Top Banner
SECTION V SANITARY SEWER
42

Sanitary Sewerage SDCSection5

Sep 29, 2015

Download

Documents

fatinaainaa

This is standard sanitary sewer details which can be use for consultants and students as their reference.
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • SECTION V

    SANITARY SEWER

  • TOC-V.1 of 2

    Published: 01/01 Revised:

    TABLE OF CONTENTS

    STANDARD SANITARY SEWER DETAILS

    No. Title

    S-1 Repaving Trenches and Payment Quantities

    S-1A Trench Details for Flowable Fill

    S-1B Temporary Pavement, Trench Details and Crusher Run Stone Payment Quantities

    S-2 Trenches Cradle and Encasement

    S-3 Building Sewer Layout

    S-4 Typical Air Test Detail for Building Sewer

    S-5 Standard House Connections

    S-6 Type C Connections

    S-7 Alternate Type C Connection Precast Wye

    S-8 Saddle Installation Detail Mainline Sewer to 4" House Connection

    S-9 Standard Cleanout

    S-10 Cleancut cover Assembly for All Paved Areas

    S-11 Standard Precast manhole

    S-12 Shallow Precast Manhole

    S-13 Drop Manhole Type A

    S-14 Drop Manhole Type B

    S-15 Alternate Drop Manhole Precast Base and Collars

    S-16 Terminal Manhole

    S-17 Standard Heavy Traffic Manhole Frame and Cover

    S-18 Standard Watertight Frame and Cover

  • TOC-V.2 of 2

    Published: 01/01 Revised:

    TABLE OF CONTENTS

    STANDARD SANITARY SEWER DETAILS

    No. Title

    S-19 Concrete collar for Manhole Frame and Cover

    S-20 Adjustment Grade Ring

    S-21 Standard Manhole Steps

    S-22 Flexible Pipe to Manhole Connection

    S-23 Waterstop Pipe to Manhole Connection for Steep Grades

    S-24 Air Release and Vacuum Valve in Manhole

    S-25 New Manhole Over Existing Pipe

    S-26 Abandonment of Pipe at Manhole

    S-27 Complete Manhole Abandonment

    S-28 Pressure Sewer Blocking Details

    S-29 Low Pressure Sewer and House Connection Blocking Details for Caps and Plugs

    S-30 Anchoring Pressure Sewers (Upper Vertical Bends)

    S-31 Air Test Requirements 6" and 8" Sewers with 4" Laterals

    S-32 Air Test Requirements 10" and 12" Sewers with 4" Laterals

    S-33 Air Test Requirements 15" and 18" Sewers with 4" Laterals

    S-34 Air Test Requirements 21" and 24" Sewers with 4" Laterals

    S-35 Air Test Requirements 4" through 24" Sewers without Laterals

    S-36 Concrete Anchor (When Pipe Slopes Exceed 20)

    S-37 Trench Erosion Check (For use in granular soils)

  • V-1 of 39

    Published: 01/01 Revised:

  • V-2 of 39

    Published: 01/01 Revised:

  • V-3 of 39

    Published: 01/01 Revised:

  • V-4 of 39

    Published: 01/01 Revised:

  • V-5 of 39

    Published: 01/01 Revised:

  • V-6 of 39

    Published: 01/01 Revised:

  • V-7 of 39

    Published: 01/01 Revised:

  • V-8 of 39

    Published: 01/01 Revised:

    S 6

  • V-9 of 39

    Published: 01/01 Revised:

  • V-10 of 39

    Published: 01/01 Revised:

    S 8

  • V-11 of 39

    Published: 01/01 Revised:

  • V-12 of 39

    Published: 01/01 Revised:

  • V-13 of 39

    Published: 01/01 Revised:

  • V-14 of 39

    Published: 01/01 Revised:

  • V-15 of 39

    Published: 01/01 Revised:

    S/11

  • V-16 of 39

    Published: 01/01 Revised:

  • V-17 of 39

    Published: 01/01 Revised:

    S 15

  • V-18 of 39

    Published: 01/01 Revised:

    S 16

    S/20

  • V-19 of 39

    Published: 01/01 Revised:

  • V-20 of 39

    Published: 01/01 Revised:

    S 18

  • V-21 of 39

    Published: 01/01 Revised:

  • V-22 of 39

    Published: 01/01 Revised:

  • V-23 of 39

    Published: 01/01 Revised:

  • V-24 of 39

    Published: 01/01 Revised:

  • V-25 of 39

    Published: 01/01 Revised:

  • V-26 of 39

    Published: 01/01 Revised:

  • V-27 of 39

    Published: 01/01 Revised:

  • V-28 of 39

    Published: 01/01 Revised:

  • V-29 of 39

    Published: 01/01 Revised:

  • V-30 of 39

    Published: 01/01 Revised:

  • V-31 of 39

    Published: 01/01 Revised:

  • V-32 of 39

    Published: 01/01 Revised:

  • V-33 of 39

    Published: 01/01 Revised:

  • V-34 of 39

    Published: 01/01 Revised:

  • V-35 of 39

    Published: 01/01 Revised:

  • V-36 of 39

    Published: 01/01 Revised:

  • V-37 of 39

    Published: 01/01 Revised:

  • V-38 of 39

    Published: 01/01 Revised:

  • V-39 of 39

    Published: 01/01 Revised:

    COVER PAGETABLE OF CONTENTSS-1Repaving Trenches and Payment QuantitiesS-1ATrench Details for Flowable FillS-1BTemporary Pavement, Trench Details and Crusher Run Stone Payment QuantitiesS-2Trenches Cradle and EncasementS-3Building Sewer LayoutS-4Typical Air Test Detail for Building SewerS-5Standard House ConnectionsS-6Type C ConnectionsS-7Alternate Type C Connection Precast WyeS-8Saddle Installation Detail Mainline Sewer to 4" House ConnectionS-9Standard CleanoutS-10Cleancut cover Assembly for All Paved AreasS-11Standard Precast manholeS-12Shallow Precast ManholeS-13Drop Manhole Type AS-14Drop Manhole Type BS-15Alternate Drop Manhole Precast Base and CollarsS-16Terminal ManholeS-17Standard Heavy Traffic Manhole Frame and CoverS-18Standard Watertight Frame and CoverS-19Concrete collar for Manhole Frame and CoverS-20Adjustment Grade RingS-21Standard Manhole StepsS-22Flexible Pipe to Manhole ConnectionS-23Waterstop Pipe to Manhole Connection for Steep GradesS-24Air Release and Vacuum Valve in ManholeS-25New Manhole Over Existing PipeS-26Abandonment of Pipe at ManholeS-27Complete Manhole AbandonmentS-28Pressure Sewer Blocking DetailsS-29Low Pressure Sewer and House Connection Blocking Details for Caps and PlugsS-30Anchoring Pressure Sewers (Upper Vertical Bends)S-31Air Test Requirements 6" and 8" Sewers with 4" LateralsS-32Air Test Requirements 10" and 12" Sewers with 4" LateralsS-33Air Test Requirements 15" and 18" Sewers with 4" LateralsS-34Air Test Requirements 21" and 24" Sewers with 4" LateralsS-35Air Test Requirements 4" through 24" Sewers without LateralsS-36Concrete Anchor (When Pipe Slopes Exceed 20)S-37Trench Erosion Check (For use in granular soils)