Top Banner
PLAN NO. DESCRIPTION 400 SEWER LATERAL CONNECTIONS TYPES A AND B 401-1 TYPICAL SEWER LATERAL HOUSE CONNECTIONS 401-2 TYPICAL SEWER LATERAL NOTES 402-1 PRECAST CONCRETE SEWER MANHOLE 402-2 PRECAST CONCRETE SEWER MANHOLE NOTES 403 STANDARD SEWER DROP MANHOLE WITH CLEAN OUT 404 SEWER DROP MANHOLE WITH CLEAN OUT 405 MANHOLE FRAME AND COVER 406 V.C.P. PIPE BEDDING DETAILS 407 P.V.C. PIPE BEDDING DETAILS 408-1 CLEAN OUT STRUCTURE 408-2 CLEAN OUT STRUCTURE NOTES 409-1 SEWER CHIMNEYS 409-2 SEWER CHIMNEYS NOTES 410 STEEL CASING PIPE 411 CONCRETE ENCASEMENT TYPE A,B AND C 412 GAS FLAP 413 TAPPING SLEEVE FOR PVC/HDPE PIPE LINER 414-1 TRENCHLESS PIPELINE DESIGN CRITERIA 414-2 TRENCHLESS PIPELINE DESIGN CRITERIA NOTES SECTION 400 SEWER AND SANITATION
21

SECTION 400 SEWER AND SANITATION

Mar 24, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: SECTION 400 SEWER AND SANITATION

PLAN NO. DESCRIPTION

400 SEWER LATERAL CONNECTIONS TYPES A AND B

401-1 TYPICAL SEWER LATERAL HOUSE CONNECTIONS

401-2 TYPICAL SEWER LATERAL NOTES

402-1 PRECAST CONCRETE SEWER MANHOLE

402-2 PRECAST CONCRETE SEWER MANHOLE NOTES

403 STANDARD SEWER DROP MANHOLE WITH CLEAN OUT

404 SEWER DROP MANHOLE WITH CLEAN OUT

405 MANHOLE FRAME AND COVER

406 V.C.P. PIPE BEDDING DETAILS

407 P.V.C. PIPE BEDDING DETAILS

408-1 CLEAN OUT STRUCTURE

408-2 CLEAN OUT STRUCTURE NOTES

409-1 SEWER CHIMNEYS

409-2 SEWER CHIMNEYS NOTES

410 STEEL CASING PIPE

411 CONCRETE ENCASEMENT TYPE A,B AND C

412 GAS FLAP

413 TAPPING SLEEVE FOR PVC/HDPE PIPE LINER

414-1 TRENCHLESS PIPELINE DESIGN CRITERIA

414-2 TRENCHLESS PIPELINE DESIGN CRITERIA NOTES

SECTION 400

SEWER AND SANITATION

Page 2: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

SEWER LATERAL CONNECTIONSTYPES A AND B 400

1 OF 104/01/15

Page 3: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

TYPICAL SEWER LATERALHOUSE CONNECTIONS 401-1

1 OF 204/01/15

Page 4: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

TYPICAL SEWER LATERAL NOTES 401-2

2 OF 204/01/15

Page 5: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

PRECAST CONCRETE SEWER MANHOLE 402-1

1 OF 204/01/15

Page 6: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

PRECAST CONCRETE SEWER MANHOLE NOTES 402-2

2 OF 204/01/15

Page 7: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

STANDARD SEWER DROPMANHOLE WITH CLEAN OUT 403

1 OF 104/01/15

Page 8: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

SEWER DROP MANHOLE WITH CLEAN OUT 404

1 OF 104/01/15

Page 9: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

SEWER MANHOLE FRAME AND COVER 405

1 OF 104/01/15

Page 10: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

V.C.P. PIPE BEDDING DETAILS 406

1 OF 104/01/15

Page 11: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

P.V.C. PIPE BEDDING DETAILS 407

1 OF 104/01/15

Page 12: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

CLEAN OUT STRUCTURE 408-1

1 OF 204/01/15

Page 13: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

CLEAN OUT STRUCTURENOTES 408-2

2 OF 204/01/15

Page 14: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

SEWER CHIMNEYS 409-1

1 OF 204/01/15

Page 15: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

SEWER CHIMNEYSNOTES 409-2

2 OF 204/01/15

Page 16: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

STEEL CASING PIPE 410

1 OF 104/01/15

Page 17: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

CONCRETE ENCASEMENTTYPE A,B, AND C 411

1 OF 104/01/15

Page 18: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

GAS FLAP 412

1 OF 104/01/15

Page 19: SECTION 400 SEWER AND SANITATION

04/01/15

413

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

1 OF 1

TAPPING SLEEVE FOR PVC / HDPE PIPE LINER

Page 20: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

TRENCHLESS PIPELINE DESIGN CRITERIA 414-1

1 OF 204/01/15

Page 21: SECTION 400 SEWER AND SANITATION

CITY OF FOUNTAIN VALLEYREVISIONS

MARK LEWIS R.C.E. 49335CITY ENGINEER

APPROVED BY:DATE:

SHEET:

STANDARDPLAN NO.

TRENCHLESS PIPELINE DESIGN CRITERIANOTES 414-2

2 OF 204/01/15