE COMFORT ALERT™ MODULE

Page 67: Service Manual - R410a - RS6200006R32[1]

SERVICING

67

Once attached, Comfort Alert provides around-the-clockmonitoring for common electrical problems, compressordefects and broad system faults. If a glitch is detected, anLED indicator flashes the proper alert codes to help youquickly pinpoint the problem. See Diagnostic Table: 3-WireComfort Alert Module on previous page.)

Schematic Abbreviation DescriptionsHTCO High Temperature Cut Out SwitchHPCO High Pressure Cut Out SwitchLPCO Low Pressure Cut Out Switch

CC Compressor ContactorECB Electronic Control Board

(Defrost or Time Delay)

ECB

CC

HTCO LPCO HPCOComfort Alert

Diagnostics Module

Bold line shows fieldinstalled wiring

Dashed line shows thermostatdemand wiring in system withoutHTCO, HPCO, CPCO, and ECB

LOGICRCY

Y1R C

Wiring Schematic - 3-Wire Comfort Alert Module

CHECKING RELAY CONTACTS - ECM FAN MOTOR

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Disconnect the motor leads from 6-circuit fan motor wireharness.

2. Connect a voltmeter between circuit 6 and circuits 3 (lowspeed) or 1 (high speed).

NOTE: Circuit 6 is connected directly to 24VAC.3. Energize the system at low or high stage.

WARNINGLine Voltage now present.

4. The measured voltage between circuit 6 and circuits 3 or1 should be approximately 0VAC, which indicates therelay contacts are closed. A voltage measurement ofapproximately 24VAC indicates the relay is open. Re-place the control if the relay checks open when it shouldbe closed. See notes and cautions below.

5. Circuit 5 is connected to 24VAC common. The measuredvoltage between circuits 6 and 5 should be 24VAC.

NOTE: Ensure any ON delays have expired before makingvoltage measurementsCAUTION: Prolonged operation with the condenser fanmotor disconnected will cause the high pressure switch totrip.

S-10 COPELAND COMFORT ALERT™

DIAGNOSTICS - 3-WIRE MODULEApplies to ASX /ASZ and DSX/DSZ units

Comfort Alert™ is self-contained with no required externalsensors and is designed to install directly into the electricalbox of any residential condensing unit that has a CopelandScroll™ compressor inside.

Page 68: Service Manual - R410a - RS6200006R32[1]

SERVICING

68

DIAGNOSTICS - 2-WIRE MODULEApplies to ASX130[18-60]CA, ASX140[18-36]1CA,ASX140421DA, and ASX140[48-60]1BA units

Comfort Alert™ is self-contained with no required externalsensors and is designed to install directly into the electricalbox of any residential condensing unit that has a CopelandScroll™ compressor inside.Once attached, Comfort Alert™ provides around-the-clockmonitoring for common electrical problems, compressordefects and broad system faults. If a glitch is detected, anLED indicator flashes the proper alert codes to help youquickly pinpoint the problem. See Diagnostic Table: 2-WireComfort Alert™ Module on previous page.)NOTE: The 2-wire Comfort Alert™ module does not providea diagnostic code 8, Welded Contactor. Additionally, the2-wire module does not require a manual reset to clearalert codes.

Schematic Abbreviation DescriptionsHTCO High Temperature Cut Out SwitchHPCO High Pressure Cut Out SwitchLPCO Low Pressure Cut Out Switch

CC Compressor ContactorECB Electronic Control Board

(Defrost or Time Delay)

ECB

CC

HTCO LPCO HPCOComfort Alert

Diagnostics Module

Bold line shows fieldinstalled wiring

Dashed line shows thermostatdemand wiring in system withoutHTCO, HPCO, CPCO, and ECB

LOGICCY

Y1CR

Wiring Schematic - 2-Wire Comfort Alert™ Module

COPELAND COMFORT ALERTTM - UNITARY (UC) CON-TROL DIAGNOSTICS

Applies to ASXC, ASZC, DSXC, and DSZC models

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

The Copeland Comfort AlertTM diagnostics are fully integratedinto the unitary (UC) control. The UC control and integragedComfort Alert™ diagnostics provide around-the-clock moni-toring for common electrical problems, compressor defectsand broad system faults. If a problem is detected, LEDindicators flash the proper alert codes to help you quicklypinpoint the problem.The diagnostic tables on following pages provide detailedinformation regarding the system symptons, indicators (LEDand thermostat), potential problem(s), and corrective ac-tions. The diagnostic information applies to systems wiredas 24VAC traditional (legacy) systems and systems wired ascommunicating systems with the CTK0* communicatingthermostat.

Page 69: Service Manual - R410a - RS6200006R32[1]

SERVICING

69

 

Sym

ptom

s of A

bnor

mal

Ope

ratio

n (L

egac

y & C

omfo

rtN

et™ T

herm

osta

t) Di

agno

stic/

Stat

us L

ED C

odes

Fa

ult

Desc

riptio

n

Com

fort

Net

Ther

mos

tat O

nly

Poss

ible

Caus

es

Corr

ectiv

e Act

ions

Not

es &

Cau

tions

G

reen

Ye

llow

Red

Red Y

1

Mes

sage

Co

de

Very

long

run t

ime.

• Fo

ur co

nsec

utive

comp

ress

or p

rotec

tor

trips

with

avera

ge ru

n tim

e bet

ween

tri

ps g

reate

r tha

n 3 h

ours.

Com

pres

sor o

pera

ting

at hig

h spe

ed

and o

utdo

or fa

n op

erat

ing a

t low

spee

d •

Integ

rated

cont

rol m

odule

dia

gnos

tic/st

atus

LED

’s dis

play

the

indica

ted co

de.

OFF

1

Flas

h OF

F ON

if ca

ll pr

esen

t; O

FF if

no

call

• Lo

w Si

de F

ault.

LO

W S

IDE

FAUL

T 01

Low

refri

gera

nt ch

arge

. •

Restr

ictio

n in

liqu

id li

ne.

• In

door

blow

er m

otor

fa

ilure

. •

Indo

or th

ermo

stat s

et ex

treme

ly low

.

• V

erify

refri

gera

nt

char

ge; a

djus

t as

need

ed.

• Ch

eck

for r

estri

cted

liquid

line

; re

pair/

repl

ace a

s ne

eded

. •

Chec

k in

door

blo

wer

mot

or; r

epai

r/rep

lace

as ne

eded

. •

Chec

k in

door

th

erm

ostat

setti

ng.

• Tu

rn p

ower

OFF

prio

r to

repa

ir.

• Fa

ult w

ill c

lear a

fter 3

0 co

nsec

utiv

e nor

mal

cycl

es.

• Fa

ult m

ay be

clea

red b

y cy

clin

g 24V

AC to

co

ntrol

. •

Repl

ace w

ith c

orre

ct re

plac

emen

t par

t(s).

• Co

mpr

esso

r and

out

door

fan

are o

ff.

• Th

erm

ostat

dem

and

is pr

esen

t. •

Integ

rated

cont

rol m

odule

dia

gnos

tic/st

atus

LED

’s dis

play

the

indica

ted co

de.

ON

1 Fl

ash

OFF

ON if

call

pres

ent;

OFF

if no

ca

ll

• Lo

w Pr

essu

re

CO T

rip.

LPS O

PEN

01

• Lo

w re

frige

rant

char

ge.

• Re

strict

ion

in li

quid

line

. •

Indo

or bl

ower

mot

or

failu

re.

• In

door

ther

mosta

t set

extre

mely

low.

• V

erify

refri

gera

nt

char

ge; a

djus

t as

need

ed.

• Ch

eck

for r

estri

cted

liquid

line

; re

pair/

repl

ace a

s ne

eded

. •

Chec

k in

door

blo

wer

mot

or; r

epai

r/rep

lace

as ne

eded

. •

Chec

k lo

w pr

essu

re

switc

h; re

pair/

repl

ace

as ne

eded

. •

Chec

k in

door

th

erm

ostat

setti

ng.

• Tu

rn p

ower

OFF

prio

r to

repa

ir.

• Re

plac

e with

cor

rect

repl

acem

ent p

art(s

).

• Co

mpr

esso

r and

out

door

fan

are o

ff.

• Lo

w pr

essu

re sw

itch

trip 3

tim

es w

ithin

sa

me t

herm

osta

t dem

and.

Ther

mos

tat de

man

d is

pres

ent.

• In

tegrat

ed co

ntro

l mod

ule

diagn

ostic

/stat

us L

ED’s

displ

ay th

e ind

icated

code

. •

Com

fortN

et™ th

erm

ostat

“Ca

ll fo

r Se

rvice

” ico

n ill

umin

ated.

Com

fortN

et™ th

erm

ostat

scro

lls

“Che

ck A

ir Co

nditi

oner

” or

“Che

ck

Heat

Pum

p” m

essa

ge.

ON

1 Fl

ash

ON

ON if

call

pres

ent;

OFF

if no

ca

ll

• LP

CO L

ocko

ut

(3 T

rips).

LP

S LO

CKO

UT

01

• Lo

w re

frige

rant

char

ge.

• Re

strict

ion

in li

quid

line

. •

Indo

or bl

ower

mot

or

failu

re.

• In

door

ther

mosta

t set

extre

mely

low.

• V

erify

refri

gera

nt

char

ge; a

djus

t as

need

ed.

• Ch

eck

for r

estri

cted

liquid

line

; re

pair/

repl

ace a

s ne

eded

. •

Chec

k in

door

blo

wer

mot

or; r

epai

r/rep

lace

as ne

eded

. •

Chec

k lo

w pr

essu

re

switc

h; re

pair/

repl

ace

as ne

eded

. •

Chec

k in

door

th

erm

ostat

setti

ng.

• Tu

rn p

ower

OFF

prio

r to

repa

ir.

• M

ust c

lear f

ault

by

cycl

ing 2

4VAC

to

contr

ol.

• Re

plac

e with

cor

rect

repl

acem

ent p

art(s

).

Page 70: Service Manual - R410a - RS6200006R32[1]

SERVICING

70

Diag

nosti

c/St

atus

LED

Cod

es

Com

fort

Net™

Ther

mos

tat O

nly

Sym

ptom

s of A

bnor

mal

Ope

ratio

n (L

egac

y &

Com

fortN

et™

The

rmos

tat)

Gree

n Y

ellow

Re

d Re

d Y1

Faul

t D

escr

iptio

n M

essa

ge

Code

Poss

ible

Cau

ses

Corr

ectiv

e Acti

ons

Notes

& C

autio

ns

• Fo

ur c

onse

cutiv

e co

mpr

esso

r pro

tecto

r tri

ps w

ith a

vera

ge ru

n tim

e betw

een

trips

grea

ter th

an 1

minu

te an

d les

s tha

n 15

min

utes.

• Lo

w pr

essu

re an

d hi

gh pr

essu

re

switc

hes a

re cl

osed

. •

Inte

grate

d co

ntro

l mod

ule

diag

nosti

c/sta

tus L

ED’s

disp

lay th

e in

dica

ted c

ode.

OFF

2

Flas

hes

OFF

ON

if ca

ll pr

esen

t; OF

F if

no

call

• H

igh S

ide F

ault

HIG

H SI

DE

FAU

LT

02

• Bl

ocke

d co

nden

ser c

oil.

• O

utdo

or fa

n no

t run

ning

.

• Ch

eck a

nd cl

ean

cond

ense

r coi

l. •

Chec

k out

door

fan

moto

r; re

pair/

repl

ace

as n

eede

d. •

Chec

k out

door

fan

moto

r wiri

ng;

repair

/repl

ace a

s ne

eded

. •

Chec

k out

door

fan

moto

r cap

acito

r; rep

lace a

s nee

ded.

• Tu

rn po

wer O

FF p

rior

to re

pair.

Faul

t will

clea

r afte

r 4

cons

ecut

ive n

orm

al cy

cles.

• Fa

ult m

ay b

e clea

red

by

cycli

ng 2

4VAC

to

cont

rol.

• Re

plac

e with

corre

ct

replac

emen

t par

t(s).

• Co

mpr

esso

r and

out

door

fan

are o

ff.

• Th

ermo

stat d

eman

d is

pres

ent.

• In

tegr

ated

cont

rol m

odul

e di

agno

stic/

statu

s LED

’s di

splay

the

indi

cate

d cod

e.

ON

2 Fl

ashe

s OF

F O

N if

call

pres

ent;

OFF

if no

ca

ll

• H

igh P

ress

ure

CO T

rip

HPS

OPE

N 02

Bloc

ked

cond

ense

r coi

l. •

Out

door

fan

not r

unni

ng.

• Ch

eck a

nd cl

ean

cond

ense

r coi

l. •

Chec

k out

door

fan

moto

r; re

pair/

repl

ace

as n

eede

d. •

Chec

k out

door

fan

moto

r wiri

ng;

repair

/repl

ace a

s ne

eded

. •

Chec

k out

door

fan

moto

r cap

acito

r; rep

lace a

s nee

ded.

• Tu

rn po

wer O

FF p

rior

to re

pair.

Repl

ace w

ith co

rrect

rep

lacem

ent p

art(s

).

• Co

mpr

esso

r and

out

door

fan

are o

ff.

• Lo

w pr

essu

re sw

itch t

rip 3

tim

es w

ithin

sa

me t

herm

ostat

dem

and.

Ther

mosta

t dem

and

is pr

esen

t. •

Inte

grate

d co

ntro

l mod

ule

diag

nosti

c/sta

tus L

ED’s

disp

lay th

e in

dica

ted c

ode.

• Co

mfo

rtNet™

ther

mos

tat “C

all fo

r Se

rvice

” ico

n ill

umina

ted.

• Co

mfo

rtNet™

ther

mos

tat sc

rolls

“C

heck

Air

Cond

ition

er” o

r “C

heck

He

at Pu

mp”

mes

sage

.

ON

2 Fl

ashe

s ON

O

N if

call

pres

ent;

OFF

if no

ca

ll

• H

PCO

Loc

kout

(3 T

rips)

HPS

LOCK

OUT

02

• Bl

ocke

d co

nden

ser c

oil.

• O

utdo

or fa

n no

t run

ning

. •

Chec

k and

clea

n co

nden

ser c

oil.

• Ch

eck o

utdo

or fa

n mo

tor;

repa

ir/re

plac

e as

nee

ded.

• Ch

eck o

utdo

or fa

n mo

tor w

iring

; rep

air/re

plac

e as

need

ed.

• Ch

eck o

utdo

or fa

n mo

tor c

apac

itor;

replac

e as n

eede

d.

• Tu

rn po

wer O

FF p

rior

to re

pair.

Mus

t clea

r fau

lt by

cy

cling

24V

AC to

co

ntro

l. •

Repl

ace w

ith co

rrect

rep

lacem

ent p

art(s

).

• Ru

n tim

e for

last

4 cyc

les is

less

than

3

min

utes e

ach.

• Co

mpr

esso

r pro

tecto

r has

not t

rippe

d.

• Lo

w pr

essu

re an

d hi

gh pr

essu

re

switc

hes a

re cl

osed

. •

Inte

grate

d co

ntro

l mod

ule

diag

nosti

c/sta

tus L

ED’s

disp

lay th

e in

dica

ted c

ode.

OFF

3

Flas

hes

OFF

ON

if ca

ll pr

esen

t; OF

F if

no

call

• Sh

ort C

yclin

g CM

PR S

HRT

CYCL

E 03

Inter

mitt

ent t

herm

ostat

de

mand

. •

Faul

ty co

mpre

ssor

relay

.

• Ch

eck t

herm

ostat

and

therm

ostat

wiri

ng;

repair

/repl

ace a

s ne

eded

. •

Chec

k com

pres

sor

relay

ope

ratio

n;

replac

e con

trol a

s ne

eded

.

• Tu

rn po

wer O

FF p

rior

to re

pair.

Faul

t will

clea

r afte

r 4

cons

ecut

ive n

orm

al cy

cles.

• Fa

ult m

ay b

e clea

red

by

cycli

ng 2

4VAC

to

cont

rol.

• Re

plac

e with

corre

ct

replac

emen

t par

t(s).

 

Page 71: Service Manual - R410a - RS6200006R32[1]

SERVICING

71

Diag

nosti

c/St

atus

LED

Cod

es

Com

fort

Net™

Ther

mos

tat O

nly

Sym

ptom

s of A

bnor

mal

Ope

ratio

n (L

egac

y &

Com

fortN

et™

The

rmos

tat)

Gree

n Y

ellow

Re

d Re

d Y1

Faul

t D

escr

iptio

n M

essa

ge

Code

Poss

ible

Cau

ses

Corr

ectiv

e Acti

ons

Notes

& C

autio

ns

• Co

mpr

esso

r and

out

door

fan

are o

ff.

• Co

mpr

esso

r pro

tecto

r trip

s fou

r co

nsec

utive

tim

es.

• Av

erage

run

time b

etwe

en tr

ips i

s les

s th

an 1

5 sec

onds

. •

Inte

grate

d co

ntro

l mod

ule

diag

nosti

c/sta

tus L

ED’s

disp

lay th

e in

dica

ted c

ode.

• Co

mfo

rtNet™

ther

mos

tat “C

all fo

r Se

rvice

” ico

n ill

umina

ted.

• Co

mfo

rtNet™

ther

mos

tat sc

rolls

“C

heck

Air

Cond

ition

er” o

r “Ch

eck

Heat

Pum

p” m

essa

ge.

OFF

4

Flas

hes

ON

ON

if ca

ll pr

esen

t; OF

F if

no

call

• Lo

cked

Rot

or

LOCK

ED

ROTO

R 04

Comp

ress

or b

earin

gs ar

e se

ized.

Faile

d co

mpr

esso

r run

ca

pacit

or.

• Fa

ulty

run

capa

cito

r w

iring

. •

Low

line v

oltag

e.

• Ch

eck c

ompr

esso

r op

erat

ion;

repair

/repl

ace a

s ne

eded

. •

Chec

k run

capa

cito

r; rep

lace a

s nee

ded.

Chec

k wiri

ng;

repair

/repl

ace a

s ne

eded

. •

Verif

y lin

e vol

tage

is wi

thin

rang

e on r

ating

pla

te; c

onta

ct lo

cal

utilit

y is

out o

f ran

ge.

• Tu

rn po

wer O

FF p

rior

to re

pair.

Mus

t clea

r fau

lt by

cy

cling

24V

AC to

co

ntro

l. •

Repl

ace w

ith co

rrect

rep

lacem

ent p

art(s

).

• Co

mpr

esso

r and

out

door

fan

are o

ff fo

r gr

eater

than

4 ho

urs.

• Lo

w pr

essu

re an

d hi

gh pr

essu

re

switc

hes a

re cl

osed

. •

Inte

grate

d co

ntro

l mod

ule

diag

nosti

c/sta

tus L

ED’s

disp

lay th

e in

dica

ted c

ode.

• Co

mfo

rtNet™

ther

mos

tat “C

all fo

r Se

rvice

” ico

n ill

umina

ted.

• Co

mfo

rtNet™

ther

mos

tat sc

rolls

“C

heck

Air

Cond

ition

er” o

r “Ch

eck

Heat

Pum

p” m

essa

ge.

OFF

5

Flas

hes

OFF

ON

if ca

ll pr

esen

t; OF

F if

no

call

• O

pen C

ircui

t O

PEN

CIRC

UIT

05

• Po

wer i

s disc

onne

cted.

Faile

d co

mpr

esso

r pr

otect

or.

• Co

mpre

ssor

not

prop

erly

w

ired

to co

ntro

l.

• Ch

eck c

ircuit

brea

kers

and

fuse

s. •

Chec

k wiri

ng to

uni

t; rep

air/re

plac

e as

need

ed.

• Ch

eck c

ompr

esso

r; rep

air/re

plac

e as

need

ed.

• Ch

eck c

ompr

esso

r wi

ring;

repa

ir/re

plac

e as

nee

ded.

• Tu

rn po

wer O

FF p

rior

to re

pair.

Faul

t will

clea

r afte

r 1

norm

al cy

cle.

• Fa

ult m

ay b

e clea

red

by

cycli

ng 2

4VAC

to

cont

rol.

• Re

plac

e with

corre

ct

replac

emen

t par

t(s).

• Co

mpr

esso

r and

out

door

fan

are o

ff.

• Lo

w pr

essu

re an

d hi

gh pr

essu

re

switc

hes a

re cl

osed

. •

Inte

grate

d co

ntro

l mod

ule

diag

nosti

c/sta

tus L

ED’s

disp

lay th

e in

dica

ted c

ode.

• Co

mfo

rtNet™

ther

mos

tat “C

all fo

r Se

rvice

” ico

n ill

umina

ted.

• Co

mfo

rtNet™

ther

mos

tat sc

rolls

“C

heck

Air

Cond

ition

er” o

r “C

heck

He

at Pu

mp”

mes

sage

.

OFF

6

Flas

hes

OFF

ON

if ca

ll pr

esen

t; OF

F if

no

call

• O

pen S

tart

Circu

it OP

EN ST

ART

06

• Co

mpre

ssor

star

t win

ding

is

open

. •

Faile

d co

mpr

esso

r run

ca

pacit

or.

• Fa

ulty

run

capa

cito

r w

iring

. •

Comp

ress

or n

ot pr

oper

ly

wire

d to

cont

rol.

• Fa

ulty

comp

ress

or w

iring

.

• Ch

eck c

ompr

esso

r; rep

air/re

plac

e as

need

ed.

• Ch

eck r

un ca

paci

tor;

replac

e as n

eede

d.

• Ch

eck w

iring

; rep

air/re

plac

e as

need

ed.

• Tu

rn po

wer O

FF p

rior

to re

pair.

Faul

t will

clea

r afte

r 1

norm

al cy

cle.

• Fa

ult m

ay b

e clea

red

by

cycli

ng 2

4VAC

to

cont

rol.

• Re

plac

e with

corre

ct

replac

emen

t par

t(s).

• Co

mpr

esso

r and

out

door

fan

are o

ff.

• Lo

w pr

essu

re an

d hi

gh pr

essu

re

switc

hes a

re cl

osed

. •

Open

star

t circ

uit h

as b

een d

etecte

d 4

times

with

5 m

inute

delay

betw

een

each

de

tecti

on.

• In

tegr

ated

cont

rol m

odul

e di

agno

stic/

statu

s LED

’s di

splay

the

indi

cate

d cod

e. •

Com

fortN

et™ th

erm

ostat

“Call

for

Serv

ice”

icon

illum

inate

d. •

Com

fortN

et™ th

erm

ostat

scro

lls

“Che

ck A

ir Co

nditi

oner

” or “

Chec

k He

at Pu

mp”

mes

sage

.

OFF

6

Flas

hes

ON

ON

if ca

ll pr

esen

t; OF

F if

no

call

• O

pen S

tart

Circu

it Lo

ckou

t OP

EN ST

ART

LOCK

06

Comp

ress

or st

art w

indi

ng

is op

en.

• Fa

iled

com

pres

sor r

un

capa

citor

. •

Faul

ty ru

n ca

paci

tor

wiri

ng.

• Co

mpre

ssor

not

prop

erly

w

ired

to co

ntro

l. •

Faul

ty co

mpre

ssor

wiri

ng.

• Ch

eck c

ompr

esso

r; rep

air/re

plac

e as

need

ed.

• Ch

eck r

un ca

paci

tor;

replac

e as n

eede

d.

• Ch

eck w

iring

; rep

air/re

plac

e as

need

ed.

• Tu

rn po

wer O

FF p

rior

to re

pair.

Mus

t clea

r fau

lt by

cy

cling

24V

AC to

co

ntro

l. •

Repl

ace w

ith co

rrect

rep

lacem

ent p

art(s

).

 

Page 72: Service Manual - R410a - RS6200006R32[1]

SERVICING

72

Diag

nost

ic/St

atus

LED

Cod

es

Com

fort

Net™

Ther

mos

tat O

nly

Sym

ptom

s of A

bnor

mal

Ope

ratio

n (L

egac

y &

Com

fort

Net™

The

rmos

tat)

Gree

n Ye

llow

Re

d Re

d Y1

Faul

t De

scri

ptio

n M

essa

ge

Code

Poss

ible

Cau

ses

Cor

rect

ive A

ctio

ns

Note

s & C

autio

ns

• Co

mpre

ssor

and

outd

oor f

an ar

e off.

Low

pres

sure

and h

igh pr

essu

re sw

itche

s are

clos

ed.

• In

tegr

ated

contr

ol m

odul

e di

agno

stic/

statu

s LED

’s d

isplay

the

indi

cated

cod

e.

• Co

mfor

tNet

™ th

ermo

stat “

Call

for

Serv

ice”

icon

illu

min

ated.

Comf

ortN

et™

ther

mosta

t scr

olls

“Che

ck A

ir Co

nditi

oner

” or “

Chec

k He

at P

ump”

mes

sage

.

OFF

7 Fl

ashe

s O

FF

ON if

call

pres

ent;

OFF

if no

ca

ll

• O

pen

Run

Circ

uit

OPEN

RU

N 07

Com

pres

sor r

un w

indi

ng is

op

en.

• Co

mpr

esso

r not

prop

erly

wi

red

to co

ntrol

. •

Faul

ty co

mpr

esso

r wiri

ng.

• Ch

eck

com

pres

sor;

repa

ir/re

plac

e as

need

ed.

• Ch

eck

wirin

g;

repa

ir/re

plac

e as

need

ed.

• Tu

rn p

ower

OFF

prio

r to

repa

ir.

• Fa

ult w

ill cl

ear a

fter 1

no

rmal

cycl

e. •

Faul

t may

be c

leare

d by

cy

cling

24VA

C to

co

ntro

l. •

Repla

ce w

ith co

rrect

repl

acem

ent p

art(s)

.

• Co

mpre

ssor

and

outd

oor f

an ar

e off.

Low

pres

sure

and h

igh pr

essu

re sw

itche

s are

clos

ed.

• O

pen r

un ci

rcui

t has

bee

n det

ected

4

times

with

5 m

inut

e del

ay b

etwee

n ea

ch

detec

tion.

Inte

grate

d co

ntrol

mod

ule

diag

nosti

c/sta

tus L

ED’s

disp

lay th

e in

dica

ted c

ode.

Comf

ortN

et™

ther

mosta

t “Ca

ll fo

r Se

rvic

e” ic

on il

lum

inate

d.

• Co

mfor

tNet

™ th

ermo

stat s

crol

ls “C

heck

Air

Cond

ition

er” o

r “Ch

eck

Heat

Pum

p” m

essa

ge.

OFF

7 Fl

ashe

s ON

ON

if ca

ll pr

esen

t; OF

F if

no

call

• O

pen

Run

Circ

uit L

ocko

ut

OPEN

RU

N LO

CK

07

• Co

mpr

esso

r run

win

ding

is

open

. •

Com

pres

sor n

ot pr

oper

ly

wire

d to

contr

ol.

• Fa

ulty

com

pres

sor w

iring

.

• Ch

eck

com

pres

sor;

repa

ir/re

plac

e as

need

ed.

• Ch

eck

wirin

g;

repa

ir/re

plac

e as

need

ed.

• Tu

rn p

ower

OFF

prio

r to

repa

ir.

• M

ust c

lear

fault

by

cycl

ing 24

VAC

to

cont

rol.

• Re

place

with

corre

ct re

plac

emen

t part

(s).

• A

ir co

nditi

oner

/hea

t pum

p m

ay ap

pear

to

be o

perat

ing

norm

ally.

Comp

ress

or pr

otec

tor m

ay b

e ope

n (c

ompr

esso

r and

outd

oor f

an o

ff).

• In

tegr

ated

contr

ol m

odul

e di

agno

stic/

statu

s LED

’s d

isplay

the

indi

cated

cod

e.

OFF

8 Fl

ashe

s O

FF

ON if

call

pres

ent;

OFF

if no

ca

ll

• Lo

w L

ine

Vol

tage

LOW

LIN

E VO

LT

08

• Lo

w li

ne v

oltag

e.

• Ch

eck

circu

it br

eake

rs an

d fu

ses.

• Ve

rify u

nit i

s co

nnec

ted to

powe

r su

pply

as sp

ecifi

ed o

n ra

ting

plate

. •

Corre

ct lo

w lin

e vo

ltage

cond

ition

; co

ntac

t loc

al ut

ility

if

need

ed.

• Tu

rn p

ower

OFF

prio

r to

repa

ir.

• Co

ntro

l det

ects

line

volta

ge le

ss th

an 18

5 VA

C.

• A

ir co

nditi

oner

/hea

t pum

p m

ay ap

pear

to

be o

perat

ing

norm

ally.

Comp

ress

or pr

otec

tor m

ay b

e ope

n (c

ompr

esso

r and

outd

oor f

an o

ff).

• In

tegr

ated

contr

ol m

odul

e di

agno

stic/

statu

s LED

’s d

isplay

the

indi

cated

cod

e.

ON

8 Fl

ashe

s O

FF

ON if

call

pres

ent;

OFF

if no

ca

ll

• H

igh L

ine

Vol

tage

HIGH

LIN

E VO

LT

08

• Hi

gh li

ne vo

ltage

. •

Corre

ct hi

gh li

ne

volta

ge co

nditi

on;

cont

act l

ocal

utili

ty if

ne

eded

. •

Verif

y uni

t is

conn

ected

to po

wer

supp

ly as

spec

ified

on

ratin

g pl

ate.

• Co

rrect

low

line

volta

ge co

nditi

on;

cont

act l

ocal

utili

ty if

ne

eded

.

• Tu

rn p

ower

OFF

prio

r to

repa

ir.

• Co

ntro

l det

ects

line

volta

ge gr

eate

r tha

n 255

VA

C.

 

Page 73: Service Manual - R410a - RS6200006R32[1]

SERVICING

73

Diag

nosti

c/Sta

tus L

ED C

odes

Co

mfor

tNet™

Ther

most

at O

nly

Sym

ptom

s of A

bnor

mal O

pera

tion

(Leg

acy &

Com

fortN

et™ T

herm

ostat

) Gr

een

Yello

w Re

d Re

d Y1

Fault

De

scrip

tion

Mess

age

Code

Possi

ble C

auses

Co

rrec

tive A

ction

s No

tes &

Cau

tions

• Ai

r con

dition

er/he

at pu

mp m

ay ap

pear

to be

opera

ting n

ormall

y. •

Integ

rated

contr

ol mo

dule

diagn

ostic

/statu

s LED

’s dis

play t

he

indica

ted co

de.

OFF

9 Fla

shes

OFF

ON if

call

prese

nt;

OFF i

f no

call

• Lo

w Pil

ot Vo

ltage

LO

W SE

COND

VO

LT

09

• Co

ntrol

detec

ts sec

onda

ry vo

ltage

less

than 1

8 VAC

. •

Tran

sform

er ov

erloa

ded.

• Lo

w lin

e volt

age.

• Ch

eck f

use.

• Co

rrect

low se

cond

ary

volta

ge co

nditio

n. •

Chec

k tran

sform

er;

replac

e if n

eeded

.

• Tu

rn po

wer O

FF pr

ior

to rep

air.

• Fa

ult w

ill cle

ar if

secon

dary

volta

ge ris

es ab

ove 2

1VAC

. •

Repla

ce w

ith co

rrect

replac

emen

t part

(s).

• Co

mpres

sor is

off.

• Int

egrat

ed co

ntrol

modu

le dia

gnos

tic/st

atus L

ED’s

displa

y the

ind

icated

code

.

OFF

ON

ON

ON if

call

prese

nt;

OFF i

f no

call

• Co

mp Pr

otecto

r Op

en

Not d

isplay

ed

Not

displa

yed

• No

curre

nt thr

ough

run o

r sta

rt wind

ings.

• C

ompre

ssor r

un w

inding

is

open

. •

Comp

resso

r not

prope

rly

wired

to co

ntrol.

Fault

y com

presso

r wiri

ng.

• Fa

iled c

ompre

ssor r

un

capa

citor.

Fault

y run

capa

citor

wi

ring.

• Ch

eck c

ompre

ssor;

repair

/repla

ce as

ne

eded

. •

Chec

k wiri

ng;

repair

/repla

ce as

ne

eded

. •

Chec

k run

capa

citor;

rep

lace a

s nee

ded.

• Tu

rn po

wer O

FF pr

ior

to rep

air.

• Fa

ult w

ill cle

ar aft

er 1

norm

al cy

cle.

• Fa

ult m

ay be

clea

red by

cy

cling

24VA

C to

contr

ol.

• Re

place

with

corre

ct rep

lacem

ent p

art(s)

.

 

Page 74: Service Manual - R410a - RS6200006R32[1]

SERVICING

74

The line side of this capacitor is marked with "COM" and iswired to the line side of the circuit.CAPACITOR, STARTSCROLL COMPRESSOR MODELSIn most cases hard start components are not required onScroll compressor equipped units due to a non-replaceablecheck valve located in the discharge line of the compressor.However, in installations that encounter low lock rotor volt-age, a hard start kit can improve starting characteristics andreduce light dimming within the home. Only hard start kitsapproved by Amana® brand or Copeland should be used."Kick Start" and/or "Super Boost" kits are not approved startassist devices.The discharge check valve closes off high side pressure to thecompressor after shut down allowing equalization through thescroll flanks. Equalization requires only about ½ second.To prevent the compressor from short cycling, a Time DelayRelay (Cycle Protector) has been added to the low voltagecircuit.RELAY, STARTA potential or voltage type relay is used to take the start

S-11 CHECKING LOSS OF CHARGE PROTECTOR(Heat Pump Models)The loss of charge protector senses the pressure in the liquidline and will open its contacts on a drop in pressure. The lowpressure control will automatically reset itself with a rise inpressure.The low pressure control is designed to cut-out (open) atapproximately 21 PSIG. It will automatically cut-in (close) atapproximately 50 PSIG.Test for continuity using a VOM andif not as above, replace the control.

S-12 CHECKING HIGH PRESSURE CONTROL

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

The high pressure control capillary senses the pressure in thecompressor discharge line. If abnormally high condensingpressures develop, the contacts of the control open, breakingthe control circuit before the compressor motor overloads.This control is automatically reset.1. Using an ohmmeter, check across terminals of high

pressure control, with wire removed. If not continuous,the contacts are open.

3. Attach a gauge to the dill valve port on the base valve.With power ON:

WARNINGLine Voltage now present.

4. Start the system and place a piece of cardboard in frontof the condenser coil, raising the condensing pressure.

5. Check pressure at which the high pressure control cuts-out. If it cuts-out at 610 PSIG ± 10 PSIG, it is operatingnormally (See causes for high head pressure in ServiceProblem Analysis Guide). If it cuts out below thispressure range, replace the control.

S-13 CHECKING LOW PRESSURE CONTROLThe low pressure control senses the pressure in the suctionline and will open its contacts on a drop in pressure. The lowpressure control will automatically reset itself with a rise inpressure.The low pressure control is designed to cut-out (open) atapproximately 21 PSIG for heat pumps and 55 PSIG for airconditioners. It will automatically cut-in (close) at approxi-mately 50 PSIG for heat pumps and 95 PSIG for air condition-ers.Test for continuity using a VOM and if not as above, replacethe control.

S-15 CHECKING CAPACITORCAPACITOR, RUNA run capacitor is wired across the auxiliary and mainwindings of a single phase permanent split capacitor motor.The capacitors primary function is to reduce the line currentwhile greatly improving the torque characteristics of a motor.This is accomplished by using the 90° phase relationshipbetween the capacitor current and voltage in conjunction withthe motor windings, so that the motor will give two phaseoperation when connected to a single phase circuit. Thecapacitor also reduces the line current to the motor byimproving the power factor.

capacitor out of the circuit once the motor comes up to speed.This type of relay is position sensitive. The normally closedcontacts are wired in series with the start capacitor and therelay holding coil is wired parallel with the start winding. Asthe motor starts and comes up to speed, the increase involtage across the start winding will energize the start relayholding coil and open the contacts to the start capacitor.

Page 75: Service Manual - R410a - RS6200006R32[1]

SERVICING

75

A. Good Condition - indicator swings to zero and slowlyreturns to infinity. (Start capacitor with bleed resistor willnot return to infinity. It will still read the resistance of theresistor).B. Shorted - indicator swings to zero and stops there -replace.C. Open - no reading - replace. (Start capacitor wouldread resistor resistance.)

S-15B CAPACITANCE CHECKUsing a hookup as shown below, take the amperage andvoltage readings and use them in the formula:

Capacitance (MFD) = 2650 X Amperage

Voltage

WARNINGDischarge capacitor through a 20 to 30 OHMresistor before handling.

VOLTMETER

CAPACITOR

AMMETER

15 AMPFUSE

TESTING CAPACITANCE

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Discharge capacitor and remove wire leads.

WARNINGDischarge capacitor through a 20 to 30 OHMresistor before handling.

OHMMETER

CAPACITOR

TESTING CAPACITOR RESISTANCE2. Set an ohmmeter on its highest ohm scale and connect

the leads to the capacitor -

Two quick ways to test a capacitor are a resistance and acapacitance check.

STARTRELAY

CO

MH

ERM

FAN

RUNCAPACITOR

CONTACTOR

T2 T1

L1L2

STARTCAPACITOR

RED 10VIOLET 20

YELLOW 12

ORANGE 5

HARD START KIT WIRING

S-15A RESISTANCE CHECK

Page 76: Service Manual - R410a - RS6200006R32[1]

SERVICING

76

S-16A CHECKING FAN AND BLOWER MOTORWINDINGS (PSC MOTORS)

The auto reset fan motor overload is designed to protect themotor against high temperature and high amperage condi-tions by breaking the common circuit within the motor, similarto the compressor internal overload. However, heat gener-ated within the motor is faster to dissipate than the compres-sor, allow at least 45 minutes for the overload to reset, thenretest.

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Remove the motor leads from its respective connectionpoints and capacitor (if applicable).

2. Check the continuity between each of the motor leads.3. Touch one probe of the ohmmeter to the motor frame

(ground) and the other probe in turn to each lead.If the windings do not test continuous or a reading is obtainedfrom lead to ground, replace the motor.

S-16B CHECKING FAN AND BLOWER MOTOR(ECM MOTORS)

An ECM is an Electronically Commutated Motor which offersmany significant advantages over PSC motors. The ECM hasnear zero rotor loss, synchronous machine operation, vari-able speed, low noise, and programmable air flow. Becauseof the sophisticated electronics within the ECM motor, sometechnicians are intimated by the ECM motor; however, thesefears are unfounded. GE offers two ECM motor testers, andwith a VOM meter, one can easily perform basic trouble-shooting on ECM motors. An ECM motor requires power (linevoltage) and a signal (24 volts) to operate. The ECM motorstator contains permanent magnet. As a result, the shaftfeels "rough" when turned by hand. This is a characteristic ofthe motor, not an indication of defective bearings.

WARNINGLine Voltage now present.

1. Disconnect the 5-pin connector from the motor.2. Using a volt meter, check for line voltage at terminals #4

& #5 at the power connector. If no voltage is present:3. Check the unit for incoming power See section S-1.4. Check the control board, See section S-40.5. If line voltage is present, reinsert the 5-pin connector and

remove the 16-pin connector.6. Check for signal (24 volts) at the transformer.

7. Check for signal (24 volts) from the thermostat to the "G"terminal at the 16-pin connector.

8. Using an ohmmeter, check for continuity from the #1 & #3(common pins) to the transformer neutral or "C" thermo-stat terminal. If you do not have continuity, the motor mayfunction erratically. Trace the common circuits, locateand repair the open neutral.

9. Set the thermostat to "Fan-On". Using a voltmeter, checkfor 24 volts between pin # 15 (G) and common.

10. Disconnect power to compressor. Set thermostat tocall for cooling. Using a voltmeter, check for 24 volts at pin# 6 and/or #14.

11. Set the thermostat to a call for heating. Using avoltmeter, check for 24 volts at pin #2 and/or #11.

1

2

3

4

5

Lines 1 and 2 will be connected for 12OVAC Power Connector applications only

Gnd

AC Line Connection

AC Line Connection

}

11

1 9

2

3

4

5

6

7

8 16

15

14

13

12

10

OUT - OUT +

ADJUST +/- G (FAN)

Y1 Y/Y2

COOL EM Ht/W2

DELAY 24 Vac (R)

COMMON2 HEAT

W/W1 BK/PWM (SPEED)

COMMON1 O (REV VALVE)

16-PIN ECM HARNESS CONNECTOR

If you do not read voltage and continuity as described, theproblem is in the control or interface board, but not the motor.If you register voltage as described , the ECM power head isdefective and must be replaced.

Page 77: Service Manual - R410a - RS6200006R32[1]

SERVICING

77

- Con

nect

ors

are

orie

nted

"dow

n" (o

r as

reco

mm

ende

d by

equ

ipm

ent m

anuf

actu

rer).

- Arra

nge

harn

esse

s w

ith "d

rip lo

op" u

nder

mot

or.

- Is

cond

ensa

te d

rain

plu

gged

?- C

heck

for l

ow a

irflo

w (t

oo m

uch

late

nt c

apac

ity).

- Che

ck fo

r und

erch

arge

d co

nditi

on.

- Che

ck a

nd p

lug

leak

s in

retu

rn d

ucts

, cab

inet

.

*Moi

stur

e C

heck

Impo

rtan

t Not

e: U

sing

the

wro

ng m

otor

/con

trol m

odul

e vo

ids

all p

rodu

ct w

arra

ntie

s an

d m

ay p

rodu

ce u

nexp

ecte

d re

sults

.

Not

e: Y

ou m

ust u

se th

e co

rrect

repl

acem

ent c

ontro

l/mot

or m

odul

e si

nce

they

are

fact

ory

prog

ram

med

for s

peci

fic o

pera

ting

mod

es. E

ven

thou

gh th

ey lo

ok a

like,

diff

eren

t mod

ules

may

hav

e co

mpl

etel

y di

ffere

nt

func

tiona

lity.

The

EC

M v

aria

ble

spee

d m

otor

s ar

e c

Sym

ptom

Faul

t De

scri

ptio

n(s

)Po

ssib

le C

ause

sC

orre

ctiv

e A

ctio

nC

autio

ns a

nd N

ote

s

- M

otor

roc

ks

slig

htly

whe

n st

artin

g.

- T

his

is n

orm

al s

tart

-up

for

v

aria

ble

spee

d m

otor

.--

----

----

--

- N

o m

ovem

ent.

- M

anua

l dis

conn

ect s

witc

h of

f or

do

or s

witc

h op

en.

- B

low

n fu

se o

r ci

rcui

t bre

aker

. -

24

Vac

wire

s m

isw

ired.

- U

nsea

ted

pins

in w

iring

harn

ess

conn

ecto

rs.

- B

ad m

otor

/con

trol

mod

ule.

- M

oist

ure

pres

ent i

n m

otor

or

cont

rol m

odul

e.

- C

heck

230

Vac

pow

er a

t mot

or.

- C

heck

low

vol

tage

(24

Vac

R to

C)

at m

otor

. -

Che

ck lo

w v

olta

ge c

onne

ctio

ns

(G, Y

, W, R

, C)

at m

otor

. -

Che

ck f

or u

nsea

ted

pins

in c

onne

ctor

s

on m

otor

har

ness

. -

Tes

t with

a te

mpo

rary

jum

per

betw

een

R -

G.

-

- T

urn

pow

er O

FF p

rior

to r

epai

r.

W

ait 5

min

utes

aft

er

d

isco

nnec

ting

pow

er b

efor

e

ope

ning

mot

or.

- H

andl

e el

ectr

onic

mot

or/c

ontr

ol w

ith c

are.

- M

otor

roc

ks,

bu

t won

't st

art.

- L

oose

mot

or m

ount

. -

Blo

wer

whe

el n

ot ti

ght o

n m

otor

sha

ft.

- B

ad m

otor

/con

trol

mod

ule.

- C

heck

for

loos

e m

otor

mou

nt.

- M

ake

sure

blo

wer

whe

el is

tigh

t on

shaf

t. -

Per

form

mot

or/c

ontr

ol r

epla

cem

ent c

heck

,

ECM

mot

ors

only

.

- T

urn

pow

er O

FF p

rior

to r

epai

r.

W

ait 5

min

utes

aft

er

d

isco

nnec

ting

pow

er b

efor

e

ope

ning

mot

or.

- H

andl

e el

ectr

onic

mot

or/c

ontr

ol w

ith c

are.

- M

otor

osci

llate

s up

&

do

wn

whi

le

bein

g te

sted

off

of b

low

er.

- It

is n

orm

al f

or m

otor

to

osci

llate

with

no

load

on

shaf

t.--

----

----

--

- V

arie

s up

and

dow

n

or in

term

itten

t.

- V

aria

tion

in 2

30 V

ac to

mot

or.

- U

nsea

ted

pins

in w

iring

har

ness

conn

ecto

rs.

- E

rrat

ic C

FM c

omm

and

from

"B

K"

term

inal

. -

Impr

oper

ther

mos

tat c

onne

ctio

n or

set

ting.

- M

oist

ure

pres

ent i

n m

otor

/con

trol

mod

ule.

- C

heck

line

vol

tage

for

var

iatio

n or

"sa

g".

- C

heck

low

vol

tage

con

nect

ions

(G

, Y, W

, R, C

) at

mot

or, u

nsea

ted

pins

in m

otor

ha

rnes

s co

nnec

tors

. -

Che

ck-o

ut s

yste

m c

ontr

ols

- Th

erm

osta

t. -

Per

form

Moi

stur

e C

heck

.*

- T

urn

pow

er O

FF p

rior

to r

epai

r.

- "

Hun

ts"

or "

puff

s" a

t

high

CFM

(sp

eed)

.

- In

corr

ect o

r di

rty

filte

r(s)

. -

Inco

rrec

t sup

ply

or r

etur

n du

ctw

ork.

- In

corr

ect b

low

er s

peed

set

ting.

- D

oes

rem

ovin

g pa

nel o

r fil

ter

re

duce

"pu

ffin

g"?

- C

heck

/rep

lace

filt

er.

- C

heck

/cor

rect

duc

t res

tric

tions

. -

Adj

ust t

o co

rrec

t blo

wer

spe

ed s

ettin

g.

- T

urn

pow

er O

FF p

rior

to r

epai

r.

Trou

bles

hoot

ing

Cha

rt fo

r GE

/Reg

al-B

eloi

t EC

M V

aria

ble

Spe

ed A

ir C

ircul

ator

Blo

wer

Mot

ors

- M

otor

won

't

star

t.

- M

otor

sta

rts,

bu

t run

s

erra

tical

ly.

CH

AR

T C

ON

TIN

UED

ON

NEX

T PA

GE

Page 78: Service Manual - R410a - RS6200006R32[1]

SERVICING

78

- Con

nect

ors

are

orie

nted

"dow

n" (o

r as

reco

mm

ende

d by

equ

ipm

ent m

anuf

actu

rer).

- Arra

nge

harn

esse

s w

ith "d

rip lo

op" u

nder

mot

or.

- Is

cond

ensa

te d

rain

plu

gged

?- C

heck

for l

ow a

irflo

w (t

oo m

uch

late

nt c

apac

ity).

- Che

ck fo

r und

erch

arge

d co

nditi

on.

- Che

ck a

nd p

lug

leak

s in

retu

rn d

ucts

, cab

inet

.

*Moi

stur

e C

heck

Impo

rtan

t Not

e: U

sing

the

wro

ng m

otor

/con

trol m

odul

e vo

ids

all p

rodu

ct w

arra

ntie

s an

d m

ay p

rodu

ce u

nexp

ecte

d re

sults

.

Not

e: Y

ou m

ust u

se th

e co

rrect

repl

acem

ent c

ontro

l/mot

or m

odul

e si

nce

they

are

fact

ory

prog

ram

med

for s

peci

fic o

pera

ting

mod

es. E

ven

thou

gh th

ey lo

ok a

like,

diff

eren

t mod

ules

may

hav

e co

mpl

etel

y di

ffere

nt

func

tiona

lity.

The

EC

M v

aria

ble

spee

d m

otor

s ar

e c

CH

AR

T C

ON

TIN

UED

FR

OM

PR

EVIO

US

PAG

E.

Sym

ptom

Fau

lt De

scr

iptio

n(s)

Pos

sib

le C

aus

esC

orr

ecti

ve A

ctio

nC

auti

ons

and

No

tes

- S

tays

at l

ow C

FM d

espi

te

syst

em c

all f

or c

ool

or

hea

t CFM

.

- 2

4 V

ac w

ires

mis

wire

d or

loos

e. -

"R

" m

issi

ng/n

ot c

onne

cted

at m

otor

. -

Fan

in d

elay

mod

e.

- C

heck

low

vol

tage

(Th

erm

osta

t)

wire

s an

d co

nnec

tions

. -

Ver

ify f

an is

not

in d

elay

mod

e -

w

ait u

ntil

dela

y co

mpl

ete.

- P

erfo

rm m

otor

/con

trol

rep

lace

men

t

chec

k, E

CM

mot

ors

only

.

- T

urn

pow

er O

FF p

rior

to r

epai

r.

W

ait 5

min

utes

aft

er

d

isco

nnec

ting

pow

er b

efor

e

ope

ning

mot

or.

- H

andl

e el

ectr

onic

mot

or/c

ontr

ol

w

ith c

are.

- S

tays

at h

igh

CFM

. -

"R

" m

issi

ng/n

ot c

onne

cted

at m

otor

. -

Fan

in d

elay

mod

e.

- Is

fan

in d

elay

mod

e? -

wai

t unt

il de

lay

time

com

plet

e. -

Per

form

mot

or/c

ontr

ol r

epla

cem

ent c

heck

, EC

M

mot

ors

only

.

- T

urn

pow

er O

FF p

rior

to r

epai

r.

W

ait 5

min

utes

aft

er

d

isco

nnec

ting

pow

er b

efor

e

ope

ning

mot

or.

- H

andl

e el

ectr

onic

mot

or/c

ontr

ol

w

ith c

are.

- B

low

er w

on't

shut

off

. -

Cur

rent

leak

age

from

con

trol

s

into

G, Y

, or

W.

- C

heck

for

Tria

c sw

itche

d t's

tat

or

sol

id s

tate

rel

ay.

- T

urn

pow

er O

FF p

rior

to r

epai

r.

- A

ir no

ise.

- H

igh

stat

ic c

reat

ing

high

blo

wer

spe

ed.

- In

corr

ect s

uppl

y or

ret

urn

duct

wor

k. -

Inco

rrec

t or

dirt

y fil

ter(

s).

- In

corr

ect b

low

er s

peed

set

ting.

- C

heck

/rep

lace

filt

er.

- C

heck

/cor

rect

duc

t res

tric

tions

. -

Adj

ust t

o co

rrec

t blo

wer

spe

ed s

ettin

g. -

Tur

n po

wer

OFF

prio

r to

rep

air.

- N

oisy

blo

wer

or

cabi

net.

- L

oose

blo

wer

hou

sing

, pan

els,

etc

. -

Hig

h st

atic

cre

atin

g hi

gh b

low

er

spee

d. -

Air

leak

s in

duc

twor

k, c

abin

ets,

or

pan

els.

- C

heck

for

loos

e bl

ower

hou

sing

,

pane

ls, e

tc.

- C

heck

for

air

whi

stlin

g th

ru s

eam

s in

du

cts,

cab

inet

s or

pan

els.

- C

heck

for

cab

inet

/duc

t def

orm

atio

n.

- T

urn

pow

er O

FF p

rior

to r

epai

r.

- "

Hun

ts"

or "

puff

s" a

t

high

CFM

(sp

eed)

.

- H

igh

stat

ic c

reat

ing

high

blo

wer

spe

ed.

- In

corr

ect o

r di

rty

filte

r(s)

. -

Inco

rrec

t sup

ply

or r

etur

n du

ctw

ork.

- In

corr

ect b

low

er s

peed

set

ting.

- D

oes

rem

ovin

g pa

nel o

r fil

ter

re

duce

"pu

ffin

g"?

- C

heck

/rep

lace

filt

er.

- C

heck

/cor

rect

duc

t res

tric

tions

. -

Adj

ust t

o co

rrec

t blo

wer

spe

ed s

ettin

g.

- T

urn

pow

er O

FF p

rior

to r

epai

r.

- E

vide

nce

of

Moi

stur

e.

- M

otor

fai

lure

or

m

alfu

nctio

n ha

s

occu

rred

and

moi

stur

e

is p

rese

nt.

- M

oist

ure

in m

otor

/con

trol

mod

ule.

- R

epla

ce m

otor

and

per

form

M

oist

ure

Che

ck.*

- T

urn

pow

er O

FF p

rior

to r

epai

r.

W

ait 5

min

utes

aft

er

d

isco

nnec

ting

pow

er b

efor

e

ope

ning

mot

or.

- H

andl

e el

ectr

onic

mot

or/c

ontr

ol

w

ith c

are.

- E

xces

sive

no

ise.

Trou

bles

hoot

ing

Cha

rt fo

r GE

/Reg

al-B

eloi

t EC

M V

aria

ble

Spe

ed A

ir C

ircul

ator

Blo

wer

Mot

ors

- M

otor

sta

rts,

bu

t run

s

erra

tical

ly.

Page 79: Service Manual - R410a - RS6200006R32[1]

SERVICING

79

S-16C CHECKING ECM MOTOR WINDINGS

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Disconnect the 5-pin and the 16-pin connectors from theECM power head.

2. Remove the 2 screws securing the ECM power head andseparate it from the motor.

3. Disconnect the 3-pin motor connector from the powerhead and lay it aside.

4. Using an ohmmeter, check the motor windings forcontinuity to ground (pins to motor shell). If the ohmmeterindicates continuity to ground, the motor is defective andmust be replaced.

5. Using an ohmmeter, check the windings for continuity(pin to pin). If no continuity is indicated, the thermal limit(over load) device may be open. Allow motor to cool andretest.

16-pin connector

5-pin connector

3-pin motorconnector

S-16D ECM CFM ADJUSTMENTS MBE / AEPFMBE MOTORThis section references the operation characteristics of theMBE/AEPF models motor only. The ECM control board isfactory set with the dipswitch #4 in the “ON” position and allother dipswitches are factory set in the “OFF” position. WhenMBE/AEPF are used with 2-stage cooling units, dipswitch#4 should be in the "OFF" position.For most applications, the settings are to be changedaccording to the electric heat size and the outdoor unitselection.The MBE/AEPF products use a General Electric ECMTM

motor. This motor provides many features not available onthe traditional PSC motor. These features include:

• Improved Efficiency• Constant CFM• Soft Start and Stop• Improved Humidity Control

MOTOR SPEED ADJUSTMENTEach ECM™ blower motor has been preprogrammed foroperation at 4 distinct airflow levels when operating inCooling/Heat Pump mode or Electric Heat mode. These 4distinct levels may also be adjusted slightly lower or higherif desired. The adjustment between levels and the trimadjustments are made by changing the dipswitch(s) either toan "OFF" or "ON" position.

DIPSWITCH FUNCTIONSThe MBE / AEPF air handler motors have an electroniccontrol that contains an eight (8) position dip switch. Thefunction of these dipswitches are shown in Table 1.

Dipswitch Number Function123 N/A4 Indoor Thermostat5678

Cooling & Heat Pump CFM

CFM Trim Adjust

Electric Heat

Table 1CFM DELIVERYTables 2, 3, 5 and 6 show the CFM output for dipswitchcombinations 1-2, and 5-6.

Model Switch 1 Switch 2 CFMOFF OFF 1,200ON OFF 1,000OFF ON 800ON ON 600OFF OFF 1,600ON OFF 1,400OFF ON 1,200ON ON 1,000OFF OFF 2,000ON OFF 1,800OFF ON 1,600ON ON 1,200

MBE1200

MBE1600

MBE2000

Electric Heat Operation

Table 2

Page 80: Service Manual - R410a - RS6200006R32[1]

SERVICING

80

Model Switch 5 Switch 6 CFMOFF OFF 1,200ON OFF 1,000OFF ON 800ON ON 600OFF OFF 1,600ON OFF 1,400OFF ON 1,200ON ON 1,000OFF OFF 2,000ON OFF 1,800OFF ON 1,600ON ON 1,200

MBE1200

MBE1600

MBE2000

Cooling/Heat Pump Operation

Table 3

THERMOSTAT “FAN ONLY” MODEDuring Fan Only Operations, the CFM output is 30% of thecooling setting.

CFM TRIM ADJUSTMinor adjustments can be made through the dip switchcombination of 7-8. Table 4 shows the switch position for thisfeature.NOTE: The airflow will not make the decreasing adjustmentin Electric Heat mode.

C FM S w itc h 7 S w itc h 8+ 1 0 % O N O F F-1 5 % O F F O N

Table 4HUMIDITY CONTROLWhen using a Humidstat (normally closed), cut jumper PJ6on the control board. The Humidstat will only affect coolingairflow by adjusting the Airflow to 85%.

TWO STAGE HEATINGWhen using staged electric heat, cut jumper PJ4 on thecontrol board.

AEPF DIPSWITCH FUNCTIONS

Dipswitch 1/2 & 7/8AEPF 1830

HeatingElement

(kw) 1 2 7 8

UP TO 10 OFF OFF OFF OFF 1100 1210

UP TO 10 ON OFF OFF OFF 890 935

5 OFF ON OFF OFF 700 770

AEPF3036 / 3137 / 4260HeatingElement

(kw) 1 2 7 8

UP TO 20 OFF OFF OFF OFF 2050 2150

UP TO 20 ON OFF OFF OFF 1750 1835

UP TO 15 OFF ON OFF OFF 1600 1680

UP TO 10 ON ON OFF OFF 1200 1260

UP TO 10 ON ON OFF ON 1020 1070

Heat PumpWith Backup

SwitchPosition

SwitchPosition

SwitchPosition

SwitchPosition

EmergencyBackup

Heat PumpWith Backup

EmergencyBackup

Dipswitch 5/6 & 7/8

AEPF 1830

5 6 7 8 Cooling Heat PumpOFF OFF OFF OFF 1100 1100

ON OFF OFF OFF 800 800

OFF ON OFF OFF 600 600

5 6 7 8 Cooling Heat PumpOFF OFF OFF OFF 1800 1800

ON OFF OFF OFF 1580 1580

OFF ON OFF OFF 1480 1480

ON ON OFF OFF 1200 1200

ON ON OFF ON 1020 1020

SwitchPosition

SwitchPosition

Indoor Airflow

SwitchPosition

SwitchPosition

Indoor Airflow

AEPF3036 / 3137 / 4260

Page 81: Service Manual - R410a - RS6200006R32[1]

SERVICING

81

S-16E BLOWER PERFORMANCE DATA

SPEED STATIC MBR800**-*SCFM

MBR1200**-*SCFM

MBR1600**-*SCFM

MBR2000**-*SCFM

0.1 1,240 1,500 1,800 2,1600.2 1,170 1,460 1,740 2,0800.3 1,120 1,360 1,680 1,9900.4 1,060 1,280 1,610 1,8900.5 980 1,200 1,520 1,7900.6 900 1,110 1,430 1,6900.1 900 1,380 1,540 1,7300.2 850 1,320 1,490 1,6700.3 790 1,270 1,450 1,5900.4 740 1,200 1,400 1,5200.5 680 1,140 13,560 1,4200.6 605 1,040 1,280 1,3200.1 650 1,170 1,130 1,5200.2 590 1,130 1,100 1,4500.3 540 1,080 1,070 1,3600.4 500 1,020 1,030 1,2900.5 430 950 990 1,2000.6 330 830 930 1,090

HIGH

MEDIUM

LOW

NOTE: External static is for blower @ 230 Volts. It does not include Coil, Air Filter or Electric Heaters.

MOTOR CONNECTIONS

C L G N

1 2 3 4 5

High VoltageConnections

3/16"

Low Voltage Connections1/4”

S-16F CHECKING HIGH EFFICIENCY MOTORSThe motor is a one piece, fully encapsulated, 3 phasebrushless DC (single phase AC input) motor with ball bearingconstruction.

1. Using a voltmeter, check for 230 volts to the motorconnections L and N. If 230 volts is present, proceed tostep 2. If 230 volts is not present, check the line voltagecircuit to the motor.

2. Using a voltmeter, check for 24 volts from terminal C toeither terminal 1, 2, 3, 4, or 5, depending on which tap isbeing used, at the motor. If voltage present, proceedtostep 3. If no voltage, check 24 volt circuit to motor.

3. If voltage was present in steps 1 and 2, the motor hasfailed and will need to be replaced.

Note: When replacing motor, ensure the belly band isbetween the vents on the motor and the wiring has theproper drip loop to prevent condensate from entering themotor.

Page 82: Service Manual - R410a - RS6200006R32[1]

SERVICING

82

S-16G CHECKING EMERSON ULTRATECHTM

ECM MOTORSDESCRIPTIONThe AVPTC and MBVC models utilize an Emerson, 4-wirevariable speed ECM blower motor. The ECM blower motorprovides constant CFM.The motor is a serially communicating variable speed motor.Only four wires are required to control the motor: +Vdc,Common, Receive, and Transmit.The +Vdc and Common wires provide power to the motor'slow voltage control circuits. Typical supply voltage is 9-15volts DC.

GENERAL CHECKS/CONSIDERATIONS1. Check power supply to the air handler or modular blower.

Ensure power supply is within the range specified onrating plate. See section S-1.

2. Check motor power harness. Ensure wires are continu-ous and make good contact when seated in the connec-tors. Repair or replace as needed.

3. Check motor control harness. Ensure wires are continu-ous and make good contact when seated in the connec-tors. Repair or replace as needed.

4. Check thermostat and thermostat wiring. Ensure thermo-stat is providing proper cooling/heating/continuous fandemands. Repair or replace as needed.

5. Check blower wheel. Confirm wheel is properly seated onmotor shaft. Set screw must be on shaft flat and torquedto 165 in-lbs minimum. Confirm wheel has no broken orloose blades. Repair or replace as needed.

6. Ensure motor and wheel turn freely. Check for interfer-ence between wheel and housing or wheel and motor.Repair or replace as needed.

7. Check housing for cracks and/or corrosion. Repair orreplace as needed.

8. Check motor mounting bracket. Ensure mouting bracketis tightly secured to the housing. Ensure bracket is notcracked or broken.

Emerson UltraCheck-EZTM Diagnostic ToolThe Emerson UltraCheck-EZTM diaganostic tool may be usedto diagnose the ECM motor.

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

To use the diagnostic tool, perform the following steps:1. Disconnect power to the air handler.2. Disconnect the 4-circuit control harness from the motor.3. Plug the 4-circuit connector from the diagnostic tool into

the motor control connector.4. Connect one alligator clip from the diagnostic tool to a

ground source.5. Connect the other alligator clip to a 24VAC source.NOTE: The alligator clips are NOT polarized.NOTE: The UltraCheck-EZTM diagnostic tool is equippedwith a nonreplaceable fuse. Connecting the tool to a sourceother than 24VAC could damage the tool and cause the fuseto open. Doing so will render the diagnostic tool inoperable.6. Turn on power to air handler or modular blower.

WARNINGLine Voltage now present.

7. Depress the orange power button on the diagnostic toolto send a run signal to the motor. Allow up to 5 secondsfor the motor to start.

NOTE: If the orange power button does not illuminate whendepressed, the tool either has an open fuse or is not properlyconnected to a 24VAC source.8. The green LED on the diagnostic tool will blink indicating

communications between the tool and motor. See tablebelow for indications of tool indicators and motor actions.Replace or repair as needed.

P ow e r Button

Gre e n LED

M otor Action Indica tion(s)

OFF OFFNot

Rotating

Confirm 24V A C to UltraCheck-E ZTM tool.If 24V A C is confirm ed, diagnos tic tool is inoperable.

ON Blink ing RotatingM otor and control/end bell are func tioning properly .

ON OFF Rotating Replace m otor control/end bell.

ON Blink ing Not Rotating

Check m otor (see Motor Check s below).

ON OFF Not Rotating

Replace m otor control/end bell; verify m otor (see Motor Check s below).

9. Depress the orange power button to turn off motor.10. Disconnect power. Disconnect diagnostic tool.

Page 83: Service Manual - R410a - RS6200006R32[1]

SERVICING

83

11. Reconnect the 4-wire harness from control board tomotor.

Electrical Checks - High Voltage Power Circuits

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Disconnect power to air handler or modular blower.2. Disconnect the 5-circuit power connector to the ECM

motor.3. Turn on power to air handler or modular.

WARNINGLine Voltage now present.

4. Measure voltage between pins 4 and 5 on the 5-circuitconnector. Measured voltage should be the same as thesupply voltage to the air handler or modular.

1

2

3

4

5

Lines 1 and 2 will be connected for 12OVAC Power Connector applications only

Gnd

AC Line Connection

AC Line Connection

}

5. Measure voltage between pins 4 and 3. Voltage shouldbe approximately half of the voltage measured in step 4.

6. Measure voltage between pins 5 and 3. Voltage shouldbe approximately half of the voltage measured in step 4.

7. If no voltage is present, check supply voltage to air handleror modular blower. See section S-1.

8. Disconnect power to air handler or modular blower.Reconnect the 5-circuit power harness disconnected instep 2.

Electrical Checks - Low Voltage Control Circuits1. Turn on power to air handler or modular.

WARNINGLine Voltage now present.

2. Check voltage between pins 1 and 4 on the 4-wire motorcontrol harness between the motor and control board.Voltage should be between 9 and 15 VDC.

3. If no voltage is present, check control board. See sectionS-40A.

Motor Control/End Bell Checks

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Disconnect power to air handler or modular blower.NOTE: Motor contains capacitors that can hold a charge forseveral minutes after disconnecting power. Wait 5 minutesafter removing power to allow capacitors to discharge.2. Disconnect the motor control harness and motor power

harness.3. Remove the blower assembly from the air handler or

modular blower.4. Remove the (3) screws securing the control/end bell to the

motor. Separate the control/end bell. Disconnect the 3-circuit harness from the control/end bell to remove thecontrol/end bell from the motor.

5. Inspect the NTC thermistor inside the control/end bell(see figure below). Replace control/end bell if thermistoris cracked or broken.

Page 84: Service Manual - R410a - RS6200006R32[1]

SERVICING

84

6. Inspect the large capacitors inside the control/end bell(see figure below). Replace the control/end bell if any ofthe capacitors are bulging or swollen.

7. Locate the 3-circuit connector in the control/end bell.Using an ohmmeter, check the resistance between eachterminal in the connector. If the resistance is 100kW orgreater, the control/end bell is functioning properly. Re-place the control/end bell if the resistance is lower than100kW.

8. Reassemble motor and control/end bell in reverse ofdisassembly. Replace blower assembly into air handleror modular blower.

Motor Checks

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Disconnect power to air handler or modular blower.NOTE: Motor contains capacitors that can hold a charge forseveral minutes after disconnecting power. Wait 5 minutesafter removing power to allow capacitors to discharge.2. Disassemble motor as described in steps 2 through 4

above.3. Locate the 3-circuit harness from the motor. Using an

ohmmeter, measure the resistance between each motorphase winding. The resistance levels should be equal.Replace the motor if the resistance levels are unequal,open circuited or short circuited.

4. Measure the resistance between each motor phasewinding and the motor shell. Replace the motor if anyphase winding is short circuited to the motor shell.

5. Reassemble motor and control/end bell in reverse ofdisassembly. Replace blower assembly into air handleror modular blower.

S-16H ECM CFM ADJUSTMENTS AVPTC/MBVCThis section references the operation characteristics of theMBVC models. The MBVC models utilize an integrated airhandler control. The air handler control provides ECMblower motor control and includes all dipswitches neces-sary to set up the cooling, heat pump and electric airflowcharacteristics.The control has three banks of dipswitches: a bank forcooling airflow and trim adjustment, a bank for selecting oneof (4) enhancement profiles and enabling dehumidification,and a bank for selecting the installed electric heater kit size.Adjustments are made by selecting the appropriate ON/OFF combinations of the dipswitches. The dipswitchesalong with their functions are shown in the figures below.Cooling Airflow Dipswitches - Used to set the desiredcooling airflow

Cooling Airflow Speed Tap (* indicates factory setting)

Tap A

1

OFF ON

2

Tap B

1

OFF ON

2

Tap C

1

OFF ON

2

Tap D*

1

OFF ON

2

Airflow Adjust Dipswitches - Used to adjust the airflow +/-10%

Airflow Adjust Taps (* indicates factory sett ing)

Normal*

3

OFF ON

4

+10%

3

OFF ON

4

-10%

3

OFF ON

4

Normal

3

OFF ON

4

Ramping Profile Dipswitches - Used to select a comfortprofile for the cooling mode.

Cooling Airflow Ramping Profiles (* indicates factory setting)

Tap A*

5

OFF ON

6

Tap B

5

OFF ON

6

Tap C

5

OFF ON

6

Tap D

5

OFF ON

6

Page 85: Service Manual - R410a - RS6200006R32[1]

SERVICING

85

Dehumidification Disable/Enable Dipswitch - Reduces cool-ing airflow by ~ 15% when enabled AND when used with ahumidistat (such as DEHUM1). Airflow is reduced when acall for cooling is present and the humidistat is open.

7 8

OFF ON

DEHUM

Unused Move to the ON position to enable dehumidification

Cool Adjust ProfileSelection Selection Selection Switches Switches Switches

D ON ON ON ON ON ON

C OFF ON OFF ON OFF ON

(1) Select model and desiredhigh stage cooling airflow. Determine the cooresponding tap( A, B, C, or D ). Set dip switches 1 and 2 to the appropriateON / OFF positions. (2) Select model and installed electricheater size. Set switches 9, 10, and 11 to the appropriateON/OFF positions. (3) Select the airflow adjustment factor tapA and D are 0%; Tap B is +10%; Tap C -10%. Set dip switches 3and 4 to the appropriate ON / OFF positions.

Select desired Comfort Mode profile(see profiles above). Set switches 5 and 6 to the approriateON / OFF positions.

A ------- -------- 60 sec/100%

B ON OFF ON OFF ON OFF

TAP 1 2 3 4 5 6

To set airflow:

D 30 sec/50% 7.5 min/82% 30 sec/50%

A OFF OFF OFF OFF OFF OFF

0140A00045

Speed Selection Dip Switches

B ------- 30 sec/50% 60 sec/100%

To set Comfort Mode:

Profiles Pre-Run Short-Run OFF Delay

C ------- 7.5 min/82% 60 sec/100%

Model Tap Low Stage High Stage Cool Cool

MBVC1200 *A 400 600B 540 800C 670 1000D 800 1200

MBVC1600 *A 670 1000B 800 1200C 940 1400D 1070 1600

* MBVC2000A 800 1200B 1070 1600C 1200 1800D 1340 2000

Htr Kw 9 10 11 MBVC1200* MBVC16000* MBVC2000*

3 ON ON ON 600 800 800

5 ON ON OFF 600 800 800

6 ON OFF ON 635 800 800

8 ON OFF OFF 740 1000 1000

10 OFF ON ON 1000 1000 1200

15 OFF ON OFF 1400 1500 1500

20 OFF OFF ON NR NR 2000

MBVC Airflow Table

Electric Heater Airflow - Airflow for installed electric heatersis set by adjusting the dipswitches to the appropriate heatersize.

Electric Heating Airflow (* indicates factory setting)

21 kW*

9

OFF ON

10

11

20 kW

9

OFF ON

10

11

15 kW

9

OFF ON

10

11

10 kW

9

OFF ON

10

11

8 kW

9

OFF ON

10

11

6 kW

9

OFF ON

10

11

5 kW

9

OFF ON

10

11

3 kW

9

OFF ON

10

11

Electric Heating Airflow (* indicates factory setting)

The table below indicates the airflow that corresponds to theavailable dipswitch settings.

Page 86: Service Manual - R410a - RS6200006R32[1]

SERVICING

86

NOTE: When 8kW and 10kW heat kits are used with anAVPTC1830 and AVPTC313, matched with 2-ton outdoorunit, see Note 1below.

1 Set Heater Kit dip switches 9, 10 and 11 to 6kW setting(9-ON, 10-OFF, 11-ON) to obtain 840 CFM.

AVPTC Airflow Table

Profiles 5 6A OFF OFFB ON OFFC OFF OND ON ON30 sec/50% 7.5 mins/82% 30 sec/50%

------- 30 sec/50% 60 sec/100%------- 7.5 mins/82% 60 sec/100%

ProfileSelectionSwitches

Pre-Run Short-Run Off Delay------- ------- 60 sec/100%

Tap 1 2 TRIM 3 4A OFF OFF 0% OFF OFFB ON OFF + 10% ON OFFC OFF ON - 10% OFF OND ON ON 0% ON ON

AdjustSelectionSwitches

CoolSelectionSwitches

Speed Selection Dip Switches

TO SET AIRFLOW:1.Select appropriate model from Cooling/Heat Pump Airflow Table. Based on desired Airflow for your application select corresponding tap (A,B,C or D). Set dip switches 1 & 2 to the appropriate ON/OFF positions.2. Select appropriate Airflow adjustment factor for application (0%. +10%, -10%). Set dip switches 3 & 4 to the appropriate ON/OFF positions.3. If installed with Heater Kit: Using Electric Heat Airflow Table, set dip switches 9, 10 and 11 to the appropriate ON/OFF positions based on Heater kit installed. If installed without Heater Kit: Ensure dip switches 9, 10 and 11 are set to a valid heater kit selection. Example: The only valid heater kits for AVPTC183014* applications are 3, 5, 6, 8 and 10 kW. Failure to do so will result in a Heater Kit error code.

TO SET COMFORT MODE:Select desired Comfort Mode profile (see profiles above). Set switches5 and 6 to the appropriate ON/OFF positions.

TapLow

StageCool

High StageCool

A 420 630B 560 840C 700 1040A 410 610B 560 830C 700 1040D 830 1240A 810 1210B 940 1410C 1050 1560D 1210 1800

Htr kW 9 10 11 AVPTC183014*

AVPTC313714*

AVPTC426014*

3 ON ON ON 630 610 6005 ON ON OFF 730 710 6806 ON OFF ON 840 840 7908 ON OFF OFF 1080 1060 99010 OFF ON ON 1270 1260 119015 OFF ON OFF NR 1470 139020 OFF OFF ON NR NR 158021 OFF OFF OFF NR NR 1580

NOTE: Airflow data shown applies to the emergency heat mode (electric heat only) in either non-communicating mode operation or fully communicating mode operation.

Cooling/Heat Pump Airflow Table

Electr ic Heat Airflow Table

NOTE: Airflow data shown applies to non-communicating mode operation only. For a fully communicating system, please see the outdoor unit's installation instructions for cooling and heat pump airflow data. See ComfortNet™ System - Airflow Consideration section for details.

Model

AVPTC183014*

AVPTC313714*

AVPTC426014*

Page 87: Service Manual - R410a - RS6200006R32[1]

SERVICING

87

S-17 CHECKING COMPRESSOR

WARNINGHermetic compressor electrical terminal venting canbe dangerous. When insulating material whichsupports a hermetic compressor or electrical terminalsuddenly disintegrates due to physical abuse or as aresult of an electrical short between the terminal andthe compressor housing, the terminal may beexpelled, venting the vapor and liquid contents of thecompressor housing and system.

If the compressor terminal PROTECTIVE COVER and gasket(if required) are not properly in place and secured, there is aremote possibility if a terminal vents, that the vaporous andliquid discharge can be ignited, spouting flames several feet,causing potentially severe or fatal injury to anyone in its path.This discharge can be ignited external to the compressor ifthe terminal cover is not properly in place and if the dischargeimpinges on a sufficient heat source.Ignition of the discharge can also occur at the venting terminalor inside the compressor, if there is sufficient contaminant airpresent in the system and an electrical arc occurs as theterminal vents.Ignition cannot occur at the venting terminal without thepresence of contaminant air, and cannot occur externallyfrom the venting terminal without the presence of an externalignition source.Therefore, proper evacuation of a hermetic system is essen-tial at the time of manufacture and during servicing.To reduce the possibility of external ignition, all open flame,electrical power, and other heat sources should be extin-guished or turned off prior to servicing a system.If the following test indicates shorted, grounded or openwindings, see procedures S-19 for the next steps to be taken.

S-17A RESISTANCE TESTEach compressor is equipped with an internal overload.The line break internal overload senses both motor amperageand winding temperature. High motor temperature or amper-age heats the disc causing it to open, breaking the commoncircuit within the compressor on single phase units.Heat generated within the compressor shell, usually due torecycling of the motor, high amperage or insufficient gas tocool the motor, is slow to dissipate. Allow at least three tofour hours for it to cool and reset, then retest.Fuse, circuit breaker, ground fault protective device, etc. hasnot tripped -

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Remove the leads from the compressor terminals.

See warnings S-17 before removing compressorterminal cover.

2. Using an ohmmeter, test continuity between terminals S-R, C-R, and C-S, on single phase units or terminals T2,T2 and T3, on 3 phase units.

S R

C

COMPOHMMETER

TESTING COMPRESSOR WINDINGSIf either winding does not test continuous, replace thecompressor.NOTE: If an open compressor is indicated, allow ample timefor the internal overload to reset before replacing compressor.

S-17B GROUND TESTIf fuse, circuit breaker, ground fault protective device, etc.,has tripped, this is a strong indication that an electricalproblem exists and must be found and corrected. The circuitprotective device rating must be checked, and its maximumrating should coincide with that marked on the equipmentnameplate.With the terminal protective cover in place, it is acceptable toreplace the fuse or reset the circuit breaker ONE TIME ONLYto see if it was just a nuisance opening. If it opens again, DONOT continue to reset.Disconnect all power to unit, making sure that all powerlegs are open.1. DO NOT remove protective terminal cover. Disconnect

the three leads going to the compressor terminals at thenearest point to the compressor.

2. Identify the leads and using a Megger, Hi-PotentialGround Tester, or other suitable instrument which putsout a voltage between 300 and 1500 volts, check for aground separately between each of the three leads andground (such as an unpainted tube on the compressor).

Page 88: Service Manual - R410a - RS6200006R32[1]

SERVICING

88

Do not use a low voltage output instrument such as a volt-ohmmeter.

HI-POT

COMPRESSOR GROUND TEST3. If a ground is indicated, then carefully remove the com-

pressor terminal protective cover and inspect for looseleads or insulation breaks in the lead wires.

4. If no visual problems indicated, carefully remove the leadsat the compressor terminals.

WARNINGDamage can occur to the glass embedded terminals ifthe leads are not properly removed. This can result interminal and hot oil discharging.

Carefully retest for ground, directly between compressorterminals and ground.5. If ground is indicated, replace the compressor.

S-17C UNLOADER TEST PROCEDUREA nominal 24-volt direct current coil activates the internalunloader solenoid. The input control circuit voltage must be18 to 28 volt ac. The coil power requirement is 20 VA. Theexternal electrical connection is made with a molded plugassembly. This plug contains a full wave rectifier to supplydirect current to the unloader coil.

UNLOADER SOLENOID(Molded Plug)

Unloader Test ProcedureIf it is suspected that the unloader is not working, thefollowing methods may be used to verify operation.

1. Operate the system and measure compressor current.Cycle the unloader ON and OFF at 10 second intervals.The compressor amperage should go up or down at least25 percent.

2. If step one does not give the expected results, shut unitoff. Apply 18 to 28 volt ac to the unloader molded plugleads and listen for a click as the solenoid pulls in.Remove power and listen for another click as the unloaderreturns to its original position.

3. If clicks can’t be heard, shut off power and remove thecontrol circuit molded plug from the compressor andmeasure the unloader coil resistance. The resistanceshould be 32 to 60 ohms, depending on compressortemperature.

4. Next check the molded plug.A. Voltage check: Apply control voltage to the plug

wires (18 to 28 volt ac). The measured dc voltageat the female connectors in the plug should bearound 15 to 27 vdc.

B. Resistance check: Measure the resistance fromthe end of one molded plug lead to either of the twofemale connectors in the plug. One of the connec-tors should read close to zero ohms while the othershould read infinity. Repeat with other wire. Thesame female connector as before should read zerowhile the other connector again reads infinity.Reverse polarity on the ohmmeter leads and re-peat. The female connector that read infinity previ-ously should now read close to zero ohms.

C. Replace plug if either of these test methods doesn’tshow the desired results.

S-17D OPERATION TESTIf the voltage, capacitor, overload and motor winding test failto show the cause for failure:

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Remove unit wiring from disconnect switch and wire a testcord to the disconnect switch.

NOTE: The wire size of the test cord must equal the line wiresize and the fuse must be of the proper size and type.2. With the protective terminal cover in place, use the three

leads to the compressor terminals that were discon-nected at the nearest point to the compressor andconnect the common, start and run clips to the respectiveleads.

3. Connect good capacitors of the right MFD and voltagerating into the circuit as shown.

Page 89: Service Manual - R410a - RS6200006R32[1]

SERVICING

89

4. With power ON, close the switch.

WARNINGLine Voltage now present.

A. If the compressor starts and continues to run, the causefor failure is somewhere else in the system.

B. If the compressor fails to start - replace.

COPELAND COMPRESSOR03 A 12345 L

YEAR MONTH SERIALNUMBER

PLANT

S-17E CHECKING 3-PHASE SCROLLCOMPRESSOR ROTATIONVerify the proper rotation of Copeland scroll compressors asfollows:NOTE: The compressor may run backwards (noisy operation)for 1 or 2 seconds at shutdown. This is normal and does notharm the compressor.1. Install gauges and verify that the suction pressure drops

while the discharge pressure increases.2. Listen for normal compressor sound levels. Reverse

rotation results in elevated or unusual sound levels.3. Reverse rotation will result in substantially reduced amp

draw from tabulated values.To correct improper rotation, switch any two power supplyleads at the outdoor unit contactor.

The 3-phase scroll compressors are direction of rotationsensitive. They will rotate in either direction depending on thephasing of the power. There is no negative impact ondurability caused by operating 3-phase compressors inreversed rotation. The compressor's internal protector willtrip, de-energizing the compressor. Continued operation of 3-phase scroll compressors with the rotation reversed willcontribute to compressor failure. All 3-phase scroll compres-sors should be checked for correct phase rotation.

S-18 TESTING CRANKCASE HEATER (OP-TIONAL ITEM)

The crankcase heater must be energized a minimum of four(4) hours before the condensing unit is operated.Crankcase heaters are used to prevent migration or accumu-lation of refrigerant in the compressor crankcase during theoff cycles and prevents liquid slugging or oil pumping on startup.A crankcase heater will not prevent compressor damage dueto a floodback or over charge condition.

WARNINGDisconnect ALL power before servicing.

1. Disconnect the heater lead in wires.2. Using an ohmmeter, check heater continuity - should test

continuous. If not, replace.NOTE: The positive temperature coefficient crankcase heateris a 40 watt 265 voltage heater. The cool resistance of theheater will be approximately 1800 ohms. The resistance willbecome greater as the temperature of the compressor shellincreases.

S-21 CHECKING REVERSING VALVE AND SO-LENOID

Occasionally the reversing valve may stick in the heating orcooling position or in the mid-position.When stuck in the mid-position, part of the discharge gasfrom the compressor is directed back to the suction side,resulting in excessively high suction pressure. An increasein the suction line temperature through the reversing valve canalso be measured. Check operation of the valve by startingthe system and switching the operation from COOLING toHEATING cycle.If the valve fails to change its position, test the voltage (24V)at the valve coil terminals, while the system is on theCOOLING cycle.All heat pumps and ComfortNetTM heat pumps wired inlegacy - If no voltage is registered at the coil terminals, checkthe operation of the thermostat and the continuity of theconnecting wiring from the "O" terminal of the thermostat tothe unit.ComfortNet heat pumps only - Check voltage (24VAC) atthe non-insulated terminal E22 on the UC control board (RVSon silkscreen) and "C" terminal on the 7-pin or 4-pin connec-tor on the UC controlIf voltage is registered at the coil, tap the valve body lightlywhile switching the system from HEATING to COOLING, etc.If this fails to cause the valve to switch positions, remove thecoil connector cap and test the continuity of the reversingvalve solenoid coil. If the coil does not test continuous -replace it.If the coil test continuous and 24 volts is present at the coilterminals, the valve is inoperative - replace it.

S-24 TESTING DEFROST CONTROLLEGACY MODELS:To check the defrost control for proper sequencing, proceedas follows: With power ON; unit not running.1. Jumper defrost thermostat by placing a jumper wire

across the terminals "DFT" and "R"/"R-DFT" at defrostcontrol board.

2. Connect jumper across test pins on defrost control board.3. Set thermostat to call for heating. System should go into

defrost within 21 seconds.

Page 90: Service Manual - R410a - RS6200006R32[1]

SERVICING

90

4. Immediately remove jumper from test pins.5. Using VOM check for voltage across terminals "C & O".

Meter should read 24 volts.6. Using VOM check for voltage across fan terminals DF1

and DF2 on the board. You should read line voltage (208-230 VAC) indicating the relay is open in the defrost mode.

7. Using VOM check for voltage across "W"/"W2" & "C"terminals on the board. You should read 24 volts.

8. If not as above, replace control board.9. Set thermostat to off position and disconnect power

before removing any jumpers or wires.NOTE: Remove jumper across defrost thermostat beforereturning system to service.COMFORTNETTM UNITS:To check the defrost control for proper sequencing, proceedas follows: With power ON; unit not running.1. Set thermostat to call for heating.2. Press TEST and RECALL buttons simultaneously for

approximately 3 seconds, then release them. Systemshould go into defrost immediately.

3. Using VOM check for voltage across terminals "C & O".Meter should read 24 volts (skip this step if system a fullycommunicating system)

4. Visually inspect to see that the frost is gradually meltingon the coil and the compressor is running.

5. Using VOM check for voltage across "W2 & C" terminalson the board. You should read 24 volts.

6. If not as above, replace control board.7. Set thermostat to off position and disconnect power

before removing any jumpers or wires.

S-25 TESTING DEFROST THERMOSTATLEGACY MODELS ONLY:1. Install a thermocouple type temperature test lead on the

tube adjacent to the defrost control. Insulate the leadpoint of contact.

2. Check the temperature at which the control closes itscontacts by lowering the temperature of the control. Part# 0130M00009P which is used on 2 and 2.5 ton unitsshould close at 34°F ± 5°F. Part # 0130M00001P orB1370803 which is used on 3 thru 5 ton units shouldclose at 31°F ± 3°F.

3. Check the temperature at which the control closes itscontacts by lowering the temperature of the control. Part# 0130M00085, which is used onunits with 5 mm coils,should close at 30°F ± 5°F.

4. Check the temperature at which the control opens itscontacts by raising the temperature of the control. Part #0130M00009P which is used on 2 and 2.5 ton unitsshould open at 60°F ± 5°F. Part # 0130M00001P orB1370803 which is used on 3 thru 5 ton units should openat 75°F ± 6°F.

5. Check the temperature at which the control opens itscontacts by raising the temperature of the control. Part #0130M00085, which is used on units with 5 mm coils,should open at 60°F ± 5°F.

6. If not as above, replace control.

S-26 TESTING TEMPERATURE SENSORS(COMFORTNET READY MODELS ONLY)

The ASXC and DSXC ComfortNet ready air conditionermodels are factory equipped with an outdoor air temperature(OAT) sensor. The OAT sensor allows the outdoor airtemperature to be displayed on the CTK0* thermostat whenused with the ASXC and DSXC models.The ASZC and DSZC ComfortNet ready heat pump modelsare equipped with both an outdoor air temperature (OAT)sensor and an outdoor coil temperature (OCT) sensor. TheOAT provides the balance point temperature in heat pumpsystems (air handler w/electric heat + heat pump) and dualfuel systems. The OCT sensor is provides the outdoor coiltemperature and is used in determining defrost cycles.To check either the outdoor air or outdoor coil temperaturesensors:

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Disconnect power to the air conditioner or heat pump.2. Disconnect the sensor from the unitary (UC) control.3. Connect an ohmmeter across the sensor terminals. The

ohmmeter should read be 10kΩ, +/-10%, at 75°F. Re-place the sensor if the sensor is open, shorted, or outsidethe valid resistance range.

S-40 MBR/AR*F ELECTRONIC BLOWER

TIME DELAY RELAYThe MBR/AR*F contains an Electronic Blower Time DelayRelay board, B1370735. This board provides on/off timedelays for the blower motor in cooling and heat pump heatingdemands when “G” is energized.

T, °F RW@T T, °F RW@T T, °F RW@T T, °F RW@T T, °F RW@T-40 336,000 5 72,940 50 19,903 95 6,530 140 2,488-31 242,700 14 55,319 59 15,714 104 5,327 149 2,083-22 177,000 23 42,324 68 12,493 113 4,370 158 1,752-13 130,400 32 32,654 77 10,000 122 3,603 167 1,480-4 97,060 41 25,396 86 8,056 134 2,986 176 1,255

Ohm Reading of Communicating Outdoor Unit Sensors

Page 91: Service Manual - R410a - RS6200006R32[1]

SERVICING

91

During a cooling or heat pump heating demand, 24Vac issupplied to terminal “G” of the EBTDR to turn on the blowermotor. The EBTDR initiates a 7 second delay on and thenenergizes it’s onboard relay. The relay on the EBTDR boardcloses it’s normally open contacts and supplies power to theblower motor. When the “G” input is removed, the EBTDRinitiates a 65 second delay off. When the 65 seconds delayexpires the onboard relay is de-energized and it’s contactsopen and remove power from the blower motor.During an electric heat only demand, “W1” is energized but“G” is not. The blower motor is connected to the normallyclosed contacts of the relay on the EBTDR board. The otherside of this set of contacts is connected to the heat se-quencer on the heater assembly that provides power to thefirst heater element. When “W1” is energized, the sequencerwill close it’s contacts within 10 to 20 seconds to supplypower to the first heater element and to the blower motorthrough the normally closed contacts on the relay on theEBTDR. When the “W1” demand is removed, the sequenceropens it contacts within 30 to 70 seconds and removes powerfrom the heater element and the blower motor.The EBTDR also contains a speedup terminal to reduce thedelays during troubleshooting of the unit. When this terminalis shorted to the common terminal, “C”, on the EBTDR board,the delay ON time is reduced to 3 seconds and the delay OFFtime is reduced to 5 second.Two additional terminals, M1 and M2, are on the EBTDRboard. These terminals are used to connect the unused leadsfrom the blower motor and have no affect on the board’soperation.

S-40A AVPTC/MBVC ELECTRONIC BLOWER/HEATER CONTROL

DescriptionThe AVPTC and MBVC models utilize an electronic controlthat provides ECM blower motor control and control of up totwo electric heat sequencers. The control has thermostatinputs for up to two stages of cooling, two stages of electricheat, reversing valve, and dehumidification. Control input is24VAC.All dipswitches necessary to setup cooling, heat pump, andelectric heat airflow are fully integrated into the control.Dehumidification is enabled/disabled via an on-board dipswitch.FeaturesThe new air handler control includes advanced diagnosticfeatures with fault recall, estimated CFM display via on-boardLED, and ComfortNetTM ready. Diagnostics includes heaterkit selection diagnostics, open fuse, internal control fault,data errors, and blower motor faults. Data errors are notincluded in the fault recall list. Diagnostic error codes aredisplayed on a single red LED.The estimated CFM is displayed on an on-board green LED.The LED flashes once for each 100 CFM.

The AVPTC/MBVC air handlers may be used in a fullycommunicating ComfortNet system when matched with acompatiable outdoor unit and the CTK0* thermostat. A fullycommunicating system offers advanced setup and diagnos-tic features.Basic OperationThe air handler control receives thermostat inputs either froma standard 24VAC thermostat or the CTK0* ComfortNetthermostat. For cooling and heat pump operation, the controloperates the variable speed blower motor at the demand asdetermined from the thermostat input(s). If a demand forelectric heat is received, the control will provide a 24VACoutput for up to two electric heat sequencers.TroubleshootingMotor Control Circuits

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Turn on power to air handler or modular.

WARNINGLine Voltage now present.

2. Check voltage between pins 1 and 4 at the 4-wire motorconnector on the control board. Voltage should bebetween 9 and 15 VDC. Replace control if voltage is notas specified.

Electric Heat Sequencer Outputs

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Turn on power to air handler or modular blower.

WARNINGLine Voltage now present.

2. Disconnect the 4-circuit harness connecting the controlto the electric heater kit.

Page 92: Service Manual - R410a - RS6200006R32[1]

SERVICING

92

3. Provide a thermostat demand for low stage auxiliary heat(W1). Measure the voltage between circuits 1 and 3 at theon-board electric heat connector. Voltage should mea-sure 24VAC. Replace control if no voltage is present.

NOTE: Allow for any built-in time delays before makingvoltage measurements. Any electric heater faults that arepresent may prevent the heater output from energizing.Verify that no heater faults are present before makingvoltage measurements.4. Provide a thermostat demand for high stage auxiliary heat

(W1 + W2). Measure the voltage between circuits 1 and3 at the on-board electric heat connector. Measure thevoltage between circuits 2 and 3 at the on-board electricheat connector. Voltage should measure 24VAC. Re-place control if no voltage is present.

Communications (Applies only to Systems with CompatibleComfortNetTM Outdoor Unit and CTK0*Thermostat)The integrated air handler control has some on-board toolsthat may be used to troubleshoot the network. These toolsare: red communications LED, green receive (Rx) LED, andlearn button. These are described belowa. Red communications LED – Indicates the status of the

network. Refer to the Network Troubleshooting Chart forthe LED status and the corresponding potential problem.

b. Green receive LED – Indicates network traffic. Refer to theNetwork Troubleshooting Chart for the LED status and thecorresponding potential problem.

c. Learn button – Used to reset the network. Depress thebutton for approximately 2 seconds to reset the network.

Voltages between the two data lines and between each dataline and common may be used to determine if the networkis operating properly.Do the following to measure the voltages on the communi-cations data lines.

WARNINGLine Voltage now present.

1. With power on to the unit, measure voltage betweenterminal "1" and terminal "C" on control board's thermo-stat connector. Voltage should be as noted in the tablebelow.

2. Measure voltage between terminals "2" and "C".3. Measure voltage between terminals "1" and "2".4. If voltages are different than stated in the table below,

check thermostat wiring for opens/shorts. Confirm thatthe BIAS and TERM dipswitches are in the ON position.

5. The network troubleshooting chart on the next pageprovides additonal communications troubleshooting in-formation.

Terminals Nonimal dc Voltages

1 to C > 2.5 Vdc2 to C < 2.5 Vdc1 to 2 > 0.2 Vdc

Page 93: Service Manual - R410a - RS6200006R32[1]

SERVICING

93

L E D L E D S t a tu s In d ic a ti o n P os s i b le C a u s e s

C o rr e c ti v e Ac t io n (s )

N o te s & C a ut io n s

O ff • N o r m a l c o n d i t io n

• N o n e • N o n e • N o n e

• D e p r e s s o n ce q u ic k ly fo r a p o w e r -u p r e s e t• D e p r e s s a n d h o l d fo r 2s e c o n d s fo r a n o u t-o f -b o x r e s e t

• C o n tr o l p o w e r u p

• L e a r n b u tto n d e p r e s s e d

• N o p o w e r • N o p o w e r to m o d u l a r b lo w e r

• C h e c k fu se s a n d c i r cu it b r e a k e rs ; r e p l a c e /r e se t

• C o m m u n ic a t io n e rr o r

• O p e n fu se • R e p la c e b l o w n f u s e

• C o m m u n i c a t i o n e r r o r

• C h e c k fo r sh o r ts i n lo w vo lta g e w i r in g i n m o d u l a r b lo w e r /s ys te m

• R e s e t n e tw o r k b y d e p re ss i n g le a r n b u tt o n• C h e ck d a ta 1 / d a ta 2 vo lta g e s

• B r o ke n / d i sc o n n e c t e d d a ta w ir e (s )

• C h e c k c o m m u n i c a t i o n s w i r in g ( d a ta 1 / d a ta 2 w i re s)

• T u r n p o w e r O F F p r i o r to r e p a ir

• M o d u l a r b lo w e r is in s t a l le d a s a le g a c y / t r a d it io n a l s ys te m

• C h e c k w i r e c o n n e ct io n s a t t e r m i n a l b lo ck

• V e r if y w i r e s a t te rm in a l b l o c k s a r e s e c u r e l y tw i s t e d to g e th e r p ri o r to i n s e r t i n g in to te rm in a l b l o c k

• V e r i fy m o d u l a r b lo w e r i n s ta l la t i o n t yp e ( le g a cy / t ra d i t io n a l o r c o m m u n i c a t i n g )

• C h e c k d a ta 1 / d a ta 2 v o l ta g e s

R a p id F la s h i n g • N o r m a l n e tw o rk t r a f f ic

• C o n tr o l is “ ta l k i n g ” o n n e tw o r k a s e x p e c te d

• N o n e • N o n e

• D a t a 1 a n d d a ta 2 w ir e s r e ve rs e d a t m o d u l a r b lo w e r th e rm o s ta t, o r C T ™ c o m p a ti b le o u td o o r A C /H P

• C h e c k c o m m u n i c a t i o n s w i r in g ( d a ta 1 / d a ta 2 w i re s)

• T u rn p o w e r O F F p r i o r to r e p a ir

• S h o r t b e tw e e n d a ta 1 a n d d a ta 2 w ir e s

• C h e c k w i r e c o n n e ct io n s a t t e r m i n a l b lo ck

• V e r if y w i r e s a t te rm in a l b l o c k s a r e s e c u r e l y tw i s t e d to g e th e r p ri o r to i n s e r t i n g in to te rm in a l b l o c k

• S h o r t b e tw e e n d a ta 1 o r d a ta 2 w ir e s a n d R ( 2 4 V A C ) o r C ( 2 4 V A C c o m m o n )

• C h e c k d a ta 1 / d a ta 2 v o l ta g e s

• N o n e

G r e e n R e c e i ve L E D

O ff • T u r n p o w e r O F F p r i o r to r e p a ir

1 S te a d y F l a s h • N o n e tw o r k fo u n d

O n S o l i d • D a ta 1 / D a ta 2 m is s - w ir e

R e d C o m m u n i ca t i o n s

L E D

• D e p r e ss L e a r n B u t to n

2 F la sh e s • O u t -o f- b o x r e s e t • N o n e

1 F la s h • C o m m u n ic a t io n F a i l u r e

• C o m m u n i c a t i o n F a i lu re

NETWORK TROUBLESHOOTING CHART

Page 94: Service Manual - R410a - RS6200006R32[1]

SERVICING

94

SEQUENCE OF OPERATIONThis document covers the basic sequence of operation for atypical application with a mercury bulb thermostat. When adigital/electronic thermostat is used, the on/off staging of theauxiliary heat will vary. Refer to the installation instruc-tions and wiring diagrams provided with the MBR/AR*Ffor specific wiring connections and system configura-tion.MBR/AR*F WITH SINGLE STAGE CONDENSERS1.0 Cooling Operation1.1 On a demand for cooling, the room thermostat energizes

“G” and “Y” and 24Vac is supplied to “Y” at the condens-ing unit and the “G” terminal on the EBTDR board.

1.2 The compressor and condenser fan are turned on andafter a 7 second on delay, the relay on the EBTDR boardis energized and the blower motor starts.

1.3 When the cooling demand “Y” is satisfied, the roomthermostat removes the 24Vac from “G” and “Y”.

1.4 The compressor and condenser fan are turned off andafter a 65 second delay off, the relay on the EBTDR boardis de-energized and the blower is turned off.

2.0 Heating Operation2.1 On a demand for heat, the room thermostat energizes

“W1” and 24Vac is supplied to heat sequencer, HR1, onthe heater assembly.

2.2 The contacts M1 and M2 will close within 10 to 20seconds and turn on heater element #1. The normallyclosed contacts on the EBTDR are also connected toterminal M1. When M1 and M2 close, the blower motorwill be energized thru the normally closed contacts onthe EBTDR board. At the same time, if the heaterassembly contains a second heater element, HR1 willcontain a second set of contacts, M3 and M4, which willclose to turn on heater element #2.

Note: If more than two heater elements are on the heaterassembly, it will contain a second heat sequencer, HR2,whichwill control the 3rd and 4th heater elements if available. If thefirst stage heat demand, “W1” cannot be satisfied by the heatpump, the temperature indoors will continue to drop. Theroom thermostat will then energize “W2” and 24Vac will besupplied to HR2 on the heater assembly. When the “W2”demand is satisfied, the room thermostat will remove the24Vac from HR2. The contacts on HR2 will open between 30to 70 seconds and heater elements #3 and #4 will be turnedoff. On most digital/electronic thermostats, “W2” willremain energized until the first stage demand “W1” issatisfied and then the “W1” and “W2” demands will beremoved.2.3 When the “W1” heat demand is satisfied, the room

thermostat will remove the 24Vac from HR1. Both set ofcontacts on the relay opens within 30 to 70 seconds andturn off the heater element(s) and the blower motor.

MBR/AR*F WITH SINGLE STAGE HEAT PUMPS3.0 Cooling OperationOn heat pump units, when the room thermostat set to thecooling mode, 24Vac is supplied to “O” which energizes thereversing valve. As long as the thermostat is set for cooling,the reversing valve will be in the energized position for cooling.3.1 On a demand for cooling, the room thermostat energizes

“G” and “Y” and 24Vac is supplied to “Y” at the heat pumpand the “G” terminal on the EBTDR board.

3.2 The heat pump turned on in the cooling mode and aftera 7 second on delay, the relay on the EBTDR board isenergized and the blower motor starts.

3.3 When the cooling demand is satisfied, the room thermo-stat removes the 24Vac from “G” and “Y”.

3.4 The heat pump is turned off and after a 65 second delayoff, the relay on the EBTDR board is de-energized and theblower motor is turned off.

4.0 Heating OperationOn heat pump units, when the room thermostat set to theheating mode, the reversing valve is not energized. As longas the thermostat is set for heating, the reversing valve will bein the de-energized position for heating except during adefrost cycle. Some installations may use one or moreoutdoor thermostats to restrict the amount of electric heatthat is available above a preset ambient temperature. Use ofoptional controls such as these can change the operation ofthe electric heaters during the heating mode. This sequenceofoperation does not cover those applications.4.1 On a demand for first stage heat with heat pump units,

the room thermostat energizes “G” and “Y” and 24Vac issupplied to “Y” at the heat pump unit and the “G” terminalon the EBTDR board. The heat pump is turned on in theheating mode and the blower motor starts after a 7second on delay.

4.2 If the first stage heat demand cannot be satisfied by theheat pump, the temperature indoors will continue to drop.The room thermostat will then energize terminal “W2’ forsecond stage heat and 24Vac will be supplied to heatsequencer HR1 on the heater assembly.

4.3 HR1 contacts M1 and M2 will close will close within 10to 20 seconds and turn on heater element #1. At thesame time, if the heater assembly contains a secondheater element, HR1 will contain a second set of con-tacts, M3 and M4, which will close and turn on heaterelement #2. The blower motor is already on as a resultof terminal “G” on the EBTDR board being energized forthe first stage heat demand.

Note: If more than two heater elements are on the heaterassembly, it will contain a second heat sequencer, HR2,which will control the 3rd and 4th heater elements if available.If the second stage heat demand, “W2” cannot be satisfied bythe heat pump, the temperature indoors will continue to drop.The room thermostat will then energize “W3” and 24Vac willbe supplied to HR2 on the heater assembly. When the “W3”demand is satisfied, the room thermostat will remove the

Page 95: Service Manual - R410a - RS6200006R32[1]

SERVICING

95

24Vac from HR2. The contacts on HR2 will open between 30to 70 seconds and heater elements #3 and #4 will be turnedoff. On most digital/electronic thermostats, “W3” willremain energized until the first stage heat demand “Y”is satisfied and then the “G”, “Y”, “W2” and “W3”demands will be removed.4.4 As the temperature indoors increase, it will reach a point

where the second stage heat demand, “W2”, is satisfied.When this happens, the room thermostat will remove the24Vac from the coil of HR1. The contacts on HR1 willopen between 30 to 70 seconds and turn off both heaterelement(s). The heat pump remains on along with theblower motor because the “Y” demand for first stage heatwill still be present.

4.5 When the first stage heat demand “Y” is satisfied, theroom thermostat will remove the 24Vac from “G” and “Y”.The heat pump is turned off and the blower motor turns offafter a 65 second off delay.

5.0 Defrost OperationOn heat pump units, when the room thermostat is set to theheating mode, the reversing valve is not energized. As longas the thermostat is set for heating, the reversing valve will bein the de-energized position for heating except during adefrost cycle.5.1 The heat pump will be on and operating in the heating

mode as described the Heating Operation in section 4. 5.2 The defrost control in the heat pump unit checks to seeif

a defrost is needed every 30, 60 or 90 minutes of heatpump operation depending on the selectable setting bymonitoring the state of the defrost thermostat attached tothe outdoor coil.

5.3 If the temperature of the outdoor coil is low enough tocause the defrost thermostat to be closed when thedefrost board checks it, the board will initiate a defrostcycle.

5.4 When a defrost cycle is initiated, the contacts of theHVDR relay on the defrost board open and turns off theoutdoor fan. The contacts of the LVDR relay on thedefrost board closes and supplies 24Vac to “O” and“W2”. The reversing valve is energized and the contactsonHR1 close and turns on the electric heater(s). The unitwill continue to run in this mode until the defrost cycle iscompleted.a.For models with defrost control PCBDM133 or

PCBDM160, a 30 second compressor delay at defrostinitiation/termination is optional. As shipped from thefactory, the control is set for the delay (“DLY”), whichwill turn the compressor off for 30 seconds while thereversing valve shifts to/from the cooling mode posi-tion. To bypass the delay, which typically reducessound levels during defrost mode, change the pinsettings from “DLY” to “NORM”.

5.5 When the temperature of the outdoor coil rises highenough to causes the defrost thermostat to open, thedefrost cycle will be terminated. If at the end of theprogrammed 10 minute override time the defrost thermo-stat is still closed, the defrost board will automaticallyterminate the defrost cycle.

5.6 When the defrost cycle is terminated, the contacts of theHVDR relay will close to start the outdoor fan and thecontacts of the LVDR relay will open and turn off thereversing valve and electric heater(s). The unit will nowbe back in a normal heating mode with a heat pumpdemand for heating as described in the Heating Opera-tion in section 4. See section 5.4a.

MBE/AEPF WITH GSX, SSX, ASX, DSX, VSX

MBE ELECTRONIC BLOWER TIME DELAY RELAYAEPF AIR HANDLER

SEQUENCE OF OPERATIONThis document covers the basic sequence of operation for atypical application with a mercury bulb thermostat. When adigital/electronic thermostat is used, the on/off staging of theauxiliary heat will vary. Refer to the installation instruc-tions and wiring diagrams provided with the MBE/AEPFfor specific wiring connections, dip switch settings andsystem configuration.MBE/AEPF WITH SINGLE STAGE GSX, ASX, SSX, andVSX CONDENSERSWhen used with a single stage GSX, SSX, ASX, and VSXcondensers, dip switch #4 must be set to the on position onthe VSTB inside the MBE/AEPF. The “Y” output from theindoor thermostat must be connected to the yellow wirelabeled “Y/Y2” inside the wire bundle marked “Thermostat”and the yellow wire labeled “Y/Y2” inside the wire bundlemarked “Outdoor Unit” must be connected to “Y” at thecondenser. The orange jumper wire from terminal “Y1”to terminal“O” on the VSTB inside the MBE/AEPF mustremain connected.1.0 Cooling Operation1.1 On a demand for cooling, the room thermostat energizes“G” and “Y” and 24Vac is supplied to “G” and “Y/Y2” of theMBE/AEPF unit. The VSTB inside the MBE/AEPF willturnon the blower motor and the motor will ramp up to thespeed programmed in the motor based on the settings for dipswitch 5 and 6. The VSTB will supply 24Vac to “Y” at thecondenser and the compressor and condenser are turned on.1.2 When the cooling demand is satisfied, the room thermo-

stat removes the 24Vac from “G” and “Y”. The MBE/AEPF removes the 24Vac from “Y’ at the condenser andthe compressor and condenser fan are turned off. Theblower motor will ramp down to a complete stop based onthe time and rate programmed in the motor.

2.0 Heating Operation2.1 On a demand for heat, the room thermostat energizes

“W1” and 24Vac is supplied to terminal “E/W1” of theVSTB inside the MBE/AEPF unit. The VSTB will turn onthe blower motor and the motor will ramp up to the speedprogrammed in the motor based on the settings for dipswitch 1 and 2. The VSTB will supply 24Vac to heatsequencer HR1 on the electric heater assembly.

Page 96: Service Manual - R410a - RS6200006R32[1]

SERVICING

96

2.2 HR1 contacts M1 and M2 will close within 10 to 20seconds and turn on heater element #1. At the sametime, if the heater assembly contains a second heaterelement, HR1 will contain a second set of contacts, M3and M4, which will close and turn on heater element #2.

Note: If more than two heater elements are on the heaterassembly, it will contain a second heat sequencer, HR2,which will control the 3rd and 4th heater elements if available.For the 3rd and 4th heater elements to operate on asecond stage heat demand, the PJ4 jumper on theVSTB inside the MBE/AEPF must be cut. With the PJ4jumper cut, the VSTB will run the blower motor on lowspeed on a “W1” only demand. If the first stage heatdemand, “W1” cannot be satisfied by the heat pump, thetemperature indoors will continue to drop. The roomthermostat will then energize “W2” and 24Vac will besupplied to HR2 on the heater assembly and the blowermotor will change to high speed. When the “W2” demandis satisfied, the room thermostat will remove the 24Vacfrom “W2” and the VSTB will remove the 24Vac from HR2.The contacts on HR2 will open between 30 to 70 secondsand heater elements #3 and #4 will be turned off and theblower motor will change to low speed. On most digital/electronic thermostats, “W2” will remain energizeduntil the first stage demand “W1” is satisfied and thenthe “W1” and “W2” demands will be removed.2.3 When the “W1” heat demand is satisfied, the room

thermostat will remove the 24Vac from “E/W1” and theVSTB removes the 24Vac from HR1. The contacts onHR1 will open between 30 to 70 seconds and turn offthe heater element(s) and the blower motor rampsdown to a complete stop.

MBE/AEPF WITH SINGLE STAGEGSZ, SSZ, ASZ, and VSZ HEAT PUMPS

When used with a single stage GSZ, SSZ, ASZ, or VSZheat pumps, dip switch #4 must be set to the ON positionon the VSTB inside the MBE. The “Y” output from theindoor thermostat must be connected to the yellow wirelabeled “Y/Y2” inside the wire bundle marked “Thermostat”and the yellow wire labeled “Y/Y2” inside the wire bundlemarked “Outdoor Unit” must be connected to “Y” at the heatpump. The orange jumper wire from terminal “Y1” toterminal “O” on the VSTB inside the MBE/AEPF mustbe removed.

3.0 COOLING OPERATIONOn heat pump units, when the room thermostat is set to thecooling mode, 24Vac is supplied to terminal “O” of theVSTB inside the MBE/AEPF unit. The VSTB will supply24Vac to “O” at the heat pump to energize the reversingvalve. As long as the thermostat is set for cooling, thereversing valve will be in the energized position for cooling.3.1 On a demand for cooling, the room thermostat ener-

gizes “G” and “Y” and 24Vac is supplied to terminals“G” and “Y/Y2” of the MBE/AEPF unit. The VSTB willturn on the blower motor and the motor will ramp up to

the speed programmed in the motor based on thesettings of dip switch 5 and 6. The VSTB will supply24Vac to “Y” at the heat pump.

3.2 The heat pump is turned on in the cooling mode.3.3 When the cooling demand is satisfied, the room thermo-

stat removes the 24Vac from “G” and “Y/Y2” of the MBE/AEPF and the VSTB removes the 24Vac from “Y” at theheat pump. The heat pump is turned off and the blowermotor will ramp down to a complete stop based on thetime and rate programmed in the motor.

4.0 Heating OperationOn heat pump units, when the room thermostat is set tothe heating mode, the reversing valve is not energized.As long as the thermostat is set for heating, the reversingvalve will be in the de-energized position for heatingexcept during a defrost cycle. Some installations mayuse one or more outdoor thermostats to restrict theamount of electric heat that is available above a presetambient temperature. Use of optional controls such asthese can change the operation of the electric heatersduring the heating mode. This sequence of operationdoes not cover those applications.

4.1 On a demand for first stage heat with heat pump units,the room thermostat energizes “Y” and “G” and 24Vac issupplied to “G” and “Y/Y2” of the MBE/AEPF. The VSTBwill turn on the blower motor and the motor will ramp upto the speed programmed in the motor based on thesettings of dip switch 1 and 2. The VSTB will supply24Vac to “Y” at the heat pump and the heat pump isturned on in the heating mode.

4.2 If the first stage heat demand cannot be satisfied by theheat pump, the temperature indoors will continue to drop.The room thermostat will then energize terminal “W2” forsecond stage heat and 24Vac will be supplied to “E/W1”of the MBE/AEPF. The VSTB will supply 24Vac to heatsequencer, HR1, on the electric heater assembly.

4.3 HR1 contacts M1 and M2 will close within 10 to 20seconds and turn on heater element #1. At the sametime, if the heater assembly contains a second heaterelement, HR1 will contain a second set of contacts, M3and M4, which will close to turn on heater element #2.

Note: If more than two heater elements are on the heaterassembly, it will contain a second heat sequencer, HR2,which will control the 3rd and 4th heater elements if available.For the 3rd and 4th heater elements to operate on a thirdstage heat demand, the PJ4 jumper on the VSTB insidethe MBE/AEPF must be cut. If the second stage heatdemand, “W2”, cannot be satisfied by the heat pump, thetemperature indoors will continue to drop. The room thermo-stat will then energize “W3” and 24Vac will be supplied to “W/W2” of the MBE/AEPF. The VSTB will supply 24Vac to HR2on the electric heater assembly. When the “W3” demand issatisfied, the room thermostat will remove the 24Vac from“W/W2” of the MBE/AEPF. The contacts on HR2 will openbetween 30 to 70 seconds and heater elements #3 and #4 will

Page 97: Service Manual - R410a - RS6200006R32[1]

SERVICING

97

be turned off. On most digital/electronic thermostats,“W3” will remain energized until the first stage de-mand “Y” is satisfied and then the “G”, “Y”, “W2” and“W3” demands will be removed.4.4 As the temperature indoors increase, it will reach a point

where the second stage heat demand, “W2”, is satisfied.When this happens, the room thermostat will remove the24Vac from “E/W1” of the MBE/AEPF. The contacts onHR1 will open between 30 to 70 seconds and turn off bothheater element(s). The heat pump remains on along withthe blower motor because the “Y” demand for first stageheat will still be present.

4.5 When the first stage heat demand “Y” is satisfied, theroom thermostat will remove the 24Vac from “G” and “Y/Y2” of the MBE/AEPF. The VSTB removes the 24Vacfrom “Y” at the heat pump and the heat pump is turned off.The blower motor will ramp down to a complete stopbased on the time and rate programmed in the motorcontrol.

5.0 DEFROST OPERATIONOn heat pump units, when the room thermostat is set to theheating mode, the reversing valve is not energized. As longas the thermostat is set for heating, the reversing valve will bein the de-energized position for heating except during adefrost cycle.5.1 The heat pump will be on and operating in the heating

mode as described the Heating Operation in section 4.5.2 The defrost control in the heat pump unit checks to see

if a defrost is needed every 30, 60 or 90 minutes of heatpump operation depending on the selectable setting bymonitoring the state of the defrost thermostat attached tothe outdoor coil.

5.3 If the temperature of the outdoor coil is low enough tocause the defrost thermostat to be closed when thedefrost board checks it, the board will initiate a defrostcycle.

5.4 When a defrost cycle is initiated, the contacts of theHVDR relay on the defrost board open and turns off theoutdoor fan. The contacts of the LVDR relay on thedefrost board closes and supplies 24Vac to “O” and“W2”. The reversing valve is energized and the contactson HR1 close and turns on the electric heater(s). The unitwill continue to run in this mode until the defrost cycle iscompleted.

a. For models with defrost control PCBDM133 orPCBDM160, a 30 second compressor delay at defrostinitiation/termination is optional. As shipped from thefactory, the control is set for the delay (“DLY”), whichwill turn the compressor off for 30 seconds while thereversing valve shifts to/from the cooling mode posi-tion. To bypass the delay, which typically reducessound levels during defrost mode, change the pinsettings from “DLY” to “NORM”.

5.5 When the temperature of the outdoor coil rises highenough to causes the defrost thermostat to open, thedefrost cycle will be terminated. If at the end of theprogrammed 10 minute override time the defrost thermo-stat is still closed, the defrost board will automaticallyterminate the defrost cycle.

5.6 When the defrost cycle is terminated, the contacts of theHVDR relay on the defrost board will close to start theoutdoor fan and the contacts of the LVDR relay will openand turn off the reversing valve and electric heater(s). Theunit will now be back in a normal heating mode with a heatpump demand for heating as described in the HeatingOperation in section 4. See section 5.4a.

SEQUENCE OF OPERATIONThis document covers the basic sequence of operation for atypical application with a mercury bulb thermostat. When adigital/electronic thermostat is used, the on/off staging of theoutdoor unit and auxiliary heat will vary. Refer to theinstallation instructions and wiring diagrams provided with theMBE for specific wiring connections, dip switch settings andsystem configuration.MBE/AEPF WITH TWO STAGE ASX & DSX CONDENS-ERS

1.0 COOLING OPERATIONWhen used with the ASX & DSX two stage condens-ers, dip switch #4 must be set to the OFF position onthe VSTB inside the MBE/AEPF. The “Y1” outputfrom the indoor thermostat must be connected to thepurple wire labeled “Ylow/Y1” inside the wire bundlemarked “Thermostat” and the purple wire labeled “Ylow/Y1” inside the wire bundle marked “Outdoor Unit” must beconnected to “Ylow/Y1” at the condenser. The “Y2”output from the indoor thermostat must be connected tothe yellow wire labeled “Y/Y2” inside the wire bundlemarked “Thermostat” and the yellow wire labeled “Y/Y2”inside the wire bundle marked “Outdoor Unit” must beconnected to “Y/Y2” at the condenser. The orangejumper wire from terminal “Y1” to terminal “O” onthe VSTB inside the MBE/AEPF must remain con-nected.

1.1 On a demand for cooling, the room thermostat energizes“G” and “Y1” and 24Vac is supplied to “G” and “Ylow/Y1”of the MBE/AEPF unit. The VSTB inside the MBE/AEPFwill turn on the blower motor and the motor will ramp upto 60% of the speed programmed in the motor based onthe settings for dip switch 5 and 6. The VSTB will supply24Vac to “Ylow/Y1” at the condenser and the compres-sor and condenser fan starts in low speed operation.

1.2 If first stage cooling cannot satisfy the demand, the roomthermostat will energize “Y2” and supply 24Vac to theMBE/AEPF unit. The blower motor will change to the cfmfor high speed operation and the VSTB will supply 24Vacto “Y/Y2” at the condenser and the compressor andcondenser fan will change to high speed operation.When the “Y2” demand is satisfied, the thermostat willremove the “Y2” demand and the VSTB will remove the

Page 98: Service Manual - R410a - RS6200006R32[1]

SERVICING

98

24Vac from “Y/Y2” at the condenser. The blower will dropto 60% of the programmed cfm and the compressor andcondenser fan will change to low speed. On mostdigital/electronic thermostats, “Y2” will remain en-ergized until the first stage cooling demand “Y1” issatisfied and then the “G”, “Y1” and “Y2” demandswill be removed.

1.3 When the first stage cooling demand, “Y1”, is satisfied,the room thermostat removes the 24Vac from “G” and“Y1”. The MBE/AEPF removes the 24Vac from “Ylow/Y1’ at the condenser and the compressor and condenserfan are turned off. The blower motor will ramp down to acomplete stop based on the time and rate programmedin the motor.

2.0 Heating Operation2.1 On a demand for heat, the room thermostat energizes

“W1” and 24Vac is supplied to terminal “E/W1” of theVSTB inside the MBE/AEPF unit. The VSTB will turn onthe blower motor and the motor will ramp up to the speedprogrammed in the motor based on the settings for dipswitch 1 and 2. The VSTB will supply 24Vac to heatsequencer HR1 on the electric heater assembly.

2.2 HR1 contacts M1 and M2 will close within 10 to 20seconds and turn on heater element #1. At the sametime, if the heater assembly contains a second heaterelement, HR1 will contain a second set of contacts, M3and M4, which will close and turn on heater element #2.

Note: If more than two heater elements are on the heaterassembly, it will contain a second heat sequencer, HR2,which will control the 3rd and 4th heater elements if available.For the 3rd and 4th heater elements to operate on asecond stage heat demand, the PJ4 jumper on theVSTB inside the MBE/AEPF must be cut. With the PJ4jumper cut, the VSTB will run the blower motor on low speedon a “W1” only demand. If the first stage heat demand, “W1”cannot be satisfied by the heat pump, the temperatureindoors will continue to drop. The room thermostat will thenenergize “W2” and 24Vac will be supplied to HR2 on theheater assembly and the blower motor will change to highspeed. When the “W2” demand is satisfied, the roomthermostat will remove the 24Vac from “W2” and the VSTBwill remove the 24Vac from HR2. The contacts on HR2 willopen between 30 to 70 seconds and heater elements #3 and#4 will be turned off and the blower motor will change to lowspeed. On most digital/electronic thermostats, “W2”will remain energized until the first stage demand“W1” is satisfied and then the “W1” and “W2” demandswill be removed.2.3 When the “W1” heat demand is satisfied, the room

thermostat will remove the 24Vac from “E/W1” and theVSTB removes the 24Vac from HR1. The contacts onHR1 will open between 30 to 70 seconds and turn off theheater element(s) and the blower motor ramps down to acomplete stop.

MBE/AEPF WITH TWO STAGE ASZ & DSZ HEAT PUMPUNITS

3.0 Cooling OperationWhen used with the ASZ & DSZ two stage heatpumps, dip switch #4 must be set to the OFF positionon the VSTB inside the MBE/AEPF. The “Y1” outputfrom the indoor thermostat must be connected to thepurple wire labeled “Ylow/Y1” inside the wire bundlemarked “Thermostat” and the purple wire labeled “Ylow/Y1” inside the wire bundle marked “Outdoor Unit” must beconnected to “Y” at the heat pump. The “Y2” output fromthe indoor thermostat must be connected to the yellowwire labeled “Y/Y2” inside the wire bundle marked “Ther-mostat” and the yellow wire labeled “Y/Y2” inside the wirebundle marked “Outdoor Unit” must be connected to “Y/Y2” at the heat pump. The orange jumper wire fromterminal “Y1” to terminal “O” on the VSTB insidethe MBE/AEPF must be removed.On heat pump units, when the room thermostat is set tothe cooling mode, 24Vac is supplied to terminal “O” of theVSTB inside the MBE unit. The VSTB will supply 24Vacto “O” at the heat pump to energize the reversing valve.As long as the thermostat is set for cooling, the reversingvalve will be in the energized position for cooling.

3.1 On a demand for cooling, the room thermostat energizes“G” and “Y1” and 24Vac is supplied to “G” and “Ylow/Y1”of the MBE unit. The VSTB inside the MBE will turn onthe blower motor and the motor will ramp up to 60% of thespeed programmed in the motor based on the settings fordip switch 5 and 6. The VSTB will supply 24Vac to “Y”at the heat pump and the compressor and outdoor fanstarts in low speed operation.

3.2 If first stage cooling cannot satisfy the demand, the roomthermostat will energize “Y2” and supply 24Vac to “Y/Y2”of the MBE unit. The blower motor will change to thecfm for high speed operation and the VSTB will supply24Vac to “Y2” at the heat pump. The compressor andoutdoor fan will change to high speed operation. Whenthe “Y2” demand is satisfied, the thermostat will removethe “Y2” demand and the VSTB will remove the 24Vacfrom “Y2” at the heat pump. The blower will drop to 60%of the programmed cfm and the compressor and outdoorfan will change to low speed operation. On most digital/electronic thermostats, “Y2” will remain energizeduntil the first stage cooling demand “Y1” is satisfiedand then the “G”, “Y1” and “Y2” demands will beremoved.

3.3 When the first stage cooling demand, “Y1”, is satisfied,the room thermostat removes the 24Vac from “G” and“Y1”. The VSTB removes the 24Vac from “Y’ at the heatpump and the compressor and outdoor fan are turned off.The blower motor will ramp down to a complete stopbased on the time and rate programmed in the motor.

Page 99: Service Manual - R410a - RS6200006R32[1]

SERVICING

99

4.0 Heating OperationOn heat pump units, when the room thermostat is set tothe heating mode, the reversing valve is not energized.As long as the thermostat is set for heating, the reversingvalve will be in the de-energized position for heatingexcept during a defrost cycle. Some installations mayuse one or more outdoor thermostats to restrict theamount of electric heat that is available above a presetambient temperature. Use of optional controls such asthese can change the operation of the electric heatersduring the heating mode. This sequence of operationdoes not cover those applications.

4.1 On a demand for first stage heat with heat pump units, theroom thermostat energizes “G” and “Y1” and 24Vac issupplied to “G” and “Ylo/Y1” of the MBE/AEPF. TheVSTB will turn on the blower motor and the motor willramp up to 60% of the speed programmed in the motorbased on the settings of dip switch 1 and 2. The VSTBwill supply 24Vac to “Y” at the heat pump. The com-pressor will start on low stage and outdoor fan willstart on low speed on a “Y1” heating demand butthe blower motor will deliver only 60% of the pro-grammed cfm for high speed heating operation.

4.2 If a thermostat that provides a “Y2” demand in heating isused and first stage heating cannot satisfy the demand,the room thermostat will energize “Y2” and supply 24Vacto “Y/Y2” of the MBE unit. The blower motor will changeto the cfm for high speed heating operation and the VSTBwill supply 24Vac to “Y/Y2” at the heat pump. Theoutdoor fan will change to high speed operation andcompressor will shift to high stage. If the “Y2” demandis present and becomes satisfied, the thermostat willremove the “Y2” demand and the VSTB will remove the24Vac from “Y/Y2” at the heat pump. The blower will dropto 60% of the programmed cfm and the outdoor fan willchange to low speed. On most digital/electronic thermo-stats, “Y2” will remain energized until the first stageheating demand “Y1” is satisfied and then the “G”, “Y1”and “Y2” demands will be removed.

4.3 If the heat pump operation cannot satisfy the demand, theroom thermostat energizes “W2/W3” and 24Vac is sup-plied to terminal “E/W1” of the VSTB inside the MBE/AEPF unit. The VSTB will supply 24Vac to heatsequencer HR1 on the electric heater assembly.

4.4 HR1 contacts M1 and M2 will close within 10 to 20seconds and turn on heater element #1. At the sametime, if the heater assembly contains a second heaterelement, HR1 will contain a second set of contacts,M3and M4, which will close and turn on heater element#2.

Note: If more than two heater elements are on the heaterassembly, it will contain a second heat sequencer, HR2,which will control the 3rd and 4th heater elements if available.For the 3rd and 4th heater elements to operate on asecond stage auxiliary heat demand, the PJ4 jumper onthe VSTB inside the MBE/AEPF must be cut. If the “W2/W3” demand cannot be satisfied by the heat pump, the

temperature indoors will continue to drop. The room thermo-stat will then energize “W3/W4” and 24Vac will be suppliedto “W/W2” of the MBE. The VSTB will supply 24Vac to HR2on the electric heater assembly. When the “W3/W4” demandis satisfied, the room thermostat will remove the 24Vac from“W/W2” of the MBE/AEPF. The contacts on HR2 will openbetween 30 to 70 seconds and heater elements #3 and #4 willbe turned off. On most digital/electronic thermostats,“W3/W4” will remain energized until the first stagedemand “Y1” is satisfied and then the “G”, “Y1”, “Y2”“W2/W3” and “W3/W4” demands will be removed.4.5 As the temperature indoors increase, it will reach a point

where the “W2/W3” demand is satisfied. When thishappens, the room thermostat will remove the 24Vacfrom “E/W1” of the MBE/AEPF. The contacts on HR1 willopen between 30 to 70 seconds and turn off the 1st and2nd heater elements. If the “Y2” demand is present andbecomes satisfied the room thermostat will remove the24Vac from “Y/Y2” of the MBE and the blower motor willchange to 60% of the programmed cfm. The VSTB willremove the 24Vac from “Y/Y2” at the heat pump and theoutdoor fan will change to low speed operation. The heatpump remains on along with the blower motor becausethe “Y1” demand for first stage heat will still be present.

4.6 When the first stage heat demand “Y1” is satisfied, theroom thermostat will remove the 24Vac from “G” and “Ylo/Y1” of the MBE/AEPF. The VSTB removes the 24Vacfrom “Ylo/Y1” at the heat pump and the compressor andoutdoor fan are turned off. The blower motor will rampdown to a complete stop based on the time and rateprogrammed in the motor control.

5.0 Defrost OperationOn heat pump units, when the room thermostat is set tothe heating mode, the reversing valve is not energized.As long as the thermostat is set for heating, the reversingvalve will be in the de-energized position for heatingexcept during a defrost cycle.

5.1 The heat pump will be on and operating in the heatingmode as described the Heating Operation in section 4.

5.2 The defrost control in the heat pump unit checks to seeif a defrost is needed every 30, 60 or 90 minutes of heatpump operation depending on the selectable setting bymonitoring the state of the defrost thermostat attached tothe outdoor coil.

5.3 If the temperature of the outdoor coil is low enough tocause the defrost thermostat to be closed when thedefrost board checks it, the board will initiate a defrostcycle.

5.4 When a defrost cycle is initiated, the contacts oftheHVDR relay on the defrost board open and turns off theoutdoor fan. The contacts of the LVDR relay on thedefrost board closes and supplies 24Vac to “O” and“W2”. The reversing valve is energized and the contactson HR1 close and turns on the electric heater(s). The unitwill continue to run in this mode until the defrost cycle iscompleted.

Page 100: Service Manual - R410a - RS6200006R32[1]

SERVICING

100

a. For models with defrost control PCBDM133 orPCBDM160, a 30 second compressor delay at defrostinitiation/termination is optional. As shipped from thefactory, the control is set for the delay (“DLY”), whichwill turn the compressor off for 30 seconds while thereversing valve shifts to/from the cooling mode position.To bypass the delay, which typically reduces soundlevels during defrost mode, change the pin settingsfrom “DLY” to “NORM”.

5.5 When the temperature of the outdoor coil rises highenough to causes the defrost thermostat to open, thedefrost cycle will be terminated. If at the end of theprogrammed 10 minute override time the defrost thermo-stat is still closed, the defrost board will automaticallyterminate the defrost cycle.

5.6 When the defrost cycle is terminated, the contacts of theHVDR relay on the defrost board will close to start theoutdoor fan and the contacts of the LVDR relay will openand turn off the reversing valve and electric heater(s). Theunit will now be back in a normal heating mode with a heatpump demand for heating as described in the HeatingOperation in section 4. See section 5.4a.

SEQUENCE OF OPERATIONAVPTC/MBVC with Single Stage Condensers (24VACLegacy Wired Systems)1.0 Cooling Operation1.1 On a demand for single stage cooling operation, the

thermostat closes the "G" and "Y" contacts providing24VAC to the "G", "Y1", and "Y2" terminals at theintegrated air handler control. The integrated AH controlinitiates the selected cooling ramping profile after anyblower ON delays have expired. After completing anyblower ON delays and ramping profile, the control oper-ates the variavble speed ECM motor at the demandedairflow.

1.2 The compressor and condensor fan motor is energized bythe closing of the thermostat "Y" contacts.

1.3 The system operates at single stage cooling.1.4 Upon satisfying the thermostat, the "G" and "Y" thermo-

stat contacts open, removing 24VAC from the both theoutdoor condensor and integrated air handler control.The compressor and condensor fan motor are both de-energized immediately. The integrated AH control con-tinues to operate the ECM blower motor for an OFF delayperiod, then applies the off portion of the selected rampingprofile. The ECM blower motor is then de-energized.

2.0 Heating Operation2.1 On a demand for auxiliary heat operation, the thermostat

closes the "W1" contacts providing 24VAC to the "W1"terminal at the integrated air handler control. The inte-grated AH control initiates the heating ramping profileafter any blower ON delays have expired. After complet-ing any blower ON delays and ramping profile, the controloperates the variavble speed ECM motor at the de-manded airflow.

2.2 The system operates at low stage auxiliary heat.2.3 If the thermostat demand cannot be met on low stage

auxiliary heat, the thermostat will close the "W2" con-tacts, providing 24VAC to the "W2" terminal at theintegrated AH control. Thermostat "W1" contacts re-main closed.

2.4 Upon receiving the high stage auxiliary heat demand, thecontrol operates the ECM blower motor at the demandedairflow.

2.5 The system operates at high stage auxiliary heat asdemanded by the thermostat.

2.6 Upon satisfying the thermostat, the "W1" thermostatcontacts (or "W1" and "W2" contacts) open, removing24VAC from the integrated air handler control. Theintegrated AH control continues to operate the ECMblower motor for an OFF delay period, then applies the offportion of the heating ramping profile. The ECM blowermotor is then de-energized.

3.0 Continuous Fan Operation3.1 On a demand for continuous fan operation, the thermo-

stat closes the "G" contacts providing 24VAC to the "G"terminal at the integrated air handler control. The controlenergizes the variavble speed ECM motor at 30% of theair handler's maximum airflow capability.

3.2 Removing the thermostat demand for continuous fanopens the "G" contacts, removing 24VAC from theintegrated air handler control. The integrated AH controlimmediately de-energizes the ECM blower motor.

AVPTC/MBVC with Single Stage Heat Pumps (24VACLegacy Wired Systems)1.0 Cooling Operation1.1 On a demand for single stage cooling operation, the

thermostat closes the "G", "O", and "Y" contacts provid-ing 24VAC to the "G", "O", "Y1", and "Y2" terminals attheintegrated air handler control. The integrated AH controlinitiates the selected cooling ramping profile after anyblower ON delays have expired. After completing anyblower ON delays and ramping profile, the control oper-ates the variavble speed ECM motor at the demandedairflow.

1.2 The compressor and condensor fan motor is energizedby the closing of the thermostat "Y" contacts. Thereveersing valve is energized by the closing of thethermostat "O" contacts.

1.3 The system operates at single stage cooling.1.4 Upon satisfying the thermostat, the "G", "O", and "Y"

thermostat contacts open, removing 24VAC from theboth the outdoor condensor and integrated air handlercontrol. The compressor, condensor fan motor, andreversing valve are de-energized immediately. The inte-grated AH control continues to operate the ECM blowermotor for an OFF delay period, then applies the off portionof the selected ramping profile. The ECM blower motoris then de-energized.

Page 101: Service Manual - R410a - RS6200006R32[1]

SERVICING

101

2.0 Heating Operation2.1 On a demand for heat pump heating, the room thermostat

closes the "G" and "Y" contacts, providing 24VAC to the"G" and "Y" terminals at the integrated air handlercontrol. The integrated AH control initiates the heat pumpheating ramping profile after any blower ON delays haveexpired. After completing any blower ON delays andramping profile, the control operates the variavble speedECM motor at the demanded airflow.

2.2 The compressor and condensor fan motor are energizedby the closing of the thermostat "Y" contacts.

2.3 The system operates at single stage heat pump heat.2.4 If the thermostat demand cannot be met with heat pump

heating, the thermostat will close the "W1/W2" contacts,providing 24VAC to the "W1" or "W1" and "W2" terminalsat the integrated AH control. Thermostat "G" and "Y"contacts remain closed.

2.5 Upon receiving a demand for auxiliary heat, the controldetermines the appropriate airflow demand for heat pump+ auxiliary heat operation and operates the ECM blowermotor at that airflow demand. The control determineswhich airflow demand is greatest and applies that de-mand when operating the ECM blower motor.

2.6 The system operates at single stage heat pump heatingplus auxiliary heat.

2.5 Upon satisfying the thermostat, the "G" and "Y" thermo-stat contacts (or "G", "Y" and "W1/W2" contacts) open,removing 24VAC from the integrated air handler control.The integrated AH control continues to operate the ECMblower motor for an OFF delay period, then applies the offportion of the heat pump heating ramping profile. TheECM blower motor is then de-energized.

3.0 Continuous Fan Operation3.1 On a demand for continuous fan operation, the thermostat

closes the "G" contacts providing 24VAC to the "G"terminal at the integrated air handler control. The controlenergizes the variavble speed ECM motor at 30% of theair handler's maximum airflow capability.

3.2 Removing the thermostat demand for continuous fanopens the "G" contacts, removing 24VAC from theintegrated air handler control. The integrated AH controlimmediately de-energizes the ECM blower motor.

4.0 Defrost Operation4.1 The control in the outdoor unit determines when a defrost

cycle is needed. Upon determing that a defrost cycle isneeded, the outdoor control de-energizes the condensorfan motor and energizes the reversing valve. A "W1"signal is sent from the outdoor unit control to the inte-grated air handler control.

4.2 The air handler control energizes the eletric heat se-quencer output to turn on the electric heaters. Theappropriate airflow demand is provided to the motor(greater of heat pump or auxiliary heat).

4.3 At the conclusion of the defrost cycle, the outdoor unitcontrol removes the "W1" output to the integrated airhandler control, de-energizes the reversing valve and re-energizes the condensor fan motor.

5.0 Emergency Heat Operation5.1 On a demand for emergency heat operation, the thermo-

stat closes the "W1/W2" contacts providing 24VAC tothe "W1" terminal at the integrated air handler control.The integrated AH control initiates the heating rampingprofile after any blower ON delays have expired. Aftercompleting any blower ON delays and ramping profile,the control operates the variavble speed ECM motor atthe demanded airflow.

5.2 The system operates at emergency heat.5.3 Upon satisfying the thermostat emergnecy heat de-

mand, the "W1" thermostat contacts open, removing24VAC from the integrated air handler control. Theintegrated AH control continues to operate the ECMblower motor for an OFF delay period, then applies the offportion of the heating ramping profile. The ECM blowermotor is then de-energized.

AVPTC/MBVC with 2-Stage Condensers (24VAC LegacyWired Systems)1.0 Cooling Operation1.1 On a demand for low stage cooling operation, the

thermostat closes the "G" and "Y1" contacts providing24VAC to the "G" and "Y1" terminals at the integrated airhandler control. The integrated AH control initiates theselected cooling ramping profile after any blower ONdelays have expired. After completing any blower ONdelays and ramping profile, the control operates thevariavble speed ECM motor at the demanded airflow.

1.2 The compressor and condensor fan motor are energizedby the closing of the thermostat "Y1" contacts.

1.3 The system operates at low stage cooling.1.4 If the thermostat demand cannot be met with low stage

cooling, the thermostat closes the "Y2" contacts, provid-ing 24VAC to the "Y2" terminal at the AH control. Theintegrated AH control operates the ECM blower motor atthe high stage cooling airflow demand. Thermostat "G"and Y1" contacts remain closed.

1.5 The compressor and condensor fan motor high stagespeeds are energized by the closing of the thermostat"Y2" contacts.

1.6 The system operates at high stage cooling.1.7 Upon satisfying the thermostat, the "G", "Y1" and "Y2"

thermostat contacts open, removing 24VAC from theboth the outdoor condensor and integrated air handlercontrol. The compressor and condensor fan motor areboth de-energized immediately. The integrated AHcontrol continues to operate the ECM blower motor for anOFF delay period, then applies the off portion of theselected ramping profile. The ECM blower motor is thende-energized.

Page 102: Service Manual - R410a - RS6200006R32[1]

SERVICING

102

2.0 Heating Operation2.1 On a demand for auxiliary heat operation, the thermostat

closes the "W1" contacts providing 24VAC to the "W1"terminal at the integrated air handler control. Theintegrated AH control initiates the heating rampingprofile after any blower ON delays have expired. Aftercompleting any blower ON delays and ramping profile,the control operates the variavble speed ECM motor atthe demanded airflow.

2.2 The system operates at low stage auxiliary heat.2.3 If the thermostat demand cannot be met on low stage

auxiliary heat, the thermostat will close the "W2" con-tacts, providing 24VAC to the "W2" terminal attheintegrated AH control. Thermostat "W1" contactsremain closed.

2.4 The system operates on high stage auxiliary heat.2.5 Upon receiving the high stage auxiliary heat demand, the

control operates the ECM blower motor at the high stageauxiliary heat airflow.

2.6 Upon satisfying the thermostat, the "W1" thermostatcontacts (or "W1" and "W2" contacts) open, removing24VAC from the integrated air handler control andoutdoor unit. The compressor and condensor fan motorare immediately de-enerized. The integrated AH controlcontinues to operate the ECM blower motor for an OFFdelay period, then applies the off portion of the heatingramping profile. The ECM blower motor is then de-energized.

3.0 Continuous Fan Operation3.1 On a demand for continuous fan operation, the thermo-

stat closes the "G" contacts providing 24VAC to the "G"terminal at the integrated air handler control. The controlenergizes the variavble speed ECM motor at 30% of theair handler's maximum airflow capability.

3.2 Removing the thermostat demand for continuous fanopens the "G" contacts, removing 24VAC from theintegrated air handler control. The integrated AH controlimmediately de-energizes the ECM blower motor.

AVPTC/MBVC with 2-Stage Heat Pumps (24VAC LegacyWired Systems)1.0 Cooling Operation1.1 On a demand for low stage cooling operation, the

thermostat closes the "G", "O", and "Y1" contactsproviding 24VAC to the "G", "O", and "Y1" terminals atthe integrated air handler control. The integrated AHcontrol initiates the selected cooling ramping profileafter any blower ON delays have expired. After complet-ing any blower ON delays and ramping profile, thecontrol operates the variavble speed ECM motor at thelow stage cooling airflow.

1.2 The low stage compressor and condensor fan motorspeeds are energized by the closing of the thermostat"Y1" contacts. The reversing valve is energized with theclosing of the thermostat "O" contacts.

1.3 The system operates at low stage cooling.1.4 If the thermostat demand cannot be met with low stage

cooling, the thermostat closes the "Y2" contacts, provid-ing 24VAC to the "Y2" terminal at the AH control. Theintegrated AH control operates the ECM blower motor atthe high stage cooling airflow demand. Thermostat "G","O", and Y1" contacts remain closed.

1.5 The compressor and condensor fan motor high stagespeeds are energized by the closing of the thermostat"Y2" contacts.

1.6 The system operates at high stage cooling.1.7 Upon satisfying the thermostat, the "G", "O", and "Y1"

(or "Y1" and "Y2") thermostat contacts open, removing24VAC from the both the outdoor condensor and inte-grated air handler control. The compressor, condensorfan motor, and reverving valve are all de-energized imme-diately. The integrated AH control continues to operatethe ECM blower motor for an OFF delay period, thenapplies the off portion of the selected ramping profile. TheECM blower motor is then de-energized.

2.0 Heating Operation2.1 On a demand for low stage heat pump heating, the room

thermostat closes the "G" and "Y1" contacts, providing24VAC to the"G" and "Y1" terminals at the integrated airhandler control. The integrated AH control initiates theheat pump heating ramping profile after any blower ONdelays have expired. After completing any blower ONdelays and ramping profile, the control operates thevariavble speed ECM motor at the low stage heat pumpairflow.

2.2 The low stage compressor and condensor fan motorspeeds are energized by the closing of the thermostat"Y1" contacts.

2.3 The system operates at low stage heat pump heating.2.4 If the thermostat demand cannot be met with low stage

heat pump heating, the thermostat will close the "Y2"contacts, providing 24VAC to the "Y2" terminals at theintegrated AH control and heat pump. Thermostat "G"and "Y1" contacts remain closed. The air handler controloperates the ECM blower motor at the high stage heatpump heating airflow.

2.5 The system operates at high stage heat pump heating.2.6 If the thermostat demand cannot be met with high stage

heat pump heating, the thermostat will close the "W1/W2" contacts, providing 24VAC to the "W1" or "W1" and"W2" terminals at the integrated AH control. Thermostat"G", "Y1", and "Y2" contacts remain closed.

2.7 Upon receiving a demand for auxiliary heat, the controldetermines the appropriate airflow demand for high stageheat pump + auxiliary heat operation and operates theECM blower motor at that airflow demand. The controldetermines which airflow demand is greatest and appliesthat demand when operating the ECM blower motor.

Page 103: Service Manual - R410a - RS6200006R32[1]

SERVICING

103

2.8 The system operates at high stage heat pump heatingplus auxiliary heat.

2.9 Upon satisfying the thermostat, the "G" and "Y1" thermo-stat contacts (or "G", "Y1", "Y2" and "W1/W2" contacts)open, removing 24VAC from the integrated air handlercontrol. The compressor and condensor fan motor arede-energized immediately. The integrated AH controlcontinues to operate the ECM blower motor for an OFFdelay period, then applies the off portion of the heat pumpheating ramping profile. The ECM blower motor is thende-energized.

3.0 Continuous Fan Operation3.1 On a demand for continuous fan operation, the thermo-

stat closes the "G" contacts providing 24VAC to the "G"terminal at the integrated air handler control. The controlenergizes the variavble speed ECM motor at 30% of theair handler's maximum airflow capability.

3.2 Removing the thermostat demand for continuous fanopens the "G" contacts, removing 24VAC from theintegrated air handler control. The integrated AH controlimmediately de-energizes the ECM blower motor.

4.0 Defrost Operation4.1 The control in the outdoor unit determines when a defrost

cycle is needed. Upon determing that a defrost cycle isneeded, the outdoor control de-energizes the condensorfan motor and energizes the reversing valve. A "W1"signal is sent from the outdoor unit control to theintegrated air handler control.

4.2 The air handler control energizes the eletric heat se-quencer output to turn on the electric heaters. Theappropriate airflow demand is provided to the motor(greater of heat pump or auxiliary heat).

4.3 At the conclusion of the defrost cycle, the outdoor unitcontrol removes the "W1" output to the integrated airhandler control, de-energizes the reversing valve and re-energizes the condensor fan motor.

5.0 Emergency Heat Operation5.1 On a demand for emergency heat operation, the thermo-

stat closes the "W1/W2" contacts providing 24VAC tothe "W1" terminal at the integrated air handler control.The integrated AH control initiates the heating rampingprofile after any blower ON delays have expired. Aftercompleting any blower ON delays and ramping profile,the control operates the variavble speed ECM motor atthe emergency heat airflow.

5.2 The system operates at emergency heat.5.3 Upon satisfying the thermostat emergnecy heat de-

mand, the "W1" thermostat contacts open, removing24VAC from the integrated air handler control. Theintegrated AH control continues to operate the ECMblower motor for an OFF delay period, then applies the offportion of the heating ramping profile. The ECM blowermotor is then de-energized

AVPTC/MBVC with ASXC/DSXC Condenser and CTK0*Communicating ThemostatThe AVPTC or MBVC air handle/modular blower matchedwith an ASXC or DSXC condensing unit and CTK0* commu-nicating thermostat constitute a network. The three compo-nents, or subsystems, making up the system communicatewith one another with information passed between all threecomponents. This leads to a somewhat non-traditionalmanner in which the system components receive commandsfor system operation. All system commands are routed fromthe component through the network to the appropriate desti-nation component.NOTE: The individual subsystems will cease operation if therequest for operation is NOT refreshed after 5 minutes. Thisis a built-in safe guard to prevent the possibility of runawayoperation.1.0 Cooling Operation - Low and High Stage Cool1.1 The CTK0* thermostat sends a request for low stage

cooling through the network to the unitary (UC) control inthe condenser. The UC control receives the commandand processes any compressor and fan delays.

1.2 The UC control sends a request for low stage fan speedto the air handler/modular blower. The blower energizesthe ECM blower motor at the appropriate speed.

1.3 The condenser energizes the compressor and con-denser fan motor at the appropriate low stage speeds.

1.4 The system operates at low stage cooling.1.5 If the thermostat demand cannot be met on low stage

cooling, the CTK0* thermostat sends a request for highstage cooling to the condenser. The condenser in turnsends a request for high stage fan speed to the airhandler/modular blower. The blower increases the blowerspeed to the high stage cooling speed.

1.6 The condenser's unitary control energizes the high stagecompressor solenoid and switches the condenser fanmotor to high speed.

1.7 The system operates at high stage cooling.1.8 Once the thermostat demand is satisfied, the CTK0*

thermostat commands the UC control to end coolingoperation. The condenser de-energizes thecompressorand condenser fan motor. The UC controlcontinues providing a fan request until any cooling blowerOFF delays have expired.

2.0 Heating Operation - Auxiliary/Emergency Heat2.1 The CTK0* thermostat sends a request for emergency

heat to the air handler/modular blower.2.2 The air handler control energizes the ECM blower motor

at the emergency heat speed. The electric heat se-quencer outputs are also energized, thus energizing theelectric heaters.

2.3 The system operates at emergency heat.

Page 104: Service Manual - R410a - RS6200006R32[1]

SERVICING

104

2.4 Once the thermostat demand is satisfied, the CTK0*thermostat commands the air handler/modular blower toend emergency heat operation. The air handler controlde-energizes the electric heat sequencer outputs. TheECM blower motor remains energized until any blowerOFF delay timing has expired.

3.0 Continuous Fan Operation3.1 With a demand for continuous fan operation, the CTK0*

thermostat sends a fan request to the integrated airhandler control along with a fan demand. The controlenergizes the variavble speed ECM motor at fan demandprovided by the thermostat. The fan demand provided bythe thermostat will be 30%, 50%,or 70% of the airhandler's maximum airflow capability. The continuousfan demand is set from the thermostat as low, medium,or high.

3.2 If the thermostat demand for continuous fan is removed,the CTK0* thermostat commands the integrated airhandler control to end continuous fan operation. Theintegrated AH control immediately de-energizes theECM blower motor.

AVPTC/MBVC with ASZC/DSZC Heat Pump and CTK0*Communicating ThemostatThe AVPTC or MBVC air handle/modular blower matchedwith an ASZC or DSZC condensing unit and CTK0* commu-nicating thermostat constitute a network. The three compo-nents, or subsystems, making up the system communicatewith one another with information passed between all threecomponents. This leads to a somewhat non-traditionalmanner in which the system components receive commandsfor system operation. All system commands are routed fromthe component through the network to the appropriate des-tination component.NOTE: Communicating heat pump systems are designed toutilize a balance point temperature. The balance pointtemperature in part controls heat pump operation. If theoutdoor temperature is below the balance point, the heatpump is disable and only electric heat is available for heating.The balance point temperature is set via the CTK0* thermo-stat in the advanced installer's configuration menu.The CTK0* thermostat also allows the user to disable theelectric heaters in the air handler/modular blower dependingon the outdoor temperature. The electric heaters are dis-abled If the outdoor temperature is above the set point. Allheating is supplied by the heat pump.The outdoor air temperature is aquired from the outdoor airtemperature (OAT) sensor included with the ASZC/DSZCheat pump models. Faults with the sensor will affect heatingoperation.NOTE: The individual subsystems will cease operation if therequest for operation is NOT refreshed after 5 minutes. Thisis a built-in safe guard to prevent the possibility of runawayoperation.

1.0 Cooling Operation - Low and High Stage Cool1.1 The CTK0* thermostat sends a request for low stage

cooling through the network to the unitary (UC) control inthe heat pump. The UC control receives the commandand processes any compressor and fan delays.

1.2 The UC control sends a request for low stage fan speedto the air handler/modular blower. The blower energizesthe ECM blower motor at the appropriate speed.

1.3 The heat pump energizes the compressor and condenserfan motor at the appropriate low stage speeds. Thereversing valve is also energized.

1.4 The system operates at low stage cooling.1.5 If the thermostat demand cannot be met on low stage

cooling, the CTK0* thermostat sends a request for highstage cooling to the heat pump. The heat pump in turnsends a request for high stage fan speed to the airhandler/modular blower. The AH control increases theblower speed to the high stage cooling speed.

1.6 The heat pump's unitary control energizes the high stagecompressor solenoid and switches the condenser fanmotor to high speed. The reversing valve remainsenergized.

1.7 The system operates at high stage cooling.1.8 Once the thermostat demand is satisfied, the CTK0*

thermostat commands the UC control to end coolingoperation. The heat pump de-energizes the compressor,condenser fan motor, and reversing valve. The UC controlcontinues providing a fan request until any cooling blowerOFF delays have expired.

2.0 Heating Operation Outdoor Temperature Above the Heat Pump BalancePoint2.1 The CTK0* thermostat sends a request for the outdoor air

temperature to the heat pump. The heat pump returns anoutdoor air temperature that is above the balance pointtemperature. Heat pump heating is enabled.

2.2 The CTK0* thermostat sends a request for low stage heatpump heating to the unitary (UC) control in the heatpump. The UC control receives the command andprocesses any compressor and fan delays.

2.3 The UC control sends a request for low stage fan speedto the air handler/modular blower. The blower energizesthe ECM blower motor at the appropriate speed.

2.4 The condenser energizes the compressor and con-denser fan motor at the appropriate low stage speeds.

2.5 The system operates at low stage heat pump heating.2.6 If the thermostat demand cannot be met on low stage

heat pump heating, the CTK0* thermostat sends arequest for high stage heat pump heating to the heatpump. The heat pump in turn sends a request for highstage fan speed to the air handler/modular blower. TheAH control increases the blower speed to the high stageheat pump heating speed.

Page 105: Service Manual - R410a - RS6200006R32[1]

SERVICING

105

2.7 The heat pump's unitary control energizes the high stagecompressor solenoid and switches the condenser fanmotor to high speed.

2.8 The system operates at high stage heat pump heating.2.9 If the thermostat demand cannot be met on high stage

heat pump heating, the CTK0* thermostat sends a re-quest for auxiliary heat to the air handler/modular blower.

2.10 Upon receiving a demand for auxiliary heat, the airhandler control determines the appropriate airflow for highstage heat pump + auxiliary heat operation and operatesthe ECM blower motor at that airflow demand. The airhandler control determines which airflow demand is great-est and applies that demand when operating the ECMblower motor.

2.11 The system operates at high stage heat pump heatingplus auxiliary heat.

2.12 Once the thermostat demand is satisfied, the CTK0*thermostat commands the heat pump to end heat pumpheating operation. The compressor and outdoor fanmotor are de-energized.

The air handler/modular blower is commanded to endauxiliary heat operation. The air handler control de-energizes the electric heat sequencer outputs. The ECMblower motor remains energized until any blower OFFdelay timing has expired.

Outdoor Temperature Below the Heat Pump BalancePoint2.1 The CTK0*** thermostat sends a request for the outdoor

air temperature to the heat pump. The heat pump returnsan outdoor air temperature that is below the balance pointtemperature. Heat pump heating is disabled.

2.2 The CTK0*** thermostat sends a request for auxiliary heatto the air handler/modular blower.

2.2 The air handler control energizes the ECM blower motorat the auxiliary heat speed. The electric heat sequenceroutputs are also energized, thus energizing the electricheaters.

2.3 The system operates at auxiliary heat.2.4 Once the thermostat demand is satisfied, the CTK0*

thermostat commands the air handler/modular blower toend auxiliary heat operation. The air handler control de-energizes the electric heat sequencer outputs. The ECMblower motor remains energized until any blower OFFdelay timing has expired.

3.0 Continuous Fan Operation3.1 With a demand for continuous fan operation, the CTK0*

thermostat sends a fan request to the integrated airhandler control along with a fan demand. Thecontroladjustable via the CTK0* thermostat. The com-pressor delay is intended to eliminate compressor noiseduring the reversing valve shift.) The compressor willenergized (or re-energized) at high stage.

3.2 If the thermostat demand for continuous fan is removed,the CTK0* thermostat commands the integrated airhandler control to end continuous fan operation. Theintegrated AH control immediately de-energizes theECM blower motor.

4.0 Defrost Operation4.1 While the system is operating in heat pump heating (see

2.0 Heating Operation), the control in the outdoor unitmay determines that a defrost cycle is needed. Upondeterming that a defrost cycle is needed, the UC controlde-energizes the condensor fan motor and energizes thereversing valve.

4.2 The compressor may be de-energized for a short delayduring the reversing valve shift. (The delay period isadjustable via the CTK0* thermostat. The compressordelay is intended to eliminate compressor noise duringthe reversing valve shift.) The compressor will energize(or re-energize) at high stage.

4.3 The UC control sends a request for defrost operation tothe integrated air handler control. The air handler controlenergizes the electric heat sequencer outputs and oper-ates the ECM blower model at the electric heat speed.

4.4 Once the defrost cycle is terminated, the heat pumpcommands the air handler/modular blower to end defrostoperation.

4.5 The system returns to heat pump heating operation thatwas in effect prior to the defrost cycle.

5.0 Emergency Heat Operation5.1 The CTK0* thermostat sends a request for emergency

heat to the air handler/modular blower.5.2 The air handler control energizes the ECM blower motor

at the emergency heat speed. The electric heat se-quencer outputs are also energized, thus energizing theelectric heaters.

5.3 The system operates at emergency heat.5.4 Once the thermostat demand is satisfied, the CTK0*

thermostat commands the air handler/modular blower toend emergency heat operation. The air handler controlde-energizes the electric heat sequencer outputs. TheECM blower motor remains energized until any blowerOFF delay timing has expired. energizes the variavblespeed ECM motor at fan demand provided by the thermo-stat. The fan demand provided by the thermostat will be30%, 50%,or 70% of the air handler's maximum airflowcapability. The continuous fan demand is set from thethermostat as low, medium, or high.

S-50 CHECKING HEATER LIMIT CONTROL(S)(OPTIONAL ELECTRIC HEATERS)Each individual heater element is protected with an automaticrest limit control connected in series with each element toprevent overheating of components in case of low airflow. Thislimit control will open its circuit at approximately 150°F. to160°F and close at approximately 110°F.

Page 106: Service Manual - R410a - RS6200006R32[1]

SERVICING

106

WARNINGDisconnect ALL power before servicing.

1. Remove the wiring from the control terminals.2. Using an ohmmeter test for continuity across the nor-

mally closed contacts. No reading indicates the controlis open - replace if necessary. Make sure the limits arecool before testing.

IF FOUND OPEN - REPLACE - DO NOT WIRE AROUND.

S-52 CHECKING HEATER ELEMENTSOptional electric heaters may be added, in the quantitiesshown in the spec sheet for each model unit, to provideelectric resistance heating. Under no condition shall moreheaters than the quantity shown be installed.

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Disassemble and remove the heating element(s).2. Visually inspect the heater assembly for any breaks in

the wire or broken insulators.3. Using an ohmmeter, test the element for continuity - no

reading indicates the element is open. Replace asnecessary.

S-60 ELECTRIC HEATER (OPTIONAL ITEM)Optional electric heaters may be added, in the quantitiesshown in the specifications section, to provide electricresistance heating. Under no condition shall more heatersthan the quantity shown be installed.The low voltage circuit in the air handler is factory wired andterminates at the location provided for the electric heater(s).A minimum of field wiring is required to complete the instal-lation.Other components such as a Heating/Cooling Thermostatand Outdoor Thermostats are available to complete theinstallation.The system CFM can be determined by measuring the staticpressure external to the unit. The installation manualsupplied with the blower coil, or the blower performance tablein the service manual, shows the CFM for the static mea-sured.Alternately, the system CFM can be determined by operatingthe electric heaters and indoor blower WITHOUT having thecompressor in operation. Measure the temperature rise asclose to the blower inlet and outlet as possible.

If other than a 240V power supply is used, refer to the BTUHCAPACITY CORRECTION FACTOR chart below.

BTUH CAPACITY CORRECTION FACTOR

SUPPLY VOLTAGE 250 230 220 208

MULTIPLICATION FACTOR 1.08 .92 .84 .75

EXAMPLE: Five (5) heaters provide 24.0 KW at the rated240V. Our actual measured voltage is 220V, and ourmeasured temperature rise is 42°F. Find the actual CFM:Answer: 24.0KW, 42°F Rise, 240 V = 1800 CFM from theTEMPERATURE RISE chart on the right.Heating output at 220 V = 24.0KW x 3.413 x .84 = 68.8MBH.Actual CFM = 1800 x .84 Corr. Factor = 1400 CFM.NOTE: The temperature rise table is for sea level installa-tions. The temperature rise at a particular KW and CFM willbe greater at high altitudes, while the external static pres-sure at a particular CFM will be less.

CFM 3.0 kW

4.8 kW

7.2 kW

9.6 kW

14.4 kW

19.2 kW

24.0 kW

28.8 kW

600 16 25 38 51 - - - -700 14 22 33 43 - - - -800 12 19 29 38 57 - - -900 11 17 26 34 51 - - -

1000 10 15 23 30 46 - - -1100 9 14 21 27 41 55 - -1200 8 13 19 25 38 50 - -1300 7 12 18 23 35 46 - -1400 7 11 16 22 32 43 54 651500 6 10 15 20 30 40 50 601600 6 9 14 19 28 38 47 571700 6 9 14 18 27 36 44 531800 5 8 13 17 25 34 42 501900 5 8 12 16 24 32 40 482000 5 8 12 15 23 30 38 452100 5 7 11 14 22 29 36 432200 4 7 11 14 21 27 34 412300 4 7 10 13 20 26 33 39

TEMPERATURE RISE (°F) @ 240V

HTRKW

3.0KW

4.7KW

6.0KW

7.0KW

9.5KW

14.2KW

19.5KW

21.0KW

BTUH 10200 16200 20400 23800 32400 48600 66500 71600

ELECTRIC HEATER CAPACITY BTUH

Page 107: Service Manual - R410a - RS6200006R32[1]

SERVICING

107

FORMULAS:Heating Output = KW x 3413 x Corr. Factor

Actual CFM = CFM (from table) x Corr. Factor

BTUH = KW x 3413

BTUH = CFM x 1.08 x Temperature Rise (T)

CFM = KW x 34131.08 x T

T = BTUH CFM x 1.08

S-61A CHECKING HEATER LIMIT CONTROL(S)Each individual heater element is protected with a limit controldevice connected in series with each element to preventoverheating of components in case of low airflow. This limitcontrol will open its circuit at approximately 150°F.

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Remove the wiring from the control terminals.2. Using an ohmmeter, test for continuity across the nor-

mally closed contacts. No reading indicates the controlis open - replace if necessary.

IF FOUND OPEN - REPLACE - DO NOT WIRE AROUND.

S-61B CHECKING HEATER FUSE LINK

(OPTIONAL ELECTRIC HEATERS)

Each individual heater element is protected with a one timefuse link which is connected in series with the element. Thefuse link will open at approximately 333°.

WARNINGDisconnect ALL power before servicing.

1. Remove heater element assembly so as to expose fuselink.

2. Using an ohmmeter, test across the fuse link for continuity- no reading indicates the link is open. Replace asnecessary.

NOTE: The link is designed to open at approximately 333°F.DO NOT WIRE AROUND - determine reason for failure.

S-62 CHECKING HEATER ELEMENTS

WARNINGDisconnect ALL power before servicing.

1. Disassemble and remove the heating element.2. Visually inspect the heater assembly for any breaks in

the wire or broken insulators.3. Using an ohmmeter, test the element for continuity - no

reading indicates the element is open. Replace asnecessary.

S-100 REFRIGERATION REPAIR PRACTICE

DANGERAlways remove the refrigerant charge in a propermanner before applying heat to the system.

When repairing the refrigeration system:

HIGH VOLTAGE!Disconnect ALL power before servicingor installing. Multiple power sourcesmay be present. Failure to do so maycause property damage, personal injuryor death.

1. Never open a system that is under vacuum. Air andmoisture will be drawn in.

2. Plug or cap all openings.3. Remove all burrs and clean the brazing surfaces of the

tubing with sand cloth or paper. Brazing materials donot flow well on oxidized or oily surfaces.

4. Clean the inside of all new tubing to remove oils and pipechips.

5. When brazing, sweep the tubing with dry nitrogen toprevent the formation of oxides on the inside surfaces.

6. Complete any repair by replacing the liquid line drier inthe system, evacuate and charge.

BRAZING MATERIALSIMPORTANT NOTE: Torch heat required to braze tubes ofvarious sizes is proportional to the size of the tube. Tubesof smaller size require less heat to bring the tube to brazingtemperature before adding brazing alloy. Applying toomuch heat to any tube can melt the tube. Service personnelmust use the appropriate heat level for the size of the tubebeing brazed.NOTE: The use of a heat shield when brazing isrecommended to avoid burning the serial plate or the finishon the unit. Heat trap or wet rags should be used to protectheat sensitive components such as service valves and TXVvalves.

Page 108: Service Manual - R410a - RS6200006R32[1]

SERVICING

108

Copper to Copper Joints - Sil-Fos used without flux (alloyof 15% silver, 80% copper, and 5% phosphorous). Recom-mended heat 1400°F.Copper to Steel Joints - Silver Solder used without a flux(alloy of 30% silver, 38% copper, 32% zinc). Recommendedheat - 1200°F.

S-101 LEAK TESTING (NITROGEN OR NITRO-GEN-TRACED)

To avoid the risk of fire or explosion, never useoxygen, high pressure air or flammable gases for leaktesting of a refrigeration system.

WARNING

To avoid possible explosion, the line from thenitrogen cylinder must include a pressure regulatorand a pressure relief valve. The pressure relief valvemust be set to open at no more than 150 psig.

WARNING

Pressure test the system using dry nitrogen and soapy waterto locate leaks. If you wish to use a leak detector, charge thesystem to 10 psi using the appropriate refrigerant then usenitrogen to finish charging the system to working pressure,then apply the detector to suspect areas. If leaks are found,repair them. After repair, repeat the pressure test. If no leaksexist, proceed to system evacuation.

S-102 EVACUATION

WARNINGREFRIGERANT UNDER PRESSURE!Failure to follow proper procedures may causeproperty damage, personal injury or death.

IMPORTANT NOTE: Because of the potential damage tocompressors, do not allow suction pressure at service valveto drop below 20 PSIG when pumping unit system down forrepair. Outdoor section, depending on line set length andamount of charge in system, may not be able to hold theentire system charge.This is the most important part of the entire service proce-dure. The life and efficiency of the equipment is dependentupon the thoroughness exercised by the serviceman whenevacuating air (non-condensables) and moisture from thesystem.Air in a system causes high condensing temperature andpressure, resulting in increased power input and reducedperformance.Moisture chemically reacts with the refrigerant oil to formcorrosive acids. These acids attack motor windings andparts, causing breakdown.

The equipment required to thoroughly evacuate the system isa high vacuum pump, capable of producing a vacuum equiva-lent to 25 microns absolute and a thermocouple vacuumgauge to give a true reading of the vacuum in the systemNOTE: Never use the system compressor as a vacuum pumpor run when under a high vacuum. Motor damage could occur.

Do not front seat the service valve(s) with thecompressor open, with the suction line of thecomprssor closed or severely restricted.

WARNING

1. Connect the vacuum pump, vacuum tight manifold setwith high vacuum hoses, thermocouple vacuum gaugeand charging cylinder as shown.

2. Start the vacuum pump and open the shut off valve to thehigh vacuum gauge manifold only. After the compoundgauge (low side) has dropped to approximately 29 inchesof vacuum, open the valve to the vacuum thermocouplegauge. See that the vacuum pump will blank-off to amaximum of 25 microns. A high vacuum pump can onlyproduce a good vacuum if its oil is non-contaminated.

LOW SIDEGAUGE

AND VALVE

HIGH SIDEGAUGE

AND VALVE

TO UNIT SERVICEVALVE PORTS

VACUUM PUMP

VACUUM PUMPADAPTER

800 PSIRATEDHOSES

CHARGINGCYLINDER

AND SCALE

EVACUATION

3. If the vacuum pump is working properly, close the valve tothe vacuum thermocouple gauge and open the high andlow side valves to the high vacuum manifold set. With thevalve on the charging cylinder closed, open the manifoldvalve to the cylinder.

4. Evacuate the system to at least 29 inches gauge beforeopening valve to thermocouple vacuum gauge.

5. Continue to evacuate to a maximum of 250 microns.

Page 109: Service Manual - R410a - RS6200006R32[1]

SERVICING

109

Close valve to vacuum pump and watch rate of rise. Ifvacuum does not rise above 1500 microns in three to fiveminutes, system can be considered properly evacuated.

6. If thermocouple vacuum gauge continues to rise andlevels off at about 5000 microns, moisture and non-condensables are still present. If gauge continues to risea leak is present. Repair and re-evacuate.

7. Close valve to thermocouple vacuum gauge and vacuumpump. Shut off pump and prepare to charge.

S-103 CHARGING

WARNINGREFRIGERANT UNDER PRESSURE!* Do not overcharge system with refrigerant.* Do not operate unit in a vacuum or at negative pressure.Failure to follow proper procedures may causeproperty damage, personal injury or death.

CAUTIONUse refrigerant certified to AHRI standards. Usedrefrigerant may cause compressor damage and willvoid the warranty. Most portable machines cannotclean used refrigerant to meet AHRI standards.

CAUTIONOperating the compressor with the suction valveclosed will void the warranty and cause seriouscompressor damage.

Charge the system with the exact amount of refrigerant.Refer to the specification section or check the unit name-plates for the correct refrigerant charge.An inaccurately charged system will cause future prob-lems.1. When using an ambient compensated calibrated charg-

ing cylinder, allow liquid refrigerant only to enter the highside.

2. After the system will take all it will take, close the valveon the high side of the charging manifold.

3. Start the system and charge the balance of the refrigerantthrough the low side.

NOTE: R410A should be drawn out of the storage containeror drum in liquid form due to its fractionation properties, butshould be "Flashed" to its gas state before entering thesystem. There are commercially available restriction devicesthat fit into the system charging hose set to accomplish this.DO NOT charge liquid R410A into the compressor.

4. With the system still running, close the valve on thecharging cylinder. At this time, you may still have someliquid refrigerant in the charging cylinder hose and willdefinitely have liquid in the liquid hose. Reseat the liquidline core. Slowly open the high side manifold valve andtransfer the liquid refrigerant from the liquid line hose andcharging cylinder hose into the suction service valve port.CAREFUL: Watch so that liquid refrigerant does notenter the compressor.

Final Charge Adjustment

The outdoor temperature must be 60°F or higher. Set theroom thermostat to COOL, fan switch to AUTO, and set thetemperature control well below room temperature.After system has stabilized per startup instructions, com-pare the operating pressures and outdoor unit amp draw tothe numbers listed on the performance label on the outdoorunit. If pressures and amp draw are too low, add charge. Ifpressures and amp draw are too high, remove charge. Checksubcooling and superheat as detailed in the following section.5. With the system still running, remove hose and reinstall

both valve caps.6. Check system for leaks.

Do not charge a remote condensing unit with a non-matchingevaporator coil, or a system where the charge quantity isunknown. Do not install or charge R410A condensers matchedwith coils having capillary tubes or flow control restrictors.AHRI rated Coil combinations with thermostatic expansionvalves (TEV's) should be charged by subcooling. See"Checking Subcooling and Superheat" sections in this manual.Subcooling values for "Ultron" system are found in theTechnical Information manuals for "Ultron" outdoor units.Due to their design, Scroll compressors are inherently moretolerant of liquid refrigerant.NOTE: Even though the compressor section of a Scrollcompressor is more tolerant of liquid refrigerant, continuedfloodback or flooded start conditions may wash oil from thebearing surfaces causing premature bearing failure.

S-104 CHECKING COMPRESSOR EFFICIENCYThe reason for compressor inefficiency is broken or damagedscroll flanks on Scroll compressors, reducing the ability of thecompressor to pump refrigerant vapor.The condition of the scroll flanks is checked in the followingmanner.1. Attach gauges to the high and low side of the system.2. Start the system and run a "Cooling Performance Test.If the test shows:a. Below normal high side pressure.b. Above normal low side pressure.c. Low temperature difference across coil.d. Low amp draw at compressor.

And the charge is correct. The compressor is faulty - replacethe compressor.

Page 110: Service Manual - R410a - RS6200006R32[1]

SERVICING

110

S-105A PISTON CHART FOR

ASX13, GSX13, VSX13, SSX14, ASX14, GSX14, ASZ13, GSZ13, GSZ14, VSZ13, SSZ14 UNITSG

SX

1301

81(B

,C,D

)*V

SX1

3018

1(A

,B,D

)*A

SX1

3018

1(B

,C,D

)*W

AC

4318

AC

*W

GA

C43

18A

C*

All

AHR

I Mat

ches

0.05

1B

1789

851

1G

SX

1302

41(B

,C,D

)*V

SX1

3024

1(A

,B,D

)*A

SX

1302

41(B

,C)*

WA

C43

24A

B*

WG

AC

4324

AB

*A

ll A

HRI M

atch

es0.

057

B17

8985

71

GS

X13

0301

(B,D

)*V

SX

1303

01(A

,D)*

AS

X13

0301

(B,C

)*W

AC

4330

AB

*W

GA

C43

30A

B*

All

AHR

I Mat

ches

0.06

1B

1789

861

1G

SX

1303

61B

*VS

X13

0361

A*

AS

X13

0361

(B,C

)*W

AC

4336

AB

*W

GA

C43

36A

B*

All

AHR

I Mat

ches

0.07

0B

1789

870

1G

SX

1303

61D

*VS

X13

0361

D*

All

AHR

I Mat

ches

0.06

7B

1789

867

1G

SX

1303

63A

*A

ll A

HRI M

atch

es0.

070

B17

8987

01

GS

X13

0421

B*

VS

X13

0421

(A,B

)*A

SX

1304

21(B

,C)*

WA

C43

42A

B*

WG

AC

4342

AB

*A

ll A

HRI M

atch

es0.

076

B17

8987

61

GS

X13

0481

B*

VSX

1304

81A

*A

SX

1304

81(B

,C)*

WA

C43

48A

B*

WG

AC

4348

AB

*A

ll A

HRI M

atch

es0.

080

B17

8988

01

VSX

1304

81B

*C

SC

F486

0

All

Oth

er A

HR

I Mat

ches

0.08

0

0.

078

B17

8988

0 B

1789

878

2

1G

SX

1304

83A

*A

ll A

HRI M

atch

es0.

080

B17

8988

01

GS

X13

0484

A*

All

AHR

I Mat

ches

0.08

0B

1789

880

1G

SX

1306

01B

*VS

X13

0601

B*

AS

X13

0601

(B,C

)*W

AC

4360

AB

*W

GA

C43

60A

B*

All

AHR

I Mat

ches

0.08

6B

1789

886

1G

SX

1306

03A

*A

ll A

HRI M

atch

es0.

086

B17

8988

61

GS

X13

0604

A*

All

AHR

I Mat

ches

0.08

6B

1789

886

1

GS

X14

0181

A*

SSX

1401

81B

*A

SX1

4018

1(B

,C,D

)*W

AC

4418

AB

*W

GA

C44

18A

B*

AW

UF3

1 &

32

All

othe

r AH

RI M

atch

es0.

051

0.

052

B17

8985

1

B17

8985

22

1

GS

X14

0241

A*

SSX

1402

41B

*A

SX

1402

41(B

,C)*

WA

C44

24A

B*

WG

AC

4424

AB

*A

WU

F 31

All

Oth

er A

HR

I Mat

ches

0.05

7

0.

055

B17

8985

7

B17

8985

52

1

GS

X14

0301

A*

SSX

1403

01B

*A

SX

1403

01(B

,C)*

WA

C44

30A

B*

WG

AC

4430

AB

*AW

UF

31 &

32

All

Oth

er A

HR

I Mat

ches

0.06

1

0.

065

B17

8986

1

B17

8986

53

1

GS

X14

0361

A*

SSX

1403

61B

*A

SX

1403

61(B

,C)*

WA

C44

36A

B*

WG

AC

4436

AB

*A

ll A

HRI M

atch

es0.

068

B17

8986

81

GS

X14

0421

A*

SS

X14

0421

C*

AS

X14

0421

(C,D

)*W

AC

4442

AC

*W

GA

C44

42A

C*

All

AHR

I Mat

ches

0.07

0B

1789

870

1G

SX

1404

81A

*SS

X14

0481

B*

AS

X14

0481

C*

WA

C44

48A

B*

WG

AC

4448

AB

*A

ll A

HRI M

atch

es0.

078

B17

8987

81

SSX

1404

81A

*AS

X14

0481

B*

WA

C44

48A

A*

WG

AC

4448

AA

*A

ll A

HRI M

atch

es0.

079

B17

8987

91

GS

X14

0601

A*

SSX

1406

01A

*A

SX

1406

01(A

,B)*

WA

C44

60A

A*

WG

AC

4460

AA

*A

ll A

HRI M

atch

es0.

088

B17

8988

81

SSX

1602

41B

*W

AC

4624

AB

*W

GA

C46

24A

B*

All

AHR

I Mat

ches

TX

V o

nly

TX2N

4A3

SSX

1603

01A

*W

AC

4630

AA

*A

ll A

HRI M

atch

esT

XV

onl

yTX

3N4

3S

SX

1603

61(A

,B)*

WA

C46

36A

B*

WG

AC

4636

AB

*A

ll A

HRI M

atch

esT

XV

onl

yTX

3N4

3SS

X16

0421

A*

WA

C46

42A

A*

All

AHR

I Mat

ches

TX

V o

nly

TX5N

43

SS

X16

0481

(A,B

)*W

AC

4648

A(A

,B)*

WG

AC

4648

A(A

,B)*

All

AHR

I Mat

ches

TX

V o

nly

TX5N

43

SSX

1605

91A

*W

AC

4659

AA

*A

ll A

HRI M

atch

esT

XV

onl

yTX

5N4

3S

SX

1606

01(A

,B)*

WG

AC

4660

AA

*A

ll A

HRI M

atch

esT

XV

onl

yTX

5N4

3

Out

door

Uni

tN

ote

Indo

or U

nit

Indo

or

Pis

ton

Size

Pis

ton

Kit

P/N

PIST

ON

KIT

CH

AR

T

110

(*)

SIG

NIF

IES

UN

IT R

EV

ISIO

N.

(1)

CO

RR

EC

T P

ISTO

N IS

SU

PP

LIE

D W

ITH

TH

E O

UTD

OO

R U

NIT

.(2

)C

OR

RE

CT

PIS

TON

IS S

UP

PLI

ED

IN T

HE

HIG

HE

ST

SA

LES

VO

LUM

E T

ES

TED

CO

MB

INAT

ION

IND

OO

RU

NIT

. FO

R A

LL O

THE

R IN

DO

OR

CO

MB

INAT

ION

S, P

ISTO

N M

US

T B

E P

UR

CH

AS

ED

FR

OM

DIS

TRIB

UTO

R.

(3)

TXV

MU

ST B

E PU

RC

HAS

ED S

EPAR

ATEL

Y.

IT IS ESSEN

TIAL TH

AT IN

DOOR AND OUTD

OOR UNITS BE PR

OPE

RLY MATC

HED. F

AILURE TO FOLLOW THESE INSTRUCT

IONS OR TO 

PROPE

RLY MATC

H EVAPO

RATO

RS AND CONDEN

SERS CAN RESULT IN UNIT DAMAGE, PRO

PERT

Y DAMAGE AND/O

R PE

RSONAL INJURY. 

NO W

ARR

ANTY CLA

IM W

ILL BE HONORE

D FOR M

IX‐M

ATC

HED SYSTEMS TH

AT FA

IL TO ADHER

E TO THE SP

ECIFIED PISTO

N SIZE.

WA

RN

ING

Page 111: Service Manual - R410a - RS6200006R32[1]

SERVICING

111

IT IS ESSEN

TIAL TH

AT IN

DOOR AND OUTD

OOR UNITS BE PR

OPE

RLY MATC

HED. F

AILURE TO FOLLOW THESE INSTRUCT

IONS OR TO 

PROPE

RLY MATC

H EVAPO

RATO

RS AND CONDEN

SERS CAN RESULT IN UNIT DAMAGE, PRO

PERT

Y DAMAGE AND/O

R PE

RSONAL INJURY. 

NO W

ARR

ANTY CLA

IM W

ILL BE HONORE

D FOR M

IX‐M

ATC

HED SYSTEMS TH

AT FA

IL TO ADHER

E TO THE SP

ECIFIED PISTO

N SIZE.

WA

RN

ING

(*)

SIG

NIF

IES

UN

IT R

EV

ISIO

N.

(1)

CO

RR

EC

T P

ISTO

N IS

SU

PP

LIE

D W

ITH

TH

E O

UTD

OO

R U

NIT

.(2

)C

OR

RE

CT

PIS

TON

IS S

UP

PLI

ED

IN T

HE

HIG

HE

ST

SA

LES

VO

LUM

E T

ES

TED

CO

MB

INAT

ION

IND

OO

RU

NIT

. FO

R A

LL O

THE

R IN

DO

OR

CO

MB

INAT

ION

S, P

ISTO

N M

US

T B

E P

UR

CH

AS

ED

FR

OM

DIS

TRIB

UTO

R.

(3)

TXV

MU

ST B

E PU

RC

HAS

ED S

EPAR

ATEL

Y.

PIST

ON

KIT

CH

AR

T

DSX

C16

0241

A*

ASX

C16

0241

B*Al

l AHR

I Mat

ches

TXV

onl

yTX

2N4A

3D

SXC

1603

61A

*A

SXC

1603

61B*

All A

HRI M

atch

esT

XV o

nly

TX3N

43

DSX

C16

0481

(A,B

)*A

SXC1

6048

1(A

,B)*

All A

HRI M

atch

esT

XV o

nly

TX5N

43

DSX

C16

0601

(A,B

)*A

SXC1

6060

1(A

,B)*

All A

HRI M

atch

esT

XV o

nly

TX5N

43

DSX

C18

0361

A*

ASX

C18

0361

A*Al

l AHR

I Mat

ches

TXV

onl

yTX

3N4

3D

SXC

1804

81A

*A

SXC

1804

81A*

All A

HRI M

atch

esT

XV o

nly

TX5N

43

DSX

C18

0601

A*

ASX

C18

0601

A*Al

l AHR

I Mat

ches

TXV

onl

yTX

5N4

3G

SC

1301

81(B

,D,F

)*Al

l AHR

I Mat

ches

0.05

5B

1789

855

1G

SC

1302

41(D

,E)*

All A

HRI M

atch

es0.

059

B17

8985

91

GSC

1302

41F*

All A

HRI M

atch

es0.

061

B17

8986

11

GS

C13

0301

E*Al

l AHR

I Mat

ches

0.06

5B

1789

865

1G

SC1

3036

1G*

All A

HRI M

atch

es0.

074

B17

8987

41

GS

C13

0363

B*Al

l AHR

I Mat

ches

0.07

4B

1789

874

1G

SC

1304

21B*

All A

HRI M

atch

es0.

084

B17

8988

41

GS

C13

0481

B*Al

l AHR

I Mat

ches

0.08

8B

1789

888

1G

SC

1304

83B*

All A

HRI M

atch

es0.

088

B17

8988

81

GS

C13

0484

A*Al

l AHR

I Mat

ches

0.08

2B

1789

882

1G

SC

1304

84B*

All A

HRI M

atch

es0.

088

B17

8988

81

GS

C13

0601

C*

All A

HRI M

atch

es0.

093

B17

8989

31

GS

C13

0603

B*Al

l AHR

I Mat

ches

0.09

3B

1789

893

1G

SC

1306

04B*

All A

HRI M

atch

es0.

093

B17

8989

31

GSZ

1301

81A*

VSZ1

3018

1A*

ASZ1

3018

1A*

WHP

4318

AA*

WG

HP4

318A

A*Al

l AHR

I Mat

ches

0.04

9B

1789

849

1G

SZ1

3024

1(A

,B)*

VSZ1

3024

1B*

ASZ1

3024

1A*

WH

P432

41A

*W

GH

P432

4AA*

All A

HRI M

atch

es0.

057

B17

8985

71

GSZ

1303

01A*

VSZ1

3030

1A*

ASZ1

3030

1A*

WH

P433

01A

*W

GH

P433

0AA*

All A

HRI M

atch

es0.

063

B17

8986

31

GSZ

1303

61B*

VSZ1

3036

1B*

All A

HRI M

atch

es0.

070

B17

8987

01

GSZ

1303

61A*

ASZ1

3036

1A*

WH

P433

61A

*W

GH

P433

6AA*

AR*F

3636

All

Oth

er A

HR

I Mat

ches

0.07

0

0.

068

B17

8987

0

B17

8986

82

1

GSZ

1303

63A*

AR*F

3636

All

Oth

er A

HR

I Mat

ches

0.07

0

0.

068

B17

8987

0

B17

8986

82

1

Out

door

Uni

tN

ote

Indo

or U

nit

Indo

or

Pist

on S

ize

Pist

on K

it P/

N

Page 112: Service Manual - R410a - RS6200006R32[1]

SERVICING

112

GS

Z130

421A

*V

SZ

1304

21A

*A

SZ1

3042

1A*

WH

P43

421A

*W

GH

P434

2AA

*Al

l AHR

I Mat

ches

0.07

4B

1789

874

1G

SZ1

3048

1A*

VS

Z13

0481

A*

AS

Z130

481A

*W

HP

4348

1A*

WG

HP4

348A

A*

All A

HRI M

atch

es0.

078

B17

8987

81

GS

Z130

483A

*Al

l AHR

I Mat

ches

0.07

8B

1789

878

1G

SZ1

3048

4A*

All A

HRI M

atch

es0.

078

B17

8987

81

GS

Z130

601A

*V

SZ

1306

01A

*A

SZ1

3060

1A*

WH

P43

601A

*W

GH

P436

0AA

*C

HP

F486

0D6D

*Al

l Oth

er A

HR

I Mat

ches

0.08

60.

088

B17

8988

6B

1789

888

1

GS

Z130

603A

*C

HP

F486

0D6D

*Al

l Oth

er A

HR

I Mat

ches

0.08

60.

088

B17

8988

6B

1789

888

1

GS

Z130

604A

*C

HP

F486

0D6D

*Al

l Oth

er A

HR

I Mat

ches

0.08

60.

088

B17

8988

6B

1789

888

1

GS

H13

0181

(B,C

)*Al

l AHR

I Mat

ches

0.05

5B

1789

855

1G

SH

1302

41(B

,C)*

All A

HRI M

atch

es0.

061

B17

8986

11

GS

H13

0301

(B,C

)*Al

l AHR

I Mat

ches

0.07

0B

1789

870

1G

SH

1303

61(B

,C)*

All A

HRI M

atch

es0.

073

B17

8987

31

GS

H13

0363

A*

All A

HRI M

atch

es0.

073

B17

8987

31

GS

H13

0421

A*

All A

HRI M

atch

es0.

082

B17

8988

21

GS

H13

0481

A*

All A

HRI M

atch

es0.

084

B17

8988

41

GS

H13

0483

A*

All A

HRI M

atch

es0.

084

B17

8988

41

GS

H13

0484

A*

All A

HRI M

atch

es0.

084

B17

8988

41

GS

H13

0601

A*

All A

HRI M

atch

es0.

093

B17

8989

31

GS

H13

0603

A*

All A

HRI M

atch

es0.

093

B17

8989

31

GS

H13

0604

A*

All A

HRI M

atch

es0.

093

B17

8989

31

GS

Z140

181A

*A

SZ1

4018

1A*

WHP

4418

AA

*W

GH

P441

8AA

*A

WU

F31

All A

HRI M

atch

es0.

051

TX

V on

lyB

1789

851

TX2N

4A2

3

GS

Z140

241A

*A

SZ1

4024

1A*

WHP

4424

AA

*W

GH

P442

4AA

*A

WU

F31

& 3

2Al

l AHR

I Mat

ches

0.05

7

T

XV

only

B17

8985

7 TX

2N4A

2

3

GS

Z140

301A

*A

SZ1

4030

1A*

WHP

4430

AA

*W

GH

P443

0AA

*A

WU

F31

& 3

2Al

l AHR

I Mat

ches

0.06

5

T

XV

only

B17

8986

5 TX

3N4

2

3G

SZ1

4036

1A*

WH

P443

6A(A

,B)*

All A

HRI M

atch

es0.

071

B17

8987

11

GS

Z140

421A

*W

HP44

42A

A*

All A

HRI M

atch

es0.

076

B17

8987

61

GS

Z140

481A

*W

HP44

48A

A*

All A

HRI M

atch

es0.

080

B17

8988

01

GS

Z140

601A

*W

HP44

60A

A*

All A

HRI M

atch

es0.

088

B17

8988

81

ASZ

1403

61(A

,B)*

WG

HP

4436

A(A

,B)*

All A

HRI M

atch

esT

XV

only

TX3N

43

AS

Z140

421A

*W

GH

P444

2AA

*Al

l AHR

I Mat

ches

TX

V on

lyTX

5N4

3A

SZ1

4048

1A*

WG

HP4

448A

A*

All A

HRI M

atch

esT

XV

only

TX5N

43

AS

Z140

601A

*W

GH

P446

0AA

*Al

l AHR

I Mat

ches

TX

V on

lyTX

5N4

3

Out

door

Uni

tN

ote

Indo

or U

nit

Indo

or

Pist

on S

izePi

ston

Kit

P/N

IT IS ESSEN

TIAL TH

AT IN

DOOR AND OUTD

OOR UNITS BE PR

OPE

RLY MATC

HED. F

AILURE TO FOLLOW THESE INSTRUCT

IONS OR TO 

PROPE

RLY MATC

H EVAPO

RATO

RS AND CONDEN

SERS CAN RESULT IN UNIT DAMAGE, PRO

PERT

Y DAMAGE AND/O

R PE

RSONAL INJURY. 

NO W

ARR

ANTY CLA

IM W

ILL BE HONORE

D FOR M

IX‐M

ATC

HED SYSTEMS TH

AT FA

IL TO ADHER

E TO THE SP

ECIFIED PISTO

N SIZE.

WA

RN

ING

(*)

SIG

NIF

IES

UN

IT R

EV

ISIO

N.

(1)

CO

RR

EC

T P

ISTO

N IS

SU

PP

LIE

D W

ITH

TH

E O

UTD

OO

R U

NIT

.(2

)C

OR

RE

CT

PIS

TON

IS S

UP

PLI

ED

IN T

HE

HIG

HE

ST

SA

LES

VO

LUM

E T

ES

TED

CO

MB

INAT

ION

IND

OO

RU

NIT

. FO

R A

LL O

THE

R IN

DO

OR

CO

MB

INAT

ION

S, P

ISTO

N M

US

T B

E P

UR

CH

AS

ED

FR

OM

DIS

TRIB

UTO

R.

(3)

TXV

MU

ST B

E PU

RC

HAS

ED S

EPAR

ATEL

Y.

PIST

ON

KIT

CH

AR

T

Page 113: Service Manual - R410a - RS6200006R32[1]

SERVICING

113

SSZ

1401

81A*

AW

UF3

1A

ll A

HR

I Mat

ches

0.05

1

T

XV

onl

yB1

7898

51

TX2N

4A2

3

SSZ

1402

41A*

AW

UF

31 &

32

All

Oth

er A

HR

I Mat

ches

0.05

7

T

XV

onl

yB1

7898

57

TX2N

4A2

3

SSZ

1403

01A*

AW

UF

31 &

32

All

Oth

er A

HR

I Mat

ches

0.06

5

T

XV

onl

yB1

7898

65

TX3N

42

3

SS

Z140

361(

A,B

)*A

ll A

HR

I Mat

ches

0.07

1B1

7898

711

SSZ

1404

21A*

All

AH

RI M

atch

es0.

076

B178

9876

1S

SZ14

0481

A*A

ll A

HR

I Mat

ches

0.08

2B1

7898

821

SSZ

1406

01A*

All

AH

RI M

atch

es0.

088

B178

9888

1S

SZ16

0241

A*A

ll A

HR

I Mat

ches

TX

V o

nly

TX2N

4A3

SSZ

1603

61A*

All

AH

RI M

atch

esT

XV

onl

yTX

3N4

3S

SZ16

0481

A*A

ll A

HR

I Mat

ches

TX

V o

nly

TX5N

43

SS

Z160

601(

A,B

)*A

ll A

HR

I Mat

ches

TX

V o

nly

TX5N

43

DSZ

C16

0241

A*

AS

ZC16

0241

A*

WG

HP4

624A

A*A

ll A

HR

I Mat

ches

TX

V o

nly

TX2N

4A3

DSZ

C16

0361

A*

AS

ZC16

0361

A*

WG

HP4

636A

A*A

ll A

HR

I Mat

ches

TX

V o

nly

TX3N

43

DSZ

C16

0481

A*

AS

ZC16

0481

A*

WG

HP4

648A

A*A

ll A

HR

I Mat

ches

TX

V o

nly

TX5N

43

DS

ZC16

0601

(A,B

)*A

SZC

1606

01(A

,B)*

WG

HP4

660A

B*A

ll A

HR

I Mat

ches

TX

V o

nly

TX5N

43

DSZ

C18

0361

A*

AS

ZC18

0361

A*

WG

HP4

836A

A*A

ll A

HR

I Mat

ches

TX

V o

nly

TX3N

43

DSZ

C18

0481

A*

AS

ZC18

0481

A*

WG

HP4

848A

A*A

ll A

HR

I Mat

ches

TX

V o

nly

TX5N

43

DS

ZC18

0601

(A,B

)*A

SZC

1806

01(A

,B)*

WG

HP4

860A

B*A

ll A

HR

I Mat

ches

TX

V o

nly

TX5N

43

CK

L36-

1P*

All

AH

RI M

atch

es0.

071

B178

9871

1C

KL4

9-1P

*A

ll A

HR

I Mat

ches

0.08

0B1

7898

801

CK

L60-

1P*

All

AH

RI M

atch

es0.

093

B178

9893

1C

K60

-3P

*A

ll A

HR

I Mat

ches

0.09

3B1

7898

931

CK

F36-

2P*

All

AH

RI M

atch

es0.

068

B178

9868

1C

KF3

6-5P

*A

ll A

HR

I Mat

ches

0.06

8B1

7898

681

CK

F48-

5P*

All

AH

RI M

atch

es0.

080

B178

9880

1C

KF6

0-5P

*A

ll A

HR

I Mat

ches

0.09

3B1

7898

931

CPR

F36-

2P*

All

AH

RI M

atch

es0.

073

B178

9873

1CP

RF3

6-5P

*A

ll A

HR

I Mat

ches

0.07

3B1

7898

731

CPR

F48-

5P*

All

AH

RI M

atch

es0.

084

B178

9884

1CP

KF

60-5

N*

All

AH

RI M

atch

es0.

093

B178

9893

1C

PK

F60-

5P*

All

AH

RI M

atch

es0.

093

B178

9893

1CP

KF

61-5

N*

All

AH

RI M

atch

es0.

093

B178

9893

1C

PK

F61-

5P*

All

AH

RI M

atch

es0.

093

B178

9893

1

Out

door

Uni

tN

ote

Indo

or U

nit

Indo

or

Pist

on S

ize

Pis

ton

Kit

P/N

IT IS ESSEN

TIAL TH

AT IN

DOOR AND OUTD

OOR UNITS BE PR

OPE

RLY MATC

HED. F

AILURE TO FOLLOW THESE INSTRUCT

IONS OR TO 

PROPE

RLY MATC

H EVAPO

RATO

RS AND CONDEN

SERS CAN RESULT IN UNIT DAMAGE, PRO

PERT

Y DAMAGE AND/O

R PE

RSONAL INJURY. 

NO W

ARR

ANTY CLA

IM W

ILL BE HONORE

D FOR M

IX‐M

ATC

HED SYSTEMS TH

AT FA

IL TO ADHER

E TO THE SP

ECIFIED PISTO

N SIZE.

WA

RN

ING

(*)

SIG

NIF

IES

UN

IT R

EV

ISIO

N.

(1)

CO

RR

EC

T P

ISTO

N IS

SU

PP

LIE

D W

ITH

TH

E O

UTD

OO

R U

NIT

.(2

)C

OR

RE

CT

PIS

TON

IS S

UP

PLI

ED

IN T

HE

HIG

HE

ST

SA

LES

VO

LUM

E T

ES

TED

CO

MB

INAT

ION

IND

OO

RU

NIT

. FO

R A

LL O

THE

R IN

DO

OR

CO

MB

INAT

ION

S, P

ISTO

N M

US

T B

E P

UR

CH

AS

ED

FR

OM

DIS

TRIB

UTO

R.

(3)

TXV

MU

ST B

E PU

RC

HAS

ED S

EPAR

ATEL

Y.

PIST

ON

KIT

CH

AR

T

Page 114: Service Manual - R410a - RS6200006R32[1]

SERVICING

114

S-105B THERMOSTATIC EXPANSION VALVEThe expansion valve is designed to control the rate of liquidrefrigerant flow into an evaporator coil in exact proportion tothe rate of evaporation of the refrigerant in the coil. Theamount of refrigerant entering the coil is regulated since thevalve responds to temperature of the refrigerant gas leavingthe coil (feeler bulb contact) and the pressure of the refrigerantin the coil. This regulation of the flow prevents the return ofliquid refrigerant to the compressor.The illustration below shows typical heatpump TXV/checkvalve operation in the heating and cooling modes.

COOLING HEATING

TXV VALVESSome TXV valves contain an internal check valve thuseliminating the need for an external check valve and bypassloop. The three forces which govern the operation of the valveare: (1) the pressure created in the power assembly by thefeeler bulb, (2) evaporator pressure, and (3) the equivalentpressure of the superheat spring in the valve.0% bleed type expansion valves are used on indoor andoutdoor coils. The 0% bleed valve will not allow the systempressures (High and Low side) to equalize during the shutdown period. The valve will shut off completely at approxi-mately 100 PSIG.30% bleed valves used on some other models will continueto allow some equalization even though the valve has shut-offcompletely because of the bleed holes within the valve. Thistype of valve should not be used as a replacement for a 0%bleed valve, due to the resulting drop in performance.The bulb must be securely fastened with two straps to a cleanstraight section of the suction line. Application of the bulb toa horizontal run of line is preferred. If a vertical installationcannot be avoided, the bulb must be mounted so that thecapillary tubing comes out at the top.THE VALVES PROVIDED BY GOODMAN ARE DESIGNEDTO MEET THE SPECIFICATION REQUIREMENTS FOROPTIMUM PRODUCT OPERATION. DO NOT USE SUB-STITUTES.

S-106 OVERFEEDINGOverfeeding by the expansion valve results in high suctionpressure, cold suction line, and possible liquid slugging of thecompressor.If these symptoms are observed:1. Check for an overcharged unit by referring to the cooling

performance charts in the servicing section.2. Check the operation of the power element in the valve as

explained in S-110 Checking Expansion Valve Operation.3. Check for restricted or plugged equalizer tube.

S-107 UNDERFEEDINGUnderfeeding by the expansion valve results in low systemcapacity and low suction pressures.If these symptoms are observed:1. Check for a restricted liquid line or drier. A restriction will

be indicated by a temperature drop across the drier.2. Check the operation of the power element of the valve as

described in S-110 Checking Expansion Valve Operation.

S-108 SUPERHEATThe expansion valves are factory adjusted to maintain 8 to 12degrees superheat of the suction gas. Before checking thesuperheat or replacing the valve, perform all the proceduresoutlined under Air Flow, Refrigerant Charge, Expansion Valve- Overfeeding, Underfeeding. These are the most commoncauses for evaporator malfunction.CHECKING SUPERHEATRefrigerant gas is considered superheated when its tempera-ture is higher than the saturation temperature correspondingto its pressure. The degree of superheat equals the degreesof temperature increase above the saturation temperature atexisting pressure. See Temperature - Pressure Chart onfollowing pages.

CAUTIONTo prevent personal injury, carefully connect anddisconnect manifold gauge hoses. Escaping liquidrefrigerant can cause burns. Do not vent refrigerantto atmosphere. Recover during system repairor final unit disposal.

1. Run system at least 10 minutes to allow pressure tostabilize.

2. For best results, temporarily install a thermometer on theliquid line at the liquid line service valve and 4-6" from thecompressor on the suction line. Ensure the thermometermakes adequate contact and is insulated for best pos-sible readings. Use liquid line temperature to determinesub-cooling and vapor temperature to determine super-heat.NOTE: An optional method is to locate the thermometerat the suction line service valve. Ensure the thermometermakes adequate contact and is insulated for bestpossible readings.

3. Refer to the superheat table provided for proper systemsuperheat. Add charge to lower superheat or recovercharge to raise superheat.

Superheat Formula = Suct. Line Temp. - Sat. Suct. Temp.

EXAMPLE:a. Suction Pressure = 143b. Corresponding Temp. °F. = 50c. Thermometer on Suction Line = 61°F.

Page 115: Service Manual - R410a - RS6200006R32[1]

SERVICING

115

PSIG °F PSIG °F PSIG °F PSIG °F PSIG °F PSIG °F12 -37.7 114.0 37.8 216.0 74.3 318.0 100.2 420.0 120.7 522.0 137.614 -34.7 116.0 38.7 218.0 74.9 320.0 100.7 422.0 121.0 524.0 137.916 -32.0 118.0 39.5 220.0 75.5 322.0 101.1 424.0 121.4 526.0 138.318 -29.4 120.0 40.5 222.0 76.1 324.0 101.6 426.0 121.7 528.0 138.620 -36.9 122.0 41.3 224.0 76.7 326.0 102.0 428.0 122.1 530.0 138.922 -24.5 124.0 42.2 226.0 77.2 328.0 102.4 430.0 122.5 532.0 139.224 -22.2 126.0 43.0 228.0 77.8 330.0 102.9 432.0 122.8 534.0 139.526 -20.0 128.0 43.8 230.0 78.4 332.0 103.3 434.0 123.2 536.0 139.828 -17.9 130.0 44.7 232.0 78.9 334.0 103.7 436.0 123.5 538.0 140.130 -15.8 132.0 45.5 234.0 79.5 336.0 104.2 438.0 123.9 540.0 140.432 -13.8 134.0 46.3 236.0 80.0 338.0 104.6 440.0 124.2 544.0 141.034 -11.9 136.0 47.1 238.0 80.6 340.0 105.1 442.0 124.6 548.0 141.636 -10.1 138.0 47.9 240.0 81.1 342.0 105.4 444.0 124.9 552.0 142.138 -8.3 140.0 48.7 242.0 81.6 344.0 105.8 446.0 125.3 556.0 142.740 -6.5 142.0 49.5 244.0 82.2 346.0 106.3 448.0 125.6 560.0 143.342 -4.5 144.0 50.3 246.0 82.7 348.0 106.6 450.0 126.0 564.0 143.944 -3.2 146.0 51.1 248.0 83.3 350.0 107.1 452.0 126.3 568.0 144.546 -1.6 148.0 51.8 250.0 83.8 352.0 107.5 454.0 126.6 572.0 145.048 0.0 150.0 52.5 252.0 84.3 354.0 107.9 456.0 127.0 576.0 145.650 1.5 152.0 53.3 254.0 84.8 356.0 108.3 458.0 127.3 580.0 146.252 3.0 154.0 54.0 256.0 85.4 358.0 108.8 460.0 127.7 584.0 146.754 4.5 156.0 54.8 258.0 85.9 360.0 109.2 462.0 128.0 588.0 147.356 5.9 158.0 55.5 260.0 86.4 362.0 109.6 464.0 128.3 592.0 147.958 7.3 160.0 56.2 262.0 86.9 364.0 110.0 466.0 128.7 596.0 148.460 8.6 162.0 57.0 264.0 87.4 366.0 110.4 468.0 129.0 600.0 149.062 10.0 164.0 57.7 266.0 87.9 368.0 110.8 470.0 129.3 604.0 149.564 11.3 166.0 58.4 268.0 88.4 370.0 111.2 472.0 129.7 608.0 150.166 12.6 168.0 59.0 270.0 88.9 372.0 111.6 474.0 130.0 612.0 150.668 13.8 170.0 59.8 272.0 89.4 374.0 112.0 476.0 130.3 616.0 151.270 15.1 172.0 60.5 274.0 89.9 376.0 112.4 478.0 130.7 620.0 151.772 16.3 174.0 61.1 276.0 90.4 378.0 112.6 480.0 131.0 624.0 152.374 17.5 176.0 61.8 278.0 90.9 380.0 113.1 482.0 131.3 628.0 152.876 18.7 178.0 62.5 280.0 91.4 382.0 113.5 484.0 131.6 632.0 153.478 19.8 180.0 63.1 282.0 91.9 384.0 113.9 486.0 132.0 636.0 153.980 21.0 182.0 63.8 284.0 92.4 386.0 114.3 488.0 132.3 640.0 154.582 22.1 184.0 64.5 286.0 92.8 388.0 114.7 490.0 132.6 644.0 155.084 23.2 186.0 65.1 288.0 93.3 390.0 115.0 492.0 132.9 648.0 155.586 24.3 188.0 65.8 290.0 93.8 392.0 115.5 494.0 133.3 652.0 156.188 25.4 190.0 66.4 292.0 94.3 394.0 115.8 496.0 133.6 656.0 156.690 26.4 192.0 67.0 294.0 94.8 396.0 116.2 498.0 133.9 660.0 157.192 27.4 194.0 67.7 296.0 95.2 398.0 116.6 500.0 134.0 664.0 157.794 28.5 196.0 68.3 298.0 95.7 400.0 117.0 502.0 134.5 668.0 158.296 29.5 198.0 68.9 300.0 96.2 402.0 117.3 504.0 134.8 672.0 158.798 30.5 200.0 69.5 302.0 96.6 404.0 117.7 506.0 135.2 676.0 159.2

100 31.2 202.0 70.1 304.0 97.1 406.0 118.1 508.0 135.5 680.0 159.8102 32.2 204.0 70.7 306.0 97.5 408.0 118.5 510.0 135.8 684.0 160.3104 33.2 206.0 71.4 308.0 98.0 410.0 118.8 512.0 136.1 688.0 160.8106 34.1 208.0 72.0 310.0 98.4 412.0 119.2 514.0 136.4 692.0 161.3108 35.1 210.0 72.6 312.0 98.9 414.0 119.6 516.0 136.7 696.0 161.8110 35.5 212.0 73.2 314.0 99.3 416.0 119.9 518.0 137.0112 36.9 214.0 73.8 316.0 99.7 418.0 120.3 520.0 137.3

*Based on ALLIED SIGNAL Data

Pressure vs. Temperature ChartR-410A

Page 116: Service Manual - R410a - RS6200006R32[1]

SERVICING

116

LIQUID PRESSURE AT SERVICE VALVE (PSIG) 8 10 12 14 16 18

189 58 56 54 52 50 48195 60 58 56 54 52 50202 62 60 58 56 54 52208 64 62 60 58 56 54215 66 64 62 60 58 56222 68 66 64 62 60 58229 70 68 66 64 62 60236 72 70 68 66 64 62243 74 72 70 68 66 64251 76 74 72 70 68 66259 78 76 74 72 70 68266 80 78 76 74 72 70274 82 80 78 76 74 72283 84 82 80 78 76 74291 86 84 82 80 78 76299 88 86 84 82 80 78308 90 88 86 84 82 80317 92 90 88 86 84 82326 94 92 90 88 86 84335 96 94 92 90 88 86345 98 96 94 92 90 88354 100 98 96 94 92 90364 102 100 98 96 94 92374 104 102 100 98 96 94384 106 104 102 100 98 96395 108 106 104 102 100 98406 110 108 106 104 102 100416 112 110 108 106 104 102427 114 112 110 108 106 104439 116 114 112 110 108 106450 118 116 114 112 110 108462 120 118 116 114 112 110474 122 120 118 116 114 112486 124 122 120 118 116 114499 126 124 122 120 118 116511 128 126 124 122 120 118

REQUIRED SUBCOOLING TEMPERATURE (°F) REQUIRED LIQUID LINE TEMPERATURE

Page 117: Service Manual - R410a - RS6200006R32[1]

SERVICING

117

To obtain the degrees temperature of superheat, subtract50.0 from 61.0°F.The difference is 11° Superheat. The 11° Superheat would fallin the ± range of allowable superheat.SUPERHEAT AND SUBCOOLING ADJUSTMENT ON TXVAPPLICATIONS

1. Run system at least 10 minutes to allow pressure tostabilize.

2. For best results, temporarily install a thermometer on theliquid line at the liquid line service valve and 4-6" from thecompressor on the suction line. Ensure the thermometermakes adequate contact and is insulated for best pos-sible readings. Use liquid line temperature to determinesub-cooling and vapor temperature to determine super-heat.NOTE: An optional method is to locate the thermometerat the suction line service valve. Ensure the thermometermakes adequate contact and is insulated for best pos-sible readings.

3. Check subcooling and superheat. Systems with TXVapplication should have a subcooling and superheat of7 ± 2ºF.a. If subcooling and superheat are low, adjust TXV

to 7 - 9ºF then check subcooling.b. If subcooling is low and superheat is high, add

charge to raise subcooling to 7 ± 2ºF then checksuperheat.

c. If subcooling and superheat are high, adjust TXVvalve to 7 ± 9ºF then check subcooling.

d. If subcooling is high and superheat is low, adjustTXV valve to 7 to 9ºF superheat and removecharge to lower the subcooling to 7 ± 2ºF.

The TXV should NOT be adjusted at light load conditions55º to 60ºF, under such conditions only the subcoolingcan be evaluated. This is because suction pressure isdependent on the indoor coil match, indoor airflow, andwet bulb temperature. NOTE: Do NOT adjust chargebased on suction pressure unless there is a grossundercharge.

4. Disconnect manifold set. Installation is complete.

S-109 CHECKING SUBCOOLINGRefrigerant liquid is considered subcooled when its tempera-ture is lower than the saturation temperature correspondingto its pressure. The degree of subcooling equals the degreesof temperature decrease below the saturation temperature atthe existing pressure.1. Attach an accurate thermometer or preferably a thermo-

couple type temperature tester to the liquid line as itleaves the condensing unit.

2. Install a high side pressure gauge on the high side (liquid)service valve at the front of the unit.

3. Record the gauge pressure and the temperature of theline.

4. Review the technical information manual or specificationsheet for the model being serviced to obtain the designsubcooling.

5. Compare the hi-pressure reading to the "Required LiquidLine Temperature" chart (page 108). Find the hi-pressurevalue on the left column. Follow that line right to thecolumn under the design subcooling value. Where the twointersect is the required liquid line temperature.Alternately you can convert the liquid line pressure gaugereading to temperature by finding the gauge reading inTemperature - Pressure Chart and reading to the left, findthe temperature in the °F. Column.

6. The difference between the thermometer reading andpressure to temperature conversion is the amount ofsubcooling.

Add charge to raise subcooling. Recover charge to lowersubcooling.Subcooling Formula = Sat. Liquid Temp. - Liquid LineTemp.EXAMPLE:

a. Liquid Line Pressure = 417b. Corresponding Temp. °F. = 120°c. Thermometer on Liquid line = 109°F.

To obtain the amount of subcooling subtract 109°F from120°F.The difference is 11° subcooling. See the specification sheetor technical information manual for the design subcoolingrange for your unit.

S-109A TWO SPEED APPLICATIONRun the remote on low stage cooling for 10 minutes untilrefrigerant pressures stabilize. Follow the guidelines andmethods below to check unit operation and ensure that therefrigerant charge is within limits. Charge the unit on lowstage.

1. Purge gauge lines. Connect service gauge manifold tobase-valve service ports. Run system at least 10 minutesto allow pressure to stabilize.

2. For best results, temporarily install a thermometer on theliquid line at the liquid line service valve and 4-6" from thecompressor on the suction line. Ensure the thermometermakes adequate contact and is insulated for best pos-sible readings. Use liquid line temperature to determinesub-cooling and vapor temperature to determine super-heat.NOTE: An optional method is to locate the thermometerat the suction line service valve. Ensure the thermometermakes adequate contact and is insulated for best pos-sible readings.

3. Check subcooling and superheat. Systems with TXVapplication should have a subcooling of 5 to 7 ºF andsuperheat of 7 to 9 ºF.

Page 118: Service Manual - R410a - RS6200006R32[1]

SERVICING

118

a. If subcooling and superheat are low, adjust TXV to7 to 9 ºF superheat, then check subcooling.NOTE: To adjust superheat, turn the valve stemclockwise to increase and counter clockwise todecrease.

b. If subcooling is low and superheat is high, addcharge to raise subcooling to 5 to 7 ºF then checksuperheat.

c. If subcooling and superheat are high, adjust TXVvalve to 7 to 9 ºF superheat, then check subcool-ing.

d. If subcooling is high and superheat is low, adjustTXV valve to 7 to 9 ºF superheat and removecharge to lower the subcooling to 5 to 7 ºF.

NOTE: Do NOT adjust the charge based on suctionpressure unless there is a gross undercharge.

4. Disconnect manifold set, installation is complete.Subcooling Formula = Sat. Liquid Temp. - Liquid Line Temp.

S-110 CHECKING EXPANSION VALVE OPERA-TION

1. Remove the remote bulb of the expansion valve from thesuction line.

2. Start the system and cool the bulb in a container of icewater, closing the valve. As you cool the bulb, the suctionpressure should fall and the suction temperature will rise.

3. Next warm the bulb in your hand. As you warm the bulb,the suction pressure should rise and the suction tempera-ture will fall.

4. If a temperature or pressure change is noticed, theexpansion valve is operating. If no change is noticed, thevalve is restricted, the power element is faulty, or theequalizer tube is plugged.

5. Capture the charge, replace the valve and drier, evacuateand recharge.

S-111 FIXED ORIFICE RESTRICTOR DEVICESThe fixed orifice restrictor device (flowrator) used in conjunc-tion with the indoor coil is a predetermined bore (I.D.).It is designed to control the rate of liquid refrigerant flow intoan evaporator coil.The amount of refrigerant that flows through the fixed orificerestrictor device is regulated by the pressure differencebetween the high and low sides of the system.In the cooling cycle when the outdoor air temperature rises,the high side condensing pressure rises. At the same time,the cooling load on the indoor coil increases, causing the lowside pressure to rise, but at a slower rate.Since the high side pressure rises faster when the tempera-ture increases, more refrigerant flows to the evaporator,increasing the cooling capacity of the system.When the outdoor temperature falls, the reverse takes place.

The condensing pressure falls, and the cooling loads on theindoor coil decreases, causing less refrigerant flow.A strainer is placed on the entering side of the tube to preventany foreign material from becoming lodged inside the fixedorifice restriction device.If a restriction should become evident, proceed as follows:1. Recover refrigerant charge.2. Remove the orifice or tube strainer assembly and re-

place.3. Replace liquid line drier, evacuate and recharge.

CHECKING EQUALIZATION TIMEDuring the "OFF" cycle, the high side pressure bleeds to thelow side through the fixed orifice restriction device. Checkequalization time as follows:1. Attach a gauge manifold to the suction and liquid line dill

valves.2. Start the system and allow the pressures to stabilize.3. Stop the system and check the time it takes for the high

and low pressure gauge readings to equalize.If it takes more than seven (7) minutes to equalize, therestrictor device is inoperative. Replace, install a liquid linedrier, evacuate and recharge.

S-112 CHECKING RESTRICTED LIQUID LINEWhen the system is operating, the liquid line is warm to thetouch. If the liquid line is restricted, a definite temperaturedrop will be noticed at the point of restriction. In severecases, frost will form at the restriction and extend down theline in the direction of the flow.Discharge and suction pressures will be low, giving theappearance of an undercharged unit. However, the unit willhave normal to high subcooling.Locate the restriction, replace the restricted part, replacedrier, evacuate and recharge.

S-113 OVERCHARGE OF REFRIGERANTAn overcharge of refrigerant is normally indicated by anexcessively high head pressure.An evaporator coil, using an expansion valve metering device,will basically modulate and control a flooded evaporator andprevent liquid return to the compressor.An evaporator coil, using a capillary tube metering device,could allow refrigerant to return to the compressor underextreme overcharge conditions. Also with a capillary tubemetering device, extreme cases of insufficient indoor air cancause icing of the indoor coil and liquid return to thecompressor, but the head pressure would be lower.There are other causes for high head pressure which may befound in the "Service Problem Analysis Guide."If other causes check out normal, an overcharge or a systemcontaining non-condensables would be indicated.If this system is observed:

Page 119: Service Manual - R410a - RS6200006R32[1]

SERVICING

119

1. Start the system.2. Remove and capture small quantities of gas from the

suction line dill valve until the head pressure is reducedto normal.

3. Observe the system while running a cooling performancetest. If a shortage of refrigerant is indicated, then thesystem contains non-condensables.

S-114 NON-CONDENSABLESIf non-condensables are suspected, shut down the systemand allow the pressures to equalize. Wait at least 15minutes. Compare the pressure to the temperature of thecoldest coil since this is where most of the refrigerant will be.If the pressure indicates a higher temperature than that of thecoil temperature, non-condensables are present.Non-condensables are removed from the system by firstremoving the refrigerant charge, replacing and/or installingliquid line drier, evacuating and recharging.

S-115 COMPRESSOR BURNOUTWhen a compressor burns out, high temperature developscausing the refrigerant, oil and motor insulation to decom-pose forming acids and sludge.If a compressor is suspected of being burned-out, attach arefrigerant hose to the liquid line dill valve and properly removeand dispose of the refrigerant.

NOTICEViolation of EPA regulations may result in finesor other penalties.

Now determine if a burn out has actually occurred. Confirmby analyzing an oil sample using a Sporlan Acid Test Kit, AK-3 or its equivalent.Remove the compressor and obtain an oil sample from thesuction stub. If the oil is not acidic, either a burnout has notoccurred or the burnout is so mild that a complete clean-upis not necessary.If acid level is unacceptable, the system must be cleaned byusing the clean-up drier method.

CAUTIONDo not allow the sludge or oil to contact the skin.Severe burns may result.

NOTE: The Flushing Method using R-11 refrigerant is nolonger approved by Amana® Brand Heating-Cooling.

Suction Line Drier Clean-Up MethodThe POE oils used with R410A refrigerant is an excellentsolvent. In the case of a burnout, the POE oils will remove anyburnout residue left in the system. If not captured by therefrigerant filter, they will collect in the compressor or othersystem components, causing a failure of the replacementcompressor and/or spread contaminants throughout thesystem, damaging additional components.Use AMANA® brand part number RF000127 suction line filterdrier kit. This drier should be installed as close to thecompressor suction fitting as possible. The filter must beaccessible and be rechecked for a pressure drop after thesystem has operated for a time. It may be necessary to usenew tubing and form as required.NOTE: At least twelve (12) inches of the suction lineimmediately out of the compressor stub must be discardeddue to burned residue and contaminates.1. Remove compressor discharge line strainer.2. Remove the liquid line drier and expansion valve.3 Purge all remaining components with dry nitrogen or

carbon dioxide until clean.4. Install new components including liquid line drier.5. Braze all joints, leak test, evacuate, and recharge sys-

tem.6. Start up the unit and record the pressure drop across the

drier.7. Continue to run the system for a minimum of twelve (12)

hours and recheck the pressure drop across the drier.Pressure drop should not exceed 6 PSIG.

8. Continue to run the system for several days, repeatedlychecking pressure drop across the suction line drier. Ifthe pressure drop never exceeds the 6 PSIG, the drier hastrapped the contaminants. Remove the suction line drierfrom the system.

9. If the pressure drop becomes greater, then it must bereplaced and steps 5 through 9 repeated until it does notexceed 6 PSIG.

NOTICE: Regardless, the cause for burnout must be deter-mined and corrected before the new compressor is started.

S-120 REFRIGERANT PIPINGThe piping of a refrigeration system is very important inrelation to system capacity, proper oil return to compressor,pumping rate of compressor and cooling performance of theevaporator.POE oils maintain a consistent viscosity over a large tem-perature range which aids in the oil return to the compressor;however, there will be some installations which require oilreturn traps. These installations should be avoided wheneverpossible, as adding oil traps to the refrigerant lines alsoincreases the opportunity for debris and moisture to beintroduced into the system. Avoid long running traps inhorizontal suction line.

Page 120: Service Manual - R410a - RS6200006R32[1]

SERVICING

120

LONG LINE SET APPLICATION R-410AThis long line set application guideline applies to all AHRIlisted R-410A air conditioner and heat pump split systemmatches of nominal capacity 18,000 to 60,000 Btuh. Thisguideline will cover installation requirements and additionalaccessories needed for split system installations where theline set exceeds 80 feet in actual length.

Accessories for lines greater than 80 feet:1. Crankcase Heater- a long line set application can

critically increase the charge level needed for a system.As a result, the system is very prone to refrigerantmigration during its off-cycle and a crankcase heater willhelp minimize this risk. A crankcase heater is required forany long line application (50 watt minimum).

2. For all line set applications over 80 feet a TXV is recom-mended. The subcooling should be 6º ± 2º.

3. Hard Start Assist- increased charge level in long lineapplications can require extra work from the compressorat start-up. A hard start assist device may be required toovercome this.

4. Liquid Line Solenoid - a long line set application cancritically increase the charge level needed for a system.As a result, the system is very prone to refrigerantmigration during its off-cycle and a liquid line solenoid willhelp minimize this. A liquid line solenoid is recom-mended for any long line application on straight coolingunits.

Tube Sizing:1. In long line applications, the “equivalent line length” is the

sum of the straight length portions of the suction line pluslosses (in equivalent length) from 45 and 90 degreebends. Select the proper suction tube size based onequivalent length of the suction line (see Tables 4 &5) and recalculated system capacity.

Equivalent length =Length horizontal

+ Length vertical

+ Losses from bends (see Tables 4 & 5)Example using ¾” elbow:

150 feet of straight tubing + (four short radius elbowsx 1.7) + (2 long radius elbows x 1.5) = 150 + 3.4 +3 =156.4 equivalent feet.

2. For any residential split system installed with a longline set, 3/8" liquid line size must be used. Limitingthe liquid line size to 3/8" is critical since an increasedrefrigerant charge level from having a larger liquid linecould possibly shorten a compressor’s life-span.

3. Single Stage Condensing Unit: The maximum lengthof tubing must not exceed 150 feet.

•80 feet is the maximum recommended vertical differencebetween the condenser and evaporator when the evapo-rator is above the condenser. Equivalent length is not toexceed 150 feet.

•The vertical difference between the condenser and evapo-rator when the evaporator is below the condenser canapproach 150 feet, as long as the equivalent length doesnot exceed 150 feet.

•The distance between the condenser and evaporator in acompletely horizontal installation in which the indoor andoutdoor unit do not differ more than 10 feet in verticaldistance from each other can approach 150 feet, as longas the equivalent length does not exceed 150 feet.

4. Two-Stage Condensing Unit: The maximum length oftubing must not exceed 80 feet where indoor coil islocated above the outdoor unit.

NOTE: When the outdoor unit is located above theindoor coil, the maximum vertical rise must not exceed25 feet. If the maximum vertical rise exceeds 25 feet,premature compressor failure will occur due to inad-equate oil return.5. Most refrigerant tubing kits are supplied with 3/8"-

thick insulation on the vapor line. For long lineinstallations over 80 feet that pass through a highambient temperature, ½”-thick suction line insula-tion is recommended to reduce loss of capacity.Insulate the liquid line if it passes through an areaof 120°F or greater. Do not attach the liquid line toany non-insulated portion of the suction line.

6. Vibration and Noise: In long line applications, refriger-ant tubing is highly prone to transmit noise and vibrationto the structure it is fastened to. Use adequate vibration-isolating hardware when mounting line set to adjacentstructure.

Table 4 lists multiplier values to recalculate system-coolingcapacity as a function of a system’s equivalent line length (ascalculated from the suction line) and the selected suctiontube size. Table 5 lists the equivalent length gained fromadding bends to the suction line. Properly size the suctionline to minimize capacity loss.

Page 121: Service Manual - R410a - RS6200006R32[1]

SERVICING

121

TABLE 4. CAPACITY MULTIPLIERS AS A FUNCTION OFSUCTION LINE SIZE & EQUIVALENT LENGTH

25 50 75 100 125 1501/2 0.99 0.97 0.96 0.94 0.94 0.935/8 1.00 0.99 0.99 0.99 0.98 0.983/4 1.00 1.00 1.00 1.00 0.99 0.99

5/8 0.99 0.99 0.98 0.98 0.97 0.973/4 1.00 1.00 0.99 0.99 0.99 0.997/8 1.00 1.00 1.00 1.00 0.99 0.99

5/8 0.99 0.99 0.98 0.97 0.96 0.963/4 1.00 1.00 0.99 0.99 0.99 0.987/8 1.00 1.00 1.00 1.00 1.00 0.99

5/8 0.99 0.98 0.96 0.95 0.94 0.933/4 1.00 1.00 0.99 0.99 0.98 0.987/8 1.00 1.00 1.00 1.00 0.99 0.99

1 1/8 1.00 1.00 1.00 1.00 1.00 1.00

3/4 1.00 0.99 0.99 0.98 0.97 0.977/8 1.00 1.00 0.99 0.99 0.99 0.99

1 1/8 1.00 1.00 1.00 1.00 1.00 1.00

3/4 0.99 0.99 0.98 0.97 0.96 0.967/8 1.00 0.99 0.99 0.99 0.98 0.98

1 1/8 1.00 1.00 1.00 1.00 1.00 1.00

3/4 0.99 0.98 0.97 0.96 0.94 0.937/8 1.00 0.99 0.98 0.98 0.97 0.97

1 1/8 1.00 1.00 1.00 0.99 0.99 0.99

UnitSuction

Dia (in)

42000

48000

60000

18000

24000

30000

36000

CapacityLength (ft)

NOTE: For a condenser with a liquid valve tube connectionless than 3/8" diameter, use 3/8" liquid line tubing for a lineset greater than 25 feet.

TABLE 5. LOSSES FROM SUCTION LINE ELBOWS(EQUIVALENT LENGTH, FT.)

3/4 7/8 1-1/8 90° short radius 1.7 2 2.3 90° long radius 1.5 1.7 1.6

45° 0.7 0.8 1

I.D. (in.) Type of elbow fitting

Installation Requirements1. In a completely horizontal installation with a long line set

where the evaporator is at the same altitude as (orslightly below) the condenser, the line set should besloped towards the evaporator. This helps reducerefrigerant migration to the condenser during a system’soff-cycle.

2. For a system installation where the evaporator is abovethe condenser, an inverted vapor line trap should beinstalled on the suction line just before the inlet to theevaporator (see Fig 6). The top of the inverted loop mustbe slightly above the top of the evaporator coil and canbe created simply by brazing two 90° long radius elbowstogether, if a bending tool is unavailable. Properlysupport and secure the inverted loop to the nearest pointon the indoor unit or adjacent structure.

Fig 6. Evaporator unit with inverted vapor loop

3. An oil trap is required at the evaporator if thecondenser is above the evaporator. Depending onthe vertical rise of the line set, oil traps are required in thesuction line. Oil traps should be installed at evaporator,in the suction line. Install one oil trap for a heightdifference of more than 15 feet between indoor andoutdoor units. Preformed oil traps are available at mostHVAC supply houses, or oil traps may be created bybrazing tubing elbows together (see diagram below).Remember to add the equivalent length from oil traps tothe equivalent length calculation of the suction line. Forexample, if you construct an oil trap using two 45°elbows, one short and one long 90° elbow in a ¾”diameter suction line, the additional equivalent lengthwould be 0.7+ 0.7+1.7+1.5, which equals 4.6 feet (referto Table 5).

Mounting the condensing unit above theevaporator coil will require an oil trap inthe suction line. Install one oil trap at theevaporator, for a height difference of more than15 feet between indoor and outdoor units.

Fig 7. Oil Trap Placement

Page 122: Service Manual - R410a - RS6200006R32[1]

SERVICING

122

Long Radius Street Ell

45°Street

Ell

45 °Ell

Short RadiusStreet Ell

Oil Trap Construction

Fig 8. Oil Trap

4. Low voltage wiring. Verify low voltage wiring size isadequate for the length used since it will be increasedin a long line application.

Initial System Charging

R-410A condensers are factory charged for 15 feet of line set.To calculate the amount of extra refrigerant (in ounces)needed for a line set over 15 feet, multiply the additional lengthof line set by 0.6 ounces. Note for the formula below, the linearfeet of line set is the actual length of liquid line (or suction line,since both should be equal) used, not the equivalent lengthcalculated for the suction line.

Use subcooling as the primary method for final systemcharging of long line set system application.

Extra refrigerant needed =(Linear feet of line set – 15 ft.) x X oz./ft.

Where X = 0.6 for 3/8" liquid tubing

Remember, 3/8" liquid tubing is required for all long lineset applications.

Heat pumps should be checked in both heating and coolingmode for proper charge level. This guideline is meant toprovide installation instructions based on most common longline set applications. Installation variables may affect systemoperation.

Follow the charging procedures in the outdoor unit I/O manualto ensure proper superheat and sub-cooling levels, especiallyon a system with a TXV installed in the indoor unit. Heatpumps should be checked in both heating and cooling modefor proper charge level. This guideline is meant to provideinstallation instructions based on most common long line setapplications. Installation variables may affect systemoperation.

NO ADDITIONAL COMPRESSOR OIL IS NEEDED FORLONG LINE SET APPLICATIONS ON RESIDENTIAL SPLITSYSTEMS.

S-202 DUCT STATIC PRESSURES AND/OR STATICPRESSURE DROP ACROSS COILS

This minimum and maximum allowable duct static pressurefor the indoor sections are found in the specifications section.Tables are also provided for each coil, listing quantity of air(CFM) versus static pressure drop across the coil.Too great an external static pressure will result in insufficientair that can cause icing of the coil. Too much air can causepoor humidity control and condensate to be pulled off theevaporator coil causing condensate leakage. Too much aircan also cause motor overloading and in many cases thisconstitutes a poorly designed system.

Page 123: Service Manual - R410a - RS6200006R32[1]

SERVICING

123

S-203 AIR HANDLER EXTERNAL STATICTo determine proper air movement, proceed as follows:1. Using a draft gauge (inclined manometer), measure the

static pressure of the return duct at the inlet of the unit,(Negative Pressure).

2. Measure the static pressure of the supply duct, (PositivePressure).

3. Add the two readings together.

TOTAL EXTERNAL STATIC

NOTE: Both readings may be taken simultaneously and readdirectly on the manometer if so desired.4. Consult proper table for quantity of air.

If external static pressure is being measured on a furnace todetermine airflow, supply static must be taken between the"A" coil and the furnace.

Air Flow

TOTAL EXTERNAL STATIC

S-204 COIL STATIC PRESSURE DROP1. Using a draft gauge (inclined manometer), connect the

positive probe underneath the coil and the negative probeabove the coil.

2. A direct reading can be taken of the static pressure dropacross the coil.

3. Consult proper table for quantity of air.

STATIC PRESSURE DROP

If the total external static pressure and/or static pressure dropexceeds the maximum or minimum allowable statics, checkfor closed dampers, dirty filters, undersized or poorly laid outduct work.

Page 124: Service Manual - R410a - RS6200006R32[1]

124

ACCESSORIES WIRING DIAGRAMSHIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

+5VDC

24VAC

G

POWER SUPPLYINPUT

POWER SUPPLY COMMONOUT TO HP CONTROL

P3-1

6.8K

P3-7

Y-HP

P1-6

P1-4

COMPRESSOR OUTPUT

P1-7

O

POWER SUPPLY OUTTO THERMOSTAT

24VAC

Q2

K3

W1

POWER SUPPLY INPUT(COMMON)

+VDC

E/W1

Y

P2-8

CALL FORREVERSING VALVE

P3-5

C

C

BLOWER FAN DEMANDOUTPUT

P3-3

P1-8

Y-STATY-FURN

C

P3-2

P1-1

P3-8

REVERSING VALVEOUTPUT

BREAK FOR ODT

FURNACE DEMANDOUTPUT

P1-3

R

24VAC

K4

HP CALL FOR FURNACE(DURING DEFROST)

W2

Y2-STATY2-FURN

CALL FORCOMPRESSOR

P2-7

P3-6

+VDC

Y2

O

REVERSINGVALVE OUTPUT

Q1

Y

P2-4

K1

OT-NO

Y

P2-9

CALL FOR 2ND STAGECOMPRESSOR

Y2

1.0K

G-FURN

P2-1

C

OT-C

C

SECOND STAGECOMPRESSOR OUTPUT

G

CALL FOREMERGENCY HEAT

W1-FURNW2-HP

F1 3A

OT-NC

24VAC

2ND STAGE COMPRESSORDEMAND OUTPUT

W1

CALL FORFURNACE HEAT

6.8K

G-STAT

+VDC

P3-4

FURNACE

P2-6

K2

ODT (OUTDOORTHERMOSTAT)

Y

R

SECOND STAGE FURNACEDEMAND OUTPUT

MICROPROCESSOR

Y2-HP

P1-5

CALL FOR 2ND STAGEFURNACE HEAT

O

W2

CALL FORBLOWER FAN

THERMOSTAT

P2-5

12

R

Y2

POWERSUPPLY

COMPRESSORCONTACTOR OUTPUT

O

HEAT

PUMP

P2-3

+5VDC

W2

P3-9

P2-2

E

POWER SUPPLY COMMONOUT TO THERMOSTAT

POWER SUPPLY OUTTO HP CONTROL

C

P1-2

ALL FUEL SYSTEM AFE18-60A CONTROL BOARD

ALL FUEL CONTROL BOARD - AFE18-60AThis wiring diagram is for reference only. Not all wiring is as shown above.

Refer to the appropriate wiring diagram for the unit being serviced.(For use with Heat Pumps in conjunction with 80% or 90% Single-Stage or Two-Stage Furnaces)

Page 125: Service Manual - R410a - RS6200006R32[1]

ACCESSORIES WIRING DIAGRAMS

125

HIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

EMERGENCYHEAT

RELAY

13

42

BLUE

WHITE

BLACK

BROWN

THERMOSTAT

OT/EHR18-60

21

From Air Handler

C G W2 R

C R W2 O Y

From Outdoor Unit

C

G

W2

E

R

O

Y

Indo

or T

herm

osta

t

BLUE

GREEN

WHITERED

BLUERED

WHITE

ORANGE

YELLOW

10kw and Below, One Stage Electric Heat

RED

EMERGENCYHEAT

RELAY

1 42

BLUE

WHITE

BLACK

BROWN

THERMOSTAT

OT/EHR18-60

21

From Air Handler

C G W2 R

C R W2 O Y

From Outdoor Unit

C

G

W2

E

R

O

Y

Indo

or T

herm

osta

t

W3BLU

E

GREEN

WHITE

REDBROW

N

BLUERED

WHITE

ORANGE

YELLOW

15kw and Above, Two Stage Electric Heat

3

RED

SEE NOTE

Note:When using a Thermostat with only onestage for electric heat (W2), tie white andbrown wires from air handler together.

Typical Wiring Schematics for OT/EHR18-60 (Outdoor Thermostat & Emergency Heat Relay).This wiring diagram is for reference only. Not all wiring is as shown above.

Refer to the appropriate wiring diagram for the unit being serviced.

Page 126: Service Manual - R410a - RS6200006R32[1]

126

ACCESSORIES WIRING DIAGRAMSHIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

EMERGENCYHEAT

RELAY

13

42

BLUE

WHITE

BLACK

BROWN

THERMOSTAT

OT/EHR18-60 #2

21

From Air Handler

C G W2 R

C R W2 O Y

From Outdoor Unit

C

G

W2

E

R

O

Y

Indo

or T

herm

osta

t

W3

W3

BLUE

GREEN

WHITERED

BROWN

BLUERED

WHITE

ORANGE

YELLOW

15kw and Above with Two OT/EHR18-60's, Two Stage Electric Heat and Two Stage Thermostat

HEATRELAY

EMERGENCY THERMOSTAT

1 4

3 2

12

BROWN

BLACK

WHITE

BLUE

OT/EHR18-60 #1

RED

RED

Typical Wiring Schematics for OT/EHR18-60 (Outdoor Thermostat & Emergency Heat Relay).This wiring diagram is for reference only. Not all wiring is as shown above.

Refer to the appropriate wiring diagram for the unit being serviced.

Page 127: Service Manual - R410a - RS6200006R32[1]

ACCESSORIES WIRING DIAGRAMS

127

HIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

BK

BL

BK

L1 L2

BK

BK

HTR1TLHTR2

RD

9

8

7

R

WH

BLPU

TL

BK

5

6

3

4

BK

RD

1

2

WH

BK

L2L1

BK

RD

RD

RD

BK

R

HTR1 TL

L1

BK

6

8

9

7

2

RDPU

4

5

3

BK

RD

1

BK

L2 L1 L2

RD

YL

M1

M2

BK

RD

YL

RD

R1M4

RDBK

M3

HTR3 TL

HTR2

HTR1 TL

TL

PU

M2

R2

YL

M1

BL

WH

BR

BLRD

BK

RD

BK

TLHTR1

BK

HTR4

HTR3

HTR2

BKRD

9

7

8

L2L1 L1 L2

2

5

6

3

4

1

RD

M1YL

BK

M2

BL

WH 6

BL

RDBK

YL8

9

7

M6

M5M3

R1

M4

RDPU

M7

R2

M8

BL

TL

TL

TL

YL

BL

RD

BK

RDBL

BR

4

5

3

2

BK 1

ONE (1) ELEMENT ROWS TWO (2) ELEMENT ROWS THREE (3) ELEMENT ROWS FOUR (4) ELEMENT ROWS

FL

M1

M2

FL

FL

M1

M2

M3

M4

FL

FL

FL

FL

FL

FL

FL

USE COPPER OR ALUMINUM WIRE

SPEEDUP

COPPER OR ALUMINUMPOWER SUPPLY

(SEE RATING PLATE)USE MIN. 75°C FIELD WIRE

EQUIPMENT GROUND

BL BL

NOTE3

SEERD

M1

BR

BRRC

EM

RD

BL

RD

BK

PU

WH

EBTDR

SR

BL

G

RDXFMR-RXFMR-C

C

R

RDGR

2NOTESEE

BL RD GR WH BR

5

NO

COM

NC

K1

K1

PU

PU

BK

RDC

BK

BR

PLF

BK

1

RD PU

2 3

240

24V 4

1 2 3

TR

RD

SEENOTE

BL BR

4 5

WH

6 7

4

8 9

PLM

GRD

1

BK

2 3

RD

L2L1

4 5 6 7 8 9

0140M00037

4) Brown and white wires are used with Heat Kits only.

PLMPLFTR

FACTORY WIRING

FIELD WIRING

1) Red wires to be on transformer terminal "3" for 240 volts and on terminal "2" for 208 volts.2) See composite wiring diagrams in installation instructions

for proper low voltage wiring connections.

Notes:DELAY RELAY

STRAIN RELIEF

EVAPORATOR MOTOR

ELECTRONIC BLOWER TIME

RUN CAPACITORSR

EM

EBTDR

RC

BKRD

BLYL

BLUE

BLACKREDYELLOW

COMPONENT CODE

BROWNPURPLEGREEN

PUBR

GR

FEMALE PLUG CONNECTORMALE PLUG CONNECTOR

NOTE 2

TRANSFORMER

HIGH VOLTAGE LOW VOLTAGE

HIGH VOLTAGE LOW VOLTAGE

PLF3 2

COLOR CODE

RD

TR

WH

6

BR

5 PLF4

4 24V 5

SEE NOTE 11 2 3

RC

LO

EM

GR

WIRING CODE

BL

EBTDR

HI COM

NCM1

EBTDR

NO

208/240 VOLTS

1

1

PLF

PLM

L1

PLM 2

L2

(M2)

PU

RC

(COM) BK

BL MEDIUM

3 SPEEDBR

HIGH

EM

(M1) RD LOW

IF REPLACEMENT OF THE ORIGINAL WIRESSUPPLIED WITH THIS ASSEMBLY IS NECESSARY,USE WIRE THAT CONFORMS TO THENATIONAL ELECTRIC CODE.

M2

PU

(TR 1)

M2

R GCEBTDR

SEE NOTE 1

5)

FL FUSE LINKTL THERMAL LIMIT

HTR HEAT ELEMENTS

SEE NOTE 5

R RELAY

TERMINAL BLOCK SHOWNFOR 50HZ MODELS ONLY

THREE SPEED MOTOR WIRING(SELECT MODELS ONLY)

SEE NOTE 3

EBTDR has a 7 second on delay when "G" is energized and a 65 second offdelay when "G" is de-energized.

3) Confirm speed tap selected is appropriate for application. If speed tap needsto be changed, connect appropriate motor wire (Red for low, Blue for medium,and Black for high speed) on "COM" connection of the EBTDR.Inactive motor wires should be connected to "M1 or M2" on EBTDR.

MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE.

NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEAT ER

WHITEWH

Typical Wiring Schematic ADPF, ARPF, ARUF with Electric Heat.This wiring diagram is for reference only. Not all wiring is as shown above.

Refer to the appropriate wiring diagram for the unit being serviced.

COPPER

EQUIPMENT GROUNDUSE COPPER WIRE

Page 128: Service Manual - R410a - RS6200006R32[1]

128

ACCESSORIES WIRING DIAGRAMSHIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

COMXFMR-CXFMR-R

SPEEDUP

CNC

M1

K1

R

G

NOK1

USE COPPER OR ALUMINUM WIREEQUIPMENT GROUND

3 5

2

1 4

TR

PC

PU

L1 L2

BLW BR

SR

PKG

W

BR

BL

PU

R

BK

R

R

R

BK

BLBL

R

208/240 24V

BL

R

M6

M5RS2

W

BR

BL

BL

L1 L2

BK

BK

R

R

Y

Y

Y

M8

M7

BL

BL

BL

EBTDR

HTR2

FL HTR3 TL

FL HTR4 TL

8

9

7

6

5

4

3

1

2

Typical Wiring Schematic MBR Blower with Electric Heat.This wiring diagram is for reference only. Not all wiring is as shown above.

Refer to the appropriate wiring diagram for the unit being serviced.

USE COPPER WIRE

Page 129: Service Manual - R410a - RS6200006R32[1]

ACCESSORIES WIRING DIAGRAMS

129

HIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

NO

MARK

INDICATES

NO

HEAT KIT INSTALLED

AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE.MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED

BK

BK

BL

IF REPLAC EM ENT OF THE ORIGINAL W IR ES SU PPLIED W ITH THIS ASSEM BLY IS N EC ESSAR Y, U SE 105°C . W IRE. SIZE TO CONFO RM T O T HE NATIONA L ELECTRI C C ODE.

FIELD CON NEC TION

* SEE NOTE 7LOW VOLTAGE

DS1

C OPPER

(SEE RATIN G PLATE)POW ER SUPPLY

C ONTR OLS SHOW N WITH U TILIT IES IN "ON" POSITION AND TH ERM OSTAT IN "O FF" POSIT ION .

PN. B1368270 RE

V. A

J1

BOX

THER

MO

STATS

W2

HEA

TER

W CR

J3J2

BR

RBL

Y/Y2

24 VAC

Y1

RPU

HUM

IDIS

TAT

HU

MR

Y1

G

YG

U SE COPPER W IR EEQUIPM EN T GRO UN D

RBL

WBR

W 1TH ERM OSTAT

YC

ON

CON

DENS

ER

COM

W2

OE

DW

1

OU

TDO

OR

HE

ATPUM

P

W/W

2

R

W

BLO

TCO

T1C

OT2

OE\W

1

BR

BLY

BLY

YCO N

TOC ONDEN SER

C

PL2 31 2

BR

BK

PL1PUW BL

BR RY

G

Y1CW 2 R

TO

Y/Y2G

1

R

2 3

BK

L1 L2

BK

BK

HTR1TLHTR2

R

9

8

7

R

W

BLPU

TL

BK

5

6

3

4

BK

R

1

2

W

BK

L2L1

BK

R

R

R

BK

R

HTR1 TL

0140A00000P

EM

2

24 VOLT

O

SEE NOT E 2

C OLOR C ODE

PRO GRAM JU MPER

7. SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGECONNECTIONS AND DETAILS ON COMPATIBLE THERMOSTATS AND THEIR CONNECTIONS.

3. FOR OUTDOOR THERMOSTAT OPERATION OF SECOND STAGE HEAT, CUT PJ2 & ADD OT18-60 TO OTC & OT2.2. FOR TWO STAGE ELECTRIC HEAT APPLICATIONS CUT PJ4. (USE ONLY ON 15 & 20 KW MODELS).

4. FOR SINGLE STAGE COOLING APPLICATIONS CONNECT THERMOSTAT TO Y/Y2 ONLY, TAPE OR REMOVE Y1 CONNECTION. CONNECT CONDENSING UNIT TO YCON & C.

6. RED WIRES TO BE ON TRANSFORMER TERMINAL 3 FOR 240 VOLTS AND ON TERMINAL 2 FOR 208 VOLTS.

1. FOR HEAT PUMP APPLICATIONS REMOVE ORANGE JUMPER WIRE BETWEEN O & Y1.

EVAPORATOR M OTOR

5. WHEN HUMIDSTAT IS PROVIDED CUT PJ6. THERMOSTAT OPENS ON HUMIDITY RISE.

NOTES:

EM

BK

R

G

PJ2,PJ 4,PJ6

SEE N OTE 3

BLAC KBK

PLEM

YR

BL

PLUG

R EDYELLOWBLUE

W W HITE

BL

4 5 6 7 8 9

W

R

R

BL

C OM3

BL

5

TR240

2208

1

24V

4

R

4 5 67 8 9

SEE N OTE 5

HUMR

PJ6

2OT

1OT

PJ2

W 2

OTC

5 PL2

TR

4

PL2 2

1

PL1 2

FAC TORY W IRIN G

WIRIN G COD E

FIELD W IRIN G

HIGH VOLTAGE LOW VO LTAGE

HIGH VOLTAGE LOW VO LTAGE

TER MINAL BOARDVAR IABLE SPEED TR ANSF ORMERVSTB T R

C OMPON ENT C ODE

PU PUR PLE

PIN KORANGEBROW NBR

PK0

GR EENG

SEE N OTE 1

N OTE DIOD EON VSTB

*SEE N OTE 7

W 1

W 1

6

W 2W E

PJ4

5

DIODEIN4005

Y1 Y Y2

YCO N

PL2

208/240 VOLTS

3

TO LOW VOLTAGETER MINAL BOARD

G C

N OTE 4SEE

4 PL2

1 PL2

1 PL1

L1

BK

6

8

9

7

2

RPU

4

5

3

BK

R

1

BK

L2 L1 L2

R

Y

M1

M2

BK

R

Y

R

R1M4

RBK

M3

HTR3 TL

HTR2

HTR1 TL

TL

PU

M2

R2

Y

M1

BL

W

BR

BLR

BK

R

BK

TLHTR1

BK

HTR4

HTR3

HTR2

BKR

9

7

8

L2L1 L1 L2

2

5

6

3

4

1

R

M1Y

BK

M2

BL

W 6

BL

RBK

Y8

9

7

M6

M5M3

R1

M4

RPU

M7

R2

M8

BL

TL

TL

TL

Y

BL

R

BK

RBL

BR

4

5

3

2

BK 1

OT2

HUM

W1

OT1

W2

PJ2

PJ6

PJ4

SEE N OTE 8

8. DISCARD ORIGINAL "PL1" PLUG CONNECTOR WHEN INSTALLING OPTIONAL HEAT KIT.

R ELAY

TH ERM AL LIMIT

RH EAT ELEMEN TH TR

TL

ONE (1) ELEMENT ROWS TWO (2) ELEMENT ROWS THREE (3) ELEMENT ROWS FOUR (4) ELEMENT ROWS

OW 2

BRO

OBR

R

R

O

O

FL FU SE LI NK

FL

M1

M2

FL

FL

M1

M2

M3

M4

FL

FL

FL

FL

FL

FL

FL

Typical Wiring Schematic AEPF with Electric Heat.This wiring diagram is for reference only. Not all wiring is as shown above.

Refer to the appropriate wiring diagram for the unit being serviced.

Page 130: Service Manual - R410a - RS6200006R32[1]

130

ACCESSORIES WIRING DIAGRAMSHIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

Blower Section

COM

OUTDOOR

TOTO

OT2

OT1

PJ2

PJ6

PJ4

HKR Heat Kit

Typical Wiring Schematic MBE Blower with Electric Heat.This wiring diagram is for reference only.

Not all wiring is as shown above.Refer to the appropriate wiring diagram for the unit being serviced.

Page 131: Service Manual - R410a - RS6200006R32[1]

ACCESSORIES WIRING DIAGRAMS

131

HIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

Typical Wiring Schematic ASPF with Electric Heat.This wiring diagram is for reference only. Not all wiring is as shown above.

Refer to the appropriate wiring diagram for the unit being serviced.

BK

BL

BK

L1 L2

BK

BK

HTR1TLHTR2

RD

9

8

7

R

WH

BLPU

TL

BK

5

6

3

4

BK

RD

1

2

WH

BK

L2L1

BK

RD

RD

RD

BK

R

HTR1 TL

L1

BK

6

8

9

7

2

RDPU

4

5

3

BK

RD

1

BK

L2 L1 L2

RD

YL

M1

M2

BK

RD

YL

RD

R1M4

RDBK

M3

HTR3 TL

HTR2

HTR1 TL

TL

PU

M2

R2

YL

M1

BL

WH

BR

BLRD

BK

RD

BK

TLHTR1

BK

HTR4

HTR3

HTR2

BKRD

9

7

8

L2L1 L1 L2

2

5

6

3

4

1

RD

M1YL

BK

M2

BL

WH 6

BL

RDBK

YL8

9

7

M6

M5M3

R1

M4

RDPU

M7

R2M8

BL

TL

TL

TL

YL

BL

RD

BK

RDBL

BR

4

5

3

2

BK 1

ONE (1) ELEMENT ROWS TWO (2) ELEMENT ROWS THREE (3) ELEMENT ROWS FOUR (4) ELEMENT ROWS

FL

M1

M2

FL

FL

M1

M2

M3

M4

FL

FL

FL

FL

FL

FL

FL

USE COPPER OR ALUMINUM WIRE

COPPER OR ALUMINUMPOWER SUPPLY

(SEE RATING PLATE)USE MIN. 75°C FIELD WIRE

EQUIPMENT GROUND

BL

EM

RD

BL

5

BK

C

BK

PLF

BK

1

RD

2 3

240

24V 4

1 2 3

TR

RD

SEENOTE 4

BL BR

4 5

WH

6 7 89

PLM

GRD

1

BK

2 3

RD

L2L1

4 5 6 7 8 9

0140A00034

4) Brown and white wires are used with Heat Kits only.

PLMPLFTR

FACTORY WIRING

FIELD WIRING

1) Red wires to be on transformer terminal "3" for 240 volts and on terminal "2" for 208 volts.2) See composite wiring diagrams in installation instructions

for proper low voltage wiring connections.

Notes:DELAY RELAY

RELAY

EVAPORATOR MOTOR

ELECTRONIC BLOWER TIME

TERMINAL BOARD R

EM

EBTDR

TB

BKRD

BLYL

BLUE

BLACKREDYELLOW

COMPONENT CODE

BROWNPURPLEGREEN

PUBR

GR

FEMALE PLUG CONNECTORMALE PLUG CONNECTOR

TRANSFORMER

HIGH VOLTAGE LOW VOLTAGE

HIGH VOLTAGE LOW VOLTAGE

PLF 2

COLOR CODE

TR

6 5 PLF4

4 24V 5

SEE NOTE 11 2 3

EM

WIRING CODE

208/240 VOLTS

1

1

PLF

PLM

L1

PLM 2

L2

IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NEC ESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE.

SEE NOTE 1

FL FUSE LINKTL THERMAL LIMIT

HTR HEAT ELEMENTS

CR CONTROL RELAY

TERMINAL BLOCK SHOWNFOR 50HZ MODELS ONLY

3) Confirm speed tap selected is appropriate for application. If speed tap needs to be changed, connect red wire from terminal 4 of CR relay to appropriate tapat TB

MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE.

NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEAT ER

WHITEWH

A B

17

4

CR

R C G W1 W2 Y2Y1 O

SEE NOTE 2

21 43 5

NC GL

41 32 5DH

XFMR-C

C

R

EBTDR

XFMR-R

RD

RD

BL

BL

BL

BL

BR

WH

BL

RD

RDCOM

NO NCG GR

RD

RD

BL

GR

GR

RD

RD

RD

BL

BKRD

SEENOTE 3

C L G N

W2R W1C G 4Y1 OY2 1DH 32 5

B A

NO NCG

C

XFMR-C

COM

EBTDR

XFMR-RR

1

C

EM2

43

5

7 4CR

EQUIPMENT GROUNDUSE COPPER WIRE

COPPER