www.baumer.com RP2N Compact pressure switch 2014-04-15 Design and specifications subject to change without notice Page 1 / 4 Data sheet A32.01 RP2N Compact pressure switch Main Features Applications Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Resistant to accidental overpressure Light weight Pneumatic appliances Power generation safety equipment Water treatment Valve and compressor control Technical Data Pressure range 0 ... 1 bar to 0 ... 100 bar Temperature Process : -40 ... +150°C Ambient : -30 ... +70°C Storage : -40 ... +70°C Repeatability ± 1% F.S. @ constant pressure cycle CE conformity Low Voltage Directive LVD 2006/95/EC Pressure Equipment Directive PED 97/23/EC Protection rating IP 66 (EN 60529) Process Connection Stainless steel 1.4404 (316L) Diaphragm Stainless steel 1.4404 (316L) Scale Internal graduated scale Weight 0.960 kg Body Zamak black painting Housing Plastic PA6, blue Mounting Wall mounting 2 x M5 screws Options Customer specific set point adjustment Code SETP Oxygen application Code 0765 Mounting on 2" pipe Code 0407 Stainless steel tag plate and wire Code 9941 Lead seal of the housing Code 8990 Ground connection Via internal terminal block Electrical connection Via internal terminal block with cable gland for Ø 5.5 to 8.5 mm Electrical function See ordering code details on page 4 Adjustment Internal adjustment possible for set point and dead band
8
Embed
RP2N - Hidraulica Olagorta, S. L. · Membrana acero inoxidable 1.4404 (AISI 316 L) RP2E--Aluminio AS 10 G revestido pin-tura epoxy 2 tornillos acero inoxidable CHC M6x16 Sobre borne
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
www.baumer.com
RP2NCompact pressure switch
2014
-04-
15
D
esig
n an
d sp
ecifi
catio
ns s
ubje
ct to
cha
nge
with
out n
otic
e
Page 1 / 4Data sheet A32.01
RP2NCompact pressure switch
Main Features
Applications
�� Excellent repeatability�� Dead band adjustment for regulation�� Fix dead band for control and alarm�� Resistant to accidental overpressure�� Light weight
�� Pneumatic appliances�� Power generation safety equipment�� Water treatment�� Valve and compressor control
Technical Data
Pressure range 0 ... 1 bar to 0 ... 100 barTemperature Process : -40 ... +150°C
1) The value of the dead band is depending on the value of the set point.This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For adjustable dead band the lower value corresponds to the dead band spring totally released and the higher corresponds to the dead band spring fully tensed . For other set points the dead band value can be calculated by linear interpolation between the values at 10% and 90%.
A flexible sensing element actuates a microswitch by means of a piston. The set point is adjusted by means of a compressible spring installed in opposition.
Set point and reset point must be between 10% and 90% of the selec-ted scale.
Standard factory adjustment Setpoint at 50% of the scale on falling pressure
Customer specific factory adjustment (option SETP)The following specifications have to be given with the order:• Setpoint value• Adjustment on falling or raising pressure• Dead band value when using an adjustable dead band switch
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
www.baumer.com
68
27 / 2 plats
2 x 5,5
97
73,5
98
33
G1/2 33
68
27 / 2 plats
2 x 5,5
97
73,5
98
33
G1/2 33
COM
NO
NC
RP2NCompact pressure switch
2014
-04-
15
D
esig
n an
d sp
ecifi
catio
ns s
ubje
ct to
cha
nge
with
out n
otic
e
Page 3 / 4Data sheet A32.01
Dimensions (mm)
Electrical connections
Terminal block
Blue
Red
White
Yellow / green
Micro switch
Micro switches characteristics
Switch code R L M N P
Type Adjustabledead band
Fixed dead band
Standard Gold contact Tropicalized Ultra sensitive
6 Vdc 0.4 ... 20 A N/A 10 ... 50 mA 0.1 ... 8 A 0.4 ... 4 A
12 Vdc 0.4 ... 20 A N/A 10 ... 50 mA 0.1 ... 8 A 0.4 ... 4 A
24 Vdc 0.4 ... 5 A N/A 10 ... 50 mA 0.1 ... 8 A 0.4 ... 4 A
30 Vdc 0.4 ... 5 A N/A 10 ... 50 mA 0.1 ... 8 A 0.4 ... 2 A
48 Vdc 0.4 ... 5 A N/A 10 ... 50 mA 0.1 ... 8 A N/A
110 Vdc 0.2 ... 0.5 A N/A 10 ... 50 mA N/A N/A
220 Vdc 0.1 ... 0.25 A N/A 10 ... 50 mA N/A N/A
115 Vac 0.4 ... 20 A 0.4 ... 15 A 10 ... 50 mA 0.1 ... 10 A N/A
250 Vac 0.2 ... 20 A 0.2 ... 15 A N/A 0.1 ... 10 A N/A
Dielectric rigidity between contacts and ground 2000 V 2000 V 2000 V 2000 V 1000 V
flats
www.baumer.com
RP2NCompact pressure switch
2014
-04-
15
D
esig
n an
d sp
ecifi
catio
ns s
ubje
ct to
cha
nge
with
out n
otic
e
Page 4 / 4Data sheet A32.01
Ordering details RP2N
RP2 – . xx /ModelCompact pressure switch RP2
–ApprovalsStandard version without ATEX approval N
Type of micro switches1 SPDT standard change over switch L1 SPDT gold contact change over switch M1 SPDT tropicalized change over switch N1 SPDT hermetically ultra sensitive change over switch P1 SPDT change over switch with adjustable dead band R
Options to be added behind the / (see example below) /
Ordering example with options
Compact pressure switch
Without ATEX approval
1 SPDT standard change over switch
Process connection G1/2 male
Pressure range 0 ... 10 bar over pressure max. 40 bar
Option : Oxygen applicationOption : Mounting on 2" pipe
Option : Stainless steel tag plate and wire
RP2 – N L . 3 53 / 0765 _ 0407 _ 9941
Placa interna graduada
G 1/2
Membrana de acero inoxidable 1.4404 (AISI 316 L)
PresostatosVersión estándar RP2N
seguridad intrínseca RP2Ycaja a prueba de explosón RP2E
Estos presostatos mantienen una presión constante en torno a un valor de ajuste seleccionado “acción de regulación”, o disparan un sistema de alarma o seguridad cuando la presión que se va a controlar alcanza un umbral crítico “acción de seguridad”.
• Todos los ambientes industriales• Reducidas dimensiones• Buena resistencia a las vibraciones• Sobrepresión admisible• Versión seguridad intrínseca (RP2Y): EEx ia II C T6, certificado L.C.I.E. n°94.C 6052 X.• Versión ADF (RP2E): EEx d II C T6, N° de certificado L.C.I.E. 93.C6145 X (CENELEC).
ImportanteEl funcionamiento debe situarse imperativemente entre 10% y 90% de la escala seleccionada. Los valores de desviación de los cuadros que figuran a continuación están definidos bajo estas condiciones.Todo circuito pulsatorio deberá ser equipado de amortiguadores de pulsaciones. En fluidos cargados o corrosivos: montaje de los separadores apropiados.La versión RP2Y sólo puede ser utilizada en circuitos de seguridad intrínseca.
06/0
1 -
N°
3020
07 E
CONSTRUCCIÓN
Cuerpo
Caja
Fijación mural
Toma de tierra
Conexióneléctrica
Escalagraduada
Conexión presión
Elemento de medida
RP2N - RP2Y
Zamac cincado negro
Poliamida PA6, azul
2 tornillos M5
Sobre borne interno
Sobre borne internocon P.E.9 para cable
Ø 5,5 a 8,5 mm
CONSTRUCCIÓN
Tapa
Base
Caja
Fijación mural
Toma de tierra
Conexióneléctrica
Escalagraduada
Conexión presión
Elemento de medida
Placa interna graduada
G 1/2
Membrana acero inoxidable 1.4404 (AISI 316 L)
RP2E
-
-
Aluminio AS 10 G revestido pin-tura epoxy
2 tornillos acero inoxidable CHC M6x16
Sobre borne interno o externo
Sobre borne interno con P.E. con-forme EEx d II C T6 para cable Ø
7 a 12 mm
Características (20°C)
Un elemento deformable, membrana, acciona un micro interruptor por medio de un pistón. El ajuste de la consigna se obtiene por medio de un resorte compresible, montado en oposición.
P
Principio de funcionamiento
Se reserva el derecho de hacer modificationes sin previo aviso
Características (20°C)
Rangos de regulación
Desviaciones mínimas Según el tipo de micro interruptor (ver cuadro).
Índice de protección IF 65 según IEC 529 (NFC 20.010), NF EN 60529.
Masa: RP2N = 0,960 kg; RP2E = 1.800 kg RP2Y = 0,960 kg
RP2N (versión estándar) – RP2Y (seguridad intrínseca) RP2E (caja a prueba de explosión)
PRESTACIONESFluidos Todos los fluidos compatibles con el elemento de medida, de-40°C a +150°C.
Temperatura ambiente de funcionamiento De -30 °C a +70°C.
Temperatura de almacenamiento De -50°C a +70°C.
Reproductibilidad ±2% del E.M.
Esquemas de conexión
1 2 3
voirnota
rouge = commun
blanc
bleuCâblageinterneeffectuépar nossoins
Câblagepar vossoins bornier interne
interface raccordement installation
vers utilisation
Nota : la flêche indique le sens de travail à la montée de pression ou de température
NF NOCableado interno efec-
tuado por nuestra cuenta
Cableado por cuentadel cliente placa de bornes internos
interfase conexión instalación
la flecha indica el sentido de trabajo cuando aumentala presión o la temperatura.
Nota:
hacia utilización
rojo = común
blancover nota
Escala Código
P. máx. DESVIACIÓN MÍN.-MÁX. REGULABLEDESVIACIÓN MÁX. FIJA
No codificadas (indicar en lenguaje claro después de la codificación) : • Etiqueta de identificación de acero inoxidable • Limpieza para oxígeno • Regulación de las valores de consigna • Conector de fijación en tubo 2" • Entrada de conducto ADF (RP2E únicamente) : 1/2 NPT hembra, M20 x 1,5 hembra, 3/4 NPT hembra.
Las opciones no codificadas deben indicarse en lenguaje claro después de la codificación*
*
Se
rese
rva
el d
erec
ho d
e ha
cer
mod
ifica
tion
es s
in p
revi
o av
iso
Familia: Presostatos R
Tipo:
Sigla comercial P2 P2
Tipo de protección:
Estándar N
Seguridad intrínseca Y
A prueba de explosión E
Tipo de micro interruptor: Banda muerta fija, 10 A/250 V estándar (1 x SPDT) L Banda muerta fija, 2 x SPDT (solo RP2E) U Banda muerta fija, contacto oro 50 mA/250V~ M Banda muerta fija, hermético, muy sensible 1 A/250 V~ P Banda muerta fija, tropicalizado 5A/250V~ N Banda muerta ajustable 10 A/250 V~ R
Conexión hidráulica:
G 1/2 macho (versión estándar) 3 1/2 NPT macho 6 1/4 NPT hembra 8 1/2 NPT hembra N