Freimaßtoleranzen DIN 7168 fein mittel grob Oberfläche DIN 1302 Reihe 5 Urheberschutz nach DIN 34 Jede Vervielfältigung, Nachbau oder Weitergabe an Dritte ist untersagt oder bedarf unserer schriftlichen Genehmigung. Format DIN A0 Datum Name Gez. Gepr. Ing. Viehböck Dateiname: a b c d e f g Index Änderung Datum Name Fläche Gewicht Maßstab Werkstoff Oberfläche 24.06.2016 Liftanlage 16-0244.dft 0,000 kg A B C D E F 8 7 6 5 4 3 2 1 G H 11 10 9 12 I J K L B C D E F G H I J K L 13 14 15 16 8 7 6 5 4 3 2 1 11 10 9 12 13 14 15 16 servelift gmbh A-4161 Ulrichsberg Tel. +43(0)7288/27120 Kreuzlandl 3 Fax.+43(0)7288/27120-20 www.servelift.com [email protected] A A section A-A 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 1400 1100 1580 1515 1550 1600 call station: - key switch - call button call station: - key switch - call button call station: - key switch - call button emergency wheel (demountable) 100 1500 4250 I agree with the execution as shown at the drawing: (free for production) date, signature: ............................................................................ Electrical requirements for installation site: Mandatory requirements for installation site according to VdTÜV leaflet Elevators 103 or EN 81-41:2004: - Socket outlet 230V /50Hz protected minimum. B13 for maintenance work near to the lowest station. - Error current - sensitive to universal current– protection (FI) with minimum >= 30mA release current. - Main switch with 2 poles, minimum 25A to disconnect all poles of the main power supply (supply line). This switch must be lockable and is exclusively installed fort he power supply of the elevator. The power supply for lighting and socket outlet must remain life for maintenance work. - Overvoltage protection device type „C“ to protect against external overvoltage from the supply line. (to be installed in the house terminal resp. the nearest sub-terminal. - Grounding for potential equalisation minimum 4mm². - Maximum grounding resistance: 3 ohm - Lightning protection is necessary for outdoor installation of the elevator.. - empty tube minimum 80 mm diameter from electrical cabinet to lift guide - Only for installations with isolated neutral point ( IT-nets): Cut-off transformer minimum approx. 4000VA. Additional requirments: - For externally mounted calling stations : empty tube minimum 25 mm diameter (from electrical cabinet to first door, from 1 st door to 2 nd door, … and so on … - No grounding necessary. (low voltage). - For optional emergency telephone a connection cable with min. 4x0,25 mm² is necessary to the position of the electrical switch box! Electrical characteristics: Nominal voltage: 230V / 50Hz Nominal current: 8,5 A Max. current consumption: 16,4 A shortterm Nominal power (Frequency Converter): 2,2 kW Cross section: Min. 3x2,5 mm² Pre-fuse: Min. C25 Control voltage: 24Vdc – short curcuit proof servelift V10: outdoor - platformsize 1100x1400 mm - max. load capacity 385 kg - smooth start and stop - 3 stops, 3 call stations (key switch "standard", call button => no key switch on lift panel) - lower station: - manual revolving door DIN L - inner door width approx. 995x2074 mm - selfclosing - middle station: - manual revolving door DIN L - inner door width approx. 973,5x2074 mm - selfclosing - upper station: - manual revolving door DIN R - inner dooir width approx. 995x2074 mm - selfdialing emergency telephone "AMIGO II" - battery back-up for emergency lowering in case of power failure - full glass roof - electrical switch box RAL 7035 with heating - thermostate regulated shaft ventilation - all visible surfaces powdercoated RAL 7024 by Hissipörssi OY: - transport - installation - costs for final inspection max. foundation load in the area of the lift guide (230x706mm) approx. 10,6kN under suspension of a force of impact of 5 (fully loaded into safety catch) approx. 53 kN max. foundation load caused by shaft weight approx. 13 kN max. tensile loadings approx. 3,5-4,5 kN at each fixing point! 120 5730 1394 4121 updated according to e-mail from 27th of June 2016 30.6.2016 KV 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 3000 1460 updated according to e-mail from 21st of July 2016 2.8.2016 KV 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass 10 mm laminated glass updated according to e-mail from 3rd of August 2016 3.8.2016 KV 2228 16 full glass roof