Top Banner
SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame
74
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

SAFETY MEETING

LEIGHTON LABORATORY

-Prepared by Archana Sudame

Page 2: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

OSHA REQUIREMENTS SAFETY TRAINING: You must receive adequate

training in working with hazardous chemicals. CHP: You must have access to your laboratory’s

Chemical Hygiene Plan. MSDS: Material Safety Data Sheets must be made

available to you. CHEMICAL INVENTORY: You must be informed

of hazardous chemicals present in your laboratory and of operations in which they are involved.

Page 3: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Injury and Illness Prevention Program (IIPP)

An Injury and Illness Prevention Program (IIPP) is a department's ongoing program for preventing work-related injuries and

illnesses and for creating a safe and healthful work environment

Refer to the Yellow Flip Chart of CHP

Page 4: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

IIPP specifies that-

• there will be initial training for new employees and when the IIPP was first established

• there will be training upon changes in the working environment

o with new job assignmentso whenever new substances, processes, procedures, or equipment are introduced

o whenever the employer is made aware of new or previously unrecognized hazards

Page 5: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Hazard Communication

Do you know:   • Where to find information concerning the hazards

of the chemicals present in your work area?•   When to use a laboratory chemical hood?• How to select appropriate eye protection?• What about gloves?• What to do in case you are involved in

a fire or chemical emergency?

Page 6: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

CHP• Cal/OSHA requires that all laboratories have a

written Chemical Hygiene Plan • It is on the yellow flip chart- that we all are required

to sign as soon as we complete a safety training• It contains recommended emergency procedures,

information on chemical hazards, a list of precautions to control exposure to hazards, phone numbers for emergency contacts, and other legally required information

Page 7: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

MSDS: Material Safety Data Sheets

1. Chemical product information: chemical name, trade name, chemical formula- manufacturers information/ address etc.

2. Hazardous ingredients: TLV (Threshold limit value) and PEL (Permissible exposure limit) will give you highest airborne concentration to which a person can safely be exposed to during a normal workday

3. Physical data: Color, appearance, boiling point vapor density etc.

Page 8: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

MSDS continued…

4. Fire and explosion data: Flash point- will tell you the temperature at which the chemical will release enough flammable vapor to ignite. This section also gives chemicals upper and lower flammability limits, special fire fighting procedures, any unusual fire or explosion hazards

5. Health hazard data: Gives acute/ chronic- health effects associated with overexposure to the chemical through inhalation, skin contact or ingestion. Includes emergency first aid procedures.

Page 9: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

MSDS continued…

8. Special protection information: lists special protection equipment/ clothing (respirator, mask, gloves, eye protection etc.)

7. Special precautions: discusses special precautions to be taken during handling and storage of the chemicals. Any other health and safety concerns not mentioned elsewhere on the MSDS

Search for MSDS at:

www.ucop.edu/riskmgt/ohp/msds.html

Page 10: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

MSDS continued…

6. Reactivity data: ability to react with and compatibility with other chemicals, Also mentions if it has tendency to explode or release toxic fumes.

7. Spill or leak procedure: Procedure to follow in case of accidental spill/ release. Gives protective equipment needed to contain or clean-up he spill. Information on proper disposal

Page 11: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Chemical Inventory

• Required by the office of Environmental, Health and safety (EH&S)

• Gives storage information/ location of chemicals- After using chemicals please put the chemicals back in their appropriate location

• Assists emergency responders Regina is working on it- so please bring any new

material/ chemical to her and Katie’s attention, please do not put it in storage cabinets/ shelf by yourself (Just put the date as soon as you receive the chemical)

Page 12: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Chemical storage

Safe storage of chemicals is a necessity in every laboratory in order to:

Provide for effective management of chemicals. Lessen the risk of fire. Prevent accidental mixing of incompatible

chemicals in emergencies. Minimize exposure to corrosive and toxic

chemicals.

Page 13: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Container labels

Labels on containers of purchased chemicals include:

The common name of the substance. An appropriate hazard warning.

Other label information may include procedures for:

Proper handling. Storage. Emergency response

Page 14: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

NFPA labels Chemical containers/ entrances to labs / chemical storage areas.

Blue indicates the health hazard.

Red indicates the fire hazard.

Yellow indicates the reactivity hazard.

White gives special information

such as water or oxidizer incompatibility.

Degree of the hazard is rated from 0 to 4

4 being the greatest hazard and 0 indicating no significant hazard.

Page 15: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Transporting Chemicals• Know the hazards associated i.e. read MSDS before

getting ready to transport chemical.• Wear protective clothing/ gloves etc.• Hazardous chemicals must be attended at all times

while being transported.• Use secondary containment like plastic tubs, bottle

carriers and liquid tight carts having lips in all four sides. Always use sturdy carts.

• Never put non-compatible chemicals in the same secondary containers.

• Do not use crowded walkways/ elevators while transporting hazardous chemicals.

Page 16: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Unwanted Hazardous Chemicals

EH&S picks up for:

• Reuse

• Recycling

• Disposal

Contact Bill Byrne for disposing chemicals / chemical-wastes

Page 17: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Drain Disposal

Do not dispose any hazardous material in the sinks-

• It interferes with the biological processes of sewage treatment

• Could be released to San Francisco Bay where they are toxic to aquatic organisms or where they accumulate in Bay sediment

Page 18: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Drain disposal of chemicals

• Create hazards of fire, explosion, or local air pollution or stench

• React with other chemicals to form hazardous gases, • Corrode lab and building plumbing, • Leak out of old pipes as liquid to pollute campus

grounds, • Escape from sewer pipes as air pollutants • Expose plumbers to contact or inhalation hazards.

Page 19: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Drain Disposal continued…

• In very small quantities certain water soluble chemicals and organics could be disposed into the sinks {e.g. Class A-solute only (100 gm/lab/day) and Class B-solute only (1 gm/lab/day)}

However, do not do so unless you read the document and check the list of Class A and Class B chemicals

http://www.ehs.berkeley.edu/pubs/guidelines/draindispgls.html

Page 20: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Exceptionally Hazardous Chemicals

1. Mercury

2. Ether

3. Nitric Acid and Nitrogen oxides

4. Phenol

5. Trichloroacetic acid

6. Perchloric acid and perchlorates

7. Acrylamide

Page 21: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Personal Safety

• Know the nearest emergency eye-wash and shower• Never Pipette by mouth• Do not use any equipment unless you are familiar

with its working• If you are leaving a lab unattended turn off all the

burners and lock all the doors• Working alone in the lab is not recommended- have

a lab-buddy• Smoking is not allowed inside buildings

Page 22: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Always protect your eyes

Protection against splattering chemicals, airborne objects and dangerous light

Safety glasses with side eye shields

Splash goggles

Full face shields: wear goggles underneath if you are handling strong corrosive chemical

Page 23: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Eyewear continued…

The eyewear must meet standards put forth by

ANSI (American National Standards Institute)

Such eyewear has Z87.1 imprinted on the frame or lens

Page 24: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Most common Hazard to your Eyes

Splashing liquid droplet while popping open an Eppendorf/ microfuge tube!!!

1. At the eye-wash station: Forcibly hold your eye open and rinse the inner part for 15 minutes

2. Obtain medical attention

3. Report to Katie, Archana or Dr. Leighton

Page 25: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

GlovesKnow the characteristics of the different glove types

and understand the hazards of the chemicals involved in each procedure

Always wash your hands thoroughly with soap and water:

when changing into fresh glovesafter working with any hazardous substances before eating or handling food/ coffee mugsafter you finish all your work and are ready to leave

for the day

Page 26: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Choosing the correct gloves

NO GLOVE MATERIAL IS IMPERMEABLE TO ALL CHEMICALS!!!

Consult the MSDS to choose the right gloves!

Natural rubber/ latex Acetone, Alcohols, Alkalies and Caustics, Ammonium fluoride, Dimethyl sulphoxide (DMSO), Phenol, Plating solutions

Neoprene Alcohols, Alkalies and caustics, Cellosolve, Degreasing solvents, Mineral acids, Oils, Plating solutions

Nitrile rubber Alcohols, Ammonium fluoride, Freons Hexane, Hydrofluoric and hydrochloric acid Perchloric acid Perchloroethylene Phosphoric acid, Potassium and sodium hydroxide

Page 27: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Gloves continued…

• Always wear gloves for handling media or liquids containing Se- compounds

• Always remove gloves before- Answering telephone

Walking in the hallway (unless you are carrying something that requires gloves).

Touching anything like keyboards, door-knobs etc.

Page 28: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Allergies due to Latex Gloves

Not uncommon- could appear after repeated use

Rash that appears on hands and stops at wrists Increased risk to people with a history of

asthama, allergic rhinitis, eczema Try nitrile gloves or wear cotton glove liners Dry hands thoroughly after washing and

apply topical medicated ointment/ hand lotion

Page 29: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Protective clothing/ Lab coats

Consult the MSDS for specific material (choice of disposable lab-coats):

Lab coats as essential• to avoid burning hazard: while working with an

open flame, heating block, autoclave or while pouring media

• for protection against spills: of toxic/corrosive chemical and biological cultures

• to avoid entanglement of clothes in machinery: especially if you are wearing loose clothing

Do not wear them outside the lab- in public areas!!!

Page 30: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Shoes

Shoes should be worn at all times

Not mandatory by recommended:

Sandals, open-toed shoes, and shoes with woven uppers, increase the risk of exposure due to the danger of spillage of corrosive or irritating chemicals.

Page 31: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Respiratory protection/ Safety Masks

• While working with hazardous chemicals always choose the fume hood

• To avoid irritating (non-toxic) dust/powder from getting into your respiratory system choose the blue dust masks

• Wear the mask first and then the gloves. • Always remove the gloves first, then wash your

hand and then remove the mask• Consult the MSDS to check if you require special

kind of masks with specific filters etc.

Page 32: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

General lab safety

• Keep aisles clear in the lab• Maintain unobstructed access to all exits,

emergency showers, eyewashes, fire extinguishers and electrical panels

• Bottle, burners, equipment, heating blocks etc should be kept away from edges of counters

• Never leave gas burners and hot plates unattended

Page 33: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Summary: Practicing safe science

• Know your protocol, execute procedures meticulously

• Know about all the chemicals involved- read MSDS• Use smaller quantities or choose safer chemicals if

possible• Avoid splash hazards- do not flick open eppendorfs• Wear safety clothing, gloves, glasses• Use chemical hood to protect from fumes or for

handling large quantities of hazardous chemicals• Be alert and maintain concentration

Page 34: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Using Chemical / Fume Hood

Chemical Hood

Page 35: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Using laboratory chemical hoods

• Plan your experiment: assess the risks of your experiment and place everything you need in the hood before starting.

• Lower the sash. Always make sure the sash is pulled down to the marked level. The best protection is provided when the sash is brought to the lowest level for convenient operation.

• Watch your activity. Use slow and deliberate motions. Place supplies so that they do not obstruct the airflow at the airfoil sill or the exhaust slots at the back of the hood. Do not work within four inches of the airfoil sill.

Page 36: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Performance of Chemical Hoods

The performance of a chemical hood can get compromised due to:

• Room air drafts/ open doors/ open windows• rapid hand movements into and out of the hood,• obstructions at the airfoil sill can affect. • someone closing a door / walking by can create drafts

that cause vapor to escape from the hood.Suggestion: When planning to do a hazardous experiment, you should ask

your colleagues to reduce activities such as walking past the hood or opening and closing the lab doors while you are working.

Page 37: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Emergencies

• Always be prepared!• Emergency response: Know the locations of

Eyewash fountains and emergency showers.

Fire Extinguishers

Emergency telephone numbers. Emergency exits and evacuation routes. Spill kits.

Page 38: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Fires

Fire is the most potentially devastating emergency in the modern biology laboratory. It is imperative that you know how to prevent fires and be prepared to respond should a fire occur.

Page 39: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Preventing fires

Use of flammable solvents is a primary cause of lab fires

• Use the smallest quantities of flammable solventspracticable.

• Store stock quantities in flammables storage cabinets• Separate flammable solvents from sources of

ignition: never use a Bunsen burner in any area where flammable solvents are handled.

Page 40: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Fighting small fires

• Always pull the fire alarm first• Turn of any electrical equipments/ burners in the

area and stay on the exit side of the room (near a door)

• Most of the extinguishers are labeled BC or ABC- direct the extinguisher at the base of the fire

• If you are unable to put of the fire try to confine it • If you are able to put of the fire stay around to talk

to UCPD and to make report

Page 41: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Types of fire extinguishers• Class A Extinguishers will put out fires in

ordinary combustibles, such as wood and paper.• Class B Extinguishers should be used on fires

involving flammable liquids, such as grease, gasoline, oil, etc.

• Class C Extinguishers are suitable for use on electrically energized fires.

• Class D Extinguishers are designed for use on flammable metals and are often specific for the type of metal in question.

Page 42: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Clothing Fire

Your co-worker spilled ethanol and his/ her clothing caught fire:

1. Put out the fire: Use Blanket or make him/her roll on the floor to smother fire

2. Chill the burns with ice water3. Seek medical attention (Tang or Alta

Bates) and report the incident to your supervisor

Page 43: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Emergency procedures: Major lab fire

1. Alert people to evacuate the area

2. Activate nearest fire alarm or call for emergencyresponse.

3. Close lab doors to confine fire.

4. Have a person who is knowledgeable about the lab and the incident ready to assist emergency personnel.

Page 44: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Emergency procedures: Evacuation after a Fire Alarm

• Leave immediately if you hear fire alarm.

• Always close your door, electrical equipments, burners

• Do not use elevators

• Go to the designated meeting areas

• Do not re-enter unless the fire department declares that it is safe to do so

Page 45: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Emergency procedures: Earthquake

• Duck under nearest sturdy object until shaking stops

• If you are in a doorway- brace yourself against the frame

• Avoid tall book cases/ shelves• Exit when shaking stops- always use staircases• Do not operate electrical appliances/ burners-

due to possible gas leaks

Page 46: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Emergency procedures: Bomb Threat

• Report any Bomb Threat ASAP to Carol or UCPD

• Be calm and evacuate immediately as directed by emergency personnel- Take your belongings with yourself

• Check work area for unfamiliar items as you leave

Page 47: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Hazardous Chemical spills

Do not attempt to clean the spill

• If you lack the knowledge to do it safely

• You do not have the appropriate material required for clean-up

• The spill is larger than 1 liter

• You feel physical symptoms: eye irritation, breathing difficulty, dizziness, nausea etc.

Page 48: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Emergency procedures: Hazardous Chemical spills

• Isolate the spill area

• If the spill is very large- notify the people in labs directly below your lab

• Refer to the yellow Flip chart

• Call EH&S or 9-911 after Hours/ holidays

• Be ready with the MSDS information for that material

Page 49: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Emergency procedures: Medical

• Remain calm.

• Initiate lifesaving measures if required.

• Call for emergency response.

• Do not move the person unless there is danger of further harm.

• Keep the injured person warm.

Page 50: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Emergency Response: Eye Exposure

• First aid: Flush at the eye-wash station for minimum 5 to 15 minutes maximum by forcing the eye(s) open

• Minor injuries- Tang Center• Major Injuries- Alta Bates: Have someone

who knows about the incident accompany the victim

Report to Dr. Leighton / Katie/ Carol

Page 51: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Emergency Response: Skin Exposure

• First Aid: Wash exposed area (use Shower if required) for minimum 5 to 15 minutes maximum. Get help if possible.

• Remove contaminated clothing to protect skin from further exposure

• Wrap the person in a dry blanket after the shower• Tang center / Alta bates• Report the incident to Dr. Leighton/ Katie/ Carol

Page 52: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Emergency Response: Respiratory Exposure

• Bring the victim to fresh air• Life-threatining injuries to be reported to 911 or 9-

911• Non-life-threatening to Tang Center/ Alta bates• Inform the medical responder about the nature of

the air-borne hazards so they may take precautions during resuscition procedures

Page 53: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Ethidium Bromide• EB is a potent mutagen: absorbed through skin,

nose, eyes and mouth (Read MSDS)• Pure EB should only be handled in a fume hood:

with the user wearing protective equipment that includes a lab coat, closed-toe shoes, chemically resistant gloves, and chemical safety goggles (not just safety glasses)

• Nitrile is an effective barrier to short-term exposure to EB. Use 100% nitrile gloves!

• Wash hands after removing their gloves, even if the gloves are not punctured

Page 54: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Substitutes for Ethidium Bromide?

New fluorescent dyes have been developed that manufacturers, such as Molecular Probes Inc. and FMC Bioproducts, claim are less toxic and can detect nucleic acid components at lower concentrations than EB.

Page 55: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Exposure to Ethidium Bromide• Eyes: immediately go to the emergency eyewash

flush eyes by forrcing them open for at least 15 • Skin contact: immediately wash the affected area

with soap and cold or cool water for 15 minues. • inhalation of EB dust: move him to an area where

he can breathe fresh air. • In all three cases the affected person should

immediately seek a medical evaluation from Tang Center or from Alta Bates Hospital if the exposure occurs while Tang Center is closed

Page 56: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Laboratory Injuries and Physical hazards to Research

workers

Page 57: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Avoiding Physical injuries

1. Good laboratory practice and common sense:

Staying alert- take a break and relax if you are tired.

Thinking about where the hazards are.

Keep floors dry and uncluttered to prevent slips, trips, and falls

Whenever possible, open flames should be replaced by electrical heating

Page 58: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Minor Cuts and Injuries

. • First aid: Vigorously wash with soap and water for several minutes

• Apply first aid antibiotic/ ointment• Obtain medical attention- ever if there is no

exposure to hazardous substance• Report to Dr Leighton/ Katie/ Carol

Page 59: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Muscle and Bone Injuries

• The second most common serious injuries: strains and fractures due to falls and improper lifting of heavy objects

Page 60: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Specific Hazards

• Autoclave Hazards

• Centrifugation Hazards

• High Voltage equipment hazards

Page 61: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Autoclave Hazards

Physical hazard due to steam, heat and pressure• Make sure seals on containers of liquids are loose

so vapor expanding during heating will not cause an explosion

• Never autoclave any flammable or volatile liquids because they could explode ( never autoclave anything that has bleach on it)

• Never autoclave anything that says non-autoclavable or if you are not sure

• For specific instructions: Contact Katie

Page 62: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Using autoclaves • Use loading racks: Never place any item directly on the

bottom or floor of the autoclave• Starting the sterilization cycle: close the door of the

autoclave fully choose correct cycle before starting the sterilization

• Unloading the autoclave: wear heat-resistant gloveswait for the “complete” signFirst, slightly crack open the door -wait a full five for

autoclave loads with just glassware and ten minutes before unloading liquids.

let the glassware stay outside for 15 minutes before handling the individual pieces.

Page 63: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Centrifugation Hazards

• Personal injury is infrequent and usually associated with improper lifting techniques to move heavy rotors

• 90 % of the problems occur due to user errors

• Carelessness can result in sample loss or damaged equipment

• It require careful use, maintenance and careful bookkeeping

Page 64: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

High Voltage Equipment

Electrophoresis equipment

• Read all the instructions carefully- right next to the electrophoresis equipment

or at EH&S website: http://www.ehs.berkeley.edu/pubs/helpsheets/04electro.html

Page 65: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Electrophoresis Equipment

General safety with electrophoresis equipments:• Switch power off before making any connection• Handle power leads one at a time and with one

hand only- make sure your hands are dry• Beware of loose connections- they lead to sparks • Keep equipment away from sink or wet area• If you feel a tingle when you touch the unit- stop

using it or wait until it is repaired

Page 66: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Working with microbes

• In our labs in Mulford hall (303/307 and 330) we work strictly with non- pathogens

• Any known or suspected pathogens, their DNA’s, amplicons etc. should be handled in LL45 in Koshland hall. This is a designated area with limited access and all people using this area should read “Leighton Laboratory Bio-safety Manual” and discuss specific issues with Dr. Leighton or Archana

Page 67: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Pipetting technique• Never pipette by mouth!!!• Discharge pipettes against the flask or tube wall to avoid

splashes. • Use disposable pipettes only for microbial cultures and

procedure (use glass pipettes for organic chemicals and corrosive agents)

• Pipettes used for any microbial cultures should be treated with 10 % bleach solution before discarding them as biohazard waste

• Leave them in brown box separately for trash pick-up (Ask Bill if you do not know the location of this box)

• Dispose glass pipettes and broken glass in “Broken glass containers”

Page 68: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

BIOHAZARDS

• Stay away from designated refrigerators, freezers and room marked with this sign unless you are authorized to work in such areas (you are working with known/ suspected pathogens!)

Page 69: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Non- medical sharp waste

• Sharps such as blades, needles, scalpels should be handled as “Biohazard sharp wastes”

• Placed in puncture-resistant containers labeled “ Sharps waste” or “Biohazard”

• Do not over fill these containers• Tape them close and call EH&S for a pick-up!

Page 70: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Autoclaving Biotechnology wastes (non pathogenic plates only)

• Dispose in white designated bins lined with white autoclavable bags labeled non-medical wastes

• Fill only to 2/3 rd for proper sterilization• Double-bag and make 2 small slits in the inner

bag- close both bags without making them air-tight

• Autoclave for 35 minutes on liquids after 5:00 p.m on a weekday ( weekend: anytime)

• Dispose in regular trash in the dumpsters on the North side of the building

Page 71: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Drain Disposal of Non-Pathogenic wastes

• Liquid cultures and stocks of non-pathogenic bacteria could be treated with 10% bleach for 30 minutes before disposing in the drain.

• Never dispose cultures or stocks of pathogenic-bacteria (even after treating with bleach)

• Never put bleach-containing solution in autoclave this could cause explosion!!!

Page 72: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Disposing Biohazard Wastes• Sharps: are contained in leakproof, rigid,

puncture-resistant, durable plastic containers. These containers are red in color and equipped with a tight-fitting lid. EH&S to be notified for pick-up.

• Free flowing liquid waste: is treated with chlorine bleach (10% final concentration) and contained in leakproof, rigid durable containers for EH&S pick-up

• Solid biohazardous waste is collected in plastic waste bags (red or white) to be placed into the autoclave. White is disposed with trash and red should be disposed in designated bins for EH&S pick-up.

Page 73: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

Important Contacts

• Dr. Leighton

• Carol Wehr

• Katie Wheeler

• Archana Sudame

• EH&S

• UCPD (emergency)

• UCPD (non-emergency)

Page 74: SAFETY MEETING LEIGHTON LABORATORY -Prepared by Archana Sudame.

References

• http://www.ehs.berkeley.edu/

• http://www.practicingsafescience.org (Yale)

• http://rehs.rutgers.edu/ (Rutgers)

• http://www.pp.okstate.edu/ehs/index.htm (Oklahoma State)