GENERAL NOTES All building work to be in accordance with National Building Regulations SANS 10400, SANS 204 as well as by-laws and requirements of Local Authority. All levels, heights and dimensions to be verified on site. Errors, discrepancies or omissions from these drawings must be reported to designer immediately. These drawings are not to be scaled and figured dimensions must be utilised. FOUNDATIONS All vegetable matter to be removed from within perimeter of building. Foundations taken down to depth in accordance with appointed Engineer's design. Concrete to be 10 MPa. Minimum depth 600mm. Size determined by Engineer. All soil compaction to Engineer's specification. Consolidated fill to be treated with ant poison. WALLS As per Part K of SANS 10400. Walls in accordance with Schedule 1 Table 2 and freestanding walls Schedule 1 Table 5 of NBR. Brickforce minimum every 6th course. No DPC to freestanding walls. Weepholes and expansion joints as necessary to freestanding walls. RC lintels over all openings. Painting and preparation to comply with manufacturer's specifications. DAMP PROOFING DPC to be a minimum of 150mm above ground level. DPM to be a minimum of 0.250mm thick. DPM to be on compacted fill. DPC to be provided to all window cills. STRUCTURE RC structure to be in accordance with appointed Structural Engineer's details. Monolithic components to be constructed in accordance with SABS 0100 or SABS 0145. CHIMNEYS & FIREPLACE Chimneys and fireplace in accordance with Part V of NBR. DRAINAGE All drainage works to be in accordance with Municipality drainage requirements. 100mm diameter UPVC sewer pipe drain with a minimum fall of 1:60. 100mm diameter OVP at head of drain. All drainage chased into walls to allow access to bends. Lintels to be built over drainage passing through walls and drainage to be encased in concrete sleeve where it passes under building. Foundations to be reinforced where passing over WP. IE's to be provided at maximum 24 metres centre to centre. Gullies to have a minimum of 150mm upstand all around. No bends or junctions under building. 1 metre concrete or brick apron around building where gutters are not provided. Provide rodding eyes at head of drain, to all changes of direction and at a maximum of 25m intervals. Provide inspection eyes at all junctions of drain. Inspection eyes to have marked covers at ground level. WP to bath, shower and sinks to be minimum 40mm diameter. WP to WHB and bidets to be minimum of 32mm diameter. All waste pipes to have 65mm reseal traps or vented traps to waste fittings 3m or longer. All showers to have brass traps. 450X450mm FC access panel to all drainage ducts. All soil fittings with vertical discharge greater than 1220mm to have anti syphon vent pipes. All piping from basins chased into brickwork to be inspected and approved by Council before covering up. ROOF Roof trusses manufactured in accordance with Part L Roofs of SANS 10400 or designed by Engineer in accordance with SANS 10160: Loading Code and SANS 10163: The Structural Use of Timber. Roof construction to conform to Part 1 Schedule 1 Table 1 of NBR with approved underlay. GS strap as anchorage to all roof trusses and wall plates. GS flashing as necessary. All waterproofing to manufacturer's specification. STAIRCASES & BALUSTRADES As per Part M of SANS 10400 and to comply to SABS requirements. Staircases to have treads minimum 250mm and risers maximum 200mm. Balustrades minimum 1000mm height and openings max 100mm. TIMBER All timber in accordance with SANS 0163. ALUMINIUM DOORS & WINDOWS In accordance with AAAMSA and SABS rules and requlations. GEYSER Geyser to SABS 0254 All exposed hot water piping to be insulated with min R- value of 1.0 GLAZING As per Part N of SANS 10400 and to comply to SABS requirements. 6.5mm PVC laminated safety glass to be used from 0 to +900mm affl. POOL SAFETY Pool Safety in accordance with SABS 1390 and Section 4 of NBR, including self closing and locking gate. TILING Aluminium trim to all tile edging. PAVING Paving apron of 1m wide to perimeter of building where gutters are not specified . HOUSEWORK 03.04 385 DU Elect Plan, H&C Water Layout and SANS Notes CELL: 082 457 2785 19 TUSCANY GROVE CAMPBELL ROAD, CRAIGAVON GAUTENG PO BOX 2324 FOURWAYS, SANDTON 2055 LESLIE & LINDA BOSMA ERF 8639 EASTFORD DOWNS, KNYSNA [email protected] HOT WATER SUPPLY GENERAL In order to comply with functional regulations XA2 Contained in Part XA of the NBR the following guidance is provided: Accordance with Table 2 and 5 of SANS 10252-1:2004. Requirements for water installation in buildings shall be in accordance with SANS 10252-1 and SANS 10254. All hot water service pipes shall be clad with insulation with a min R value in accordance with Table 1. Thermal insulation if any shall be installed in accordance with manufactures instructions. THERMAL INSULATION Pipes, fittings and components shall when necessary be protected against freezing. The insulation provided shall be appropriate to the min. temperature that can be expected in that geographical area. All exposed pipes to and from the hot water cylinders and central heating system shall be insulated with pipe insulation material with a thermal resistance in accordance with table 10. R value of 1.00 for 15mm pipes. Insulation shall be protected against the effects of weather and sunlight, and be able to withstand the temp. within the piping and achieve the min. total r value given in table 10: Table 10 Internal Dia of pipe >80 .......... Min R value < 80 ........................................ 1.00 >80 ......................................... 1.5 Hot water vessels and tanks shall be insulated with material that achieves a min r value of 2.0. Note: to achieve this value, insulation in addition to the manufacturer’s installed insulation might be required. Insulation on vessels, tanks and piping containing cooling water shall be protected by a vapour barrier on the outside of the insulation. The piping insulation requirements do not apply to space heating water piping located within the space being heated. Where the piping is to provide the heating to that space or encased within a concrete floor slab or in masonry, such piping shall comply with this Part of SANS. Piping to be insulated includes all flow and return cold water supply piping within 1m of the connection for the heating or cooling system and pressure relief piping within 1m of the connection to the heating or cooking system. Where possible the length of pipe runs shall be minimised. After thermal insulation material has been installed, the ingress of moisture into such material shall be prevented. Note that roughness increases the effective surface area of insulation material and consequently, heat losses and moisture increase the thermal conductivity of the material. HOT WATER SYSTEMS CALCULATION Calculated as per SANS 10252-1:2004 (hot water system to be endorsed by specialist): Type of accommodation: Dwelling / House Daily capacity in litres: 55 - 110 l/day Number of people per day: 4 Assumed daily water consumption in litres: 440 l/day Assumed daily hot water consumption in litres: 220 l/day Assumed annual hot water consumption in litres:80 300 litres Based on daily design occupancy 50% of daily hot water in litres: 110 l/day Provided by means other than electrical resistance heating Insulation Requirements Internal Dia of hot water service pipes: <80 Min R-value 1.0 as per SANS 204 Min R-value for hot water tanks 2.0 Insulation may be required Hot Water Calculation as per SANS 10252 - 1 Estimated daily demand for hot water: 110 l/day Capacity: 250 l storage tank All hot water pipes must be installed with thermal insulation of minimum R-value 1.0 Conclusion: The design complies with the requirements of SANS 10400 -XA-2011 and SANS 10252-1:2004 for hot water calculations ELECTRICAL NOTES ELECTRICAL Electrical layout to be checked on site by specialist before any work is put to hand All electrical components and installations to comply with relevant NBR and SANS. All plugs to be @ 350mm (centre line) from FFL unless specified otherwise. All light switches to be @ 1200mm (centre line) from FFL unless specified otherwise. Alarm system by specialist. Design and layout to approval of client. Sound system by specialist. Design and layout to approval of client. All fixtures, fittings and appliances must also be approved by client prior to installation and application. SERVICES All internal conduits for fibre optics, security or TV to be min Ø 25mm (unless specified larger), fitted with a draw wire, installed with slow bends and with a single / dedicated conduit per point. (No "daisy chaining" or looping of conduits is allowed). 2 x Ø25mm conduits to be provided to main TV point from DSTV aerial. (This is where the decoders will be situated / installed). All DSTV conduits to be chased or routed through ceiling voids to pts indicated. Should the TV be mounted at a high level at the main TV point, a Ø32mm conduit must be provided from the low TV point to the higher level point in order to accommodate the HDMI cable. Ensure that electrical plug points are provided at all TV, telephone (for digital phones) and data points. All electrical cabling and data / TV cabling to be installed in separate conduits with min 300mm distance between conduits and should cross at 90° angles where necessary. All internal cabling to be installed by approved and accredited installers. Telkom line to be trenched from boundary to tel points where indicated. DOOR & WINDOW NOTES All doors and windows to be in accordance with National Building Regulations SANS 10400, SANS 204 as well as all by-laws and requirements of the Local Authority. All external doors open outward except for main entrance doors TIMBER All timber in accordance with SANS 0163. ALUMINIUM DOORS & WINDOWS In accordance with AAAMSA and SABS rules and requlations. GLAZING As per Part N of SANS 10400 and to comply to SABS requirements. GLAZING 6.5mm PVC laminated safety glass to be used from 0 to +900mm affl. All external doors open outward except for main entrance doors. All external doors exposed to weather must include a bottom rail to frame. 40mm thk IsoBoard rigid insulation board 600mm width with IsoPine finish /edge bevelled finish fixed above trusses as ceiling. Paint with acrylic PVA (No solvent based paint) Col: TBC. Existing gypsum ceiling to remain. @1150 SH DSTV @1150 @1150 @1150 @1150 I (STOVE ISOLATOR) @1850 @1850 @1850 @1850 @1850 @3200 WI-FI 2W D D D 2W 2W 2W 2W DB 2W D @1150 D D DSTV WI-FI G @1850 Weatherproof wall mounted decorative external light fitting selected by client. Light must not be visible to neighbouring residents. Existing hot water storage in ceiling void. Electrician to check geyser complies with SABS 0254 and to ensure isolator switch and suitable power supply. Connect circuit to first floor 2-way switch Plug point for garage door motor flush with ceiling soffit. Make provision in concrete slab. 40mm thk IsoBoard rigid insulation board 600mm width with IsoPine finish /edge bevelled finish fixed above trusses as ceiling. Paint with acrylic PVA (No solvent based paint) Col: TBC. @1150 WI-FI SH G 2W EXTER DISH P UNDER New hot water storage heater (in ceiling void above bath) for flat panel solar collectors mounted on roof. Geyser to comply to SABS 0254. Electrician to ensure isolator switch and suitable power supply. Overflow pipe to lead outside. All exposed hot water piping to be insulated with min R-value of 1.0. Installation by certified plumber to follow manufacturer's spec. Connect circuit to ground floor 2-way switch External 8l gas water heater unit enclosed in fabricated weatherproof and ventilated structure and fixed to wall. No electrical point required. All ducting and pipes to be built into structure. All exposed hot water piping to be insulated with min R-value of 1.0 Existing hot water storage in ceiling void. Electrician to check geyser complies with SABS 0254 and to ensure isolator switch and suitable power supply. G Basin WM Cold water supply from municipal connection DW Sink WC Gas water heater Tap Tap Tap Basin WC Shwr Cold water supply to first floor WC Basin Shwr New hot water storage heater (in ceiling void above bath) for flat panel solar collectors mounted on roof. Geyser to comply to SABS 0254. Electrician to ensure isolator switch and suitable power supply. Hot water ring main (return line). Ø22 insulated (min R-value of 1.0) copper pipe ring main connected to solar panels on roof slab and hot water storage (geyser) in ceiling void. Connected as per SANS 10400-XA:2011. G Basin WC Bath Shwr Cold water supply from ground floor Hot water return 15A Waterproof single plug point @ 350 AFFL unless indicated otherwise. 15A Dedicated single plug point @ 350 AFFL unless indicated otherwise. [Typically for fridge / freezer or computer]. 3W LED Low Voltage outdoor garden lights with integrated transformer. 15A Double plug point @ 350 AFFL unless indicated otherwise. 15A Waterproof double plug point @ 350 AFFL unless indicated otherwise. Isolator switch @ 1200 AFFL unless indicated otherwise [for oven, hob, spa bath, etc]. Geyser point. 3W LED Low Voltage Downlights on track. Position transformer where shown [when the transformer is not integrated into fitting or track]. Heated towel rail electrical point [Isolator]. Telephone point @ 350 AFFL unless indicated otherwise. 2 Tube 1200 fluorescent lamp box fitting. Internet dedicated point @ 350 AFFL unless indicated otherwise. Intercom dedicated point @ 1200 AFFL unless indicated otherwise. TV aerial point @ 350 AFFL unless indicated otherwise. Cable to be ducted to aerial and dish position shown. LED strip lights fitted as continuous bulkhead lighting. 5W/lin.m. Transformer to be hidden. Speaker point in ceiling unless indicated otherwise. 2” X 4” Drawbox for Audio Controls @ 350 AFFL. AC wall unit “Artcool” 500 W X 400 H X 100 D. Requires drainage into existing WP or to outside wall [to approval of designer] as well as power. AC grilles mounted into ceiling or walls as indicated. CFL 5W GU10 recessed downlight lamp fitting (warm white). (Use dimmable lamps where required). Keypad for Security. Thermostat / switch for underfloor heating @ 1200 AFFL unless indicated otherwise. 230V dedicated power point. Passive eye / Sensor for Security. Switch in a 2 way circuit as shown @ 1200 AFFL unless indicated otherwise. Switch @ 1200 AFFL unless indicated otherwise. 230V power point for stock recessed foot light @ 350 AFFL unless indicated otherwise. 11W CFL lamp. Waterproof where used externally. 230V power point for decorative pendant light fitting. 15W CFL lamp. 15A Single plug point @ 350 AFFL unless indicated otherwise. Switch with dimmer @ 1200 AFFL unless indicated otherwise. 3W LED Low Voltage shockproof and waterproof uplighter recessed into floor. Integrated transformer. ELECTRICAL 3W LED Low Voltage Downlights on cables linked to transformer in position indicated. 230V power point for stock bulkhead wall mounted light fitting @ 1800 AFFL unless indicated otherwise. 15W CFL lamp. Waterproof where used externally. SEC AC AUDIO TV COM I T H G W D W W G TH 2W D SERVICES LEGEND 230V power point for stock bulkhead wall mounted light fitting @ 1800 AFFL unless indicated otherwise. 15W CFL lamp. Waterproof where used externally. 11W CFL Downlight CFL 5W GU10 spotlight lamp fitting (warm white). *Roof assembly to achieve a min R-Value of 3.7 as per SANS 204:2011. Roof structure to comply with part 'L' of SANS 10400 40mm thk IsoBoard rigid insulation board 600mm width with IsoPine/edge bevelled finish laid horizontally and secured as specified to top of trusses. Paint ceiling soffit with water based acrylic where Isopine exposed to view. SABS approved trusses and spacing to comply with part 'H' of SANS 10400 and as determined by Engineer. Pitch 17.5º. Waterproof sisalation membrane as underlay. Coro / Briti Cordova Terracotta roof tiles. Fix on 75X38 timber battens @ centres to suit and according to tile manufacturer's spec. 200x25mm (or closest to fit) timber fascia board - doubles as tilting fillet. 75x38 timber purlins @ centres to suit and according to roof tile and insulation board manufacturer's spec. Timber wall plate. 40mm thk Isotherm thermal blanket insulation. 38x38 timber counter battens to secure Isopine panels. Fixed directly over rafters. ROOF ASSEMBLY CALCULATION PITCH 17.5º / CATHEDRAL CEILING / CEMENT TILES Climate Zone Total required Resistivity (m 2 K/W) Direction 4 3.7 Up Outdoor air film (7m/s). (Ref: Table F.3) 0.03 Cement Roof Tile. (Ref: Table F.3) 0.02 Sisalation Sheet (Reflective Foil / Emissivity: 0,2 outer - 0,05 inner/ In non-ventilated roof space). (Ref: 4.3.6 Roof Assemblies Table 9) 0.75 Roof air space (non-reflective). (Ref: Table F.3) 0.18 75mm Aerolite Mineral Wool Insulation 1.88 40mm rigid EPS board Insulation 0.82 Indoor air film (still air). (Ref: Table F.3) 0.11 Total R-value is a combination of roof assembly and insulation 3.79 Conclusion: The design complies with the minimum requirements of SANS 10400- XA-2011 & SANS 204 EXTERNAL WALL CALCULATION Parameters Conclusion: The design complies with the minimum requirements of SANS 10400 -XA-2011 Min Thermal Resistivity R = 0.22 Climatic Zone 4 (λ) Thermal Conductivity (w/m²k) (l)Thickness (mm) Resistivity(m 2 K/W) External Plaster - 0 0.00 Brickwork 0.70 220 0.31 Internal Plaster - 15 0.00 TOTAL 235 0.31 PL03 Ground Reflected Ceiling and Electrical 1:100 PL04 First Reflected Ceiling and Elect 1:100 PL05 Ground Hot & Cold Water Layout 1:100 PL06 First Hot & Cold Water Layout 1:100 W-10 Truss Roof Detail 1:10 As Indicated EASTFORD DOWNS GUIDELINES It is noted that these plans have been prepared in accordance with the Building & Landscaping Guidelines for Eastford Downs. All building activity is bound to comply to the same rules as defined in the indicated document and all contractors and sub-contractors must ensure that they are familiar with the conditions described within the Building Code of Conduct before commencing work. B 2017.09.05 J. TRUDA SACAP REGISTRATION: T0321 LIGHTING ENERGY CONSUMPTION SCHEDULE DESCRIPTION QUANTITY TOTAL WATTS CFL 5W GU10 recessed downlight lamp fitting (warm white). (Use dimmable lamps where required). 33 off 165 W Pendant light compact fluorescent energy saving lamp 15W 10 off 150 W Wall Mounted Light compact fluorescent energy saving lamp 15W 8 off 120 W TOTAL 435 W/1000 0.435 kW Allowed: 5.0 kWh/m².a Area of Structure: 376.04 m² 5.0 kWh/m².a X 376.04 m² = 1 880 kWh.a Assume the lights are turned on between 17:30-21:00 each day: That is the following number of hours per day: 3.5 hrs/day 52 weeks X 7 days X 3.5 hrs/day = 1 274 hrs/annum 0.435 kW X 1 274 hrs/annum = 554 kWh.a (<1655kWh.a) Therefore structure complies with Part ‘O’ of SANS 10400
1

ROOF ASSEMBLY CALCULATION - Knysna · accordance with SANS 10160: Loading Code and SANS 10163: The Structural Use of Timber. Roof construction to conform to Part 1 Schedule 1 Table

Feb 08, 2019

Download

Documents

phamduong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ROOF ASSEMBLY CALCULATION - Knysna · accordance with SANS 10160: Loading Code and SANS 10163: The Structural Use of Timber. Roof construction to conform to Part 1 Schedule 1 Table

GENERAL NOTES

All building work to be in accordance with National Building Regulations SANS 10400, SANS 204 as well as by-laws and requirements of Local Authority.All levels, heights and dimensions to be verified on site.Errors, discrepancies or omissions from these drawings must be reported to designer immediately.These drawings are not to be scaled and figured dimensions must be utilised.FOUNDATIONSAll vegetable matter to be removed from within perimeter of building.Foundations taken down to depth in accordance with appointed Engineer's design.Concrete to be 10 MPa. Minimum depth 600mm. Size determined by Engineer.All soil compaction to Engineer's specification.Consolidated fill to be treated with ant poison.WALLSAs per Part K of SANS 10400.Walls in accordance with Schedule 1 Table 2 and freestanding walls Schedule 1 Table 5 of NBR.Brickforce minimum every 6th course.No DPC to freestanding walls.Weepholes and expansion joints as necessary to freestanding walls.RC lintels over all openings.Painting and preparation to comply with manufacturer's specifications.DAMP PROOFINGDPC to be a minimum of 150mm above ground level.DPM to be a minimum of 0.250mm thick.DPM to be on compacted fill.DPC to be provided to all window cills.STRUCTURERC structure to be in accordance with appointed Structural Engineer's details.Monolithic components to be constructed in accordance with SABS 0100 or SABS 0145.CHIMNEYS & FIREPLACEChimneys and fireplace in accordance with Part V of NBR.DRAINAGEAll drainage works to be in accordance with Municipality drainage requirements.100mm diameter UPVC sewer pipe drain with a minimum fall of 1:60.100mm diameter OVP at head of drain.All drainage chased into walls to allow access to bends.Lintels to be built over drainage passing through walls and drainage to be encased in concrete sleeve where it passes under building. Foundations to be reinforced where passing over WP.IE's to be provided at maximum 24 metres centre to centre.Gullies to have a minimum of 150mm upstand all around.No bends or junctions under building.1 metre concrete or brick apron around building where gutters are not provided.Provide rodding eyes at head of drain, to all changes of direction and at a maximum of 25m intervals.Provide inspection eyes at all junctions of drain. Inspection eyes to have marked covers at ground level.WP to bath, shower and sinks to be minimum 40mm diameter. WP to WHB and bidets to be minimum of 32mm diameter.All waste pipes to have 65mm reseal traps or vented traps to waste fittings 3m or longer.All showers to have brass traps.450X450mm FC access panel to all drainage ducts.All soil fittings with vertical discharge greater than 1220mm to have anti syphon vent pipes.All piping from basins chased into brickwork to be inspected and approved by Council before covering up.ROOFRoof trusses manufactured in accordance with Part L Roofs of SANS 10400 or designed by Engineer in accordance with SANS 10160: Loading Code and SANS 10163: The Structural Use of Timber.Roof construction to conform to Part 1 Schedule 1 Table 1 of NBR with approved underlay.GS strap as anchorage to all roof trusses and wall plates.GS flashing as necessary.All waterproofing to manufacturer's specification.STAIRCASES & BALUSTRADESAs per Part M of SANS 10400 and to comply to SABS requirements.Staircases to have treads minimum 250mm and risers maximum 200mm.Balustrades minimum 1000mm height and openings max 100mm.TIMBERAll timber in accordance with SANS 0163.ALUMINIUM DOORS & WINDOWSIn accordance with AAAMSA and SABS rules and requlations.GEYSERGeyser to SABS 0254All exposed hot water piping to be insulated with min R-value of 1.0GLAZINGAs per Part N of SANS 10400 and to comply to SABS requirements.6.5mm PVC laminated safety glass to be used from 0 to +900mm affl.POOL SAFETYPool Safety in accordance with SABS 1390 and Section 4 of NBR, including self closing and locking gate.TILINGAluminium trim to all tile edging.PAVINGPaving apron of 1m wide to perimeter of building where gutters are not specified .

HOUSEWORK

03.04385

DU

Elect Plan, H&C Water Layout and SANSNotes

CELL: 082 457 2785

19 TUSCANY GROVECAMPBELL ROAD, CRAIGAVONGAUTENG

PO B

OX

2324

FOU

RWAY

S, S

AND

TON

2055

LESLIE & LINDA BOSMA

ERF 8639 EASTFORD DOWNS,KNYSNA

diet

er@

hous

ewor

k.jo

burg

HOT WATER SUPPLY

GENERALIn order to comply with functional regulations XA2 Contained in Part XA of the NBR the following guidance is provided: Accordance with Table 2 and 5 of SANS 10252-1:2004.Requirements for water installation in buildings shall be in accordance with SANS 10252-1 and SANS 10254.All hot water service pipes shall be clad with insulation with a min R value in accordance with Table 1.Thermal insulation if any shall be installed in accordance with manufactures instructions.

THERMAL INSULATIONPipes, fittings and components shall when necessary be protected against freezing. The insulation provided shall be appropriate to the min. temperature that can be expected in that geographical area.All exposed pipes to and from the hot water cylinders and central heating system shall be insulated with pipe insulation material with a thermal resistance in accordance with table 10. R value of 1.00 for 15mm pipes.Insulation shall be protected against the effects of weather and sunlight, and be able to withstand the temp. within the piping and achieve the min. total r value given in table 10:Table 10Internal Dia of pipe >80 .......... Min R value< 80 ........................................ 1.00>80 ......................................... 1.5Hot water vessels and tanks shall be insulated with material that achieves a min r value of 2.0. Note: to achieve this value, insulation in addition to the manufacturer’s installed insulation might be required.Insulation on vessels, tanks and piping containing cooling water shall be protected by a vapour barrier on the outside of the insulation.The piping insulation requirements do not apply to space heating water piping located within the space being heated. Where the piping is to provide the heating to that space or encased within a concrete floor slab or in masonry, such piping shall comply with this Part of SANS.Piping to be insulated includes all flow and return cold water supply piping within 1m of the connection for the heating or cooling system and pressure relief piping within 1m of the connection to the heating or cooking system. Where possible the length of pipe runs shall be minimised.After thermal insulation material has been installed, the ingress of moisture into such material shall be prevented. Note that roughness increases the effective surface area of insulation material and consequently, heat losses and moisture increase the thermal conductivity of the material.

HOT WATER SYSTEMS CALCULATIONCalculated as per SANS 10252-1:2004 (hot water system to be endorsed by specialist):

Type of accommodation: Dwelling / House

Daily capacity in litres: 55 - 110 l/day

Number of people per day: 4

Assumed daily water consumption in litres: 440 l/day

Assumed daily hot water consumption in litres: 220 l/day

Assumed annual hot water consumption in litres:80 300 litres Based on daily design occupancy

50% of daily hot water in litres: 110 l/dayProvided by means other than electrical resistance heating

Insulation Requirements

Internal Dia of hot water service pipes: <80

Min R-value 1.0 as per SANS 204

Min R-value for hot water tanks 2.0 Insulation may be required

Hot Water Calculation as per SANS 10252 - 1

Estimated daily demand for hot water: 110 l/day

Capacity: 250 l storage tank

All hot water pipes must be installed with thermal insulation of minimum R-value 1.0

Conclusion: The design complies with the requirements of SANS 10400 -XA-2011 and SANS 10252-1:2004 for hot water calculations

ELECTRICAL NOTES

ELECTRICAL Electrical layout to be checked on site by specialist before any work is put to handAll electrical components and installations to comply with relevant NBR and SANS.All plugs to be @ 350mm (centre line) from FFL unless specified otherwise.All light switches to be @ 1200mm (centre line) from FFL unless specified otherwise.Alarm system by specialist. Design and layout to approval of client.Sound system by specialist. Design and layout to approval of client.All fixtures, fittings and appliances must also be approved by client prior to installation and application.SERVICESAll internal conduits for fibre optics, security or TV to be min Ø 25mm (unless specified larger), fitted with a draw wire, installed with slow bends and with a single / dedicated conduit per point. (No "daisy chaining" or looping of conduits is allowed).2 x Ø25mm conduits to be provided to main TV point from DSTV aerial. (This is where the decoders will be situated / installed).All DSTV conduits to be chased or routed through ceiling voids to pts indicated.Should the TV be mounted at a high level at the main TV point, a Ø32mm conduit must be provided from the low TV point to the higher level point in order to accommodate the HDMI cable.Ensure that electrical plug points are provided at all TV, telephone (for digital phones) and data points.All electrical cabling and data / TV cabling to be installed in separate conduits with min 300mm distance between conduits and should cross at 90° angles where necessary.All internal cabling to be installed by approved and accredited installers.Telkom line to be trenched from boundary to tel points where indicated.

DOOR & WINDOW NOTES

All doors and windows to be in accordance with National Building Regulations SANS 10400, SANS 204 as well as all by-laws and requirements of the Local Authority.All external doors open outward except for main entrance doorsTIMBERAll timber in accordance with SANS 0163.ALUMINIUM DOORS & WINDOWSIn accordance with AAAMSA and SABS rules and requlations.GLAZINGAs per Part N of SANS 10400 and to comply to SABS requirements.GLAZING6.5mm PVC laminated safety glass to be used from 0 to +900mm affl.All external doors open outward except for main entrance doors.All external doors exposed to weather must include a bottom rail to frame.

40mm

thk I

soBo

ard rig

id ins

ulatio

n boa

rd 60

0mm

width

with I

soPin

e finis

h /ed

ge be

velle

dfin

ish fix

ed ab

ove t

russe

s as c

eiling

. Pain

t with

acryl

ic PV

A (No

solve

nt ba

sed p

aint) C

ol: TB

C.

Exist

ing gy

psum

ceilin

g to r

emain

.

@11

50

SH

DST

V@1150

@1150

@11

50

@11

50

I (STOVE ISOLATOR)@1850

@1850

@18

50

@18

50

@18

50

@32

00

WI-F

I

2WD

DD 2W

2W

2W

2W

DB

2WD

@1150

DD

DST

VW

I-FI

G

@18

50

Weath

erproo

f wall

mou

nted d

ecora

tive e

xterna

l light

fitting

selec

ted by

clien

t. Ligh

t mus

t not

be vi

sible

to ne

ighbo

uring

resid

ents.

Exist

ing ho

t wate

r stor

age i

n ceil

ing vo

id. El

ectric

ian to

chec

k gey

ser c

ompli

es w

ith SA

BS02

54 an

d to e

nsure

isola

tor sw

itch a

nd su

itable

powe

r sup

ply.

Connectcircuit to firstfloor 2-way

switch

Plug point forgarage doormotor flushwith ceilingsoffit. Makeprovision in

concrete slab.

40mm

thk I

soBo

ard rig

id ins

ulatio

n boa

rd 60

0mm

width

with I

soPin

e finis

h /ed

ge be

velle

dfin

ish fix

ed ab

ove t

russe

s as c

eiling

. Pain

t with

acryl

ic PV

A (No

solve

nt ba

sed p

aint) C

ol: TB

C.

@11

50

WI-F

I

SH

G

2W

EXTERNAL SATDISH POINTUNDER EAVES

New

hot w

ater s

torag

e hea

ter (in

ceilin

g void

abov

e bath

) for fl

at pa

nel s

olar c

ollec

tors

moun

ted on

roof.

Gey

ser to

comp

ly to

SABS

0254

. Elec

trician

to en

sure

isolat

or sw

itch a

ndsu

itable

powe

r sup

ply. O

verflo

w pip

e to l

ead o

utside

. All e

xpos

ed ho

t wate

r pipi

ng to

beins

ulated

with

min

R-va

lue of

1.0.

Instal

lation

by ce

rtified

plum

ber to

follo

w ma

nufac

turer'

ssp

ec.

Connectcircuit to

ground floor2-way switch

Exter

nal 8

l gas

wate

r hea

ter un

it enc

losed

in fa

brica

ted w

eathe

rproo

f and

venti

lated

struc

ture a

nd fix

ed to

wall

. No e

lectric

al po

int re

quire

d. All

ducti

ng an

d pipe

s to b

e buil

t into

struc

ture.

All ex

pose

d hot

water

pipin

g to b

e ins

ulated

with

min

R-va

lue of

1.0

Exist

ing ho

t wate

r stor

age i

n ceil

ing vo

id. El

ectric

ian to

chec

k gey

ser c

ompli

es w

ith SA

BS02

54 an

d to e

nsure

isola

tor sw

itch a

nd su

itable

powe

r sup

ply.

G

Basin

WM

Cold watersupply frommunicipal

connection

DW

Sink

WC

Gas

wat

er h

eate

r

Tap

Tap

Tap

Basi

n

WC

Shwr

Cold watersupply tofirst floor

WC

Basin

Shwr

New

hot w

ater s

torag

e hea

ter (in

ceilin

g void

abov

e bath

) for fl

at pa

nel s

olar c

ollec

tors

moun

ted on

roof.

Gey

ser to

comp

ly to

SABS

0254

. Elec

trician

to en

sure

isolat

or sw

itch a

ndsu

itable

powe

r sup

ply.

Hot w

ater ri

ng m

ain (re

turn l

ine). Ø

22 in

sulat

ed (m

in R-

value

of 1.

0) co

pper

pipe r

ing m

ainco

nnec

ted to

solar

pane

ls on

roof

slab a

nd ho

t wate

r stor

age (

geys

er) in

ceilin

g void

.Co

nnec

ted as

per S

ANS 1

0400

-XA:2

011.

GBasi

n

WC Bath

Shw

r

Cold watersupply fromground floor

Hot waterreturn

15A Waterproof single plug point @ 350 AFFL unlessindicated otherwise.

15A Dedicated single plug point @ 350 AFFL unlessindicated otherwise. [Typically for fridge / freezer orcomputer].

3W LED Low Voltage outdoor garden lights withintegrated transformer.

15A Double plug point @ 350 AFFL unless indicatedotherwise.

15A Waterproof double plug point @ 350 AFFL unlessindicated otherwise.

Isolator switch @ 1200 AFFL unless indicated otherwise[for oven, hob, spa bath, etc].

Geyser point.

3W LED Low Voltage Downlights on track. Positiontransformer where shown [when the transformer isnot integrated into fitting or track].

Heated towel rail electrical point [Isolator].

Telephone point @ 350 AFFL unless indicated otherwise.

2 Tube 1200 fluorescent lamp box fitting.

Internet dedicated point @ 350 AFFL unless indicatedotherwise.

Intercom dedicated point @ 1200 AFFL unless indicatedotherwise.

TV aerial point @ 350 AFFL unless indicated otherwise.Cable to be ducted to aerial and dish position shown.

LED strip lights fitted as continuous bulkheadlighting. 5W/lin.m. Transformer to be hidden.

Speaker point in ceiling unless indicated otherwise.

2” X 4” Drawbox for Audio Controls @ 350 AFFL.

AC wall unit “Artcool” 500 W X 400 H X 100 D. Requiresdrainage into existing WP or to outside wall [to approvalof designer] as well as power.

AC grilles mounted into ceiling or walls as indicated.

CFL 5W GU10 recessed downlight lamp fitting (warmwhite). (Use dimmable lamps where required).

Keypad for Security.

Thermostat / switch for underfloor heating @ 1200 AFFLunless indicated otherwise.

230V dedicated power point.

Passive eye / Sensor for Security.

Switch in a 2 way circuit as shown @ 1200 AFFL unlessindicated otherwise.

Switch @ 1200 AFFL unless indicated otherwise.

230V power point for stock recessed foot light @350 AFFL unless indicated otherwise. 11W CFLlamp. Waterproof where used externally.

230V power point for decorative pendant light fitting.15W CFL lamp.

15A Single plug point @ 350 AFFL unless indicatedotherwise.

Switch with dimmer @ 1200 AFFL unless indicatedotherwise.

3W LED Low Voltage shockproof and waterproofuplighter recessed into floor. Integrated transformer.

ELECTRICAL

3W LED Low Voltage Downlights on cables linked totransformer in position indicated.

230V power point for stock bulkhead wall mountedlight fitting @ 1800 AFFL unless indicated otherwise.15W CFL lamp. Waterproof where used externally.

SEC

AC

AUDIO

TV

COM

I

T

H

G

W

D

W

W

G

TH

2W

D

SERVICES LEGEND

230V power point for stock bulkhead wall mountedlight fitting @ 1800 AFFL unless indicated otherwise.15W CFL lamp. Waterproof where used externally.

11W CFL Downlight

CFL 5W GU10 spotlight lamp fitting (warm white).

*Roof assembly to achieve a min R-Valueof 3.7 as per SANS 204:2011. Roof

structure to comply with part 'L' of SANS10400

40mm

thk I

soBo

ard rig

id ins

ulatio

n boa

rd 60

0mm

width

with I

soPin

e/edg

e bev

elled

finish

laid h

orizo

ntally

and s

ecure

d as s

pecifi

ed to

top o

f trus

ses.

Paint

ceilin

g soffi

t with

wate

rba

sed a

crylic

where

Isop

ine ex

pose

d to v

iew.

SABS

appro

ved t

russe

s and

spac

ing to

comp

ly wit

h part

'H' o

f SAN

S 104

00 an

d as

deter

mine

d by E

ngine

er. Pi

tch 17

.5º.

Water

proof

sisala

tion m

embra

ne as

unde

rlay.

Coro

/ Briti

Cord

ova T

errac

otta r

oof ti

les. F

ix on

75X3

8 tim

ber b

atten

s @ ce

ntres

to su

it and

acco

rding

to til

e man

ufactu

rer's

spec

.

200x

25mm

(or c

loses

t to fit

) timb

er fas

cia bo

ard - d

ouble

s as t

ilting fi

llet.

75x3

8 tim

ber p

urlins

@ ce

ntres

to su

it and

acco

rding

to ro

of tile

and i

nsula

tion b

oard

manu

factur

er's s

pec.

Timbe

r wall

plate

.

40mm

thk I

sothe

rm th

ermal

blank

et ins

ulatio

n.

38x3

8 tim

ber c

ounte

r batt

ens t

o sec

ure Is

opine

pane

ls. Fi

xed d

irectl

y ove

r rafte

rs.

ROOF ASSEMBLY CALCULATION

PITCH 17.5º /CATHEDRAL CEILING / CEMENT TILES

Climate Zone Total required Resistivity (m2K/W) Direction

4 3.7 Up

Outdoor air film (7m/s). (Ref: Table F.3) 0.03

Cement Roof Tile. (Ref: Table F.3) 0.02Sisalation Sheet (Reflective Foil / Emissivity: 0,2 outer - 0,05 inner/ In non-ventilated roof space). (Ref: 4.3.6 Roof Assemblies Table 9)

0.75

Roof air space (non-reflective). (Ref: Table F.3) 0.18

75mm Aerolite Mineral Wool Insulation 1.88

40mm rigid EPS board Insulation 0.82

Indoor air film (still air). (Ref: Table F.3) 0.11

Total R-value is a combination of roof assembly and insulation 3.79

Conclusion: The design complies with the minimum requirements of SANS 10400-XA-2011 & SANS 204

EXTERNAL WALL CALCULATIONParameters Conclusion: The design complies with

the minimum requirements of SANS 10400 -XA-2011

Min Thermal Resistivity R = 0.22Climatic Zone 4

(λ) Thermal Conductivity (w/m²k) (l)Thickness (mm) Resistivity(m2K/W)

External Plaster - 0 0.00Brickwork 0.70 220 0.31Internal Plaster - 15 0.00TOTAL 235 0.31

PL03 Ground Reflected Ceiling and Electrical 1:100 PL04 First Reflected Ceiling and Elect 1:100

PL05 Ground Hot & Cold Water Layout 1:100 PL06 First Hot & Cold Water Layout 1:100

W-10 Truss Roof Detail 1:10

As Indicated

EASTFORD DOWNS GUIDELINESIt is noted that these plans have been prepared in

accordance with the Building & LandscapingGuidelines for Eastford Downs.

All building activity is bound to comply to the samerules as defined in the indicated document and all

contractors and sub-contractors must ensure that theyare familiar with the conditions described within theBuilding Code of Conduct before commencing work.

B

2017.09.05

J. TRUDASACAP REGISTRATION: T0321

LIGHTING ENERGY CONSUMPTION SCHEDULEDESCRIPTION QUANTITY TOTAL WATTS

CFL 5W GU10 recessed downlight lamp fitting (warm white). (Use dimmable lamps where required). 33 off 165 W

Pendant light compact fluorescent energy saving lamp 15W 10 off 150 W

Wall Mounted Light compact fluorescent energy saving lamp 15W 8 off 120 W

TOTAL435 W/1000

0.435 kW

Allowed: 5.0 kWh/m².a

Area of Structure: 376.04 m²

5.0 kWh/m².a X 376.04 m² = 1 880 kWh.a

Assume the lights are turned on between 17:30-21:00 each day:

That is the following number of hours per day: 3.5 hrs/day

52 weeks X 7 days X 3.5 hrs/day = 1 274 hrs/annum

0.435 kW X 1 274 hrs/annum = 554 kWh.a (<1655kWh.a)

Therefore structure complies with Part ‘O’ of SANS 10400