In your community, there may be industrial waste disposal wells, storm water drainage wells, large-capacity septic systems, and other Class V wells. They are regulated and are not allowed to endanger drinking water resources. DRINKING WATER RESOURCES DRINKING WATER RESOURCES OIL SALT LAYER CHEMICAL PLANT WASTE WATER TREATMENT PLANT TREATED MUNICIPAL WASTE WATER BASE OF UNDERGROUND SOURCES OF DRINKING WATER BASE OF UNDERGROUND SOURCES OF DRINKING WATER BASE OF UNDERGROUND SOURCES OF DRINKING WATER BASE OF UNDERGROUND SOURCES OF DRINKING WATER BRINE DISPOSAL BRINE DISPOSAL ENHANCED RECOVERY OIL & GAS RECOVERY SALT SOLUTION MINING SALT MINING URANIUM SOLUTION MINING URANIUM MINING SCHOOL STORM WATER DRAINAGE STREET DRAINAGE LIGHT INDUSTRY APARTMENT BUILDING LARGE-CAPACITY SEPTIC SYSTEMS AUTOMOTIVE SERVICE STATION CONCENTRATED ANIMAL FEEDING OPERATION FARM HOUSE LARGE-CAPACITY CESSPOOL FOOD PROCESSING DRINKING WATER PLANT Class I wells- Isolate hazardous, industrial and municipal wastes through deep injection Class II wells- Inject oil and gas production wastes Class III wells- Minimize environmental impacts from solution mining operations Class V wells- Manage the shallow injection of all other fluids to prevent contamination of drinking water resources Class V wells continued DRINKING WATER RESOURCES 100 FEET 100 FEET AVERAGE = 4000 FEET PRODUCTION WELL* INDUSTRIAL WASTE AGRICULTURAL DRAINAGE WELL PUBLIC WATER SUPPLY WELL MOTOR VEHICLE WASTE DISPOSAL WELL AUTOMOTIVE SERVICE STATION Class IV wells- Prevent ground water contamination by prohibiting the shallow injection of hazardous waste except as part of authorized cleanup activities Safe Drinking Water Act Underground Injection Control (UIC) Program Protecting Public Health and Drinking Water Resources SOURCE WATER PROTECTION AREA SHOPPING MALL LIGHT INDUSTRY WITH HOLDING TANKS FOR OFF-SITE WASTE DISPOSAL AGRICULTURAL ACTIVITIES WITH BEST MANAGEMENT PRACTICES CONFINING FORMATION CONFINING FORMATION CONFINING FORMATION CONFINING FORMATION CONFINING FORMATION HAZARDOUS AND NON-HAZARDOUS INDUSTRIAL WASTES *PRODUCTION WELLS ARE NOT REGULATED BY THE UIC PROGRAM PRODUCTION WELL* *PRODUCTION WELLS ARE NOT REGULATED BY THE UIC PROGRAM HAZARDOUS WASTE All large-capacity cesspools are banned. New motor vehicle waste disposal wells are banned nationwide. Existing motor vehicle waste disposal wells in source water protection areas or other sensitive ground water areas must close or receive a permit. United States Environmental Protection Agency Office of Water (4606) Washington, DC 20460 EPA 816-H-01-003 August 2001 www.epa.gov/safewater
2
Embed
Safe Drinking Water Act - ndep.nv.gov · SALT SOLUTION MINING SALT MINING ... Safe Drinking Water Act Underground Injection Control ... vehicle waste disposal wells in source water
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
In your community, there may be industrial waste disposal wells, storm water drainage wells,
large-capacity septic systems,and other Class V wells.
They are regulated and arenot allowed to endanger drinking water resources.
DRINKINGWATER
RESOURCES
DRINKING WATERRESOURCES
OIL
SALT LAYER
CHEMICALPLANT WASTE WATER
TREATMENT PLANT
TREATEDMUNICIPAL
WASTE WATER
BASE OFUNDERGROUND
SOURCES OFDRINKING WATER
BASE OFUNDERGROUND
SOURCES OFDRINKING WATER
BASE OFUNDERGROUND
SOURCES OFDRINKING WATER
BASE OFUNDERGROUND
SOURCES OFDRINKING WATER
BRINEDISPOSAL
BRINEDISPOSAL
ENHANCEDRECOVERY
OIL & GASRECOVERY
SALTSOLUTIONMINING
SALTMINING
URANIUMSOLUTIONMINING
URANIUMMINING
SCHOOL
STORM WATERDRAINAGE
STREETDRAINAGE
LIGHTINDUSTRYAPARTMENT
BUILDING
LARGE-CAPACITYSEPTIC SYSTEMS
AUTOMOTIVESERVICE STATION
CONCENTRATED ANIMALFEEDING OPERATION
FARM HOUSE
LARGE-CAPACITYCESSPOOL
FOOD PROCESSING
DRINKING WATER PLANT
Class I wells-Isolate hazardous,
industrial and municipalwastes through deep injection
Class II wells-Inject oil and gasproduction wastes
Class III wells-Minimize
environmental impactsfrom solution mining
operations
Class V wells-Manage the shallow injection of all other fluids to prevent
contamination of drinking water resources
Class V wells continued
DRINKING WATERRESOURCES
100
FEET
100
FEET
AVER
AGE
= 40
00 F
EET
PROD
UCTI
ON W
ELL*
INDUSTRIALWASTE
AGRICULTURALDRAINAGE WELL
PUBLICWATERSUPPLYWELL
MOTOR VEHICLEWASTE
DISPOSAL WELL
AUTOMOTIVESERVICE STATION
Class IV wells-Prevent ground water
contaminationby prohibiting
the shallow injection of hazardous wasteexcept as part of
authorizedcleanup activities
Safe Drinking Water ActUnderground Injection Control (UIC) ProgramProtecting Public Health and Drinking Water Resources
*PRODUCTION WELLS ARE NOTREGULATED BY THE UIC PROGRAM
PROD
UCTI
ON W
ELL*
*PRODUCTION WELLS ARE NOTREGULATED BY THE UIC PROGRAM
HAZARDOUSWASTE
All large-capacitycesspools are banned.
New motor vehicle wastedisposal wells are
banned nationwide.Existing motor vehiclewaste disposal wells insource water protectionareas or other sensitive
ground water areas mustclose or receive a
permit.
United StatesEnvironmental ProtectionAgency
Office of Water(4606)Washington, DC 20460
EPA 816-H-01-003August 2001www.epa.gov/safewater
Safe Drinking Water ActUnderground InjectionControl (UIC) Program
Protecting Public Health and DrinkingWater Resources
WHY DO WE HAVE A PROGRAM TO REGULATEUNDERGROUND INJECTION?Each year Americans generate large amounts of wastefluids. More than 750 billion gallons of hazardous and non-hazardous fluids are disposed of safely through under-ground injection. The Underground Injection Control (UIC)Program is designed to protect underground sources ofdrinking water (USDWs) and provide a safe and cost-effective means for industries, municipalities, and smallbusinesses to dispose of their wastewater, extract mineralresources, and store water for the future. Illegal dischargeshave the potential to contaminate our underground drinkingwater resources. Preventing this contamination is vitalbecause most accessible fresh drinking water is foundunderground in shallow formations called aquifers. Aquifersprovide water for more than 90 percent of the public watersystems in America. They also supply agricultural wells,feed our lakes, and help recharge our streams and rivers,particularly during dry periods. In addition, millions ofAmericans living in rural areas rely on private wells thatdraw their water from aquifers. Safe and clean drinkingwater resources are essential for our growing population.Protecting future drinking water resources is essential forcontinued growth. The UIC Program prevents contaminantsfrom entering our drinking water resources to protect ourpublic health.
WHAT ARE INJECTION WELLS?
An injection well is any bored, drilled, or driven shaft, or dughole, whose depth is greater than its largest surfacedimension; an improved sinkhole; or a subsurface distribu-tion system used to discharge fluids underground. Thesewells range from deep, highly technical, and more frequentlymonitored wells to shallow on-site drainage systems, suchas septic systems, cesspools, and storm water drainagewells. There are five categories or “classes” of injectionwells based on function, construction, and operatingfeatures.
WHAT IS THE STATUTORY BASIS FOR THE UICPROGRAM?In 1974, Congress passed the Safe Drinking Water Act(SDWA). Part of SDWA required the U.S. EnvironmentalProtection Agency (EPA) to report back to Congress onwaste disposal practices, and develop minimum federalrequirements for injection practices that protect publichealth by preventing injection wells from contaminatingUSDWs. USDWs are defined as aquifers or portions ofaquifers that have a sufficient quantity of ground water tosupply a public water system and contain fewer than 10,000milligrams per liter (mg/l) or parts per million (ppm) totaldissolved solids (water that can be treated to drinking waterstandards). This includes all current and future undergrounddrinking water resources.
HOW DOES THE UIC PROGRAM PROTECT PUBLIC HEALTH? WHO IMPLEMENTS THE UIC PROGRAM?
States and tribes may apply to EPA to obtain primaryenforcement responsibility, or primacy, to administer the UICProgram. Primacy programs must meet the minimumfederal requirements, but may have more stringent require-ments. Thirty-three states, Guam, the Commonwealth of theMariana Islands, and Puerto Rico have primacy for allclasses of injection wells. Seven states share primacy withEPA. EPA directly implements the UIC programs for theremaining states, the Virgin Islands, American Samoa, andIndian Country.
WHAT CAN YOU DO TO PROTECT YOUR DRINKINGWATER?Preventing contamination can save you money and protectyour family’s health. Here are some of the things you can doto help protect your drinking water source:
n Know where your drains go. Many homes orbusinesses use septic systems or drywells for wastedisposal. These systems are designed for householdsanitary wastes only.
n Become involved in Source Water Protection.Every state is conducting Source Water Assessmentsfor its public water systems. These assessments willidentify the major potential sources of contamination(including Class V wells) to public drinking watersupplies. The results will be provided to the public.Communities will use this information to plan protec-tion activities and identify Class V wells for propermanagement to prevent contamination of drinkingwater sources. The UIC Program has banned motorvehicle waste disposal wells in source water protec-tion areas. States are also encouraged to target theseareas for UIC protective measures.
n Read your consumer confidence report. Thisreport, published once a year by the agency providingyou with your drinking water, gives you informationabout the quality of your drinking water and informa-tion about your state’s source water assessment foryour system, when it has been completed.
FOR MORE INFORMATION:
Call the Safe Drinking Water Hotline (800) 426-4791 or theOffice of Ground Water and Drinking Water (202) 260-7077;write to The UIC Program, Mail Code 4606, U.S. EPA, 1200Pennsylvania Avenue, NW, Washington, D.C. 20460; or visitthe Web site at http://www.epa.gov/safewater/uic.html.
DEFINITIONS
IMPROVED SINKHOLE – A naturally occurring depression or other naturalcrevice (for example, those found in limestone or volcanic rocks),which has been modified for the purpose of directing and dischargingfluids underground.
SUBSURFACE DISTRIBUTION SYSTEM – An assemblage of perforated pipes,drain tiles, or other similar mechanisms intended to distribute fluidsbelow the ground surface.
AUTHORIZATION BY RULE – An owner or operator of an injection well whosubmits proper inventory information to the UIC regulatory authoritymay construct or use his or her well as long as the injection activitydoes not endanger USDWs.
NON-ENDANGERMENT – No owner or operator shall construct, operate,maintain, convert, plug, abandon, or conduct any other injection ac-tivity in a manner that allows the movement of fluid containing anycontaminant into USDWs, if the presence of that contaminant maycause a violation of any primary drinking water regulations or mayadversely affect the health of persons.
EPA established the UIC Program to set minimum federal requirements for allinjection wells that discharge hazardous and non-hazardous fluids above,into, or below USDWs. They affect the siting, construction, operation, mainte-nance, monitoring, testing, and closure of injection wells. All operationalinjection wells require authorization under general rules or specific permits.Fluids cannot be injected if they may endanger a drinking water source.
n Class I wells - Isolate hazardous, industrial and municipal wastesthrough deep injection. Class I wells inject hazardous and non-hazardous wastes into deep, isolated rock formations below thelowermost USDW. There are specific siting, construction, operating,monitoring and testing, reporting and record keeping, permitting, andclosure requirements for all Class I wells. There are two main types ofClass I wells: hazardous waste wells and non-hazardous waste wells.
n Class II wells - Inject oil and gas production wastes and materials.Class II wells inject fluids associated with oil and natural gas produc-tion. Most of the injected fluid is brine pumped to the surface along withoil and gas. This brine is often saltier than seawater and can containtoxic metals and radioactive substances. By injecting the brine, Class IIwells prevent surface contamination of soil and water. In addition, welloperators inject residual brines, steam, polymers, and other fluids toenhance the production of oil and gas. Class II well operators mustfollow strict construction and conversion (from production wells)requirements, except when historical practices in the state and geologyallow for different standards. Class II wells are permitted or authorizedby rule; the well owner or operator must meet all applicable require-ments; and the wells are tested and inspected regularly. There areabout 147,000 Class II wells in operation in the United States.
n Class III wells - Minimize environmental impacts from solutionmining operations. Class III wells inject fluids into rock formations todissolve and extract minerals. The injected fluids are pumped to thesurface and the minerals in solution are extracted. Generally, the fluid isrecycled into the same formation for further mineral extraction. Morethan 50 percent of the salt and 80 percent of the uranium extraction inthe United States involves Class III injection wells. These wells arepermitted or authorized by rule. Class III well owners or operators mustcase and cement their wells, and the wells must be tested regularly.There are about 190 mining sites with approximately 17,000 Class IIIwells operating in the United States.
n Class IV wells - Prevent ground water contamination by prohibitingthe shallow injection of hazardous waste except as part of autho-rized cleanup activities. Class IV wells were shallow wells used toinject hazardous or radioactive wastes. They are banned except whenoperated to inject treated contaminated ground water back into theoriginal aquifer. These wells can be operated only with federal or stateapproval under the RCRA or Superfund programs. There are about 40waste cleanup sites with Class IV wells in operation in the U.S.
n Class V wells - Manage the shallow injection of all other fluids.Class V wells are injection wells that are not included in Classes Ithrough IV. Class V wells inject non-hazardous fluids into or above anaquifer. They are typically shallow, on-site disposal systems, such asfloor and sink drains that discharge into dry wells, septic systems, leachfields, and similar types of drainage wells, although there are someClass V wells that are deep injection wells. When properly designed,sited, operated, and maintained, Class V wells do not endanger drinkingwater sources. Most Class V wells are authorized by rule. An estimated500,000 to 685,000 Class V wells are in operation in the United States.Examples of Class V wells include the following:
NOTE: The UIC Program does not regulate sanitary discharges fromindividual residential septic systems and cesspools, and nonresiden-tial septic systems and cesspools that inject only sanitary waste andhave the capacity to serve fewer than 20 persons per day.
There are many other subcategories of Class V wells. Additional informationcan be found by visiting EPA’s UIC Program Web site at http://www.epa.gov/safewater/uic.html.