Civil Engineer: Surveyor: RODDEN SQUARE APARTMENTS CITY OF CHARLOTTE MECKLENBURG COUNTY, NORTH CAROLINA The Curry Engineering Group, PLLC NC License # P-0799 205 S. Fuquay Ave Fuquay-Varina, NC 27526 919.552.0849 (o) Contact: Zak Shipman, PE [email protected]SITE CONSTRUCTION DRAWINGS REGULATORY REVIEW SET ISSUED 12-17-2015 REVISED 03-31-2016 REVISED 05-19-16 REVISED 06-20-16 ALLEN GEOMATICS PO Box 89 Advance, NC 27006 336.782.3796 Contact: Mr. Jeff Allen, PLS [email protected]Developer: Connelly Builders, Inc. 125 Old Chapin Road Lexington, SC 29072 803.798.0572 Contact: Mr. Kevin Connelly [email protected]SCALE: NTS LOCATION MAP Curry C U R R Y E N G I N E E R S N O R T H C A R O L I N A EST. 10 NC LIC. NO. P-0799 Z:\PROJECTS FOLDER-ZEBULON\2015\2015-027-RODDEN SQUARE APARTMENTS\PLANS\CONSTRUCTION DRAWINGS\SHEET DRAWINGS\C-00-COVER.DWG PLOTTED: 8/9/2016 3:05 PM RODDEN SQUARE APARTMENTS-CHARLOTTE, NC CIVIL SERIES DRAWING ABBREVIATIONS: @/-AT AC-ACRE AFG- ABOVE FINISHED GRADE APPR-APPROXIMATE ASSY-ASSEMBLY B/C-BOTTOM OF CURB BOC-BACK OF CURB B/L-BASE LINE BM-BOOK OF MAPS BMP-BEST MANAGEMENT PRACTICE BW-BOTTOM OF WALL CB-CATCH BASIN C&G-CURB AND GUTTER C/L-CENTERLINE CL-CLASS CMP-CORRUGATED METAL PIPE CO-CLEANOUT COMM-COMMUNICATIONS CONC-CONCRETE CONN-CONNECTION CY-CUBIC YARD DB-DEED BOOK DCV-DOUBLE CHECK VALVE DDCV-DOUBLE DECTECTOR CHECK VALVE DI-DROP INLET DIP-DUCTILE IRON PIPE DR-DRIVEWAY MECH-MECHANICAL MH-MANHOLE MIN-MINIMUM MJ-MECHANICAL JOINT NIC-NOT IN CONTRACT OHE-OVERHEAD ELECTRIC OHP-OVERHEAD POWER OHT-OVERHEAD TELEPHONE PB-PLAT BOOK PC-POINT OF CURVATURE PED-PEDESTRIAN PG-PAGE PH-PHASE PI-POINT OF INTERSECTION PIV-POST INDICATOR VALVE PKG-PARKING P/L-PROPERTY LINE PS-PUMP STATION PT-POINT OF TANGENCY PP-POWER POLE PVC-POLYVINYL CHLORIDE PVMT-PAVEMENT PWR-POWER R-RADIUS RD-ROOF DRAIN RJ-RESTRAINTED JOINT RPZ-REDUCED PRESSURE ZONE DS-DOWNSPOUT EA-EACH EIP-EXISTING IRON PIPE ELEC-ELECTRICAL E/P-EDGE OF PAVEMENT EX-EXISTING F/C-FACE OF CURB FDC-FIRE DEPARTMENT CONNECTION FFE-FINISHED FLOOR ELEVATION FG-FINISHED GRADE FH-FIRE HYDRANT F/L-FLOW LINE FM-FORCE MAIN FT-FOOT G-GAS GND-GROUND GV-GATE VALVE HDPE-HIGH DENSITY POLYETHYLENE HORIZ-HORIZONTAL IN-INCHES INV-INVERT IP-IRON PIPE IPS-IRON PIPE SET L-LENGTH LF-LINEAR FOOT LP-LIGHT POLE LS-LIFT STATION R/W-RIGHT OF WAY REQD-REQUIRED RCP-REINFORCED CONCRETE PIPE SAN-SANITARY SEWER SDWK-SIDEWALK SF-SQUARE FOOT SPT-SPOT GRADE SS-SANITARY SEWER STA-STATION STD-STANDARD STM-STORM STMH-STORM SEWER MANHOLE SWM-STORMWATER MANAGEMENT T-TELEPHONE T/C-TOP OF CURB TCM-TELEPHONE MANHOLE TS&V-TAPPING SLEEVE AND VALVE UGE-UNDERGROUND ELECTRIC UNK-UNKNOWN UP-UTILITY POLE VAR-VARIABLE VERT-VERTICAL W/-WITH WM-WATER METER W/O-WITHOUT W/L-WATERLINE WSEL-WATER SERVICE ELEVATION WV-WATER VALVE SURVEY DATUM INFORMATION: HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NAVD88 SANITARY SEWER EXISTING SANITARY SEWER SANITARY SEWER MAIN SEWER MANHOLE CLEANOUT EXISTING CLEANOUT EX. SEWER MANHOLE WATER EXISTING WATER LINE WATERLINE PROPOSED WATER VALVE POST INDICATOR VALVE (PIV) EX. WATER METER EX. VALVE WATER METER EX. FIRE HYDRANT FIRE HYDRANT REDUCER FITTING PLUG FITTING WATERLINE TEE WATERLINE CROSS FIRE DEPARTMENT CONNECTION (FDC) WATERLINE BLOWOFF EX. WELL CASING NATURAL GAS EX. GAS LINE GAS LINE EX. GAS VALVE EX. GAS METER MISCELLANEOUS UTILITIES EX. LIGHT POLE EX. LIGHT (WALL PACK) PROPOSED LIGHT POLE EX. UTILITY POLE UTILITY POLE EX. GUY WIRE EX. ELECTRICAL METER EX. OVERHEAD ELECTRIC LINE PROPOSED OVERHEAD ELECTRIC LINE EX. UNDERGROUND ELECTRIC LINE PROPOSED UNDERGROUND ELECTRIC LINE EX. TELEPHONE PEDESTAL TELEPHONE PEDESTAL EX. TELEPHONE MANHOLE EX. OVERHEAD TELEPHONE LINE OVERHEAD TELEPHONE LINE EX. OVERHEAD FIBER LINE OVERHEAD FIBER LINE EX. CABLE PEDESTAL EX. OVERHEAD COMMUNICATIONS LINE OVERHEAD COMMUNICATIONS LINE EX. UNDERGROUND COMMUNICATIONS LINE UNDERGROUND COMMUNICATIONS LINE SITE DEVELOPMENT EX. STORM SEWER PIPE PROPOSED STORM SEWER EX. STORM STRUCTURE CATCH BASIN DROP INLET EX. STORM SEWER MANHOLE STORM SEWER MANHOLE EX. ROOF DRAIN LEADER ROOF DRAIN LEADER EX. ROOF DRAIN DOWNSPOUT ROOF DRAIN DOWNSPOUT EX. CURB AND GUTTER CURB AND GUTTER PROPERTY LINE EXISTING PROPERTY LINE EX. SHRUB BENCHMARK AND/OR SURVEY CONTROL MARKER SOIL BORING LOCATION LIMITS OF DISTURBANCE EX. TREE EX. FENCE PROPOSED FENCE EX. TOPOGRAPHIC CONTOUR G PROPOSED TOPOGRAPHIC CONTOUR PROPOSED SPOT ELEVATION EX. SIGN SIGN BOLLARD PROPERTY MARKER/IRON PIPE EX. SURVEY MONUMENT W W SS SAN G RD RD FG XXX B-8 S D * * S M M OHP OHP UGP UGP T T T OHT OHT OFO OFO C OHC OHC UGC UGC LEGEND EX. OVERHEAD UTILITY LINE-MULTIPLE UTILITIES OHU Architect: Planworx Architecture, PA 5711 Six Forks Road, Suite 100 Raleigh, NC 27609 919.846.8100 Contact: Mr. Robert Clifford [email protected]C-00 COVER SHEET SITE CIVIL DRAWING INDEX: COVER SHEET C-00 EXISTING CONDITIONS SURVEY C-01 OVERALL SITE LAYOUT PLAN C-03 DEMOLITION PLAN C-02 PARTIAL SITE LAYOUT PLAN I C-04 PARTIAL SITE LAYOUT PLAN II C-05 OVERALL SITE UTILITY PLAN C-06 PARTIAL SITE UTILITY PLAN I C-07 PARTIAL SITE UTILITY PLAN II C-08 PARTIAL GRADING, DRAINAGE, & STORMWATER PLAN I C-10 PARTIAL GRADING, DRAINAGE, & STORMWATER PLAN II C-11 ROOF DRAINAGE PLAN C-12 SITE HYDROLOGY ANALYSIS PLAN C-13 TYPICAL ROADWAY CROSS SECTIONS C-17 MALLARD CREEK ROAD CROSS SECTIONS C-18 OVERALL GRADING, DRAINAGE, & STORMWATER PLAN C-09 OVERALL LANDSCAPE PLAN L-01 PARTIAL LANDSCAPING PLAN I L-02 PARTIAL LANDSCAPING PLAN II L-03 OFFSITE ROAD WIDENING PLAN-MALLARD CREEK RD. C-15 RODDEN MILL COURT PLAN & PROFILE C-23 DOLBY CREEK PLACE PLAN & PROFILE C-24 OVERALL EROSION & SEDIMENT CONTROL PLAN-PH. 1 C-26 NOTES AND DETAILS D-01 NOTES AND DETAILS D-02 NOTES AND DETAILS D-03 NOTES AND DETAILS D-04 NOTES AND DETAILS D-05 NOTES AND DETAILS D-06 NOTES AND DETAILS D-07 NOTES AND DETAILS D-08 NOTES AND DETAILS D-09 NOTES AND DETAILS D-10 NOTES AND DETAILS D-11 STORMWATER BMP DETAILS C-14 MALLARD CREEK ROAD CROSS SECTIONS C-19 SITE DISTANCE PLAN & PROFILE-MALLARD CREEK ROAD C-20 MALLARD CREEK ROAD WORK ZONE TRAFFIC CONTROL C-21 MALLARD CREEK ROAD WORK ZONE TRAFFIC CONTROL C-22 PARTIAL EROSION & SEDIMENT CONTROL PLAN-PH. 1 C-27 PARTIAL EROSION & SEDIMENT CONTROL PLAN-PH. I C-28 OVERALL EROSION & SEDIMENT CONTROL PLAN-PH. II C-29 PARTIAL EROSION & SEDIMENT CONTROL PLAN-PH. II C-30 PARTIAL EROSION & SEDIMENT CONTROL PLAN-PH. II C-31 TREE SAVE AREA SURVEY C-32 TREE SAVE AERIAL PHOTOGRAPH C-33 LANDSCAPING NOTES AND DETAILS L-04 EROSION CONTROL NOTES C-25 TEMPORARY DRIVEWAY PLAN C-16
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.