Anixter Cenelec Nominal Conductor Insulation Max Approx Min BendingPart No. Code Conductor Class Thickness O/D Weight Radius
Area (fixed bend)mm2 mm mm kg/km mm
A3-A01-0015 H07V-U1 1.5 1 0.7 3.2 21 10
A3-A07-0015 H07V-R1 1.5 2 0.7 3.3 23 11
A3-A01-0025 H07V-U1 2.5 1 0.8 3.9 33 12
A3-A77-0025 H07V-R1 2.5 2 0.8 4.0 35 13
A3-A07-0004 H07V-R1 4 2 0.8 4.6 51 15
A3-A07-0006 H07V-R1 6 2 0.8 5.2 71 17
A3-A07-0010 H07V-R1 10 2 1.0 6.7 120 21
A3-A07-0016 H07V-R1 16 2 1.0 7.8 180 25
A3-A07-0025 H07V-R1 25 2 1.2 9.7 285 30
A3-A07-0035 H07V-R1 35 2 1.2 10.9 380 50
A3-A19-0050 H07V-R1 50 2 1.4 12.8 510 60
A3-A19-0070 H07V-R1 70 2 1.4 14.6 720 60
A3-A19-0095 H07V-R1 95 2 1.6 17.1 990 70
A3-A37-0120 H07V-R1 120 2 1.6 18.8 1230 80
A3-A37-0150 H07V-R1 150 2 1.8 20.9 1510 90
A3-A37-0185 H07V-R1 185 2 2.0 23.3 1900 100
A3-A61-0240 H07V-R1 240 2 2.2 26.6 2490 160
A3-A61-0300 H07V-R1 300 2 2.4 29.6 3100 180
A3-A61-0400 H07V-R1 400 2 2.6 33.2 3950 210
A3-A61-0500* A07V-R1 500 2 2.8 36.9 4950 230
A3-A12-0630* A07V-R1 630 2 2.8 41.1 6300 250
1:3
POWER & WIRING CABLES
®
* National TypeAll dimensions are nominal unless otherwise stated.For further technical information see page 1:80.For conductor short-circuit ratings see page 13:28.
1
1:4
POWER & WIRING CABLES
A P P L I C A T I O N S P E C I F I C A T I O N S
Single Core PVC/PVC 6181Y300/500 Volts
PVC insulated and sheathed cable for
fixed wiring purposes. Not suitable for
direct burial.
• In accordance with BS6004.
• Conductors: Solid Class 1 or stranded
Class 2 copper conductors to BS6360.
• Insulation: PVC insulation Type TI.1
to BS7655.
• Sheath: PVC sheath Type 6 to
BS7655.
• Flame retardant to BS4066 Part 1.
• Normal colours available.
(See 6491X page1:2)
• Temp Rating: 70oC max conductor
operating temperature.
• Voltage Rating: 300/500 volts.
®
1
POWER & WIRING CABLES
®
Anixter Nominal Conductor Insulation Min Max Approx Min BendingPart No. Conductor Class Thickness O/D O/D Weight Radius
Area (fixed bend)mm2 mm mm mm kg/km mm
A3-C01-0010 1.0 1 0.6 3.8 4.5 28 14
A3-C01-0015 1.5 1 0.7 4.2 4.9 34 15
A3-C01-0025 2.5 1 0.8 4.8 5.8 49 18
A3-C07-0004 4 2 0.8 5.4 6.8 75 21
A3-C07-0006 6 2 0.8 6.0 7.4 99 23
A3-C07-0010 10 2 1.0 7.2 8.8 155 27
A3-C07-0016 16 2 1.0 8.4 10.5 225 50
A3-C07-0025 25 2 1.2 10.0 12.5 340 50
A3-C07-0035 35 2 1.2 11.0 13.5 450 60
Sizes above 35mm2, are covered in BS6346.For further technical information see page 1:80.For conductor short-circuit ratings see page 13:28.
1:5
1
1:6
POWER & WIRING CABLES
A P P L I C A T I O N S P E C I F I C A T I O N S
Flat Twin & Flat Three Core PVC 6242Y & 6243Y Insulated & sheathed with uninsulated circuit protective conductor asoption.
PVC insulated and sheathed cable for
installation clipped to flat surfaces, or
embedded in plaster, etc.
For domestic and industrial wiring.
• In accordance with BS6004.
• Conductors: Solid Class 1 (up to
2.5mm2) and stranded Class 2 (above
2.5mm2) copper conductors to BS6360.
• Insulation: PVC insulation Type TI.1
to BS7655.
• Core identification:
2 core - red, black.
3 core - red, yellow, blue.
• PVC sheath Type 6 to BS7655.
• Position of protective conductor:
Twin - centrally placed between red
and black cores.
Three core - centrally placed between
yellow and blue cores.
• Flame retardant to BS4066 Part 1.
• Temp. Rating: 700C max conductor
operating temperature.
• Voltage Rating: 300/500V.
®
1
1:7
POWER & WIRING CABLES
®
Anixter Nominal Conductor Insulation Min Max Approx Min BendingPart No. Conductor Class Thickness O/D O/D Weight Radius
Area (fixed bend)mm2 mm mm mm kg/km mm
6192Y - Flat Twin
A3-D01-0010 1.0 1 0.6 4.0 x 6.2 4.7 x 7.4 54 23
A3-D01-0015 1.5 1 0.7 4.4 x 7.0 5.4 x 8.4 70 26
A3-D01-0025 2.5 1 0.8 5.2 x 8.4 6.2 x 9.8 105 30
A3-D07-0004 4 2 0.8 5.6 x 9.6 7.2 x 11.5 150 50
A3-D07-0006 6 2 0.8 6.4 x 10.5 8.0 x 13.0 205 60
A3-D07-0010 10 2 1.0 7.8 x 13.0 9.6 x 16.0 325 70
A3-D07-0016 16 2 1.0 9.0 x 15.5 11.0 x 18.5 465 80
6193Y - Flat Three Core
A3-D01-0310 1.0 1 0.6 4.0 x 8.4 4.7 x 9.8 77 30
A3-D01-0315 1.5 1 0.7 4.4 x 9.8 5.4 x 11.5 100 50
A3-D01-0325 2.5 1 0.8 5.2 x 11.5 6.2 x 13.5 150 60
A3-D07-0034 4 2 0.8 5.8 x 13.5 7.4 x 16.5 230 70
A3-D07-0036 6 2 0.8 6.4 x 15.0 8.0 x 18.0 300 80
A3-D07-0310 10 2 1.0 7.8 x 19.0 9.6 x 22.5 480 90
A3-D07-0316 16 2 1.0 9.0 x 22.0 11.0 x 26.5 700 160
For further technical information see page 1:84For conductor short-circuit ratings see page 13:28.
Nominal Insulation Min Max Nom Earth Approx Min BendingAnixter Conductor Conductor Thickness O/D O/D Conductor Weight RadiusPart No. Area Class Area (fixed bend)
A3-D07-3100 10 2 1.0 7.8 x 21.0 9.6 x 25.5 4 550 160
A3-D07-3160 16 2 1.0 9 x 24.5 11 x 29.5 6 790 180
1
1:8
POWER & WIRING CABLES1
A P P L I C A T I O N S P E C I F I C A T I O N S
Single Core PVC/PVC 6181Y600/1000 Volts
PVC-insulated and sheathed cable for
fixed installations.
Not suitable for direct burial.
• In accordance with BS6346.
• Conductors: Stranded Class 2
copper conductors to BS6360.
• Insulation: PVC insulation Type TI.1
to BS7655.
• Sheath: PVC sheath Type TM.1 to
BS7655.
• Flame retardant to BS4066 Part 1.
• Normal colours available.
(See 6491X page1:2)
• Temp Rating: 70oC max conductor
operating temperature.
• Voltage Rating: 600/1000 volts.
®
1:9
1POWER & WIRING CABLES
®
Anixter Nominal Insulation Nom Approx Min BendingPart No. Conductor Thickness O/D Weight Radius
Area (fixed bend)mm2 mm mm kg/km mm
A2-Q01-1050 50 1.4 15.1 600 70
A2-Q01-1070 70 1.4 16.9 810 70
A2-Q01-1095 95 1.6 19.4 1110 80
A2-Q01-1012 120 1.6 21.0 1350 90
A2-Q01-1015 150 1.8 23.2 1650 100
A2-Q01-1018 185 2.0 25.8 2060 160
A2-Q01-1024 240 2.2 29.0 2670 180
A2-Q01-1030 300 2.4 32.1 3320 200
A2-Q01-1040 400 2.6 35.8 4190 220
A2-Q01-1500 500 2.8 39.6 5230 240
A2-Q01-1063 630 2.8 43.8 6630 270
A2-Q01-1080 800 2.8 48.3 8330 290
A2-Q01-1001 1000 3.0 53.7 10440 330
All dimensions are nominal unless otherwise stated.
For further technical information see page 1:80.For conductor short-circuit ratings see page 13:28.For XLPE/PVC type to BS7889 see page 1:22.
1:10
POWER & WIRING CABLES1
®
Single Phase Straight ConcentricPCU/PVC/Straight Concentric/PVC 600/1000 Volts 700C
Single phase concentric cable, for
household and street lighting services.
Incorporates CNE (Combined Neutral
and Earth) to meet the requirements of
PME (Protective Multiple Earthing) in
various distribution systems.
Suitable for direct burial.
• In accordance with ESI* 09-7 & BS7870.
• Conductors: Stranded Class 2
central copper conductor to BS6360.
• Insulation: Red PVC insulation
Type TI.1 to BS7655.
• Helical CNE (Combined Neutral and
Earth) straight concentric comprising
of solid plain copper wires to BS4109.
• Sheath: Black PVC sheath
Type TM.1 to BS7655.
• Flame retardant to BS4066 Part 1.
• Temp Rating: 70oC max conductor
operating temperature.
• Voltage Rating: 600/1000 volts.
A P P L I C A T I O N S P E C I F I C A T I O N S
* ESI standards are now covered underEATS (Electricity Association TechnicalSpecification). Standard numberremains the same i.e. EATS 09-7
1:11
1POWER & WIRING CABLES
®
Also available with solid aluminium central conductor.
For further technical information see page 1:86.For conductor short-circuit ratings see page 13:28
Nominal Central Insulation No. and Nom Approx Min BendingAnixter Area of Conductor Thickness size of O/D Weight RadiusPart No. Central Stranding Concentric (fixed bend)
Conductor ConductorWires
mm2 #/mm mm #/mm mm kg/km mm
A3CE-0040 4 7/0.85 0.8 15/0.67 8.7 150 75
A3CE-0160 16 7/1.70 1.0 19/1.04 12.5 450 100
A3CE-0250 25 7/2.14 1.2 25/1.13 14.4 650 125
1:12
POWER & WIRING CABLES1
®
Single Phase Split ConcentricPCU/PVC/Split Concentric/PVC 600/1000 Volts 700C
Single phase split concentric cable, for
household and street lighting services.
Incorporates separate earth and
neutral wires.
Suitable for direct burial.
• In accordance with BS4553.
• Conductors: Stranded Class 2
central copper conductor to BS6360.
• Insulation: Red PVC insulation
Type TI.1 to BS7655.
• Helical Split Concentric comprising of:
• Solid plain copper earth wires to
BS4109 plus PVC insulated plain
copper neutral wires.
• Two or more PVC string fillers are
utilised to divide the bare copper
earth wires and the PVC insulated
neutral wires.
• Sheath: Black PVC sheath
Type TM.1 to BS7655.
• Flame retardant to BS4066 Part 1.
• Temp Rating: 70oC max conductor
operating temperature.
• Voltage Rating: 600/1000 volts.
A P P L I C A T I O N S P E C I F I C A T I O N S
1:13
1POWER & WIRING CABLES
®
Also available with solid aluminium central conductor.For further technical information see page 1:86.For conductor short-circuit ratings see page 13:28.* Insulation thickness may be enhanced to allow split concentric to fit helically around the insulated central conductor
A3BN-0040 4 0.8* 7/0.85 3/1.35 10.2 206 100
A3BN-0060 6 1.0 7/1.04 4/1.53 11.2 281 100
A3BN-0100 10 1.0 7/1.35 4/1.78 12.6 394 125
A3BN-0160 16 1.0 7/1.70 4/2.25 14.6 583 125
A3BN-0250 25 1.2* 11/1.70 4/2.25 18.1 843 150
A3BN-0350 35 1.2* 15/1.70 6/2.25 22.6 1248 200
Nominal Insulation No. and No. and Nom Approx Min BendingAnixter Area of Thickness size of size of O/D Weight RadiusPart No. Central Neutral Earth (fixed bend)
Conductor Wires Wires
mm2 mm #/mm #/mm mm kg/km mm
1:14
POWER & WIRING CABLES1
®
Three Phase Straight ConcentricPCU/PVC/Straight Concentric/PVC 600/1000 Volts 700C
Three phase concentric cable for mains
services requiring 3-phase supply.
Incorporates CNE (Combined Neutral
and Earth) to meet the requirements of
PME (Protective Multiple Earthing) in
various distribution systems.
Suitable for direct burial.
• In accordance with ESI* 09-7 & BS7870.
• Conductors: Stranded Class 2
copper conductors to BS6360.
• Insulation: PVC insulation Type TI.1
to BS7655.
• Core Identification: Red, Yellow Blue
• PVC tape bedding applied over
laid-up cores.
• Helical CNE (Combined Neutral and
Earth) straight concentric comprising
of solid plain copper wires to BS4109.
• Sheath: Black PVC sheath
Type TM.1 to BS7655.
• Flame retardant to BS4066 Part 1.
• Temp Rating: 70oC max conductor
operating temperature.
• Voltage Rating: 600/1000 volts.
A P P L I C A T I O N S P E C I F I C A T I O N S
* ESI standards are now covered underEATS (Electricity Association TechnicalSpecification). Standard numberremains the same i.e. EATS 09-7
1:15
1POWER & WIRING CABLES
®
Nominal Insulation No. and Nom Approx Min BendingAnixter Area Thickness size of O/D Weight RadiusPart No. of Phase Concentric (fixed bend)
Conductors ConductorWires
mm2 mm #/mm kg/km mm mm
A2EM-0160 16 * 1.0 48/0.67 22.1 900 200
A2EM-0250 25 * 1.2 56/0.75 26.0 1300 200
* Circular or circularcompacted stranded conductors.Also available with solid aluminium conductors.
For further technical information see page 1:86.For conductor short-circuit ratings see page 13:28.
1:16
POWER & WIRING CABLES1
A P P L I C A T I O N S P E C I F I C A T I O N S
PVC/PVC/SWA/PVC Armoured Power &Control Cable 600/1000 Volts
For use in fixed installations, indoor,
outdoor or direct burial.
Cables buried in sustained wet conditions
should have extruded bedding.
Where waterlogging is likely to occur,
technical advice should be sought as to
a suitable type of cable.
• In accordance with BS6346.• Conductors: Stranded Class 2 copper
conductors to BS6360. Solid Class 1 conductors are also available for 1.5 and 2.5mm2.
Improved fire performance is available by using a reduced propagation, low HCL emission PVCouter sheath.
• Temp Rating: 70oC max conductor
operating temperature.
• Voltage Rating: 600/1000 volts
®
1:17
1POWER & WIRING CABLES
®
Nominal Insulation Diam Armour Nom Approx Min BendingAnixter Conductor Conductor Thickness under wire O/D Weight RadiusPart No. Area Class armour size (fixed bend)
mm2 mm mm mm mm kg/km mm
Type 6942X - Two Core
A3-G02-2015 1.5 1 0.6 7.3 0.9 11.7 280 80
A3-G02-2015Q 1.5 2 0.6 7.9 0.9 12.3 300 80
A3-G02-2025 2.5 1 0.7 8.5 0.9 13.1 350 80
A3-G02-2025Q 2.5 2 0.7 9.0 0.9 13.6 360 90
A2-S02-2004 4 2 0.8 10.5 0.9 15.1 475 100
A2-S02-2006 6 2 0.8 11.7 0.9 16.5 550 100
A2-S02-2010 10 2 1.0 14.4 1.25 20.1 850 130
A2-S02-2016 16 2 1.0 16.2 1.25 21.9 990 140
Type 6943X - Three Core
A3-G03-3015 1.5 1 0.6 7.7 0.9 12.3 325 80
A3-G03-3015Q 1.5 2 0.6 8.2 0.9 12.8 340 80
A3-G03-3025 2.5 1 0.7 9.0 0.9 13.6 400 90
A3-G03-3025Q 2.5 2 0.7 9.5 0.9 14.1 410 90
A2-T03-3004 4 2 0.8 11.2 0.9 15.8 525 100
A2-T03-3006 6 2 0.8 12.5 1.25 18.0 750 110
A2-T03-3010 10 2 1.0 15.5 1.25 21.2 1025 130
A2-T03-3016 16 2 1.0 17.4 1.25 23.1 1120 140
Type 6944X - Four Core
A3-G04-4015 1.5 1 0.6 8.4 0.9 13.0 360 80
A3-G04-4015Q 1.5 2 0.6 8.9 0.9 13.5 390 90
A3-G04-4025 2.5 1 0.7 9.9 0.9 14.5 440 90
A3-G04-4025Q 2.5 2 0.7 10.4 0.9 15.0 460 90
A2-U04-4004 4 2 0.8 12.3 1.25 17.8 725 110
A2-U04-4006 6 2 0.8 13.7 1.25 19.2 850 120
A2-U04-4010 10 2 1.0 17.1 1.25 22.8 1200 140
A2-U04-4016 16 2 1.0 19.7 1.6 26.3 1530 160
Continued overleaf. . .
®
A3-H01-1005Q 5 1.5 2 0.6 9.7 0.9 14.3 410 90
A3-H01-1007Q 7 1.5 2 0.6 10.6 0.9 15.2 470 100
A3-H01-1010Q 10 1.5 2 0.6 13.5 1.25 19.0 730 120
A3-H01-1012Q 12 1.5 2 0.6 13.9 1.25 19.4 780 120
A3-H01-1019Q 19 1.5 2 0.6 16.5 1.25 22.2 1020 140
A3-H01-1027Q 27 1.5 2 0.6 20.1 1.6 26.7 1510 170
A3-H01-1037Q 37 1.5 2 0.6 22.4 1.6 29.2 1830 180
A3-H01-1048Q 48 1.5 2 0.6 25.9 1.6 32.9 2200 200
A3-H01-2005Q 5 2.5 2 0.7 11.5 0.9 16.3 530 100
A3-H01-2007Q 7 2.5 2 0.7 12.5 1.25 18.0 730 110
A3-H01-2010Q 10 2.5 2 0.7 16.2 1.25 21.9 950 140
A3-H01-2012Q 12 2.5 2 0.7 16.7 1.25 22.4 1050 140
A3-H01-2019Q 19 2.5 2 0.7 20.0 1.6 26.6 1600 160
A3-H01-2027Q 27 2.5 2 0.7 23.9 1.6 30.7 2040 190
A3-H01-2037Q 37 2.5 2 0.7 27.0 1.6 34.0 2520 210
A3-H01-2048Q 48 2.5 2 0.7 31.3 2.0 39.5 3340 240
A3-H04-4005 5 4 2 0.8 13.5 1.25 19.0 810 120
A3-H04-4007 7 4 2 0.8 14.8 1.25 20.5 950 130
A3-H04-4010 10 4 2 0.8 19.5 1.6 26.1 1460 160
A3-H04-4012 12 4 2 0.8 20.2 1.6 26.8 1560 170
A3-H04-4019 19 4 2 0.8 23.7 1.6 30.5 2080 190
A3-H04-4027 27 4 2 0.8 29.1 2.0 37.1 3030 230
1:18
POWER & WIRING CABLES1
Nominal Insulation Diam Armour Nom Approx Min Bending
Anixter No. of Conductor Conductor Thickness under wire O/D Weight Radius
Part No. Cores Area Class armour size (fixed bend)
(mm2) mm mm mm mm kg/km mm
PVC/PVC/SWA/PVC Armoured Power &Control Cable 600/1000 Volts Continued. . .
For more technical information see page 1:88.
For conductor short-circuit ratings see page 13:28.For armour short-circuit ratings see page 13:41.
1:19
1POWER & WIRING CABLES
®
A P P L I C A T I O N S P E C I F I C A T I O N S
1:20
POWER & WIRING CABLES1
®
PVC/PVC/SWA/PVC Armoured ControlCable to ESI* 09-6 600/1000 Volts
Control cables for fixed installation,
indoor, outdoor or direct burial.
• In accordance with ESI 09-6
• Conductors:Stranded Class 2 copper
to BS6360.
• Insulation: PVC insulation Type TI.1
to BS7655.
• Core identification: Number printed in
black ink on white PVC insulation.
• Inner Sheath: PVC sheath Type
TM.1 to BS7655.
• Mild galvanised steel wires to BSEN10257-1
• Outer Sheath: Reduced propagation,
low HCL emission PVC sheath.
Meets Type TM.1 to BS7655 and in
addition displays following characteristics:
Oxygen Index: 30% min
HCL emission @ 8000C: 15% max
• Flame retardant to BS4066 Part 3.
• Temp Rating: 700C max conductor
operating temperature.
• Voltage Rating: 600/1000 volts* ESI standards are now covered underEATS (Electricity Association TechnicalSpecification). Standard numberremains the same i.e. EATS 09-6
1:21
1POWER & WIRING CABLES
®
Number Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness under wire O/D Weight RadiusPart No. Cores Area armour size (fixed bend)
mm2 mm mm mm mm kg/km mm
A3-K02-2073 2 1.5 0.6 7.7 0.9 12.3 300 80
A3-K03-2078 3 1.5 0.6 8.2 0.9 12.8 340 80
A3-K04-2087 4 1.5 0.6 8.9 0.9 13.5 390 90
A3-K05-2099 5 1.5 0.6 9.7 0.9 14.3 430 90
A3-K07-2108 7 1.5 0.6 10.6 0.9 15.2 470 100
A3-K10-2148 10 1.5 0.6 13.5 1.25 19.0 730 120
A3-K12-2148 12 1.5 0.6 13.9 1.25 19.4 780 120
A3-K19-2178 19 1.5 0.6 16.5 1.25 22.2 1020 140
A3-K27-2219 27 1.5 0.6 20.1 1.6 26.7 1510 170
A3-K37-2248 37 1.5 0.6 22.4 1.6 29.2 1830 180
A3-K02-1073 2 2.5 0.7 8.9 0.9 13.6 360 90
A3-K03-1078 3 2.5 0.7 9.4 0.9 14.1 410 90
A3-K04-1087 4 2.5 0.7 10.3 0.9 15.0 460 90
A3-K05-1099 5 2.5 0.7 11.5 0.9 16.3 530 100
A3-K07-1108 7 2.5 0.7 12.4 1.25 18.0 720 110
A3-K10-1148 10 2.5 0.7 16.2 1.25 21.9 930 140
A3-K12-1148 12 2.5 0.7 16.5 1.25 22.4 1030 140
A3-K19-1178 19 2.5 0.7 19.8 1.6 26.6 1530 160
A3-K27-1219 27 2.5 0.7 23.9 1.6 30.7 1960 190
A3-K37-1248 37 2.5 0.7 26.8 1.6 34.0 2490 210
For further technical information see page 1:88.
For conductor short-circuit ratings refer to page 13:28.For armour short-circuit ratings refer to page 13:41.
1:22
POWER & WIRING CABLES1
A P P L I C A T I O N S P E C I F I C A T I O N S
Single Core XLPE/PVC600/1000 Volts
XLPE insulated and PVC sheathed
cable for fixed installation.
Not suitable for direct burial.
• In accordance with BS7889.
• Conductors: Stranded Class 2
copper conductors to BS6360.
• Insulation: XLPE insulation Type
GP8 to BS7655.
• Sheath: PVC sheath Type 9 to
BS7655.
• Flame retardant to BS4066 Part 1.
• Normal colours available.
(See 6491X page1:2)
• Temp. Rating: 90oC max conductor
operating temperature.
• Voltage Rating: 600/1000 volts.
®
1:23
1POWER & WIRING CABLES
®
Anixter Nominal Insulation Nom Approx Min BendingPart No. Conductor Thickness O/D Weight Radius
Area (fixed bend)mm2 mm mm kg/km mm
A2EG-0500 50 1.0 14.2 540 60
A2EG-0700 70 1.1 16.2 750 70
A2EG-0950 95 1.1 18.3 1010 80
A2EG-1200 120 1.2 20.2 1250 90
A2EG-1500 150 1.4 22.4 1530 90
A2EG-1850 185 1.6 24.7 1900 100
A2EG-2400 240 1.7 27.7 2470 170
A2EG-3000 300 1.8 30.6 3080 190
A2EG-4000 400 2.0 34.2 3890 210
A2EG-5000 500 2.2 38.0 4970 230
A2EG-6300 630 2.4 42.9 6370 260
A2EG-8000 800 2.6 47.8 8300 290
A2EG-1000 1000 2.8 53.0 10341 320
All dimensions are nominal unless otherwise stated.For further technical information see page 1:92.For conductor short-circuit ratings refer to page 13:29.Additional information refer to 1:104.
®
POWER & WIRING CABLES1
Single Core XLPE/PVC/AWA/PVC PowerCable 600/1000 Volts & 1900/3300 Volts
Armoured single core cable for use in
fixed installations, indoor, outdoor or
direct burial.
• In accordance with BS5467
• Conductors: Stranded Class 2 copper
conductors to BS6360.
• Insulation: XLPE insulation Type
GP8 to BS7655.
• Inner Sheath: PVC inner sheath
Type 9 to BS7655.
• Aluminium wires to BS2627
• Outer Sheath: Black PVC outer
sheath Type 9 to BS7655.
• Flame retardant to BS4066 Part 1.
• Temp Rating: 900C max conductor
operating temperature.
• Voltage Rating: 600/1000 &
1900/3300 volts
1:24
A P P L I C A T I O N S P E C I F I C A T I O N S
1:25
1POWER & WIRING CABLES
®
Number Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size (fixed bend)
mm2 mm mm mm mm kg/km mm
600/1000V Cables
A2B0-0500 1 50 1.0 12.7 0.9 17.5 800 110
A2B0-0700 1 70 1.1 14.7 1.25 20.2 940 130
A2B0-0950 1 95 1.1 16.6 1.25 22.3 1220 140
A2B0-1200 1 120 1.2 18.5 1.25 24.2 1490 150
A2B0-1500 1 150 1.4 20.8 1.6 27.4 1870 170
A2B0-1850 1 185 1.6 23.2 1.6 30.0 2290 180
A2B0-2400 1 240 1.7 26.0 1.6 32.8 2880 200
A2B0-3000 1 300 1.8 28.6 1.6 35.6 3520 220
A2B0-4000 1 400 2.0 32.4 2.0 40.4 4500 250
A2B0-5000 1 500 2.2 36.0 2.0 44.2 5680 270
A2B0-6300 1 630 2.4 40.4 2.0 48.8 7160 300
A2B0-8000 1 800 2.6 45.6 2.5 55.4 9400 340
A2B0-10000 1 1000 2.8 50.6 2.5 60.6 11600 370
1900/3300V Cables
A2BX-0500 1 50 2.0 14.9 1.25 20.6 810 130
A2BX-0700 1 70 2.0 16.7 1.25 22.4 1040 140
A2BX-0950 1 95 2.0 18.6 1.25 24.3 1330 150
A2BX-1200 1 120 2.0 20.6 1.6 27.2 1680 170
A2BX-1500 1 150 2.0 22.2 1.6 28.8 1970 180
A2BX-1850 1 185 2.0 24.0 1.6 30.8 2370 190
A2BX-2400 1 240 2.0 26.6 1.6 33.4 2960 210
A2BX-3000 1 300 2.0 29.1 1.6 36.1 3610 220
A2BX-4000 1 400 2.0 32.4 2.0 40.4 4600 250
A2BX-5000 1 500 2.2 36.0 2.0 44.2 5680 270
A2BX-6300 1 630 2.4 40.4 2.0 48.8 7160 300
A2BX-8000 1 800 2.6 45.6 2.5 55.4 9400 340
A2BX-10000 1 1000 2.8 50.6 2.5 60.6 11600 370
For further technical information see page 1:100. (See 1:114 for technical informationon 1900/3300V cables)
For conductor and armour resistances refer page 13:31.For Gross Cross-Sectional area of armour refer to page 13:34.For conductor short-circuit ratings refer to page 13:29.For armour short-circuit ratings refer to page 13:36.
1:26
POWER & WIRING CABLES1
®
XLPE/PVC Multicore Power Cable 600/1000 Volts
Insulated and sheathed cable for use in
fixed installations.
Not suitable for direct burial.
• In accordance with BS5467
(1989 issue only)
• Conductors: Stranded Class 2 copper
conductors to BS6360.
• Insulation: XLPE insulation Type
GP8 to BS7655.
• Core identification:
2 core - red, black
3 core - red, yellow, blue
4 core - red, yellow, blue, black
• Outer Sheath: Black PVC outer
sheath Type 9 to BS7655.
• Flame retardant to BS4066 Part 1.
• Temp Rating: 900C max conductor
operating temperature
• Voltage Rating: 600/1000 volts
* Circular or circular compacted stranded conductors.\\ Cables having conductors of nominal area 50mm2 and above have shaped stranded conductors.
A P P L I C A T I O N S P E C I F I C A T I O N S
1:27
1POWER & WIRING CABLES
®
Anixter Number Nominal Insulation Nom Approx Min BendingPart No. of Conductor Thickness O/D Weight Radius
Cores Area (fixed bend)mm2 mm mm kg/km mm
A2DT-0160 2 16* 0.7 17.2 490 70
A2DT-0250 2 25* 0.9 20.8 660 90
A2DT-0350 2 35* 0.9 23.2 880 100
A2DT-0500 2 50 \\ 1.0 21.0 1100 170
A2DT-0700 2 70 1.1 24.0 1520 200
A2DT-0950 2 95 1.1 26.9 2040 220
A2DT-1200 2 120 1.2 29.9 2570 240
A2DT-1500 2 150 1.4 33.4 3130 270
A2DT-1850 2 185 1.6 37.1 3920 300
A2DT-2400 2 240 1.7 41.7 5050 340
A2DT-3000 2 300 1.8 45.8 6350 370
A2DT-4000 2 400 2.0 51.6 8000 420
A2DU-0160 3 16* 0.7 18.3 640 80
A2DU-0250 3 25* 0.9 22.1 920 90
A2DU-0350 3 35* 0.9 24.8 1190 100
A2DU-0500 3 50 \\ 1.0 23.6 1580 190
A2DU-0700 3 70 1.1 27.4 2220 220
A2DU-0950 3 95 1.1 30.8 2980 250
A2DU-1200 3 120 1.2 34.2 3730 280
A2DU-1500 3 150 1.4 37.9 4580 310
A2DU-1850 3 185 1.6 42.5 5740 340
A2DU-2400 3 240 1.7 47.8 7450 390
A2DU-3000 3 300 1.8 52.6 9230 430
A2DU-4000 3 400 2.0 59.2 11720 480
A2DV-0160 4 16* 0.7 20.0 820 80
A2DV-0250 4 25* 0.9 24.3 1170 100
A2DV-0350 4 35* 0.9 27.3 1550 170
A2DV-0500 4 50 \\ 1.0 26.9 2050 220
A2DV-0700 4 70 1.1 31.5 2900 260
A2DV-0950 4 95 1.1 35.6 3920 290
A2DV-1200 4 120 1.2 39.5 4940 320
A2DV-1500 4 150 1.4 44.1 6040 360
A2DV-1850 4 185 1.6 49.3 7580 400
A2DV-2400 4 240 1.7 55.5 9860 450
A2DV-3000 4 300 1.8 61.4 12280 500
A2DV-4000 4 400 2.0 68.8 15000 560
Continued overleaf. . .
POWER & WIRING CABLES
®
A2DW-02516 4 25* 16* 0.9 0.7 23.3 900 100
A2DW-03516 4 35* 16* 0.9 0.7 25.7 1100 160
A2DW-05025 4 50 \\ 25† 1.0 0.9 26.1 1400 210
A2DW-07035 4 70 35 1.1 0.9 30.4 2600 250
A2DW-09550 4 95 50 1.1 1.0 34.8 3500 280
A2DW-12070 4 120 70 1.2 1.1 39.4 4500 320
A2DW-15070 4 150 70 1.4 1.1 42.5 5150 340
A2DW-18595 4 185 95 1.6 1.1 47.7 6600 390
A2DW-24012 4 240 120 1.7 1.2 53.4 8500 430
A2DW-30015 4 300 150 1.8 1.4 59.0 10200 480
A2DW-30018 4 300 185 1.8 1.6 61.2 10700 490
A2DW-40018 4 400 185 2.0 1.6 66.4 14350 540
1
Number Nominal Nominal Insulation Insulation Nom Approx Min BendingAnixter of Phase Neutral Thickness Thickness O/D Weight RadiusPart No. Cores Conductor Conductor (Phase) (Neutral) (fixed bend)
Area (mm2) Area (mm2) (mm) (mm) (mm) kg/km (mm)
XLPE/PVC Multicore Power Cable 600/1000 Volts Continued. . .
1:28
*Circular or circular compacted stranded conductors.\\ Cables having conductors of nominal area 50mm2 and above have shaped stranded conductors.† Neutral conductors of nominal area 25mm2 and above may have shaped, circular or circular compactedstranded conductors.
For further technical information see page 1:96.For conductor short-circuit ratings refer to page 13:29.
1:29
1POWER & WIRING CABLES
®
®
POWER & WIRING CABLES1
Multi-Core XLPE/PVC/SWA/PVC Power Cable 600/1000 Volts & 1900/3300 Volts
Armoured cables for use in fixed
installations for use indoor, outdoor or
for direct burial.
• In accordance with BS5467
• Conductors: Stranded Class 2 copper
conductors to BS6360.
• Insulation: XLPE insulation Type
GP8 to BS7655.
• Core identification:
2 core - red, black
3 core - red, yellow, blue
4 core - red, yellow, blue, black
5 core + above - number printed
• Inner Sheath: PVC inner sheath
Type 9 to BS7655.
• Mild galvanised steel wires to BSEN10257-1
• Outer Sheath: Black PVC outer
sheath Type 9 to BS7655.
• Flame retardant to BS4066 Part 1.
• Temp Rating: 900C max conductor
operating temperature
• Voltage Rating: 600/1000 volts
NB: 1900/3300 Volts only available in3 core
1:30
A P P L I C A T I O N S P E C I F I C A T I O N S
1:31
1POWER & WIRING CABLES
®
Number Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size (fixed bend)
mm2 mm mm mm mm kg/km mm
600/1000V
A2BQ-0015Q 2 1.5* 0.6 7.7 0.9 12.3 295 80
A2BQ-0025Q 2 2.5* 0.7 9.0 0.9 13.6 345 90
A2BQ-0040 2 4* 0.7 10.1 0.9 14.7 409 90
A2BQ-0060 2 6* 0.7 11.3 0.9 15.9 485 100
A2BQ-0100 2 10* 0.7 13.2 0.9 18.0 635 110
A2BQ-0160 2 16† 0.7 14.5 1.25 20.0 900 120
A2BQ-0250 2 25† 0.9 18.4 1.25 24.1 1060 150
A2BQ-0350 2 35† 0.9 21.3 1.6 27.9 1490 170
A2BQ-0500 2 50 \\ 1.0 19.0 1.6 25.8 1800 210
A2BQ-0700 2 70 1.1 22.0 1.6 29.0 2320 240
A2BQ-0950 2 95 1.1 25.1 2.0 33.1 3160 270
A2BQ-1200 2 120 1.2 27.9 2.0 36.1 3790 290
A2BQ-1500 2 150 1.4 30.9 2.0 39.3 4500 320
A2BQ-1850 2 185 1.6 34.9 2.5 44.7 5820 360
A2BQ-2400 2 240 1.7 39.0 2.5 49.0 7220 400
A2BQ-3000 2 300 1.8 43.3 2.5 53.5 8710 430
A2BQ-4000 2 400 2.0 48.4 2.5 59.0 11100 480
A2BS-0015Q 3 1.5* 0.6 8.2 0.9 12.8 330 80
A2BS-0025Q 3 2.5* 0.7 9.5 0.9 14.1 390 90
A2BS-0040 3 4* 0.7 10.7 0.9 15.3 470 100
A2BS-0060 3 6* 0.7 12.0 0.9 16.6 570 100
A2BS-0100 3 10* 0.7 14.0 1.25 19.5 880 120
A2BS-0160 3 16† 0.7 15.5 1.25 21.2 1070 130
A2BS-0250 3 25† 0.9 20.1 1.6 26.7 1550 170
A2BS-0350 3 35† 0.9 22.8 1.6 29.6 1940 180
A2BS-0500 3 50 \\ 1.0 21.7 1.6 28.5 2360 230
A2BS-0700 3 70 1.1 25.2 1.6 32.2 3120 260
A2BS-0950 3 95 1.1 28.8 2.0 37.0 4310 300
A2BS-1200 3 120 1.2 32.0 2.0 40.4 5160 330
A2BS-1500 3 150 1.4 35.9 2.5 45.5 6610 370
A2BS-1850 3 185 1.6 40.0 2.5 49.8 7920 400
A2BS-2400 3 240 1.7 44.9 2.5 55.1 9930 450
A2BS-3000 3 300 1.8 49.8 2.5 60.2 11970 490
A2BS-4000 3 400 2.0 55.8 2.5 66.6 14770 540
*Circular stranded conductors.\\ Cables having conductors of nominal area 50mm2 and above have shaped stranded conductors.† Circular or circular compacted stranded conductors. Continued overleaf. . .
®
Number Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size (fixed bend)
mm2 mm mm mm mm kg/km mm
600/1000V
A2BU-0015Q 4 1.5* 0.6 8.9 0.9 13.5 380 90
A2BU-0025Q 4 2.5* 0.7 10.4 0.9 15.0 450 90
A2BU-0040 4 4* 0.7 11.8 0.9 16.4 560 100
A2BU-0060 4 6* 0.7 13.2 1.25 18.7 790 120
A2BU-0100 4 10* 0.7 15.6 1.25 21.1 1040 130
A2BU-0160 4 16† 0.7 17.2 1.25 22.9 1300 140
A2BU-0250 4 25† 0.9 22.3 1.6 28.9 1880 180
A2BU-0350 4 35† 0.9 25.3 1.6 32.1 2350 200
A2BU-0500 4 50 \\ 1.0 25.0 1.6 32.0 2950 260
A2BU-0700 4 70 1.1 29.5 2.0 37.7 4230 320
A2BU-0950 4 95 1.1 33.3 2.0 41.7 5390 340
A2BU-1200 4 120 1.2 37.5 2.5 47.1 6890 380
A2BU-1500 4 150 1.4 41.6 2.5 51.4 8300 420
A2BU-1850 4 185 1.6 46.4 2.5 56.6 10070 460
A2BU-2400 4 240 1.7 52.6 2.5 63.0 12680 510
A2BU-3000 4 300 1.8 58.0 2.5 68.8 15380 560
A2BU-4000 4 400 2.0 65.4 3.15 78.1 19950 630
A3AM-C007Q 7 1.5* 0.6 10.6 0.9 15.2 488 100
A3AM-C012Q 12 1.5* 0.6 13.9 1.25 19.4 817 120
A3AM-CO19Q 19 1.5* 0.6 16.5 1.25 22.2 1225 140
A3AM-C027Q 27 1.5* 0.6 20.1 1.6 26.7 1553 170
A3AM-C037Q 37 1.5* 0.6 22.4 1.6 29.2 1859 180
A3AP-C007Q 7 2.5* 0.7 12.5 0.9 17.1 685 110
A3AP-C012Q 12 2.5* 0.7 16.7 1.25 22.4 910 140
A3AP-C019Q 19 2.5* 0.7 20.0 1.6 26.6 1500 160
A3AP-C027Q 27 2.5* 0.7 23.9 1.6 30.7 1928 190
A3AP-C037Q 37 2.5* 0.7 27.0 1.6 33.8 2360 210
POWER & WIRING CABLES1
Multi-Core XLPE/PVC/SWA/PVC Power Cable 600/1000 Volts & 1900/3300 Volts
Continued. . .
1:32
1:33
1POWER & WIRING CABLES
®
Number Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size (fixed bend)
mm2 mm mm mm mm kg/km mm
1900/3300V Cables
A2BZ-0160 3 16† 2.0 22.1 1.6 28.9 1600 180
A2BZ-0250 3 25† 2.0 25.4 1.6 32.2 2060 200
A2BZ-0350 3 35† 2.0 28.0 1.6 35.0 2320 210
A2BZ-0500 3 50 \\ 2.0 26.7 2.0 34.7 3040 280
A2BZ-0700 3 70 2.0 29.8 2.0 38.0 3800 310
A2BZ-0950 3 95 2.0 33.0 2.0 41.4 4730 340
A2BZ-1200 3 120 2.0 36.1 2.5 45.7 6070 370
A2BZ-1500 3 150 2.0 38.7 2.5 48.5 7010 390
A2BZ-1850 3 185 2.0 41.9 2.5 51.9 8270 420
A2BZ-2400 3 240 2.0 46.7 2.5 56.9 10310 460
A2BZ-3000 3 300 2.0 50.8 2.5 61.2 12300 490
A2BZ-4000 3 400 2.0 55.8 2.5 66.6 15050 540
*Circular stranded conductors.\\ Cables having conductors of nominal area 50mm2 and above have shaped stranded conductors.† Circular or circular compacted stranded conductors.
For further technical information see page 1:106. (See 1:114 for technical informationon 1900/3300V cables).
For conductor and armour resistances refer page 13:32.For Gross Cross-Sectional area of armour refer to page 13:35.For conductor short-circuit ratings refer to page 13:29.For armour short-circuit ratings refer to page 13:37.
A P P L I C A T I O N S P E C I F I C A T I O N S
1:34
POWER & WIRING CABLES1
®
Single Core LSF 6491B900C 300/500 & 450/750 Volts
LSF insulated only cable for fixed wiring
purposes. Used in trunking or conduit,
or may be surface mounted when used
for earthing.
Especially for use in areas where fire
would create dense smoke and toxic
fumes causing a major threat to life and
equipment.
• In accordance with BS7211 and
Cenelec harmonised codes
H07Z-U (Solid conductors)
H07Z-R (Stranded conductors)
• Conductors: Solid Class 1 or
Stranded Class 2 copper conductors
to BS6360.
• Insulation: Low smoke zero halogen
thermosetting insulation Type EI.5 to
BS7655, displaying following
characteristics:
Oxygen Index: 30% min
HCL emission @ 8000C: 0.5% max
• Flame retardant to BS4066 Part 2
(up to and incl. 1.0mm2) and BS4066
Part 1 (above 1.0mm2).
• Normal colours available.
(see 6491X p1:2)
• Temp Rating: 900C max conductor
operating temperature.
• Voltage Rating:
Up to and including 1.0mm2 - 300/500V
1.5mm2 and above - 450/750V
1:35
1POWER & WIRING CABLES
®
Anixter Cenelec Nominal Conductor Insulation Max Approx Min BendingPart No. Code Conductor Class Thickness O/D Weight Radius
Area (fixed bend)mm2 mm mm kg/km mm
A3BR-0015 H07Z-U1 1.5 1 0.7 3.3 20 10
A3BT-0015 H07Z-R1 1.5 2 0.7 3.4 22 11
A3BR-0025 H07Z-U1 2.5 1 0.8 4.0 31 12
A3BT-0025 H07Z-R1 2.5 2 0.8 4.1 33 13
A3BT-0040 H07Z-R1 4 2 0.8 4.7 49 15
A3BT-0060 H07Z-R1 6 2 0.8 5.4 69 17
A3BT-0100 H07Z-R1 10 2 1.0 7.0 116 21
A3BT-0160 H07Z-R1 16 2 1.0 8.0 175 24
A3BT-0250 H07Z-R1 25 2 1.2 10.1 273 30
A3BT-0350 H07Z-R1 35 2 1.2 11.3 367 50
A3BT-0500 H07Z-R1 50 2 1.4 13.2 495 60
A3BT-0700 H07Z-R1 70 2 1.4 15.1 699 60
A3BT-0950 H07Z-R1 95 2 1.6 17.6 968 70
A3BT-1200 H07Z-R1 120 2 1.6 19.4 1164 80
A3BT-1500 H07Z-R1 150 2 1.8 21.6 1413 90
A3BT-1850 H07Z-R1 185 2 2.0 24.1 1828 100
A3BT-2400 H07Z-R1 240 2 2.2 27.5 2320 160
A3BT-3000 H07Z-R1 300 2 2.4 30.6 2988 180
A3BT-4000 H07Z-R1 400 2 2.6 34.3 3800 210
A3BT-5000 H07Z-R1 500 2 2.8 38.2 4750 230
A3BT-6300* A07Z-R1 630 2 2.8 42.5 6050 250
* = National TypeAll dimensions are nominal unless otherwise stated.For further technical information see page 1:92.For conductor short-circuit ratings refer to page 13:29 for XLPE insulated cable.
1:36
POWER & WIRING CABLES1
®
Single Core XLPE/LSF/AWA/LSF PowerCable 600/1000 Volts & 1900/3300 Volts
• In accordance with BS6724
• Conductors: Stranded Class 2
copper conductors.
• Insulation: XLPE insulation Type
GP8 to BS7655.
• Inner Sheath: LSF inner sheath
Type LTS1 to BS7655.
• Aluminium wires to BS2627.
• Outer Sheath: Black LSF outer
sheath Type LTS1 to BS7655.
• Flame retardant to BS4066/IEC60332
Part 3 Category A (NMV7).
• Temp Rating: 90oC max conductor
operating temperature.
• Voltage Rating: 600/1000 &
1900/3300V.
LSF insulated, armoured and
sheathed, single core power cable for
use in fixed installations.
Especially for use in areas where fire
would create dense smoke and toxic
fumes causing a major threat to life and
equipment.
A P P L I C A T I O N S P E C I F I C A T I O N S
600/1000V Cables
A2-AT-0500 1 50 1.0 12.7 0.9 17.5 710 110
A2-AT-0700 1 70 1.1 14.7 1.25 20.2 940 130
A2-AT-0950 1 95 1.1 16.6 1.25 22.3 1220 140
A2-AT-1200 1 120 1.2 18.5 1.25 24.2 1480 150
A2-AT-1500 1 150 1.4 20.8 1.6 27.4 1870 150
A2-AT-1850 1 185 1.6 23.2 1.6 30.0 2280 180
A2-AT-2400 1 240 1.7 26.0 1.6 32.8 2880 200
A2-AT-3000 1 300 1.8 28.6 1.6 35.6 3520 220
A2-AT-4000 1 400 2.0 32.4 2.0 40.4 4520 250
A2-AT-5000 1 500 2.2 36.0 2.0 44.2 5640 270
A2-AT-6300 1 630 2.4 40.4 2.0 48.8 7110 300
A2-AT-8000 1 800 2.6 45.6 2.5 55.4 9390 340
A2-AT-10000 1 1000 2.8 50.6 2.5 60.6 11580 370
1900/3300V Cables
A2-AY-0500 1 50 2.0 14.9 1.25 20.6 800 130
A2-AY-0700 1 70 2.0 16.7 1.25 22.4 1020 140
A2-AY-0950 1 95 2.0 18.6 1.25 24.3 1300 150
A2-AY-1200 1 120 2.0 20.6 1.6 27.2 1650 170
A2-AY-1500 1 150 2.0 22.2 1.6 28.8 1930 180
A2-AY-1850 1 185 2.0 24.0 1.6 30.8 2330 190
A2-AY-1240 1 240 2.0 26.6 1.6 33.4 2910 210
A2-AY-1300 1 300 2.0 29.1 1.6 36.1 3540 220
A2-AY-1400 1 400 2.0 32.4 2.0 40.4 4520 250
A2-AY-1500 1 500 2.2 36.0 2.0 44.2 5640 270
A2-AY-1630 1 630 2.4 40.4 2.0 48.8 7110 300
A2-AY-1800 1 800 2.6 46.6 2.5 56.4 9390 340
A2-AY-10000 1 1000 2.8 50.6 2.5 60.6 11580 370
1:37
1POWER & WIRING CABLES
®
Number Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size (fixed bend)
mm2 mm mm mm mm kg/km mm
CONDUCTORS MAY BE CIRCULAR OR CIRCULAR COMPACTED.For further technical information refer to page 1:100. (See 1:114 for technical informationon 1900/3300V cables).
For conductor and armour resistances refer page 13:31.For Gross Cross-Sectional area of armour refer to page 13:34.For conductor short-circuit ratings refer to page 13:29.For armour short-circuit ratings refer to page 13:36.
1:38
POWER & WIRING CABLES1
®
Multi-Core XLPE/LSF/SWA/LSF Power &Control Cable 600/1000 and 1900/3300 Volts
• In accordance with BS6724.
• Conductors: Stranded Class 2 copper
conductors.
• Insulation: XLPE insulation Type
GP8 to BS7655.
• Core identification:
2 core - red, black
3 core - red, yellow, blue
4 core - red, yellow, blue, black
5 core + above - number printed
• Inner Sheath: LSF inner sheath
Type LTS1 to BS7655.
• Mild galvanised steel wires to BSEN10257-1
• Outer Sheath: Black LSF outer
sheath Type LTS1 to BS7655.
• Flame retardant to BS4066/IEC60332
Part 3 Category A (NMV7).
• Temp Rating: 900C max conductor
operating temperature.
• Voltage Rating: 600/1000 &
1900/3300V.
NB:1900/3300V only available in 3 core
LSF insulated, armoured and
sheathed, multi-core power cable.
Especially for use in areas where fire
would create dense smoke and toxic
fumes causing a major threat to life and
equipment.
A P P L I C A T I O N S P E C I F I C A T I O N S
600/1000V Cables
A2-AU-0015 2 1.5* 0.6 7.7 0.9 12.3 310 80
A2-AU-0025 2 2.5* 0.7 9.0 0.9 13.6 360 90
A2-AU-0040 2 4* 0.7 10.1 0.9 14.7 420 90
A2-AU-0060 2 6* 0.7 11.3 0.9 15.9 500 100
A2-AU-0100 2 10* 0.7 13.2 0.9 18.0 800 110
A2-AU-0160 2 16† 0.7 14.5 1.25 20.0 940 120
A2-AU-0250 2 25† 0.9 18.4 1.25 24.1 1250 150
A2-AU-0350 2 35† 0.9 21.3 1.6 27.9 1720 170
A2-AU-0500 2 50 \\ 1.0 19.0 1.6 25.8 1800 210
A2-AU-0700 2 70 1.1 22.0 1.6 29.0 2330 240
A2-AU-0950 2 95 1.1 25.1 2.0 33.1 3170 270
A2-AU-1200 2 120 1.2 27.9 2.0 36.1 3810 290
A2-AU-1500 2 150 1.4 30.9 2.0 39.3 4530 320
A2-AU-1850 2 185 1.6 34.9 2.5 44.7 5860 360
A2-AU-2400 2 240 1.7 39.0 2.5 49.0 7300 400
A2-AU-3000 2 300 1.8 43.3 2.5 53.3 8790 430
A2-AU-4000 2 400 2.0 48.4 2.5 59.0 10770 480
A2-AV-0015 3 1.5* 0.6 8.2 0.9 12.8 340 80
A2-AV-0025 3 2.5* 0.7 9.5 0.9 14.1 400 90
A2-AV-0040 3 4* 0.7 10.7 0.9 15.3 500 100
A2-AV-0060 3 6* 0.7 12.0 0.9 16.6 770 100
A2-AV-0100 3 10* 0.7 14.0 1.25 19.5 900 120
A2-AV-0160 3 16† 0.7 15.5 1.25 21.2 1180 130
A2-AV-0250 3 25† 0.9 20.1 1.6 26.7 1720 170
A2-AV-0350 3 35† 0.9 22.8 1.6 29.6 2130 180
A2-AV-0500 3 50 \\ 1.0 21.7 1.6 28.5 2380 230
A2-AV-0700 3 70 1.1 25.2 1.6 32.2 3150 260
A2-AV-0950 3 95 1.1 28.8 2.0 37.0 4320 300
A2-AV-1200 3 120 1.2 32.0 2.0 40.4 5200 330
A2-AV-1500 3 150 1.4 35.9 2.5 45.5 6630 370
A2-AV-1850 3 185 1.6 40.0 2.5 49.8 7980 400
A2-AV-2400 3 240 1.7 44.9 2.5 55.1 9960 450
A2-AV-3000 3 300 1.8 49.8 2.5 60.2 12060 490
A2-AV-4000 3 400 2.0 55.8 2.5 66.6 14980 540
1:39
1POWER & WIRING CABLES
®
Number Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size (fixed bend)
mm2 mm mm mm mm kg/km mm
*Circular stranded conductors.\\ Cables having conductors of nominal area 50mm2 and above have shaped stranded conductors.† Circular or circular compacted stranded conductors.
continued overleaf. . .
®
A2-AX-0015 4 1.5* 0.6 8.9 0.9 13.5 390 90
A2-AX-0025 4 2.5* 0.7 10.4 0.9 15.0 470 90
A2-AX-0040 4 4* 0.7 11.8 0.9 16.4 580 100
A2-AX-0060 4 6* 0.7 13.2 1.25 18.7 820 120
A2-AX-0100 4 10* 0.7 15.6 1.25 21.1 1060 130
A2-AX-0160 4 16† 0.7 17.2 1.25 22.9 1410 140
A2-AX-0250 4 25† 0.9 22.3 1.6 28.9 2090 180
A2-AX-0350 4 35† 0.9 25.3 1.6 32.1 2590 200
A2-AX-0500 4 50 \\ 1.0 25.0 1.6 32.0 2960 260
A2-AX-0700 4 70 1.1 29.5 2.0 37.7 4240 310
A2-AX-0950 4 95 1.1 33.3 2.0 41.7 5410 340
A2-AX-1200 4 120 1.2 37.5 2.5 47.1 6980 380
A2-AX-1500 4 150 1.4 41.6 2.5 51.4 8320 420
A2-AX-1850 4 185 1.6 46.4 2.5 56.6 10080 460
A2-AX-2400 4 240 1.7 52.6 2.5 63.0 12690 510
A2-AX-3000 4 300 1.8 58.0 2.5 68.8 15420 560
A3-03-C007 7 1.5* 0.6 10.6 0.9 15.2 490 100
A3-03-C012 12 1.5* 0.6 13.9 1.25 19.4 830 120
A3-03-C019 19 1.5* 0.6 16.5 1.25 22.2 1070 140
A3-03-C027 27 1.5* 0.6 20.1 1.6 26.7 1580 170
A3-03-C037 37 1.5* 0.6 22.4 1.6 29.2 1880 180
A3-P3-C007 7 2.5* 0.7 12.5 0.9 17.1 600 110
A3-P3-C012 12 2.5* 0.7 16.7 1.25 22.4 1020 140
A3-P3-C019 19 2.5* 0.7 20.0 1.6 26.6 1530 160
A3-P3-C027 27 2.5* 0.7 23.9 1.6 30.7 1960 190
A3-P3-C037 37 2.5* 0.7 27.0 1.6 33.8 2370 210
A3-Q3-C007 7 4* 0.7 14.2 1.25 19.7 830 120
A3-Q3-C012 12 4* 0.7 19.3 1.6 25.7 1440 160
A3-Q3-C019 19 4* 0.7 22.7 1.6 29.3 1930 180
A3-Q3-C027 27 4* 0.7 27.4 1.6 34.4 2530 210
A3-Q3-C037 37 4* 0.7 31.2 2.0 39.2 3470 240
1:40
POWER & WIRING CABLES1
Number Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size (fixed bend)
mm2 mm mm mm mm kg/km mm
Multi-Core XLPE/LSF/SWA/LSF Power &Control Cable 600/1000 and 1900/3300 Volts
. . . Continued
1:41
1POWER & WIRING CABLES
®
Number Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size (fixed bend)
mm2 mm mm mm mm kg/km mm
1900/3300V Cables
A2-AZ-0250 3 25† 2.0 25.4 1.6 32.2 2100 200
A2-AZ-0350 3 35† 2.0 28.0 1.6 35.0 2520 210
A2-AZ-0500 3 50\\ 2.0 26.7 2.0 34.7 3030 280
A2-AZ-0700 3 70 2.0 29.8 2.0 38.0 3810 310
A2-AZ-0950 3 95 2.0 33.0 2.0 41.4 4730 340
A2-AZ-1200 3 120 2.0 36.1 2.5 45.7 6020 360
A2-AZ-1500 3 150 2.0 38.7 2.5 48.5 6980 390
A2-AZ-1850 3 185 2.0 41.9 2.5 51.9 8250 420
A2-AZ-2400 3 240 2.0 46.7 2.5 56.9 10200 460
A2-AZ-3000 3 300 2.0 50.8 2.5 61.2 12210 490
A2-AZ-4000 3 400 2.0 55.8 2.5 66.6 15160 540
*Circular stranded conductors.\\ Cables having conductors of nominal area 50mm2 and above have shaped stranded conductors.† Circular or circular compacted stranded conductors.
For more technical information see page 1:106. (See 1:114 for technical informationon 1900/3300V cables).
For conductor and armour resistances refer page 13:32.For Gross Cross-Sectional area of armour refer to page 13:35.For conductor short-circuit ratings refer to page 13:29.For armour short-circuit ratings refer to page 13:37.
1:42
POWER & WIRING CABLES1
®
A P P L I C A T I O N S P E C I F I C A T I O N S
Three Core XLPE/LSF/SWA/LSF PowerCable 6.35/11kV
• In accordance with BS7835.
• Conductors: Stranded Class 2 copper
conductors to BS6360.
• Extruded semi-conducting layer.
• Insulation: XLPE insulation.
• Extruded semi-conducting layer.
• Plain copper tape screen.
• Inner Sheath: LSF inner sheath
Type LTS1 to BS7655.
• Mild galvanised steel wires to BSEN10257-1
• Outer Sheath: Red LSF outer sheath
Type LTS1 to BS7655.
• Flame retardant to BS4066 Part 3
Category A (IEC 60332 Part 3 Category A)
• Temp Rating: 900C max conductor
operating temperature.
• Voltage Rating: 6350/11000V
LSF armoured power cable for use in
fixed installations. Especially for use in
areas where fire would create dense
smoke and toxic fumes causing a
major threat to life and equipment.
For further technical information refer to page 1:118.
1:43
1POWER & WIRING CABLES
®
Number Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size mm
mm2 mm mm mm mm kg/km During AdjacentInstallation to joints and
No. Nominal Conductor Nominal Conductor Insulation Nom Approx Min Anixter of Conductor Class C.P.C. Class Thickness O/D Weight BendingPart No. Cores Area Area Radius
(fixed bend)mm2 mm2 mm mm kg/km mm
1:45
For further technical information see page 1:110.For white sheath add suffix -01, for red sheath add -03 to part number.
No. Nominal Nominal Nominal Nominal Insulation Nom Approx Min Anixter of Conductor Conductor C.P.C. C.P.C. Thickness O/D Weight BendingPart No. Cores Area Stranding Area Stranding Radius
(fixed bend)mm2 #/mm mm2 #/mm mm mm kg/km mm
For further technical information see page 1:110.For white sheath add suffix -01, for red sheath add -03 to part number.
1:50
POWER & WIRING CABLES1
®
Fire Resistant Armoured Power Cable 600/1000 Volts
• In accordance with BS7846.
• BASEC Approved.
• Conductors: Stranded Class 2 copper
conductors to BS6360.
• Mica/glass tape (S)
• Insulation: XLPE insulation type GP8
to BS7655.
• Core identification:
2 core - red, black
3 core - red, yellow, blue
4 core - red, yellow, blue, black
5 core + above - number printed
• Inner Sheath: LSF inner sheath
Type LTS1 to BS7655.
• Mild galvanised steel wires to BSEN10257-1
• Outer Sheath: Black LSF outer
sheath Type LTS1 to BS7655.
• Fire resistant to IEC60331 and
category CWZ of BS6387.
• Flame retardant to BS4066 Part 3
Category A (NMV7).• Meets BS7622 and IEC 61034 3m
cube smoke emission test.
• Temp Rating: 900C max conductor
operating temperature.
• Voltage Rating: 600/1000V
Armoured fire resistant cable for use in
fixed wiring installations where it is
necessary for the cable to retain circuit
integrity in the event of a fire, e.g. emergency
services, alarm systems, lighting, etc.,
and in situations where power must be
maintained to allow controlled
closedown of equipment.
A P P L I C A T I O N S P E C I F I C A T I O N S
A2EF-
020015-02 2 1.5* 0.6 8.6 0.9 13.4 313 90
020025-02 2 2.5* 0.7 9.9 0.9 14.6 384 90
020040-02 2 4.0* 0.7 11.1 0.9 15.8 434 100
020060-02 2 6.0* 0.7 12.2 0.9 16.9 505 110
020100-02 2 10* 0.7 14.1 0.9 19.1 808 120
020160-02 2 16† 0.7 16.3 1.25 21.3 949 130
020250-02 2 25† 0.9 19.3 1.25 24.6 1263 150
020350-02 2 35† 0.9 22.0 1.6 27.5 1737 170
020500-02 2 50// 1.0 20.0 1.6 27.0 1826 220
020700-02 2 70 1.1 23.0 1.6 30.3 2342 250
020950-02 2 95 1.1 25.5 2.0 33.8 3234 280
021200-02 2 120 1.2 28.5 2.0 37.0 4064 300
021500-02 2 150 1.4 31.2 2.0 40.0 4668 320
021850-02 2 185 1.6 35.0 2.5 45.0 5974 360
022400-02 2 240 1.7 39.5 2.5 50.0 7614 400
023000-02 2 300 1.8 44.0 2.5 54.5 8967 440
024000-02 2 400 2.0 49.0 2.5 60.0 10930 480
A2EF-
030015-02 3 1.5* 0.6 9.2 0.9 13.9 343 90
030025-02 3 2.5* 0.7 10.5 0.9 15.2 414 100
030040-02 3 4.0* 0.7 11.8 0.9 16.5 505 100
030060-02 3 6.0* 0.7 13.1 0.9 17.8 778 110
030100-02 3 10* 0.7 15.1 1.25 20.0 909 120
030160-02 3 16† 0.7 17.5 1.25 22.7 1192 140
030250-02 3 25† 0.9 21.2 1.6 26.7 1737 170
030350-02 3 35† 0.9 23.6 1.6 29.3 2151 180
030500-02 3 50 // 1.0 23.5 1.6 30.6 2516 250
030700-02 3 70 1.1 27.0 1.6 34.3 3273 280
030950-02 3 95 1.1 30.5 2.0 39.1 4513 320
031200-02 3 120 1.2 33.8 2.0 42.6 5533 350
031500-02 3 150 1.4 37.6 2.5 47.6 6912 390
031850-02 3 185 1.6 41.9 2.5 52.0 8306 420
032400-02 3 240 1.7 46.5 2.5 57.2 10504 460
033000-02 3 300 1.8 51.8 2.5 62.8 12431 510
034000-02 3 400 2.0 56.2 2.5 70.0 15280 560
1:51
1POWER & WIRING CABLES
®
No. Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size (fixed bend)
mm2 mm mm mm mm kg/km mm
Continued overleaf. . .
®
A2EF-
040015-02 4 1.5* 0.6 10.0 0.9 14.8 394 90
040025-02 4 2.5* 0.7 11.5 0.9 16.3 475 100
040040-02 4 4.0* 0.7 13.1 0.9 17.8 586 110
040060-02 4 6.0* 0.7 14.4 1.25 20.1 828 130
040100-02 4 10* 0.7 16.7 1.25 22.4 1071 140
040160-02 4 16† 0.7 19.3 1.25 25.2 1424 160
040250-02 4 25† 0.9 23.5 1.6 29.6 2111 180
040350-02 4 35† 0.9 26.2 1.6 32.6 2616 200
040500-02 4 50 // 1.0 26.4 1.6 33.7 3161 270
040700-02 4 70 1.1 30.6 2.0 39.1 4430 320
040950-02 4 95 1.1 34.4 2.0 43.2 5706 350
041200-02 4 120 1.2 38.4 2.5 48.4 7422 390
041500-02 4 150 1.4 42.6 2.5 52.9 8797 430
041850-02 4 185 1.6 47.1 2.5 57.8 10629 470
042400-02 4 240 1.7 53.5 2.5 64.5 13556 520
043000-02 4 300 1.8 59.0 2.5 69.9 15953 560
044000-02 4 400 2.0 65.9 2.5 79.9 20372 640
A2EF-
070015-02 7 1.5* 0.6 13.0 0.9 18.0 561 110
120015-02 12 1.5* 0.6 17.5 1.25 23.0 962 140
190015-02 19 1.5* 0.6 19.9 1.25 26.0 1217 160
270015-02 27 1.5* 0.6 24.5 1.6 31.0 1722 190
370015-02 37 1.5* 0.6 27.5 1.6 34.0 2132 210
1:52
POWER & WIRING CABLES1
Fire Resistant Armoured Power Cable 600/1000 Volts Continued. . .
No. Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size (fixed bend)
mm2 mm mm mm mm kg/km mm
®
A2EF-
070025-02 7 2.5* 0.7 13.9 0.9 18.5 638 120
120025-02 12 2.5* 0.7 18.0 1.25 24.0 1086 150
190025-02 19 2.5* 0.7 22.0 1.6 28.5 1641 180
270025-02 27 2.5* 0.7 26.5 1.6 33.5 2122 210
370025-02 37 2.5* 0.7 30.0 1.6 37.0 2605 230
A2EF-
070040-02 7 4.0* 0.7 15.5 1.25 21.0 922 130
120040-02 12 4.0* 0.7 21.0 1.6 27.0 1593 170
190040-02 19 4.0* 0.7 24.5 1.6 31.5 2076 190
270040-02 27 4.0* 0.7 30.0 1.6 37.0 2732 230
370040-02 37 4.0* 0.7 34.0 2.0 42.0 3751 260
1POWER & WIRING CABLES
1:53
*Circular stranded conductors.// Cables having conductors of nominal area 50mm2 and above will have shaped stranded conductors† Circular or circular compacted stranded conductors.
For more technical information refer to page 1:112.For conductor and armour resistances refer to page 13:32For gross cross-sectional area of armour refer to page 13:35For conductor short-circuit ratings refer to page 13:29For armour short-circuit ratings refer to page 13:37
Dimensions are based on Pirelli BS7846 Armoured cables.
NB: 25mm2 and 35mm2 cables may be supplied with SHAPED conductors. Detailson dimensions, weights etc available on request.
No. Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size (fixed bend)
mm2 mm mm mm mm kg/km mm
1:54
POWER & WIRING CABLES
®
Single Core XLPE/PVC Power Cable3.8/6.6, 6.35/11 and 8.7/15 kV
Power cable for use on fixed installations
Not suitable for direct burial.
• In accordance with BS6622.
• Conductors: Stranded Class 2 copper
conductors to BS6360.
• Extruded semi-conducting layer.
• Insulation: XLPE insulation.
• Extruded semi-conducting layer.
• Screen: Plain copper tape screen
• Outer Sheath: PVC outer sheath
Type 9 to BS7655.
• Flame retardant to BS4066 Part 1.
• Temp Rating: 900C max conductor
operating temperature.
• Voltage Rating: 3800/6600V,
6350/11000V, 8700/15000V
For black sheath add suffix -02, for red sheath -03.For further technical information refer to page 1:118.
A P P L I C A T I O N S P E C I F I C A T I O N S
1
1:55
1POWER & WIRING CABLES
®
Number Nominal Insulation Nom Approx Min BendingAnixter of Conductor Thickness O/D Weight RadiusPart No. Cores Area (mm) (mm) kg/km (fixed bend)
(mm2) During AdjacentInstallation to joints and
Termination
3800/6600V Cables
A2CJ-1050U 1 50 2.5 20.0 800 400 300
A2CJ-1070U 1 70 2.5 22.0 1000 440 330
A2CJ-1095U 1 95 2.5 23.7 1300 480 360
A2CJ-1120U 1 120 2.5 25.5 1600 510 390
A2CJ-1150U 1 150 2.5 26.8 1900 540 410
A2CJ-1185U 1 185 2.5 28.8 2200 580 440
A2CJ-1240U 1 240 2.6 31.2 2800 630 470
A2CJ-1300U 1 300 2.8 34.2 3500 690 520
A2CJ-1400U 1 400 3.0 37.7 4300 760 570
A2CJ-1500U 1 500 3.2 41.3 5400 830 620
A2CJ-1630U 1 630 3.2 44.9 6700 900 680
6350/11000V Cable
A2CT-1050U 1 50 3.4 22.2 900 450 340
A2CT-1070U 1 70 3.4 24.0 1100 480 360
A2CT-1095U 1 95 3.4 26.0 1400 520 390
A2CT-1120U 1 120 3.4 27.5 1700 550 420
A2CT-1150U 1 150 3.4 29.0 2000 580 440
A2CT-1185U 1 185 3.4 30.8 2400 620 470
A2CT-1240U 1 240 3.4 33.2 2900 670 500
A2CT-1300U 1 300 3.4 35.7 3500 720 540
A2CT-1400U 1 400 3.4 38.6 4400 780 580
A2CT-1500U 1 500 3.4 41.8 5400 840 630
A2CT-1630U 1 630 3.4 45.4 6800 910 690
8700/15000V Cables
A2DE-1050U 1 50 4.5 24.6 1000 500 370
A2DE-1070U 1 70 4.5 26.7 1200 540 410
A2DE-1095U 1 95 4.5 28.6 1500 580 430
A2DE-1120U 1 120 4.5 30.1 1800 610 460
A2DE-1150U 1 150 4.5 31.2 2100 630 470
A2DE-1185U 1 185 4.5 33.4 2500 670 510
A2DE-1240U 1 240 4.5 35.8 3100 720 540
A2DE-1300U 1 300 4.5 38.3 3700 770 580
A2DE-1400U 1 400 4.5 41.3 4600 830 620
A2DE-1500U 1 500 4.5 44.4 5600 890 670
A2DE-1630U 1 630 4.5 48.0 7000 960 720
1:56
POWER & WIRING CABLES1
®
Single Core XLPE/PVC /AWA/PVC PowerCable 3.8/6.6, 6.35/11 and 8.7/15 kV
Power cable for use on fixed installations,
indoor, outdoor or direct burial.
• In accordance with BS6622
• Conductors: Stranded Class 2 copper
conductors to BS6360.
• Extruded semi-conducting layer.
• Insulation: XLPE insulation.
• Extruded semi-conducting layer.
• Plain copper tape screen.
• Inner Sheath: PVC inner sheath
Type 9 to BS7655.
• Aluminium wires to BS2627.
• Outer Sheath: PVC outer sheath
Type 9 to BS7655.
• Flame retardant to BS4066 Part 1.
• Temp Rating: 900C max conductor
operating temperature.
• Voltage Rating: 3800/6600,
6350/11000, & 8700/15000V
For black sheath add suffix -02, for red sheath -03.For further technical information refer to page 1:118.
A P P L I C A T I O N S P E C I F I C A T I O N S
3800/6600V Cables
A2CJ-1050 1 50 2.5 18.9 1.6 25.7 1200 390 310
A2CJ-1070 1 70 2.5 20.7 1.6 27.5 1400 420 330
A2CJ-1095 1 95 2.5 22.4 1.6 29.4 1800 450 360
A2CJ-1120 1 120 2.5 23.9 1.6 30.9 2000 470 380
A2CJ-1150 1 150 2.5 25.2 1.6 32.4 2300 490 390
A2CJ-1185 1 185 2.5 27.0 2.0 35.0 2800 530 420
A2CJ-1240 1 240 2.6 29.4 2.0 37.6 3500 570 460
A2CJ-1300 1 300 2.8 32.4 2.0 40.8 4200 620 490
A2CJ-1400 1 400 3.0 35.5 2.0 44.1 5100 670 530
A2CJ-1500 1 500 3.2 39.0 2.5 49.0 6400 740 590
A2CJ-1630 1 630 3.2 42.6 2.5 52.8 7400 800 640
6350/11000V Cable
A2CT-1050 1 50 3.4 20.9 1.6 27.7 1300 420 340
A2CT-1070 1 70 3.4 22.7 1.6 29.7 1600 450 360
A2CT-1095 1 95 3.4 24.4 1.6 31.4 1900 480 390
A2CT-1120 1 120 3.4 25.9 1.6 33.1 2200 500 400
A2CT-1150 1 150 3.4 27.2 2.0 35.4 2600 540 430
A2CT-1185 1 185 3.4 29.0 2.0 37.2 3000 560 450
A2CT-1240 1 240 3.4 31.4 2.0 39.8 3600 600 480
A2CT-1300 1 300 3.4 33.7 2.0 42.3 4300 640 510
A2CT-1400 1 400 3.4 36.4 2.0 45.2 5200 680 550
A2CT-1500 1 500 3.4 39.5 2.5 49.5 6500 750 600
A2CT-1630 1 630 3.4 43.1 2.5 53.3 7900 800 640
8700/15000V Cables
A2DE-1050 1 50 4.5 23.3 1.6 30.3 1400 460 370
A2DE-1070 1 70 4.5 25.1 1.6 32.1 1700 490 390
A2DE-1095 1 95 4.5 26.8 2.0 34.8 2100 530 420
A2DE-1120 1 120 4.5 28.3 2.0 36.5 2400 550 440
A2DE-1150 1 150 4.5 29.6 2.0 37.8 2700 570 460
A2DE-1185 1 185 4.5 31.6 2.0 40.0 3200 600 480
A2DE-1240 1 240 4.5 33.8 2.0 42.4 3800 640 510
A2DE-1300 1 300 4.5 36.1 2.0 44.7 4500 680 540
A2DE-1400 1 400 4.5 39.0 2.5 49.0 5600 740 590
A2DE-1500 1 500 4.5 41.9 2.5 52.1 6700 790 630
A2DE-1630 1 630 4.5 45.5 2.5 55.9 8200 840 680
1:57
1POWER & WIRING CABLES
®
Number Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size mm kg/km mm
mm2 mm mm mm During AdjacentInstallation to joints and
Termination
A P P L I C A T I O N S P E C I F I C A T I O N S
1:58
POWER & WIRING CABLES1
®
Three Core XLPE/PVC Power Cable3.8/6.6, 6.35/11 and 8.7/15 kV
Multicore power cable for use on fixed
installations. Indoor or outdoor use.
Not suitable for direct burial.
• In accordance with BS6622
• Conductors: Stranded Class 2 copper
conductors to BS6360.
• Extruded semi-conducting layer.
• Insulation: XLPE insulation.
• Extruded semi-conducting layer.
• Plain copper tape screen.
• Sheath: PVC outer sheath Type 9 to
BS7655.
• Flame retardant to BS4066 Part 1.
• Temp Rating: 900C max conductor
operating temperature.
• Voltage Rating: 3800/6600,
6350/11000, & 8700/15000V
For black sheath add suffix -02, for red sheath -03 to part number.For further technical information refer to page 1:118.
1:59
1POWER & WIRING CABLES
®
Number Nominal Insulation Nom Approx Min BendingAnixter of Conductor Thickness O/D Weight RadiusPart No. Cores Area (fixed bend) mm
mm2 mm mm kg/km During AdjacentInstallation to joints and
Termination
3800/6600V Cables
A2CM-3016U 3 16 2.5 33.3 1300 500 400
A2CM-3025U 3 25 2.5 35.8 1700 540 430
A2CM-3035U 3 35 2.5 38.2 2000 580 460
A2CM-3050U 3 50 2.5 40.9 2600 620 500
A2CM-3070U 3 70 2.5 44.9 3300 680 540
A2CM-3095U 3 95 2.5 48.8 4200 740 590
A2CM-3120U 3 120 2.5 52.2 5000 790 630
A2CM-3150U 3 150 2.5 55.2 5800 830 670
A2CM-3185U 3 185 2.5 59.4 7100 900 720
A2CM-3240U 3 240 2.6 65.0 9000 980 780
A2CM-3300U 3 300 2.8 71.4 10900 1080 860
A2CM-3400U 3 400 3.0 78.8 13800 1190 950
6350/11000V Cable
A2CW-3016U 3 16 3.4 38.0 1700 570 460
A2CW-3025U 3 25 3.4 40.3 2000 610 490
A2CW-3035U 3 35 3.4 42.8 2400 650 520
A2CW-3050U 3 50 3.4 45.4 2900 690 550
A2CW-3070U 3 70 3.4 49.4 3600 750 600
A2CW-3095U 3 95 3.4 53.5 4500 810 650
A2CW-3120U 3 120 3.4 57.0 5400 860 690
A2CW-3150U 3 150 3.4 60.0 6300 900 720
A2CW-3185U 3 185 3.4 64.1 7500 970 770
A2CW-3240U 3 240 3.4 69.1 9300 1040 830
A2CW-3300U 3 300 3.4 74.5 11200 1120 900
A2CW-3400U 3 400 3.4 80.7 14000 1220 970
8700/15000V Cables
A2DH-3025U 3 25 4.5 46.0 2400 690 560
A2DH-3035U 3 35 4.5 48.4 2800 730 590
A2DH-3050U 3 50 4.5 50.9 3200 770 620
A2DH-3070U 3 70 4.5 55.0 4000 830 660
A2DH-3095U 3 95 4.5 59.0 5000 890 710
A2DH-3120U 3 120 4.5 62.4 5900 940 750
A2DH-3150U 3 150 4.5 65.4 6800 990 790
A2DH-3185U 3 185 4.5 69.5 8000 1050 840
A2DH-3240U 3 240 4.5 74.6 9900 1120 900
A2DH-3300U 3 300 4.5 80.1 11900 1210 970
A2DH-3400U 3 400 4.5 86.3 14600 1300 1040
A P P L I C A T I O N S P E C I F I C A T I O N S
1:60
POWER & WIRING CABLES1
®
Three Core XLPE/PVC/SWA/PVC PowerCable 3.8/6.6, 6.35/11 and 8.7/15 kV
• In accordance with BS6622.
• Conductors: Stranded Class 2 copper
conductors to BS6360.
• Extruded semi-conducting layer.
• Insulation: XLPE insulation.
• Extruded semi-conducting layer.
• Plain copper tape screen.
• Inner Sheath: PVC inner sheath
Type 9 to BS7655.
• Mild galvanised steel wires to BSEN10257-1
• Outer Sheath: PVC outer sheath
Type 9 to BS7655.
• Flame retardant to BS4066 Part 1.
• Temp Rating: 900C max conductor
operating temperature.
• Voltage Rating: 3800/6600,
6350/11000, & 8700/15000V
Multicore power cable for use on fixed
installations. Indoor or outdoor use, or
for direct burial.
For black sheath add suffix -02, for red sheath -03 to part number.For further technical information refer to page 1:118.
1:61
1POWER & WIRING CABLES
®
Number Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Under Wire O/D Weight RadiusPart No. Cores Area Armour Size mm
mm2 mm mm mm mm kg/km During AdjacentInstallation to joints and
Termination
3800/6600V Cables
A2CM-3016 3 16 2.5 31.3 2.0 39.7 2900 480 400
A2CM-3025 3 25 2.5 33.6 2.0 42.0 3300 510 420
A2CM-3035 3 35 2.5 35.8 2.0 44.4 3700 540 440
A2CM-3050 3 50 2.5 38.4 2.5 48.4 4900 590 490
A2CM-3070 3 70 2.5 42.2 2.5 52.4 5800 630 530
A2CM-3095 3 95 2.5 46.1 2.5 56.5 6900 680 570
A2CM-3120 3 120 2.5 49.5 2.5 60.1 7900 730 610
A2CM-3150 3 150 2.5 52.2 2.5 63.1 8900 760 640
A2CM-3185 3 185 2.5 56.4 2.5 67.4 10400 810 680
A2CM-3240 3 240 2.6 61.8 2.5 73.2 12700 880 740
A2CM-3300 3 300 2.8 68.0 3.15 81.3 16000 980 820
A2CM-3400 3 400 3.0 75.1 3.15 88.8 19400 1070 890
6350/11000V Cables
A2CW-3016 3 16 3.4 35.6 2.0 44.2 3400 540 450
A2CW-3025 3 25 3.4 38.1 2.5 47.9 4300 580 480
A2CW-3035 3 35 3.4 40.3 2.5 50.3 4700 610 510
A2CW-3050 3 50 3.4 42.9 2.5 53.1 5500 640 540
A2CW-3070 3 70 3.4 46.7 2.5 57.1 6400 690 580
A2CW-3095 3 95 3.4 50.6 2.5 61.2 7500 740 620
A2CW-3120 3 120 3.4 54.0 2.5 65.0 8600 780 650
A2CW-3150 3 150 3.4 56.8 2.5 68.0 9600 820 680
A2CW-3185 3 185 3.4 60.9 2.5 72.3 11200 870 730
A2CW-3240 3 240 3.4 65.9 3.15 79.0 14200 950 790
A2CW-3300 3 300 3.4 71.0 3.15 84.5 16500 1020 850
A2CW-3400 3 400 3.4 77.0 3.15 90.9 19700 1100 910
8700/15000V Cables
A2DH-3025 3 25 4.5 43.5 2.5 53.7 5000 650 540
A2DH-3035 3 35 4.5 45.7 2.5 56.1 5500 680 570
A2DH-3050 3 50 4.5 48.2 2.5 58.8 6100 710 590
A2DH-3070 3 70 4.5 52.1 2.5 62.9 7100 760 630
A2DH-3095 3 95 4.5 56.0 2.5 67.0 8300 810 670
A2DH-3120 3 120 4.5 59.4 2.5 70.6 9400 850 710
A2DH-3150 3 150 4.5 62.2 2.5 73.6 10500 890 740
A2DH-3185 3 185 4.5 66.3 3.15 79.4 12900 960 800
A2DH-3240 3 240 4.5 71.2 3.15 84.7 15200 1020 850
A2DH-3300 3 300 4.5 76.4 3.15 90.1 17600 1090 910
A2DH-3400 3 400 4.5 82.4 3.15 96.7 20800 1170 970
1:62
POWER & WIRING CABLES1
®
Three Core PILC/SWA/PVC Power Cable6350/11000 Volts "BELTED" M.I.N.D.
• In accordance with BS6480.
• Conductors: Stranded Class 2 copper
conductors to BS6360.
• 2 layers semi-conducting carbon
paper tapes.
• Insulating paper tape(s).
• Core identification:
white numbers on outer layer of
insulating paper(s).
• Paper belt.
• All insulation mass impregnated non
draining.
• Lead sheath to BS801
• 2 carbon papers + hessian tape
textile bedding.
• Mild galvanised steel wires to BSEN10257-1
• PVC outer sheath Type TM.1 to BS7655.
• Flame retardant to BS4066 Part 1.
• Temp Rating: 650C max conductor
operating temperature.
• Voltage Rating: 6350/11000 V
For fixed applications, supplying public
and industrial distribution systems.
Suitable for direct burial.
A P P L I C A T I O N S P E C I F I C A T I O N S
1:63
1POWER & WIRING CABLES
®
No. Nominal Insulation Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Over Wire O/D Weight RadiusPart No. Cores Area (mm2) (mm) Lead Size (fixed bend)
Between Between mm mm mm kg/km mmConductors Conductors
Multi-Core XLPE/LC/PVC/SWA/PVC Power& Control Cable 600/1000 Volts to EEMUA 133 Spec.
• In accordance with BS5467 and
EEMUA 133.
• Conductors: Stranded Class 2 copper
conductors to BS6360.
• Insulation: XLPE insulation Type
GP8 to BS7655.
• Core identification:
2 core - red, black
3 core - red, yellow, blue
4 core - red, yellow, blue, black
5 core + above - number printed
• Lead sheath to BS801.
• Inner Sheath: PVC inner sheath
Type 9 to BS7655.
• Mild galvanised steel wires to BSEN10257-1
• Outer Sheath: Black PVC outer
sheath Type 9 to BS7655.
• Flame retardant to BS4066 Part 1.
• Temp Rating: 900C max conductor
operating temperature
• Voltage Rating: 600/1000V
• Also available up to 11000V.
Lead sheathed power and control
cables for use underground where
cables may be subject to solvent
penetration or corrosive attack.
A P P L I C A T I O N S P E C I F I C A T I O N S
1:67
1POWER & WIRING CABLES
®
Number Nominal Insulation Diam Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Over Under Wire O/D Weight RadiusPart No. Cores Area Lead Armour Size (fixed bend)
mm2 mm mm mm mm mm kg/km mm
A2EB-0015Q 2 1.5* 0.7 8.5 10.1 0.9 14.5 690 180
A2EB-0025Q 2 2.5* 0.7 9.6 11.2 0.9 15.8 772 190
A2EB-0040 2 4* 0.7 10.6 12.2 0.9 16.8 883 210
A2EB-0060 2 6* 0.7 11.8 13.4 0.9 18.2 1001 220
A2EB-0100 2 10* 0.7 13.7 15.3 0.9 20.1 1227 250
A2EB-0160 2 16† 0.7 16.1 17.7 1.25 23.2 1565 280
A2EB-0250 2 25† 0.9 19.8 21.4 1.25 27.1 2094 330
A2EB-0350 2 35† 0.9 22.3 24.3 1.6 30.9 2868 380
A2EB-0500 2 50\\ 1.0 19.3 21.3 1.6 28.1 2783 340
A2EB-0700 2 70 1.1 22.1 24.1 1.6 31.1 3566 380
A2EB-0950 2 95 1.1 24.7 27.1 2.0 35.1 4678 430
A2EB-1200 2 120 1.2 27.9 30.3 2.0 38.5 5641 470
A2EB-1500 2 150 1.4 31.0 33.4 2.0 41.8 6660 510
A2EB-1850 2 185 1.6 34.5 37.3 2.5 47.1 8457 570
A2EB-2400 2 240 1.7 39.5 42.3 2.5 52.3 10286 630
A2EB-3000 2 300 1.8 43.3 46.5 2.5 56.7 12245 690
A2EB-4000 2 400 2.0 48.8 52.0 2.5 62.6 15077 760
A2EC-0015Q 3 1.5* 0.7 9.0 10.6 0.9 15.0 744 180
A2EC-0025Q 3 2.5* 0.7 10.1 11.7 0.9 16.3 842 200
A2EC-0040 3 4* 0.7 11.3 12.9 0.9 17.5 967 210
A2EC-0060 3 6* 0.7 12.6 14.2 0.9 18.8 1122 230
A2EC-0100 3 10* 0.7 14.6 16.2 1.25 21.7 1493 270
A2EC-0160 3 16† 0.7 17.1 18.7 1.25 24.4 1813 300
A2EC-0250 3 25† 0.9 21.1 23.1 1.6 29.7 2673 360
A2EC-0350 3 35† 0.9 23.8 25.8 1.6 32.6 3338 400
A2EC-0500 3 50 1.0 22.6 24.6 1.6 31.4 3572 380
A2EC-0700 3 70 1.1 26.2 28.2 1.6 35.2 4639 430
A2EC-0950 3 95 1.1 29.5 31.9 2.0 40.1 6023 490
A2EC-1200 3 120 1.2 32.8 35.2 2.0 43.6 7392 530
A2EC-1500 3 150 1.4 36.5 39.3 2.5 48.9 9242 590
A2EC-1850 3 185 1.6 40.7 43.5 2.5 53.3 11054 640
A2EC-2400 3 240 1.7 45.9 48.7 2.5 58.9 13792 710
A2EC-3000 3 300 1.8 50.5 53.7 2.5 64.1 16519 770
A2EC-4000 3 400 2.0 56.7 59.9 2.5 70.7 20331 850
*Circular stranded conductors.\\ Cables having conductors of nominal area 50mm2 and above have shaped stranded conductors.† Circular or circular compacted stranded conductors.
POWER & WIRING CABLES1 Multi-Core XLPE/LC/PVC/SWA/PVC Power
& Control Cable 600/1000 Volts
Continued. . .
Number Nominal Insulation Diam Diam Armour Nom Approx Min BendingAnixter of Conductor Thickness Over Under Wire O/D Weight RadiusPart No. Cores Area Lead Armour Size (fixed bend)
mm2 mm mm mm mm mm kg/km mm
*Circular stranded conductors.\\ Cables having conductors of nominal area 50mm2 and above have shaped stranded conductors.† Circular or circular compacted stranded conductors.
For more technical information see page 1:106.For conductor short-circuit ratings refer to page 13:29.
1:69
1POWER & WIRING CABLES
®
NB. Cables up to and including 16mm2 conductor size may be supplied with anextruded bedding under the lead sheath, leading to a variance in dimension andweights from those given. Details available upon request
POWER & WIRING CABLES
®
12kV PE/PVC Airfield Lighting Cable
For use in underground installations for
airfield lighting.
• In accordance with D.O.E.
(Department of the Environment)
Spec M&E 42 and BAA (British
Airports Authority) Spec *
ENG/2505/CEE 2kV only.
• Conductors: Stranded Class 2 copper
conductors to BS6360.
• Insulation: Polythene insulation Type
03 to BS6234.
• Sheath: PVC sheath Type TM.1 to
BS7655.
• Flame retardant to BS4066 Part 1.
• Various colours available upon
request.
• Temp Rating: 700C max conductor
operating temperature.
• Voltage Rating: 2000V/3300V/5000V.
* Embossing will state either M&E spec. or BAAspec. Standard stock is M&E spec.
*Circular stranded conductors//Cables having conductors on nominal area of 25mm² and above have shapedstranded conductorsFor further technical information see page 1:130
Recommended by ABB for use on their ACS 600 & ACV range of frequencyconverters.
1POWER & WIRING CABLES
1:75
1:76
POWER & WIRING CABLES1
®
A P P L I C A T I O N S P E C I F I C A T I O N S
XVB-F2 Multicore Power Cable600/1000V XLPE/PVC 900C
XVB-F2 power cables are suitable for
use indoor, in cable ducts, etc. in
industrial and power plant applications.
For applications where mechanical
damage is not envisaged.
• In accordance with NBN-IEC502-NAD
• Conductors: Solid Class 1 (RE) or
stranded Class 2 (RM) to VDE 0295
(equivalent to IEC60228 and BS6360).
• Insulation: XLPE insulation Type
GP8 to BS7655/IEC 60502 Table 7.
• Core Identification:
2 core - blue, brown
3 core - green/yellow, blue, brown
4 core - green/yellow, blue, brown,
black
5 core + above - green/yellow +
remaining cores black insulation with
white printed numbers
• Outer Sheath: Grey (RAL7001) PVC
Type 9 to BS7655 and Type ST2 to
IEC60502
• Flame retardant to BS4066/IEC60332
Part 3 Category C (NMV1.5), VDE0472
Part 804 Test C and F2 compliant as
per NBN C30-004.
• Temp Rating: 900C max conductor
operating temperature.
• Voltage Rating: 600/1000V
1:77
1POWER & WIRING CABLES
®
Number Nominal Conductor Insulation Nom Approx Approx Min BendingAnixter of Conductor Class Thickness O/D Copper Cable RadiusPart No. Cores Area Weight Weight (fixed bend)
mm2 mm mm kg/km kg/km mm
B1FE-
020015-09 2 1.5 1 (RE) 0.7 9.0 29 118 50
020025-09 2 2.5 1 (RE) 0.7 9.9 48 155 50
030015J-09 3 1.5 1 (RE) 0.7 9.4 43 134 50
030025J-09 3 2.5 1 (RE) 0.7 10.3 72 177 60
040015J-09 4 1.5 1 (RE) 0.7 10.2 58 158 60
040025J-09 4 2.5 1 (RE) 0.7 11.2 96 215 60
040040J-09 4 4.0 1 (RE) 0.7 12.6 154 300 80
040060J-09 4 6.0 2 (RM) 0.7 13.8 230 393 90
040100J-09 4 10 2 (RM) 0.7 16.0 384 591 100
040160J-09 4 16 2 (RM) 0.7 20.2 614 936 130
040250J-09 4 25 2 (RM) 0.9 24.7 960 1432 150
050015J-09 5 1.5 1 (RE) 0.7 11.2 72 194 60
050025J-09 5 2.5 1 (RE) 0.7 12.1 120 255 80
050040J-09 5 4.0 1 (RE) 0.7 13.7 192 359 90
050060J-09 5 6.0 2 (RM) 0.7 15.0 288 450 90
050100J-09 5 10 2 (RM) 0.7 17.4 480 714 110
050160J-09 5 16 2 (RM) 0.7 22.3 768 1147 140
050250J-09 5 25 2 (RM) 0.9 27.3 1200 1760 170
070015J-09 7 1.5 1 (RE) 0.7 12.2 101 240 80
070025J-09 7 2.5 1 (RE) 0.7 13.3 168 323 80
For further technical information see page 1:132
For conductor short-circuit ratings refer to page 13:29
For further technical information see page 1:135 of the cable handbook
For conductor short-circuit ratings refer to page 13:29 of the cable handbook
POWER & WIRING CABLES
1
1:79
1:80
POWER & WIRING CABLES
®
1
Conductor Reference Method 4 Reference Method 3 Referenced Method 1cross (enclosed in conduit (enclosed in conduit ("clipped direct")
Sectional in thermally on a wall or inarea insulating wall etc.) trunking etc.)
2 cables, 3 or 4 2 cables, 3 or 4 2 cables, 3 or 4single- cables single- cables single- cablesphase three- phase three- phase three-a.c or phase a.c. a.c or phase a.c. a.c or phase a.c.d.c. d.c. d.c. flat and
For further guidance refer to 16th Edition of IEE Wiring regulations.* With or without protective conductor.
POWER & WIRING CABLES
1
CAPACITY (Amperes)
1:85
1:86
POWER & WIRING CABLES
®
1
Standard depth of laying 0.5mThermal resistivity of soil 1.20C m/WStandard ground temperature 150CAmbient air temperature 250CMaximum conductor temperature 700C
Conductor Current Rating Voltage DropSize Single Phase a.c. Single Phase a.c.
In Single-Way Directmm2 Ducts Burial Air mV/A/m
4 44 53 42 11.0
6 55 66 54 7.2
10 73 88 74 4.3
16 96 115 97 2.7
25 125 150 130 1.7
35 150 185 160 1.2
Technical Information• Single Phase, Straight & Split Concentric
CURRENT CARRYING CAPACITY (amperes) &VOLTAGE DROP (per ampere per metre):
Conductor Current Rating Voltage DropSize Three Phase a.c. Three Phase a.c.
In Single-Way Directmm2 Ducts Burial Air mV/A/m
16 80 98 83 2.4
25 105 130 110 1.5
CURRENT CARRYING CAPACITY (amperes) &VOLTAGE DROP (per ampere per metre):
• Three Phase, Straight Concentric
1:87
1POWER & WIRING CABLES
®
For ambient air and ground temperatures other than those specified, the following
rating factors should be applied:
Cables Laid in Air
Ambient air temperature 0C 25 30 35 40 45 50 55
Rating factor 1.0 0.94 0.88 0.82 0.75 0.67 0.58
Cables Laid Direct in Ground and in Single-Way Ducts
Technical Information• Multicore PVC/PVC/SWA/PVC (694*) 600/100V• Multicore ESI 09-6 600/1000V
1:92
POWER & WIRING CABLES
®
1
C U R R E N T - C A R R Y I N G
Technical Information• Single Core LSF• Single Core XLPE/PVC (6181) Types 600/1000 Volts
Conductor Reference Method 4 Reference Method 3 Referenced Method 1cross (enclosed in conduit (enclosed in conduit ("clipped direct")
Sectional in thermally on a wall or inarea insulating wall etc.) trunking etc.)
2 cables, 3 or 4 2 cables, 3 or 4 2 cables, 3 or 4single- cables single- cables single- cablesphase three- phase three- phase three-a.c or phase a.c. a.c or phase a.c. a.c or phase a.c.d.c. d.c. d.c. flat and
1Technical Information• Single core XLPE/PVC 600/1000V to BS7889• Single core PCU/XLPE/PVC/AWA/PVC 600/1000V to BS5467• Single core PCU/XLPE/LSF/AWA/LSF 600/1000V to BS6724
ELECTRICAL CHARACTERISTICS
Conductor Max DC Max AC conductor Reactance @ 50Hz Impedance @ 900C, 50HzSize conductor resistance
resistance @ 900C Single core cables Single core cables@200C in trefoil in trefoil
Conductor operating temperature 900CNB. for ambient air and ground temperatures other than those specified the followingrating factors should be applied:
Cables Laid in AirAmbient air temp 0C 25 30 35 40 45 50 55Rating factor 1.0 0.96 0.92 0.88 0.83 0.78 0.73
1:109
1POWER & WIRING CABLES
®
Technical Information• Multicore PCU/XLPE/PVC 600/1000V to BS5467• Multicore PCU/XLPE/PVC/SWA/PVC 600/1000V to BS5467• Multicore PCU/XLPE/LSF/SWA/LSF 600/1000V to BS6724• Multicore PCU/XLPE/LC/PVC/SWA/PVC 600/1000V
ELECTRICAL CHARACTERISTICSConductor Max DC Max AC Reactance Impedance
For further guidance refer to 16th Edition IEE Wiring Regulations and ERA 69-30Part 5.For ambient air and ground temperatures other than those specified, the followingfactors should be applied,
Also applicable to LSF sheathed versions to BS7835
1:123
1POWER & WIRING CABLES
®
1:124
POWER & WIRING CABLES
®
1Technical Information• Three Core PILC/SWA/PVC Power Cable6350/11000V, "Belted"
Laid Direct in In Single-Way Ducts In Air
Nom Area the ground
of Conductor Armoured Armoured Armoured
mm2 A A A
16 89 76 80
25 115 99 105
35 140 120 130
50 165 140 155
70 205 175 195
95 245 210 240
120 280 240 275
150 315 265 315
185 355 300 360
240 410 355 425
300 460 395 490
400 520 445 560
Standard depth of laying 0.8mThermal resistivity of soil 1.20C m/WStandard ground temperature 150CAmbient air temperature 250CMaximum conductor temperature 650C
CURRENT CARRYING CAPACITY (Amperes)
1:125
1POWER & WIRING CABLES
®
For further guidance refer to 16th Edition IEE Wiring Regulations.
NB: High voltage cables are not specifically covered in IEE Wiring Regulations but
reference should be made to ensure compliance.
For ambient air and ground temperatures other than those specified, the following
factors should be applied.
Cables Laid in Air
Ambient air temperature 25 30 35 40 45
Rating factor 1.0 0.93 0.85 0.77 0.68
Cables Laid Direct and in Single-Way Ducts
Ground Temperature 0C 10 15 20 25 30
Rating Factor 1.05 1.0 0.95 0.89 0.84
1:126
POWER & WIRING CABLES
®
1Technical Information• Three core PCU/PILC/SWA/PVC 6350/11000V “Belted” to BS6480
ELECTRICAL CHARACTERISTICSConductor Max DC Max AC Reactance Impedance
Standard depth of laying 0.7mThermal resistivity of soil 1.0°C m/WStandard ground temperature 15°CAmbient conductor temperature 25°CMaximum conductor temperature 70°C