Top Banner
ZenoTOF 7600 system EXTRAORDINARY BE The Zeno revolution is now… Introducing the SCIEX ZenoTOF 7600 system
16

SCIEX ZenoTOF 7600 system brochure - PUPIQ

Apr 09, 2023

Download

Documents

Khang Minh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: SCIEX ZenoTOF 7600 system brochure - PUPIQ

ZenoTOF 7600 system

EXTRAORDINARYBE

The Zeno revolution is now…Introducing the SCIEX ZenoTOF 7600 system

Page 2: SCIEX ZenoTOF 7600 system brochure - PUPIQ

2 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

ZenoTOF 7600 system A powerful leap in proprietary innovation, this high-resolution accurate mass system combines the power of Zeno trap pulsing with EAD fragmentation technology (electron activated dissociation) to unlock sensitivity gains that reveal new, rare, or even previously undetected information on an everyday basis. Detect up to 20x more ions in every experiment and access a spectrum of tunable fragmentation techniques to uncover new perspectives for every molecule, in every experiment.

Ion sourcesCompatible with advanced source designs that minimize contamination and allow you to obtain fast, automated calibrations across flow rate ranges.

Flow rate flexibility Turbo V source

– ESi 5µL/min to 3mL/min – APCI 200µL/min to 3mL/min Optiflow Turbo V

– µflow 1µL/min to 200µL/min – nano 100nL/min to 1,000nL/min

Software Powered by SCIEX OS mass spectrometry software, intuitive algorithms and automation enable you to make informed decisions quickly. Transform your LC-MS/MS workflows with remarkable quantitative usability, efficiency, and integrity that streamlines your entire lab.

Calibration delivery systemDesigned with a new calibration solution that automates mass calibration, and ensures mass accuracy of the system is maintained throughout acquisition.

Electron activated dissociationFine tune the fragmentation energies specific to your molecules of interest, and acquire key MS/MS features for large molecules, peptides, lipids and small molecules.

Zeno trap pulsing Gain more useful MS/MS information in every experiment, particularly on lower abundance species, with a 5-20x gain in MS/MS sensitivity coupled with either EAD or CID fragmentation.

Page 3: SCIEX ZenoTOF 7600 system brochure - PUPIQ

3 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

Overcome QTOF MS/MS duty cycle deficiencies >90% ions injected into the TOF

Sensitivity gains of up to 5-20x with Zeno trap pulsing Identify and quantify low abundance species

Tunable fragmentation of all molecule types Utilize controlled electron activated dissociation (EAD)

MS/MS scan rates of up to 133Hz Improved DDA and high resolution MRM (MRMRHR)

Zeno trap and EAD. A powerful combination of unparalleled MS/MS

sensitivity and a step-change in fragmentation technology. Together they

provide the ability to acquire key MS/MS features needed to:

Characterize large molecules including post-translational modifications

Elucidate positional isomers on small molecules and lipids

Identify and quantify proteins and peptides at unparalleled speed

The Zeno revolution is now...

3.2 3.4Time, min

0.0e0

1.0e5

2.0e5

3.0e5

4.0e5

5.0e5

6.0e5

7.0e5

8.0e5

9.0e5

1.0e6

Inte

nsity

, cps

100 150 200 250 300 350 400 450 500 550 600 650 700

Mass/Charge, Da

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

% In

tens

ity (o

f 137

19.0

)

Unique fragments for O-glucuronide

Figure 1. Impact of ions accumulated in the Zeno trap before being pulsed rapidly into the TOF both increases in sensitivity but also spectral quality.

Figure 2. Impact of EAD for singly charged molecules. Here shown is Darunavir-O-glucuronide, a phase 2 metabolite which is very difficult to structurally elucidate via CID because the glucuronide motif is lost as a neutral loss under CID conditions. Utilizing EAD produces diagnostic fragment ions to determine the location of the glucuronide.

100 200 300Mass/Charge, Da

0e0

1e5

2e5

3e5

Inte

nsity

, cps

100 200 300Mass/Charge, Da

0e0

1e4

2e4

3e4

Inte

nsity

, cps

Zeno EAD IDA of Darunavir-O-glucuronideZeno MRMHR cAMP

Zeno trap on

Zeno trap off

Page 4: SCIEX ZenoTOF 7600 system brochure - PUPIQ

4 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

A new mindset in accurate mass LC-MS/MS technologyDriven by the power of Zeno trap coupled with EAD technology, this fragment-centric revolution unlocks sensitivity gains allowing you to uncover new information, for more certainty in your results, and to make better-informed decisions, faster.

EAD cellHighly tunable Electron activated dissociation (EAD). EAD allows for a range of free electron- based fragmentation mechanisms within one device.

LINAC collision cellHigh drive frequency collision cell provides a better ion transmission, higher duty cycle, and improved resolution by focusing ions prior to entering TOF.

TOFN-optic TOF design provides optimal mass accuracy and resolution without compromising sensitivity.

Heated TOF path & drone heaters Mass Range: 40 to 40 kDa in TOF Resolution: ≥ 42k at m/z 956 MS/MS Speed: 133Hz Mass Accuracy: <2 ppm RMS Ext.,

<1 ppm RMS Int Positive & Negative LDR: >5 orders

Inter-scan LDR

Zeno trapImproved MS/MS duty cycle gain with 5-20x gain in MS/MS sensitivity coupled with either EAD or CID fragmentation.

Q0 Design Improved ion optics design for ion capture and transmission, with easy access for maintenance.

Page 5: SCIEX ZenoTOF 7600 system brochure - PUPIQ

5 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

Ions are accumulated in the Zeno trap before being pulsed rapidly into the TOF, meaning up to 20x more ions can be detected. Consequently, each TOF experiment contains more useful MS/MS information, particularly on lower abundance species that were previously undetectable, introducing our customers to a new level of sensitivity.

Zeno trapThe next era of sensitivity for accurate mass

Mass/Charge, Da

0

1200

2000

3000

4000

5000

6000

7000

8000

9000

10000

50 100 150 200 250 300 350 400 450

Mass/Charge, Da

Inte

nsity

, cps

Inte

nsity

, cps

0

1200

2000

3000

4000

5000

6000

7000

8000

9000

10000

50 100 150 200 250 300 350 400 450

With Zeno trap pulsingWithout Zeno trap pulsing

Page 6: SCIEX ZenoTOF 7600 system brochure - PUPIQ

6 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

The ability to tune electron kinetic energy extends the utility of the approach to all molecules type from singly charged small molecules to large multiply charged proteins. EAD allows for a range of reagent free electron- based fragmentation mechanisms within one device, and has the capability to fragment peptides whilst retaining critical MS/MS information for both identification and localisation of PTMs. Unlike other electron-based fragmentation techniques, EAD delivers reproducible, consistent data, even at fast scan speeds, compatible with UHPLC timeframes, delivering higher efficiency than ETD. In this instrument geometry coupling EAD with the Zeno trap allows for detection of very low abundant diagnostic fragment ion species leading to greater sequence coverage.

Electron activated dissociation (EAD)A step change in fragmentation technology

Figure 4. O-Glycosylation as shown requires comprehensive fragment coverage to confirm the glycan and also the site localization. Higher energy EAD (hot EAD) as shown for a complex O-glycopeptide shows near complete sequence coverage and both glycans localized in the centre portion of the peptide.

EAD fragmentation of an o-glycopeptide

0%

20%

40%

60%

80%

100%

10 100 1000

clea

vage

cov

erag

e

spectrum accumulation [ms]

activated

deactivated

Zeno pulsing

Page 7: SCIEX ZenoTOF 7600 system brochure - PUPIQ

7 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

Confident structural elucidation of xenobioticsThe ZenoTOF 7600 system brings a new level and depth of information to qualitative and quantitative workflows with electron activated dissociation. When combined with the Zeno trap comprehensive fragment coverage can be obtained to enable more confident structural elucidation.

The hardest challenge for CID is the fragmentation of phase 2 conjugated metabolites such as glucuronidation. EAD generates unique fragments which enables the differentiation of N- and O- Glucuronides which are otherwise lost during the CID fragmentation step and without the use of chemically synthesized standards, elucidation is rather challenging. With the EAD approach, 32 diagnostic fragments were detected this was possible because with the Zeno trap the signal is considerably enhanced. Therefore, the use of EAD is a step forward to improve productivity with fewer experiments needed.

Figure 5. The EAD Spectrum. EAD spectrum which produces an important fragment ion with the glucuronide preserved which allows localization of the glucuronide modification. Also, low mass fragment ions are preserved by using a QTOF-based platform.

100 150 200 250 300 350 400 450 500 550 600 650 700

Mass/Charge, Da

0%

50%

100%

100 150 200 250 300 350 400 450 500 550 600 650 700

Mass/Charge, Da

0%

50%

100%

O-glucuronide

Confirmatory fragmentrequired for full ID

Parent mass

Zeno CID

Zeno EAD

No low mass cut-off

NH2

SO

ON

CH3 CH3

O

O

O

O

NH

O

HH

H

O OH

OHOH

OHO

NH

CH3 CH3

O

O

O

O

NH

O

HH

H

O OH

OHOH

Darunavir-O-glucuronide

Darunavir-O-glucuronide fragment structure for confirmation

Page 8: SCIEX ZenoTOF 7600 system brochure - PUPIQ

8 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

100 150 200 250 300 350 400 450 500 550 600 650 700 750 800

Mass/Charge, Da

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

% In

tens

ity (o

f 5.0

e4)

Complete characterization of lipids in a single experimentLipids are a complex group of compounds with subtypes that share a similar high-level structure. For example, triglycerides consist of a glycerol group bonded to three long hydrocarbon chains with additional functional head groups attached in some cases. Small but meaningful differences between lipid species such as the location of a single double bond along the hydrocarbon chain can have important implications for health and disease. In one experiment, EAD provides all of the information for complete lipid characterization that normally requires multiple technologies and experiments.

Complete characterization of lipids involves the identification of:

Figure 6. Single experiment lipid characterization. The complete de novo identification and characterization of the lipid PC 16:0 / 18:1(n-9:cis) in a single experiment.

Fragmentation patternsSingle experiment lipid characterization

Head group Backbone

Regio-isomerism Double bonds

Cis/trans isomerism

1.

2.2.

500 520 540 560 580 600 620 640 660 680 700 720 740 760

Mass/Charge, Da

0.0%

0.1%

0.2%

0.3%

0.4%

0.5%

0.6%

0.7%

0.8%

0.9%

1.0%

1.1%

1.2%

1.3%

1.4%

1.5%

% In

tens

ity (o

f 5.0

e4)

3.

2.

3.

Backbone (glycerol/sphingoid) Regioisomerism (sn-1, sn-2, etc.)

Chain structure Length and double bonded positions Double bond stereochemistry

1. EAD produces diagnostic fragments of: Head group

- PC (SM), PE, PS, PI, PA, PG

H

OP

O

ON+O

O

O

O Osn-1

sn-2

Head group variations

2H 2H O O

saturated

unsaturated

mass difference

H

OP

O

ON+O

O

O

O Osn-1

sn-2

sn-1 has one more carbon than sn-2

Page 9: SCIEX ZenoTOF 7600 system brochure - PUPIQ

9 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

Differentiate between leucine and isoleucine in a single runSome amino acids are identical in mass, such as aspartic acid/isoaspartic acid and leucine/isoleucine making their differentiation impossible using CID. Zeno EAD however, can identify these isomers from additional fragment ions that are produced. For example, with leucine/ isoleucine secondary w-ion fragments caused by further fragmentation of the backbone z-ion can be used for identification to rapidly confirm primary structure in the production of biopharmaceuticals.

Key Benefit

Zeno EAD enables the differentiation of isomeric amino acids that otherwise

cannot be differentiated using conventional low energy CID.

Figure 7. EAD clearly indicates the identity of two leucine residues within this peptide sequence through the loss of 43 Da from the z6 and z13 ions. At the bottom, loss of 29 Da from the z5 ion identifies an isoleucine within this peptide sequence.

CH3 CH

R

O

CH3

R

O

CH3

CH2

CH3+

CH3

CH3

CH

R

O

CH2

R

O

CH3 CH

CH3+

Leucine

IsoleucineLeu z.6-43

Differentiation of leucine and isoleucine using ZenoEAD

Leu z.13-43

Ile z.5-29

Page 10: SCIEX ZenoTOF 7600 system brochure - PUPIQ

10 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

Straightforward localization of N-glycosylationGlycopeptides are the most common critical quality attribute for protein therapeutics. Glycosylation can affect; protein folding, protein stability, solubility and cell adhesion and therefore needs to be fully characterized to ensure the safety of biologic drugs. CID fragmentation typically misses the specific fragment ion critical for localizing the attachment point of a glyco group on the peptide backbone. In contrast, EAD spectra are dominated by these fragment ions, making localization straightforward.

As the mass difference between fragment ions on both sides of the attachment point enable calculation of the glycan molecular weight, both EAD and CID can be complementary for glycopeptide analysis.

Figure 8. EAD provides both peptide sequence and glycan localization (c9++ ion). Figure 9. CID only shows glycan loss or peptide backbone information, not both in same MS/MS spectrum in a descriptive manner; localization is not possible.

Zeno EAD IDA of an n-glycopeptide Zeno CID IDA of an n-glycopeptide

c9++

Page 11: SCIEX ZenoTOF 7600 system brochure - PUPIQ

11 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

Over 40% more proteins identified using Zeno MS/MSUtilizing high throughput micro flow methodologies, the ZenoTOF 7600 system breaks through the 3,000 protein groups in 21 minutes for the first time. Unique Zeno trap pulsing provides significant gains in peptide and protein identifications for proteomics experiments. Up to ~ 45% improvements in the number of protein IDs and up to a 145% increase in the number of peptide IDs, compared to previous TripleTOF technologies.

824 825 826 827

Mass/Charge, Da

0

100

200

300

400

Inte

nsity

, cps

824.87300.5013

1.0023

1.50422.0126

0

5000

10000

15000

20000

25000

30000

0

500

1000

1500

2000

2500

3000

3500

SCIEX ZenoTOF 7600 protein groups SCIEX ZenoTOF 7600 peptides

Num

ber o

f pro

tein

gro

ups

Num

ber o

f pep

tides

Gradient duration (min) 1000 ng

10 72%45 145%   

10 41%45 46%

Peptide Gains

Protein Gains

500 1000Mass/Charge, Da

0

100

200

300

400

Inte

nsity

, cps

b2

y13y13

b 3

y12

y12

b4 y11

y11

b5

y10

b6

y9

b7

y8

b8

y7

b9

y6b10

y5b11

y4b12

y3y2 b14

y1

Figure 10. Impact of using Zeno trap for IDA. The TOF MS is shown for a peptide at 25 ng sample load which was triggered for the Zeno MS/MS. The isotopic fidelity is shown up to the M+4 isotope.

Figure 11. The impact of the Zeno trap on CID IDA(DDA) over previous platforms is shown. Significant improvements in both peptide and protein numbers are observed at short and medium gradient lengths.

Figure 13. Routinely achieving high protein and peptide identifications at high throughput is difficult. The ZenoTOF 7600 system when coupled with a highly reproducible micro flow solution drives significant protein and peptide identifications breaking through >3,000 protein groups and >20,000 peptides using technical quadruplicates. * Evosep: Towards a Standardized Omics Platform with the 60 SPD https://www.evosep.com/wp-content/uploads/2020/06/AN-008-20-06_60SPD.pdf

Figure 12. Impact of using Zeno trap for IDA. The Zeno CID MS/MS is shown for the precursor in figure 10. For a low abundant precursor a high quality MS/MS for identification is acquired with near complete sequence coverage and excellent signal to noise.

Zeno DDA Peptide and protein gains

Peptide and protein IDs for HeLa at 500 ng on 60 SPD method*

Zeno MS/MS

Page 12: SCIEX ZenoTOF 7600 system brochure - PUPIQ

12 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

SWATH acquisition for higher throughput proteomicsThe ZenoTOF 7600 unlocks unprecedented speed for SWATH acquisition with variable windows, with scan rates up to 133Hz (133 MS/MS per second). This enables quantitative flexibility to match the throughput demands of translational proteomics. Higher throughput proteomics requires accurate, precise and reproducible quantification of all analytes, at all concentrations.

Figure 14. The step to 5 minute gradients at 200 samples per day for quantification requires high acquisition rates for MS/MS to maintain the number of data points at all concentrations. Shown is 20 ng of a K562 digest for the peptide YYVTYYDAPGHR.

Figure 15. Continuation from figure 14, is a high load at 500ng of a K562 digest with the peptide YYVTYYDAPGHR extracted.

Figure 16. The ZenoTOF 7600 system shows excellent protein group coverage and 20% CV cutoff quantified proteins in just 5 minutes utilizing the 200 SPD method.

Figure 17. The ZenoTOF 7600 system shows excellent peptide coverage and 20% CV cutoff quantified peptides in just 5 minutes utilizing the 200 SPD method.

SWATH MS/MS at 500 ng load on 200 SPD method

K562 proteins identified and quantified using 200 SPD method K562 peptides identified and quantified using 200 SPD method

2.5 2.6 2.7Time, min

0

1000

2000

3000

4000

5000

Inte

nsity

9 data points

2.5 2.6Time, min

0.0e0

2.0e4

4.0e4

6.0e4

8.0e4

1.0e5

Inte

nsity

9 data points

0

500

1000

1500

2000

2500

3000

3500

20ng 50ng 200ng 500ng

Protein groups ID <20% CV

Num

ber o

f pro

tein

gro

ups

0

5000

10000

15000

20000

25000

20 ng 50 ng 200 ng 500 ng

Peptides <20% CV

Num

ber o

f pep

tides

SWATH MS/MS at 20 ng load on 200 SPD method

Page 13: SCIEX ZenoTOF 7600 system brochure - PUPIQ

13 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

Zeno MRMHR unlocks new levels of sensitivityZeno trap pulsing on demand gives the ability to detect lower abundance ions at the same times as those in abundance, redefining the limits of quantification achievable with accurate mass. MRMHR is a targeted approach that delivers high sensitivity and selectivity for screening and targeted quantification.

3.05 3.10 3.15 3.20 3.25 3.30 3.35Time, min

0e0

2e5

4e5

6e5

8e5

Inte

nsity

, cps

2.8 3.0 3.2 3.4 3.6 3.8

Time, min

0

100

200

Inte

nsity

, cps

Figure 18. Targeted metabolite quantification - Significant sensitivity gains in MS/MS. Comparison of extraction ion chromatograms (XICs) for cAMP fragments obtained from MS/MS collect with Zeno trap on vs. Zeno trap off. Signal/noise ratio improved ~12.5 fold when using the Zeno trap.

Figure 19. Targeted peptide quantification - Significant sensitivity gains in MS/MS. Comparison of extraction ion chromatograms (XICs) for LILTLTHGTAVC[CAM]TR fragments obtained from MS/MS collected with Zeno trap on vs. Zeno trap off. Signal/noise ratio improved ~8 fold when using the Zeno trap.

Figure 20. Better sensitivity in MS/MS with 10x less sample. Comparison of extraction ion chromatograms for cAMP fragments obtained from MS/MS collect with Zeno trap on (0.2 µL injection) vs. Zeno trap off (2 µL injection).

Figure 21. Better sensitivity in MS/MS with 8x lower concentration. Comparison of XICs for LILTLTHGTAVC[CAM]TR fragments obtained from MS/MS collect with Zeno trap on vs. Zeno trap off. Zeno trap off at 6.18ng/mL and Zeno trap on at 0.757 ng/mL.

3.05 3.10 3.15 3.20 3.25 3.30 3.35Time, min

0.0e0

2.0e4

4.0e4

6.0e4

8.0e4

1.0e5

1.2e5

Inte

nsity

, cps

2.8 3.0 3.2 3.4 3.6 3.8Time, min

0

500

1000

1500

Inte

nsity

, cps

Small molecule Peptide quantification

Page 14: SCIEX ZenoTOF 7600 system brochure - PUPIQ

14 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

Software that powers the modern laboratory

Audit Trail

Event Log

Library

Configuration

Analytics

Explorer

MS Tune

LC Method

MS Method

QueueBatch

Acquisition ManagementProcessing

The SCIEX ZenoTOF 7600 system is powered by SCIEX OS software. Fully integrated software that acquires, processes and reports your accurate mass data. Since it’s launch SCIEX OS has continued to evolve it’s functionality to meet the ever expanding challenges and opportunities of analytical science.

Consistency, accuracy and connectivity are present throughout all workspaces of SCIEX OS. Powerful algorithms and automation that will enable you to cut through complexity, straight to insight. SCIEX OS streamlines your lab delivering high-quality, actionable data for a wide range of applications,

One platform for acquisition, processing and data management

Simple user interface, modular design tiles Method development becomes routine and easily transferable

Customizable for specific workflow requirements

“ In new innovations the software is key, as the software enables the creation of results. Software that integrates data acquisition, processing, interrogation and reporting gives added value in terms of efficiency with which these results can be generated.”

LIEVE DILLENSenior Principal Scientist for Assay Development and Analytical Support, Development Bioanalysis group, Janssen R&D, Belgium

Page 15: SCIEX ZenoTOF 7600 system brochure - PUPIQ

15 | SCIEX | ZenoTOF 7600 system | Be Extraordinary SCIEX.com/zenorevolution

Delivering insightSoftware is the vital connector between technology and insights that will drive discovery. Whether you are characterizing potentially complex proteins, routinely screening, or quantifying modalities in complex matrices they each require advanced data processing technologies to interrogate data and deliver actionable insight. The SCIEX ZenoTOF 7600 system is powered by a suite of software tools that will make these discoveries within your existing data pipeline.

Third Party software compatibility:

SCIEX OS software empowers you with more than just

processing. Take advantage of automated functionality, library

management and audit trails for compliance. All the tools you

need for any LC-MS/MS workflow, from routine to the most

complex, in a single location.

Big data needs the power of the cloud to process it. Whether

you are conducting proteomics, metabolomics or genomics

research the SCIEX OneOmics suite has the power, precision, and

capacity to derive insight from large multi-omics cohorts. One cloud. Countless opportunities.

OneOmics

Molecule Profiler delivers a highly accurate and flexible workflow for impurities and

biotransformations for a wide variety of therapeutic molecules,.

Built into the architecture of SCIEX OS mass spectrometry

software, Molecule Profiler ensures a seamless acquisition and data analysis experience.

Visit SCIEX OS site Visit OneOmics suite site Visit Molecule Profiler site

Page 16: SCIEX ZenoTOF 7600 system brochure - PUPIQ

The SCIEX clinical diagnostic portfolio is For In Vitro Diagnostic Use. Rx Only. Product(s) not available in all countries. For information on availability, please contact your local sales representative or refer to https://sciex.com/diagnostics. All other products are For Research Use Only. Not for use in Diagnostic Procedures. Trademarks and/or registered trademarks mentioned herein, including associated logos, are the property of AB Sciex Pte. Ltd. or their respective owners in the United States and/or certain other countries (see sciex.com/trademarks). © 2021 DH Tech. Dev. Pte. Ltd. RUO-MKT-07-13304-A

Headquarters500 Old Connecticut PathFramingham, MA 01701 USAPhone 508-383-7700sciex.com

International SalesFor our office locations please call the division headquarters or refer to our website atsciex.com/offices

SCIEX Now support network

SCIEX Now

Manage your instruments.

Submit and manage support cases, track status and history.

Access online training courses and articles.

Manage software licenses linked to your registered instruments.

View and report critical instrument statistics when connected to StatusScope Remote Monitoring.

Be a part of the SCIEX community by submitting questions and comments.

Receive notifications from SCIEX with content based on your preferences.

SCIEX University

SCIEX University Success Programs provide LC-MS

and CE training customized to meet your exact needs.

With a selection of training methods and certifications

available, you can build a mass spectrometry program

that is most suited to your lab and users.

Starting with a clear understanding of your desired

learning outcomes, we aim to help you improve lab

productivity and consistency by designing and

delivering a program that is focused on knowledge

advancement and retention.