© 2018 Peace of Mind Home Inspections Inc. 3/14/2018 2:00PM Top Agent Real Estate Company Michael Moradian
47

Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

Jun 07, 2019

Download

Documents

ngocong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Peace of Mind Home Inspections Inc.

3/14/2018 2:00PM

Top Agent Real Estate Company

Michael Moradian

Page 2: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018

Page 3: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 3 of 47

Table of Contents

TABLE OF CONTENTS 3

REPORT OVERVIEW 4

SUMMARY 5

STRUCTURAL 6

ROOFING 8

EXTERIOR 11

ELECTRICAL 15

HEATING/COOLING 18

INSULATION / VENTILATION 20

PLUMBING 22

INTERIOR 26

APPLIANCES 30

FIREPLACES / WOOD STOVES 32

MAINTENANCE ADVICE 34

STANDARDS OF PRACTICE 36

Page 4: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 4 of 47

Report Overview THE HOUSE IN PERSPECTIVE

Date of Construction: 2007 Style: Single-Family Residence, Two Stories Main Entrance Faces: South State of Occupancy: Occupied, Fully Furnished Weather Conditions: Rain, 60-65 F Recent Rain: Yes Ground cover: Raining

CONVENTIONS USED IN THIS REPORT

For your convenience, the following conventions have been used in this report. Major Concern: a system or component which is considered significantly deficient or is unsafe. Significant deficiencies need to be corrected and, except for some safety items, are likely to involve significant expense.

Safety Issue: denotes a condition that is unsafe and in need of prompt attention.

Repair: denotes a system or component which is missing or which needs corrective action to assure proper and reliable function.

Improve: denotes improvements which are recommended but not required.

Limitations: denotes items that had limitation in our observation

Monitor: denotes a system or component needing further investigation and/or monitoring in order to determine if repairs are necessary.

Note: denotes items that we want to make you aware that are not repair related.

Deferred Cost: denotes items that have reached or are reaching their normal life expectancy or show indications that they may require repair or replacement anytime during the next five (5) years.

Please note that those observations listed under “Discretionary Improvements” are not essential repairs, but represent logical long term improvements.

CONFIDENTIALITY AGREEMENT

This confidential report is prepared exclusively for Sample Report. The usage of this report by any other interested party without written consent of Peace of Mind Home Inspections is prohibited and deemed unlawful.

THE SCOPE OF THE INSPECTION

All components designated for inspection in the Peace of Mind Standards of Practice are inspected, except as may be noted within this report. It is the goal of the inspection to put a home buyer in a better position to make a buying decision. Not all improvements will be identified during this inspection. Unexpected repairs should still be anticipated as this is a general representation of the condition of the house. The inspection should not be considered a guarantee or warranty of any kind. This inspection is visual only. A representative sample of building components are viewed in areas that are accessible at the time of the inspection. No destructive testing or dismantling of building components is performed. The pictures are a general representation to assist in understanding the items that are noted. Other items may also need repair but may not be shown in the picture

Page 5: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 5 of 47

Summary

DESCRIPTION OF SUMMARY

The following is a synopsis of the potentially significant safety, major repair, and repair items that should be budgeted for over the short term. Other significant improvements outside the scope of this inspection may also be necessary. Please review the entire report for additional findings and recommendations that may not show up in the summary section and to understand the full scope of the inspection report.

SAFETY, MAJOR REPAIR, AND REPAIR RECOMMENDATIONS SUMMARY

ROOFING Repair: The gutter(s) require cleaning to avoid spilling roof runoff around the building – a potential source of water

entry or water damage.

EXTERIOR Repair: The eave(s), (fascia, sheathing and/or rafters) at the northwest corner of the house shows evidence wood

deterioration. The client should refer to the wood destroying pest and organism report (termite report) for all locations of wood deteriorations. You may wish to have a licensed roofing contractor further evaluate.

Repair, Safety Issue: The overhead garage door requires adjustment for easy and safe operation.

ELECTRICAL Safety Issue: Ground fault circuit interrupter (GFCI) outlet(s) in the garage did not respond correctly to testing during

the inspection. This receptacle should be replaced.

PLUMBING Repair: The shower faucet handle(s) at the 2nd floor hallway bathroom is/are loose.

INTERIOR Repair: The window spring(s) (the spring that holds up the window(s)) at various locations is/are damaged or not

functioning properly.

Page 6: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 6 of 47

Structural DESCRIPTION OF STRUCTURAL

Foundation: Poured Concrete

Crawl Space / Foundation: Slab on Grade

Wall Structure: Wood Frame

Roof / Ceiling Structure: Waferboard Sheathing Trusses

Attic Inspected: From Inside Attic

STRUCTURAL OBSERVATIONS

COMMENTS The construction of the house is of satisfactory quality with the building construction and with the quality of materials employed.

Page 7: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 7 of 47

LIMITATIONS OF STRUCTURAL INSPECTION

As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions: Structural components concealed behind finished surfaces could not be inspected.

Only representative samplings of visible structural components were inspected.

Furniture and/or storage restricted access to some structural components.

Engineering or architectural services such as calculation of structural capacities, adequacy, or integrity are not part of a home inspection.

Please also refer to the Inspection Agreement and Standards of Practice for a detailed explanation of the scope of this inspection.

Page 8: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 8 of 47

Roofing DESCRIPTION OF ROOFING

Method of Inspection: Viewed from Ground Viewed from Ladder at Eave

Roof Pitch: 5/12

Number of Roof Layers: One Layer

Sloped Roof Covering: Concrete Tile Estimated Life Remaining: 39 Yr(s) Estimated Age: 11 Yr(s)

Roof Flashings: Metal

Skylights: None

Chimneys: Wood Frame Metal Flue

Roof Drainage System: Discharge Above and Below Grade Galvanized Steel

ROOFING OBSERVATIONS

COMMENTS The roof coverings appear to be generally in satisfactory condition.

Page 9: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 9 of 47

RECOMMENDATIONS/OBSERVATIONS

Sloped Roofing Limitation: Portions of the roof were viewed from the ground and some sections of the roof could not be viewed.

Gutters, Downspouts and Drains Monitor: The downspout(s) discharge water to an underground drainage system. Debris and sediment can collect at the

low areas of the drainage system, eventually clogging the drain, which can be worse than having no drains at all. If drains are suspected of being clogged they should be disconnected and cleaned out to allow adequate flow.

Improve: The gutter(s) was/were noted to be leaking.

Repair: The gutter(s) require cleaning to avoid spilling roof runoff around the building – a potential source of water entry or water damage.

Page 10: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 10 of 47

LIMITATIONS OF ROOFING INSPECTION

As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions: The entire underside of the roof sheathing was not inspected for evidence of leaks.

Evidence of prior leaks may be disguised by interior finishes.

Estimates of remaining roof life are approximations only and do not preclude the possibility of leakage. Leakage can develop at any time and may depend on rain intensity, wind direction, ice buildup, and other factors.

Antennae, chimney/flue interiors which are not readily accessible are not inspected and could require repair.

Roof inspection may be limited by access, condition, weather, or other safety concerns.

Please also refer to the Inspection Agreement and Standards of Practice for a detailed explanation of the scope of this inspection.

Page 11: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 11 of 47

Exterior DESCRIPTION OF EXTERIOR

Wall Covering: Asphalt Shingle Stucco

Eaves, Soffits, and Fascias: Wood Open Rafters

Exterior Doors: Sliding Glass Fiberglass Composite Solid Wood

Window Frames: Vinyl

Garage: Drywall Finished Attached Garage

Overhead Garage Door(s): Steel/Aluminum Automatic Opener Installed

Grading and Drainage: Level Grade

Walkways, Driveways & Garage: Concrete

Fencing: Wood

EXTERIOR OBSERVATIONS

COMMENTS The exterior of the home shows normal wear and tear for a home of this age.

Page 12: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 12 of 47

RECOMMENDATIONS/OBSERVATIONS

Exterior Eaves Repair: The eave(s), (fascia, sheathing and/or rafters) at the northwest corner of the house shows evidence wood

deterioration. The client should refer to the wood destroying pest and organism report (termite report) for all locations of wood deteriorations. You may wish to have a licensed roofing contractor further evaluate.

Exterior Man Doors Improve: The hardware for the sliding glass door(s) is little loose.

Exterior Walls Improve: Penetration through the exterior siding were observed and may allow water intrusion and possible damage.

Page 13: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 13 of 47

Improve: Minor flaws and/or chips in the stucco were observed on the exterior walls of the house at the west side of the garage.

Improve, Monitor: Stucco crack(s) was/were observed on the exterior walls of the house. This implies that structural movement has occurred.

Exterior Windows Improve: Window screen(s) at the 1st floor bedroom is/are damaged or missing. The client may choose to repair or

replace the window screen(s).

Page 14: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 14 of 47

Fence Improve: The fencing at various locations is damaged or missing and needs repairs.

Garage Door(s) Repair, Safety Issue: The overhead garage door requires adjustment for easy and safe operation.

LIMITATIONS OF EXTERIOR INSPECTION

As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions: A representative sample of exterior components was inspected rather than every occurrence of components.

The inspection does not include an assessment of geological, geotechnical, or hydrological conditions, or environmental hazards.

Screening, shutters, awnings, or similar seasonal accessories, fences, recreational facilities, outbuildings, seawalls, break-walls, docks, erosion control and earth stabilization measures are not inspected unless specifically agreed-upon and documented in this report.

Please also refer to the Inspection Agreement and Standards of Practice for a detailed explanation of the scope of this inspection.

Page 15: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 15 of 47

Electrical DESCRIPTION OF ELECTRICAL

Electrical Service: 120/240 Volt Main Service Service Drop Underground

Service Equip / Main Disconnect: Main Breaker Rating 200 Amps Panel Rating: 200 Amp Breakers

Service Grounding: Copper Water Pipe Connection Ufer Ground Gas Pipe Connection

Distribution Wiring: Unknown

Wiring Method: Non-Metallic (Romex)

Outlets / Switches: Grounded

Ground Fault Circuit Interrupter: Bathroom(s) Exterior Garage Kitchen

Arc-fault Circuit Interrupter: Main Electrical Panel

Smoke Detector(s): 1st Floor Hallway 2nd Floor Hallway Bedrooms

Carbon Monoxide Detector(s): 1st Floor Hallway 2nd Floor Hallway

ELECTRICAL OBSERVATIONS

COMMENTS Carbon Monoxide detector(s) were present and responded to testing. Smoke detector(s) were present and responded to testing. The size of the electrical service is sufficient for typical single-family needs. All outlets and light fixtures that were tested operated satisfactorily. The outlets that were tested appear to be appropriately grounded. Ground fault circuit interrupter (GFCI) devices have been provided in some areas of the home. These devices are extremely valuable, as they offer an extra level of shock protection.

Page 16: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 16 of 47

RECOMMENDATIONS/OBSERVATIONS

Electrical Main Disconnect Location The main disconnect is located at the west side of the garage. In case of an emergency the electricity can be turned off to

the entire home by turning off the main disconnect breaker, if your service does not have a main disconnect then all of the breakers need to be turned off.

Main Panel Limitation: The main electrical panel was not inspected for proper wiring and safety due to rain.

GFCI Outlets Safety Issue: Ground fault circuit interrupter (GFCI) outlet(s) in the garage did not respond correctly to testing during

the inspection. This receptacle should be replaced.

Ground fault circuit interrupter (GFCI) devices offer protection from shock or electrocution. GFCI devices are typically used at exterior, garage, bathroom, kitchen and whirlpool outlets. If an outlet which is connected to the GFCI device becomes inoperative the GFCI devices should be located and reset by depressing the reset button. These GFCI devices are located at the 1st floor bathroom, kitchen, garage and exterior.

Page 17: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 17 of 47

LIMITATIONS OF ELECTRICAL INSPECTION

As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions: Electrical components concealed behind finished surfaces are not inspected.

Only a representative sampling of outlets and light fixtures were tested.

Furniture and/or storage restricted access to some electrical components which may not be inspected.

The inspection does not include remote control devices, alarm systems and components, low voltage wiring, systems, and components, ancillary wiring, systems, and other components which are not part of the primary electrical power distribution system.

Please also refer to the Inspection Agreement and Standards of Practice for a detailed explanation of the scope of this inspection.

Page 18: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 18 of 47

Heating/Cooling DESCRIPTION OF HEATING/COOLING

Condenser/Heat Pump 1: Located: at the northeast corner of the house Independent Air Conditioning

System Electric 240 Volt Power Supply Manufacturer: York Age: 11 Yrs

Estimated Serial #: W0L6051790 Installed Amps: 30 Max Amps Rating: 30

Furnace/Air Handler 1: Located: in the 2nd floor attic Exhaust Metal-Multi Wall Forced Air Furnace

Fuel Source: Natural Gas Age: 11 Yrs Estimated Manufacturer: York Serial #: W0H6852961

Distribution Methods: Ductwork

HEATING/COOLING OBSERVATIONS

COMMENTS The HVAC Unit(s) warranty typically is/are 15-20 years. With regular maintenance from a HVAC technician you may be able to lengthen the lifespan of the unit(s).

Page 19: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 19 of 47

RECOMMENDATIONS/OBSERVATIONS

Air Conditioning Note: Upon testing the air conditioning system(s) the temperature drop difference between the return vent(s) and

register(s) was/were 15+ degrees, which is in the normal range an AC system should operate.

LIMITATIONS OF HEATING/COOLING INSPECTION

As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions: The adequacy of heat supply or distribution balance is not inspected.

The interior of flues or chimneys which are not readily accessible are not inspected.

The furnace heat exchanger, humidifier, or dehumidifier, and electronic air filters are not inspected.

Solar space heating equipment/systems are not inspected.

The cooling supply adequacy or distribution balances are not inspected.

Window mounted air conditioning units are not inspected.

Please also refer to the Inspection Agreement and Standards of Practice for a detailed explanation of the scope of this inspection.

Page 20: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 20 of 47

Insulation / Ventilation DESCRIPTION OF INSULATION / VENTILATION

Attic Inspected: From Inside Attic

Attic Insulation: Loose Blown Fiberglass

Attic Insulation R-Value: Estimated Attic R-Value 38

Attic Ventilation: Soffit Vents Gable Vents

Exhaust Fan / Vent Locations: Laundry Bathroom

INSULATION / VENTILATION OBSERVATIONS

COMMENTS Attic seems to have adequate ventilation which should reduce heat and moisture buildup. Typically, you are trying to achieve Attic R-Value 30 to 38 and a crawlspace R-Value 13. The approximate R-Value per inch for Fiberglass Batts is (3.7), Fiberglass Blown-in is (3.2), and Cellulose Blown-in is (3.65). If you multiply your insulation depth x per inch R-Value you get your total R-Value (i.e. 12 inches of Fiberglass Batts; 12 x 3.7 = Approximately R38). The attic insulation levels were noted to be at a satisfactory level and condition. This will improve the comfort level and reduce energy costs.

Page 21: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 21 of 47

RECOMMENDATIONS/OBSERVATIONS

Insulation Improve: Insulation in the attic that has been compacted down by people walking around in the attic should be evened

out to get the proper R-rating of the insulation.

LIMITATIONS OF INSULATION / VENTILATION INSPECTION

As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions: Insulation/ventilation type and levels in concealed areas are not inspected. Insulation and vapor barriers are not

disturbed and no destructive tests (such as cutting openings in walls to look for insulation) are performed.

Potentially hazardous materials such as Asbestos and Urea Formaldehyde Foam Insulation (UFFI) cannot be positively identified without a detailed inspection and laboratory analysis. This is beyond the scope of the inspection.

An analysis of indoor air quality is not part of our inspection unless explicitly contracted-for and discussed in this or a separate report.

Any estimates of insulation R values or depths are rough average values.

Please also refer to the Inspection Agreement and Standards of Practice for a detailed explanation of the scope of this inspection.

Page 22: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 22 of 47

Plumbing DESCRIPTION OF PLUMBING

Water Supply Source: Public Water Supply

Service Pipe to House: Copper

Interior Supply Piping: PEX Copper

Waste System: Public Sewer System

Waste Piping: ABS

Fuel Source: Natural Gas

Water Heater 1: Located: in the garage Manufacturer: State Serial Number: H06J058414

Age: 11 Estimated Yrs Gallons: 50 Exhaust Metal-Multi Wall Fuel Source: Natural Gas

PLUMBING OBSERVATIONS

COMMENTS In all the plumbing system was noted to be in satisfactory condition. The water heater(s) warranty is/are typically 7 to 12 years. With regular maintenance, you may be able to lengthen the lifespan of the unit(s). Predicting the frequency or time frame for repairs on any mechanical device is virtually impossible. The water heater was noted to be working and produced hot water. The water pressure supplied to the fixtures is reasonably good. A typical drop in flow was experienced when two fixtures were operated simultaneously.

Page 23: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 23 of 47

RECOMMENDATIONS/OBSERVATIONS

Locations The water heater is located in the garage. The temperature control is on the front of the unit towards the bottom.

The main gas shutoff is located at the west side of the garage. In case of an emergency the valve can be used to turn off the gas to the property. It is recommended that the client purchase an inexpensive gas shutoff wrench and store it near or at the gas main for easy and quick access in an emergency.

The main water shutoff is/was at the southeast corner of the house. In case of an emergency the valve can be used to turn off water to the property.

Page 24: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 24 of 47

Hose Bibs Improve: It is recommended that an anti-siphon device be added to the hose bib(s).

Shower Repair: The shower faucet handle(s) at the 2nd floor hallway bathroom is/are loose.

Supply Plumbing Improve: Supply pipe(s) and/or hose bib(s) is/are not insulated and should be to prevent them from freezing or

accidentally bursting in extreme cold temperatures.

Page 25: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 25 of 47

Toilets Monitor: Corrosion on the exterior toilet supply valve was observed at various locations.

LIMITATIONS OF PLUMBING INSPECTION

As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions: Portions of the plumbing system concealed by finishes and/or storage (below sinks, etc.), below the structure, or beneath

the ground surface are not inspected.

Water quantity and water quality are not tested unless explicitly contracted-for and discussed in this or a separate report.

Clothes washing machine connections are not inspected.

Interiors of flues or chimneys which are not readily accessible are not inspected.

Water conditioning systems, solar water heaters, fire and lawn sprinkler systems, and private waste disposal systems are not inspected unless explicitly contracted-for and discussed in this or a separate report.

An inspection of the lawn sprinkler system is outside the scope of this inspection.

Please also refer to the Inspection Agreement and Standards of Practice for a detailed explanation of the scope of this inspection.

Page 26: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 26 of 47

Interior DESCRIPTION OF INTERIOR

Wall/Ceiling Materials: Drywall

Floor Surfaces: Tile Carpet

Window Type(s) / Glazing: Double Glazed Fixed Pane Sliders Double / Single Hung

Doors: Wood-Hollow Core

Countertops: Cultured Marble Granite

INTERIOR OBSERVATIONS

COMMENTS The majority of the doors are good condition and function properly. The floors of the home are relatively level and walls are relatively plumb. On the whole, the interior finishes of the home are in average condition. Typical flaws were observed in some areas. The majority of the windows are average quality units.

Page 27: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 27 of 47

RECOMMENDATIONS/OBSERVATIONS

Wall / Ceiling Finishes Notes: The toilet paper holder(s), hanger rod, and/or towel rack(s) at the 1st floor bathroom is/are damaged or missing.

Floors Improve: The flooring at the front entry shows signs of wear.

Monitor, Improve: The tile floor(s) at the front entry and family room is/are cracked and should be monitored for further movement. This is typical for tile on slab on grade foundation (Concrete floors), caused by the concrete shrinking or settling.

Page 28: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 28 of 47

Windows Repair: The window spring(s) (the spring that holds up the window(s)) at various locations is/are damaged or not

functioning properly.

Improve: The window(s) did not slide smoothly and should be improved to operate freely.

Doors Improve: The guide at the bottom of door(s) is/are loose or damaged.

Page 29: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 29 of 47

Improve: Missing or damaged door stop(s) should be installed or replaced to prevent damage to walls.

LIMITATIONS OF INTERIOR INSPECTION

As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions Floor coverings, furniture, storage, appliances and/or wall hangings are not moved to permit inspection and may block

defects.

Carpeting, window treatments, central vacuum systems, appliances, recreational facilities, paint, wallpaper, and other finish treatments are not inspected.

Please also refer to the Inspection Agreement and Standards of Practice for a detailed explanation of the scope of this inspection.

Page 30: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 30 of 47

Appliances DESCRIPTION OF APPLIANCES

Laundry Facility: 240 Volt Circuit for Dryer, Gas Piping for Dryer, Dryer Vented to Building Exterior, 120 Volt Circuit for Washer, Hot and Cold Water Supply for Washer, Waste Standpipe for Washer

Appliances Tested: Microwave Oven Cooktop Oven Garbage Disposal Dishwasher

APPLIANCES OBSERVATIONS

COMMENTS The appliances were noted to operate when tested and were in satisfactory condition.

Page 31: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 31 of 47

RECOMMENDATIONS/OBSERVATIONS

Refrigerator Limitation: The refrigerator(s) was off or unplugged and not tested.

LIMITATIONS OF APPLIANCES INSPECTION

As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions Thermostats, timers and other specialized features and controls are not tested.

The temperature calibration, functionality of timers, effectiveness, efficiency and overall performance of appliances is outside the scope of this inspection.

Please also refer to the Inspection Agreement and Standards of Practice for a detailed explanation of the scope of this inspection.

Page 32: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 32 of 47

Fireplaces / Wood Stoves DESCRIPTION OF FIREPLACES / WOOD STOVES

Fireplaces/Stove/Chimney 1: Located in the family room Cosmetic/Non-Functional Gas Wood Framed Chimney - Metal Flue

FIREPLACES / WOOD STOVES OBSERVATIONS

COMMENTS On the whole, the fireplace and its components were found to be in satisfactory condition. Typical flaws were observed in some areas.

Page 33: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 33 of 47

LIMITATIONS OF FIREPLACES / WOOD STOVES INSPECTION

As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions The interiors of flues or chimneys are not inspected. It is recommended the client have a chimney specialist to further

evaluate and certify the chimney.

Fire screens, fireplace doors, appliance gaskets and seals, automatic fuel feed devices, mantles and fireplace surrounds, combustion make-up air devices, and heat distribution assists (gravity or fan-assisted) are not inspected.

The inspection does not involve igniting or extinguishing fires nor the determination of draft.

Fireplace inserts, stoves, or firebox contents are not moved.

Please also refer to the Inspection Agreement and Standards of Practice for a detailed explanation of the scope of this inspection.

Page 34: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 34 of 47

Maintenance Advice

PREVENTION IS THE BEST APPROACH

Although we’ve heard it many times, nothing could be truer than the old cliché “an ounce of prevention is worth a pound of cure.” Preventative maintenance is the best way to keep your house in great shape. It also reduces the risk of unexpected repairs and improves the odds of selling your house at fair market value, when the time comes.

Please feel free to contact our office should you have any questions regarding the operation or maintenance of your home. Enjoy your home!

UPON TAKING OWNERSHIP

After taking possession of a new home, there are some maintenance and safety issues that should be addressed immediately. The following checklist should help you undertake these improvements:

Change the locks on all exterior entrances, for improved security.

Check that all windows and doors are secure. Improve window hardware as necessary. Security rods can be added to sliding windows and doors. Consideration could also be given to a security system.

Install smoke detectors on each level of the home. Ensure that there is a smoke detector outside all sleeping areas. Replace batteries on any existing smoke detectors and test them. Make a note to replace batteries again in one year.

Create a plan of action in the event of a fire in your home. Ensure that there is an operable window or door in every room of the house. Consult with your local fire department regarding fire safety issues and what to do in the event of fire.

Examine driveways and walkways for trip hazards. Undertake repairs where necessary.

Examine the interior of the home for trip hazards. Loose or torn carpeting and flooring should be repaired.

Undertake improvements to all stairways, decks, porches and landings where there is a risk of falling or stumbling.

Review your home inspection report for any items that require immediate improvement or further investigation. Address these areas as required.

Install rain caps and vermin screens on all chimney flues, as necessary.

Investigate the location of the main shut-offs for the plumbing, heating and electrical systems. If you attended the home inspection, these items would have been pointed out to you.

REGULAR MAINTENANCE

EVERY MONTH

Check that fire extinguisher(s) are fully charged. Re-charge if necessary.

Examine heating/cooling air filters and replace or clean as necessary.

Inspect and clean humidifiers and electronic air cleaners.

If the house has hot water heating, bleed radiator valves.

Clean gutters and downspouts. Ensure that downspouts are secure, and that the discharge of the downspouts is appropriate. Remove debris from window wells.

Carefully inspect the condition of shower enclosures. Repair or replace deteriorated grout and caulk. Ensure that water is not escaping the enclosure during showering. Check below all plumbing fixtures for evidence of leakage.

Repair or replace leaking faucets or shower heads.

Secure loose toilets, or repair flush mechanisms that become troublesome.

SPRING AND FALL

Examine the roof for evidence of damage to roof coverings, flashings and chimneys.

Page 35: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 35 of 47

Look in the attic (if accessible) to ensure that roof vents are not obstructed. Check for evidence of leakage, condensation or vermin activity. Level out insulation if needed.

Trim back tree branches and shrubs to ensure that they are not in contact with the house.

Inspect the exterior walls and foundation for evidence of damage, cracking or movement. Watch for bird nests or other vermin or insect activity.

Survey the basement and/or crawl space walls for evidence of moisture seepage.

Look at overhead wires coming to the house. They should be secure and clear of trees or other obstructions.

Ensure that the grade of the land around the house encourages water to flow away from the foundation.

Inspect all driveways, walkways, decks, porches, and landscape components for evidence of deterioration, movement or safety hazards.

Clean windows and test their operation. Improve caulking and weather-stripping as necessary. Watch for evidence of rot in wood window frames. Paint and repair window sills and frames as necessary.

Test all ground fault circuit interrupter (GFCI) devices, as identified in the inspection report.

Shut off isolating valves for exterior hose bibs in the fall, if below freezing temperatures are anticipated.

Test the Temperature and Pressure Relief (TPR) Valve on water heaters.

Inspect for evidence of wood boring insect activity. Eliminate any wood/soil contact around the perimeter of the home.

Test the overhead garage door opener, to ensure that the auto-reverse mechanism is responding properly. Clean and lubricate hinges, rollers and tracks on overhead doors.

Replace or clean exhaust hood filters.

Clean, inspect and/or service all appliances as per the manufacturer’s recommendations.

ANNUALLY

Replace smoke detector batteries.

Have the heating, cooling and water heater systems cleaned and serviced.

Have chimneys inspected and cleaned. Ensure that rain caps and vermin screens are secure.

Examine the electrical panels, wiring and electrical components for evidence of overheating. Ensure that all components are secure. Flip the breakers on and off to ensure that they are not sticky.

If the house utilizes a well, check and service the pump and holding tank. Have the water quality tested. If the property has a septic system, have the tank inspected (and pumped as needed).

If your home is in an area prone to wood destroying insects (termites, carpenter ants, etc.), have the home inspected by a licensed specialist. Preventative treatments may be recommended in some cases.

Page 36: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 36 of 47

International

Standards of Practice for Performing a General

Home Inspection

Table of Contents 1. Definitions and Scope 2. Limitations, Exceptions & Exclusions 3. Standards of Practice

3.1. Roof 3.2. Exterior 3.3. Basement, Foundation, Crawlspace & Structure 3.4. Heating 3.5. Cooling 3.6. Plumbing 3.7. Electrical 3.8. Fireplace 3.9. Attic & Insulation 3.10. Doors, Windows & Interior

4. Glossary of Terms

Last revised June 2013

1. Definitions and Scope

1.1. A general home inspection is a non-invasive, visual examination of the accessible areas of a residential property (as delineated below), performed for a fee, which is designed to identify defects within specific systems and components defined by these Standards that are both observed and deemed material by the inspector. The scope of work may be modified by the Client and Inspector prior to the inspection process.

I. The general home inspection is based on the observations made on the date of the inspection, and not a prediction of future conditions.

II. The general home inspection will not reveal every issue that exists or ever could exist, but only those material defects observed on the date of the inspection.

1.2. A material defect is a specific issue with a system or component of a residential property that may have a significant, adverse impact on the value of the property, or that poses an unreasonable risk to people. The fact that a system or component is near, at, or beyond the end of its normal, useful life is not, in itself, a material defect.

1.3. A general home inspection report shall identify, in written format, defects within specific systems and components defined by these Standards that are both observed and deemed material by the inspector. Inspection reports may include additional comments and recommendations.

Page 37: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 37 of 47

2. Limitations, Exceptions & Exclusions

2.1. Limitations:

I. An inspection is not technically exhaustive. II. An inspection will not identify concealed or latent defects.

III. An inspection will not deal with aesthetic concerns or what could be deemed matters of taste, cosmetic defects, etc.

IV. An inspection will not determine the suitability of the property for any use. V. An inspection does not determine the market value of the property or its marketability. VI. An inspection does not determine the insurability of the property.

VII. An inspection does not determine the advisability or inadvisability of the purchase of the inspected property.

VIII. An inspection does not determine the life expectancy of the property or any components or systems therein.

IX. An inspection does not include items not permanently installed. X. This Standards of Practice applies to properties with four or fewer residential units and their attached

garages and carports.

2.2. Exclusions:

I. The inspector is not required to determine:

A. property boundary lines or encroachments. B. the condition of any component or system that is not readily accessible. C. the service life expectancy of any component or system. D. the size, capacity, BTU, performance or efficiency of any component or system. E. the cause or reason of any condition. F. the cause for the need of correction, repair or replacement of any system or component. G. future conditions. H. compliance with codes or regulations. I. the presence of evidence of rodents, birds, animals, insects, or other pests. J. the presence of mold, mildew or fungus. K. the presence of airborne hazards, including radon. L. the air quality. M. the existence of environmental hazards, including lead paint, asbestos or toxic drywall. N. the existence of electromagnetic fields. O. any hazardous waste conditions. P. any manufacturers' recalls or conformance with manufacturer installation, or any information included for

consumer protection purposes. Q. acoustical properties. R. correction, replacement or repair cost estimates. S. estimates of the cost to operate any given system.

II. The inspector is not required to operate:

A. any system that is shut down. B. any system that does not function properly. C. or evaluate low-voltage electrical systems, such as, but not limited to:

1. phone lines; 2. cable lines; 3. satellite dishes; 4. antennae; 5. lights; or 6. remote controls.

Page 38: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 38 of 47

D. any system that does not turn on with the use of normal operating controls. E. any shut-off valves or manual stop valves. F. any electrical disconnect or over-current protection devices. G. any alarm systems. H. moisture meters, gas detectors or similar equipment.

III. The inspector is not required to:

A. move any personal items or other obstructions, such as, but not limited to: throw rugs, carpeting, wall coverings, furniture, ceiling tiles, window coverings, equipment, plants, ice, debris, snow, water, dirt, pets, or anything else that might restrict the visual inspection.

B. dismantle, open or uncover any system or component. C. enter or access any area that may, in the inspector's opinion, be unsafe. D. enter crawlspaces or other areas that may be unsafe or not readily accessible. E. inspect underground items, such as, but not limited to: lawn-irrigation systems, or underground storage

tanks (or indications of their presence), whether abandoned or actively used. F. do anything that may, in the inspector's opinion, be unsafe or dangerous to him/herself or others, or

damage property, such as, but not limited to: walking on roof surfaces, climbing ladders, entering attic spaces, or negotiating with pets.

G. inspect decorative items. H. inspect common elements or areas in multi-unit housing. I. inspect intercoms, speaker systems or security systems. J. offer guarantees or warranties. K. offer or perform any engineering services. L. offer or perform any trade or professional service other than general home inspection. M. research the history of the property, or report on its potential for alteration, modification, extendibility or

suitability for a specific or proposed use for occupancy. N. determine the age of construction or installation of any system, structure or component of a building, or

differentiate between original construction and subsequent additions, improvements, renovations or replacements.

O. determine the insurability of a property. P. perform or offer Phase 1 or environmental audits. Q. inspect any system or component that is not included in these Standards.

3. Standards of Practice

3.1. Roof

I. The inspector shall inspect from ground level or the eaves:

A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs.

II. The inspector shall describe:

A. the type of roof-covering materials.

III. The inspector shall report as in need of correction:

A. observed indications of active roof leaks.

Page 39: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 39 of 47

IV. The inspector is not required to:

A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspector's opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

3.2. Exterior

I. The inspector shall inspect:

A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect

the structure due to moisture intrusion.

II. The inspector shall describe:

A. the type of exterior wall-covering materials.

III. The inspector shall report as in need of correction:

A. any improper spacing between intermediate balusters, spindles and rails.

IV. The inspector is not required to:

A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting.

B. inspect items that are not visible or readily accessible from the ground, including window and door flashing.

C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools.

Page 40: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 40 of 47

N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

3.3. Basement, Foundation, Crawlspace & Structure

I. The inspector shall inspect:

A. the foundation; B. the basement; C. the crawlspace; and D. structural components.

II. The inspector shall describe:

A. the type of foundation; and B. the location of the access to the under-floor space.

III. The inspector shall report as in need of correction:

A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-

square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion,

present a structural or safety concern.

IV. The inspector is not required to:

A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself.

B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing,

joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

3.4. Heating

I. The inspector shall inspect:

A. the heating system, using normal operating controls.

II. The inspector shall describe:

A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method.

III. The inspector shall report as in need of correction:

A. any heating system that did not operate; and B. if the heating system was deemed inaccessible.

Page 41: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 41 of 47

IV. The inspector is not required to:

A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems.

B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply

adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other

circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.

3.5. Cooling

I. The inspector shall inspect:

A. the cooling system, using normal operating controls.

II. The inspector shall describe:

A. the location of the thermostat for the cooling system; and B. the cooling method.

III. The inspector shall report as in need of correction:

A. any cooling system that did not operate; and B. if the cooling system was deemed inaccessible.

IV. The inspector is not required to:

A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system.

B. inspect portable window units, through-wall units, or electronic air filters. C. operate equipment or systems if the exterior temperature is below 65° Fahrenheit, or when other

circumstances are not conducive to safe operation or may damage the equipment. D. inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks. E. examine electrical current, coolant fluids or gases, or coolant leakage.

3.6. Plumbing

I. The inspector shall inspect:

A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-

relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats.

Page 42: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 42 of 47

II. The inspector shall describe:

A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled.

III. The inspector shall report as in need of correction:

A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that

did not operate.

IV. The inspector is not required to:

A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well

pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of

any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, back-flow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves,

control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar

water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.

3.7. Electrical

I. The inspector shall inspect:

A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses);

Page 43: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 43 of 47

I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed

and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs

using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors.

II. The inspector shall describe:

A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed.

III. The inspector shall report as in need of correction:

A. deficiencies in the integrity of the service-entrance conductors’ insulation, drip loop, and vertical clearances from grade and roofs;

B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place,

the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and

E. the absence of smoke detectors.

IV. The inspector is not required to:

A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures.

B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms. F. inspect, operate or test any security, fire or alarm systems or components, or other warning or signaling

systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any time-controlled

devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills,

photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

3.8. Fireplace

I. The inspector shall inspect:

A. readily accessible and visible portions of the fireplaces and chimneys; B. lintels above the fireplace openings; C. damper doors by opening and closing them, if readily accessible and manually operable; and D. cleanout doors and frames.

Page 44: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 44 of 47

II. The inspector shall describe:

A. the type of fireplace.

III. The inspector shall report as in need of correction:

A. evidence of joint separation, damage or deterioration of the hearth, hearth extension or chambers; B. manually operated dampers that did not open and close; C. the lack of a smoke detector in the same room as the fireplace; D. the lack of a carbon-monoxide detector in the same room as the fireplace; and E. cleanouts not made of metal, pre-cast cement, or other non-combustible material.

IV. The inspector is not required to:

A. inspect the flue or vent system. B. inspect the interior of chimneys or flues, fire doors or screens, seals or gaskets, or mantels. C. determine the need for a chimney sweep. D. operate gas fireplace inserts. E. light pilot flames. F. determine the appropriateness of any installation. G. inspect automatic fuel-fed devices. H. inspect combustion and/or make-up air devices. I. inspect heat-distribution assists, whether gravity-controlled or fan-assisted. J. ignite or extinguish fires. K. determine the adequacy of drafts or draft characteristics. L. move fireplace inserts, stoves or firebox contents. M. perform a smoke test. N. dismantle or remove any component. O. perform a National Fire Protection Association (NFPA)-style inspection. P. perform a Phase I fireplace and chimney inspection.

3.9. Attic, Insulation & Ventilation

I. The inspector shall inspect:

A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area.

II. The inspector shall describe:

A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure.

III. The inspector shall report as in need of correction:

A. the general absence of insulation or ventilation in unfinished spaces.

IV. The inspector is not required to:

A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard.

Page 45: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 45 of 47

B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.

3.10. Doors, Windows & Interior

I. The inspector shall inspect:

A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls.

II. The inspector shall describe:

A. a garage vehicle door as manually-operated or installed with a garage door opener.

III. The inspector shall report as in need of correction:

A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings;

B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals.

IV. The inspector is not required to:

A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed

floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a

garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior,

including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations

or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens.

Page 46: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 46 of 47

P. operate or examine any sauna, steam-generating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices.

Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

4. Glossary of Terms

accessible: In the opinion of the inspector, can be approached or entered safely, without difficulty, fear or danger.

activate: To turn on, supply power, or enable systems, equipment or devices to become active by normal operating controls. Examples include turning on the gas or water supply valves to the fixtures and appliances, and activating electrical breakers or fuses.

adversely affect: To constitute, or potentially constitute, a negative or destructive impact. alarm system: Warning devices, installed or freestanding, including, but not limited to: carbon-monoxide

detectors, flue gas and other spillage detectors, security equipment, ejector pumps, and smoke alarms. appliance: A household device operated by the use of electricity or gas. Not included in this definition

are components covered under central heating, central cooling or plumbing. architectural service: Any practice involving the art and science of building design for construction of

any structure or grouping of structures, and the use of space within and surrounding the structures or the design, design development, preparation of construction contract documents, and administration of the construction contract.

component: A permanently installed or attached fixture, element or part of a system. condition: The visible and conspicuous state of being of an object. correction: Something that is substituted or proposed for what is incorrect, deficient, unsafe, or a defect. cosmetic defect: An irregularity or imperfection in something, which could be corrected, but is not

required. crawlspace: The area within the confines of the foundation and between the ground and the underside

of the lowest floor's structural component. decorative: Ornamental; not required for the operation of essential systems or components of a home. describe: To report in writing a system or component by its type or other observed characteristics in

order to distinguish it from other components used for the same purpose. determine: To arrive at an opinion or conclusion pursuant to examination. dismantle: To open, take apart or remove any component, device or piece that would not typically be

opened, taken apart or removed by an ordinary occupant. engineering service: Any professional service or creative work requiring engineering education, training

and experience, and the application of special knowledge of the mathematical, physical and engineering sciences to such professional service or creative work as consultation, investigation, evaluation, planning, design and supervision of construction for the purpose of assuring compliance with the specifications and design, in conjunction with structures, buildings, machines, equipment, works and/or processes.

enter: To go into an area to observe visible components. evaluate: To assess the systems, structures and/or components of a property. evidence: That which tends to prove or disprove something; something that makes plain or clear;

grounds for belief; proof. examine: To visually look (see inspect). foundation: The base upon which the structure or wall rests, usually masonry, concrete or stone, and

generally partially underground.

Page 47: Sample Home Inspection Report - peaceofmindhi.net · 3djh ri 6xppdu\ '(6&5,37,21 2) 6800$5< 7kh iroorzlqj lv d v\qrsvlv ri wkh srwhqwldoo\ vljqlilfdqw vdihw\ pdmru uhsdlu dqg uhsdlu

© 2018 Page 47 of 47

function: The action for which an item, component or system is specially fitted or used, or for which an item, component or system exists; to be in action or perform a task.

functional: Performing, or able to perform, a function. functional defect: A lack of or an abnormality in something that is necessary for normal and proper

functioning and operation, and, therefore, requires further evaluation and correction. general home inspection: The process by which an inspector visually examines the readily accessible

systems and components of a home and operates those systems and components utilizing this Standards of Practice as a guideline.

home inspection: See general home inspection. household appliances: Kitchen and laundry appliances, room air conditioners, and similar appliances. identify: To notice and report. indication: That which serves to point out, show, or make known the present existence of something

under certain conditions. inspect: To examine readily accessible systems and components safely, using normal operating

controls, and accessing readily accessible areas, in accordance with this Standards of Practice. inspected property: The readily accessible areas of the buildings, site, items, components and systems

included in the inspection. inspection report: A written communication (possibly including images) of any material

defects observed during the inspection. inspector: One who performs a real estate inspection. installed: Attached or connected such that the installed item requires a tool for removal. material defect: A specific issue with a system or component of a residential property that may have a

significant, adverse impact on the value of the property, or that poses an unreasonable risk to people. The fact that a system or component is near, at, or beyond the end of its normal, useful life is not, in itself, a material defect.

normal operating controls: Describes the method by which certain devices (such as thermostats) can be operated by ordinary occupants, as they require no specialized skill or knowledge.

observe: To visually notice. operate: To cause systems to function or turn on with normal operating controls. readily accessible: A system or component that, in the judgment of the inspector, is capable of being

safely observed without the removal of obstacles, detachment or disengagement of connecting or securing devices, or other unsafe or difficult procedures to gain access.

recreational facilities: Spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment and athletic facilities.

report (verb form): To express, communicate or provide information in writing; give a written account of. (See also inspection report.)

representative number: A number sufficient to serve as a typical or characteristic example of the item(s) inspected.

residential property: Four or fewer residential units. residential unit: A home; a single unit providing complete and independent living facilities for one or

more persons, including permanent provisions for living, sleeping, eating, cooking and sanitation. safety glazing: Tempered glass, laminated glass, or rigid plastic. shut down: Turned off, unplugged, inactive, not in service, not operational, etc. structural component: A component that supports non-variable forces or weights (dead loads) and

variable forces or weights (live loads). system: An assembly of various components which function as a whole. technically exhaustive: A comprehensive and detailed examination beyond the scope of a real estate

home inspection that would involve or include, but would not be limited to: dismantling, specialized knowledge or training, special equipment, measurements, calculations, testing, research, analysis, or other means.

unsafe: In the inspector's opinion, a condition of an area, system, component or procedure that is judged to be a significant risk of injury during normal, day-to-day use. The risk may be due to damage, deterioration, improper installation, or a change in accepted residential construction standards.

verify: To confirm or substantiate.