Safety (M-1)2

DANGEROUS BUILDING CONDITIONS

Collapse

Holes, weak floors and stairs

Suspended loads

Weakened steel roof members

Walls offset

Weakened roof trusses

Backdraft or flashover

Electrical shock hazards

Poor or obstructed visibility

Concrete spalling

Page 3: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)3

ELECTRICAL EMERGENCIESTypes

Contact with source or items in contact with source

Fire streams on energized equipment

Equipment used in a area where a ground gradient condition exists

Page 4: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)4

ELECTRICAL EMERGENCIESProcedures

Treat all wires as energizedDo not cut any wiresUse lock out / tag outWear full protective clothingAvoid raising ladders into power linesUse caution around downed wiresAvoid using water on electrical equipment

Page 5: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)5

PERSONNEL ACCOUNTABILITY SYSTEM

A system or means by which an incident commander can know what personnel are on an emergency scene and their assignments

Page 6: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)6

PERSONNEL ACCOUNTABILITY SYSTEM Reasons for Using

The IC can determine how to utilize personnel

The IC can quickly determine if firefighters are unaccounted for, possibly lost or trapped

Page 7: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)7

PERSONNEL ACCOUNTABILITY SYSTEM Components

List of all personnel operating at the incident

Be aware of the location and function of all companies at the incident

Constant contact of personnel by sight, head count, or communications

Used at every incident; all members participating

Page 8: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)8

PERSONNEL ACCOUNTABILITY SYSTEM “TAG” System

Personnel identification tag

Location or designated person

Before leaving fireground firefighters MUST collect their tag

Page 9: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)9

SAFETY EQUIPMENT

Noise barriers

Eye protection

Page 10: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)10

FIRE APPARATUS SAFETYRiding

Always sit in a seatAlways wear seat belt properlyNever try to don Protective Equipment

on the apparatus

Page 11: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)11

FIRE APPARATUS SAFETY Mounting and Dismounting

Never mount or dismount when the apparatus is moving

Use hand rails

Climb on the apparatus only at sites designated for climbing

Page 12: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)12

FIRE APPARATUS SAFETYWorking Around

Oncoming traffic

Water/oil on road

Lights used on scene

Hearing protection

Page 13: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)13

PORTABLE LIGHTING EQUIPMENT

Portable or mounted power generator

Power cordsConnectorsLamps Ground Fault Interrupter (GFI)

Page 14: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)14

GROUND FAULT INTERRUPTER (GFI)

A special electric circuit breaker used to prevent electrical shock

Circuit Breaker Receptacle

TEST

RESET

Page 15: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)15

PORTABLE LIGHTING EQUIPMENT Setup and Use

Set up the generator in an open area Never fill generator while it is running Use a ground fault interrupter Place cords so they won’t be a tripping hazard Never lay electrical cords in water Place lights so they won’t blind firefighters Place lights so they won’t be subject to water spray Start generator Use proper connectors and adapters Adjust lights as necessary

Page 16: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)16

CONTROLING UTILITIESShutting Off Natural Gas

Gas Meter

ON

OFF

Page 17: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)17

CONTROLING UTILITIESShutting Off LP Gas

Page 18: SAFETY State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.

Safety (M-1)18

CONTROLING UTILITIESShutting Off Electricity

Pull

Breaker