ROLLING STOCK CABLES GLOBAL CABLE EXPERTISE FOR ROLLING STOCK 2017 Nexans China 2305B-2310A, Westgate Tower, 1038 West Nanjing Road, Shanghai 200041 Tel:+86 512 8817 1200 Fax:+86 512 8817 1220 Email: [email protected]官方微信:Nexans 中国 官方微博:耐克森中国 网址:www.nexans.com / www.nexans.cn Ref. code: NSH 0018 EN-02/17 Copyright@Feb. 2017 - Nexans
100
Embed
ROLLING STOCK CABLES GLOBAL CABLE EXPERTISE FOR … · 2018. 5. 24. · The rolling stock industry, especially in China, is now at a crucial point in its development. New challenges
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
ROLLING STOCK CABLES GLOBAL CABLE EXPERTISE FOR ROLLING STOCK 2017
This catalogue shows a general description of products which characteristics are not contratual in any case.
NEXANS reserves the right to change specifications without prior notice.
All total or partial reproduction, done without NEXANS authorization is unlawful.
Page 1 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Part 4 Fire Resistant CablesFire resistant Single core cables
Part 5 Data cablesData bus TCN cables
Network cables Ethernet cables
Part 6 Roof cablesRoof cable
Technical dataConductors for power cables EN cables current rating EN cables short circuit current rating
2
568
2526
293036
43 44
4950
555660
636364
6768
71 72
7576
8182
86
8990
9394 95 98
Page 2 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Part1 & Part 2-1,2-4 & Part 4Single and multi core power cables and circuit integrity
cables
Part 1 & Part 4Low voltage cables and fire
resistant cables
Part 3Motor connection jumper
cables
Part 3Jumper cables between cars
Part 2-2 & Part 2-3High and extra hightemperature cables
Part 5Data bus cables for multimedia
transmission
Part 5Data bus cables for digital
transmission
Global cable expertise for rolling stock
Page 3 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Wide range of cables covering diverse railway standardsThe rolling stock industry, especially in China, is now at a crucial point in its development. New challenges must be met due to long-awaited equipment upgrades, booming high-speed train projects, and the growing need for conventional subways, full-automated metros, tramways and light-rail suburban vehicles.
The market for railway cables is characterized by the multitude of international, national and company-specific regulations. Furthermore, customer requirements are not all the same.
As a worldwide supplier of communication and energy cables for rolling stock, Nexans is continuing to develop safer and more efficient products that conform to diverse railway standards, and to meet the demand for train interoperability. Innovation, custom engineering and full outsource subsystem responsibility are among our service priorities.
Nexans wide product offer includes low voltage control cables, jumper cables, HV roof cables, coaxial cables for HF transmissions, data bus cables for multimedia and digital transmissions, low and high temperature power cables.
Nexans rolling stock productsAs a full provider of railway cables, Nexans has a complete product range suitable for all applications.
• Halogen free low-voltage wires• Halogen free medium-voltage wires for 6kV and 30kV voltage ranges• Halogen free single and multi core wiring cables for internal wiring up to 1 kV• Halogen free electronic and bus cables• Wires with circuit integrity performance in case of fire• Jumper cables• Wires with integral connectors and system technology• Customer-specific solutions
Cable operating voltageNominal voltage: U0/U (Um)U0: r.m.s value between a phase conductor and earth.U: r.m.s. value between phase conductors of a multi core cable or a system of single core cables.Um: highest constant permissible operating voltage. Um: U + 10 % for U < 1 kV, Um: U + 20 % for U ≥ 1 kVV0 = 1.5 U0, V0: direct voltage between insulated conductors and earth
ROHS and REACH complianceAll products in this catalogue do not contain any hazardous substance in accordance with the European
Directive n°2002/95/CE is relating to the removal of hazardous substances in the electrics and electronics equipments.
Page 4 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans China was s certified IRIS certification the quality management system in the railway industry, and passed the full test and approval of China Railway Test & Certification Centre (CRCC).
Page 5 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Part 1Low voltage control cables for rolling stock
Low
vol
tage
cont
rol c
able
s
Page 6 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
EN 50306-2Single core wires, thin wall insulation.They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered.
EN 50306-3Screened 1 to 4 core cables, thin wall insulation, thin wall sheath.They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered.
EN 50306-4Multi core and multi pair cables, thin wall insulation and standard wall sheath, screened, unscreened or individually screened of each pair.
Class P cables (minimum thickness of sheath 0.42 mm) are specified for use in PROTECTED situations.Class E cables (minimum thickness of sheath 1.0 mm) are specified for use in EXPOSED situations.
Scope of EN 50306 cables
Nexans EN 50306 TypesSinglecore
cables
Multcore
cables
Multipair
cables
Multi pair withOverall
screened(TC)
Min. thicknessof outer sheath
PageOverall screen and
sheath
Individual screen and
sheath
EN 50306-2 300VCategory M ● 9
EN 50306-3Category MM ● ● 0.20mm 10
EN 50306-4 Table1 Class P Category MM ● 0.42mm 11
EN 50306-4 Table1 Class E Category MM ● 1.00mm 12
EN 50306-4 Table3 Class P Category MM ● ● 0.42mm 13
EN 50306-4 Table3 Class E Category MM ● ● 1.00mm 14
EN 50306-4 Table5 Class P Category MMM ● ● 0.56mm 15
EN 50306-4 Table5 Class E Category MMM ● ● 1.00mm 16
EN 50306-4 Class P Category MM ● ● ● 0.42mm 17
EN 50306-4 Class E Category MM ● ● ● 1.00mm 18
FLAMEX SH20 600VCategory M ● 21
Page 7 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
EN 50306 insulation and sheath classificationAccording to the table below, M (single core), MM (multi core) or MMM (multi pair individually sheathed) category is the highest operating hazard level for insulation, inner sheath and outer sheath of EN 50306 cables.
Hazard level (HL) 1 2 or 3 4
Smoke (Light transmittance) — ≥ 60% ≥ 70%
Toxicity (Insulation) — ≤ 10 ≤ 6
Toxicity (Sheath) — ≤ 5 ≤ 3
Low temperature (-25°C ) / Oil resistant (IRM 902) A B C
Extra low temperature (-40°C ) / Oil resistant (IRM 902) D E F
Low temperature (-25°C ) / Extra oil and fuel resistant(IRM 902 + IRM 903) G H J
Extra low temperature (-40°C ) / Extra oil and fuel resistant(IRM 902 + IRM 903) K L M
Nexans EN 50306
HL 3 according to EN 45545-2: 2013
Low
vol
tage
cont
rol c
able
s
Page 8 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
According to EN 50306(See notes under technical data for details)
Standards
EN 45545-2 / BS 6853 / UNI CEI 11170-3
Thin wall insulated cablesFLAMEX® types300V
ApplicationsStrictly halogen free, all these wires and cables combine the advantages of thin wall thickness, small size, lightweight, high mechanical properties, and high chemical resistance. They are recommended for installation in railway vehicles, switching stations and control panels.
2. Insulation Special halogen free, thin wall Compound type SH20 Color: White
3. Screen Tinned copper wires braid
4. Sheath Special cross-linked HFFR Color: Black
FLA
MEX
EN
503
06-4
Tab.
3
FLA
MEX
EN
503
06-4
Tab.
5
FLA
MEX
EN
503
06-2
M
FLA
MEX
EN
503
06-4
Tab.
1
1
2
4
FLA
MEX
EN
503
06-4
Tab.
3
FLA
MEX
EN
503
06-4
Tab.
5
FLA
MEX
EN
503
06-2
M
FLA
MEX
EN
503
06-4
Tab.
1
3
4
AmbientTemperature-40°C to 100°C
GoodResistanceto UV & humidity
Goodchemicalresistance
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
EN 50306
Page 9 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
EN 50306-2Single core wires, unscreened and unsheathedTechnical data
TYPE NO.
Description
ConductorMin.
insulationthickness
Overall Ø
Average Weight
Fireload Inventory
Old New
Cross section
Max. diameter
n x ø R20 Min. Max.
mm2 mm Ω/km mm mm mm kg/km MJ/km
5000119900 50501010100100 EN 50306-2 300V 1x0.50 M 0.50 0.95 40.10 0.18 1.15 1.45 6 22 √
5000121800 50501010100200 EN 50306-2 300V 1x0.75 M 0.75 1.15 26.70 0.18 1.35 1.65 8 27 √
5000120000 50501010100300 EN 50306-2 300V 1x1.00 M 1.00 1.30 20.00 0.18 1.45 1.80 11 30 √
5000121900 50501010100400 EN 50306-2 300V 1x1.50 M 1.50 1.65 13.70 0.22 1.95 2.30 17 52 √
5000121000 50501010100500 EN 50306-2 300V 1x2.50 M 2.50 2.15 8.21 0.28 2.50 2.85 29 74 √
Note: 1. EN 50306-2 wires are base cores for EN 50306-3 and EN 50306-4 cables 2. Other colors on request 3. Marking: FLAMEX® 448 EN 50306-2 300V 1x《Section》M YY MM DD
Low
vol
tage
cont
rol c
able
s
Page 10 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
EN 50306-3Thin wall insulation, thin wall sheath, overall screened, 1 to 4 cores. Technical data
TYPE NO.
DesignationCross
section Min.
thickness of sheath
Overall Ø Average Weight
Fireload Inventory
Old NewMin. Max.
mm2 mm mm mm kg/km MJ/km
5000122000 50501020100100 EN 50306-3 300V 1x0.50 MM S 1x0.5 0.2 2.3 2.8 15 71 —
5000213600 50501020200100 EN 50306-3 300V 2x0.50 MM S 2x0.5 0.2 3.5 4.3 30 126 √
5000308000 50501020300100 EN 50306-3 300V 3x0.50 MM S 3x0.5 0.2 3.7 4.5 37 159 —
5000413300 50501020400100 EN 50306-3 300V 4x0.50 MM S 4x0.5 0.2 4.0 5.0 47 194 —
5000122100 50501020100200 EN 50306-3 300V 1x0.75 MM S 1x0.75 0.2 2.5 3.0 18 82 —
5000213700 50501020200200 EN 50306-3 300V 2x0.75 MM S 2x0.75 0.2 3.9 4.7 34 145 —
5000308100 50501020300200 EN 50306-3 300V 3x0.75 MM S 3x0.75 0.2 4.0 5.0 43 192 —
5000413400 50501020400200 EN 50306-3 300V 4x0.75 MM S 4x0.75 0.2 4.5 5.5 54 219 —
5000122200 50501020100300 EN 50306-3 300V 1x1.00 MM S 1x1.0 0.2 2.7 3.2 21 88 —
5000213800 50501020200300 EN 50306-3 300V 2x1.00 MM S 2x1.0 0.2 4.2 5.2 40 150 √
5000308200 50501020300300 EN 50306-3 300V 3x1.00 MM S 3x1.0 0.2 4.5 5.5 52 192 —
5000413200 50501020400300 EN 50306-3 300V 4x1.00 MM S 4x1.0 0.2 5.0 6.0 64 230 —
5000122300 50501020100400 EN 50306-3 300V 1x1.50 MM S 1x1.5 0.2 3.1 3.6 29 118 —
5000213900 50501020200400 EN 50306-3 300V 2x1.50 MM S 2x1.5 0.2 5.1 6.1 67 213 √
5000308300 50501020300400 EN 50306-3 300V 3x1.50 MM S 3x1.5 0.2 5.4 6.4 76 274 —
5000413600 50501020400400 EN 50306-3 300V 4x1.50 MM S 4x1.5 0.2 6.0 7.0 99 334 —
5000122400 50501020100500 EN 50306-3 300V 1x2.50 MM S 1x2.5 0.2 3.6 4.4 44 148 —
5000214000 50501020200500 EN 50306-3 300V 2x2.50 MM S 2x2.5 0.2 6.4 7.4 89 287 —
5000308400 50501020300500 EN 50306-3 300V 3x2.50 MM S 3x2.5 0.2 6.8 7.8 115 375 —
5000413700 50501020400500 EN 50306-3 300V 4x2.50 MM S 4x2.5 0.2 7.5 8.5 151 566 —
Note: 1. Base cores are according to EN 50306-2 2. Core identification: print numbers 3. Marking: FLAMEX® 448 EN 50306-3 300V《n》x《Section》MM S 90 YY MM DD
Page 11 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
EN 50306-4 Table 1 Class PMulti core, thin wall insulation, standard wall sheath (min 0.42mm), unscreened. Technical data
TYPE NO.
DesignationCross
section Overall Ø Average
Weight Fireload Inventory
Old NewMin. Max.
mm2 mm mm kg/km MJ/km
5000215400 50501030200100 EN 50306-4 1P 2x0.50 MM 2x0.5 3.6 4.6 22 186 —5000309500 50501030300100 EN 50306-4 1P 3x0.50 MM 3x0.5 3.8 4.8 29 219 —5000414800 50501030400100 EN 50306-4 1P 4x0.50 MM 4x0.5 4.1 5.1 37 254 —5000609000 50501030600100 EN 50306-4 1P 6x0.50 MM 6x0.5 4.9 5.9 54 428 —5000703100 50501030700100 EN 50306-4 1P 7x0.50 MM 7x0.5 4.9 5.9 58 358 —5001206000 50501031200100 EN 50306-4 1P 12x0.50 MM 12x0.5 7.0 8.0 98 522 —5001301500 50501031300100 EN 50306-4 1P 13x0.50 MM 13x0.5 7.3 8.3 104 621 —5001901500 50501031900100 EN 50306-4 1P 19x0.50 MM 19x0.5 8.1 9.1 145 799 —5003701500 50501033700100 EN 50306-4 1P 37x0.50 MM 37x0.5 10.8 12.0 272 1363 —
5000215500 50501030200200 EN 50306-4 1P 2x0.75 MM 2x0.75 4.0 5.0 28 192 —5000309600 50501030300200 EN 50306-4 1P 3x0.75 MM 3x0.75 4.2 5.2 35 224 —5000414900 50501030400200 EN 50306-4 1P 4x0.75 MM 4x0.75 4.6 5.6 47 265 —5000503400 50501030500500 EN 50306-4 1P 5x0.75 MM 5x0.75 5.1 6.0 58 317 —5000607200 50501030600200 EN 50306-4 1P 6x0.75 MM 6x0.75 5.4 6.0 67 369 —5000703200 50501030700200 EN 50306-4 1P 7x0.75 MM 7x0.75 5.5 6.5 74 386 —5001002100 50501031000100 EN 50306-4 1P 10x0.75 MM 10x0.75 7.4 8.1 105 594 —5001301600 50501031300200 EN 50306-4 1P 13x0.75 MM 13x0.75 8.2 9.2 134 692 —5001601000 50501031600100 EN 50306-4 1P 16x0.75 MM 16x0.75 8.3 9.3 161 834 —5001901600 50501031900200 EN 50306-4 1P 19x0.75 MM 19x0.75 9.0 10.2 190 985 —5003701600 50501033700200 EN 50306-4 1P 37x0.75 MM 37x0.75 12.2 13.4 353 1543 —5004800400 50501034800100 EN 50306-4 1P 48x0.75 MM 48x0.75 13.9 15.5 459 2222 —
5000215100 50501030200300 EN 50306-4 1P 2x1.00 MM 2x1.0 4.3 5.3 33 197 —5000309700 50501030300300 EN 50306-4 1P 3x1.00 MM 3x1.0 4.6 5.6 45 235 —5000415000 50501030400300 EN 50306-4 1P 4x1.00 MM 4x1.0 4.9 5.9 57 285 —5000703300 50501030700300 EN 50306-4 1P 7x1.00 MM 7x1.0 6.0 7.0 92 440 —5001301700 50501031300300 EN 50306-4 1P 13x1.00 MM 13x1.0 8.7 9.9 172 772 —5001901700 50501031900300 EN 50306-4 1P 19x1.00 MM 19x1.0 9.8 11.0 240 1026 —5003701700 50501033700300 EN 50306-4 1P 37x1.00 MM 37x1.0 13.3 14.5 448 1882 —
Note: 1. Base cores are according to EN 50306-2 2. * meaning include a green-yellow core 3.Core identification: print numbers 4. Marking: FLAMEX® 448 EN 50306-4 1P 300V《n》x《Section》MM 90 YY MM DD
Low
vol
tage
cont
rol c
able
s
Page 12 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. Base cores are according to EN 50306-2 2. * meaning include a green-yellow core 3.Core identification: print numbers 4. Marking: FLAMEX® 448 EN 50306-4 1P 300V《n》x《Section》MM 90 YY MM DD
Page 13 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
EN 50306-4 Table 1 Class EMulti core, thin wall insulation, standard wall sheath (min 1.00mm), unscreened.Technical data
TYPE NO.
DesignationCross
section Overall Ø Average
Weight Fireload Inventory
Old NewMin. Max.
mm2 mm mm kg/km MJ/km5000215600 50501030200600 EN 50306-4 1E 2x0.50 MM 2x0.5 4.9 5.9 36 384 —5000310000 50501030300600 EN 50306-4 1E 3x0.50 MM 3x0.5 5.1 6.1 41 405 —5000415300 50501030400600 EN 50306-4 1E 4x0.50 MM 4x0.5 5.5 6.5 53 454 —5000703600 50501030700600 EN 50306-4 1E 7x0.50 MM 7x0.5 6.3 7.3 72 594 —5000806300 50501030800100 EN 50306-4 1E 8x0.50 MM 8x0.5 6.6 7.4 80 498 —5001302000 50501031300600 EN 50306-4 1E 13x0.50 MM 13x0.5 8.3 9.3 119 925 —5001901900 50501031900500 EN 50306-4 1E 19x0.50 MM 19x0.5 9.0 10.2 162 1127 —5003701900 50501033700500 EN 50306-4 1E 37x0.50 MM 37x0.5 12.3 13.5 297 2000 —
5000215700 50501030200700 EN 50306-4 1E 2x0.75 MM 2x0.75 5.3 6.3 35 416 —5000310100 50501030300700 EN 50306-4 1E 3x0.75 MM 3x0.75 5.5 6.5 49 462 —5000415400 50501030400700 EN 50306-4 1E 4x0.75 MM 4x0.75 6.0 7.0 60 523 —5000703700 50501030700700 EN 50306-4 1E 7x0.75 MM 7x0.75 6.9 7.9 91 681 —5001302100 50501031300700 EN 50306-4 1E 13x0.75 MM 13x0.75 9.1 10.3 151 1029 —5001902000 50501031900600 EN 50306-4 1E 19x0.75 MM 19x0.75 10.0 11.2 212 1278 —5003702000 50501033700600 EN 50306-4 1E 37x0.75 MM 37x0.75 13.2 14.4 380 2047 —5004800500 50501034800200 EN 50306-4 1E 48x0.75 MM 48x0.75 14.8 16.4 483 2788 —
5000215800 50501030200800 EN 50306-4 1E 2x1.00 MM 2x1.0 5.6 6.6 50 432 —5000310200 50501030300800 EN 50306-4 1E 3x1.00 MM 3x1.0 5.9 6.9 61 482 —5000415500 50501030400800 EN 50306-4 1E 4x1.00 MM 4x1.0 6.3 7.3 71 544 —5000703800 50501030700800 EN 50306-4 1E 7x1.00 MM 7x1.0 7.3 8.3 109 796 —5001302200 50501031300800 EN 50306-4 1E 13x1.00 MM 13x1.0 9.7 10.9 187 1138 —5001902100 50501031900700 EN 50306-4 1E 19x1.00 MM 19x1.0 10.7 11.9 262 1406 —5003702100 50501033700700 EN 50306-4 1E 37x1.00 MM 37x1.0 14.0 15.6 282 2309 —
5000215900 50501030200900 EN 50306-4 1E 2x1.50 MM 2x1.5 6.3 7.3 63 547 —5000310300 50501030300900 EN 50306-4 1E 3x1.50 MM 3x1.5 6.6 7.6 82 624 —5000415600 50501030400900 EN 50306-4 1E 4x1.50 MM 4x1.5 7.4 8.4 102 720 —5000703900 50501030700900 EN 50306-4 1E 7x1.50 MM 7x1.5 8.6 9.8 160 971 —5001203300 50501031200300 EN 50306-4 1E 12x1.5 MM 12x1.5 11.1 12.2 258 1524 —5001302300 50501031300900 EN 50306-4 1E 13x1.50 MM 13x1.5 11.7 12.9 278 1584 —5001902200 50501031900800 EN 50306-4 1E 19x1.50 MM 19x1.5 13.0 14.2 387 2003 —5003702200 50501033700800 EN 50306-4 1E 37x1.50 MM 37x1.5 17.2 18.8 715 3376 —
5000216000 50501030201000 EN 50306-4 1E 2x2.5 MM 2x2.5 7.7 8.7 97 692 —5000310400 50501030301000 EN 50306-4 1E 3x2.5 MM 3x2.5 8.1 9.1 130 802 —5000415700 50501030401000 EN 50306-4 1E 4x2.5 MM 4x2.5 8.8 10.0 161 974 —5000704000 50501030701000 EN 50306-4 1E 7x2.5 MM 7x2.5 9.7 10.9 257 1248 —5001302400 50501031301000 EN 50306-4 1E 13x2.5 MM 13x2.5 13.3 14.5 455 1945 —
Note: 1. Base cores are according to EN 50306-2 2. Core identification: print numbers 3. Marking: FLAMEX® 448 EN 50306-4 1E 300V《n》x《Section》MM 90 YY MM DD
Low
vol
tage
cont
rol c
able
s
Page 14 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
EN 50306-4 Table 3 Class PMulti core, thin wall insulation, standard wall sheath (min 0.42mm), overall screened.Technical data
TYPE NO.
DesignationCross
section Overall Ø Average
Weight Fireload Inventory
Old NewMin. Max.
mm2 mm mm kg/km MJ/km5000214100 50501030201100 EN 50306-4 3P 2x0.50 MM S 2x0.5 4.1 5.1 30 327 √5000308500 50501030301100 EN 50306-4 3P 3x0.50 MM S 3x0.5 4.3 5.3 38 374 —5000413800 50501030401100 EN 50306-4 3P 4x0.50 MM S 4x0.5 4.7 5.7 46 436 —5000503100 50501030500100 EN 50306-4 3P 5x0.50 MM S 5x0.5 5.0 6.0 56 497 —5000606400 50501030600300 EN 50306-4 3P 6x0.50 MM S 6x0.5 5.5 6.5 66 559 √5000704100 50501030701100 EN 50306-4 3P 7x0.50 MM S 7x0.5 5.5 6.5 70 616 —5000805500 50501030800200 EN 50306-4 3P 8x0.50 MM S 8x0.5 6.0 7.0 78 673 —5001500300 50501031500100 EN 50306-4 3P 15x0.50 MM S 15x0.5 7.9 9.0 134 790 —5002500500 50501032500100 EN 50306-4 3P 25x0.50 MM S 25x0.5 9.9 10.7 214 2008 —
/ 50501033600100 EN 50306-4 3P 36x0.50 MM S 36x0.5 11.5 13.5 315 2450 —
5000214200 50501030201200 EN 50306-4 3P 2x0.75 MM S 2x0.75 4.5 5.5 42 369 √5000308600 50501030301200 EN 50306-4 3P 3x0.75 MM S 3x0.75 4.7 5.7 50 431 √5000413900 50501030401200 EN 50306-4 3P 4x0.75 MM S 4x0.75 5.2 6.2 57 507 √5000606500 50501030600400 EN 50306-4 3P 6x0.75 MM S 6x0.75 6.1 7.1 82 668 —5000808100 50501030800500 EN 50306-4 3P 8x0.75 MM S 8x0.75 7.5 8.1 115 126 √5001002000 50501031000300 EN 50306-4 3P 10x0.75 MM S 10x0.75 8.0 8.6 126 995 —5001203000 50501031200400 EN 50306-4 3P 12x0.75 MM S 12x0.75 8.4 9.6 144 1184 —
5000214300 50501030201300 EN 50306-4 3P 2x1.00 MM S 2x1.0 4.7 5.7 43 384 √5000308700 50501030301300 EN 50306-4 3P 3x1.00 MM S 3x1.0 5.1 6.0 56 455 —5000414000 50501030401300 EN 50306-4 3P 4x1.00 MM S 4x1.0 5.5 6.5 68 526 —5000503500 50501030500600 EN 50306-4 3P 5x1.00 MM S 5x1.0 6.0 6.9 86 610 —5000606300 50501030600500 EN 50306-4 3P 6x1.00 MM S 6x1.0 6.6 7.6 99 706 —5000702900 50501030701200 EN 50306-4 3P 7x1.00 MM S 7x1.0 6.8 7.8 111 1047 —5000805700 50501030800600 EN 50306-4 3P 8x1.00 MM S 8x1.0 7.7 8.7 128 1146 —5001601200 50501031600300 EN 50306-4 3P 16x1.00 MM S 16x1.0 9.7 10.9 226 1033 —5002500700 50501032500200 EN 50306-4 3P 25x1.00 MM S 25x1.0 12.3 13.6 344 1523 —5003100100 50501033100100 EN 50306-4 3P 31x1.00 MM S 31x1.0 13.2 14.6 415 1721 —
5000214400 50501030201400 EN 50306-4 3P 2x1.50 MM S 2x1.5 5.7 6.7 61 516 √5000308800 50501030301400 EN 50306-4 3P 3x1.50 MM S 3x1.5 6.0 7.0 82 621 —5000414100 50501030401400 EN 50306-4 3P 4x1.50 MM S 4x1.5 6.6 7.6 102 744 —5000502800 50501030500200 EN 50306-4 3P 5x1.50 MM S 5x1.5 7.5 8.1 131 971 —5000606700 50501030600600 EN 50306-4 3P 6x1.50 MM S 6x1.5 8.3 9.3 156 1099 —5000805800 50501030800700 EN 50306-4 3P 8x1.50 MM S 8x1.5 8.9 10.1 188 1331 —5001204000 50501031200500 EN 50306-4 3P 12x1.50 MM S 12x1.5 10.6 11.6 263 1819 —
5000214500 50501030201500 EN 50306-4 3P 2x2.50 MM S 2x2.5 7.3 8.3 102 834 —5000308900 50501030301500 EN 50306-4 3P 3x2.50 MM S 3x2.5 7.7 8.7 131 990 —5000414200 50501030401500 EN 50306-4 3P 4x2.50 MM S 4x2.5 8.4 9.6 165 1175 —5000503200 50501030500300 EN 50306-4 3P 5G1.50 MM S* 5G1.5 7.5 8.1 131 971 —
Note: 1. Base cores are according to EN 50306-2 2. * meaning include a green-yellow core 3. Core identification: print numbers 4. Marking: FLAMEX® 448 EN 50306-4 3P 300V《n》x《Section》MM S 90 YY MM DD
Page 15 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
EN 50306-4 Table 3 Class EMulti core, thin wall insulation, standard wall sheath (min 1.00mm), overall screened.Technical data
TYPE NO.
DesignationCross
section Overall Ø Average
Weight Fireload Inventory
Old NewMin. Max.
mm2 mm mm kg/km MJ/km
5000214600 50501030201600 EN 50306-4 3E 2x0.50 MM S 2x0.5 5.5 6.5 49 729 —5000309000 50501030301600 EN 50306-4 3E 3x0.50 MM S 3x0.5 5.7 6.7 54 801 —5000414300 50501030401600 EN 50306-4 3E 4x0.50 MM S 4x0.5 6.1 7.1 63 891 —5000606800 50501030600700 EN 50306-4 3E 6x0.50 MM S 6x0.5 6.9 7.9 84 1071 —5000805900 50501030800800 EN 50306-4 3E 8x0.50 MM S 8x0.5 7.5 8.5 101 1284 —5002500600 50501032500300 EN 50306-4 3E 25x0.50 MM S 25x0.5 11.0 12.0 238 2672 —
5000214700 50501030201700 EN 50306-4 3E 2x0.75 MM S 2x0.75 5.9 6.9 57 810 —5000309100 50501030301700 EN 50306-4 3E 3x0.75 MM S 3x0.75 6.2 7.2 64 891 —5000414400 50501030401700 EN 50306-4 3E 4x0.75 MM S 4x0.75 6.5 7.5 76 999 —5000606900 50501030600800 EN 50306-4 3E 6x0.75 MM S 6x0.75 7.5 8.5 103 1232 —5000806000 50501030800900 EN 50306-4 3E 8x0.75 MM S 8x0.75 8.2 9.2 125 1478 —5001205000 50501031200600 EN 50306-4 3E 12x0.75 MM S 12x0.7 9.0 10.0 161 1667 —
5000214800 50501030201800 EN 50306-4 3E 2x1.00 MM S 2x1.0 6.2 7.2 60 767 —5000309200 50501030301800 EN 50306-4 3E 3x1.00 MM S 3x1.0 6.5 7.5 74 976 —5000414500 50501030401800 EN 50306-4 3E 4x1.00 MM S 4x1.0 6.9 7.9 89 1108 —5000607000 50501030600900 EN 50306-4 3E 6x1.00 MM S 6x1.0 8.0 9.0 122 1364 —5000703000 50501030701300 EN 50306-4 3E 7x1.00 MM S 7x1.0 8.0 9.0 129 1487 —5000806100 50501030801000 EN 50306-4 3E 8x1.00 MM S 8x1.0 8.6 9.8 146 1634 —
5000214900 50501030201900 EN 50306-4 3E 2x1.50 MM S 2x1.5 7.1 8.1 82 1052 —5000309300 50501030301900 EN 50306-4 3E 3x1.50 MM S 3x1.5 7.4 8.4 97 1175 —5000414600 50501030401900 EN 50306-4 3E 4x1.50 MM S 4x1.5 8.0 9.0 125 1393 —5000607100 50501030601000 EN 50306-4 3E 6x1.50 MM S 6x1.5 9.2 10.4 174 1719 —5000806200 50501030801100 EN 50306-4 3E 8x1.50 MM S 8x1.5 10.2 11.4 207 2084 —
5000215000 50501030202000 EN 50306-4 3E 2x2.50 MM S 2x2.5 8.3 9.3 117 1288 —5000309400 50501030302000 EN 50306-4 3E 3x2.50 MM S 3x2.5 8.6 9.8 147 1483 —5000414700 50501030402000 EN 50306-4 3E 4x2.50 MM S 4x2.5 9.4 10.8 186 1691 —
Note: 1. Base cores are according to EN 50306-2 2. Core identification: print numbers 3. Marking: FLAMEX® 448 EN 50306-4 3E 300V《n》x《Section》MM S 90 YY MM DD
Low
vol
tage
cont
rol c
able
s
Page 16 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
EN 50306-4 Table 5 Class PMulti pairs, thin wall insulation, individually screened and sheathed, standard wall overall sheath (min 0.56mm).Technical data
TYPE NO.
DesignationCross
section Overall Ø Average
Weight Fireload Inventory
Old NewMin. Max.
mm2 mm mm kg/km MJ/km
5000416600 50501030402100 EN 50306-4 5P 2x2x0.50 MMM S 2x2x0.5 9.0 10.2 108 659 —5000608100 50501030601100 EN 50306-4 5P 3x2x0.50 MMM S 3x2x0.5 9.6 10.8 138 832 —5000807200 50501030801200 EN 50306-4 5P 4x2x0.50 MMM S 4x2x0.5 10.7 11.9 157 1021 —5001402900 50501031400100 EN 50306-4 5P 7x2x0.50 MMM S 7x2x0.5 13.0 14.2 256 1568 —
5000416700 50501030402200 EN 50306-4 5P 2x2x0.75 MMM S 2x2x0.75 9.8 11.0 122 739 —5000608200 50501030601200 EN 50306-4 5P 3x2x0.75 MMM S 3x2x0.75 10.5 11.7 158 928 —5000807300 50501030801300 EN 50306-4 5P 4x2x0.75 MMM S 4x2x0.75 11.6 12.8 173 1149 —5001403000 50501031400200 EN 50306-4 5P 7x2x0.75 MMM S 7x2x0.75 14.0 15.6 289 1757 —
5000416800 50501030402300 EN 50306-4 5P 2x2x1.00 MMM S 2x2x1.0 10.2 11.6 144 763 —5000608300 50501030601300 EN 50306-4 5P 3x2x1.00 MMM S 3x2x1.0 10.9 12.1 178 966 —5000807400 50501030801400 EN 50306-4 5P 4x2x1.00 MMM S 4x2x1.0 12.1 13.3 201 1187 —5001403100 50501031400300 EN 50306-4 5P 7x2x1.00 MMM S 7x2x1.0 14.6 16.2 330 1825 —
5000416900 50501030402400 EN 50306-4 5P 2x2x1.50 MMM S 2x2x1.5 12.2 13.4 209 958 —5000608400 50501030601400 EN 50306-4 5P 3x2x1.50 MMM S 3x2x1.5 13.1 14.3 273 1226 —5000807500 50501030801500 EN 50306-4 5P 4x2x1.50 MMM S 4x2x1.5 14.3 15.8 315 1518 —5001403200 50501031400400 EN 50306-4 5P 7x2x1.50 MMM S 7x2x1.5 17.6 19.2 531 2345 —
Note: 1. Base cores are according to EN 50306-2 2. Individual pairs are according to EN 50306-3 3. Core identification: print numbers 4. Marking: FLAMEX® 448 EN 50306-4 5P 300V《n》x《Section》MMM S 90 YY MM DD
Page 17 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
EN 50306-4 Table 5 Class EMulti pairs, thin wall insulation, individually screened and sheathed, standard wall overall sheath (min 1.00mm).Technical data
TYPE NO.
DesignationCross
section Overall Ø Average
Weight Fireload Inventory
Old NewMin. Max.
mm2 mm mm kg/km MJ/km
5000417000 50501030402500 EN 50306-4 5E 2x2x0.50 MMM S 2x2x0.5 10.1 11.3 132 1078 —5000608500 50501030601500 EN 50306-4 5E 3x2x0.50 MMM S 3x2x0.5 10.8 12.0 163 1286 —5000807600 50501030801600 EN 50306-4 5E 4x2x0.50 MMM S 4x2x0.5 11.8 13.0 185 1521 —5001403300 50501031400500 EN 50306-4 5E 7x2x0.50 MMM S 7x2x0.5 13.9 15.5 289 1943 —
5000417100 50501030402600 EN 50306-4 5E 2x2x0.75 MMM S 2x2x0.75 10.9 12.1 147 1182 —5000608600 50501030601600 EN 50306-4 5E 3x2x0.75 MMM S 3x2x0.75 11.6 12.8 180 1404 —5000807700 50501030801700 EN 50306-4 5E 4x2x0.75 MMM S 4x2x0.75 12.8 14.0 203 1680 —5001403400 50501031400600 EN 50306-4 5E 7x2x0.75 MMM S 7x2x0.75 16.1 16.7 330 2386 —
5000417200 50501030402700 EN 50306-4 5E 2x2x1.00 MMM S 2x2x1.0 11.3 12.5 166 1231 —5000608700 50501030601700 EN 50306-4 5E 3x2x1.00 MMM S 3x2x1.0 12.0 13.2 207 1502 —5000807800 50501030801800 EN 50306-4 5E 4x2x1.00 MMM S 4x2x1.0 13.2 14.4 233 1748 —5001403500 50501031400700 EN 50306-4 5E 7x2x1.00 MMM S 7x2x1.0 15.7 17.3 369 2509 —
5000417300 50501030402800 EN 50306-4 5E 2x2x1.50 MMM S 2x2x1.5 13.3 14.5 242 1560 —5000608800 50501030601800 EN 50306-4 5E 3x2x1.50 MMM S 3x2x1.5 14.0 15.6 307 1882 —5000807900 50501030801900 EN 50306-4 5E 4x2x1.50 MMM S 4x2x1.5 15.5 17.1 353 2265 —5001403600 50501031400800 EN 50306-4 5E 7x2x1.50 MMM S 7x2x1.5 18.7 20.3 572 2928 —
Note: 1. Base cores are according to EN 50306-2 2. Individual pairs are according to EN 50306-3 3. Core identification: print numbers 4. Marking: FLAMEX® 448 EN 50306-4 5E 300V《n》x《Section》MMM S 90 YY MM DD
Low
vol
tage
cont
rol c
able
s
Page 18 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
EN 50306-4 Class PMulti pairs, thin wall insulation, overall screened and standard wall sheath (min 0.42mm).Technical data
TYPE NO.
DesignationCross
section Overall Ø Average
Weight Fireload Inventory
Old NewMin. Max.
mm2 mm mm kg/km MJ/km
5000415800 50501030402900 EN 50306-4 P 300V 2x2x0.50 MM S 2x2x0.5 6.2 7.4 59 317 —5000607300 50501030601900 EN 50306-4 P 300V 3x2x0.50 MM S 3x2x0.5 6.5 7.7 72 372 —5000806400 50501030802000 EN 50306-4 P 300V 4x2x0.50 MM S 4x2x0.5 7.4 8.6 89 501 —5001002300 50501031000400 EN 50306-4 P 300V 5x2x0.50 MM S 5x2x0.5 8.4 9.0 114 561 —5001203400 50501031200700 EN 50306-4 P 300V 6x2x0.50 MM S 6x2x0.5 8.5 9.5 129 629 —5001402100 50501031400900 EN 50306-4 P 300V 7x2x0.50 MM S 7x2x0.5 8.8 10.0 135 703 —
5000415900 50501030403000 EN 50306-4 P 300V 2x2x0.75 MM S 2x2x0.75 7.0 8.2 72 405 —5000607400 50501030602000 EN 50306-4 P 300V 3x2x0.75 MM S 3x2x0.75 7.3 8.5 93 482 —5000806500 50501030802100 EN 50306-4 P 300V 4x2x0.75 MM S 4x2x0.75 8.2 9.4 114 566 —5001002400 50501031000500 EN 50306-4 P 300V 5x2x0.75 MM S 5x2x0.75 8.7 9.9 131 654 —5001203500 50501031200800 EN 50306-4 P 300V 6x2x0.75 MM S 6x2x0.75 9.6 10.2 160 750 —5001402200 50501031401000 EN 50306-4 P 300V 7x2x0.75 MM S 7x2x0.75 9.9 11.1 175 889 —
5000416000 50501030403100 EN 50306-4 P 300V 2x2x1.00 MM S 2x2x1.0 7.6 8.8 76 421 —5000607500 50501030602100 EN 50306-4 P 300V 3x2x1.00 MM S 3x2x1.0 7.9 9.1 107 509 —5000806600 50501030802200 EN 50306-4 P 300V 4x2x1.00 MM S 4x2x1.0 8.8 10.0 140 599 —5001203600 50501031200900 EN 50306-4 P 300V 6x2x1.00 MM S 6x2x1.0 10.6 11.6 206 834 —5001402300 50501031401100 EN 50306-4 P 300V 7x2x1.00 MM S 7x2x1.0 10.8 12.0 211 865 —
5000416100 50501030403200 EN 50306-4 P 300V 2x2x1.50 MM S 2x2x1.5 8.7 9.9 119 577 —5000607600 50501030602200 EN 50306-4 P 300V 3x2x1.50 MM S 3x2x1.5 9.2 10.4 153 700 —5000806700 50501030802300 EN 50306-4 P 300V 4x2x1.50 MM S 4x2x1.5 10.4 11.6 194 848 —5001402400 50501031401200 EN 50306-4 P 300V 7x2x1.50 MM S 7x2x1.5 13.1 14.3 310 1270 —
Note: 1. Base cores are according to EN 50306-2 2. Core identification: print numbers 3. Marking: FLAMEX® 448 EN 50306-4 P 300V《n》x《Section》MM S 90 YY MM DD
Page 19 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
EN 50306-4 Class EMulti pairs, thin wall insulation, overall screened and standard wall sheath (min 1.00mm).Technical data
TYPE NO.
DesignationCross
section Overall Ø Average
Weight Fireload Inventory
Old NewMin. Max.
mm2 mm mm kg/km MJ/km
5000416200 50501030403300 EN 50306-4 E 300V 2x2x0.50 MM S 2x2x0.5 7.2 8.4 77 610 —5000607700 50501030602300 EN 50306-4 E 300V 3x2x0.50 MM S 3x2x0.5 7.5 8.7 90 679 —5000806800 50501030802400 EN 50306-4 E 300V 4x2x0.50 MM S 4x2x0.5 8.4 9.6 110 834 —5001402500 50501031401300 EN 50306-4 E 300V 7x2x0.50 MM S 7x2x0.5 9.8 11.0 157 1094 —
5000416300 50501030403400 EN 50306-4 E 300V 2x2x0.75 MM S 2x2x0.75 8.0 9.2 92 698 —5000607800 50501030602400 EN 50306-4 E 300V 3x2x0.75 MM S 3x2x0.75 8.4 9.6 109 782 —5000806900 50501030802500 EN 50306-4 E 300V 4x2x0.75 MM S 4x2x0.75 9.2 10.4 132 900 —5001402600 50501031401400 EN 50306-4 E 300V 7x2x0.75 MM S 7x2x0.75 10.8 12.0 195 1253 —
5000416400 50501030403500 EN 50306-4 E 300V 2x2x1.00 MM S 2x2x1.0 8.6 9.8 106 785 —5000607900 50501030602500 EN 50306-4 E 300V 3x2x1.00 MM S 3x2x1.0 8.9 10.1 128 878 —5000807000 50501030802600 EN 50306-4 E 300V 4x2x1.00 MM S 4x2x1.0 9.8 11.0 156 1010 —5001402700 50501031401500 EN 50306-4 E 300V 7x2x1.00 MM S 7x2x1.0 11.6 12.8 235 1346 —
5000416500 50501030403600 EN 50306-4 E 300V 2x2x1.50 MM S 2x2x1.5 9.7 10.9 137 996 —5000608000 50501030602600 EN 50306-4 E 300V 3x2x1.50 MM S 3x2x1.5 10.1 11.3 175 1089 —5000807100 50501030802700 EN 50306-4 E 300V 4x2x1.50 MM S 4x2x1.5 11.2 12.4 217 1297 —5001402800 50501031401600 EN 50306-4 E 300V 7x2x1.50 MM S 7x2x1.5 13.5 14.7 335 1806 —
Note: 1. Base cores are according to EN 50306-2 2. Core identification: print numbers 3. Marking: FLAMEX® 448 EN 50306-4 E 300V《n》x《Section》MMM S 90 YY MM DD
Low
vol
tage
cont
rol c
able
s
Page 20 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nominal voltage 300/500 VTesting a.c. voltage (5 minutes)
for insulation: U0 = 2.0 kV for EN 50306-3 sheath: U0 = 2.0 kVfor EN 50306-4 internal sheath: U0 = 2.0 kV
Max. operating temperature at conductor
Conductor at normal operationEN 50306-2 wires: ≤ 105°C / 100,000 h ≤ 125°C / 20,000 h
EN 50306-3 and EN 50306-4 cables: ≤ 90°C / 100,000 h ≤ 110°C / 20,000 h
Conductor under short-circuit conditions(tinned) ≤ 160°C / 5 s
Operating in cold
Min. permissible ambient temperature ≥ -40℃
Min. bending radii
Unscreened cables:Fixed installation ≥ 2DFree moved ≥ 4D
Screened cables:Fixed installation ≥ 3DFree moved ≥ 5D
D = cable Ø (mm)
Page 21 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
According to EN 50306(See notes under technical data for details)
Standards
EN 45545-2 / BS 6853 / UNI CEI 11170-3
Thin wall insulated cablesFLAMEX® SH20600V
ApplicationsStrictly halogen free, all these wires and cables combine the advantages of thin wall thickness, small size, lightweight, high mechanical properties, and high chemical resistance. They are recommended for installation in railway vehicles, switching stations and control panels.
2. Insulation Special halogen free, thin wall Compound type SH20 Color: White
AmbientTemperature-40°C to 100°C
GoodResistanceto UV & humidity
Goodchemicalresistance
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
EN 50306
Page 23 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. Other colors on request 2. Marking: FLAMEX® SH20 600V 1x《Section》 M Nexans 448 week/year
Low
vol
tage
cont
rol c
able
s
Page 24 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Part 2-1 EN 50264-3 reduced thickness power cables
Nexans EN 50264-3 TypesSinglecore
cables
Multcore
cables
With agreen/yellow
corescreened sheathed Page
EN 50264-3-1 0.6/1kVCategory M ● ● 29
EN 50264-3-1 1.8/3kVCategory M ● ● 30
EN 50264-3-1 1.8/3kVCategory MM ● ● 30
EN 50264-3-1 3.6/6kVCategory MM ● ● 31
EN 50264-3-2 0.6/1kVCategory MM ● ● 35
EN 50264-3-2 S 0.6/1kVCategory MM ● ● ● 36
EN 50264-3-2 0.6/1kVCategory FM ● ● ● 37
EN 50264-3-2 S 0.6/1kVCategory FM ● ● ● ● 38
Part 2-2 High temperature power cables
Nexans EN 50382-2 TypesSinglecore
cables
Multcore
cables
With agreen/yellow
corescreened sheathed Page
EN 50382-2 0.6/1kV 120°CCategory F ● 43
EN 50382-2 1.8/3kV 120°CCategory F ● 44
EN 50382-2 1.8/3kV 120°CCategory FF ● ● 44
EN 50382-2 3.6/6kV 120°CCategory F ● 45
EN 50382-2 3.6/6kV 120°CCategory FF ● ● 45
Guidelines
Page 27 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Part 2-4 High performance thin wall thickness power cables
Nexans EN 50264-3 TypesSinglecore
cables
Multcore
cables
With agreen/yellow
corescreened sheathed Page
4GKW-EN 1800V ● 55
(N)SHXAFOE 3600V ● 56
(N)SHXAFCOE 1800V ● ● ● 59
SHXAFCOE 3600V ● ● ● 59
Pow
er c
able
s
Page 28 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
FLAMEX Z – EN 50264-3-1 – Voltage Rate –《section》– Hazard Level –NEXANS – 448 – Week/Year
Standards
EN 45545-2 / BS 6853 / NFPA130 / UNI CEI 11170-3
Single core cablesFLAMEX® Z types0.6/1kV, 1.8/3kV, 3.6/6kV
ApplicationsStrictly halogen free, all these wires combine the advantages of reduced size, lightweight, high chemical resistance and high mechanical properties. They are recommended for installation in railway vehicles for power supply.
Current carrying capacity according to EN 50343.
Cabling rules according to EN 50355.
Construction1. Conductor
Flexible stranded tinned copperClass 5 acc. to IEC 60228Covered with separate tape (Optional)
2. InsulationSpecial cross-linked compoundType EI 109 or EI 107 acc. to EN 50264-1Color: Black or Green-Yellow
3. SheathSpecial cross-linked compoundType EM 104 acc. to EN 50264-1Inside covered with optional tapesColor: Black
AmbientTemperature-40°C to 85°C
GoodResistanceto UV & humidity
Goodchemicalresistance
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
EN 50264-3-1
FLA
MEX
Z u
nshe
athe
d
FLA
MEX
Z s
heat
hed
1
2
3
Page 31 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: G* means it's a green/yellow wire, it only can be used for earthing.
Pow
er c
able
s
Page 32 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
New mm mm mm mm kg/km MJ/km51420019 50524040040000 1.5 1.5 2.0 5.3 5.9 48 610 BK —51420020 50524040050000 2.5 1.9 2.0 5.7 6.3 61 680 BK —51420021 50524040060000 4 2.5 2.0 6.3 7.1 80 805 BK —51420022 50524040070000 6 3.0 2.0 6.8 7.6 101 895 BK —51420023 50524040080000 10 3.9 2.0 7.7 8.5 146 1067 BK —51420024 50524040090000 16 5.3 2.0 9.2 10.0 211 1357 BK —51420025 50524040100000 25 6.5 2.0 10.3 11.3 296 1578 BK √51420026 50524040110000 35 7.7 2.0 11.5 12.5 392 1800 BK √51420027 50524040120000 50 9.2 2.0 12.9 13.9 535 2018 BK √51420028 50524040130000 70 11.1 2.0 14.8 15.8 725 2360 BK √51420029 50524040140000 95 12.9 2.2 16.9 18.1 951 2979 BK √51420030 50524040150000 120 14.4 2.2 18.4 19.6 1166 3275 BK √51420031 50524040160000 150 16.0 2.2 19.9 21.3 1437 3590 BK √51420032 50524040170000 185 18.2 2.4 22.5 23.9 1758 4413 BK √51420033 50524040180000 240 20.5 2.4 24.9 26.3 2239 4906 BK —51420034 50524040190000 300 22.8 2.4 27.1 28.5 2740 5399 BK —51420035 50524040200000 400 26.3 2.6 30.9 32.5 3594 6684 BK —
FLAMEX Z 1.8/3 kV sheathedTechnical data
TYPE NO. Cross section
ThicknessOf
insulation
ThicknessOf
sheath
Overall Ø Average Weight
Fireload
approx. Color InventoryOld New
Min. Max.
mm2 mm mm mm mm kg/km MJ/km51420102 50524050040020 1.5 1.3 0.8 5.7 6.1 52 648 BK —51420103 50524050050020 2.5 1.3 0.8 6.0 6.5 64 720 BK —51420104 50524050060020 4 1.3 0.8 6.5 7.2 84 848 BK —51420105 50524050070020 6 1.3 0.8 7.1 7.7 105 941 BK —51420106 50524050080020 10 1.5 0.8 8.3 9.1 159 1249 BK —51420107 50524050090020 16 1.5 0.8 9.7 10.7 227 1582 BK —51420108 50524050100020 25 1.8 1.0 11.9 12.9 342 2307 BK —51420109 50524050110020 35 1.8 1.0 13.1 14.1 444 2617 BK —51420110 50524050120020 50 1.8 1.0 14.5 15.5 592 2926 BK —51420111 50524050130020 70 1.8 1.0 16.4 17.4 791 3389 BK —51420112 50524050140020 95 2.2 1.0 18.9 20.1 1045 4471 BK —51420113 50524050150020 120 2.2 1.0 20.3 21.7 1268 4888 BK —51420114 50524050160020 150 2.2 1.2 22.4 23.8 1570 5701 BK —51420115 50524050170020 185 2.4 1.2 24.9 26.3 1906 6776 BK —51420116 50524050180020 240 2.4 1.2 27.3 28.7 2401 7492 BK —51420117 50524050190020 300 2.4 1.2 29.5 30.9 2916 8207 BK —51420118 50524050200020 400 2.6 1.4 33.7 35.3 3828 10424 BK —
Page 33 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Conductor at normal operation ≤ 90°C / 100,000 h ≤ 120°C / 20,000 h
Conductor under short-circuit conditions(tinned) ≤ 200 °C / 5 s
Operating in cold
Min. permissible ambient temperature ≥ -40°C
Min. bending radii
D < 12 D ≥ 12Fixed installation ≥ 3D ≥ 4DFree moved ≥ 4D ≥ 5DD = cable Ø (mm)
Page 35 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
FLAMEX Z – EN 50264-3-2 – 600V –《number》x《section》 – Hazard Level – (G, if with a green/yellow core) – (S, if screened) –NEXANS – 448 – Week/Year
Standards
EN 45545-2 / BS 6853 / NFPA130 / UNI CEI 11170-3
Multi core cablesFLAMEX® Z types0.6/1kV
ApplicationsStrictly halogen free, all these cables combine the advantages of small size, lightweight, high chemical resistance and high mechanical properties. They are recommended for installation in railway vehicles, inside or outside of switching stations and control panels.
Current carrying capacity according to EN50343.
Cabling rules according to EN 50355.
Construction1. Conductor
Flexible stranded tinned copper Class 5 acc. to IEC 60228Covered with separate tape (Optional)
2. InsulationSpecial cross-linked compound Type EI 109 or EI 107 acc. to EN50264-1Color: Black or Green-Yellow
3. ScreenTinned copper wires braid
4. SheathSpecial cross-linked rubberType EM104 acc. toEN 50264-1Color: Black
AmbientTemperature-40°C to 85°C
GoodResistanceto UV & humidity
Goodchemicalresistance
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
EN 50264-3-2
Page 37 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
mm2 mm mm mm mm kg/km MJ/km56450100 50525010230020 2x1.0 1.3 0.7 6.3 7.3 71 887 BK —51450102 50525010240020 2x1.5 1.5 0.7 7.2 8.3 91 1090 BK —51450103 50525010250020 2x2.5 1.9 0.7 8.0 9.1 120 1302 BK —51450104 50525010260020 2x4 2.5 0.7 9.2 10.4 168 1686 BK —51450105 50525010270020 2x6 3.0 0.8 10.3 11.7 228 2125 BK —51450106 50525010280020 2x10 3.9 1.0 12.5 13.9 347 2938 BK —56450107 50525010290020 2x16 5.3 1.0 15.6 17.0 521 4198 BK —56450108 50525010300020 2x25 6.5 1.2 19.2 20.6 793 6267 BK —56450109 50525010310020 2x35 7.7 1.2 21.4 23.2 1045 7633 BK —56450110 50525010320020 2x50 9.2 1.4 25.1 26.9 1464 10186 BK —51450101 50525010440020 3x1.5 1.5 0.7 7.7 8.8 109 1190 BK —51450111 50525010450020 3x2.5 1.9 0.7 8.5 9.6 146 1402 BK —51450112 50525010460020 3x4 2.5 0.7 9.7 11.1 210 1849 BK —51450113 50525010470020 3x6 3.0 0.8 11.0 12.4 284 2261 BK —51450114 50525010480020 3x10 3.9 1.0 13.4 14.8 442 3108 BK —56450115 50525010490020 3x16 5.3 1.0 16.7 18.1 665 4369 BK —56450116 50525010500020 3x25 6.5 1.2 20.3 22.1 1013 6513 BK —56450117 50525010510020 3x35 7.7 1.4 23.3 25.1 1370 8225 BK —56450118 50525010520020 3x50 9.2 1.6 27.3 29.1 1922 10820 BK —51450119 50525010640020 4x1.5 1.5 0.7 8.5 9.5 132 1375 BK —51450120 50525010650020 4x2.5 1.9 0.7 9.4 10.5 180 1624 BK —51450121 50525010660020 4x4 2.5 0.8 11.0 12.4 274 2372 BK —51450122 50525010670020 4x6 3.0 1.0 12.6 14 375 2952 BK —51450123 50525010680020 4x10 3.9 1.0 14.9 16.3 567 3768 BK —56450124 50525010690020 4x16 5.3 1.2 18.9 20.3 867 5508 BK —56450125 50525010700020 4x25 6.5 1.4 22.9 24.7 1314 8083 BK —56450126 50525010710020 4x35 7.7 1.4 25.8 27.6 1739 9617 BK —56450127 50525010720020 4x50 9.2 1.6 30.2 32.0 2451 12674 BK —56450128 50525011810020 6x1.5 1.5 0.8 10.2 11.6 201 2091 BK —56450129 50525012140020 6x2.5 1.9 1.0 11.8 13.2 285 2666 BK —
Note: 1. Other cross section on request 2. Core identification: print numbers
Pow
er c
able
s
Page 38 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. Other cross section on request 2. Core identification: print numbers
Page 39 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. G* means a green/yellow core included, as photo beside 2.Other cross section on request 3.Core identification: print numbers
Pow
er c
able
s
Page 40 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. G* means a green/yellow core included, as photo beside 2.Other cross section on request 3.Core identification: print numbers
Page 41 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nominal voltage U0/U (Um) = 0.6/1.0 (1.2) kVMax. operating voltage in DC installations, V0 = 0.9 kVone-sided earthed
Testing a.c. voltage (5 minutes)for insulation: U0 = 3.5 kV for sheath (Screened): U0 = 3.0 kV
Max. operating temperature at conductor
Conductor at normal operation ≤ 90°C / 100,000 h ≤ 120°C / 20,000 h
Conductor under short-circuit conditions(tinned) ≤ 200°C / 5 s
Operating in cold
Min. permissible ambient temperature ≥ -40°C
Min. bending radii
Unscreened cables:Fixed installation ≥ 4DFree moved ≥ 5D
Screened cables:Fixed installation ≥ 5DFree moved ≥ 10D
D = cable Ø (mm)
Page 42 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
FLAMEX SI – EN 50382-2 – Voltage Rate –《Section》– Hazard Level – 120°C – NEXANS – 448 – Week/Year
Standards
EN 45545-2 / BS 6853 / NFPA130 / UNI CEI 11170-3
Single core cablesFLAMEX® SI 120℃ types1.8/3kV, 3.6/6kV
ApplicationsThese wires combine the advantages of strictly halogen free, fire retardant, low smoke fume, with a high performance insulation system. They are recommended for high temperature applications in railway vehicles.
Current carrying capacity acc. to EN 50343.
Cabling rules acc. to EN 50355.
Construction1. Conductor
Flexible stranded tinned copperClass 5 acc. to IEC 60228Covered with separate tape (Optional)
2. InsulationSpecial cross-linked halogen free silicone rubberColor: Black or White (only for sheathed)
3. SheathSpecial cross-linked, halogen freesilicone rubberInside covered with optional tapesColor: Black
AmbientTemperature-50°C to 115°C
GoodResistanceto UV & humidity
GoodResistance to impacts
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
EN 50382
Page 45 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
mm2 mm mm mm mm kg/km MJ/km51210001 50521010040000 1.5 1.5 2.5 6.3 7.1 54 642 BK —51210002 50521010050000 2.5 1.9 2.5 6.7 7.5 66 706 BK —51210003 50521010060000 4 2.5 2.5 7.2 8.2 86 827 BK —51210004 50521010070000 6 3.0 2.5 7.7 8.7 108 908 BK —51210005 50521010080000 10 3.9 2.5 8.6 9.6 153 1061 BK —51210006 50521010090000 16 5.3 2.5 9.9 11.1 215 1288 BK —51210007 50521010100000 25 6.5 2.5 11.1 12.3 300 1484 BK —51210008 50521010110000 35 7.7 2.5 12.3 13.5 396 1680 BK —51210009 50521010120000 50 9.2 2.5 13.7 14.9 537 1847 BK —51210010 50521010130000 70 11.1 2.5 15.6 16.8 728 2148 BK —51210011 50521010140000 95 12.9 2.7 17.9 19.1 952 2659 BK —51210012 50521010150000 120 14.4 2.7 19.4 20.6 1166 2915 BK —51210013 50521010160000 150 16.0 2.7 20.8 22.4 1437 3189 BK —51210014 50521010170000 185 18.2 2.7 23.0 24.6 1734 3565 BK —51210015 50521010180000 240 20.5 2.7 25.3 26.9 2213 3958 BK —51210016 50521010190000 300 22.8 2.7 27.6 29.2 2711 4352 BK —51210017 50521010200000 400 26.3 2.9 31.4 33.2 3556 5347 BK —
FLAMEX SI 1.8/3 kV 120°C sheathedTechnical data
TYPE NO. Cross section
ThicknessOf
insulation
ThicknessOf
sheath
Overall Ø Average Weight
Fireload
approx. Color InventoryOld New
Min. Max.
mm2 mm mm mm mm kg/km MJ/km51210101 50521020041020 1.5 1.3 1.4 6.8 7.8 61 763 BK —51210102 50521020051020 2.5 1.3 1.4 7.2 8.2 74 832 BK —51210103 50521020061020 4 1.3 1.4 7.7 8.9 95 968 BK —51210104 50521020071020 6 1.3 1.4 8.2 9.4 117 1057 BK —51210105 50521020081020 10 1.5 1.4 9.5 10.7 171 1349 BK —51210106 50521020091020 16 1.5 1.4 10.9 12.2 239 1665 BK —51210107 50521020101020 25 1.8 1.4 12.7 14.1 342 2146 BK —51210108 50521020111020 35 1.8 1.4 14.0 15.4 442 2405 BK —51210109 50521020121020 50 1.8 1.4 15.4 16.8 588 2641 BK —51210110 50521020131020 70 1.8 1.5 17.2 18.2 791 3143 BK —51210111 50521020141020 95 2.2 1.5 20.0 21.8 1041 4047 BK —51210112 50521020151020 120 2.2 1.6 21.7 23.5 1271 4549 BK —51210113 50521020161020 150 2.2 1.6 23.3 25.1 1550 4946 BK —51210114 50521020171020 185 2.4 1.7 26.1 27.9 1890 5986 BK —51210115 50521020181020 240 2.4 1.8 28.6 30.4 2394 6781 BK —51210116 50521020191020 300 2.4 1.9 30.9 33.5 2920 7607 BK —51210117 50521020201020 400 2.6 2.0 35.0 37.6 3808 9287 BK —
Pow
er c
able
s
Page 46 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Conductor at normal operation ≤ 120°C / 100,000 h ≤ 150°C / 20,000 h
Conductor under short-circuit conditions(tinned) ≤ 250°C / 5 s
Operating in cold
Min. permissible ambient temperature ≥ -50°C
Min. bending radii
D < 12 D ≥ 12Fixed installation ≥ 3D ≥ 4DFree moved ≥ 4D ≥ 5DD = cable Ø (mm)
Pow
er c
able
s
Page 48 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
FLAMEX SI – EN 50382-2 – Voltage Rate – 《section》 – Hazard Level – 150°C –NEXANS – 448 – Week/Year
Standards
EN 45545-2 / BS 6853 / NFPA130 / UNI CEI 11170-3
Single core cablesFLAMEX® SI 150℃ types0.6/1kV, 1.8/3kV, 3.6/6kV
ApplicationsThese wires combine the advantages of strictly halogen free, fire retardant, low smoke fume with a high performance insulation system. They are recommended for extra high temperature applications in railway vehicles to transfer the power.
Current carrying capacity acc. to EN 50343.
Cabling rules acc. to EN 50355.
Construction1. Conductor
Flexible stranded plain copperClass 5 acc. to IEC 60228Covered with separate tape (Optional)
2. InsulationSpecial cross-linked halogen free silicone rubberColor: Black or White (only for sheathed)
3. SheathSpecial cross-linked, halogen free silicone rubberInside covered with optional tapesColor: Black
AmbientTemperature-50°C to 145°C
GoodResistanceto UV & humidity
GoodResistance to impacts
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
EN 50382
Page 51 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. The insulation thickness is according to EN 50264-2-1: 2008 2. The insulation material and cable performance fulfill the requirements in EN 50382:2008 3: Tinned copper conductor
Page 52 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
mm2 mm mm mm mm kg/km MJ/km51222001 50521030040000 1.5 1.5 2.5 6.3 7.1 54 642 BK —51222002 50521030050000 2.5 1.9 2.5 6.7 7.5 67 706 BK —51222003 50521030060000 4 2.5 2.5 7.2 8.2 87 827 BK —51222004 50521030070000 6 3.0 2.5 7.7 8.7 110 908 BK —51222005 50521030080000 10 4.1 2.5 8.8 9.8 158 1092 BK —51222006 50521030090000 16 5.3 2.5 9.9 11.1 219 1288 BK —51222007 50521030100000 25 6.5 2.5 11.1 12.3 302 1484 BK —51222008 50521030110000 35 7.7 2.5 12.3 13.5 402 1680 BK —51222009 50521030120000 50 9.2 2.5 13.8 15.0 545 1847 BK —51222010 50521030130000 70 11.1 2.5 15.6 16.8 736 2148 BK —51222011 50521030140000 95 12.9 2.7 17.9 19.1 960 2659 BK —51222012 50521030150000 120 14.4 2.7 19.3 20.7 1184 2915 BK —51222013 50521030160000 150 16.0 2.7 20.8 22.4 1459 3189 BK —51222014 50521030170000 185 18.2 2.7 23.0 24.6 1765 3565 BK —51222015 50521030180000 240 20.5 2.7 25.3 26.9 2251 3958 BK —51222016 50521030190000 300 22.8 2.7 27.6 29.2 2784 4352 BK —51222017 50521030200000 400 26.3 2.9 31.4 33.2 3688 5347 BK —
FLAMEX SI 1.8/3 kV 150°C sheathedTechnical data
TYPE NO. Cross section
ThicknessOf
insulation
ThicknessOf
sheath
Overall Ø Average Weight
Fireload
approx. Color InventoryOld New
Min. Max.
mm2 mm mm mm mm kg/km MJ/km51222101 50521040041020 1.5 1.3 1.4 6.8 7.8 62 763 BK —51222102 50521040051020 2.5 1.3 1.4 7.2 8.2 75 832 BK —51222103 50521040061020 4 1.3 1.4 7.7 8.9 96 968 BK —51222104 50521040071020 6 1.3 1.4 8.2 9.4 119 1064 BK —51222105 50521040081020 10 1.5 1.4 9.7 11.0 177 1387 BK —51222106 50521040091020 16 1.5 1.4 10.9 12.2 243 1665 BK —51222107 50521040101020 25 1.8 1.4 12.7 14.1 345 2146 BK —51222108 50521040111020 35 1.8 1.4 14.0 15.4 448 2405 BK —51222109 50521040121020 50 1.8 1.4 15.8 17.2 595 2641 BK —51222110 50521040131020 70 1.8 1.5 17.5 18.9 800 3153 BK —51222111 50521040141020 95 2.2 1.5 20.0 21.4 1049 4047 BK —51222112 50521040151020 120 2.2 1.6 21.7 23.5 1289 4549 BK —51222113 50521040161020 150 2.2 1.6 23.0 24.0 1571 4936 BK —51222114 50521040171020 185 2.4 1.7 26.1 27.9 1921 5986 BK —51222115 50521040181020 240 2.4 1.8 28.6 30.4 2432 6781 BK —51222116 50521040191020 300 2.4 1.9 31.1 32.9 2993 7607 BK —51222117 50521040201020 400 2.6 2.0 35.2 37.0 3940 9287 BK —
Page 53 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nominal voltage 1800V Cables: U0 / U (Um) = 1.8/3.0 (3.6) kV 3600V Cables: U0 / U (Um) = 3.6/6.0 (7.2) kV
Max. operating voltage in DC installations, 1800V Cables: V0 = 2.7 kV DCone-sided earthed 3600V Cables: V0 = 5.4 kV DC
Testing a.c. voltage (5 minutes) 1800V Cables: U0 = 6.5 kV 3600V Cables: U0 = 11.0 kV
Max. operating temperature at conductor
Conductor at normal operation ≤ 150 ℃ / 100,000 h ≤ 170 ℃ / 20,000 h
Conductor under short-circuit conditions(tinned) ≤ 350 ℃ / 5 s
Operating in cold
Min. permissible ambient temperature ≥ -50°C
Min. bending radii
D < 12 D ≥ 12Fixed installation ≥ 3D ≥ 4DFree moved ≥ 4D ≥ 5DD = cable Ø (mm)
Page 55 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Single core cablesThin wall thickness types1.8/3kV, 3.6/6kV
ApplicationsStrictly halogen free, all these wires combine the advantages of reduced size, lightweight, high chemical resistance, high mechanical properties. They are recommended for installation indoor or outdoor of railway vehicles for power supply.
Current carrying capacity according to EN 50343.
Cabling rules according to EN 50355.
Construction1. Conductor
Flexible stranded tinned copperClass 5 acc. to IEC 60228Covered with separate tape (Optional)
2. InsulationSpecial cross-linked compoundType EI 110 acc. to EN 50264-1
3. SheathSpecial cross-linked compoundType EM 104, acc. toEN 50264-1Inside covered with optional tapesColor: Black
AmbientTemperature-40°C to 85°C
GoodResistanceto UV & humidity
GoodResistance to impacts
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
4GKW-EN and (N)SHXAFOE
Page 57 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. Marking <25mm2 : KF2U 120 HXAFOE 1800V 《Section》 M NEXANS 448 – week/year ≥ 25mm2 : 4GKW-EN 1.8/3kV EN 50264-3-1 1800V 《Section》 M NEXANS 448 – week/year 2. Other cross section on request
Pow
er c
able
s
Page 58 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. Marking: (N)SHXAFOE 3600V《Section》OM NEXANS 448 week/year 2. Other cross section on request
Page 59 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Max. operating voltage in DC installations, 4GKW-EN: V0 = 2.7 kV DCone-sided earthed (N)SHXAFOE: V0 = 5.4 kV DC
Testing a.c. voltage (5 minutes) 4GKW-EN: U0 = 6.5 kV (N)SHXAFOE: U0 = 11.0 kV
Max. operating temperature at conductor
Conductor at normal operation ≤ 90°C / 250,000 h ≤ 120°C / 20,000 h
Conductor under short-circuit conditions(tinned) ≤ 250°C / 5 s
Operating in cold
Min. permissible ambient temperature ≥ -40°C
Min. bending radii
D < 12 D ≥ 12Fixed installation ≥ 3D ≥ 4DFree moved ≥ 4D ≥ 5DD = cable Ø (mm)
Pow
er c
able
s
Page 60 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Screened single core cablesThin wall thickness types1.8/3kV, 3.6/6kV
ApplicationsStrictly halogen free, all these wires combine the advantages of reduced size, lightweight, high chemical resistance, high mechanical properties. They are recommended for installation indoor or outdoor of railway vehicles for power supply.
Current carrying capacity according to EN 50343.
Cabling rules according to EN 50355.
Construction1. Conductor
Flexible stranded tinned copperClass 5 acc. to IEC 60228Covered with separate tape (Optional)
2. InsulationSpecial cross-linked compoundType EI 109 acc. to EN 50264-1Color: Black
3. ConductorTinned copper wires braid
4. SheathSpecial cross-linked compoundType EM 104, acc. toEN 50264-1Inside covered with optional tapesColor: Black
(N)SHXAFCOE
AmbientTemperature-40°C to 85°C
GoodResistanceto UV & humidity
Goodchemicalresistance
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
Page 61 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. Marking: KF2U 120 SHXAFCOE 3600V《Section》MM S NEXANS 448 week/year 2. Other cross section on request
Pow
er c
able
s
Page 62 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
FLAMEX SI – EN 50382-2 – 3600V –《section》– Hazard Level – 120°C – XZ – NEXANS – 448 – Week/Year
Standards
EN 50382-2 / EN 45545-2 / BS 6853 / NFPA130
Single core jumpersFLAMEX® SI 120℃ types3.6/6kV
ApplicationsThese wires combine the advantages of strictly halogen free, fire retardant, low smoke fume with a high performance insulation system. They are recommended for high temperature applications outside of the railway vehicles, between cars or between cars and bogies as power jumpers.
Cabling rules acc. to EN 50355.
Current carrying capacity acc. to EN 50343.
Construction1. Conductor
Extra flexible stranded tinned copperClass 6 acc. to IEC 60228Covered with separate tape (Optional)
2. InsulationSpecial cross-linked, halogen freeSilicone rubberColor: Black
3. Mechanical reinforcementHalogen free textile braid Included in insulation
EN 50382
AmbientTemperature-50°C to 115°C
GoodResistanceto UV & humidity
GoodResistance to impacts
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
FLA
MEX
SI 1
20°C
Jum
per
Note:X – Class 6 conductorsZ – Mechanical reinforcement
Page 65 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
FLAMEX SI – EN 50382-2 – 3600V –《section》– Hazard Level – 150°C – XZ – NEXANS – 448 – Week/Year
Standards
EN 50382-2 / EN 45545-2 / BS 6853
Single core jumpersFLAMEX® SI 150℃ types3.6/6kV AC
ApplicationsThese wires combine the advantages of strictly halogen free, fire retardant, low smoke fume with a high performance insulation system. They are recommended for high temperature applications outside of the railway vehicles, between cars or between cars and bogies as power jumpers.
Current carrying capacity acc. to EN 50343.
Cabling rules acc. to EN 50355.
Construction1. Conductor
Extra flexible stranded plain copperClass 6 acc. to IEC 60228Covered with separate tape (Optional)
3. Mechanical reinforcementHalogen free textile braid Included in insulation
EN 50382
AmbientTemperature-50°C to 145°C
GoodResistanceto UV & humidity
GoodResistance to impacts
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
Note:X – Class 6 conductorsZ – Mechanical reinforcement
Page 69 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
ApplicationsNexans can provide a better solution of jumper cables which are customized for power and data transmission between cars, cars and bogies.
Main characteristicsJumper cables are available in every type of construction according to customer's specifications:
- with single core and multi core (unscreened and unsheathed or screened and sheathed).- with coaxial and data bus cables
• Extra flexibility (class 6 stranded conductor).• High reliability: long life guarantee.• Excellent mechanical and chemical resistance (the same solution as power
jumpers for the outer jacket).• Operating voltage: from 250 to 3600 Volts.
Standards and specificationCustomized jumper cables strictly conform to the following standards:
All internal insulation of low voltage wires: NF F 63-808, EN 50306All internal insulation of power cables: EN 50264, EN 50382, NF F 63-826, NF F 63-827The external sheath of all jumpers: EN 50264, EN 50382, NF F 63-827 NF F 63-296
Customized jumpers
AmbientTemperature-40°C to 85°C
GoodResistanceto UV & humidity
GoodResistance to impacts
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
Page 73 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Highly flexible power jumper with overall EMC screen. Silicone rubber insulation and sheath.Overall diameter: 37~41mm
Power jumpers (48 cores)44x1.5mm2 + 4x2.5mm2
Highly flexible power jumper without screen.Special compound insulation and silicone rubber sheath. Overall diameter: 36~40mm
Other constructionThe examples represented here is just an overview of our expertise. Our development and design engineers are at your disposal to provide their experience in customizing any of our products to meet your requirements.
Page 74 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
EN 45545-2 / BS 6853 / NFPA130 / UNI CEI 11170-3 / EN 50200
Single and multi core cablesFLAMEX Z FR and 4GKW-EN FR300/500V or 0.6/1kV or 1.8/3kV AC
ApplicationsStrictly halogen free. these wires combine the advantages of reduced size, lightweight, high chemical resistance, high mechanical properties. They are recommended for installation in railway vehicles for emergency application.Current carrying capacity according to EN 50343.
Cabling rules according to EN 50355.
Circuit integrity according to EN 50200.
Construction1. Conductor
Flexible stranded tinned copperClass 5 acc. to IEC 60228Covered with MICA tape
2. InsulationSpecial cross-linked compoundType EI 109 or EI 110 acc. to EN 50264-1
3. SheathSpecial cross-linked compoundColor: Black
Fire resistant
AmbientTemperature-40°C to 85°C
GoodResistanceto UV & humidity
Goodchemicalresistance
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
Page 77 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. Marking: FLAMEX Z FR EN 50264-3-1 600V 《cross section》 M PH120 NEXANS 448 – week/year 2. Multi core fire resistant cable on request
EN
502
64-3
-1Fi
re re
sist
ant c
able
s
Page 78 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. Marking: < 25mm2 :KF2U 120 HXAFOE FR 1800V 《Section》 OM EN 50200 PH120 NEXANS 448 + ww/yy≥ 25mm2 :4GKW-EN FR 1.8/3kV EN 50264-3-1 1800V 《Section》 OM EN 50200 PH120 NEXANS 448+ ww/yy
Page 79 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. Marking: FLAMEX Z FR EN 50264-3-2 300V 《n》x 《cross section》 M PH120 NEXANS 448 – week/year 2. Core identification: print numbers
Note: 1. Marking: FLAMEX Z FR EN 50264-3-2 300V 《n》x 《cross section》 MM S PH120 NEXANS 448 – week/year 2. Core identification: print numbers
Page 80 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Conductor at normal operation ≤ 90°C / 250,000 h ≤ 120°C / 20,000 h
Conductor under short-circuit conditions(tinned) ≤ 250°C / 5 s
Operating in cold
Min. permissible ambient temperature ≥ -40°C
Min. bending radii
D < 12 D ≥ 12Fixed installation ≥ 3D ≥ 4DFree moved ≥ 4D ≥ 5DD = cable Ø (mm)
Page 81 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
ApplicationsThese data cables are halogen free, flame retardant, low smoke emission and low toxicity, good EMC performance. They are recommended for train communication network (TCN) and multimedia transmission in railway vehicles where good fire protection level and data transmission are required.
Construction1. Conductor
Flexible stranded tinned copper
2. InsulationHigh performance foamed PE or PECabling with optional fillers and tape
4. SheathSpecial cross-linked compoundEM 104 according to EN 50264-1
Data bus
AmbientTemperature-40°C to 75°C
GoodResistanceto UV & humidity
Goodchemicalresistance
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
Page 83 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. Other cross section pairs and quads on request 2. A quad can be used as two pairs. The opposite two cores are one pair 3. Core identification: two cores: white , black Four cores: Red, White, Black, Yellow
Characteristic Impedance (120±12) Ω 0.75 MHz to 3 MHz
Attenuation < 1.5 dB/100m at 1.5 MHz < 2.0 dB/100m at 3 MHz
Capacitance between cores ≤ 46 pF/m at 1.5 MHzCapacitance unbalance to shield ≤ 1.5 pF/m at 1.5 MHzNear end cross talk (NEXT) (quad cables) > 55 dB 0.75 MHz to 3 MHz (4 cores)Transfer impedance < 20 mΩ at 20 MHzDifferential transfer impedance < 2.0 mΩ/mVoltage test of insulation 1000 VDC 50 Hz 1 min
WTB
, MV
B &
CA
NB
US
Dat
a ca
bles
Page 84 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. Other cross section pairs and quads on request 2. Detail color information in corresponding specification 3. Core identification: white , black
Characteristic Impedance (120±12) Ω 0.5 MHz to 2 MHz
Attenuation < 1.0 dB/100m at 1.0 MHz < 1.4 dB/100m at 2.0 MHz
Capacitance between cores ≤ 65 pF/m at 1.0 MHzCapacitance unbalance to shield ≤ 1.5 pF/m at 1.0 MHzTransfer impedance < 20 mΩ at 20 MHzVoltage test of insulation 1000 VDC 50 Hz 1 min
Page 85 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Note: 1. Other cross section pairs on request 2. The core is according to EN 50306-2 3. Core identification: two cores: Blue and Red One core: white or Black
Characteristic Impedance (120±12) Ω 0.75 MHz to 3 MHz
Attenuation < 1.25 dB/100m at 1.0 MHz < 2.2 dB/100m at 3.0 MHz
Capacitance between cores ≤ 46 pF/m at 1.5 MHzCapacitance unbalance to shield ≤ 1.5 pF/m at 1.5 MHzTransfer impedance < 20 mΩ at 20 MHzVoltage test of insulation 1000 VDC 50 Hz 1 min
WTB
, MV
B &
CA
NB
US
Dat
a ca
bles
Page 86 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
ApplicationsNexans provides Ethernet cables for on-board railway equipments. These cables are adapted for data transmission up to 100 MHz, with performance close to that of 'CAT5/CAT5e' cables to meet ECN and ETB network requirements. Meanwhile using the FLAMEX technology, these halogen free cables are intended for applications where flame retardancy is required. In addition, Nexans' experience in the design of shielding technology enables us to propose all constructions with high EMC protection. They are particularly recommended for the cabling of rolling stock applications.
Construction1. Conductor
Flexible stranded tinned copper
2. InsulationSpecial high performance compoundCabling with optional fillers and tape
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
mm2 mm mm mm mm kg/km MJ/km5090204500 50507010400200 2x2x0.25 0.65 1.25 6.3 6.7 49 547 BK —5090202800 50507010400100 2x2x0.5 0.9 1.9 9.2 10.2 102 1080 BK —5090210100 50507030400200 2x2xAWG22 0.73 1.55 6.0 6.6 68 569 BK √5055203900 50503010800100 4x2xAWG26 0.48 0.9 5.0 5.8 34 440 BK —5000216200 53101040800000 4x2xAWG22 0.73 1.53 8.5 9.5 96.3 882 BK —5055204000 50503020800100 4x2x0.5 0.9 1.78 9.4 10.4 148 1598 BK —5000205500 50507010200400 2x1.5 1.61 3.4 8.7 9.5 93 680 BK —
CAT6 100 OHMTechnical data
TYPE NO. Crosssection
Nom. ØConductor
Nom. Øinsulation
Overall Ø Average Weight
Fireload
approx. Color InventoryOld New
Min. Max.
mm2 mm mm mm mm kg/km MJ/km5068201200 53101170800100 4x2xAWG26 0.48 1.02 5.7 6.5 35.5 382 BK —5065200500 53101170800300 4x2xAWG23 0.58 1.35 7.9 8.5 72 771 BK —
CAT7 100 OHMTechnical data
TYPE NO. Crosssection
Nom. ØConductor
Nom. Øinsulation
Overall Ø Average Weight
Fireload
approx. Color InventoryOld New
Min. Max.
mm2 mm mm mm mm kg/km MJ/km5200402200 53101230800000 4x2xAWG24 1.0 1.55 9.3 10.3 103 1181 BK —5200405000 53101320800200 4x2xAWG24 1.0 1.30 7.9 8.6 80 908 BK —
CAT6A 100 OHMTechnical data
TYPE NO. Crosssection
Nom. ØConductor
Nom. Øinsulation
Overall Ø Average Weight
Fireload
approx. Color InventoryOld New
Min. Max.
mm2 mm mm mm mm kg/km MJ/km5063201100 53101410800700 4x2xAWG26 0.48 1.03 5.5 6.1 32.5 342 BK —
Note: Core identification : Detail color information in corresponding specification
Note: Core identification : Detail color information in corresponding specification
Note: Core identification : Detail color information in corresponding specification
Note: Core identification : Detail color information in corresponding specification
WTB
, MV
B &
CA
NB
US
Dat
a ca
bles
Page 88 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
CAT5/5e CAT6 CAT 6A CAT 7100±15 1 to 100 MHz 100±15 1 to 250 MHz 100±15 1to 150 MHz 100±15 4 to 1000 MHz 100±22 150 to 500MHz 100±22 100 to 250MHz 100±25 250 to 600 MHz
< 2.0 at 1.0 MHz < 5.68 at 1.0 MHz < 2.08 at 1.0 MHz <2.7 at 1.0 MHz< 21.3 at 100 MHz < 49.27 at 250 MHz < 45.26 at 500 MHz <75.5 at 600 MHz
> 20.0 at 1 MHz > 20.0 at 1 MHz > 20.0 at 1 MHz > 23.0 at 4 MHz> 19.0 at 100 MHz > 17.3 at 100 MHz > 17.3 at 500 MHz > 15.6 at 600 MHz
≤ 56 pF/m at 1 kHz ≤56nF/m at 1kHz ≤56nF/m at 1kHz ≤55nF/km at 800Hz
≤ 1.6 pF/m at 1 kHz ≤3.3pF/m at 1kHz ≤1.6pF/m at 1kHz ≤110nF/km at 800Hz
> 62.3 at 1 MHz > 74.3 at 1 MHz > 75 at 1 MHz > 75 at 4 MHz
> 32.3 at 100 MHz > 38.3 at 250 MHz >34.8 at 500 MHz >60.7 at 600 MHz
1000 V DC 1 min 1000 V DC 1 min 1000 V DC 1 min 1000 V DC 1 min
Characteristic Impedance:
(Ω)
Attenuation: (dB/100m)
Return loss:(dB)
Capacitance (core to core):
Capacitance(core to screen):
Near end cross talk (NEXT):
(dB)
Voltage test of insulation
Page 89 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
ApplicationsFor inside and outside use in railway vehicles. Installation in cable ducts, tubes. On request available: completely pre-assembled flexible cables with plugs and sealing ends, electrically tested.
Current carrying capacity acc. to EN 50343 and EN 50355 as well as VDE 0298 part 5.
Construction1. Conductor
Flexible stranded tinned copper Class 5 acc. to IEC 60228
2. Conductor screenSemi-conductive compound
3. InsulationSpecial cross-linked compoundEI 105 according to EN 50264-1
6. SheathSpecial cross-linked compound Type EM 104 acc. to EN 50264-1Color: Black
Roof cable
AmbientTemperature-40°C to 85°C
GoodResistanceto UV & humidity
Goodchemicalresistance
Flameretardant
Low Smoke No corrosive Non-Toxic Halogen free
(N)T
MC
GC
HX
OE
Nex
an
s
Page 91 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
mm2 mm mm mm mm kg/km MJ/km79470574 50 16 29 34 35 2100 25200 BK —79470581 70 16 31 36 38 2300 26600 BK —79470575 95 16 32 38 40 2500 28800 BK —79470576 150 16 36 41 43 3200 36000 BK —79470577 240 25 40 45 48 4300 39600 BK —
Note: Other cross section on request. Conductor information refer to Annex
Roo
f cab
les
Page 92 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Requirements of IEC 60228 Conductor information for power cables
Nominal cross-sectional area Maximum wires
conductormm2
Maximum diameter ofwires in
conductormm
Maximum resistance of conductor at 20 °CΩ/km
Plain wires Metal-coated wires
CL 5 CL 6 CL 5 CL 6 CL 5 CL 6
0.5 0.21 0.16 39 39 40.1 40.1
0.75 0.21 0.16 26 26 26.7 26.7
1 0.21 0.16 19.5 19.5 20 20
1.5 0.26 0.16 13.3 13.3 13.7 13.7
2.5 0.26 0.16 7.98 7.98 8.21 8.21
4 0.31 0.16 4.95 4.95 5.09 5.09
6 0.31 0.21 3.3 3.3 3.39 3.39
10 0.41 0.21 1.91 1.91 1.95 1.95
16 0.41 0.21 1.21 1.21 1.24 1.24
25 0.41 0.21 0.78 0.78 0.795 0.795
35 0.41 0.21 0.554 0.554 0.565 0.565
50 0.41 0.31 0.386 0.386 0.393 0.393
70 0.51 0.31 0.272 0.272 0.277 0.277
95 0.51 0.31 0.206 0.206 0.21 0.21
120 0.51 0.31 0.161 0.161 0.164 0.164
150 0.51 0.31 0.129 0.129 0.132 0.132
185 0.51 0.41 0.106 0.106 0.108 0.108
240 0.51 0.41 0.0801 0.0801 0.0817 0.0817
300 0.51 0.41 0.0641 0.0641 0.0654 0.0654
400 0.51 0.0486 0.0495
For the conductor information of EN 50306 cables, please refer to table 1 of EN 50306-2:2002
Page 95 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
In accordance with EN 50343Current rating of single core cables in free air without any corrective factor
Cross section(mm2)
90°C 120°C 150°C
EN 50306 EN 50382 EN 50382
0.5 14 — —
0.75 16 — —
1.0 20 24.5 28.1
1.5 25 31 35.2
2.5 33 40 46.5
4 46 57 64.7
6 60 74 84
10 85 105 119
16 110 136 154
25 150 185 198
35 190 235 244
50 240 297 303
70 300 371 422
95 360 445 506
120 425 526 598
150 490 606 689
185 560 693 788
240 675 835 950
300 775 959 1091
400 950 1117 1337
Note: Icable > Iload / (k1 x k2 x k3 x k4 x k5) k3, k4 are recommended as 1.0
EN cables current rating
Tech
nica
l dat
a
Page 96 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Derating coefficient in other ambient temperature (K1)
AmbientTemperature (T)
90°C 105°C 120°C 150°C
EN 50306EN 50264 EN 50306 EN 50382 EN 50382
35°C 1.11 1.08 1.06 1.05
40°C 1.05 1.04 1.03 1.02
45°C 1.00 1.00 1.00 1.00
50°C 0.94 0.96 0.97 0.98
55°C 0.88 0.91 0.93 0.95
60°C 0.82 0.87 0.89 0.93
65°C 0.75 0.82 0.86 0.90
70°C 0.67 0.76 0.82 0.87
75°C 0.58 0.71 0.77 0.85
80°C 0.47 0.65 0.73 0.82
85°C 0.33 0.58 0.68 0.79
90°C — 0.50 0.63 0.76
95°C — 0.41 0.58 0.72
100°C — — 0.52 0.69
105°C — — 0.45 0.65
115°C — — 0.26 0.58
125°C — — — 0.49
135°C — — — 0.38
145°C — — — 0.22
Note: The correction factor k1 for the expected ambient temperature shall be calculated according to the following formula:
Tc(max): the maximum operation temperature of conductor ( °C ) T: ambient temperature ( °C )
45k
(max)
(max)1 −
−=
c
c
TTT
Page 97 / 98
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
In accordance with EN 50355Recommended short circuit current ratings for rolling stock cables
Conductor cross-sectionEN50264 EN 50382
Short circuit current rating 200°C
Short circuit current rating 250°C Short circuit current rating 350°C
mm2 A A A
1 122 126 146
1.5 183 189 219
2.5 305 315 365
4 488 504 584
6 732 756 876
10 1 220 1 260 1 460
16 1 950 2 016 2 336
25 3 050 3 150 3 650
35 4 270 4 410 5 110
50 6 100 6 300 7 300
70 8 540 8 820 10 220
95 11 590 11 970 13 870
120 14 640 15 120 17 520
150 18 300 18 900 21 900
185 22 570 23 310 27 010
240 29 280 30 240 35 040
300 36 600 37 800 43 800
400 48 800 50 400 58 400
EN cables short circuit current rating
Note: The tabulated values of short circuit current are applicable to standard wall cables to EN 50264 and EN 50382 and are based upon a duration of current flow of 1 s. Circuit current under other duration of current flow following the formula:
A: Short circuit current rating during 1 sec. (A)It: Short circuit current for a given period (A)t: Duration of the short circuit (sec)