ROOM NAME ABBREVIATIONS DRAWING ABBREVIATIONS INDEX OF DRAWINGS BUILDING SUMMARY
FAM RM FAMILY ROOMFEED FEEDING ROOMFF FINISH FLOORFILE FILE STORAGEFILES/ADMIN FILES ADMINISTRATIONFILM PROC FILM PROCESSING ROOMFILM READ FILM READINGFIN FINANCEFIN COUN FITNESS CTR AUTOCL FINANCIAL COUNSEL FITNESS CENTER
AUTOCLAVE/FLASH STERILIZERFLUORO FLUOROSCOPYFMWP FORMED METAL WALL PANELFOOD ST FOOD STORAGEFORM PREP FORMULA PREPARATIONFREE WGT FREE WEIGHT AREAFR SECT FROZEN SECTIONFNCTN RM FUNCTION ROOMFUT EXP FUTURE EXPANSIONG
GAR GARAGEGEN STORES GENERAL STORESGEN GENERATORGIFT GIFT SHOPGLAUC CTR GLAUCOMA CENTERGWN WTG GOWN WAITINGGWN WTG F GOWN WAITING FEMALEGWN WTG M GOWN WAITING MALEGRIEVING GRIEVING ROOMGROSS GROSSING
I
ICE ICE MACHINEINF RESUS INFANT RESUSCITATIONINFEC CTRL INFECTION CONTROLINFO INFORMATION DESKINFO SYSTEM INFORMATION SYSTEMINFUS INFUSION AREAINT INTERVIEWINV INVENTORYISOL ISOLATION ROOMIV PREP IV PREPARATIONIV ST IV STORAGE
PARTUMLAB LABORATORYLAB/SAT LABORATORY/SATELLITELDRY LAUNDRYLIB LIBRARYLIB/CONF LIBRARY/CONFERENCELIB/MEDIT LIBRARY/MEDITATIONLIGHT ADAPT LIGHT ADAPTATIONLINR ACC LINEAR ACCELERATORLIN CH LINEN CHUTELIN STR LINEN STORAGELR LIVING ROOMDOCK LOADING DOCKLKRS LOCKERSLKRS F LOCKERS FEMALELKRS M LOCKERS MALELKRS/CHNG LOCKERS/CHANGINGLONG EX LONG EXAM ROOM
M
MACH RM MACHINE ROOMMRI MAGNETIC RESONANCE IMAGINGMAIL MAIL ROOMMAINT MAINTENANCEMAMMO/STEREO MAMMOGRAPHY/STEREOTACTICMGMT MANAGEMENTMANIFOLD MANIFOLD ROOMMRKTG MARKETINGMATL MGMT MATERIALS MANAGEMENTMECH MECHANICALMECH/ELEC MECHANICAL/ELECTRICALMED REC MEDICAL RECORDSMEDS MEDICATION ROOMMEDIT MEDITATIONMTG MEETING ROOMMEZZ MEZZANINEMICRO BIO LAB MICROBIOLOGY LABORATORYMOB DK MOBILE DOCK
N
NARC CLO NARCOTICS CLOSETNICU NEONATAL INTENSIVE CARE UNITNEW NUR NEWBORN NURSERYNIGHT PHARM NIGHT PHARMACYNITROGEN ST NITROGEN STORAGENOISY ACTV NOISY ACTIVITYNOUR NOURISHMENTNUC MED NUCLEAR MEDICINENRS STA NURSE STATION
O
OBSERV OBSERVATIONOBSERV/EXAM OBSERVATION EXAMOBSERV/TREAT OBSERVATION TREATMENTOB/GYN OBSTETRIC/GYNECOLOGYOT OCCUPATIONAL THERAPYOFF OFFICEOFF SHRD OFFICE SHAREDOFF/CONF OFFICE/CONFERENCEOFF/CONS OFFICE CONSULTOFF/EXAM OFFICE/EXAMON-CALL LNG ON-CALL LOUNGEOR OPERATING ROOMOR CARDIAC OR CARDIOTHORACICOR EQ ST OR EQUIPMENT STORAGEOR ORTHO OR ORTHOPEDICORTHO ORTHOPEDIC ROOMORTHO ST ORTHOPEDIC STORAGEOSTOMY ST OSTOMY STORAGEOXYGEN ST OXYGEN STORAGE
SCHED SCHEDULINGSCOP CLN SCOPE CLEANINGSCOP ST SCOPE STORAGESCRUB ALC SCRUB ALCOVESCRUB SCRUB AREASECL SECLUSION ROOMSECUR SECURITYSEMI PRIV RM SEMI PRIVATE ROOMSERO SEROLOGYSERV SERVERYSVC SERVICESERV ENTRY SERVICE ENTRYSHELL SHELL SPACESHWR (M-MALE, F-FEMALE, SHOWER H/C - HANDICAP)SIM SIMULATORSINK ALC SINK ALCOVESITZ SITZ BATHSLP LAB SLEEP LABORATORYSLP STUDY SLEEP STUDY ROOMSOIL HOLD SOILED HOLDINGSOIL LN SOILED LINENSOIL UTL SOILED UTILITYSOL SOLARIUMSORT SORTING AREASP CARE NUR SPECIAL CARE NURSINGSPEC PROC SPECIAL PROCEDURESSP SERV SPECIAL SERVICESSP STUD SPECIAL STUDIESSP TEST SPECIAL TESTINGSPEC SPECIMENSTAGE I STAGE I - PACUSTAGE I ISOL STAGE I ISOLATION - PACUSTAGE II STAGE II - RECOVERYSTAGE II ISOL STAGE II ISOLATION - RECOVERY
A
AB ANCHOR BOLTAD AREA DRAINAC AIR CONDITIONINGACT ACOUSTICAL CEILING TILEADD ADDENDUMADD'L ADDITIONALADJ ADJACENTAFF ABOVE FINISHED FLOORAGGR AGGREGATEAL ALUM ALUMINUMALT ALTERNATEANOD ANODIZEDAPPROX APPROXIMATEARCH ARCHITECTURAL
B
B.M. BENCH MARKBD BOARDBETW BETWEENBF BACKFACEBG BUMPER GUARDBL BED LOCATORBL BUILDING LINEBLDG BUILDINGBLKG BLOCKINGBM BEAMBOT BOTTOMBR BUMPER RAILBRG BEARINGBSMT BASEMENTBU ROD BACK-UP RODBUR BUILT-UP ROOFBW BEARING WALL
C
C COMPACT PARKING SPACECC CUBICLE CURTAINCDR CARD READERCEM CEMENTCER CERAMICCG CORNER GUARDCIP CAST IN PLACECJ CONTROL JOINTCJ CONSTRUCTION JOINTCL CENTER LINECLG CEILINGCLR CLEARCMU CONCRETE MASONRY UNITCOL COLUMNCOMM COMMUNICATIONSCONC CONCRETECONN CONNECTIONCONST CONSTRUCTIONCONT CONTINUOUSCOORD COORDINATECPE CHLORINATED POLYETHYLENECORR CORRIDORCR COLD ROLLEDCR CRASH RAILCSK COUNTERSUNKCT CERAMIC TILECTD CENTEREDCTR CENTERCW CURTAIN WALLD
D DEPTHDBA DEFORMED BAR ANCHORDET DETAILDF DECORATIVE FILMDIA DIAMETERDIAPH DIAPHRAGMDIM DIMENSIONDJ DEFLECTION JOINTDL DEAD LOADDN DOWNDRG DRAWINGDS DOWN SPOUTDWGS DRAWINGSDWLS DOWELS
E
EA EACHEF EACH FACEEFG ENTRANCE FLOOR GRILLEEIFS EXTERIOR INSULATION AND
FINISH SYSTEMEJ EXPANSION JOINTEL ELEVATIONELEC ELECTRICELEV ELEVATOREOS EDGE OF SLABEQ EQUALEQUIP EQUIPMENTESC ESCALATOREW EACH WAYEWC ELECTRIC WATER COOLEREXIST EXISTINGEXP BLT EXPANSION BOLTEXT EXTERIORF
FD FLOOR DRAINFDN FOUNDATIONFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFF FINISH FLOORFHC FIRE HOSE CABINETFIB FIBERGLASSFIN FINISHFLR FLOORFS FAR SIDEFT FOOTFT FLOOR TRANSITIONFTG FOOTINGFV FIELD VERIFYFVC FIRE VALVE CABINETG
GA GAUGEGALV GALVANIZEDGB GRADE BEAMGEN GENERALGFRC GLASS-FIBER REINFORCED
HB HOSE BIBHDW HARDWAREHDWD HARDWOODHK HOOKHM HOLLOW METALHOR HORIZONTALHP HIGH POINTHR HOURHS HEADED STUDHSKP HOUSEKEEPINGHT HEIGHTHW HAND WASHHW HEAD OF WALL
I
IBC INTERNATIONAL BUILDINGCODE
ID INSIDE DIAMETERINSUL INSULATIONINT INTERIOR
K
K KIPS (1000 LB)KO KNOCK-OUTKP KICKPLATEKPD KEYPADKSF KIPS PER SQUARE FOOT
L
L ANGLELAV LAVATORYLG LONGLKB LOCKABLELL LIVE LOADLLH LONG LEG HORIZONTALLLV LONG LEG VERTICALLOC LOCATIONLP LOW POINTLT LIGHTLWC LIGHTWEIGHT CONCRETE
M
MAS MASONRYMAT'L MATERIALMAX MAXIMUMMECH MECHANICALMEMB MEMBRANEMEP MECHANICAL, ELECTRICAL
AND PLUMBINGMFG MANUFACTURERMGO MEDICAL GAS OUTLETMIN MINIMUMMISC MISCELLANEOUSMO MASONRY OPENINGMOB MEDICAL OFFICE BUILDINGMOD BIT MODIFIED BITUMENMOD MODIFIEDMSL MEAN SEA LEVELMTL METAL
N
NA NOT AVAILABLENIC NOT IN CONTRACTNOA NOTICE OF ACCEPTANCE BY FLORIDA GOVERNING
AUTHORITYNOM NOMINALNS NEAR SIDENTS NOT TO SCALENWC NORMAL WEIGHT CONCRETE
O
OA OVER ALLOC ON CENTEROD OUTSIDE DIAMETEROD OVERFLOW DRAINOFCI OWNER FURNISHED,
P LAM PLASTIC LAMINATEPC PRECAST CONCRETEPCF POUNDS PER CUBIC FOOTPCP PORTLAND CEMENT
PLASTERPENT PENTHOUSEPL PROPERTY LINEPL PLATEPLUMB PLUMBINGPLYWD PLYWOODPP PUSH PLATEPOL POLISHEDPORT CEM PORTLAND CEMENTPR PAIRPREFAB PREFABRICATEDPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPT POINTPT PNEUMATIC TUBEPTD PAINTEDR
R RISERRAD RADIUSRAF RUBBERIZED ASPHALT
FLASHINGRAM RUBBERIZED ASPHALT
MEMBRANERAU RUBBERIZED ASPHALT
UNDERLAYMENTRCP REFLECTED CEILING PLANRD ROOF DRAINREBAR REINFORCING BARRECP RECEPTACLEREF REFER OR REFERENCEREINF REINFORCINGRELOC RELOCATE/RELOCATEDREQ'D REQUIREDRFVC RECESSED FIRE VALVE
CABINETRM ROOMRO ROUGH OPENING
SAB SOUND ATTENUATION BLANKET
SBC STANDARD BUILDING CODESCHED SCHEDULESDL SUPERIMPOSED DEAD LOADSECT SECTIONS/H SINGLE HUNGSHWR SHOWERSIM SIMILARSO STRUCTURAL OPENINGSOG SLAB ON GRADESP STAND PIPESPA SPACE, SPACINGSPEC SPECIFICATIONSQ SQUARESS STAINLESS STEELSSF SOLID SURFACESTA STATIONSTC SOUND TRANSMISSION
CLASSSTD STANDARDSTIFF STIFFENERSTIR STIRRUPSTL STEELSTRUC STRUCTURALSYM SYMMETRICALSYS SYSTEM
S
T
T TREAD T&B TOP AND BOTTOMTC TOP OF CURBTEL TELEPHONETEMP TEMPERATURETHK THICKTLT TOILETTO TOP OFTOB TOP OF BEAMTOC TOP OF CONCRETETOF TOP OF FOOTINGTOP TOP OF PARAPETTOS TOP OF SLABTOSTL TOP OF STEELTRSH CH TRASH CHUTETW TOP OF WALLTYP TYPICAL
U
U/C UNDER COUNTER U/G UNDERGROUNDUNO UNLESS NOTED OTHERWISE
VAN BOERUM & FRANK ASSOCIATES, INC.MECHANICAL & PLUMBING ENGINEER
330 SOUTH 300 EAST SALT LAKE CITY, UT 84111
SPECTRUM ENGINEERS
SALT LAKE CITY, UTAH 84111
ELECTRICAL ENGINEER
324 S. STATE ST. STE. 400
12/1
0/20
18 8
:14:
09 A
M
A0.02B
PROJECT
INFORMATION
11/02/2018
22506.000
CONSTRUCTION
DOCUMENTS
PCH TI
INDEX OF DRAWINGS - PCH AUDIOLOGY
Sheet Issue StatusSHEET
NUMBER SHEET NAMECD ISSUE12-10-2018
PCH TI A0.02B PROJECT INFORMATION █PCH TI ALS.03A LIFE SAFETY PLAN - LEVEL 3 - PCH █PCH TI A2.03H PCH AUDIOLOGY FLOOR PLANS █PCH TI A2.70A FINISH INFORMATION- PCH █PCH TI A2.71 INTERIOR DETAILS - FLOOR TRANSITION DETAILS █PCH TI A3.01 PARTITION TYPES █PCH TI A3.02 PARTITION HEAD AND FRAMING DETAILS █PCH TI A3.30 DOOR, SAFETY GLAZING INFORMATION █PCH TI A3.50H INTERIOR ELEVATIONS / CABINET DETAILS █PCH TI M0.01A MECHANICAL SYMBOLS, DETAILS AND SCHEDULES █PCH TI M2.34C MECHANICAL & PLUMBING PLANS █PCH TI EE001 SYMBOL SCHEDULE, SHEET INDEX █PCH TI EP101 PCH AUDIOLOGY ELECTRICAL PLANS - LEVEL 3 █PCH TI EP501 DETAILS █PCH TI EP502 DETAILS █PCH TI EP503 DETAILS █PCH TI ET601 TELECOM DETAILS █PCH TI EC601 SYSTEM DIAGRAMS █PCH TI EC602 SYSTEM DIAGRAMS █
NO. DESCRIPTION DATE
LIFE SAFETY PLAN LEGEND
EXIT ENCLOSURE
EXIT CORRIDOR
SUITE
BUSINESS OCCUPANCY
EXIT SYMBOL
EXIT SIGN -HATCH INDICATES
EXIT TEXT AND ARROW
INDICATES DIRECTION
ASSEMBLY
1 HR FIRE BARRIER
2 HR FIRE BARRIER
SMOKE PARTITION (NON RATED)NON RATED WALL
SMOKE COMPARTMENT WALL
2 HR FIRE / SMOKE BARRIER
FIRE DEPARTMENT CONNECTION
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
TRAVEL DISTANCE FROM THE MOST REMOTE
POINT TO THE CLOSEST EXIT
TRAVEL DISTANCE WITHIN A SMOKE ZONE TO AN ADJACENT
SMOKE ZONE
XXX'-X"
XXX'-X"
FDC
FEC
FE
FDC
OCCUPANCY SEPARATION WALL
HORIZONTAL EXIT WALL
1 HR FIRE / SMOKE BARRIER
RETAIL
STORAGE
3-HR FIRE WALL - BUILDING SEPARATION (I-2 TO B)& HORIZONTAL EXIT
FEC
FEC
FEC
20
3' -
0"
B OCCUPANCYI-2 OCCUPANCY
NO SMOKE COMPARTMENTS REQUIRED
EXTENT OF CURRENT SCOPE. ALL OTHER AREAS REVIEWEDWITH PREVIOUSLY ISSUEDCONSTRUCTION DOCUMENTS
VAN BOERUM & FRANK ASSOCIATES, INC.MECHANICAL & PLUMBING ENGINEER
330 SOUTH 300 EAST SALT LAKE CITY, UT 84111
SPECTRUM ENGINEERS
SALT LAKE CITY, UTAH 84111
ELECTRICAL ENGINEER
324 S. STATE ST. STE. 400
12/1
0/20
18 7
:34:
48 A
M
ALS.03A
LIFE SAFETY PLAN -
LEVEL 3 - PCH
12/10/2018
22506.000
CONSTRUCTION
DOCUMENTS
PCH TI
1" = 20'-0"01 LIFE SAFETY PLAN - LEVEL 3 - PCH TINOTE: CROSS-HATCHED AREA INDICATES SCOPE PREVIOUSLY ISSUED. REFER TO BID PACKAGE #3
THIRD LEVEL PCH B-OCCUPANCY SUMMARY
AREA PRIMARY USE AREA OL FACTOR OCCUPANT LOAD
CLINIC BUSINESS 922 SF 100 SF 10CLINIC BUSINESS 1908 SF 100 SF 20CLINIC MECHANICAL 343 SF 300 SF 2CLINIC BUSINESS 897 SF 100 SF 9CLINIC BUSINESS 1222 SF 100 SF 13CLINIC BUSINESS 300 SF 100 SF 4REHAB CLINIC BUSINESS 448 SF 100 SF 5REHAB CLINIC BUSINESS 2468 SF 100 SF 25REHAB CLINIC BUSINESS 845 SF 100 SF 9REHAB CLINIC BUSINESS 750 SF 100 SF 8REHAB CLINIC BUSINESS 289 SF 100 SF 3REHAB CLINIC STORAGE 126 SF 300 SF 1GRAND TOTAL 10517 SF 109
NO. DESCRIPTION DATE
CLG HT AFF
REF RCP FOR
S T
4
4.8
5.7
2.9
3' -
0"
6' - 0"
2' - 0" 6' - 8"
1/20 GRADE RISE(NOT A RAMP)(NO HANDRAILS)4" RISE
7' - 0" 9' - 3 1/4"
12' -
0"
5' -
0"12
' - 0
"
6" 6 1/4"
2' - 4"
5"
A3
EXIST
A3
A3
EXIST
EXIST
A3 EXISTA3 EXISTPW
A3
A3A3
A3
A3
A3 A3
A3A3
NG
NG
EXAM 1
34214
EXAM 2
34216
PAT TLT
34218
EXAM 3
34220
ECHO
34230
EEG
34234
EXAM
34226
AUD EXAM
34227
LAB
34229
CORRIDOR
34231
AUD EXAM
34233
OFFICE
34235
CORRIDOR
34237
AUD EXAM
34238AUD
CONTROL
34239
CORR
34246
A3
A3
A3
A3
A3
A3
A3
A3
CO
RR
IDO
R
3424
1
6"
NEW ALUMINUMDOOR / FRAMEAND GLAZING -SEE A3.30 ELEVATION
PATCH CEILING SYSTEMWHERE DISTURBED TO PROVIDE NEW BULKHEADREMOVE EXISTING WALL AS
NECESSARY TO FORM BULKHEAD
5' - 0"
4' -
6"4'
- 6"
5' - 0" CUBICLECURTAIN TRACKS
3-5/8" METALSTUD / GYPBOARD BULKHEAD
CEILINGS BYBOOTH VENDOR BULKHEAD BOTTOM IS INTENDED
TO BE 1/2" ABOVE THE TOPOF THE BOOTH
+9'-0" (ABOVE MAINFLOOR LEVEL)
NEW GYP BDCEILING ONHORIZONTALMETAL STUDFRAMING(INTEGRATE INTOEXISTING CEILING)
+8'-6"
+9'-0" EXPOSED TOSTRUCTURE
EXPOSED TOSTRUCTURE
S T
4
4.8
5.75.7
2.9
SHVB20SHV20
WP011,2,3,4
EXAM 134214
SHVB20SHV20
WP01
EXAM 234216
1,2,3,4
SHVB20SHV20
WP011,2,3,4
EXAM 334220
SHVB20SHV20
WP01
EEG34234
1,2,3,4
PTB03PT03
CT06
PAT TLT34218
3,5
032
032
032
IPT20
IPT22
SH
V25
SH
V20
SH
V25
SH
V20
SH
V25
SH
V20
SH
V25
SH
V20
IPT06
CT07
TYP.5' - 0"
IPT06
IPT06
SHV18
SHV18(EXIST)
2' - 0"
13' - 1 1/2"
SHV18
CPT06 CPT06
NEW SHEET VINYL
EXISTING CARPETAND BASE TOREMAIN - PROVIDETRANSITION STRIP
CB06CPT06
IPT27
AUD EXAM34227
3, 4SHVB20SHV20
IPT27
LAB34229
4
SHVB18SHV18
IPT01
CORRIDOR34231
4
CB06CPT06
IPT27
AUD EXAM34233
3, 4
CB06CPT06
IPT27
OFFICE34235
3
SHVB18SHV18
IPT01
CORRIDOR34241
4
CB06CPT06
IPT01
CORRIDOR34237
4
SHVB18SHV18
IPT01
CORR34246
3,4
IPT
06IP
T06
SHELLED SPACE -NO FINISHES
SHELLED SPACE -NO FINISHES
SHELLED SPACE -NO FINISHES
PREFABRICATEDRAMP WITH INTEGRALSLIP RESISTANTSURFACE
WP
CB06CB06
PAINT NEW CEILINGAREA TO MATCH ADJACENTGYP BD
PATCH / PROVIDE NEW CARPET FLOORING AND BASE:CARPET (CPT01) SHAW, QUARTZ TILE, 5T017, ZIRCON, 18X36BASE (CB01) SHAW, DESIGN SERIES V30
PAINT DISTURBED WALLSIPT01:SHERWIN WILLIAM, 7005, PURE WHITE
CG2
CG2
CG2
CG2
CG2
FLOOR PLAN / FINISH GENERAL NOTES
1. REFER TO SHEET A3.01 FOR PARTITION TYPES, GRAPHIC AND SYMBOLIC DESIGNATIONS, NOTES, AND DETAILS
'EXIST' NEXT TO WALL TYPE SYMBOL INDICATES THE WALL TYPEIS EXISTING (SHOWN FOR REFERENCE)
2. REFER TO SHEET A3.50 FOR INTERIOR ELEVATIONS, MILLWORK DETAILS AND INFORMATION3. DIMENSIONS ARE TO FACE OF DRYWALL OR FINISH, U.N.O. 4. COORDINATE WALL DEMOLITION REQUIRED FOR UTILITY WORK. NOT ALL WALL PATCH LOCATIONS MAY BE INDICATED5. PROVIDE 2 HOUR FLOOR PENETRATION SEALS WHERE PIPING OR CONDUIT PENETRATES FLOOR BELOW AND FLOOR ABOVE6. PATCH ALL SPRAYED ON FIREPROOFING WHERE DISTRBUTED BY DEMOLITION OR REMODEL CONSTRUCTION, TO ORIGINAL CONDITION, AS DETERMINED BY THE BUILDING OFFICIAL7. ELEVATED FLOOR AREA (ELEVATED 4" TO MATCH HEIGHT OF AUDIOLOGY BOOTH FLOOR) SHALL BE CONSTRUCTED OF 2-1/2" METAL STUDS AT 12" O.C. (16 GA), 5/8" CEMENT BOARD (PERPENDICULAR TO METAL STUDS) AND 1" CONCRETE TOPPING. RAMP SHALL BE 'PRARIE VIEW INDUSTRIES' SL##36 RAMP OR EQUAL (CUSTOM FABRICATE RAMP WITH SLOPE TO BE 1/20 OR LESS) RAMP SHALL BE FASTENED TO FLOOR WITH 2" EXPANSION ANCHORS (COUNTERSUNK HEADS)8. 'FUTURE DEVELOPED SPACE' SHALL RECEIVE TAPED AND MUDDED DRYWALL FINISH (TO MEET 1 HOUR WALL RATING) ON THE UNFINISHED SIDE OF THE WALL
SHEET KEYNOTES
'NG' PROVIDE NEW GYP BD ON EXIST STUD AND GYP FRAMING - FULL HEIGHT, IN THIS ROOM AS REQUIRED TO ACHIEVE 'G' WALL TYPE ASSEMBLY. SEE WALL TYPES ON SHEET A3.01
'PW' PATCH EXISTING GYP BD WALL AS NECESSARY AFTER INSTALLATION OF UTILITIES AND/OR WHERE EXISTING WALLS ARE REMOVED OR MODIFIED. NOT ALL LOCATIONS MAY BE INDICATED. COORDINATE WITH DEMOLITION
AND UTILITY DRAWINGS. PROVIDE NEW WALL AND BASE FINISH ON ENTIRE WALL.
"WP' PAINT ENTIRE WALL WHERE DISTURBED BY DEMOLITION OR REMODEL WORK. MATCH EXISTING PAINT COLOR
4 7/8"
TYP
3"4"
3 5/8" METAL STUD DIAGONAL SUPPORT AT 48" OC MAX
CLG AS SCHED
5/8" GYP BD ON MTL STUDS
LINE OF STRUCTURE
3 5/8" MTL STUD HOR BRACING -BRACE AT 24" OC WHEN VERTICAL HEIGHT EXCEEDS 48"
3 5/8" MTL STUDS AT 16" OC
2" X 22 GA CONTINUOUS METAL STRAP TYP EACH SIDE
TYPICAL: 12 GA AT LAY-IN CLNG OR 8 GA AT GYP BD CLG VERTICAL HANGER WIRE AT 4'-0" EA WAY W/ MIN 3 TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE TYPICAL (8" OUT FROM WALL TYP)12 GA AT LAY-IN CLG OR 8 GA AT GYP BD CLG BRACING WIRE W/ MIN 4 TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE TYP PROVIDED ORIENTED 90 TO EACH OTHER AT 12'-0" OC 1ST POINT 6' FROM EACH WALLCOMPRESSION STRUTS: 1 1/2" DEEP 20 GA WALL STUD ATTACH TO MAIN RUNNERS WITH 1/4" MACHINE BOLT AND TO STRUCTURE WITH 3/16" DIAMETER POWER-DRIVEN FASTENER. COMPRESSION STRUT SHALL NOT REPLACE HANGER WIRE
MAIN RUNNER
CROSS RUNNER
2" (MAX) FROM BRACING WIRES TO CROSS RUNNERS
CEILING FIXTUR
E 45°
MAX (TYP)
12 GA AT LAY-IN CLG OR 8 GA AT GYP BD CLNG WIRE ATTACHED TO OPPOSING CORNERS AT FIXTURES DIAGONAL
1. ICBO (INTERNATIONAL COUNCIL OF BUILDING OFFICIALS) EVALUATION REPORT - 4071 GYPSUM WALLBOARD (066). (THIS REPORT HAS THE SAME REQUIREMENTS FOR GYP BD CEILINGS AND LAY-IN CEILING.
2. ALL LATERAL SUPPORTS MUST BE LOCATED A MIN OF 6" (152mm) FROM HORIZONTAL UNBRACED PIPES AND DUCTWORK.
3. VERTICAL STRUTS FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. THE STRUT SHALL BE ADEQUATE TO RESIST THE VERTICAL LOAD INDUCED BY THE BARRIER WIRES.
4. THE VERTICAL STRUTS AT HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12'-0" (3658mm) OC IN BOTH DIRECTIONS, WITH THE FIRST POINT WITHIN 6'-0" (1830mm) FROM EACH WALL.
1 MULTIPLE FLOOR FINISHES IN THIS AREA, REFER TO PLANS FOR MORE INFORMATION.2 MULTIPLE BASE FINISHES IN THIS AREA, REFER TO PLANS AND ELEVATIONS FOR MORE
INFORMATION.3 MULTIPLE WALL FINISHES IN THIS AREA. REFER TO PLANS AND ELEVATIONS FOR MORE
INFORMATION.4 INTEGRAL COVE BASE IN THIS AREA.5 EPOXY PAINT TO BE USED IN THIS AREA.6 IPT01 TO BE USED AT THIS LOCATION ABOVE WALL FINISH UNLESS NOTED OTHERWISE7 PORCELAIN TILE TO BE INSTALLED FULL HEIGHT AT WET WALL AND BEHIND SINK LOCATIONS.
PORCELAIN TILE TO BE INSTALLED 60"H ABOVE PORCELAIN TILE COVE BASE CAPPED WITH METALTRIM PIECE (MT02) AT ALL OTHER WALLS. TILE TO BE INSTALLED IN STACKED INSTALLATION.
8 INTEGRAL COVED BASE SHALL BE 6" HIGH9 ALL PENETRATIONS IN THIS AREA INCLUDING LIGHTING, HVAC, PLUMBING, ETC THROUGH CEILINGS
OR WALLS MUST BE SEALED
2. NEW CEILINGS ARE ACT02, TYPICAL
PAINT IPT01:SHERWIN WILLIAMS SW7005 PURE WHITE
NO. DESCRIPTION DATE
LINEN/STORAGE0254
VT01RB01IPT01
ROOM NUMBERROOM NAME
FLOORBASETYPICAL WALL
*REMARKS NUMBERS COORDINATE WITH FINISH REMARKS LEGEND LOCATED ON ALL FINISH FLOOR PLAN SHEETS
1*REMARKS
FINISH TAG LEGEND
RS01 A B
"A" INDICATES MOTORIZED SHADE IF "A" IS OMITTED SHADE IS MANUALLY OPERATED
INDICATES FABRIC SELECTION - SEE FINISH SCHEDULE
ROLLER SHADE TAG LEGEND
"B" INDICATES DOUBLE ROLL W/ BLACK OUT SHADE - SEE RS02 IN FINISH SCHEDULE, IF "B" IS OMITTED SHADE IS A SINGLE ROLL SHADE
PROVIDE 18" ACCENT PAINT (IPT24) FROM EDGE OF DOOR FRAME TO DRYWALL REVEAL.REFER TO ELEVATIONS FOR MORE INFO.
INTERIOR FINISH PLAN NOTES_PCH
030031 PROVIDE 18" ACCENT PAINT (IPT18) FROM EDGE OF DOOR FRAME TO DRYWALL REVEAL.REFER TO ELEVATIONS FOR MORE INFO.032 PROVIDE 18" ACCENT PAINT (IPT06) FROM EDGE OF DOOR FRAME TO DRYWALL REVEAL.REFER TO ELEVATIONS FOR MORE INFO.033 PROVIDE 18" ACCENT PAINT (IPT27) FROM EDGE OF DOOR FRAME TO DRYWALL REVEAL.REFER TO ELEVATIONS FOR MORE INFO.
VAN BOERUM & FRANK ASSOCIATES, INC.MECHANICAL & PLUMBING ENGINEER
330 SOUTH 300 EAST SALT LAKE CITY, UT 84111
SPECTRUM ENGINEERS
SALT LAKE CITY, UTAH 84111
ELECTRICAL ENGINEER
324 S. STATE ST. STE. 400
12/1
0/20
18 7
:34:
35 A
M
A2.70A
FINISH INFORMATION-
PCH
11/07/2018
22506.000
CONSTRUCTION
DOCUMENTS
PCH TI
INTERIOR FINISH GENERAL NOTES
1 PATTERN NAME, COLOR AND NUMBER FOR EACH MATERIAL ARE GIVEN WHEREVER POSSIBLE ON THE FINISH PLAN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TOBRING ANY DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT/DESIGNER SO THAT THE CORRECT MATERIAL IS INSTALLED.
2 REFERENCE A2 SERIES DRAWINGS FOR INTERIOR FINISH PLANS.3 REFERENCE A2 SERIES FOR WALL PROTECTION LOCATIONS.4 REFERENCE SHEET A3.24 FOR TYPES AND CONFIGURATIONS OF WALL PROTECTION.5 REFERENCE A2.71 FOR TYPICAL FLOORING TRANSITION DETAILS.6 REFERENCE A3 SERIES DRAWINGS FOR MILLWORK INFORMATION.7 REFERENCE A3 SERIES DRAWINGS FOR INTERIOR SPECIALTY ELEVATIONS.8 REFERENCE A4 SERIES FOR ALL CEILING FINISHES.9 REFERENCE A3.24 FOR TYPICAL WALL PROTECTION ELEVATION FINISHES AND MOUNTING HEIGHT LOCATIONS & LOCKER FINISH INFORMATION.10 DRYWALL TO RECEIVE A LEVEL FIVE (5) FINISH EVERYWHERE.11 ALL PT/CT EXPOSED OUTSIDE CORNERS SHALL RECEIVE MT01.12 ALL CORNER GUARDS ARE CG02, UNO.13 WELDING ROD AT WELDED SEAMS IN SHEET VINYL SHALL MATCH THE DARKER OF THE SHEET VINYL COLORS AT SEAMS THAT DIVIDE TWO COLORS UNLESS NOTED
OTHERWISE.14 WHEN SHOWN, INSTALL INTEGRAL BASE TO A HEIGHT OF 4" AFF, UNO.15 ALL FLOORING TRANSITIONS SHALL BE CENTERED UNDER THE DOOR IN THE CLOSED POSITION.16 DASHED IN FURNITURE TO BE O.F.O.I.17 ALL FLOORING TO BE INSTALLED PERPENDICULAR TO ROOM WALLS UNLESS NOTED OTHERWISE.18 BULKHEADS/SOFFITS/FURDOWNS SHOULD BE FINISHED WITH THE SAME MATERIAL AND OR COLOR ON ALL FACES AS SPECIFIED, UNLESS SPECIFICALLY NOTED OTHERWISE.19 ALL MATERIALS AND FINISHES TO BE INSTALLED ACCORDING TO MANUFACTURERS RECOMENDATIONS. ANY DISCREPANCIES BETWEEN WHAT IS INDICATED ON DRAWINGS
AND MANUFACTURERS INSTRUCTIONS SHOULD BE BROUGHT TO THE ARCHITECTS ATTENTION IMMEDIATELY AND PRIOR TO ORDER AND INSTALLATION OF MATERIALS.20 WHERE ATYPICAL CONDITIONS OCCUR, CONTRACTOR IS TO VERIFY FINISH TREATMENT WITH ARCHITECT BEFORE PROCEEDING.21 WIREWAYS, ACCESS PANELS, MECHANICAL DEVICES, ETC. SHALL BE FINISHED TO MATCH ADJACENT SURFACE UNLESS NOTED OTHERWISE.22 PROVIDE CRACK ISOLATION MEMBRANCE AS REQUIRED AT ALL PORCELAIN TILE FLOORING. FLOORING CONTRACTOR TO COORDINATE WITH DESIGNER.23 CONTINUE ALL FLOORING MATERIALS BENEATH ALL CASEWORK. MILLWORK, FURNTIURE, INCLUDING KNEESPACES, UNLESS NOTED OTHERWISE.24 CUT TILES TO NEVER BE LESS THAN 3". IF NECESSARY, CUT (2) TILES TO MAKE UP THE DIFFERENCE25 REFER TO PROJECT MANUAL SECTION "CAST-IN-PLACE CONCRETE" FOR SPECIFICATIONS FOR SEALED CONCRETE (SC) AND HARDENER/SEALER OR HARDENER SEALED
CONCRETE (HSC)27 AT I-2 OCCUPANCIES, ALL INTERIOR WALL AND CEILING FINISHES TO MEET CLASS B INTERIOR FINISH REQUIREMENTS. ADMINISTRATIVE AND ROOMS WITH A CAPACITY OF LESS
THAN 4 PERSONS ARE PERMITTED TO HAVE CLASS C INTERIOR FINISHES AS NOTED ON IBC TABLE 803.928 AT B OCCUPANCIES, ALL INTERIOR WALL AND CEILING FINISHES TO MEET CLASS C INTERIOR FINISH REQUIREMENTS AS NOTED ON IBC TABLE 803.929 AT U OCCUPANCIES, THERE ARE NO RESTRICTIONS REGARDING INTERIOR FINISHES30 ALL WALLS TO BE PAINTED IPT01 UNLESS NOTED OTHERWISE.31 ALL WALLS WITHIN PRIMARY CHILDREN'S SUITE TO BE PAINTED IPT27 UNLESS NOTED OTHERWISE
IPT01 HOLLOW METAL FRAMESIPT01 GYPSUM BOARD HORIZONTAL SOFFIT SURFACES AND CEILINGSIPT01 INTERIOR HOLLOW METAL DOORSIPT06 EXPOSED DUCTWORKIPT06 PREFINISHED GRILLES/DIFFUSERS ON EXPOSED DUCTWORKIPTXX EXPOSED STRUCTURE, ROOF DECK, AND MEP COMPONENTSIPTXX METAL PORTIONS OF STAIRS
XX ELECTRICAL DEVICES COLOR (COORDINATE W/ELECTRICAL)WD01 INTERIOR WOOD DOORSCLC01 EXPOSED COLUMNSPL01 VERTICAL CASEWORK/MILLWORK TO BE PLASTIC LAMINATE, UNLESS NOTED OTHERWISE
SSF01 HORIZONTAL COUNTERTOPS TO BE SOLID SURFACE UNLESS NOTED OTHERWISE
INTERIOR FINISH REMARKS
1 MULTIPLE FLOOR FINISHES IN THIS AREA, REFER TO PLANS FOR MORE INFORMATION.2 MULTIPLE BASE FINISHES IN THIS AREA, REFER TO PLANS AND ELEVATIONS FOR MORE
INFORMATION.3 MULTIPLE WALL FINISHES IN THIS AREA. REFER TO PLANS AND ELEVATIONS FOR MORE
INFORMATION.4 INTEGRAL COVE BASE IN THIS AREA.5 EPOXY PAINT TO BE USED IN THIS AREA.6 IPT01 TO BE USED AT THIS LOCATION ABOVE WALL FINISH UNLESS NOTED OTHERWISE7 PORCELAIN TILE TO BE INSTALLED FULL HEIGHT AT WET WALL AND BEHIND SINK LOCATIONS.
PORCELAIN TILE TO BE INSTALLED 60"H ABOVE PORCELAIN TILE COVE BASE CAPPED WITH METALTRIM PIECE (MT02) AT ALL OTHER WALLS. TILE TO BE INSTALLED IN STACKED INSTALLATION.
8 INTEGRAL COVED BASE SHALL BE 6" HIGH9 ALL PENETRATIONS IN THIS AREA INCLUDING LIGHTING, HVAC, PLUMBING, ETC THROUGH CEILINGS
OR WALLS MUST BE SEALED
INTERIOR FINISH PLAN NOTES
001 ALIGN FLOOR TRANSITION WITH ADJACENT WALL OR EDGE OF MILLWORK002 PAINTED DRYWALL CONTROL JOINT AT THIS LOCATION. REFER TO FINISH PLANS AND ARCHITECTURAL INTERIOR ELEVATIONS FOR
ADDITIONAL INFORMATION REGUARDING THE PAINT AND REVEAL PATTERN INFORMATION.029 INSTALL TILE OR CARPET TILE IN DIRECTION OF ARROW.
INTERIOR DESIGN SELECTION SUMMARY - PCH TI
NAME MANUFACTURER STYLE NUMBER COLOR SIZE COMMENTS CONTACT
ACOUSTICAL CEILING TILEACT02 ARMSTRONG OPTIMA SQUARE LAY-IN 3152 WHITE 24" X 24" USE GRID: SDG01 MATTHEW SANDER 323.219.5036
CORNER GUARDSCG01 C/S ACROVYN CORNER GUARD SM-20N PUMICE 3" LEGS X 4' HIGH PVC FREECG02 C/S ACROVYN CORNER GUARD SM-20N PUMICE 3" LEGS X 8' HIGH PVC FREECG15 C/S ACROVYN ACROVYN 4000 END GUARD SSM-25MN TBD 2" LEGS X 8' HIGH PVC FREE
INTERIOR PAINTIPT03 SHERWIN WILLIAMS SW6106 KILIM BEIGE 2 COATS MINIMUM TOM BRUMMETT 310.999.9396IPT05 SHERWIN WILLIAMS SW6478 WATERY 2 COATS MINIMUM TOM BRUMMETT 310.999.9396IPT06 SHERWIN WILLIAMS SW7611 TRANQUIL AQUA 2 COATS MINIMUM TOM BRUMMETT 310.999.9396IPT08 SHERWIN WILLIAMS SW6423 RYE GRASS 2 COATS MINIMUM TOM BRUMMETT 310.999.9396IPT18 SHERWIN WILLIAMS SW6367 VIVA GOLD 2 COATS MINIMUM TOM BRUMMETT 310.999.9396IPT20 SHERWIN WILLIAMS SW6492 JETSTREAM 2 COATS MINIMUM TOM BRUMMETT 310.999.9396IPT24 SHERWIN WILLIAMS SW6508 SECURE BLUE 2 COATS MINIMUM TOM BRUMMETT 310.999.9396IPT25 SHERWIN WILLIAMS SW6710 MELANGE GREEN 2 COATS MINIMUM TOM BRUMMETT 310.999.9396IPT26 SHERWIN WILLIAMS SW9018 HONEY BEES 2 COATS MINIMUM TOM BRUMMETT 310.999.9396IPT27 BENJAMIN MOORE OC14 NATURAL CREAM 2 COATS MINIMUM CONSTANCE 201.912.2829
PLASTIC LAMINATEPL01 ARBORITE W-465 EV MOCHA MODERN CHERRY WOODLOOK EILEEN WALKER 714.388.8420PL05 ARBORITE P-355 RM WEATHERED HEMP OFFICE COUNTER TOPS NON
FURNITUREEILEEN WALKER 714.388.8420
PL08 ARBORITE W-464 EV BLONDE MODERN CHERRY EILEEN WALKER 714.388.8420
SHEET VINYL BASESHVB17 JOHNSONITE ACCENT WOOD 29012 ALLOVER WOOD BROWN 6" HIGH ELLEN WREN 440.708.5873SHVB18 JOHNSONITE OPTIMA 861 CLOVER LEAF 6" HIGH ELLEN WREN 440.708.5873SHVB19 JOHNSONITE OPTIMA 843 PACIFICA 6" HIGH ELLEN WREN 440.708.5873SHVB20 JOHNSONITE OPTIMA 821 FROTHY LATTE 6" HIGH ELLEN WREN 440.708.5873SHVB21 JOHNSONITE OPTIMA 863 ABLAZED 6" HIGH ELLEN WREN 440.708.5873SHVB22 JOHNSONITE OPTIMA 831 HOT GINGER 6" HIGH ELLEN WREN 440.708.5873SHVB23 JOHNSONITE OPTIMA 834 PARSLEY 6" HIGH ELLEN WREN 440.708.5873SHVB24 JOHNSONITE OPTIMA 838 SEASPRAY 6" HIGH ELLEN WREN 440.708.5873SHVB25 JOHNSONITE OPTIMA 839 SUBMERGED 6" HIGH ELLEN WREN 440.708.5873
SHEET VINYL FLOORINGSHV17 JOHNSONITE ACCENT WOOD 29012 ALLOVER WOOD BROWN SHEET ELLEN WREN 440.708.5873SHV18 JOHNSONITE OPTIMA 861 CLOVER LEAF SHEET ELLEN WREN 440.708.5873SHV19 JOHNSONITE OPTIMA 843 PACIFICA SHEET ELLEN WREN 440.708.5873SHV20 JOHNSONITE OPTIMA 821 FROTHY LATTE SHEET ELLEN WREN 440.708.5873SHV21 JOHNSONITE OPTIMA 863 ABLAZED SHEET ELLEN WREN 440.708.5873SHV22 JOHNSONITE OPTIMA 831 HOT GINGER SHEET ELLEN WREN 440.708.5873SHV23 JOHNSONITE OPTIMA 834 PARSLEY SHEET ELLEN WREN 440.708.5873SHV24 JOHNSONITE OPTIMA 838 SEASPRAY SHEET ELLEN WREN 440.708.5873SHV25 JOHNSONITE OPTIMA 839 SUBMERGED SHEET ELLEN WREN 440.708.5873
SUSPENDED DECORATIVE GRIDSDG01 ARMSTRONG PRELUDE XL 15/16" WHITE LAY-IN MATTHEW SANDER 323.219.5036
NO. DESCRIPTION DATE
(SCHLUTER SCHIENE)(SCHLUTER SCHIENE)
(SCHLUTER SCHIENE)
(MERCER 633)
(MERCER 705)
TYPE FT-17
TYPE FT-16
TYPE FT-11
TYPE FT-10
TYPE FT-14
TYPE FT-15
METAL STRIPS
LEVELING COMPOUND
RESILIENT FLOORING
THIN-SET TERRAZZO
DIVIDER STRIP
1/4" TILE RESILIENT FLOORING
LEVELING COMPOUND
LEVELING COMPOUND
1/4" CARPETRESILIENT FLOORING
1/4" TILE 1/4" CARPET
LEVELING COMPOUND
CONCRETERESILIENT FLOORING
CENTERLINEDOOR &
THRESHOLD
VINYL MOULDINGS
1/4" TO 5/16" GLUE DOWN CARPET
1/4" CARPETSHEET VINYL
CENTERLINEDOOR &
THRESHOLD
NOTE: USE JOHNSONITE SLT-49-A (BEIGE) WITH SHV01, SHV02, SHV03, & SHV04 (HOSPITAL PORTION)USE SLT-20-A (CHARCOAL) WITH ALL OTHER SHV SELECTIONS (CLINIC PORTION)
VAN BOERUM & FRANK ASSOCIATES, INC.MECHANICAL & PLUMBING ENGINEER
330 SOUTH 300 EAST SALT LAKE CITY, UT 84111
SPECTRUM ENGINEERS
SALT LAKE CITY, UTAH 84111
ELECTRICAL ENGINEER
324 S. STATE ST. STE. 400
12/1
0/20
18 7
:34:
37 A
M
A2.71
INTERIOR DETAILS -
FLOOR TRANSITION
DETAILS
11/07/2018
22506.000
CONSTRUCTION
DOCUMENTS
FLOOR TRANSITIONS SCALE: HALF
1/2" = 1'-0"08 CARPET TILE INSTALLATION
3" = 1'-0"12 BASE DETAIL-SHEET VINYL 6"
NO. DESCRIPTION DATE
REFER TO PARTITION HEAD DETAILS
SEALANT
MTL RUNNER
SEALANT
MTL RUNNER
5/8" GYP BD EACH SIDE
LINE OF STRUCTURE
LINE OF CEILING
LINE OF STRUCTURE
FLOOR PLAN DESIGNATION NO SOUND ATTENUATION
FLOOR PLAN DESIGNATION WITH SOUND ATTENUATION
STUD SIZE
PART WIDTH
FIRE RATING
UL LISTING
WITH SOUND
STC:NO SOUND
REMARKS
3 5/8" 4 7/8"NON-
RATED N/A 49W/3" SAB
40
2 1/2"
6"
3 5/8"
2 1/2"
6"
3 5/8"
2 1/2"
6"
3 5/8"
3 3/4"
7 1/4"
4 7/8"
3 3/4"
4 7/8"
7 1/4"
3 3/4"
7 1/4"
4 7/8"
NON-RATED
NON-RATED
SMOKE RESIST
SMOKE RESIST
SMOKE RESIST
ONE HOUR
ONE HOUR
ONE HOUR
ONE HOUR/ SMOKE RESIST
U465 49W/3" SAB
40
2 1/2" 3 3/4"
ONE HOUR/ SMOKE RESIST
N/A 49W/3" SAB
40
6" 7 1/4"
ONE HOUR/ SMOKE RESIST
U465 49W/3" SAB
40
N/A
N/A
N/A
N/A
N/A
U465
N/A
U465
49W/3" SAB
40
49W/3" SAB
40
49W/3" SAB
40
49W/3" SAB
40
49W/3" SAB
40
49W/3" SAB
40
49W/3" SAB
40
49W/3" SAB
40
REFER TO PARTITION HEAD DETAILS
TYPE "G"
SEALANT
MTL RUNNER
SEALANT
MTL RUNNER
2 LAYERS 5/8" GYP BD ONE SIDE ONLY
LINE OF STRUCTURE
LINE OF CEILING
LINE OF STRUCTURE
3 5/8" 5 1/2"NON-
RATED N/A 51W/3" SAB
44
2 1/2"
6"
3 5/8"
4 3/8"
7 7/8"
5 1/2"
NON-RATED
NON-RATED
ONE HOUR/ SMOKE RESIST
U419 51W/3" SAB
44
2 1/2" 4 3/8"
ONE HOUR/ SMOKE RESIST
U419
6" 7 7/8"
ONE HOUR/ SMOKE RESIST
U419
3 5/8" 5 1/2"SMOKE RESIST
2 1/2"
6"
4 3/8"
7 7/8"
SMOKE RESIST
SMOKE RESIST
3 5/8" 5 1/2"ONE
HOUR U419
2 1/2"
6"
4 3/8"
7 7/8"
ONE HOUR
ONE HOUR
U419
U419
N/A
N/A
N/A
N/A
N/A
51W/3" SAB
44
51W/3" SAB
44
51W/3" SAB
44
51W/3" SAB
44
51W/3" SAB
44
51W/3" SAB
44
51W/3" SAB
44
51W/3" SAB
44
51W/3" SAB
44
51W/3" SAB
44
REFER TO PARTITION HEAD DETAILS
TYPE "H"
MTL RUNNER
SEALANT
MTL RUNNER
5/8" GYP BD
3 5/8" 4 1/4"NON-
RATED N/A
2 1/2"
6"
3 1/8"
6 5/8"
NON-RATED
NON-RATED
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
LINE OF STRUCTURE
LINE OF STRUCTURE
REFER TO PARTITION HEAD DETAILS
TYPE "J"
MTL RUNNER
SEALANT
MTL RUNNER
5/8" GYP BD
3 5/8" 4 1/4"NON-
RATED N/A
2 1/2"
6"
3 1/8"
6 5/8"
NON-RATED
NON-RATED
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
LINE OF STRUCTURE
LINE OF STRUCTURE
LINE OF CEILING
TYPE "K"
1 5/8" 3"NON-
RATED N/A
2 1/2"
3 5/8"
4"
5"
NON-RATED
NON-RATED
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
SEALANT
MTL RUNNER
5/8" GYP BD
LINE OF STRUCTURE
LINE OF STRUCTURE
BRACE EACH STUD AT 4'-0" OC VERTICALLY
LINE OF STRUCTURE OR OTHER CONSTRUCTION PROVIDING BACK-UP FOR STUD BRACING
A3 A3
A2 A2
A6 A6
A3
A2 A2
A6 A6
A3
A2 A2
A6 A6
A3
A2 A2
A6 A6
G3 G3
G2 G2
G6 G6
G3 G3
G2 G2
G6 G6
G3 G3
G2 G2
G6 G6
G6 G6
G2 G2
G3 G3
H3
H2
H6
J3
J2
J6
K1
K2
K3
FLOOR PLAN DESIGNATION NO SOUND ATTENUATION
FLOOR PLAN DESIGNATION WITH SOUND ATTENUATION
STUD SIZE
PART WIDTH
FIRE RATING
UL LISTING
WITH SOUND
STC:NO SOUND
REMARKS
FLOOR PLAN DESIGNATION NO SOUND ATTENUATION
FLOOR PLAN DESIGNATION WITH SOUND ATTENUATION
STUD SIZE
PART WIDTH
FIRE RATING
UL LISTING
SOUND TRANS CLASS REMARKS
FLOOR PLAN DESIGNATION NO SOUND ATTENUATION
FLOOR PLAN DESIGNATION WITH SOUND ATTENUATION
STUD SIZE
PART WIDTH
FIRE RATING
UL LISTING
REMARKS
FLOOR PLAN DESIGNATION NO SOUND ATTENUATION
FLOOR PLAN DESIGNATION WITH SOUND ATTENUATION
STUD SIZE
PART WIDTH
FIRE RATING
UL LISTING
REMARKS
LINE OF CEILING
LINE OF CEILING
TYPE "A"
PARTITION WIDTH
REFER TO SCHEDULEBELOW FOR
PARTITION WIDTH
REFER TO SCHEDULEBELOW FOR
3"
PARTITION WIDTH
REFER TO SCHEDULEBELOW FOR
PARTITION WIDTH
REFER TO SCHEDULEBELOW FOR
3"
PARTITION WIDTH 3" MIN
REFER TO SCHEDULEBELOW FOR
SOUND TRANS CLASS
SOUND TRANS CLASS
NOTES
PARTITION TYPE INCLUDED IN SCOPE OF WORK
PARTITION TYPE NOT INCLUDED IN SCOPE OF WORK
1. PARTITIONS ARE DISTINGUISHED ON FLOOR PLANS BY SYMBOL DESIGNATION, GRAPHIC DESIGNATION OR A COMBINATION OF BOTH DESIGNATIONS.
2. THERE ARE TWO TYPES OF SYMBOL DESIGNATIONS, ONE FOR PARTITIONS NOT REQUIRING SOUND ATTENUATION AND ANOTHER FOR PARTITIONS WHICH REQUIRE SOUND ATTENUATION. REFER TO PARTITION MATRICES FOR SOUND ATTENUATION BLANKET (SAB) MINIMUM THICKNESS FOR STC INDICATED.
3. THERE ARE TWO SYMBOL DESIGNATION SYSTEMS USED. THE FIRST SYSTEM CONSISTS OF TWO AND THREE CHARACTERS, THE FIRST CHARACTER IS A LETTER INDICATING THE PARTITION TYPE. THE SECOND CHARACTER IS NUMERIC INDICATING THE STUD OR CMU WIDTH. REFER TO LEGEND BELOW. THIS SYSTEM IS USED TO DEFINE WALL TYPES: A, B, C, D, E, F, H, J, K, M, R
THE # CHARACTER BELOW THE LINE INDICATES THE HEIGHT OF THE SPECIFIC WALL COMPONENT. THE HEIGHT OF A SPECIFIC WALL COMPONENT. REFER TO THE LEGEND BELOW. THIS SYSTEM IS USED TO DEFINE WALL TYPES: G, L, P, Q, S, T, U, W, X, Y, Z
4. IF NO SYMBOL DESIGNATION IS PROVIDED, THE STUD SIZE WILL BE 3 5/8".
5. THE GRAPHIC DESIGNATION IS INCORPORATED FOR PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT. REFER TO NOTE 18.
6. "LINE OF STRUCTURE" INDICATED FOR EACH PARTITION IS DIAGRAMMATIC ONLY AND DOES NOT INDICATE EXACT CONSTRUCTION CONDITIONS OR GEOMETRY.
7. ALL DIMENSIONS ARE FROM FACE OF GYPSUM BOARD TO FACE OF GYPSUM BOARD. REFER TO PARTITION MATRICES FOR PARTITION WIDTH DIMENSIONS UNLESS INDICATED TO BE SHOWN ON PLAN.
8. SEALANT:1. FIRE RESISTANCE RATED PARTITIONS SHALL USE RATED FIRE/SMOKE FIRE RESISTANT FILL
MATERIAL IN CONJUNCTION WITH AN APPROPRIATE RATED FIRE/SMOKE FIRE STOPPING SYSTEM.
2. NON-RATED PARTITIONS AND NON-RATED SMOKE RESISTANT PARTITIONS SHALL USE ACOUSTICAL SEALANT.
9. INSULATION: - HEAD CONDITIONS AT FLOOR/ROOF DECK1. FIRE RESISTANCE RATED PARTITIONS SHALL USE MINERAL WOOL INSULATION.2. NON-RATED PARTITIONS REQUIRING SOUND ATTENUATION SHALL USE SOUND ATTENUATION BLANKETS (SAB).3. PROVIDE FULL THICKNESS INSULATION INSIDE ALL STUD BOX BEAMS AND HEADERS WHICH
OCCUR IN WALLS WITH SOUND ATTENUATION.
10. REFER TO SPECIFICATIONS FOR MINIMUM STUD THICKNESS, MAXIMUM SPACING AND ALLOWABLE LIMITING HEIGHTS DEFLECTION CRITERIA FOR GYPSUM BOARD ASSEMBLIES.
11. FOR PARTITIONS INDICATED TO RECEIVE SOUND ATTENUATION BLANKETS (SAB), EXTEND SAB TO FULL HEIGHT OF PARTITION UNLESS OTHERWISE INDICATED. FLOOR TRACK TO BE SET IN A CONT BED OF SEALANT.
12. FIRE RESISTANT AND FIRE RESISTANT SMOKE BARRIER RATINGS ARE TO SURROUND ALL OPENINGS IN RATED PARTITIONS.
NUMERIC CHARACTER
STUD WIDTH
CMU WIDTH
12346812
1 5/8"2 1/2"3 5/8"
4"6"
3 5/8"5 5/8"7 5/8"
11 5/8"
13. SMOKE RESISTANT, FIRE RESISTANT, AND FIRE RESISTANT SMOKE BARRIER PARTITIONS SHALL EXTEND AND SEAL TO INSIDE FACE OF EXTERIOR SHEATHING, INCLUDING EXTENSIONS THROUGH SOFFITS.
14. EACH PARTITION SHOWN ON THE DRAWINGS TO HAVE A FIRE AND SMOKE RESISTANT RATING SHALL BE IDENTIFIED AS SUCH WITH A LABEL ABOVE THE CEILING ON EACH SEGMENT OF THE WALL AND 6' - 0" OC MAX EACH SIDE.
15. REFER TO TOILET ACCESSORIES SHEET AND CASEWORK SHEET FOR MOUNTING DETAIL INFORMATION.
16. REFER TO THE METAL FABRICATIONS DETAILS FOR MF REFERENCES IN PARTITIONS SECTION.
17. REFER TO STRUCTURAL DRAWINGS FOR REINFORCING INFORMATION.
18. GRAPHIC DESIGNATION
19. DO NOT APPLY BULLNOSE BLOCK AT CORNER GUARD LOCATIONS.
FLUTED STEEL DECK/CONCRETE FLOOR OR ROOF PERPENDICULAR OR DIAGONAL TO
FLUTES
CONT 2" WIDE X 22 GA MTL STRAP FOR TOP ATTACHMENT OF GYP BD
CONT 20 GA MIN 3" DEEP LEG DEFLECTION TRACK ATTACH TO DECK AT 12" OC MAX
DO NOT ATTACH GYP BD OR STUDS TO DEFLECTION TRACK IN THIS AREA
SEALANT
NON-RATED OR SMOKE RESISTANT
CONCRETE FLOOR OR ROOF
CONT 20 GA MIN 3" DEEP LEG DEFLECTION TRACK ATTACH TO DECK AT 12" OC MAXDO NOT ATTACH
GYP BD OR STUDS TO DEFLECTION TRACK IN THIS AREA
SEALANT
CONT 2" WIDE X 22 GA MTL STRAP FOR TOP ATTACHMENT OF STUDS
1"
1"
1"
4"
NON-RATED
FLUTED STEEL DECK/CONCRETE FLOOR OR ROOF PERPENDICULAR OR DIAGONAL TO
FLUTES
LINE OF CEILING AS SCHEDULED
CONT 2" WIDE X 22 GA MTL STRAP FOR TOP ATTACHMENT OF STUDS
CONT 20 GA MIN 3" DEEP LEG DEFLECTION TRACK ATTACH TO DECK AT 12" OC MAX
DO NOT ATTACH GYP BD OR STUDS TO DEFLECTION TRACK IN THIS AREA
1"
4"
LINE OF CEILING AS SCHEDULED
CONT 2" WIDE X 22 GA MTL STRAP FOR TOP ATTACHMENT OF STUDS
CONT 20 GA MIN 3" DEEP LEG DEFLECTION TRACK ATTACH TO DECK AT 12" OC MAXDO NOT ATTACH
GYP BD OR STUDS TO DEFLECTION TRACK IN THIS AREA
NON-RATED
CONCRETE FLOOR OR ROOF
1"
4 1/
8"
LINE OF CEILING AS SCHEDULED
CONT 2" WIDE X 22 GA MTL STRAP FOR TOP ATTACHMENT OF STUDS
DO NOT ATTACH GYP BD OR STUDS TO DEFLECTION TRACK IN THIS AREA
CONT 20 GA MIN 3" DEEP LEG DEFLECTION TRACK ATTACH TO DECK AT 12" OC MAX
WHEN PARTITION IS ALIGNED AT DECK FLUTE RECESS - PROVIDE A 6" X 10" X 22 GA MTL PLATE AT DECK FLUTE RECESS THAT IS CONTIGUOUS WITH PARTITION - ATTACH MTL PLATE TO DECK WITH POWDER DRIVEN FASTENERS AT SAME SPACING REQUIRED FOR PARTITION TOP TRACK
NON-RATED
FLUTED STEEL DECK/CONCRETE FLOOR OR ROOF PARALLEL TO FLUTES
3/4"
3/4"
3/4" 3/
4"
3/4"
1"
4 1/
8"
NON-RATED OR SMOKE RESISTANT
FLUTED STEEL DECK/CONCRETE FLOOR OR ROOF PARALLEL TO FLUTES
CONT 2" WIDE X 22 GA MTL STRAP FOR TOP ATTACHMENT OF GYP BD
CONT 20 GA MIN 3" DEEP LEG DEFLECTION TRACK ATTACH TO DECK AT 12" OC MAX
DO NOT ATTACH GYP BD OR STUDS TO DEFLECTION TRACK IN THIS AREA
SEAL ONE SIDE OF PARTITION AGAINST PASSAGE OF SMOKE
WHEN PARTITION IS ALIGNED AT DECK FLUTE RECESS - PROVIDE A 6" X 10" X 22 GA MTL PLATE AT DECK FLUTE RECESS THAT IS CONTIGUOUS WITH PARTITION - ATTACH MTL PLATE TO DECK WITH POWDER DRIVEN FASTENERS AT SAME SPACING REQUIRED FOR PARTITION TOP TRACK
1"
1"
4 1/
8"
ONE HOUR FIRE RESISTANT AND ONE HOUR
FIRE RESISTANT SMOKE BARRIER
UL-HW-D-0107
FLUTED STEEL DECK/CONCRETE FLOOR OR ROOF PARALLEL TO FLUTES
DO NOT ATTACH GYP BD OR STUDS TO DEFLECTION TRACK IN THIS AREA
SPRAY APPLIED FIRESTOP MATERIAL EACH SIDE - MIN 1/2" OVERLAP AT GYP BD AND DECK
CONT 2" WIDE X 22 GA MTL STRAP -ATTACH GYP BD TO STRAP AT 8" OC MAX
FILL GAP BETWEEN SLAB AND TOP OF WALL WITH MINERAL WOOL INSULATION
CONT 22 GA MIN 3" DEEP LEG DEFLECTION TRACK ATTACH TO DECK AT 12" OC MAX 1
1/2"
4"
1"
1"
4 1/
8"
1 1/
2"
SPRAY APPLIED FIRESTOP MATERIAL EACH SIDE - MIN 1/2" OVERLAP AT GYP BD AND DECK CONT 2" WIDE X 22 GA MTL STRAP -ATTACH GYP BD TO STRAP AT 8" OC MAX
DO NOT ATTACH GYP BD OR STUDS TO DEFLECTION TRACK IN THIS AREA
CONT 20 GA MIN 3" DEEP LEG DEFLECTION TRACK ATTACH TO DECK AT 12" OC MAXFILL DECK FLUTE RECESS WITH MINERAL WOOL INSULATION
ONE HOUR FIRE RESISTANT AND ONE HOUR
FIRE RESISTANT SMOKE BARRIER
UL-HW-D-0107
FLUTED STEEL DECK/CONCRETE FLOOR OR ROOF PERPENDICULAR OR DIAGONAL TO
FLUTES
1"
1"
4 1/
4"
1 1/
2"
FILL GAP BETWEEN SLAB AND TOP OF WALL WITH MINERAL WOOL INSULATION
SPRAY APPLIED FIRESTOP MATERIAL EACH SIDE - MIN 1/2" OVERLAP AT GYP BD AND DECK
CONT 2" WIDE X 22 GA MTL STRAP -ATTACH GYP BD TO STRAP AT 8" OC MAX
DO NOT ATTACH GYP BD OR STUDS TO DEFLECTION TRACK IN THIS AREA
CONT 20 GA MIN 3" DEEP LEG DEFLECTION TRACK ATTACH TO DECK AT 12" OC MAX
ONE HOUR FIRE RESISTANT AND ONE
HOUR FIRE RESISTANT SMOKE BARRIER
UL-HW-D-0108
CONCRETE FLOOR OR ROOF SLAB
1"
1"1"
4 3/
8"
CONT 2" WIDE X 22 GA MTL STRAP -ATTACH GYP BD TO STRAP AT 8" OC MAX
DO NOT ATTACH GYP BD OR STUDS TO DEFLECTION TRACK IN THIS AREA
CONT 20 GA MIN 3" DEEP LEG DEFLECTION TRACK ATTACH TO Z CLIP AT 16" OC MAX
CONT 20 GA FORMED Z CLIP WITH 2" LEGS -ATTACH TO BEAM AT 16" OC MAX
SPRAYED FIRE RESISTIVE MATERIAL
SPRAY APPLIED FIRESTOP MATERIAL EACH SIDE - MIN 1/2" OVERLAP AT GYP BD AND DECK
FILL GAP BETWEEN SPRAYED FIRE RESISTIVE MATERIAL AND TOP OF WALL WITH MINERAL WOOL INSULATION
FILL FLUTES ABOVE BEAMS WITH SPRAYED FIRE RESISTIVE MATERIAL
ONE HOUR FIRE RESISTANT AND ONE HOUR
FIRE RESISTANT SMOKE BARRIER
UL-HW-D-0267
FLUTED STEEL DECK/CONCRETE FLOOR OR ROOF PERPENDICULAR OR DIAGONAL TO
FLUTES
PARTITION HEAD DETAILS
NOTE:REFER TO UL LISTING FOR COMPLETE ASSEMBLY REQUIREMENTS
NOTE:REFER TO UL LISTING FOR COMPLETE ASSEMBLY REQUIREMENTS
NOTE:REFER TO UL LISTING FOR COMPLETE ASSEMBLY REQUIREMENTS
NOTE:REFER TO UL LISTING FOR COMPLETE ASSEMBLY REQUIREMENTS
3/4"
3/4"
3/4"
.
MINERAL WOOL INSULATION
3/4"
3/4"
3/4"
CONT 20 GA GALV MTL STRAP ACROSS MTL DECK FLUTES
3/4"
22 GA MIN MTL TRACK AT FLOOR
DOUBLE 18 GA MTL STUDS AT BOTH JAMBS
2 1/2" X 2 1/2" 20 GA MTL STRAP AT 2'-0" OC WITH 4 SCREWS (2 INTO EACH STUD EA SIDE)
COUNTERTOP DESIGNATION IF OTHER THAN PLASTIC LAMINATE
CABINET ELEVATION ABBREVIATION
VIEW ICON INDICATES ORIENTATION OF VIEW ON PLANCABINET GENERAL
NOTES1. CABINET WIDTHS TO BE BASED ON MODULE INCREMENTS OF 3" UNO.
2. PROVIDE FILLER PANELS TO FINISH OUT TO SCRIBE CABINETS TO WALL.
3. PROVIDE FILLER PANELS AND TRIM WHERE EQUIPMENT IS LOCATED WITHIN CABINETS.
4. PROVIDE FINISHED END PANELS END RETURNS AT OPEN ENDED CABINETS, KNEE SPACES, AND ACCESSIBLE SINKS.
5. PROVIDE 1 1/2" THICK FINISHED END PANEL AT FREE STANDING END OF ACCESSIBLE SINKS AND KNEE SPACES.
6. WHEN FILLER PANELS ARE REQUIRED AT BOTH ENDS OF CASEWORK TERMINATION, BOTH FILLER PANELS SHALL BE EQUAL WIDTH.
7. PROVIDE WALL BRACKET SUPPORTS AT 36" OC MAX TO SUPPORT COUNTERTOP AT CONTINUOUS KNEE SPACE.
8. PROVIDE END SPLASH WHEN COUNTERTOP IS ADJACENT TO WALL AT SIDES.
9. PROVIDE HOLES FOR GROMMETS IN COUNTERTOPS AND AT THE FOLLOWING LOCATIONS: - 1 EACH WIRE ACCESS HOLE WITH GROMMET AT KNEE SPACE. - WIRE ACCESS HOLES WITH GROMMETS AT 38" OC FOR CONTINUOUS RUNS OF KNEE SPACE. - 1 WIRE ACCESS GROMMET BEHIND EACH KEYBOARD DRAWER. - 1 COMPUTER PAPER SLOT GROMMET BEHIND EACH PRINTER.
10. PROVIDE ADJUSTABLE SHELVES IN CABINETS AT THE FOLLOWING LOCATIONS UNO ON ELEVATIONS: - BASE CABINET - 1 SHELF - FULL HEIGHT CABINET - 5 SHELVES, 1 FIXED. - WALL CABINET - 1 SHELF AT 24" HIGH, 2 SHELVES AT TALLER CABINETS NOTE: SHELVES TO BE 3/4" THICK FOR SPANS UP TO 32" AND 1" THICK FOR SPANS UP TO 36".
11. GLASS FRONTS TO BE 1/4" THICK CLEAR TEMPERED GLASS UNO.
12. PROVIDE AN APRON AT ALL KNEE SPACES 30" OR HIGHER UNO.
13. VERTICAL SURFACES TO BE PLASTIC LAMINATE (PL01) UNO. HORIZONTAL SURFACES TO BE SOLID SURFACE (SSF01) UNO.
14. FILLER PANEL FINISHED WITH WOOD GRAIN LAMINATE SHALL HAVE THEIR GRAIN RUNNING IN THE SAME DIRECTION AS THE CABINET.
FASCIA PANEL JOINTS8'-0" MAX BETWEEN
TASK LIGHTING
ALIGN FASCIA PANEL JOINTS WITH WALL CABINET JOINTS
VR-B3-46 PRICE SDV SHELL SPACE 8 450 135 135 80 25 22 3.5 0.5 WATER (1)(2)(3)(4)
(1) ENTERING AIR AT 52 DEG. F. @ 4,300 FEET ELEVATION.
(2) GPM BASED ON 130 DEG. F. ENTERING WATER TEMPERATURE; 100 DEG. F. LEAVING WATER TEMPERATURE.
(3) COIL MAXIMUM WATER P.D. AT 5.0 FT HD; MAXIMUM BOX AIR P.D. IS 0.40 IN. W.G.
(4) PRESSURE INDEPENDENT TYPE BOX.
PLUMBING FIXTURE SCHEDULECW HW W V
ID FIXTURE (IN) (IN) (IN) (IN) NOTES
S-1 WORK SINK 1/2 1/2 2 1 1/2
SINK (BASIN INTEGRAL TO COUNTERTOP): CHICAGO 786-GN8FCXKABCP FAUCET, WITH WRIST BLADE HANDLES, GN8FC RIGID/SWING GOOSENECK SPOUT WITH 1.5 GPM LAMINAR FLOW CONTROL IN SPOUT. WATTSLFUSG-B-M2 THERMOSTATIC MIXING VALVE WITH WATTS # 7 DUAL CHECK VALVES ON HOT AND COLD LINES INSTALLED IN CEILING. FLEXIBLE STAINLESS STEEL SUPPLIES WITH WITH LOOSE KEY ANGLE STOPS.; FLEXIBLESTAINLESS STEEL SUPPLIES WITH LOOSE KEY ANGLE STOPS; CHICAGO 327-XCP OPEN-GRID STRAINER AND CAST BRASS P-TRAP WITH CLEAN OUT PLUG. PROVIDE ADA COMPLIANT UNDER COUNTER PIPING WRAP BYTRUE-BRO, COLOR TO BE WHITE.
S-2 2-COMP SINK 1/2 1/2 1 1/2 1 1/2
SINK (STAINLESS STEEL, COUNTER MOUNTED, DOUBLE COMPARTMENT): ELKAY LR4322 18 GA. TYPE 304 STAINLESS STEEL SINK, 33"X22"X6-1/2" DEEP, CHICAGO 786-GN8FCABCP FAUCET, WITH WRIST BLADE HANDLES,RIGID/SWING GOOSENECK SPOUT WITH 1.5 GPM LAMINAR FLOW CONTROL IN SPOUT. WATTS LFUSG-B-M2 THERMOSTATIC MIXING VALVE WITH ZURN MODEL SXL STRAINERS AND ZURN MODEL 40XL2 CHECK VALVES ONHOT AND COLD LINES INSTALLED IN CEILING. FLEXIBLE STAINLESS STEEL SUPPLIES WITH WITH LOOSE KEY ANGLE STOPS.; FLEXIBLE STAINLESS STEEL SUPPLIES WITH LOOSE KEY ANGLE STOPS; CHICAGO 327-XCPOPEN-GRID STRAINER AND CAST BRASS P-TRAP WITH CLEAN OUT PLUG. PROVIDE ADA COMPLIANT UNDER COUNTER PIPING WRAP BY TRUE-BRO, COLOR TO BE WHITE.
GRILLES, REGISTERS AND DIFFUSERSMAX MAX
ID MANUFACTURER MODEL SIZE CFM NC DESCRIPTION
6'' DIA 110 SQUARE PLAQUE CEILING DIFFUSERS. REMOVABLE FACE & CORE
8'' DIA 235 FRAME SHALL BE FOR SURFACE OR LAY-IN MOUNTING AS REQUIRED
CD-1 EH PRICE SPD 10'' DIA 420 30 BY CEILING TYPE. LAY-IN FRAMES SHALL BE 24" x 24", 24" x 12"
12'' DIA 600 OR 12" x 12" AS REQUIRED TO FIT CEILING TILE SPACE AVAILABLE.
14'' DIA 800 PROVIDE ROUND NECK ADAPTER. COLOR TO BE SELECTED BY ARCHITECT.
15'' DIA 850
6'' DIA 100 PERFORATED FACE RETURN AIR GRILLE, REMOVABLE FACE & CORE.
8'' DIA 210 FRAME SHALL BE FOR SURFACE OR LAY-IN MOUNTING AS REQUIRED
RG-1 / EG-1 EH PRICE PDDR 10'' DIA 380 30 BY CEILING TYPE. LAY-IN FRAMES SHALL BE 24" x 24", 24" x 12" OR
12'' DIA 600 12" x 12" AS REQUIRED TO FIT CEILING TILE SPACE AVAILABLE. AIR
14'' DIA 750 QUANTITY SHALL MATCH ROOM SUPPLY OR EXHAUST AIR QUANTITY.
15'' DIA 1000 PROVIDE ROUND NECK ADAPTER. COLOR TO BE SELECTED BY ARCHITECT.
LAVATORY MIXING VALVE DETAIL
NO SCALE
HWS
HWR
HIGH EFFICIENCY TAKE-OFF DETAIL
NO SCALE
CABLE BRACING FOR ROUND AND OVAL DUCTS
VARIABLE VOLUME BOX DETAIL
NO SCALE
DIFFUSER CONNECTION DETAIL
NO SCALE
VAV/CV BOX PIPING DETAIL WITH 2-WAY AUTO-VALVE
NO SCALE
FIRE DAMPER & FIRE/SMOKE DAMPER DETAILS
NO SCALE
BRANCH DUCT TAKE-OFF & DAMPER
NO SCALENO SCALE
RECTANGULAR DUCT
AIR FLOW
45°
FLEX DUCT
VOLUME DAMPER
RECTANGLE TO
ROUND TRANSITION
SEE CONNECTION SCHEDULE AND DETAILS
CABLE-SEE DETAIL, BRACING ANDCONNECTION SCHEDULES FOR SIZEOF ANGLE, BOLT AND CABLE.
DUCT HANGER ASRECOMMENDEDBY SMACNA
1 1/2" X12 GA. SHEETMETAL HANGER STRAP
2 1/2" X 12 GA. SHEETMETAL RESTRAINT STRAP INSULATION WHERE
OCCURS
4545
W
INACCESSIBLEDAMPER ISOPERATOR WHEREREMOTE CEILING
45
L=1/4 W (4" MIN.)NOTE:
L
AIR FLOW
INTERSECTIONSTO ELBOWS ORTHAN TWO DUCT WIDTHSBE INSTALLED CLOSERDAMPERS SHOULD NOTNOTE:
PRODUCTS, CATALOG NUMBER DISCREPANCIES, DISCREPANCIES BETWEEN
THE EQUIPMENT SUPPLIED AND THE INTENT OR FUNCTION OF THE
EQUIPMENT, ETC, SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER IN
WRITING FOR CLARIFICATION PRIOR TO ISSUANCE OF THE FINAL ADDENDUM
AND BIDDING OF THE PROJECT. WHERE DISCREPANCIES OR MULTIPLE
INTERPRETATIONS OCCUR, THE MOST STRINGENT (WHICH IS GENERALLY
RECOGNIZED AS THE MOST COSTLY) THAT MEETS THE INTENT OF THE
DOCUMENTS SHALL BE ENFORCED.
2. OWNER FURNISHED ITEMS: THE OWNER WILL FURNISH MATERIAL AND
EQUIPMENT AS INDICATED IN THE CONTRACT DOCUMENTS TO BE
INCORPORATED INTO THE WORK. THESE ITEMS ARE ASSIGNED TO THE
INSTALLER AND COSTS FOR RECEIVING, HANDLING, STORAGE, IF REQUIRED,
AND INSTALLATION ARE INCLUDED IN THE CONTRACT SUM.
A. THE INSTALLER'S RESPONSIBILITIES ARE THE SAME AS IF THE INSTALLER
FURNISHED THE MATERIALS OR EQUIPMENT.
B. THE OWNER WILL ARRANGE AND PAY FOR DELIVERY OF OWNER
FURNISHED ITEMS FREIGHT ON BOARD JOB SITE AND THE INSTALLER
WILL INSPECT DELIVERIES FOR DAMAGE. IF OWNER FURNISHED ITEMS
ARE DAMAGED, DEFECTIVE OR MISSING, DOCUMENT DAMAGED ITEMS
WITH THE TRANSPORT COMPANY AND THE OWNER WILL ARRANGE FOR
REPLACEMENT. THE OWNER WILL ALSO ARRANGE FOR
MANUFACTURER'S FIELD SERVICES, AND THE DELIVERY OF
MANUFACTURER'S WARRANTIES AND BONDS TO THE INSTALLER.
C. THE INSTALLER IS RESPONSIBLE FOR DESIGNATING THE DELIVERY DATES
OF OWNER FURNISHED ITEMS AND FOR RECEIVING, UNLOADING AND
HANDLING OWNER FURNISHED ITEMS AT THE SITE. THE INSTALLER IS
RESPONSIBLE FOR PROTECTING OWNER FURNISHED ITEMS FROM
DAMAGE, INCLUDING DAMAGE FROM EXPOSURE TO THE ELEMENTS, AND
TO REPAIR OR REPLACE ITEMS DAMAGED AS A RESULT OF HIS
OPERATIONS.
3. EXPOSED STRUCTURE AREAS (EXCLUDING MECHANICAL, ELECTRICAL, AND
COMMUNICATION SPACES): INSTALL RACEWAYS BETWEEN DECK AND
STRUCTURE WHEREVER POSSIBLE IN EXPOSED STRUCTURE CEILING AREAS.
ROUTE RACEWAYS IN CONCEALED AREAS WHEREVER POSSIBLE. REFER ALL
CONDITIONS WHERE RACEWAYS MUST BE INSTALLED WHICH CANNOT
COMPLY WITH THESE REQUIREMENTS TO THE ARCHITECT.
4. SUBMITTALS: PROVIDE SUBMITTALS IN THREE RING BINDERS WITH JOB NAME,
SUBCONTRACTOR, AND VOLUME ON THE BINDING. PREPARE TABS FOR EACH
SPECIFICATION SECTION REQUIRING SUBMITTALS. PREPARE INDEX OF
EQUIPMENT SUBMITTED IN EACH TAB.
5. REFLECTED CEILING PLANS: COORDINATE THE LOCATION OF LIGHT FIXTURES
WITH THE ARCHITECTURAL REFLECTED CEILING PLANS. REFER ALL
DISCREPANCIES TO THE ARCHITECT AND ENGINEER.
CONTRACT LIMIT LINE: DASHDOT, WIDE LINE.
PROPERTY LINE: DASHED, WIDE LINE.
DEMOLITION LINE: DASHED, MEDIUM LINE.
EXISTING TO REMAIN LINE: THIN LINE.
HIDDEN FEATURES LINE: HIDDEN, THIN LINE.
NEW LINE: MEDIUM LINE.
MATCH LINE INDICATOR: CENTER, EXTRA WIDE LINE.
BREAK, ROUND.
BREAK, STRAIGHT: TO BREAK PARTS OF DRAWING.
EQUIPMENT INDICATOR.
REVISION INDICATOR.
KEYNOTE INDICATOR.
ROOM OR SPACE NUMBER.
ELEVATION OR SECTION INDICATOR, INTERIOR: A5INDICATES ELEVATION OR SECTION NUMBER, E-201INDICATES DRAWING SHEET WHERE ELEVATION OR SECTIONIS SHOWN.
ELEVATION OR SECTION INDICATOR, EXTERIOR: A5INDICATES ELEVATION OR SECTION NUMBER, E-201INDICATES DRAWING SHEET WHERE ELEVATION OR SECTIONIS SHOWN.
DETAIL INDICATOR: A5 INDICATES DETAIL NUMBER, E-501INDICATES DRAWING SHEET WHERE DETAIL IS SHOWN.
REFERENCE AND LINE SYMBOLS
MATCH LINE
SEE XX/X-XXX
CU-1
1
1
100
A5
E-201
A5
E-201
A5
E-501
LADDER RACK.
JUNCTION BOX, CEILING.C
EARTH GROUND (ONE-LINE DIAGRAM).
WIREWAY.
PULL BOX.
DUCT CELL FLOOR HEADER.
JUNCTION BOX, DUCT, UNDERFLOOR. TRIPLE, DOUBLE ORSINGLE DUCT SYSTEM AS INDICATED BY THE NUMBER OFPARALLEL LINES. DESIGNATIONS AS SHOWN FOR WIRINGAND/OR RACEWAY SYMBOLS.
JUNCTION BOX, SYSTEMS FURNITURE POWER CONNECTION.SP
JUNCTION BOX, SYSTEMS FURNITURE COMMUNICATION CONNECTION.SC
JUNCTION BOX.
CONDUCTOR RUN IDENTIFICATION.
CONDUCTOR & CONDUIT ("CC") SCHEDULE INDICATOR.REFER TO ONE-LINE DIAGRAM.
CONDUIT STUB. DIMENSION RECORD DRAWINGS AND MARK.
LOW VOLTAGE WIRING: DIVIDE, MEDIUM LINE.
FLEXIBLE WIRING.
WIRING TURNED DOWN OR AWAY FROM OBSERVER.
WIRING TURNED UP OR TOWARDS OBSERVER.
WIRING.
WIRING METHODS
J
W W
PB
J
J
J
1
1
WIRING AND/OR RACEWAY: THIN LINE. WHERE "X" = :
CATV = CABLE TELEVISIONCCTV = CLOSED CIRCUIT TELEVISION
FEEDER HOMERUN: REFER TO ONE-LINE DIAGRAMS ANDEQUIPMENT SCHEDULE FOR CONDUIT AND CONDUCTORREQUIREMENTS. ARROWS DO NOT NECESSARILY INDICATE THEQUANTITY OF CONDUCTORS.
ADP-1
BRANCH CIRCUIT HOME RUN TO PANELBOARD: NUMBEROF ARROWS INDICATES NUMBER OF CIRCUITS. LETTERAND NUMBER NOTATIONS IDENTIFY PANEL AND CIRCUITNUMBERS. USE #12 CONDUCTORS, EXCEPT #10CONDUCTORS SHALL BE INSTALLED IF DISTANCES EXCEEDTHOSE SPECIFIED IN THE ELECTRICAL SPECIFICATIONS.
A-1,3,5
WIRING DEVICES
RECEPTACLE, DUPLEX, WEATHERPROOF: NEMA 5-20R.WP
RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUITINTERRUPTER, WET LABEL, "WEATHERPROOF IN USE":NEMA 5-20R.W
RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUITINTERRUPTER, WEATHERPROOF: NEMA 5-20R.WP
RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUITINTERRUPTER: NEMA 5-20R.
RECEPTACLE, DUPLEX, CONNECTED TO UPS: NEMA 5-20R.
RECEPTACLE, DUPLEX ON EMERGENCY POWER: NEMA 5-20R.
RECEPTACLE, DUPLEX, FLOOR, UNDER CARPET: NEMA 5-20R.UC
RECEPTACLE, DUPLEX, SWITCHED: NEMA 5-20R.
RECEPTACLE, DUPLEX, ISOLATED GROUND: NEMA 5-20R.IG
RECEPTACLE, DUPLEX, DEDICATED CIRCUIT: NEMA 5-20R.D
RECEPTACLE, DUPLEX, CEILING: NEMA 5-20R.C
RECEPTACLE, DUPLEX, ABOVE COUNTER: NEMA 5-20R.A
RECEPTACLE, DUPLEX: NEMA 5-20R.
RECEPTACLE, SINGLE: NEMA 5-20R.
S
DF
RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUITINTERRUPTER, DRINKING FOUNTAIN: CONCEAL WATERCOOLER RECEPTACLE BEHIND WATER COOLER. SEEMECHANICAL/PLUMBING SHOP DRAWINGS FORINSTALLATION REQUIREMENTS.
TRANSITION CABINET (ONE-LINE DIAGRAM).
PANELBOARD WITH CIRCUIT BREAKER AND SUB FEEDLUGS (ONE-LINE DIAGRAM).
PANELBOARD WITH SUB FEED LUGS (ONE-LINE DIAGRAM).
PANELBOARD WITH MAIN LUGS ONLY AND SURGEPROTECTION WITH CIRCUIT BREAKER (ONE-LINE DIAGRAM).
PANELBOARD WITH MAIN AND SUB FEED CIRCUITBREAKER (ONE-LINE DIAGRAM).
PANELBOARD WITH MAIN CIRCUIT BREAKER. SIZE ANDPHASE AS SHOWN (ONE-LINE DIAGRAM).
PANELBOARD WITH MAIN LUGS ONLY. BUS SIZE ANDPHASE AS SHOWN (ONE-LINE DIAGRAM).
PANELBOARD (ONE-LINE DIAGRAM).
CAPACITOR (ONE-LINE DIAGRAM).
BATTERY (ONE-LINE DIAGRAM).
TRANSFORMER, CURRENT (ONE-LINE DIAGRAM).
TRANSFORMER (ONE-LINE DIAGRAM).
EXHAUST FAN OUTLET.
MOTOR.
CIRCUIT BREAKER, SOLID STATE WITH GROUND FAULTPROTECTION (ONE-LINE DIAGRAM).
GFP
CIRCUIT BREAKER, SOLID STATE (ONE-LINE DIAGRAM).
CIRCUIT BREAKER, MOTOR CIRCUIT PROTECTION(ONE-LINE DIAGRAM).
CIRCUIT BREAKER, MOLDED CASE WITH SHUNT TRIP(ONE-LINE DIAGRAM).
STARTER (ONE-LINE DIAGRAM).
ELECTRICAL POWER AND DISTRIBUTION
225/3
"1H" "1H"
225/3 225/3"1H" "1H"
25/3
225/3
"1H"
60/3
225/3
"1H"
225/3
"1H"
225/3
"1H"
"1H"
F
MCP
STARTER, COMBINATION WITH DISCONNECT SWITCH.
DISCONNECT SWITCH, UNFUSED.
DISCONNECT SWITCH, FUSED.
75 TRANSFORMER: NUMBER INDICATES kVA.
SWITCH, TOGGLE MOTOR STARTER WITH OVERLOAD PROTECTION.
LIGHTING RELAY, CONTACTOR PANEL, OR DIMMING ENCLOSURE.
DISTRIBUTION PANEL OR SWITCHBOARD.
PANELBOARD CABINET, SURFACE MOUNTED, 2 SECTION.
PANELBOARD CABINET, SURFACE MOUNTED, 1 SECTION.
PANELBOARD CABINET, FLUSH MOUNTED.
PUSHBUTTONS, MOTOR CONTROL.
PUSHBUTTON.
STARTER OR MOTOR CONTROLLER.
VARIABLE FREQUENCY MOTOR CONTROLLER (ONE-LINE DIAGRAM).
METER.
GENERATOR, POWER (ONE-LINE DIAGRAM).
GENERATOR, ANNUNCIATOR (ONE-LINE DIAGRAM).G
SERVICE ENTRANCE SURGE PROTECTION (ONE-LINE DIAGRAM).
DIGITAL MULTIMETER (ONE-LINE DIAGRAM).
TRANSFER SWITCH (ONE-LINE DIAGRAM).
CT CABINET PER UTILITY'S REQUIREMENTS (ONE-LINE DIAGRAM).
ALARM, HORN/STROBE, ONE ASSEMBLY, CEILING MOUNTED. SUBSCRIPT INDICATES CANDELA RATING.
ALARM, HORN/STROBE, ONE ASSEMBLY. SUBSCRIPTINDICATES CANDELA RATING.
FIRE AND SMOKE DAMPER.
SMOKE DAMPER.
DETECTOR, TAMPER SWITCH WITH VALVE: TAMPERSWITCHES SHALL BE PROVIDED AND INSTALLED WITH FIRESPRINKLER SYSTEM AND SHALL BE CONNECTED TOLOCATIONS SHOWN ON THE FIRE SPRINKLER SHOPDRAWINGS.
DETECTOR, FLOW SWITCH: FLOW SWITCHES SHALL BEPROVIDED AND INSTALLED WITH FIRE SPRINKLER SYSTEMAND SHALL BE CONNECTED TO LOCATIONS SHOWN ONTHE FIRE SPRINKLER SHOP DRAWINGS.
ALARM, MINI HORN/STROBE, ONE ASSEMBLY.
ALARM, HORN/STROBE WITH GUARD, ONE ASSEMBLY.
ALARM, CHIME/STROBE, ONE ASSEMBLY.
ALARM, HORN/SPEAKER, WEATHERPROOF.
STROBE. SUBSCRIPT INDICATES CANDELA RATING.
DETECTOR, HEAT.
DETECTOR, SMOKE, DUCT WITH HOUSING AND SAMPLING TUBE.
DETECTOR, SMOKE, ELEVATOR RECALL DESIGNATION.
DETECTOR, SMOKE, BEAM TRANSMITTER.
DETECTOR, SMOKE, BEAM RECEIVER.
DETECTOR, SMOKE.
MAGNETIC DOOR HOLDER.
SHUT DOWN RELAY: INSTALL RELAY IN CONTROL CIRCUITOF EQUIPMENT TO BE CONTROLLED IN THE EVENT OF AFIRE.
FIRE ALARM MANUAL PULL STATION.
MONITOR MODULE.
CONTROL MODULE.
FIRE ALARM NOTIFICATION POWER SUPPLY.
FIRE ALARM CONTROL PANEL, SEMI-RECESSED.
FIRE SYSTEM ANNUNCIATOR.
FIRE ALARM
75
75
75
75
FSD
SD
M
G
C
WP
75
E
BT
BR
R
P
MM
CM
FPS
FCP
FSA
AUTOMATIC DOOR CLOSERS: DOOR CLOSERS SHALL BEFURNISHED WITH DOOR HARDWARE AND CONNECTED TOBY FIRE ALARM INSTALLERS.
C
RELAY MODULE.RM
SPEAKER, 8".
PROJECTOR, CEILING MOUNTED.
SCREEN, PROJECTION, CEILING MOUNTED.
AUDIO/VISUAL OUTLET. HDMI UNLESS OTHERWISE NOTED.PROVIDE A/V CABLING BETWEEN INPUT AND OUTPUT RECEPTACLES.
MEDIA CONNECTION PLATE.
EQUIPMENT CABINET.
CALL SWITCH, INTERCOM.
SPEAKER, USER DEFINED.
SPEAKER, SURFACE.
SPEAKER, RECESSED.
SPEAKER, MASKING.
HORN, WEATHER RESISTANT.
HORN.
SPEAKER, EXISTING.
SPEAKER, BLIND MOUNT.
SPEAKER, 12".
SPEAKER, 6".
SPEAKER, 4".
SPEAKER, WALL MOUNTED.
SPEAKER, CEILING MOUNTED.
X
TECHNOLOGY SYSTEM CABLE. SEE SPECIFIC JOB
EQUIPMENT LIST FOR APPLICABLE DESIGNATIONS.
EXAMPLES:
C = CONTROL CABLE
G = GROUND CABLE, 10 AWG, 1 CONDUCTOR, GREEN INSULATED
L = LINE LEVEL CABLE
M = MICROPHONE CABLE
S = SPEAKER CABLE, 70 VOLT SYSTEM
Z = SPEAKER CABLE, 8 OHM SYSTEM
TECHNOLOGY SYSTEMS
S8
XX
SS
SR
SM
SHW
SH
SE
SB
S12
S6
S4
S#
S#
PANNING CAMERA TRANSVERSE ANGLE.
CCTV CAMERA WITH PAN, TILT AND ZOOM.
CCTV CAMERA/ENCLOSURE WITH LENS, TYPICAL. SEE SCHEDULE.
CCTV MONITOR.
CCTV HEADEND EQUIPMENT.
CCTV
360°
PTZ
M
CCTV
ULTRASONIC MOTION DETECTOR.
PASSIVE INFRARED SENSOR.
BELL.
REMOTE DOOR RELEASE BUTTON.RL
EXIT REQUEST.
DOOR SWITCH, BALANCED MAGNETIC CONTROL.
KEYPAD/CARD READER COMBINATION.
CARD READER.
CARD ACCESS DOOR TYPE #1 OR AS NOTED. SEE SCHEDULE.
INTRUSION DETECTION HEADEND EQUIPMENT.
SECURITY CONTROL PANEL.
SECURITY
U
IR
ER
KCR
CR
#1
SEC
CTR
CIRCUIT BREAKER, MOLDED CASE (ONE-LINE DIAGRAM).
CIRCUIT BREAKER SOLID STATE WITH LONG, SHORT,INSTANTANEOUS AND GROUND FAULT TRIP SETTING
CIRCUIT BREAKER SOLID STATE WITH LONG, SHORT &INSTANTANEOUS TRIP SETTING.
LSIG
LSI
RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUITINTERRUPTER, CONNECTED TO UPS: NEMA 5-20R.
RECEPTACLE, DUPLEX, TAMPER RESISTANT: NEMA 5-20R.T
SYMBOL DESCRIPTION PROTECTED SIDE ELEVATION UNPROTECTED SIDE ELEVATION LOCK TYPE(S) DIVISION OF WORK AND COMMENTS
TYPE 1
HARDWARE SETS:
1.W R2, 3.W R2
SINGLE DOOR, WIRELESS CARD
READER
(FREE EGRESS)
*HARDWARE BY 281300
WIRELESSMORTISE LOCKSET
SECURITY CONTRACTOR PROVIDES:
• WEL
HARDWARE CONTRACTOR PROVIDES:
• NONE
LOCK CONTROLLED BY:
• CR
TYPE 3
HARDWARE SETS:
7.0, 8.0
SINGLE DOOR, 1 CARDREADER,(FREE EGRESS)
ELECTRICLOCKSET
SECURITY CONTRACTOR PROVIDES:
• CR, L/PS, FH, DH
HARDWARE CONTRACTOR PROVIDES:
• EL, EPT
LOCK CONTROLLED BY:
• CR
TO ACS
TYPE 2
HARDWARE SETS:
5.W R2, 6.W R2
SINGLE DOOR, WIRELESS
CARD READER
(FREE EGRESS)
EM CLOSER WITH MOTION
DETECTOR
*HARDWARE BY 281300
WIRELESSMORTISE LOCKSET
SECURITY CONTRACTOR PROVIDES:
• WEL
HARDWARE CONTRACTOR PROVIDES:
• EM CLOSER
LOCK CONTROLLED BY:
• CR
TYPE 4
HARDWARE SET:
1.0
SINGLE DOOR, 1 CARD READER
WITH AUTO OPENER
CONTINUOUS HINGE POWER
TRANSFER
ELECTRIC EXITDEVICE WITHAUTO OPENER
TO ACS
SECURITY CONTRACTOR PROVIDES:
• CR, FH, DH, L/PS
HARDWARE CONTRACTOR PROVIDES:
• EED, EH, ADA
LOCK CONTROLLED BY:
• CR
TYPE 5 TO ACS
HARDWARE SET:
2.0
DOUBLE DOOR, 1 CARD READER(1 FIXED LEAF WITH AUTOOPENER)
(EGRESS SIDE)
ELECTRIC STRIKE SECURITY CONTRACTOR PROVIDES:
• CR, L/PS, FH, DH
HARDWARE CONTRACTOR PROVIDES:
• ES, EH
LOCK CONTROLLED BY:
• CR
TYPE 6
HARDWARE SETS:
3, 4
SINGLE DOOR, NETWORK CARD
READER
(FREE EGRESS)
FRAME POWER TRANSFER OR
CONTINUOUS HINGE
*HARDWARE BY 281300
ACCESS MORTISELOCKSET
SECURITY CONTRACTOR PROVIDES:
• AEL, FH, DH, L/PS
HARDWARE CONTRACTOR PROVIDES:
• EPT
LOCK CONTROLLED BY:
• CR
TO ACS
AUDIO-VIDEO SYSTEM EQUIPMENT LISTTHE ITEMS INDICATED BELOW SHALL NOT BE CONSTRUED AS A "BILL OF MATERIALS". THIS LIST IDENTIFIES ITEMS OF SIGNIFICANCE USED DURING THE DESIGN OFTHE ELECTRONIC SYSTEMS INSTALLATION. WHERE THE ITEMS INDICATED ARE ONE PORTION OF AN ASSEMBLY, THE ENTIRE ASSEMBLY SHALL BE PROVIDEDUNLESS SPECIFIED OTHERWISE. PROVIDE ALL MISCELLANEOUS HARDWARE AND SUPPORTS WHICH MAY NOT BE LISTED HERE, FOR A COMPLETE INSTALLATION.COMPARE CATALOG NUMBERS WITH DESCRIPTIONS AND NOTIFY ENGINEER OF DISCREPANCIES PRIOR TO BID. IF CATALOG NUMBERS DO NOT MATCHDESCRIPTIONS, THE DESCRIPTIONS TAKE PRECEDENCE. PROVIDE COMPLETE SUBMITTAL FOR APPROVAL PRIOR TO PURCHASING ANY EQUIPMENT OR CABLE.REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.