Transcript
Page 1: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric: Total Cooling Solutions for Data Centers

Nestor Hugo Salinas, ATD #

Solution Architect

Page 2: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 2

Power Flow in a Typical Data Center

41% Cooling

PUE = 2.13DCiE= 47%Source:

WP # 126: An improved architecture for high efficiency, high density data center

Page 3: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 3

Data Center Cooling Trends

• Close Coupled Cooling• Higher Temperature Operation• Free Cooling• Evaporative or Adiabatic Cooling• Containment Cooling• Chimney Racks and Ceiling Plenums• Dew Point Humidity Control• Non-integrated Humidification• Intelligent Management Systems

Efficiency

Increased Temperatures

Economizers

Page 4: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 5

3 Cooling Architectures

Source:WP # 130: The advantages of row and rack oriented cooling architectures for data centers

** NMX-J-C-I-489-ANCE-ONNCE –NYCE-2014

• Rack density**:• Low: up to 3 kW• Medium: 3kW < X < 8kW• High: 8kW < X < 15kW• Extreme: >15kW

Page 5: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 6

Hibryd Cooling Solutions

Overhead CoolingRow Cooling

Room CoolingNeutral Containment

Chillers

Heat rejection

Page 6: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 7

How can we help you

Page 7: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 8

Design tools:Configuration – ISX Designer

● Directions:● Contact APC Sales● Engage Local Representative● APC implements requirements

with pre-tested solutions from configurator

● APC Configuration team addresses unique requirements

Page 8: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 9

Design tools: StruxureWare - EcoStream

Page 9: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 10

Improve Performance: Air Distribution

Page 10: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 11

Low density: Room Cooling

• DX and CW• 20 – 100 kW DX units• 20 – 190 kW CW units

• High Effiency

• EC Fans technology

• Frontal Access

• R410A refrigerant

• Electronic Expansion Valve integrated with Uniflair control

• Tandem compressors to increase unit efficiency at partial loads

• Energy Saving and Twin versions

• 208V and 480V

http://www.uniflair.com/coolingfordatacenter/

Page 11: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 12

Medium / High Density: Row Cooling

http://www.uniflair.com/coolingfordatacenter/

Page 12: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 13

InRow® Cooling Leader

InRow® Chilled Water InRow® Direct Expansion

Page 13: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

14Schneider Electric

InRow® Cooling Overhead

• InRow® Pumped Refrigerant R134A

• White Space is not required

• Up to 27kW per unit

• Up to 160kW per system

• High Availability

Page 14: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

15Schneider Electric

High / Extreme density: EcoAisle®

• Options available to support (900mm, 1200mm,1500mm, and 1800mm aisle widths )

• Panels Can also be modified in the field to fit odd aisle sizes

• Ceiling panels support hot or cold aisles

• Safe Slide Doors support hot or cold aisles

• Blank Panels available for 300, 600, 700, and 750mm wide spaces

http://www.uniflair.com/coolingfordatacenter/

Page 15: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

16Schneider Electric

EcoAisle options

• Ducted hot/cold aisle• Fire safe System• LED Lighting • Curtain / Sliding safe Door

Page 16: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

17Schneider Electric

EcoAisle Fire Safe System

Page 17: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

18Schneider Electric

High / Extreme density: Rack Containment

Page 18: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 19

Indirect Free Cooling - EcoBreeze®An Indirect Evaporative Air-Side Economizer with typical

partial PUE of 1.09 to 1.20

Page 19: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 20

Free Cooling - EcoBreeze®

Page 20: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 22

Close Control Air Conditioning for Mobile Telecommunications

• Easy & quick installation• Refrigerant charged in factory• Complete final testing of unit in factory• Reduced installation time • Reliable and trouble-free operation • SCROLL compressor• Low noise operation

• R407C or R134a refrigerant

• Supervision system:

• via serial line RS485 – TCP/IP

Page 21: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 23

Mobile Telecom units – Product Range

Page 22: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 24

Chiller Water Units• R410A & R134a refrigerant• Electronic Expansion Valve integrated with Uniflair control• EC Fans (Electronic Commutation)• Free Cooling• Tandem Compressors

• Inverter driven scroll compressors• Centrifugal compressors• Double Screw compressors

Page 23: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 25

0

200

400

600

800

1000

1200

kW

Chiller Water units: Product Range

Page 24: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 26

Prefabricated Solutions

Page 25: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric 27

Schneider Electric Cooling Portfolio

RowR

ack

•Amico•Leonardo•Wall-mounted•Monoblock•Gemini•Unisplit•InRoom SC •Room Air Distribution

•Rack Air Distribution

•InRack Direct Expansion

•Chimeneas

•InRow Chilled Water

•InRow Direct Expansion

•InRow OA/RA Pumped Refrigerant

•Thermal Containment

•Access Flooring•Technical Chillers•Free Cooling, Chillers and Economizers

•Ecoflair®•Heat RejectionRoom

Page 26: Schneider Electric: Total Cooling Solutions for Data Centers Nestor Hugo Salinas, ATD # Solution Architect.

Schneider Electric

Make the most of your energy™