World Class Heat Stress Detector twl1s
15
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

World Class Heat Stress Detector

twl1s

Page 2: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S
Page 3: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

thermal Work limitB!"#$r%&'(

© Scarlet Tech Co. Ltd. 2013 www.scarlet.com.tw +886 2 2325 7712

Dehydration caused by heat stress is dangerous. Heat stroke and other serious issues will be inducedHAAD conducted safety in the heat program and introduced TWL as a big enhancement

Heat index invented by Australia Dr. BatesTWL unit W/m2 , means a safe maximum metabolic rate suitable for a given environment conditionConsider clothing factor and human physiological statusCalculated from four parameters(1) dry bulb temperature (DB)(2) wet bulb temperature (WB)(3) globe bulb temperature (GT)(4) wind speed (WS)

what TWL is? why twl?

Page 4: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

four instrumentsM)!*&r) +!r!,)-)r*

The temperature of air measured by a thermometer freely exposed to the air but shielded from radiation and moisture. DBT is the temperature that is usually thought of as air temperature, and it is the true thermodynamic temperature.

Dry bulb

The temperature a parcel of air would have if it were cooled to saturation (100% RH) by the evaporation of water into it. It describes the level of moisture and it affects how people ‘feel’ the environment. In TWL theory, higher wet bulb temp. means harder sweat evaporation and put worker in hazard.

wet bulb

Wind speed is typically judged as the velocity of wind. Most measurements of air movement are taken of outside air, and there are several factors that can affect it. Average wind speed is often determined by an anemometer. Wind helps to remove the heat from human body and plays important role in TWL calculation.

wind speed

Globe bulb is typically used to measure MRT (Mean Radiation Temperature). MRT is the most important parameter governing human energy balance, especially on hot sunny days. In fact, in warm climates it is about twice as significant as the air temperature due to lighter clothing, while in cooler climates it has about the same influence as the air temperature.

globe bulb

© Scarlet Tech Co. Ltd. 2013 www.scarlet.com.tw +886 2 2325 7712

Page 5: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

one calculatorC!."&.!-) TWL v!.&)

© Scarlet Tech Co. Ltd. 2013 www.scarlet.com.tw +886 2 2325 7712

Page 6: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

one tableC/)"# -/) ,)!'0'$

Health Authority Abu Dhabi (HAAD) conducted medical research and came along with the following table to give working sites a general guideline to manage the safety in the heat. The sheet is suitable for self-paced workers who has been acclimatized and trained.

Zone Risk Level Cycle (min)

TWL ≥ 140 Low Continuous*

115 ≤ TWL < 140 Medium Continuous*

TWL < 115 High 20 work - 40 rest

© Scarlet Tech Co. Ltd. 2013 www.scarlet.com.tw +886 2 2325 7712

Page 7: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

everything in one deviceB)*- *%.&-0%'

four sensors

wet bulb measure RH: 5-95% accuracy 0.1%

calculator

globe 0-80℃, accuracy 0.1℃

Wind 0.5-10 m/s, accuracy 0.1 m/s

Dry bulb 0-50℃, accuracy 0.1℃

© Scarlet Tech Co. Ltd. 2013 www.scarlet.com.tw +886 2 2325 7712

tableZone Risk Level Cycle (min)

TWL ≥ 140 Low Continuous*

115 ≤ TWL < 140 Medium Continuous*

TWL < 115 High 20 work - 40 rest

Page 8: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

why ScarletB)*- *%.&-0%'

© Scarlet Tech Co. Ltd. 2013 www.scarlet.com.tw +886 2 2325 7712

we do more for you

Page 9: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

dashboardB)*- *%.&-0%'

© Scarlet Tech Co. Ltd. 2013 www.scarlet.com.tw +886 2 2325 7712

3-color LCD backlight R/Y/G indicates risk levelRisk icons is readable alternative in sunlightOn screen timer is helpful for safety manager to schedule work-rest cycle based on TWL value

innovative display

Page 10: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

warningB)*- *%.&-0%'

© Scarlet Tech Co. Ltd. 2013 www.scarlet.com.tw +886 2 2325 7712

Red zone (TWL < 115) detectedWork timer expired

remote technology critical event warning

433 MHz transmitter integratedPager (receiver) in box200 meter guarantee in open space Diameter of a cricket stadium is 200 mRF is designed for horizontal transmission

200 m

Page 11: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

data loggerB)*- *%.&-0%'

© Scarlet Tech Co. Ltd. 2013 www.scarlet.com.tw +886 2 2325 7712

logger TWLIT

For research purposeFor build up database of forecastConfigurable sample rate: 10 min to 4 hr/dataStandard mini USB connector

PC software to download data and setup device Download data in zero click. SimpleConfigure device nameConfigure sampling rateExport CSV for Excel analysis

210

255

300

12.06 12:36 13:06 13:36

TWL RH !normalized"

Page 12: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

sensor protectionB)*- *%.&-0%'

© Scarlet Tech Co. Ltd. 2013 www.scarlet.com.tw +886 2 2325 7712

protect rh sensor

Polypropylene (PP) film allows vapor going through but blocks fine dust and dirt. So vapor and moisture reach sensor but particles don’t. This design is to extend the life of sensor in harsh environment.

Protect anemometer bearing

A silicone pad clamped on top of the plate of wind miller plate. This prevents the bearing inside of the structure from dust and other particles.Compare to competitors, this effectively extends the sensor life.

Page 13: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

calibration & partsS)rv0")*

© Scarlet Tech Co. Ltd. 2013 www.scarlet.com.tw +886 2 2325 7712

humidity wind cup

>> Calibration Should calibrate every 6 months. Local agent or clients can do it.

>> PartsPp filter is suggested to be replaced every 2 to 4 weeks in heavy usage. By order.

Dry/globe bulb

>> Calibration Calibration drift of thermistors are negligible. No need to calibrate.

>> PartsBlack ball along with thermistor is replaceable. By order.

>> Calibration Local calibration is not feasible due to wind tunnel costs.

>> Quick checkHold device and walk 5 meters in 10 sec and make sure the cups keep rotating.

>> PartsWind cup and bearing is replaceable. By order.

Page 14: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

CertificateB)*- *%.&-0%'

© Scarlet Tech Co. Ltd. 2013 www.scarlet.com.tw +886 2 2325 7712

EN 61326-1:2006(IEC/EN61000-4-2 (2009)/

-3 (2006 + A2:2010)) Electrical Equipment for Measurement,

Control and Laboratory Use

Page 15: Safety in the Heat - Thermal Work Limit and Scarlet Tech TWL-1S

thank you