VERTICAL NOTCHES OF SENERGY ADHESIVE / BASE COAT APPLIED TO APPROVED EPS INSULATION BOARD APPROVED EPS INSULATION BOARD 1/2" (13mm) 2" (50mm) 1/2" (13mm) 01 TYPICAL ADHESIVE PATTERN Structure, substrates, flashing, and other items which are not part of the BASF Senergy Channeled Adhesive CI Design system are the responsibility of others. This detail is subject to change without notice. BASF Corporation - Wall Systems (herein after BASF Wall Systems) accepts no liability for the end use of this detail. For conditions not shown, consult BASF Wall Systems for review of specific detail. NTS SCALE: SENERGY CHANNELED ADHESIVE CI DESIGN REV 180205
36
Embed
SCALE: NTS 01 · This detail is subject to change without notice. BASF Corporation - Wall Systems (herein after BASF Wall Systems) accepts no liability for the end use of this detail.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
VERTICAL NOTCHES OF SENERGYADHESIVE / BASE COAT APPLIED TOAPPROVED EPS INSULATION BOARD
APPROVED EPS INSULATION BOARD
1/2" (13mm)
2" (50mm) 1/2" (13mm)
01
TYPICAL ADHESIVE PATTERN
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
APPROVED EPS INSULATION BOARD
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R;-RS;-VBOR WS FLASH W/ FLASHING PRIMER
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
FRAMING
*BY OTHERS
02
TYPICAL APPLICATION
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
CMU*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R;-RS;-VB,OR WS FLASH W/ FLASHING PRIMER
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
FLASHING*
*BY OTHERS
03
TYPICAL APPLICATION OVER CMU
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
BRICK*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R;-RS;-VB,OR WS FLASH W/ FLASHING PRIMER
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
FLASHING*
*BY OTHERS
04
TYPICAL APPLICATION OVER BRICK
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
MIN. 3/4" (19MM)
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
SENERGY ADHESIVE/ BASE COAT
APPROVED EPS INSULATION BOARD
SENERGY FINISH COAT
FLEXGUARD 4, INTERMEDIATE 6 ORINTERMEDIATE 12 REINFORCING MESHEMBEDDED IN SENERGY BASE COAT
CORNER MESH EMBEDDED INSENERGY BASE COAT
*BY OTHERS
NOTE: A CONTINUOUS OVERLAY OFFLEXGUARD 4, INTERMEDIATE 6, ORINTERMEDIATE 12 IS REQUIRED OVERCORNER MESH
06
TYPICAL CORNER MESH APPLICATION
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180702
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
ACCEPTABLE SHEATHING*
SET FLANGE IN SEALANTOR PROVIDE GASKET*
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
BACKER ROD AND SEALANT*
LIGHT FIXTURE*
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180702
SEALANT*
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
*BY OTHERS
09
TYPICAL VERTICAL EXPANSION JOINT DETAIL
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
FRAMING*
ACCEPTABLE SUBSTRATE*
ACCEPTABLE SHEATHING*
WS FLASH WITH FLASHING PRIMER
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
APPROVED EPS INSULATION BOARD
BASF COLOR COAT(OPTIONAL)
BACKER ROD & SEALANT(WIDTH PER DESIGN)*
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
FLOOR SLAB*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
FLOOR SLAB*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R;-RS;-VB,OR WS FLASH W/ FLASHING PRIMER
ACCEPTABLE SHEATHING*
WS FLASH WITH FLASHING PRIMER
FLASHING*
BACKER ROD & SEALANT(WIDTH PER DESIGN)*
BASF COLOR COAT(OPTIONAL)
APPROVED EPS INSULATION BOARD
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
*BY OTHERS
12
TYPICAL DRAINAGE AT FLOORLINE
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
FRAMING*
ACCEPTABLE SHEATHING*
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
MAXFLASH, SHEATHING FABRIC EMBEDDEDIN SENERSHIELD-R;-RS;-VB, OR WS FLASHW/ FLASHING PRIMER
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
BACKER ROD & SEALANT*(WIDTH PER DESIGN)*
WS FLASH WITH FLASHING PRIMER
BRICK*
*BY OTHERS
13
TYPICAL ABUTMENT TO BRICK WITH DRAINAGE AT FLOORLINE
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
FRAMING*
ACCEPTABLE SHEATHING*
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
BACKER ROD & SEALANT(WIDTH PER DESIGN)*
BRICK*
*BY OTHERS
14
TYPICAL CHANNELED ADHESIVE CI DESIGN ABUTMENT TO BRICK
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
FRAMING*
ACCEPTABLE SHEATHING*
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
SENERSHIELD-R/SENERSHIELD-RS /SENERSHIELD-VB
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R; -RS; -VB,OR WS FLASH W/ FLASHING PRIMER
NOTE:TERMINATE SENERGY CHANNELEDADHESIVE CI DESIGN SYSTEM MIN.8" (203 mm) ABOVE GRADE
MIN: 2" (50mm)MAX: 12" (305mm)
15
TYPICAL TERMINATION AT FOUNDATION
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
FRAMING*
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
APPROVED EPS INSULATION BOARD
SENERGY LAMINA:SENERGY BASE COATSENERGY REINFORCING MESHSENERGY FINISH COAT
WS FLASH W/ FLASHING PRIMER
WRAP BASE COAT ANDSENERGY REINFORCING MESH
BACKER ROD AND SEALANT(WIDTH PER DESIGN)*
WEEP TUBE*
FOUNDATION*
*BY OTHERS
16
TYPICAL TERMINATION AT FOUNDATION (FLUSH)
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
APPROVED EPS INSULATION BOARD
SENERGY LAMINA:SENERGY BASE COATSENERGY REINFORCING MESHSENERGY FINISH COAT
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R; -RS; -VB,OR WS FLASH W/ FLASHING PRIMER
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
FLASHING*
SEALANT*
WINDOW*
*BY OTHERS
NOTE: WRAP MAXFLASH, SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R; -RS; -VB OR WS FLASH W/ FLASHING PRIMER INTO ROUGH OPENING ON HEAD IF ALSO INTENDED TO BE AN AIR BARRIER.
17
TYPICAL WINDOW HEAD (FLUSH)
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180702
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
SENERGY ADHESIVE/ BASE COATAPPLIED TO EPS INSULATION BOARD
APPROVED EPS INSULATION BOARD
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R; -RS; -VB,OR WS FLASH W/ FLASHING PRIMER
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
BASF COLOR COAT(OPTIONAL)
BACKER ROD & SEALANT W/WEEP TUBES AT MAX .16" O.C.*
FLASHING*
SEALANT*
WINDOW*
*BY OTHERS
NOTE: WRAP MAXFLASH, SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R; -RS; -VB OR WS FLASH W/ FLASHING PRIMER INTO ROUGH OPENING ON HEAD IF ALSO INTENDED TO BE AN AIR BARRIER.
18
TYPICAL WINDOW HEAD (FLUSH) WITH WEEP TUBES
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180702
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
SENERGY ADHESIVE/ BASE COATAPPLIED TO EPS INSULATION BOARD
APPROVED EPS INSULATION BOARD
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R; -RS; -VB,OR WS FLASH W/ FLASHING PRIMER
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
BASF COLOR COAT(OPTIONAL)
BACKER ROD & SEALANT(WIDTH PER DESIGN)*
WINDOW*
*BY OTHERS
NOTE: WRAP MAXFLASH, SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R; -RS; -VB OR WS FLASH W/ FLASHING PRIMER INTO ROUGH OPENING ON HEAD IF ALSO INTENDED TO BE AN AIR BARRIER.
19
TYPICAL WINDOW HEAD (FLUSH) WITH DIVERTER TRACK
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180702
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-VB/SENERSHIELD-RS
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R; -RS; -VB,OR WS FLASH W/ FLASHING PRIMER
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
ACCEPTABLE SEALANTAS END DAM*
FLASHING*
SEALANT*
WINDOW*
*BY OTHERS
20
TYPICAL WINDOW HEAD FLASHING W/ SEALANT END DAM
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180702
NOTE: WRAP MAXFLASH, SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R; -RS; -VB OR WS FLASH W/ FLASHING PRIMER INTO ROUGH OPENING ON HEAD IF ALSO INTENDED TO BE AN AIR BARRIER.
ACCEPTABLE SHEATHING*
APPROVED EPS INSULATION BOARD
FRAMING*
ADHESIVE / BASE COAT APPLIED TOEPS INSULATION BOARD
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
SENERGY LAMINA:SENERGY BASE COATSENERGY REINFORCING MESHSENERGY FINISH COAT
BASF COLOR COAT(OPTIONAL)BACKER ROD AND SEALANT(WIDTH PER DESIGN)*WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R;-RS;-VB, ORWS FLASH w/ FLASHING PRIMER
WINDOW*
*BY OTHERS
21
TYPICAL WINDOW JAMB (FLUSH)
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180702
WINDOW*
BACKER ROD AND SEALANT(WIDTH PER DESIGN)*
BASF COLOR COAT(OPTIONAL)
SENERGY LAMINA:SENERGY BASE COATSENERGY REINFORCING MESHSENERGY FINISH COAT
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R;-RS;-VB,OR WS FLASH 9 w/ FLASHING PRIMER
APPROVED EPS INSULATION BOARD
SENERGY ADHESIVE / BASE COATAPPLIED TO EPS INSULATION BOARD
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
ACCEPTABLE SHEATHING*
FRAMING*
*BY OTHERS
22
TYPICAL WINDOW SILL DETAIL (FLUSH)
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
SENERGY ADHESIVE / BASE COATAPPLIED TO EPS INSULATION
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
APPROVED EPS INSULATION BOARD
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
SENERGY LAMINA:SENERGY BASE COATSENERGY REINFORCING MESHSENERGY FINISH COAT
BACKER ROD AND SEALANT(WIDTH PER DESIGN)*
WINDOW*
*BY OTHERS
23
TYPICAL WINDOW HEAD (RECESSED)
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180702
NOTE: WRAP MAXFLASH, SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R; -RS; -VB OR WS FLASH W/ FLASHING PRIMER INTO ROUGH OPENING ON HEAD IF ALSO INTENDED TO BE AN AIR BARRIER.
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
APPROVED EPS INSULATION BOARD
SENERGY ADHESIVE / BASE COATAPPLIED TO EPS INSULATION BOARD
SENERGY LAMINA:SENERGY BASE COATSENERGY REINFORCING MESHSENERGY FINISH COAT
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R;-RS;-VB,OR WS FLASH w/ FLASHING PRIMER
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
BASF COLOR COAT(OPTIONAL)
BACKER ROD AND SEALANT*(WIDTH PER DESIGN)*
WINDOW*
*BY OTHERS
24
TYPICAL WINDOW JAMB (RECESSED)
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
WINDOW*
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R;-RS;-VB, ORWS FLASH W/ FLASHING PRIMER
PAN FLASHING W/ END DAMS*
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
APPROVED EPS INSULATION BOARD
SEALANT*
SENERGY LAMINA:SENERGY BASE COATSENERGY REINFORCING MESHSENERGY FINISH COAT
SENERGY ADHESIVE/ BASE COATAPPLIED TO EPS INSULATION BOARD
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
ACCEPTABLE SHEATHING*
FRAMING*
25
TYPICAL WINDOW SILL DETAIL (RECESSED)
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
*BY OTHERS
NOTE: -EXTEND FLASHING MIN 2" (50 mm) OVER CHANNELED ADHESIVE CI DESIGN -FLASHINGS ARE BY OTHERS AND SHALL BE AS PER DESIGN / CODE REQUIREMENT
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R; -RS; -VB,OR WS FLASH W/ FLASHING PRIMER
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
BACKER ROD AND SEALANT*(WIDTH PER DESIGN)
WINDOW*
*BY OTHERS
26TYPICAL FLANGED WINDOW HEAD
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180702
NOTE: WRAP MAXFLASH, SHEATHING FABRIC EMBEDDED IN SENERSHIELD-R; -RS; -VB OR WS FLASH W/ FLASHING PRIMER INTO ROUGH OPENING ON HEAD IF ALSO INTENDED TO BE AN AIR BARRIER.
ACCEPTABLE SHEATHING*
APPROVED EPS INSULATION BOARD
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R; -RS; -VB,OR WS FLASH W/ FLASHING PRIMER
BACKER ROD AND SEALANT(WIDTH PER DESIGN)*WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
WINDOW*
*BY OTHERS
27TYPICAL FLANGED WINDOW JAMB
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
WINDOW*MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R; -RS; -VB,OR WS FLASH W/ FLASHING PRIMER
BACKER ROD AND SEALANT(WIDTH PER DESIGN)*WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESHACCEPTABLE SHEATHING*
APPROVED EPS INSULATION BOARD
SENERGY ADHESIVE/BASE COATAPPLIED TO EPS INSULATION BOARD
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180702
ROOF SYSTEM*
METAL COPING*
EXTEND SHEATHING FABRIC EMBEDDEDIN SENERSHIELD-R;-RS;-VB, MAXFLASHOR WS FLASH W/ FLASHING PRIMERONTO BOTTOM & FACE OF BLOCKING
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
SEALANT*
SENERGY LAMINA:SENERGY BASE COATSENERGY REINFORCING MESHSENERGY FINISH COAT
APPROVED EPS INSULATION BOARD
SENERGY ADHESIVE / BASE COATAPPLIED TO EPS INSULATION BOARD
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
ACCEPTABLE SHEATHING*
FRAMING*
*BY OTHERS
MIN 2" (50 mm)
29
TYPICAL METAL COPING DETAIL
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180702
EPS CAP
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R;-RS;-VB,OR WS FLASH w/ FLASHING PRIMER
SENERGY LAMINA:SENERGY BASE COATSENERGY REINFORCING MESHSENERGY FINISH COAT
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
APPROVED EPS INSULATION BOARD
SENERGY ADHESIVE / BASE COATAPPLIED TO EPS INSULATION BOARD
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
ACCEPTABLE SHEATHING*
FRAMING*
SEALANT*
FLASHING*
ROOF COUNTER FLASHING*
*BY OTHERS
12"
6"
30
TYPICAL PARAPET CAP DETAIL
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
MIN 1" (25 mm )
12"
6"
MIN. 8" (203 mm)ABOVE ROOF
ACCEPTABLE SUBSTRATE*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R; -RS; -VB,OR WS FLASH W/ FLASHING PRIMER
SENERGY ADHESIVE/ BASE COATAPPLIED TO EPS INSULATION BOARD
APPROVED EPS INSULATION BOARD
BACKER ROD & SEALANT*
STEP FLASHING*
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
ROOF EDGE FLASHING*
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
SEALANT*
SENERGY LAMINA:SENERGY BASE COATSENERGY REINFORCING MESHSENERGY FINISH COAT
APPROVED EPS INSULATION BOARD
SENERGY ADHESIVE / BASE COATAPPLIED TO EPS INSULATION BOARD
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
ACCEPTABLE SHEATHING*
FRAMING*
*BY OTHERS
MIN. 2" (50MM)
32
TYPICAL ROOF EDGE FLASHING DETAIL
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180702
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
SENERGY ADHESIVE/ BASE COATAPPLIED TO EPS INSULATION BOARD
MAXFLASH, SHEATHING FABRICEMBEDDED IN SENERSHIELD-R;-RS;-VB,OR WS FLASH W/ FLASHING PRIMER
APPROVED EPS INSULATION BOARD
SENERGY LAMINA:SENERGY BASE COATSENERGY REINFORCING MESHSENERGY FINISH COAT
WRAP BASE COAT ANDSENERGY REINFORCING MESH
FLASHING*
SEALANT*
ACCEPTABLE SHEATHING*
SENERGY LAMINA:SENERGY BASE COATSENERGY REINFORCING MESHSENERGY FINISH COAT
*BY OTHERS
33
TYPICAL SECTION AT FASCIA / SOFFIT
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
WRAP SENERGY BASE COAT ANDSENERGY REINFORCING MESH
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
APPROVED EPS INSULATION BOARD
ACCEPTABLE SUBSTRATE*
*BY OTHERS
12" MIN.6" MIN.
34
TYPICAL CORE MOUNTED RAILING ATTACHMENT
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180702
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
ADHESIVE/ BASE COAT APPLIED TOEPS INSULATION BOARD
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.
NTSSCALE:SENERGY CHANNELED ADHESIVE CI DESIGN
REV 180205
FRAMING*
ACCEPTABLE SHEATHING*
SENERSHIELD-R/SENERSHIELD-RS/SENERSHIELD-VB
ADHESIVE/ BASE COAT APPLIED TOEPS INSULATION BOARD
Structure, substrates, flashing, and other items which are not part of the BASF SenergyChanneled Adhesive CI Design system are the responsibility of others. This detail is subjectto change without notice. BASF Corporation - Wall Systems (herein after BASF WallSystems) accepts no liability for the end use of this detail. For conditions not shown, consultBASF Wall Systems for review of specific detail.