RoSS Plate Freeze-Thaw Unit Freeze-Thaw Your Drug Substance ■ In various sizes of Allegro™ single-use biocontainer bags ■ Fully automated and controlled ■ With highest possible speed and accuracy ■ For best product stability results ■ From small-scale to large-scale ■ Fully scalable up to 232 L RoSS.pFTU is a plate-based freeze-thaw unit for any scale and batch size. Based on plates, the freezing and thawing time is controlled and rapid. BIOTECH RoSS.pFTU u Large-Scale USD3435a 1 G 3 /4 in. water connection PT 100 inlet PT 100 outlet Signal tower acoustic signal red light amber light green light Detail A outlet inlet cooling water connection Main power connection Connection plugs to chamber 1001 mm (39.4 in.) 1254 mm (49.4 in.) 1329 mm (52.3 in.) 170 mm (6.7 in.) 1900 mm (74.8 in.) 2900 mm (114.2 in.) 426 mm (16.8 in.) 778 mm (30.6 in.) 2110 mm (83.1 in.) 2255 mm (88.8 in.) 600 mm (23.6 in.) 265 mm (10.5 in.) 2308 mm (90.9 in.) 2748 mm (108.2 in.)
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
RoSS Plate Freeze-Thaw Unit
Freeze-Thaw Your Drug Substance ■ In various sizes of Allegro™ single-use biocontainer bags
■ Fully automated and controlled
■ With highest possible speed and accuracy
■ For best product stability results
■ From small-scale to large-scale
■ Fully scalable up to 232 L
RoSS.pFTU is a plate-based freeze-thaw unit for any scale and batch size. Based on plates, the freezing and thawing time is controlled and rapid.
BIOTECH
RoSS.pFTUu Large-Scale
USD3435a
1
G 3/4 in. water connection
PT 100 inlet
PT 100 outlet
Signal toweracoustic signalred lightamber lightgreen light
Detail A
outlet inlet
cooling water connection
Main power connection
Connection plugs to chamber
1001 mm (39.4 in.)
1254 mm (49.4 in.)
1329 mm (52.3 in.)
170
mm
(6.7
in.)
1900 mm (74.8 in.)
2900 mm (114.2 in.)
426
mm
(16.
8 in
.)
778 mm (30.6 in.)
2110
mm
(83.
1 in
.)
2255
mm
(88.
8 in
.)
600 mm(23.6 in.)
265 mm (10.5 in.)
2308 mm (90.9 in.)
2748
mm
(108
.2 in
.)
Table 1Specification for RoSS_pFTU system when used with Allegro single-use biocontainer bags
Attribute Specification
Allegro single-use biocontainer bags Allegro 0.5 L - 20 L nominal filling volume
Full load Up to 232 L (depending on biocontainer bag type and size)
Partial fill Any volume possible
Minimum temperature -80 ºC
Cooling media (inside freezing plates) Silicone thermo-oil
Cooling option temperature control unit (TCU) Water or external chiller
Sound pressure level ± 4 dB (A) 64 dB (A)
TCU tap water consumption for cooling Up to 790 L/h* at 15 - 20 °C or via external chiller (available on demand)
Electricity EU/CN: 400 V, 3 - 40 A, 50 Hz, US: 480 V, 3 - 35 A, 60 Hz
Minimum/maximum ambient temperature +15 to +25 °C
Maximum relative humidity 75%
Dimensions (W x D x H) Minimum: 3165 x 1329 x 2255 mm (124.5 x 53.3 x 88.8 in.)
Pall Corporation has offices and plants throughout the world. To locate the Pall office or distributor nearest you, visit www.pall.com/contact.
The information provided in this literature was reviewed for accuracy at the time of pub-lication. Product data may be subject to change without notice. For current information consult your local Pall distributor or contact Pall directly.
IF APPLICABLE Please contact Pall Corporation to verify that the product conforms to your national legislation and/or regional regulatory requirements for water and food contact use.