This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
SPECIFICATIONS
RX12AFT-ISFlush Mount Lift Rack
Site Specifications
Substructure Requirements Refer to 6470-T for full details
Power Requirements 208-230 VAC, single phase power, 26 Amp
Air Supply Requirements 90-150 PSI (6.2-10.3 bar)Jacks require 125 PSI (8.6 bar) for full capacity
Minimum Concrete Spec. 3 in. (76 mm) thick, 3000 PSI (20,700 kPA) ratingMaximum Floor Slope 2 in. (51mm) over 126 in. (3200 mm)
Product SpecificationsMax. Vehicle Weight 12,000 lbs. (5443 kg)
Max. Wheelbase General Service 180 in. (4572 mm) Two-Wheel Alignment 175 in. (4445 mm) Four-Wheel Alignment 158 in. (4013 mm)Alignment Height All lock positionsMin. Four-Wheel Alignment 88 in. (2235 mm)Lifting Speed 55 seconds Lowering Speed 25 seconds
Dimensions shown are for finished pit. Tile thickness (if applicable) must be considered before pouring pit.
*Non-standard positioning of control console is limited to a maximum space between console and rack of 6 feet (1829 mm) at the approach ramp end and 18 feet (5486 mm) at the turnplate end. Additional threshold and perhaps hydraulic hoses will be required (refer to Installation Instruction for details).
! WARNING
!WARNING
!WARNING
!WARNING
DRAINLOCATED
INCENTEROF PIT
SLOPEPIT
FLOORTOWARD
DRAIN(1/2)
CONSOLE CONDUIT DETAIL
92 1/2"(2350 mm)
! WARNINGSTAY BEHINDYELLOW LINE
WHEN THELIFT MOVES.
128-978-2
DECAL 128-978-2
OPTIONAL CONSOLE LOCATION
(4 places on edging and 2 places on lift)
41 3/8"(1051 mm)
141 3/4"(3600 mm)
14"(356 mm)
APPROX. 2" (51 mm) TYPICAL
14"(356 mm)
5"(127 mm)
5"(127 mm)
14"X 5"CUTOUT(4 places)
ANGLE AROUND PIT PERIMETER:- not around
- painted safety yellow- not supplied by Hunter
14"X 5"cutouts
16"(406mm)
22"(559 mm)
6" MIN.*152 mm( )
OPTIONAL 1 ½ IN. DIA. CONDUITFOR COMMUNICATION CABLE
TO ALIGNMENT CONSOLE
HAWKEYE SERIES SENSORSAND PRONTO SYSTEMS HAVE
SPACE REQUIREMENTS INFRONT OF LIFT THAT MUST BEMET, REFER TO APPROPRIATE
SITE REQUIREMENTS.
ENTIRE PIT(BOTTOM AND WALLS)
MUST BE HARDTROWEL FINISH
FILLER PLATE51-2308-1(4 places)
(placed over14"X 5"cutout)
34 3/4"(883 mm) EXTENDER
PLATES51-2464-1-PPP
ANDRAMPS
147-141-1-PPP
RAMPS147-141-1-PPP
66 3/4"(1695 mm)
228 3/8"(5801 mm)
30 3/4"(781 mm)
VEHICLE APPROACH
* LONGER VEHICLES WILL NEED TO BE SERVICED WITH BAY DOOR OPEN. TOACCOMMODATE MOST VEHICLES, INCREASE SPACE BEHIND PIT TO ( ) ORGREATER.
39" 991 mm** SITES WITH D.R.W. TRUCKTRAFFIC SHOULD USE 20" MIN.CONSOLE TO PIT DISTANCE.
**15" TO 41"
(381 TO 1041 mm)
45
6" MIN.RADIUS CONDUIT
EXIT FLUSHWITH
PIT FLOOR
ROUTE 4" MIN DIAMETERCONDUIT OR EQUIVALENTCLOSED CHANNEL FROMPIT FLOOR TO BASE OF