Top Banner
17

S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression. Gas Driven: Can be set as Permanent, or Temporary Electric Driven:

Jan 11, 2016

Download

Documents

Alaina Cross
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:
Page 2: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Gas Gathering

Two typical types of compression.

Gas Driven: Can be set as Permanent, or Temporary

Electric Driven: Normally a Permanent Installation

Page 3: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Gas Gathering

Temporary Gas Compression

Page 4: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Temporary Gas Driven Compression

Gas Gathering

Page 5: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Gas Gathering

Rig Counts: North Parachute - 10 Rigs Eureka - 2 Rigs

Permanent Indoor Gas Compression

Page 6: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Compressor Gas Cooler Fans (Air Exchangers)

Air exchanger fan blades are one of the biggest source of noise from the fan tip speeds.

EnCana is looking at having bigger exchanger boxes installed on new applications, to be able to slow the fan tip speeds down

One new innovation is the new “Whisper Tip” fan blades. These new fan blades cut the sound level in half.

Gas Gathering

Page 7: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Gas Gathering

Different Types of Coolers – Vertical and Horizontal

Permanent Indoor Gas Compression

Page 8: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Gas Gathering

Permanent Gas Compression

Horizontal Coolers with Extensions to Mitigate Sound

Page 9: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Gas Gathering

Permanent Gas Compression

3 Horizontal Coolers with Extensions to Mitigate Sound

Page 10: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Gas Gathering

Electric Compression Electric driven compression has no

exhaust, but requires cooling of the gas with horizontal air fan exchanger.

Limitations are power supply requirements and installation costs

Page 11: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Gas Gathering

7500 Hp Electric Compression

Page 12: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Gas Gathering

1500 Hp Electric Refrigeration Compression

Page 13: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Gas Gathering

EnCana uses two different muffler manufacturers.

Power Therm---The Power Therm’s are a “Critical Grade” muffler, which is a reduction of 29-35 Dba.

Miratech---The Miratech’s are listed as a “Hospital Grade”, which is a reduction of 30-35 Dba.

Muffler stacks are normally cut on a bevel to direct sound to the most desirable direction.

Page 14: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Gas Gathering

Typical Muffler Design.

Most have a Catalyst section for emission control, and can either lay

horizontal, or stand vertical

Page 15: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

What is Encana doing to reduce compressor noise

EnCana is currently exploring several new technologies for sound control.

EnCana is using third party sound suppression experts to help us better understand how sound travels, and the different sound frequencies

Gas Gathering

Page 16: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Gas Gathering

Page 17: S OUTH R OCKIES B USINESS U NIT Gas Gathering n Two typical types of compression.  Gas Driven: Can be set as Permanent, or Temporary  Electric Driven:

SOUTH ROCKIES BUSINESS UNIT

Gas Gathering