GB Table of Contents Page General Section ....................................... 2 … 3 Operating Hints .............................................................................. 2 Adjustment Procedures .......................... 6 … 9 Set of parameters .......................................................................... 9 Circuit Diagrams and Layout of PCBs ............................ 10 … 41 Circuit Diagrams RF Part ..................................................................................... 10 Processor Part .......................................................................... 14 Sound Control ........................................................................... 17 Cassette Part ............................................................................ 20 Operating Board ....................................................................... 22 Diagnoses and ext. Display ...................................................... 24 Sound Control Headphone ....................................................... 28 Amplifier Part ............................................................................ 30 Connection Board ..................................................................... 33 Layout of PCBs ............................................................................ 35 Spare Parts Lists and Exploded Views ................................... 42 … 46 Exploded View and Spare Parts List Tape Drive ......................... 42 Spare Parts List AURA ................................................................ 44 D Inhaltsverzeichnis Seite Allgemeiner Teil ...................................... 2 … 3 Bedienhinweise .............................................................................. 2 Abgleichvorschriften .............................. 4 … 9 Parametertabelle ............................................................................ 9 Schaltpläne und Druckplattenabbildungen ................... 10 … 41 Schaltpläne HF-Teil ...................................................................................... 10 Prozessor-Teil ........................................................................... 14 Klangsteller ............................................................................... 17 Kassetten-Teil ........................................................................... 20 Bedienplatte .............................................................................. 22 Diagnose und ext. Display ........................................................ 24 Klangsteller Kopfhörer .............................................................. 28 Endstufen-Teil ........................................................................... 30 Anschlußplatte .......................................................................... 33 Druckplattenabbildungen ............................................................. 35 Ersatzteillisten und Explosionszeichnungen ..................... 42 … 46 Explosionszeichnung und Ersatzteilliste Laufwerk ...................... 42 Ersatzteilliste AURA ..................................................................... 44 Zusätzlich erforderliche Unterlagen für den Komplettservice Additionally required Documents for the Complete Service Service Manual Service Manual AURA Dieses Service Manual ist nur in Datenform verfügbar This Service Manual is only available as data Änderungen vorbehalten Subject to alteration Made by GRUNDIG in Germany VK233 0399 72010 792 9000 Sicherheit Safety Mat.-Nr./Part No. 72010 800 0000 Service-Management
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
GB Table of Contents
Page
General Section ....................................... 2 … 3Operating Hints .............................................................................. 2
Adjustment Procedures.......................... 6 … 9Set of parameters .......................................................................... 9
Circuit Diagramsand Layout of PCBs ............................ 10 … 41Circuit Diagrams
RF Part ..................................................................................... 10Processor Part .......................................................................... 14Sound Control ........................................................................... 17Cassette Part ............................................................................ 20Operating Board ....................................................................... 22Diagnoses and ext. Display ...................................................... 24Sound Control Headphone ....................................................... 28Amplifier Part ............................................................................ 30Connection Board ..................................................................... 33
Layout of PCBs ............................................................................ 35
Spare Parts Lists andExploded Views ................................... 42 … 46Exploded View and Spare Parts List Tape Drive ......................... 42Spare Parts List AURA ................................................................ 44
D Inhaltsverzeichnis
Seite
Allgemeiner Teil ...................................... 2 … 3Bedienhinweise .............................................................................. 2
Aufruf des ´extended Expert Modus´:Gerät ausschalten. Stationstaste 2 drücken, gedrückt halten und Gerät einschalten. Stationstaste 2 länger als 10 Sekunden gedrückt halten.TAPE/CD-Taste drücken und ca. 5 Sekunden gedrückt halten bis im Display die Anzeige SE-XX-MC (XX = Softwareversion) erscheint.Taste TP/ASdrücken und ca 5 Sekunden gedrückt halten bis zum zweiten Signalton. Mit den Tasten < bzw. > den entsprechenden Parametersatz anwählen(Anzeige z.B. 00 1400). Taste TP/AS kurz drücken (zusätzliches E im Display: E 00 1400). Mit den Tasten < bzw. > den Wert ändern. Taste TP/ASkurz drücken (E erlischt wieder).
Sollte versehentlich ein anderer Parameter geändert werden, können Sie dessen korrekten Wert aus der Parametertabelle auf der S eite9 entnehmen.
Beenden des ´extended Expert Modus´:Gerät ausschalten.
Abgleich Vorbereitung Abgleichvorgang
MW;DC-Voltmeter an FMP705.
LW;DC-Voltmeter an FMP705.
Meßsender an Antenneneingang; Frequenz 1548kHz; ohneModulation; E´ = 100µV (40dBµV).DC-Voltmeter an FMP602.
Meßsender an Antenneneingang; ohne Modulation;E´ = 100µV (40dBµV).DC-Voltmeter an FMP602.
Meßsender an Antenneneingang; ohne Modulation;E´ = 100µV (40dBµV).DC-Voltmeter an FMP602.
Meßsender an Antenneneingang; Frequenz 1008kHz; ohneModulation.Extended Expert Modus aktivieren (s. o.).Signal mit E´ = 250µV (48dBµV) anlegen. DX deaktivieren.
Signal mit E´ = 20µV (26dBµV) anlegen. DX aktivieren.
FM;DC-Voltmeter an FMP705.
Meßsender an Antenneneingang; Frequenz 95,0MHz; ohneModulation; E´ = 100µV (40dBµV).DC-Voltmeter zwischen FMP101 (+) und FMP103 (-).
Meßsender an Antenneneingang; Frequenz 98,0MHz;fmod = 1kHz; Hub = 22,5kHz;E´ = 1mV (60dBµV).NF-Voltmeter an FMP101.Extended Expert Modus aktivieren (s. o.).Parametersatz 48 anwählen.
Wobbler an Antenneneingang; Mittenfrequenz 95,0MHz;∆f = ± 100kHz; ohne Modulation; E´ = 100µV (40dBµV).Oszilloskop an FMP104.
Meßsender an Antenneneingang; Frequenz 95,0MHz; ohneModulation; E´ = 70µV (37dBµV).DC-Voltmeter zwischen FMP101 (+) und FMP103 (-).
Mit L606A bei 531kHz auf 1,0V ± 50mV abgleichen.Kontrolle auf 7,0V ± 0,5V bei 1602kHz.
Mit L607AL bei 153kHz auf 1,3V ± 50mV abgleichen.Kontrolle auf 5,0V ± 0,5V bei 279kHz.
Mit L604A auf maximale Spannung abgleichen.
Wechselweise mit C608A bei 1548kHz und mit L601A bei558kHz auf maximale Spannung abgleichen.
Mit L602AL bei 162kHz auf maximale Spannung abglei-chen.
Parameterwert 01 solange ändern bis Suchlauf geradestoppt.
Parameterwert 00 solange ändern bis Suchlauf geradestoppt.
Mit L06 bei 87,5MHz auf 1,6V ± 50mV abgleichen.Kontrolle auf 6,5V ± 0,5V bei 108MHz.
Wechselweise mit L03 und L04 auf Maximum abgleichen.
Mit L05 auf Maximum abgleichen.
Durch Ändern des Wertes auf minimale Anzeige (≤ 10mV)am NF-Voltmeter einstellen.
Mit L 101 auf symmetrischen Spannungssprung einstellen.95,0MHz
+5V
0V∆f≤ ± 45kHz
Mit CR26 auf +300mV ± 10mV einstellen.
1. MW-Oszillator
2. LW-Oszillator
3. AM-ZF
4. MW-Vorkreis
5. LW-Vorkreis
6. AM-Suchlaufstop
7. FM-Oszillator
8. FM-HF- und ZF-Kreise
9. ZF-Mittenfrequenz
10. Stop-Generator
11. Feldstärke
AURA Abgleichvorschriften / Adjustment Procedures
GRUNDIG Service 5
Abgleich Vorbereitung Abgleichvorgang
2. CassettenlaufwerkMeßgeräte: Frequenzzähler, Test-Cassette 448A (Material Nr. 35079 023 0000)
Bandgeschwindigkeit
Abgleich Vorbereitung Abgleichvorgang
Test-Cassette 448A einlegen und 3150Hz-Teil abspielen.Frequenzzähler an Lautsprecher-Ausgang .
Mit Motorpoti auf 3150Hz ± 100Hz einstellen.
Motorpoti
Zum Abgleich die Antennennachbildungen für AM bzw. FM verwenden
EMK
Rg
50Ω
Kabel50Ω 37.5Ω 55Ω
15pF
150Ω
37.5
Ω
60pF
E´
E´= EMK - 26dBAM
EMK
Rg
50Ω
Kabel50Ω 10Ω 45Ω
10nF
60Ω
75Ω
E´
E´= EMK - 6dBFM
Durch Ändern des Wertes auf minimale Anzeige am NF-Voltmeter im rechten Kanal einstellen.
Parameterwert 03 solange ändern bis Suchlauf geradestoppt.
Parameterwert 02 solange ändern bis Suchlauf geradestoppt.
Parameter 65 auf errechneten Wert ändern.Z.B.: E 65 44
Meßsender mit Stereo-Coder an Antenneneingang; Fre-quenz 94,8MHz; fmod 1kHz mit 22,5kHz Hub; Pilotton 19kHzmit 7,5kHz Hub; RDS 57kHz mit 1,2kHz Hub; E´ = 1mV(60dBµV). Nur linken Kanal modulieren.NF-Voltmeter an Lautsprecher-Ausgänge .Extended Expert Modus aktivieren (s. o.).Parametersatz 53 anwählen.
Meßsender an Antenneneingang; Frequenz 95,0MHz; ohneModulation.Extended Expert Modus aktivieren (s. o.).Signal mit E´ = 80µV (38dBµV) anlegen. DX deaktivieren.
Signal mit E´ = 8µV (18dBµV) anlegen. DX aktivieren.
Dolby Rauschunterdrückung ist hergestellt unter Lizenz von Dolby Laboratories Licensing Corporation.DOLBY und das Doppel-D-Symbol g sind Warenzeichen der Dolby Laboratories Licensing Corporation.NR = Noise Reduction (Rauschunterdrückung).
12. Stereo-Überspre-chen
13. FM-Suchlaufstop
14. Übertemperatur-abschaltung
AURA Abgleichvorschriften / Adjustment Procedures
GRUNDIG Service 7
GB Adjustment Procedures
1. Main BoardTest equipment: DC Voltmeter, Test Generator, AF Voltmeter, Stereo Coder, Sweep Generator, Oscilloscope
Calling up the ´extended Expert Mode´:Switch off the set. Press and hold depressed station button 2 and switch on the set. Hold the station button 2 depressed for more than 10 seconds.Press and hold depressed the TAPE/CD button for about 5 seconds until the display shows SE-XX-MC (XX = Version of software). Press button TP/ASfor more than 5 seconds until after the second sound. With the buttons < resp. > select the corresponding parameter set (display shows e.g. 00 1400).Press button TP/AS briefly (additional E in the display: E 00 1400). With the buttons < resp. > change the value. Press button TP/AS briefly (E goesout).
If you changed an other parameter by mistake you can find its correct value in the parameter table on page 9.
Leaving the ´extended Expert Mode´:Switch off the set.
1. MW Oscillator
2. LW Oscillator
3. AM IF
4. MW Bandpass
5. LW Bandpass
6. AM search levelstop
7. FM Oscillator
8. FM RF and IF
9. IF Center fre-quency
10. Stop Generator
11. Field strength
Adjustment Preparation Adjustment Procedure
MW;Connect a DC Voltmeter to FMP705.
LW;Connect a DC Voltmeter to FMP705.
Connect a Test Generator to aerial input; Frequency1548kHz; no modulation; E´ = 100µV (40dBµV).Connect a DC Voltmeter to FMP602.
Connect a Test Generator to aerial input; no modulation;E´ = 100µV (40dBµV).Connect a DC Voltmeter to FMP602.
Connect a Test Generator to aerial input; no modulation;E´ = 100µV (40dBµV).Connect a DC Voltmeter to FMP602.
Connect a Test Generator to aerial input; Frequency1008kHz; no modulation;Call up the extended expert mode (see above).Apply a signal with E´ = 250µV (48dBµV). Set DX to OFF.
Apply a signal with E´ = 20µV (26dBµV). Set DX to ON.
FM;Connect a DC Voltmeter to FMP705.
Connect a Test Generator to aerial input; Frequency95.0MHz; no modulation; E´ = 100µV (40dBµV).Connect a DC Voltmeter between FMP101 (+) andFMP103 (-).
Connect a Test Generator to aerial input; Frequency98.0MHz; fmod = 1kHz; Hub = 22.5kHz; E´ = 1mV (60dBµV).Connect an AF Voltmeter to FMP101.Call up the extended expert mode (see above).Select parameter 48.
Connect a sweep generator to aerial input. Center fre-quency 95.0MHz ; ∆f = ± 100kHz; no modulation;E´ = 100µV (40dBµV);Connect an Oscilloscope to FMP104.
Connect a Test Generator to aerial input; Frequency95.0MHz; no modulation; E´ = 70µV (37dBµV).Connect a DC Voltmeter between FMP101 (+) andFMP103 (-).
Align with L606A at 531kHz for 1.0V ± 50mV.Check for 7.0V ± 0.5V at 1602kHz.
Align with L607AL at 153kHz for 1.3V ± 50mV.Check for 5.0V ± 0.5V at 279kHz.
Align with L604A for maximum voltage .
Align alternating with C608A at 1548kHz and with L601A at558kHz for maximum voltage .
Align with L602AL at 162kHz for maximum voltage .
Change Parameter value 01 until search just stops.
Change Parameter value 00 until search just stops.
Align with L06 at 87.5MHz for 1.6V ± 50mV.Check for 6.5V ± 0.5V at 108MHz.
Align alternating with L03 and L04 for maximum .
Align with L05 for maximum .
Set the parameter value for minimum AF voltage .
Align L 101 for a symmetrical stop impulse.95.0MHz
+5V
0V∆f≤ ± 45kHz
Adjust with CR26 for +300mV ± 10mV.
Abgleichvorschriften / Adjustment Procedures AURA
8 GRUNDIG Service
Adjustment Preparation Adjustment Procedure
2. Tape DriveTest equipment: Frequency counter, Test Cassette 448A (Part No. 35079 023 0000)
Tape Speed
Adjustment Preparation Adjustment Procedure
Insert Test Cassette 448A and play 3150Hz part.Connect a frequency counter to loudspeaker outputs .
With the ´Motorpoti´ adjust for 3150Hz ± 100Hz.
Motorpoti
EMK
Rg
50Ω
Kabel50Ω 37.5Ω 55Ω
15pF
150Ω
37.5
Ω
60pF
E´
E´= EMK - 26dBAM
For adjustment use the aerial dummies for AM resp. FM
EMK
Rg
50Ω
Kabel50Ω 10Ω 45Ω
10nF
60Ω
75Ω
E´
E´= EMK - 6dBFM
12. Stereo Crosstalk
13. FM search levelstop
14. Power AmplifierOver Temperature
Connect a Test Generator via a Stereo Coder to aerialinput; Frequency 95.0MHz; fmod 1kHz at 22.5kHz dev.; Pilot19kHz at 7.5kHz dev.; RDS 57kHz at 1.2kHz dev.; E´ = 1mV(60dBµV); modulate only the left channel .Connect an AF Voltmeter to loudspeaker outputs .Call up the extended expert mode (see above).Select parameter 53.
Connect a Test Generator to aerial input; Frequency95.1MHz; no modulation;Call up the extended expert mode (see above).Apply a signal with E´ = 80µV (38dBµV). Set DX to OFF.
Apply a signal with E´ = 8µV (18dBµV). Set DX to ON.
In ´cold´ condition measure the voltage Um at FMP1609.Calculate the parameter value: W = (Um - 340mV) / 16.9mV.e.g.: Um = 1.20V. W = (1200mV - 340mV) / 16.9mV.W = 860mV / 16.9mV = 43.8 = 44.
Set the parameter value for minimum AF voltage on theright channel .
Change Parameter value 03 until search just stops.
Change Parameter value 02 until search just stops.
Change Parameter 65 to the calculated value.e.g.: E 65 44.
Dolby noise reduction under license from Dolby Laboratories Licensing Corporation.„DOLBY“ and the double D Symbol g are trademarks of Dolby Laboratories Licensing Corporation.NR = Noise Reduction.
AURA Abgleichvorschriften / Adjustment Procedures
GRUNDIG Service 9
Parametertabelle / Set of Parameters
0 AM level DX
1 AM level LOCAL2 FM level DX
3 FM level LOCAL
4 38405 2920
6 2580
7 18008 2600
9 380
10 48011 3360
12 2980
13 260014 2200
15 2200
16 258017 3
18 10
19 2520 60
21 60
22 223 10
24 255
25 25526 20
27 5028 80
29 2
30 7531 180
32 0
33 134 2
35 15
36 5
37 8038 248
39 21
40 23141 239
42 133
43 11244 34
45 126
46 13347 98
48 ZF-Mitteneinstellung / IF center
49 650 4
51 3
52 753 Übersprechen / Stereo Crosstalk
54 46
55 056 170
57 18
58 1559 3
60 1
61 962 8
63 764 0
65 Endstufentemperatur / Amplifier Temp.
66 254
Parameter Wert BeschreibungValue Description
Parameter Wert BeschreibungValue Description
Schaltpläne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBs AURA
10 GRUNDIG Service
Schaltpläne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBs
HF-Teil / RF Part
3
2
1
8602
-223
-080
F02
31
F03V
80527P
CC01
FMP02
603
CR
2407
P
10K
1206
CR2411P
4R7
603
CR
11
470R
BC858C
CT2409P
603
CR
16
56K
603
CR
13
10K
603
CR
14
47K
603
CC
2401
P
100N
BC848C
CT2406P
FMP01
603
CR
12
47K
603
CR01
22R603
CR08
10K603
CR09
47K
603
CR33
330K
603
CR
06
330K
603
CR2416P
1K0
47K BCR135
10K CT2407P
603
CR
2403
P
10K60
3
CR
2404
P
10K
603
CR
2409
P
10K
603
CC
2403
P
10N
805
CC
07V
1N0
NP
0
1206
CR2412P
4R7
BC848C
CT2411P
603
CR
2406
P
6K8
8053P3
CC02V
603
CC
42
FMP04
6034P7
CC16
805
NP0
1N0
CC18
60312P
CC19
805
NP0
1N0
CC24
6036P8
CC23
805NP0 1N0
CC22
805
NP
01N
0
CC
04
805
NP
01N
0
CC
08
805
NP
01N
0
CC
12
603
100N
CC
43
805
NP0
1N0
CC17
603
CR
2413
P
33K
FMP03
1
3
4
6
7 8
8140
-533
-904
L03
8325
-325
-805
BB
804
CD
03BFR93AR
CT01
BC858C
CT2408P
BC368
T2401P
AN1
BC858C
CT2404P
BC848C
CT2412P
8140
-516
-057
2U2
CL0
1
603
CR
03FQ
0R
BC858C
CT02
8325
-795
-392
BA
779S
CD
028325-325-805
BB804
CD04
8140
-516
-057
2U2
CL0
2
41
3
2
L04
8140-530-270
805
CR
34
220R
U4065B
& IFWIDE BAND
FERENCEINTER-
MIXER
DETECTOIF &
MIXER
AGC
1716151413
12 11 10 9 8
8305-154-065
CIC01
+
10U
/16V
C24
02P
603 10
0N
CC
2404
P
603
CR
2408
P
33K
603
CR
2415
P
47KFMP2401
603
CR
2420
P
47K
603
CR
2414
P
10K
603
CR
2405
P
3K9
603
CR
07V
10R
0R
R2401P
0R
R2402P
805
CC13
27P
+A ANT-ONPHANTOM
AM
-AN
T
FM/A
M-A
BS
T
+S
ABGLEICHPUNKTE
MESSPUNKTE
ANT
240104
0302
01
M
H
SPA
108 MHz -> ca.6.5V
87.5MHz -> 1.6V
MISCHTEILMIXER SECTION
*
*
*
*
*
*
*
*
*
*
*
*
*
*
* *
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
* *
*
*
*
**
*
+9.2V
+14V
AURA Schaltpläne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBs
GRUNDIG Service 11
3
2
1
8602-222-190
F102
3
2
1F0
1V
8602
-223
-080
3
2
1F0
3V
CC
616A
603
47N
CC
606A
5P5-
30P
C60
8A
BC848C
BC818/40
CT602AL
603
100N
CC
607A
CR26
4K7
8775
-009
-089
805
CR
122
10R
+
10U
/16V
C11
7
603
CR112V
120R
BA
V99
CD
601F
Z
603
CR109V
0R
805
CR
27
4R7
603
56K
603
CR
21
10K
603
CR
18
15R
100N
603
CR22
470R
603
CR23
820R60
3
CR
28
4K3
603
CR
31
330R
+
10U
/16V
C60
4A
603
6N8
CC
116
60322N
CC41
603
CR32
22R
603
22N
CC
118
60322N
CC103
60322N
CC104
805
NP
01N
0
CC
37
603
100N
CC
42
60322N
CC29
805
NP
01N
0
CC
31
805
NP0
1N0
CC24
805
NP
01N
0
CC
39
603
6P8
CC
33
603100N
CC27
603
CC26
4P7603
22P
CC34
60347P
CC36
603
100N
603
CR
29FL
0R
603
CR101FN
0R
603
CR
111V
180R
603
CR
24
1K2
1000UH
L2401V
603
CR19
470R
CD
05
8325
-325
-805
BB
804
UREFUST
DETEKTORPEGEL-
VERSTAERKERZF-
181920
1 2
603180P
CC28
4 1 3
2 L06
8140
-530
-269
BA
S16
CD06V
603
100N
CC
612A
603
CR
602A
820K
603
CR
616A
L
1K8
603
CR
604A
560K
603
CR
603A
1M0
603
CR
614A
22K
603
CR
608A
270R
603
CR
607A
1M0
603
CR
612A
2K7
603
CR606A
100R
805
1N0
CC
602A
603
330R
CR
613V
7 81
3 4
68140
-533
-118
L602AL
7 81
3 4
68140
-533
-165
L601A
603
NP
012
P
CC
611A
L
8309
-428
-511
G1
G2 S
D
BF992A
CT601A
MIXER
IF2
IF1
DETECTORIF &
REG.VOLTAGE
OSCI
LOCAL
242322212019181716
9 8 7 6 5 4 3 2 1
+
10U
/16V
C24
02P
8051N0
CC603A
603
CR
2417
P
100K
Z47
CD
2401
P
87 6
43
2
1 8141
-154
-350
L05
FMP06
FMP05
FMP601
+
22U
/16V
C38
AM
-AN
T
AM
-AN
T
+FM
FELD
ST
FM-O
SZ
+S
LW 153 KHZ - 279 KHZMW 531 KHZ - 1602 KHZ
WELLENBEREICHE:WAVE BANDS
6010605
FM-ZFFM IF
M
H
M
H
AM SECTION
AM-TEIL
LW
MW
VOLTAGE SUPPLY FOR ACTIVE AERIAL (DC)
SPANNUNGSVERSORGUNG FUER AKTIVANTENNE
ca. 12V0
500mV
*
*
*
** *
*
*
*
*
*
*
*
*
*
*
* *
*
*
*
*
+9.2V
+9.2V
Schaltpläne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBs AURA
12 GRUNDIG Service
603
NP
012
0P
CC
649V
603
22N
CC637A
603
100N
CC
626A 60
322
N
CC
627A
L
603
2N7
CC
623A 60
34N
7
CC
624A
603
100N
CC
616A
603
100N
CC
621A
8051N0
CC617A
BC818/40CT607AL
BC848C
CT604A
BC848C
CT603A
L
1
3
78
8140
-535
-116
L606
A
1
3
78
8140
-535
-106
L607
AL
603
15N
CC
633V
603
CR117
33K
+
10U
/16V
C11
7
OSCIN
HFRE
AM_IN
IF_FM
IF_AM
SDA
SCL
ADDR
OSCOUT
FM_IN
I
9
10
12
13
14
15
19
20
24
25
B101
603 10
0N
CC
107
603
CR
119
8K2
603
CR
118
1K8
603
6N8
CC
116
603
100N
CC
119V
603
CR
701V
10K
603 10
0P
CC
109
603
CR
702V
10K
603 10
0N
CC
112
603 10
0N
CC
113
603
22N
CC
114
603
22N
60322N
CC103
603
CC701
22N
8382
-212
-102
10M
Hz2
5
Q70
1
603
CC
704
10N
603
CR114
47K
BC848C
CT103
1
3
78
L101
8140-535-256
603
CR113
10K
CT104
BC848C
60310N
CC106
603 10
0N
CC
108
805
CC
635V
220N
1593T
1MHZ
50khz
DEMOD.QUADRATUR
KOMP.KLIRRFAKT-
DETEKTORVERSTIMM-FM-AUS
SCHALTUNGSTUMM-
STOP-LOGIKABSTIMM-
TDA
UREF
9 10
11121314151617189
2 3 4 5 6 7 8
CIC101
8305-841-593
603
CR
116
1K8
603
CR
123F
L
18K
603
CR645AH
5K6
603
100N
CC
646A60
322
N
CC
639A
603
22N
CC
632V
805
NP0 180P
CC641V
603
CR
636A
47K
603
47N
CC
631A
603100N
CC618A
60310N
CC613A
603100N
CC638A
603100N
CC652A
BC848C
CT609AL
603
CR
646A
22R
603
CR649AL
47K
603
CR
647A
0R
603
CR
631A
47R
603
CR
616A
L
1K8
603
CR
644A
L
22K
603
CR
639A
47K
603
CR
643A
L
22K
603
22P
CC
648A
603
CR628A
10R
603
CR
629A
150R
603
CR
622A
2K7
603
CR624A
47K
603
CR
632A
10R
603
CR621A
680K
603
CR
618A
100K
603
CR
619A
180R
603
CR633A
3K3
603
CR
641A
L
10K
603
CR
637A
1K8
603
CR
648A
2K2
603
CR
634A
22R
603
CR
642A
L
2K2
603
CR
653V
10K
+
10U/16V
C644AL
B102
5UH6
CL603A
G
S
D
BF543
CT606A
7K
n. c
.
50R
220R
170R
12K7KVR
V1 V2 V3
V1
+
V3
V2 VR(AGC) 3K
525
R
VR(AGC)
3K
RF STAGECONTROLLED
GAIN-
MIXERBALANCED
DOUBLE STANDBYTROLLED IFGAIN CON-
VOLTAGESSUPPLY
INTERNAL
BALANCEDFULL-WAVE
DRIVER
SWITCHAMPLIFIER DETECTOR
OSCILLATOR
CONTROLLED
AMPLIFIERAF PRE-
INDIKATOR
AMPLIFIERAGC
AMPLIFIERIF
TDA1572T
n. c
.
10987654321
20 19 18 17 16 15 14 13 12 11
8305-841-572
CIC601A
BC818/40
CT608AL
805
NP
033
P
CC
642A
L
7 81
3 4
6
8140-533-131
L604A
8309
-428
-511
BB
512
CD
602A
8309-428-511
BB512
CD603A
603
CR
626A
1M0
603
CR
623A
22R
603
CR627A
10R
805
NP
027
0P
CC
643A
L
603
100N
CC
614A
8051N0
CC622A
8051N0
CC628A
1206
CC
629A
2N2
NP
0
805
68N
CC
111
603
CR
638V
4K7
A2
A1
GNDE
4
3
2
1
8602-810-055
F601AH
FMP101
FMP102
FMP103 FMP104 FMP701
+
47U
/10V
C61
9A
+
1U/5
0V
C63
4A
+
10U
/16V
C63
6A
AM
-ZF
+AM
MP
X(R
DS
)MU
TE
SD
A
SC
L
FELD
ST
FM/A
M-A
BS
TM
PX
UR
EF
FM-O
SZ
K-S
IGN
AL
AM
-OS
Z
FM-S
TOP
AM
-NF
V3
GR
I
GRI
LW 1,3V - ca. 5V
MW 1,0V - ca. 7V
701104103102101
M-ZFM IF
LW
MW
*
*
*
*
*
*
*
*
*
*
*
**
*
*
*
* *
*
*
*
*
*
*
*
*
*
**
*
*
*
*
*
** *
*
*
*
*
*
*
*
*
*
*
+9.2V
AURA Schaltpläne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBs
GRUNDIG Service 13
603
4N7
CC
654A
OSCIN
LPAM
LPFM
LPHC
INLO
CK
NC
HFREF
AM_IN
PUMPCOMP
NC
+
-
GNDDIG
VDD1
VDD2
VDD1
GNDAN
VREF
LPOUT
INLOCK
DO
UT6
DO
UT5
DO
UT4
DO
UT3
DO
UT2
DO
UT1
SSTOP
IF_FM
IF_AM
SDA
SCL
ADDR
OSCOUT
FM_ININLOCK
11 - 21 BIT PROG.CNT RESET
POWER ON
PORT EXTENSIONCONTROLTIMER14 BIT PROG.CNT
LOGIC
TEST
INTERFACE
I2C BUS
16 BIT PROG.CNTREF.OSCILLATOR
CHARGEPHASE11 BIT PROG.CNTSWM/DIR SWM/DIR
SWITCH SWITCH
LP1/LP2
SWITCH
DETECTOR5 BIT PROG.CNT
:32/33
PRECOUNTER
AM/FM
SWITCH
1
2
3
4
5 6 7 8
9
0
2
3
4
5
16 17 18
9
0
21
22
23
4
5
26
27
28
11
8305-847-428
TDA7427D
CIC701
805
CC
713
1N0
603
CR
703
47R
603
CR
704
22R
+
100U
/10V
C70
7
805
CR
708
220R
603
CR
707A
100K
603
CR705
8K2
47K
DTA
143Z
K
4K7
CT7
04A
L
603
CC
709
47N
603
6N8
CC
715A
603
CC
712
100N
+
22U
/16V
C70
6
603
CR
706
27K
805
68N
CC
716A60
3
CC
714
10N
47K DTA143ZK
4K7
CT703AL
BC808/40
CT702A
603100N
CC652A
603
22N
CC
653A
L
603
CR649AL
47K
603
CR
651A
L
3K3
603
CR
652A
L
100K
603
CR
648A
2K2
n. c
.n.
c.
10
11
CIC601A
+
10U
/16V
C71
1
603
CR709AL
100K
603
CR
712A
47K
BC808/40
CT701A
603
CR713A
4K760
3
CR
714A
47K603
CR711A
4K7
805
CC
708
NP
01N
0
701
FMP702
FMP703
FMP704
FMP705
FMP706
FMP
602
FMP
603
FMP
604
FMP
605
805
NP
01N
0
CC
705
AM
-STO
P
AM
-ZF
+AM
+G
+MW
+MW
+FM
FELD
ST
FM/A
M-A
BS
T
+S
AM
-OS
Z
+LW
+LW
19373-129.00 SEAT AURA
703 704 706 705702605604603602
MAIN BOARD
HAUPTPLATTE
Loop AMLoop FM
AM-FM PLL
*
*
*
*
*
*
*
* *
*
*
* *
*
*
*
*
*
*
*
*
*
+9.2V
+9.2V+9.2V+9.2V
+9.2V
+9.2V +9.2V
+5V
* = BAUTEILE REFLOWSEITE* = COMPONENTS REFLOW SIDE
Schaltpläne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBs AURA
Btx *32700# ÄNDERUNGEN VORBEHALTEN / SUBJECT TO ALTERATION
( ! )!Es gelten die Vorschriften und Sicherheitshinweise
gemäß dem Service Manual "Sicherheit", Sach-Num-mer 72010 800 0000, sowie zusätzlich die eventuellabweichenden, landesspezifischen Vorschriften!
The regulations and safety instructions shall be validas provided by the "Safety" Service Manual, partnumber 72010 800 0000, as well as the respectivenational deviations.
Ersatzteillisten und Explosionszeichnungen / Spare Parts Lists and Exploded Views AURA
44 GRUNDIG Service
Btx *32700# ÄNDERUNGEN VORBEHALTEN / SUBJECT TO ALTERATION
ErsatzteillisteSpare Parts List
SEAT AURASACH-NR. / PART NO.: 91835 981 5100BESTELL-NR. / ORDER NO.: G.HH 7800
Ersatzteillisten und Explosionszeichnungen / Spare Parts Lists and Exploded Views AURA
Änderungen vorbehalten Made by GRUNDIG in Germany Subject to alterationVK 233 0399 72010 792 9000
Btx *32700# ÄNDERUNGEN VORBEHALTEN / SUBJECT TO ALTERATION
( ! )!Es gelten die Vorschriften und Sicherheitshinweise
gemäß dem Service Manual "Sicherheit", Sach-Num-mer 72010 800 0000, sowie zusätzlich die eventuellabweichenden, landesspezifischen Vorschriften!
The regulations and safety instructions shall be validas provided by the "Safety" Service Manual, partnumber 72010 800 0000, as well as the respectivenational deviations.
POS. NR. SACHNUMMER BEZEICHNUNGPOS. NO. PART NUMBER DESCRIPTION
POS. NR. SACHNUMMER BEZEICHNUNGPOS. NO. PART NUMBER DESCRIPTION