ANALYZED USING THE EQUIVALENT LATERAL FORCE PROCEDURE S S 1 DS Ss SITE SOIL CLASS SEISMIC DESIGN CATEGORY EXPOSURE B. STRUCTURE DESIGNED FOR THE FOLLOWING LOADS: ROOF DEAD LOADS: = D = D = 0.956 BASIC WIND SPEED (V) = 120 MPH = B IMPORTANCE FACTOR = I GROUND SNOW LOAD = 25 PSF ROOF LIVE LOADS: = 0.473 = 0.713 MOMENT-RESISTING FRAME SYSTEM: R = 3.5 STEEL ORDINARY MOMENT FRAMES WIND LOADS: SEISMIC DESIGN DATA: BASIC STRUCTURAL & SEISMIC RESISTING SYSTEM: A. STRUCTURE DESIGNED IN ACCORDANCE WITH THE 2014 OSSC. FLAT ROOF SNOW LOAD = 25 PSF (MODIFIED FOR DRIFTING AND UNBALANCED LOADS WHERE APPLICABLE) C. IF ANY FIELD CONDITIONS PRECLUDE COMPLIANCE WITH THESE DRAWINGS AND/OR CONDITIONS SPECIFIED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY AND SHALL NOT PROCEED WITH THE AFFECTED WORK. THE CONTRACTOR SHALL VERIFY ALL BUILDING DIMENSIONS, DETAILS, AND CONDITIONS PRIOR TO START OF CONSTRUCTION THAT MAY BE IMPACTED BY VARIATIONS FROM THE CONDITIONS SHOWN HEREIN. a. INSPECT FORM WORK AND PLACEMENT OF REINFORCEMENT K. REINFORCEMENT COVER, UNLESS NOTED OTHERWISE: NON-SHRINK GROUT SHALL CONFORM TO ASTM C-109. CONCRETE AGGREGATES SHALL CONFORM TO ASTM C-33. CONCRETE FILL = 1/2" MAXIMUM AGGREGATE SIZE: MAXIMUM WATER-CEMENT RATIO = 0.49 MAXIMUM SLUMP LIMIT = 4" FOOTINGS & FOUNDATIONS = 3/4" TO 1 1/2" SLAB-ON-GRADE = 3/4" TO 1" 1.) FOOTINGS AND GRADE BEAMS - BOTT. 3" 2.) WALLS - OUTSIDE 2", INSIDE 1" 3.) SLABS - 1 1/2" FROM TOP -TOP 1-1/2" JOINT MATERIAL, CONFORMING TO ASTM D-1751. A. ALL CONCRETE WORK SHALL CONFORM WITH A.C.I. "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", ACI 318 - LATEST EDITION, AND "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES", ACI 315 - LATEST EDITION. B. ALL CONCRETE FORM WORK WORK SHALL CONFORM WITH A.C.I. "RECOMMENDED PRACTICES FOR CONCRETE FORM WORK" - ACI 347. C. ALL CONCRETE SHALL HAVE MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 3000 PSI. ALL STRUCTURAL CONCRETE SHALL CONFORM WITH A.C.I. "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" - ACI 301. CEMENT SHALL BE PORTLAND CEMENT, TYPE I OR II, CONFORMING TO ASTM-C-150. EXPANSION JOINTS SHALL BE 1/2" THICK ASPHALT IMPREGNATED FIBERBOARD CURING COMPOUND SHALL BE CLEAR, CONFORMING TO ASTM C-309. E. COLD WEATHER CONCRETE WORK, WHEN APPLICABLE, SHALL CONFORM TO ACI 306. F. HOT WEATHER CONCRETE WORK, WHEN APPLICABLE, SHALL CONFORM TO ACI 305. H. ALL BAR REINFORCING FOR CONCRETE TO CONFORM TO ASTM A615, GRADE 60. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. AIR-ENTRAINING ADMIXTURES SHALL CONFORM TO ASTM C-260. I. CONCRETE ACCESSORIES TO BE ADEQUATE TO MAINTAIN REINFORCING ACCURATELY IN PLACE AND BE NON-CORROSIVE, NON-STAINING TYPE. L. WELDED WIRE FABRIC SHALL HAVE MINIMUM END AND SIDE LAPS OF 1'-0". J. LAP ALL BAR REINFORCING PER ACI 318. STAGGER SPLICES IN HORIZONTAL WALLS AND SLABS. GENERAL NOTES: SOIL NOTES: CONCRETE NOTES: FOR EACH DAY'S POUR FOR EACH TYPE OF CONCRETE. b. SLUMP PER ASTM C-143. ONE TEST AT POINT OF DISCHARGE d. CONCRETE TEMPERATURE - TEST EACH TIME A SET OF COMPRESSION TEST IS TAKEN. IN RESERVE FOR LATER TESTING IF REQUIRED. ALL CONCRETE WORK, REINFORCING PLACEMENT, FORM WORK AND SHORING SHALL BE SPECIAL INSPECTED BY AN INDEPENDENT TESTING AGENCY RETAINED BY THE OWNER FOR THE FOLLOWING ITEMS: CONCRETE SPECIAL INSPECTION REQUIREMENTS D. CONTRACTOR SHALL SUBMIT MIX DESIGNS FOR APPROVAL. MIX DESIGN SHALL INDICATE 7 AND 28 DAYS STRENGTHS, CEMENT CONTENT, AIR CONTENT, WATER-CEMENT RATIO, AMOUNT OF FINE AND COARSE AGGREGATES AND ADMIXTURES. ALL EXTERIOR CONCRETE AND CONCRETE EXPOSED TO WEATHER SHALL BE AIR-ENTRAINED (4% TO 6%) UNLESS LOCAL STANDARDS ARE OTHERWISE. e. COMPRESSION TEST SPECIMEN PER ASTM C-31 (ONE SET OF 4 STANDARD CYLINDERS) c. AIR CONTENT PER ASTM C-173 (VOLUMETRIC) OR ASTM C-231 (PRESSURE). ONE TEST FOR EACH DAY'S POUR FOR EACH TYPE OF CONCRETE. g. TWO SPECIMENS TESTED AT 7 DAYS, ONE SPECIMENS TESTED AT 28 DAYS, AND ONE SPECIMEN RETAINED h. EPOXIED ALL THREAD AND REBAR DOWELS; AND EXPANSION ANCHORS INTO CONCRETE. f. COMPRESSION STRENGTH TEST PER ASTM C-39. ONE SET FOR EACH DAY'S POUR FOR EACH TYPE OF CONCRETE PLUS ADDITIONAL SETS FOR EACH 100 cy OVER AND ABOVE THE FIRST 100 cy. M. HILTI HY 200 OR SIMPSON SET XP EPOXY ADHESIVE IS REQUIRED FOR ALL REBAR DOWELS OR ALL THREAD DRILLED AND EPOXIED INTO CONCRETE. A. SOIL BEARING CAPACITY USED IN DESIGN OF NEW FOUNDATION: 1500 PSF. ALL FOOTINGS TO BEAR A MINIMUM OF 18" BELOW FINISHED GRADE ON UNDISTURBED SOIL OR APPROVED STRUCTURAL FILL. PROVIDE AND INSTALL STRUCTURAL FILL AS NECESSARY. IF UNSUITABLE SOILS ARE ENCOUNTERED, OR IF ROCK IS ENCOUNTERED IN THE AREA OF THE PROPOSED BOTTOM OF FOOTING, NOTIFY THE ENGINEER IMMEDIATELY. B. THE GEOTECHNICAL ENGINEER SHALL OBSERVE AND APPROVE SUBGRADE SOILS PRIOR TO THE PLACEMENT OF STRUCTURAL FILL OR FOOTING FORMS. NOTE: B-E ARE NOT APPLICABLE IF GEOTECHNICAL REPORT IS NOT REQUIRED BY THE BUILDING OFFICAL D. PLACEMENT AND COMPACTION OF STRUCTURAL FILL SHALL BE OBSERVED BY THE GEOTECHNICAL ENGINEER AND/OR TEST RESULTS BY A QUALIFIED TESTING AGENCY. E. COMPLY WITH SPECIFICATIONS AND GEOTECHNICAL REPORT RECOMMENDATIONS FOR ALL FILLS AND EXCAVATIONS. C. STRUCTURAL FILL MATERIAL TYPE AND SOURCE SHALL BE APPROVED BY GEOTECHNICAL ENGINEER PRIOR TO INSTALLATION. ROOF (TOTAL) = 20 PSF G. SCREED SLABS AT GRADE LEVEL, MAINTAINING SURFACE FLATNESS OF MAXIMUM 1/4" IN 10'-0". C. ALL STEEL TUBE COLUMNS SHALL CONFORM TO ASTM A500, GRADE B. K. ALL BOLTS, NUTS, AND WASHERS SHALL BE IN ACCORDANCE WITH THE LATEST SPECIFICATIONS APPROVED BY THE RESEARCH COUNCIL ON RIVETED AND BOLTED STRUCTURAL JOINTS. A. STEEL SHALL CONFORM TO THE "SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, ALLOWABLE STRESS DESIGN AND PLASTIC DESIGN" LATEST EDITION, OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. H. ALL WELDS SHALL CONFORM TO THE "STRUCTURAL WELDING CODE (STEEL)," AWS D1.1, LATEST EDITION. i) COMPLETE-JOINT-PENETRATION WELDS (CJP) ARE TO BE CONSTRUCTED PER THE WELDERS PREFERENCE AND PER ANSI/AISC 341-05, 11.2a. a) BACKING IS TO BE REMOVED AND BACKWELDED WITH A 5/16" FILLET WELD. b) WHERE WELD ACCESS HOLES ARE PROVIDED, THEY WILL CONFORM TO AISC SPECIFICATION. G. ALL ANCHOR RODS SHALL CONFORM TO ASTM F1554 GRADE 36. F. ALL HEADED STUDS SHALL CONFORM TO ASTM A-108, GRADE 1015 OR 1020. E. ALL MISCELLANEOUS STRUCTURAL STEEL SHALL BE ASTM A36. B. STRUCTURAL STEEL SHALL CONFORM TO ASTM A992, EXCEPT AS MODIFIED BELOW. D. ALL STEEL PIPE COLUMNS SHALL CONFORM TO ASTM A53, TYPE E OR S, GRADE B, OR ASTM A501. STRUCTURAL STEEL NOTES: WOOD GENERAL NOTES: STRUCTURAL OBSERVATIONS: STRUCTURAL STEEL SPECIAL INSPECTION REQUIREMENTS I. BOLTS FOR STEEL TO STEEL CONNECTIONS SHALL BE ASTM A325-X BOLTS, INSTALLED TO A "SNUG TIGHT" CONDITION AND TORQUED TO 50 FT-LBS. M. STRUCTURAL STEEL SHOP DRAWINGS, PREPARED BY THE STEEL SUBCONTRACTORS, SHOWING COMPLETE DIMENSIONS, DETAILS, SIZES AND GRADES OF STEEL MEMBERS AND CONNECTIONS, TYPE AND NUMBER OF WELDS AND BOLTS SHALL BE SUBMITTED FOR APPROVAL PRIOR TO FABRICATION OF THE STEEL COMPONENTS. THE STRUCTURAL STEEL SUBCONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING, VERIFICATION AND COORDINATION OF DIMENSIONS AND DETAILS WITH THE STRUCTURAL AND OTHER PORTIONS OF THE CONTRACT DRAWINGS. N. CONCRETE STEEL REINFORCEMENT SHOP DRAWINGS SHALL BE SUBMITTED TO ENGINEER OF RECORD FOR REVIEW. M. THE STEEL FABRICATOR SHALL BE AISC CERTIFIED. L. ALL STRUCTURAL STEEL SHALL BE SHOP PRIMED WITH TWO COATS IN ACCORDANCE WITH AISC RECOMMENDATIONS. N. THE FOLLOWING VERIFICATIONS AND INSPECTIONS ARE REQUIRED FOR STRUCTURAL STEEL CONSTRUCTION: STRUCTURAL OBSERVATIONS: ENGINEER OF RECORD SHALL BE NOTIFIED 7 BUSINESS DAYS IN ADVANCE OF REQUIRED STRUCTURAL OBSERVATIONS. THE STRUCTURAL OBSERVATIONS REQUIRED ARE AS FOLLOWS: 1.) AS SOON AS FOUNDATION REINFORCEMENT IS IN PLACE, BUT PRIOR POURING CONCRETE. 2.) AS SOON AS SECOND FLOOR DECK AND MOMENT FRAMES ARE IN PLACE. 3.) AS SOON AS ROOF FRAMING AND DECKING IS IN PLACE, BUT PRIOR TO INSULATION INSTALLATION. J. BOLTS FOR WOOD TO WOOD OR WOOD TO STEEL SHALL BE ASTM A307 UNLESS NOTED OTHERWISE. PROVIDE STANDARD PLATE WASHERS UNDER ALL BOLT HEADS AND NUTS IN CONTACT WITH WOOD. INSTALL "FINGER TIGHT". DO NOT OVER TIGHTEN. 1.) MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS, NUTS AND WASHERS: a.) IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS. - PERIODIC b.) MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED. - PERIODIC 2.) INSPECTION OF HIGH STRENGTH BOLTING: a.) BEARING-TYPE CONNECTIONS. - PERIODIC b.) SLIP-CRITICAL CONNECTIONS. - CONTINUOUS 3.) MATERIAL VERIFICATION OF STRUCTURAL STEEL: a.) IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS. - PERIODIC b.) MANUFACTURER'S CERTIFIED MILL TEST REPORTS. - PERIODIC 4.) INSPECTION OF WELDING: a.) COMPLETE AND PARTIAL PENETRATION GROOVE WELDS. - CONTINUOUS b.) MULTI-PASS FILLET WELDS. - CONTINUOUS c.) SINGLE-PASS FILLET WELDS GREATER THAN 5/16" - CONTINUOUS d.) SINGLE-PASS FILLET WELDS LESS THAN OR EQUAL TO 5/16" - PERIODIC e.) FLOOR AND DECK WELDS. - PERIODIC A. WOOD FRAMING TO BE #2 DOUGLAS FIR OR BETTER UNLESS NOTED OTHERWISE ON THE PLANS. GLULAM MEMBERS ARE TO BE 24F-V4 UNLESS NOTED OTHERWISE ON THE PLANS. B. GLULAM BEAMS/RAFTERS TO BE ATTACHED TO STRUCTURE PER THE FRAMING PLANS AND STRUCTURAL DETAILS. C. PROVIDE SOLID BLOCKING BETWEEN RAFTERS AT ALL BEARING LOCATIONS. D. SHEATHING TO BE SPAN RATED PLYWOOD OR OSB FLOOR: 1 1/8" ROOF: 5/8" WALLS: 15/32" REVISIONS DATE DESCRIPTION No. JOB NO. SHEET DATE: DRAWN: SCALE: AS SHOWN SHEET TITLE: PROJECT: LOCATION: CLIENT: P.O. BOX 2646, CORVALLIS, OR 97339 STABILITY TEL.: (541)223-5360 FAX: (541)223-5278 777 NE 2ND ST. SUITE 280 ENGINEERING INC. S0.0 LW 16-0207 6/26/2017 6/26/2017 CONSTRUCTION NOTES CARLSON VEIT ARCHITECTS AVERY COMPLEX ADDITION 360 SW AVERY AVENUE CORVALLIS, OREGON 97333
9
Embed
S0 = 3/4" to 1" 1.) ... detailing reinforced concrete structures", aci 315 ... j. lap all bar reinforcing per aci 318.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
ANALYZED USING THE EQUIVALENTLATERAL FORCE PROCEDURE
S
S1
DS
Ss
SITE SOIL CLASS
SEISMIC DESIGN CATEGORY
EXPOSURE
B. STRUCTURE DESIGNED FOR THE FOLLOWING LOADS:
ROOF DEAD LOADS:
= D
= D
= 0.956
BASIC WIND SPEED (V) = 120 MPH
= B
IMPORTANCE FACTOR = I
GROUND SNOW LOAD = 25 PSF
ROOF LIVE LOADS:
= 0.473
= 0.713
MOMENT-RESISTING FRAME SYSTEM: R = 3.5STEEL ORDINARY MOMENT FRAMES
WIND LOADS:
SEISMIC DESIGN DATA:
BASIC STRUCTURAL & SEISMIC RESISTING SYSTEM:
A. STRUCTURE DESIGNED IN ACCORDANCE WITH THE 2014 OSSC.
FLAT ROOF SNOW LOAD = 25 PSF (MODIFIED FOR
DRIFTING AND UNBALANCED LOADS WHERE APPLICABLE)
C. IF ANY FIELD CONDITIONS PRECLUDE COMPLIANCE WITH THESE DRAWINGS AND/OR CONDITIONS SPECIFIED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY AND SHALL NOT PROCEED WITH THE AFFECTED WORK. THE CONTRACTOR SHALL VERIFY ALL BUILDING DIMENSIONS, DETAILS, AND CONDITIONS PRIOR TO START OF CONSTRUCTION THAT MAY BE IMPACTED BY VARIATIONS FROM THE CONDITIONS SHOWN HEREIN.
a. INSPECT FORM WORK AND PLACEMENT OF REINFORCEMENT
A. ALL CONCRETE WORK SHALL CONFORM WITH A.C.I. "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", ACI 318 - LATEST EDITION, AND "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES", ACI 315 - LATEST EDITION.
B. ALL CONCRETE FORM WORK WORK SHALL CONFORM WITH A.C.I. "RECOMMENDED PRACTICES FOR CONCRETE FORM WORK" - ACI 347.
C. ALL CONCRETE SHALL HAVE MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 3000 PSI. ALL STRUCTURAL CONCRETE SHALL CONFORM WITH A.C.I. "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" - ACI 301.
CEMENT SHALL BE PORTLAND CEMENT, TYPE I OR II, CONFORMING TO ASTM-C-150.
EXPANSION JOINTS SHALL BE 1/2" THICK ASPHALT IMPREGNATED FIBERBOARD
CURING COMPOUND SHALL BE CLEAR, CONFORMING TO ASTM C-309.
E. COLD WEATHER CONCRETE WORK, WHEN APPLICABLE, SHALL CONFORM TO ACI 306.
F. HOT WEATHER CONCRETE WORK, WHEN APPLICABLE, SHALL CONFORM TO ACI 305.
H. ALL BAR REINFORCING FOR CONCRETE TO CONFORM TO ASTM A615, GRADE 60. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185.
AIR-ENTRAINING ADMIXTURES SHALL CONFORM TO ASTM C-260.
I. CONCRETE ACCESSORIES TO BE ADEQUATE TO MAINTAIN REINFORCING ACCURATELY IN PLACE AND BE NON-CORROSIVE, NON-STAINING TYPE.
L. WELDED WIRE FABRIC SHALL HAVE MINIMUM END AND SIDE LAPS OF 1'-0".
J. LAP ALL BAR REINFORCING PER ACI 318. STAGGER SPLICES IN HORIZONTAL WALLS AND SLABS.
GENERAL NOTES:
SOIL NOTES:
CONCRETE NOTES:
FOR EACH DAY'S POUR FOR EACH TYPE OF CONCRETE.b. SLUMP PER ASTM C-143. ONE TEST AT POINT OF DISCHARGE
d. CONCRETE TEMPERATURE - TEST EACH TIME A SET OF COMPRESSION TEST IS TAKEN.
IN RESERVE FOR LATER TESTING IF REQUIRED.
ALL CONCRETE WORK, REINFORCING PLACEMENT, FORM WORK AND SHORING SHALL BE SPECIAL INSPECTED BY AN INDEPENDENT TESTING AGENCY RETAINED BY THE OWNER FOR THE FOLLOWING ITEMS:
CONCRETE SPECIAL INSPECTION REQUIREMENTS
D. CONTRACTOR SHALL SUBMIT MIX DESIGNS FOR APPROVAL. MIX DESIGN SHALL INDICATE 7 AND 28 DAYS STRENGTHS, CEMENT CONTENT, AIR CONTENT, WATER-CEMENT RATIO, AMOUNT OF FINE AND COARSE AGGREGATES AND ADMIXTURES. ALL EXTERIOR CONCRETE AND CONCRETE EXPOSED TO WEATHER SHALL BE AIR-ENTRAINED (4% TO 6%) UNLESS LOCAL STANDARDSARE OTHERWISE.
e. COMPRESSION TEST SPECIMEN PER ASTM C-31 (ONE SET OF 4 STANDARD CYLINDERS)
c. AIR CONTENT PER ASTM C-173 (VOLUMETRIC) OR ASTM C-231 (PRESSURE). ONE TEST FOR EACH DAY'S POUR FOR EACH TYPE OF CONCRETE.
g. TWO SPECIMENS TESTED AT 7 DAYS, ONE SPECIMENSTESTED AT 28 DAYS, AND ONE SPECIMEN RETAINED
h. EPOXIED ALL THREAD AND REBAR DOWELS; AND EXPANSION ANCHORS INTO CONCRETE.
f. COMPRESSION STRENGTH TEST PER ASTM C-39. ONE SET FOR EACH DAY'S POUR FOR EACH TYPE OF CONCRETEPLUS ADDITIONAL SETS FOR EACH 100 cy OVER AND ABOVE THE FIRST 100 cy.
M. HILTI HY 200 OR SIMPSON SET XP EPOXY ADHESIVE IS REQUIRED FOR ALL REBAR DOWELS OR ALL THREAD DRILLED AND EPOXIED INTO CONCRETE.
A. SOIL BEARING CAPACITY USED IN DESIGN OF NEW FOUNDATION: 1500 PSF. ALL FOOTINGS TO BEAR A MINIMUM OF 18" BELOW FINISHED GRADE ON UNDISTURBED SOIL OR APPROVED STRUCTURAL FILL. PROVIDE AND INSTALL STRUCTURAL FILL AS NECESSARY. IF UNSUITABLE SOILS ARE ENCOUNTERED, OR IF ROCK IS ENCOUNTERED IN THE AREA OF THE PROPOSED BOTTOM OF FOOTING, NOTIFY THE ENGINEER IMMEDIATELY.
B. THE GEOTECHNICAL ENGINEER SHALL OBSERVE AND APPROVE SUBGRADE SOILS PRIOR TO THE PLACEMENT OF STRUCTURALFILL OR FOOTING FORMS.
NOTE: B-E ARE NOT APPLICABLE IF GEOTECHNICAL REPORT IS NOT REQUIRED BY THE BUILDING OFFICAL
D. PLACEMENT AND COMPACTION OF STRUCTURAL FILL SHALL BE OBSERVED BY THE GEOTECHNICAL ENGINEER AND/OR TEST RESULTSBY A QUALIFIED TESTING AGENCY.
E. COMPLY WITH SPECIFICATIONS AND GEOTECHNICAL REPORT RECOMMENDATIONS FOR ALL FILLS AND EXCAVATIONS.
C. STRUCTURAL FILL MATERIAL TYPE AND SOURCE SHALL BE APPROVED BY GEOTECHNICAL ENGINEER PRIOR TO INSTALLATION.
ROOF (TOTAL) = 20 PSF
G. SCREED SLABS AT GRADE LEVEL, MAINTAINING SURFACE FLATNESS OF MAXIMUM 1/4" IN 10'-0".
C. ALL STEEL TUBE COLUMNS SHALL CONFORM TO ASTM A500, GRADE B.
K. ALL BOLTS, NUTS, AND WASHERS SHALL BE IN ACCORDANCE WITH THE LATEST SPECIFICATIONS APPROVED BY THE RESEARCH COUNCIL ON RIVETED AND BOLTED STRUCTURAL JOINTS.
A. STEEL SHALL CONFORM TO THE "SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, ALLOWABLE STRESS DESIGN AND PLASTIC DESIGN" LATEST EDITION, OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION.
H. ALL WELDS SHALL CONFORM TO THE "STRUCTURAL WELDING CODE (STEEL)," AWS D1.1, LATEST EDITION.
i) COMPLETE-JOINT-PENETRATION WELDS (CJP) ARE TO BE CONSTRUCTED PER THE WELDERS PREFERENCE AND PER ANSI/AISC 341-05, 11.2a.
a) BACKING IS TO BE REMOVED AND BACKWELDED WITH A 5/16" FILLET WELD.
b) WHERE WELD ACCESS HOLES ARE PROVIDED, THEY WILL CONFORM TO AISC SPECIFICATION.
G. ALL ANCHOR RODS SHALL CONFORM TO ASTM F1554 GRADE 36.
F. ALL HEADED STUDS SHALL CONFORM TO ASTM A-108, GRADE 1015 OR 1020.
E. ALL MISCELLANEOUS STRUCTURAL STEEL SHALL BE ASTM A36.
B. STRUCTURAL STEEL SHALL CONFORM TO ASTM A992, EXCEPT AS MODIFIED BELOW.
D. ALL STEEL PIPE COLUMNS SHALL CONFORM TO ASTM A53, TYPE E OR S, GRADE B, OR ASTM A501.
STRUCTURAL STEEL NOTES:
WOOD GENERAL NOTES:
STRUCTURAL OBSERVATIONS:
STRUCTURAL STEEL SPECIAL INSPECTION REQUIREMENTS
I. BOLTS FOR STEEL TO STEEL CONNECTIONS SHALL BE ASTM A325-X BOLTS, INSTALLED TO A "SNUG TIGHT" CONDITION AND TORQUED TO 50 FT-LBS.
M. STRUCTURAL STEEL SHOP DRAWINGS, PREPARED BY THE STEEL SUBCONTRACTORS, SHOWING COMPLETE DIMENSIONS, DETAILS, SIZES AND GRADES OF STEEL MEMBERS AND CONNECTIONS, TYPE AND NUMBER OF WELDS AND BOLTS SHALL BE SUBMITTED FOR APPROVAL PRIOR TO FABRICATION OF THE STEEL COMPONENTS. THE STRUCTURAL STEEL SUBCONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING, VERIFICATION AND COORDINATION OF DIMENSIONS AND DETAILS WITH THE STRUCTURAL AND OTHER PORTIONS OF THE CONTRACT DRAWINGS.
N. CONCRETE STEEL REINFORCEMENT SHOP DRAWINGS SHALL BESUBMITTED TO ENGINEER OF RECORD FOR REVIEW.
M. THE STEEL FABRICATOR SHALL BE AISC CERTIFIED.
L. ALL STRUCTURAL STEEL SHALL BE SHOP PRIMED WITH TWO COATS IN ACCORDANCE WITH AISC RECOMMENDATIONS.
N. THE FOLLOWING VERIFICATIONS AND INSPECTIONS ARE REQUIRED FOR STRUCTURAL STEEL CONSTRUCTION:
STRUCTURAL OBSERVATIONS:
ENGINEER OF RECORD SHALL BE NOTIFIED 7 BUSINESS DAYS IN ADVANCE OF REQUIRED STRUCTURAL OBSERVATIONS. THE STRUCTURAL OBSERVATIONS REQUIREDARE AS FOLLOWS:
1.) AS SOON AS FOUNDATION REINFORCEMENT IS IN PLACE, BUT PRIOR POURING CONCRETE.2.) AS SOON AS SECOND FLOOR DECK AND MOMENT FRAMES ARE IN PLACE.3.) AS SOON AS ROOF FRAMING AND DECKING IS IN PLACE, BUT PRIOR TO INSULATION INSTALLATION.
J. BOLTS FOR WOOD TO WOOD OR WOOD TO STEEL SHALL BE ASTM A307 UNLESS NOTED OTHERWISE. PROVIDE STANDARD PLATE WASHERS UNDER ALL BOLT HEADS AND NUTS IN CONTACT WITH WOOD. INSTALL "FINGER TIGHT". DO NOT OVER TIGHTEN.
1.) MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS, NUTS ANDWASHERS: a.) IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS. - PERIODIC b.) MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED. - PERIODIC
2.) INSPECTION OF HIGH STRENGTH BOLTING: a.) BEARING-TYPE CONNECTIONS. - PERIODIC b.) SLIP-CRITICAL CONNECTIONS. - CONTINUOUS
3.) MATERIAL VERIFICATION OF STRUCTURAL STEEL: a.) IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS. - PERIODIC b.) MANUFACTURER'S CERTIFIED MILL TEST REPORTS. - PERIODIC
4.) INSPECTION OF WELDING: a.) COMPLETE AND PARTIAL PENETRATION GROOVE WELDS. - CONTINUOUS b.) MULTI-PASS FILLET WELDS. - CONTINUOUS c.) SINGLE-PASS FILLET WELDS GREATER THAN 5/16" - CONTINUOUS d.) SINGLE-PASS FILLET WELDS LESS THAN OR EQUAL TO 5/16" - PERIODIC e.) FLOOR AND DECK WELDS. - PERIODIC
A. WOOD FRAMING TO BE #2 DOUGLAS FIR OR BETTER UNLESS NOTED OTHERWISE ON THE PLANS. GLULAM MEMBERS ARE TO BE 24F-V4 UNLESS NOTED OTHERWISE ON THE PLANS.B. GLULAM BEAMS/RAFTERS TO BE ATTACHED TO STRUCTURE PER THE FRAMING PLANS AND STRUCTURAL DETAILS.C. PROVIDE SOLID BLOCKING BETWEEN RAFTERS AT ALL BEARING LOCATIONS.
D. SHEATHING TO BE SPAN RATED PLYWOOD OR OSB FLOOR: 1 1/8" ROOF: 5/8" WALLS: 15/32"
RE
VIS
ION
S
DA
TE
DE
SC
RIP
TIO
NN
o.
JOB NO.
SHEET
DATE:
DRAWN:
SCALE: AS SHOWN
SH
EE
T T
ITL
E:
PR
OJE
CT
:
LO
CA
TIO
N:
CL
IEN
T:
P.O
. B
OX
26
46
, C
OR
VA
LL
IS, O
R 9
73
39
ST
AB
ILIT
Y
TE
L.: (
54
1)2
23
-53
60
F
AX
: (5
41
)22
3-5
27
8
77
7 N
E 2
ND
ST
. S
UIT
E 2
80
EN
GIN
EE
RIN
GIN
C.
S0.0
LW
16-0207
6/26/2017
6/26/2017
CO
NS
TR
UC
TIO
N N
OT
ES
CA
RL
SO
N V
EIT
AR
CH
ITE
CT
S
AV
ER
Y C
OM
PL
EX
AD
DIT
ION
36
0 S
W A
VE
RY
AV
EN
UE
CO
RV
AL
LIS
, O
RE
GO
N 9
73
33
FLOOR FRAMING PLANFOUNDATION PLAN
SCALE: 1/8" = 1'-0"
SCALE: 1/8" = 1'-0" B
A
G
E
E
E
EEF
F
F
F
F
F
E F
J
H
G
J
D
D
E
F
J
I
I
E
E
E
E
E
E
E
J
E F
A
G
B
D
J
D
D
B
A
S1.0
S4.0
S5.3
S5.0
S5.0
S5.0
S5.0S5.0S5.2
S5.2
S5.2
S5.2
S5.2
S5.2
S5.0 S5.2
S5.2
S5.2
S5.2
S5.2
S5.3
S5.3
S5.3
S5.3
S5.2
S5.1
S5.2SIM
S5.0
S5.0
S5.0
S5.0
S5.0
S5.0
S5.0
S5.2
S5.0 S5.2
S4.0
S5.1
S4.0
S5.1
S5.1
S5.2
S5.1
S4.0
S1.0
A A
1 1
2 2
3 3
4 4
5 5
6 6
7 7
7.57.5
8 8
9 9
B BC C DD EE F F GG
ALL HEADERS4X12 U.N.O.
ALL JOISTS 18" TJI 560 @ 16" O.C. U.N.O.
B
B
G
B
B
AA
A
A
A
A
A
A
AA
A
A
A
C
C
D
F
C
E
E
E
C
C
A
A
B
B
C
D
E
F
G
- 9'-0" X 9'-0" X 18" FTG W/ (2) LAYERS OF (15) #5 BARS E/W
- W8X35 STEEL POST
- 6'-0" X 6'-0" X 16" FTG W/ (2) LAYERS OF (11) #5 BARS E/W
- 5" X 5" X 3/8" HSS STEEL POST
- 5'-0" X 5'-0" X 16" FTG W/ (2) LAYERS OF (9) #5 BARS E/W
- 3'-6" X 3'-6" X 16" FTG W/ (2) LAYERS OF (7) #5 BARS E/W
- 3'-0" X 3'-0" X 16" FTG W/ (2) LAYERS OF (4) #5 BARS E/W
- 6'-6" X 6'-6" X 16" FTG W/ (2) LAYERS OF (12) #5 BARS E/W
- 6'-0" X 6'-0" X 24" FTG W/ (2) LAYERS OF (11) #5 BARS E/W
MIN. 3" X 3" X .229PLATE WASHER. EDGEMUST BE WITHIN 1/2" OF EDGE OF SILL PLATE.NOTE: A 4 1/2" PLATEMAY BE USED W/ THEANCHOR BOLT CENTEREDIN THE SILL PLATE FOR EASEOF CONSTRUCTION.
ATTACH P.T. 2 X 12 TO SLAB W/ (2) ROWSOF L.V.F.s @ 12" O.C.
3/16"
RE
VIS
ION
S
DA
TE
DE
SC
RIP
TIO
NN
o.
JOB NO.
SHEET
DATE:
DRAWN:
SCALE: AS SHOWN
SH
EE
T T
ITL
E:
PR
OJE
CT
:
LO
CA
TIO
N:
CL
IEN
T:
P.O
. B
OX
26
46
, C
OR
VA
LL
IS, O
R 9
73
39
ST
AB
ILIT
Y
TE
L.: (
54
1)2
23
-53
60
F
AX
: (5
41
)22
3-5
27
8
77
7 N
E 2
ND
ST
. S
UIT
E 2
80
EN
GIN
EE
RIN
GIN
C.
S5.2
LW
16-0207
6/26/2017
6/26/2017
DE
TA
ILS
CA
RL
SO
N V
EIT
AR
CH
ITE
CT
S
AV
ER
Y C
OM
PL
EX
AD
DIT
ION
36
0 S
W A
VE
RY
AV
EN
UE
CO
RV
AL
LIS
, O
RE
GO
N 9
73
33
FLOOR FRAMINGNAIL 3/4" X 18" X TRUSS HEIGHT PLYWOOD GUSSETTO EA SIDE OF TRUSS W/8d NAILS @ 4" O.C.
NEW VERTICAL2X CHORD
HU212HANGERSLOPED
2X LEDGER
2X12 RAFTER
EXISTING TRUSS
STAIR 2 - FIRST FLOOR PLAN STAIR 2 - SECOND FLOOR PLAN
SCALE: 1" = 1'-0"
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"I
G H
S5.2
S5.2 S5.2
BI
A
A G
G
S5.3S5.2
S5.3
S5.3 S5.3
S5.3
C12X20.7 (TYP.)
L3X3X5/16 TO SUPPORTDECKING (TYP.) L3X3X5/16 (TYP.)
C12X20.7 (TYP.)
L3X3X5/16TO SUPPORTDECKING
STAIR STRINGER
1/2" HILTI KWIK BOLT(MIN EMBED = 3 1/4")
4" LONG L3X3X1/4" EACH STRINGER
CONTINUOUS FOOTINGSEE FOUNDATION PLAN
STAIR ANCHORAGE DETAIL
COPE BEAMS PERAISC STANDARDSSTIFFENER PLATE
PER TABLE
SEE PLAN FORBEAM SIZES
1/4
THICKNESS PLUS UPTO 1/8"
1/4
1/4"
1/4"
1/4"
3/16"
1/4
1/4
TYP.
1 1/2"
3" TYP.
1 1/2" MIN.
"h"
L3 1/2 x 3 x 3/8
COPE PER AISC COPE PER AISC COPE PER AISC
WF BEAMSEE PLAN
WF BEAMSEE PLAN
FRAMED BEAMSEE PLAN
FRAMED BEAMSEE PLAN
FRAMED BEAMSEE PLAN
ALT. BOLTED/WELDED ALL BOLTEDBOLTED/WELDED
1" RETURN AT TOP
(3)SIDES
3 SIDES
(3)SIDES
SUPPORTEDBEAM
3/4" DIA.A325NBOLTS
STIFFENERPLATE
t h min
W27
W24
W21
W18
W16
W12
W10
3/8"
3/8"
3/8"
3/8"
3/8"
1/4"
1/4"
FULL HT.
FULL HT.
FULL HT.
FULL HT.
FULL HT.
9"
7"
8
7
6
5
4
3
2
1. ALL BOLTS TO BE ASTM A325N, INSTALLED TO SNUG-TIGHT CONDITION AND TIGHTENED PER TURN-OF-THE-NUT METHOD.
2. TYPICAL BOLT SPACING = 3" ON CENTER (UNLESS NOTED OTHERWISE)
3. BOLTS TO BE INSTALLED IN STANDARD HOLES. WHERE BOTH ENDS OF A PIECE ARE TO BE BOLTED, ONE END MAY HAVE BOLTS INSTALLED USING HORIZONTAL SHORT SLOTTED HOLES IN EITHER THE BEAM WEB OR SHEAR PLATE/ANGLE (BUT NOT BOTH) PER AISC SPECIFICATIONS.