8/14/2019 Sensor Break Out Cable Instructions http://slidepdf.com/reader/full/sensor-break-out-cable-instructions 1/12 How To Use Sensor Break-Out Cable --To Check ECPG Pressure Sensor Sensor Breakout cable P.No.3824775 ( FOR PRESSURE SENSORS ) Purpose: To check whether the sensor is functioning while the engine is running. •Disconnect the connector(1) from the Engine wiring harness going to the sensor. •Connect this disconnected connector(1) to the shroud(2) as shown below. •Connect the connector(3) of the sensor breakout cable to the sensor (4). •Pressure Sensors work on 0-5 volts dc. Check the voltage between the red & black wires of the sensor breakout red & black terminals. This should be in the range of 4.5 vdc to 5 vdc.If the voltage is within the specified range then the controller supplying this voltage is OK. Check the voltage between black & yellow terminals this should be in the range of 0-4.5vdc as per the pressure on the engine. (refer to the pressure sensor table for exact values of voltages Vs Pressure Multimeter PowerSource for sensor ( 4.5 TO 5 VDC) Voltage signal from sensor Use Digital Multimeter to check voltages From Engine Harness Pressure Sensor mounted on the engine Shroud 1 2 3 4 Part No.3408496
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
How To Use Sensor Break-Out Cable --To Check ECPG Pressure Sensor
Sensor Breakout cable P.No.3824775 ( FOR PRESSURE SENSORS )
Purpose: To check whether the sensor is functioning while the engine is running.•Disconnect the connector(1) from the Engine wiring harness going to the sensor.
•Connect this disconnected connector(1) to the shroud(2) as shown below.
•Connect the connector(3) of the sensor breakout cable to the sensor (4).
•Pressure Sensors work on 0-5 volts dc. Check the voltage between the red & black wires of
the sensor breakout red & black terminals. This should be in the range of 4.5 vdc to 5 vdc.If
the voltage is within the specified range then the controller supplying this voltage is OK.Check the voltage between black & yellow terminals this should be in the range of 0-4.5vdc as
per the pressure on the engine. (refer to the pressure sensor table for exact values of voltages
Vs Pressure
Multimeter
PowerSource
for sensor ( 4.5 TO 5 VDC)Voltage signalfrom sensor
How To Use Sensor Break-Out Cable --PCC Pressure Sensor
Purpose: To check whether the sensor is functioning while the engine is running.
•Disconnect the connector(1) from the Engine wiring harness going to the sensor.
•Connect this disconnected connector(1) to the shroud(2) as shown below.
•Connect the connector(3) of the sensor breakout cable to the sensor(4).
•Pressure Sensors work on 0-5 volts dc. Check the voltage between the red & black wires of the sensor breakout red & black terminals. This should be in the range of 4.5 vdc to 5 vdc.If
the voltage is within the specified range then the controller supplying this voltage is OK.
Check the voltage between black & yellow terminals this should be in the range of 0-4.5vdc as
per the pressure on the engine. (refer to the pressure sensor table for exact values of voltages
Vs Pressure)
Multimeter
PowerSource
for sensor ( 0 TO 5 VDC between red & black terminals)
How To Use Sensor Break-Out Cable -- To Check ECPG Actuator Voltage
Purpose: To check whether the ECPG is giving supply to Actuator when the engineis running.•Disconnect the connector(1) from the Engine wiring harness going to the Actuator.
•Connect this disconnected connector(1) to the shroud (2) as shown below.
•Connect the connector(3) of the sensor breakout cable to the Actuator(4)
Check the voltage between Red & Blue terminals. This should be in the range of 0-4.5vdc asper the Load on the engine.