Conductors of extra fine wires to international standards to ensure maximum flexibility. Insulation allows conductor temperature of
90 degrees C and is extremely flexible NBR Elastomer Special jacket of outstanding toughness and
flexibility, resistance to acid, solvents and oil at extreme temperatures [see detailed properties chart of NBR Elastomer] UV stabilised and flame retardant.
Temperature Range:
Rated Voltage
Maximum Conductor Temperature:
Bending Radius Fixed:
Available Colors:
*-30 to + 90 degrees C static -20 to +90 degrees C flexible
:* 0.6/1Kv Relevant Standards: * VDE 0250, AS 3116, AS 1995, IEC 332-3
* 90 Degrees C
* 5 times diameter of the cable
***Orange, Black, Red, & Blue ******Add to Part No When Ordering***
* Tinned Stranded Conductors According to VDE 0295 Class 5 * EPR Rubber Insulation Type 3G13 * CPE Rubber Outer Sheath * UV stablised and flame retardant. * Resistant to oil and abrasion * Submersible to 100 Mts
Temperature Range:
Rated Voltage:
Conductor Temperature:
Bending Radius:
Available Colours:
*-40 to + 110 degrees C static -20 to +90 degrees C flexible
* 1.9/3.3Kv Relevant Standards: * VDE 0250 Part 602, AS 3116, AS3008, AS1125 Maximim
* 110 Degrees C
* 4 times diameter of the cable Static 6 Times Flexing
* Black
TYPICAL USES:
Power
Automotive
Welding
Switchboards, flexible droppers from bus bars, generators, load banks or anywhere SingleDouble insulated flexible cables are recommended
Battery leads, wiring looms, battery chargers, electric fork lifts.
* Conductors of extra fine wires to international standards to ensure maximum flexibility.
* Insulation allows conductor temperatures of 90 degree C & is extremely flexible special TPE compound.
*
Temperature Range
Typical Uses
Static - 30 to + 90 degree CFlexible -20 to + 90 degree C
Power: Switchboards, Flexible droppers from busbars flexible links, transformers, generators, load banks, or anywhere green/yellow flexible earth cables are to be used. Welding earth leads.
eNBR Rubber Elastomer Insulated and Sheathed High Flex Power and Control CablesHeavy Duty 0.6/1kV Ordinary Duty 250/440V
Cable Construction*Conductors: annealed fine wires of plain electrolytic copper stranded for high flexibility.*Insulation of special flame retardant NBR Elastomer compound formulated for high flexibility & durable operation in extreme temperatures.*Separator or bedding of extruded or taped NBR material. Silicated powder lubricant between cores & inner sheath to reduce friction.*NBR Elastomer for outstanding flexibility & durability in most hostile environments.*UV Stabilised & fire retardant.
Temperature Range
-30 to +90 degree C static-20 to +90 degree C flexible
Bending Radius5 times diameter - fixed6 times diameter - flexible
Rated VoltageO.D HD.250/440V 0.6/1kV
Maximum Conductor Temperature
Relevant Standards
Applications
90 degree C
AS3147, AS3191, IEC227, IEC332.1
In machine tools, construction & engineering equipment, conveyors & other industrial application where outstanding flexibility is required under tough climatic & mechanical conditions. Diesel powered generator sets, load banks, ship to shore cables.
*Copper conductors [tinned up to 16 sq mm],acc.to VDE 0295, CLASS 5;*PETP-tape [only for sections above 16 sq,mm]*EPR rubber insulation type E14 acc. to HD22;*Elastomeric outer sheath type EM2 acc to HD222
*Minimum permissible ambient temperature - 40degrees Cel*Maximum permissible short circuit temperature250 degrees Cel*Minimum ambient temperature for optimum fullyflexible operations - 25 degrees C
The following minimum bending radius should be observed to ensure operating reliability.* For fixed installation - 4 x cable Diameter* When freely flexing - 5 x cable Diameter* For drag chains & reels - 10x cable Diameter
* Good tensile strength, tearing strength & abrasionresistance* Good elongation at breaks* Good dialectical properties * Acid resistant
Properties [cont]
Voltage Rating
Applications
Colour Code
* Oil resistant* Resistant to environmental factors like oxidation, ozone, sunlight* Flame retardant* Very good behavior to variations of outdoor temperature
* Rated Voltage UO/U = 0.6/1kv* Maximum operating voltages in: 3 phase AC Operation UO/U = 0.7/1.15kV DC operation UO/U=0.9/1.73kV * The cable is designated 450/750V with E14 insulation compound in accordance with VDE/IEC and meets or exceeds the Australian Standards AS3116 for the voltage rating of 0.6/1kV, R-EP-90
* For medium level mechanical loads, for use in dry & damp locations, for outdoor use or in locations subject to explosion hazards,* For industrial & workshop equipment* For connections of mobile machines & engines on construction sites,* As fixed installation, for example as installation on plaster in temporary buildings
Please refer to Australian Standards for full conditions and notes which refer to this table
Please Refer to NoremakFor More Information On Larger Sizes And Options
AS 3008.1.1 1998 Table 13 Fixed Table 15 Flexing
Flexible Power Cables
A1 A14
Quick Reference
Current Capacities Page A21Gland Options Page F9
Nor
mak
eFlexible Control PVC/NBR 0.3/0.5kV
Cable Construction
Temperature Range
Rated Voltage
*Conductors annealed fine wires of plain electrolytic copper stranded for high flexibility.
PVC Insulated
Cores: white insulated with sequential black numbers, 1green/yellow
Protective sheath of flame retardant NBR Elastomer for outstanding flexibility & durability in most hostile environments.UV stabilised & flame retardant
Screening if applicable will be tinned copper braid. 85% minimum coverage. Suitable for protection against EMI Radiation
Static - 30 to + 80 degree CFlexing -5 to + 70 degree C
Current Capacities Page A20Multi Core Deratings A21
Gland Options Page F8, F9 And F10
Nor
mak
eFlexible Control PVC Screened 0.3/0.5Kv
Cable Construction
Temperature Range
Rated Voltage
Conductor Stranding
*Fine wires Strands of bare copper wire, PVC core insulation, cores twisted in layers, black with consecutive numbering in white. One green yellow earth core. Outer sheath of PVC Compound
Static - 30 to + 70 degree CFlexing -5 to + 70 degree C
*Conductor fine wire strands of plain electrolytic copper wire for improved flexibility.
*Insulation made of NBR elastomer compound specially designed for resistance to migration & cold flexibility.
*Inner sheath of specially formulated PVC, resistant to migration & highly flexibile in sub-zero temperatures.
*Silicate powder lubricant between cores & inner sheath to reduce friction
TEMPERATURE RANGE:
RATED VOLTAGE
RELEVANT STANDARDS
BENDING RADIUS
APPLICATIONS
* - 30 TO + 90 Degree C static
* - 18 TO + 90 Degree C flexible
*0.6/1Kv
AS3147,IEC92-3,IEC92-353,IEC92-350,IEC332-3
15 X DIAMETER
As power, control or signal cable on inland waterway & sea-going vessels. On conveyors, machine tools, cranes, earth moving equipment & other industrial applications where extra mechanical protection is required. Also suitable for wiring in hazardous locations [i.e chemical plants]
PartNo
7777031577770415777705157777071577771215
777703257777042577770725
No of Cores xSection mm
square
3x1.54x1.55x1.57x1.5
12x1.5
3x2.54x2.57x2.5
Stranding
48/0.2148/0.2148/0.2148/0.2148/0.21
80/0.2180/0.2180/0.21
ApproxOuter Dia
mm
12.813.614.515.718.0
14.215.217.5
ApproxWeightKg/Km
220261271330504
260295448
Metal GlandSWA Type
MGSWA20-16MGSWA20-SMGSWA20-SMGSWA20MGSWA20
MGSWA20-SMGSWA20-SMGSWA20
Flexible Power Cables
A1 A18
Quick Reference
Current Capacities Page A21Gland Options Page F9-F10
Nor
mak
eParallel Twin Flexible Cable0.6/1kV
Cable Construction
*Conductors of fine strands of electrolytic copper wire for extra flexibility.
*Insulation of cores in red/black or Red/ Blue Aflex NBR elastomer
*Compound specially formulated for improved cold resistance.
*Sheathing of transparent PVC compound resistant to cold, abrasion, industrial oil and chemicals
*UV stabilised and flame retardant
Temperature Range:
Rated Voltage:
Relevant Standards:
Application:
*-30 to + 75 degrees C static -20 to +75 degrees C flexible
* 0.6/1Kv fixed wiring 450/750v for flexing
* VDE 0250, VDE472, AS3147, IEC 332-1
* Battery cable for use indoors and outdoors, in dry as well as wet locations on motorised vehicles, or battery powered equipment such as fork lifts, field conveyors etc. Also in high quality booster cables.
Current Capacities Page A21Gland Options Page F8, F9, F10
Nor
mak
eSubmersible EPR/PUR Flexible Cables
Construction
Insulation:
Outer Sheath;
Core Colour
* Copper Conductor: Flexible, tinned up to 16mmsq Flexible, bare from 25mmsq upwards [acc. to IEC 228 Class 5 resp. Class 6 for single -core cables]
EPDM, compound type Ei6 ass. to HD 22.1 S2* Filling sheath: Halogen-free filling compound [except single-core cables]
Halogen free polyurethane, compound type TMPU acc. to HD 22.10 S1* Screening if applicable will be tinned copper braid. Pilot cores will be 1.5 mmsq Sheath colour * Orange [similar to RAL 2003]
*2 core : brown, blue*3 Core : brown, blue green/yellow*4 Core : black, blue, brown, green/yellow*5 Core : black,blue brown,blackgreen/yellowFrom 7Core-: black with numbers,green-yellow
* Extreme mechanical resistance [Abrasion-,tearing,-notch-,pressure & wear resistant]* Good reversed bending strength [min. 30000 reversed bendings under current acc. to VDE 0472, Part 603, Test H]* Good chemical resistance [against fuels, oils, grease, chemicals & sewage]* Resistant against enviromental factors[as ozone, UV, humidity, water]* Resistant against important temperature fluctuations* Flame retardant, halogen-free* Submersible down to 500m* Microbe & hydrolysis resistant
H05 BQ-F 300/500 V R-EP-90 Relvent Standard AS3191
HO5 BQ-F 300/500VAccording to CENELEC HD 22.10 S1
07 BQ-F AS3116 0.6/1KvAdapted to CENELEC HD22.10 S1
Flexible Power Cables
A1 A20
Quick Reference
Current Capacities Page A21Gland Options Page F8, F9, F10
Nor
mak
eSubmersible EPR/PUR Flexible Cables
PartNo
7773021577733G1577733G2577733G4
77734G1577734G2577734G477734G6
77735G1577735G2577735G477735G6
77735G1077735G16
77735G02577735G3577735G50
77737G1577737G25
No ofCores
x-sectionmm sq
2 x 1.53 x 1.53 x 2.53 x 4
4 x 1.54 x 2.54 x 44 x 6
5 x 1.55 x 2.55 x 45 x 6
5 x 105 x 165 x 255 x 355 x 50
7 x 1.57 x 2.5
MaxDia
Strandsmm
0.260.260.260.31
0.260.260.310.31
0.260.260.310.310.410.410.410.410.41
0.260.26
Approx OverallDia mm
9.09.511.013.0
10.512.514.014.0
11.513.516.018.023.126.533.538.043.5
14.016.5
ApproxWeightKg/Km
111130191266
162238331453
195291411559951
1351216929233945
291431
Maximum Amps
Protected from Sun
24243445
20283848
202838486688
120145180
1318
Nylon Gland
Part No
NGM16NGM20NGM20NGM25
NGM20NGM25NGM25NGM25
NGM20NGM25NGM25NGM32NGM40NGM40NGM50NGM63
-
NGM25NGM32
Metal GlandIP66
MG20-SMG20-SMG20MG20
MG20MG20MG25MG25
MG20MG25MG25MG25MG32MG40
MG50-SMG50MG50
MG25MG25
Metal Gland IP68
MGS20MGS20MGS20MGS25
MGS20MGS20MGS25MGS25
MGS20MGS25MGS32MGS32MGS40MGS40MGS50MGS63
-
MGS25MGS32
H07 BQ-F R-EP-90 Relevent Standard AS3191, AS3116 0.6/1Kv
HO5 BQ-F 300/500VAccording to CENELEC HD 22.10 S1
07 BQ-F AS3116 0.6/1KvAdapted to CENELEC HD22.10 S1
Flexible Power Cables
A21
Nor
mak
eTechnical Information
For Flexible Cables
Limiting Temperatures For Insulated Cables
Insulation Types
Thermoplastic
Elastomer
Cross Linked Polyethylene (XLPE)
Conductor Size mm
0.500.751.00
1.502.504.00
Conductor
Size mm
6.010.016.0
25.035.050.0
70.095.0
120.0
150.0185.0240.0*
446081
110135160
205240280
320360425
547499
135165195
250290340
390440510
344660
8095110
140160185
215240275
435877
105125145
185210245
280315365
Number Of Layers
1
2
3
4
Current Carrying Capacity Amps
3.0 (Conditions Apply)7.5
10.0
15.020.025.0
Derating Factor
0.76
0.58
0.47
0.40
Insulation Types
V-75 and HFI-75-TPV-90 and HFI-90-TP (AS 3008.1.1 For Conditions)
V90 HT (AS 3008.1.1 For Conditions)
R-EP-90, R-CPE-90, R-HF-90 and R-CSP-90R-HF-110 and R-E-110
X-90 and X-HF-90X-HF-110
Normal Use
757575
90110
90110
Flexible Power Cables
A1 A22
Max Permissible
7590
105
90110
90110
Operating Temperatures Of Conductors C
0
Current Carrying Capacities Of Flexible Cords Derating For Cords Wound On a Drum 0.5-4.0mm
2
2
Single And 2 Core
V75, V90
Single And 2 Core
R-EP-90R-CSP-90
Single And 2 Core
V75, V90
Single And 2 Core
R-EP-90R-CSP-90
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Current Carrying Capacities of 0.6/1 kV Flexible CablesProtected From Sun Exposed To Sun
Based On Ambient Air Temperature of 25 C0
2
Ratings and Capacities are based on Flexible Cables used In Flexing Applications and NOT Flexible Cables usedfor Fixed wiring applications. Refer to Australian Standards for these ratings AS 3008.1.1
S3
1 1
5A
00
8.1
.9
98
Ta
ble
1
S3
01
19
9T
6A
08
.1.
8
ab
le1
AS
30
08
.1.1
19
98
Ta
ble
1
Nor
mak
e
Flexible Power Cables
A23
Technical InformationFor Flexible Cables
Conductor
Size mm
6.010.016.0
25.035.050.0
70.095.0
120.0
150.0185.0240.0*
Conductor
Size mm
0.500.751.001.502.504.006.00
10.0016.0025.0035.00
385270
95115140
175205240
280315370
19242837506787
120165215265
466385
115140165
215250290
335380445
1520232838506790119160194
293951
688196
120140160
185205235
15202431435874
105140185230
375066
88105125
155180210
240270310
131619243242557699
135163
2
2
3 And 4 Core
V75, V90
3 And 4 Core
R-EP-90R-CSP-90
3 And 4 Core
V75, V90
3 And 4 Core
R-EP-90R-CSP-90
Exposed To SunProtected From Sun
Current Carrying Capacities of 0.6/1 kV Flexible Cables
Current Carrying Capacities of R-S-150 Flexible Cords
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Two Single Core Or One 2 CoreThree or Four Single Core
or 3 or 4 core
Number Of Cores
57
101419244061
Laying In air
0.750.650.550.500.450.400.350.30
Laying In Ground
0.700.600.500.450.400.350.300.25
AC Derating Factors For Multi Core Cables Greater Than 5 Core 1.5 To 10.0 mm
2
S3
1 1
5A
00
8.1
.9
98
Ta
ble
1S
1 1
7A
30
08
.1.
99
8 T
ab
le1
Nor
mak
eTechnical Information
For Flexible Cables
Flexible Power Cables
A1 A24
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
AC Resistance At 50 Hz Of Flexible Cables And Cords With Copper Conductors
For AC Resistance Of Tinned Copper Conductors Multiply Copper Value By 1.01
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Nor
mak
e
Flexible Power Cables
A25
Technical InformationFor Flexible Cables
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Current Carrying Capacities of 3 Single Core 0.6/1 kV Flexible Cables R-EP-90 InsulationAs Per AS/NZS 3008.1.1:1998 Table 7
Single Double Insulated Cables InFixed Application
ConductorSize mm
11.52.546
10162535507095
120150185240300400
Spaced
192535465981110145180220280350410470550660770900
Spaced from
Surface
16213040506992
125155190240300350405470560650760
Touching
16202837476586115145175225280325375435520600700
Non-metallic wiring
enclosure in air
14182533425878110125155190230270310355420485560
Please refer to Australian Standards for full conditions and notes which refer to this table
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Nor
mak
eConductorSize mm
11.52.546
10162535507095
120150185240300400
Spaced
243143577399
130175220265340420490570660790910
1070
Spaced from
Surface
212738506386115155190230290365420485560670780910
Touching
202536475981
105145175215270340395455530630730850
Non-metallic wiring
enclosure in air
17223241517193
125150180235285335380450550630720
Current Carrying Capacities of 3 Single Core 0.6/1 kV Flexible Cables R-E-110 InsulationAs Per AS/NZS 3008.1.1:1998 Table 8
Single Double Insulated Cables InFixed Application
Please refer to Australian Standards for full conditions and notes which refer to this table
Technical InformationFor Flexible Cables
Flexible Power Cables
A1 A26
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Nor
mak
e
Flexible Power Cables
A27
Technical InformationFor Flexible Cables
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Application: Touching Mounted to Tray etc
ConductorSize mm
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
(1)V75, V90
13
16
23
31
40
54
72
97
120
145
185
230
265
310
355
425
490
570
(2)R-EP-90
16
20
28
37
47
65
86
115
145
175
225
280
325
375
435
520
600
700
(3)R-E-110
20
25
36
47
59
81
105
145
175
215
270
340
395
455
530
630
730
850
Please refer to Australian Standards for full conditions and information for the above ratings
Comparison of Current Ratings for Sheath Types As Per Australian Standards
Nor
mak
eThis catalogue only covers the standard range of cables supplied by Noremak Industries. Noremak can have cables manufactured custom cables for the Australian electronics industry with many of theseproducts being used locally and exported on a world wide
Noremak is capable of having products and cables manufactured to AS9002 and to Australian Standards including Austel, and can provide cables to UL approval for those cables involved in export manufacturing.
Noremak Industries has a close relationship with many cable manufacturesin Australia and overseas and is able to have special purpose cablesmanufactured to requirements and specialises in small run quantities.
These cables can be composed of any mixtures of conductors, pairs,coaxial cables and a variety of strength members and other elementsdepending on application
A few of examples which can be supplied
UNDER WATER VIDEO CAMERA CABLES
SEWER INSPECTION CABLES
MOBILE PHONE SYSTEM CABLES
DENTAL CABLES
METAL DETECTOR CABLES
Please contact Noremak Industries for your cable requirements for Power and Data applications. Noremak can have cables produced toyour requirements in surprisingly short runs and in surprisingly quickturn around times. We can also have leads and special applicationplugs manufacturing capabilities.
Noremak Industries Pty Ltd12 Princess Street
Beverley SA 5009Phone 08 8244 7288 Fax 08 8244 7299