Top Banner
Fauquier County Scott RIT Pak III
30

Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Apr 27, 2018

Download

Documents

votuong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Fauquier County

Scott RIT Pak III

Page 2: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Objectives

Identify the parts of the RIT Pak III system

Identify options for supplying air from the RIT Pak III to a downed fire fighter

Demonstrate how to secure the RIT Pak III to a downed fire fighter

Page 3: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Overview

Dimensions

– 33” L x 10.5” W x 8.5” H

– Weight approximately 38 pounds

Features

– Reflective Stripes

– Skid Plate for easier dragging

– External pressure gauge

– Easy grip handles

– Low air alarm bell

Page 4: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Overview cont.

Parts

– Carrying bag

– Adjustable shoulder strap

– 6’ EBSS Hose

– 5’ UAC Hose

– RIT Pak III face piece

– EZ Flo Regulator

– 60 minute SCBA cylinder

Page 5: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Overview cont.

Maintenance

– Inspect cylinder and bag after every use

– Check all air hoses for damage

– Clean the carrying bag as needed with a mild detergent

– Dry thoroughly, do not store wet

Page 6: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Overview

Compartment with the round handle; Low pressure connections

Compartment with the “T” Handle; High Pressure connections

Page 7: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Overview

Pressure Gauge with LED lights

Two Green Lights = Full

One Orange Light = Half

One Red light = One quarter

Page 8: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Air Connections

RIC Hose aka UAC (Universal Air connection)

– Theory- air pressure will equalize between regardless of cylinder size

If the down fire fighter's cylinder is damaged do not attempt the UAC

– Connection

Must be straight on, if not, damage to pin may occur

Takes approximately 30 seconds to equalize

Note: This is the primary method of providing air to a downed fire fighter

Page 9: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do
Page 10: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Air Connections

UAC cont.

– Techniques

Grasp the UAC on the down firefighter’s pack with your thumb up

Follow your thumb down to the UAC and make the connection

Page 11: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do
Page 12: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Air Connections

UAC

– Operations

Ensure the fire fighter’s pack is operational and is not damaged

Ensure both the RIT bag and Air Pak are turned fully on

Remove the dust cap from both UAC connections

Place the UAC hose on the UAC connection and press firmly

Once the transfer is complete remove the hose and return it to the carrying bag

Page 13: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Air connections

Low Pressure Hoses

– Male and Female connections

Buddy Breather

Regulator

– Techniques

Connect the fire fighter’s buddy breather to the low pressure hose from the RIT bag (male or female is acceptable)

Connect the low pressure hose to the fire fighter’s face piece

Page 14: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do
Page 15: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Air Connections

Low Pressure Hose cont.

– Operation

If the fire fighter’s cylinder is damaged do not attempt the UAC

Connect the RIT buddy breather to the fire fighter’s buddy breather

Connect the low pressure hose to the regulator

– NOTE: when the RIT buddy breather is attached to a non-RIT regulator the vibralert will constantly vibrate

Page 16: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do
Page 17: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Air Connections

Face piece and Regulator Change Out – Parts

Scott Sure Fit RIT III Face Piece with metal pull rings

EZ Flo Regulator without alarm

– Replacement of Regulator Turn on air at RIT regulator (purge valve or depress

center)

Remove fire fighter’s regulator

Place RIT regulator on fire fighter’s face piece and turn until locked

– NOTE: there is no vibralert in the RIT regulator, instead there is a bell in the pressure reducer that dings when the air supply is at ¼ full

Page 18: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do
Page 19: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Air Connections

– Replacement of Face Piece

Pull Nomex hood off of fire fighter’s head

Pull face piece away from face and up over the head

Turn on air at RIT face piece (purge valve or depress center)

Place RIT face piece to the face of fire fighter

Place netting over fire fighter’s head

Tighten down all five straps on face piece

Put Nomex hood back over fire fighter’s head

Page 20: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do
Page 21: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do
Page 22: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Packaging

Prior to attempting to remove a down fire fighter from a structure, the fire fighter should be packaged to facilitate an effective rescue

Page 23: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Packaging Start by tightening the shoulder strap

down and half hitching the straps

Page 24: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Packaging

Next tighten the waist strap

Lastly thread the shoulder strap of the RIT bag through the SCBA shoulder straps and attach it back to the RIT bag

The RIT Pack will ride on top of the fire fighter and in between the legs

– NOTE: placing the waist strap through the legs may not be possible the waist strap

Page 25: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Packaging

Page 26: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Review

How long is the EBSS Hose?

6 Feet

Page 27: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Review

How long is the UAC Hose?

5 Feet

Page 28: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Review

How long can it take for two cylinders to equalize pressures when using the UAC?

Approximately 30 seconds

Page 29: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Review

Name three ways to give a down fire fighter air with the RIT Pack III.

UAC Connection

EBSS connection to EBSS connection

EBSS to fire fighter’s regulator

Regulator change out

Face piece change out

Page 30: Scott RIT Pack III - Fauquier County Fire & Rescue - Homefcfra.camp9.org/Resources/Documents/SCBA/ScottRITPack III02-2012.pdf · If the down fire fighter's cylinder is damaged do

Questions?