ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30MDate: 05-02-2012
Designer: Syaiful Fikri
CalcuLuX Road 7.6.1.0
The nominal values shown in this report are the result of precision calculations, based upon precisely positioned luminaires in a fixedrelationship to each other and to the area under examination. In practice the values may vary due to tolerances on luminaires, luminairepositioning, reflection properties and electrical supply.
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
1. Project Description
1.1 3-D Project Overview
B BRP372 LED126NW 138W 22
B
B
B
BBBBBB
B
B
B
BBBBBB
X
YZ
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 2/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
1.2 Top Project Overview
B BRP372 LED126NW 138W 22
-22 -17 -12 -7 -2 3 8 13 18
X(m)
-6-1
49
1419
2429
3439
44Y
(m)
B
B
B
B
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 3/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
2. Summary
2.1 Main Road
Luminaire Type : BRP372 LED126NW 138W 220-240V DM2ELamp Type : 1 * Luxeon R x64LEDs Ra75.1Lamp Flux : 12623 lumenTilt90 (T) : 5.0 degGrid Method : CEN LuminanceProject Maintenance Factor : 0.90
T
O
H
WW C
S
Carriageway : Dual CarriagewayCentral Reserve (C) : 3.00 mRoad Width (W) : 7.00 mNumber of Lanes : 3Reflection Table : CIE C1Q0 of Table : 0.100Maintenance Factor : 0.90Installation : Twin CentralHeight (H) : 13.00 mSpacing (S) : 40.00 mOverhang (O) : 1.50 m
Overall quality figures for the above road scheme.
LuminanceAverage = 1.70 cd/m2Minimum = 1.18 cd/m2Maximum = 2.58 cd/m2Minimum/Maximum = 0.45Minimum/Average = 0.69Ul = 0.60
GlareTI = 5.5 %
Horizontal IlluminanceAverage = 16.8 luxMinimum = 10.5 luxMaximum = 29.3 luxMinimum/Maximum = 0.36
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 4/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
3. Calculation Results
3.1 Main L (O1): Graphical Table
TI ( 1.17,-31.63, 1.50) = 5.5%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O1) (1.17,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.70 0.69 0.45 0.90
B BRP372 LED126NW 138W 22
-18 -13 -8 -3 2 7 12 17 22
X(m)
-41
611
1621
2631
3641
Y(m
)
B
B
B
B
1.8
1.7
1.5
1.4
1.3
1.2
1.2
1.2
1.2
1.4
1.5
1.6
1.7
1.8
1.9
1.7
1.6
1.4
1.4
1.2
1.2
1.2
1.3
1.4
1.5
1.7
1.8
1.9
2.0
1.8
1.6
1.5
1.4
1.3
1.2
1.3
1.3
1.5
1.5
1.7
1.9
2.0
2.1
1.9
1.7
1.5
1.4
1.3
1.3
1.3
1.4
1.5
1.6
1.8
2.0
2.1
2.2
2.0
1.7
1.5
1.5
1.4
1.3
1.4
1.4
1.6
1.7
1.9
2.1
2.2
2.3
2.1
1.8
1.6
1.5
1.4
1.4
1.4
1.5
1.6
1.7
1.9
2.2
2.3
2.3
2.1
1.9
1.7
1.5
1.4
1.4
1.5
1.5
1.7
1.8
2.0
2.2
2.4
2.4
2.2
1.9
1.7
1.6
1.5
1.5
1.5
1.6
1.7
1.9
2.1
2.3
2.5
2.6
2.4
2.1
1.9
1.7
1.6
1.5
1.6
1.6
1.8
2.0
2.2
2.5
2.6
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 5/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
3.2 Main L (O1): Iso Contour
TI ( 1.17,-31.63, 1.50) = 5.5%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O1) (1.17,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.70 0.69 0.45 0.90
B BRP372 LED126NW 138W 22
-18 -13 -8 -3 2 7 12 17 22
X(m)
-41
611
1621
2631
3641
Y(m
) 1.2
51.
5
1.5
1.75
1.75
2
22.
252.252.
5
2.5
B
B
B
B
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 6/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
3.3 Main L (O1): Filled Iso Contour
TI ( 1.17,-31.63, 1.50) = 5.5%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O1) (1.17,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.70 0.69 0.45 0.90
B BRP372 LED126NW 138W 22
2.5
2.25
2
1.75
1.5
1.25
-12 -7 -2 3 8 13 18
X(m)
-41
611
1621
2631
3641
Y(m
)
B
B
B
B
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 7/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
3.4 Main L (O2): Graphical Table
TI ( 3.50,-31.63, 1.50) = 5.3%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O2) (3.50,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.73 0.70 0.46 0.90
B BRP372 LED126NW 138W 22
-18 -13 -8 -3 2 7 12 17 22
X(m)
-41
611
1621
2631
3641
Y(m
)
B
B
B
B
1.8
1.7
1.5
1.4
1.4
1.2
1.2
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.8
1.6
1.4
1.4
1.3
1.2
1.2
1.3
1.5
1.5
1.7
1.8
1.9
2.0
1.8
1.7
1.5
1.4
1.3
1.3
1.3
1.3
1.5
1.6
1.8
1.9
2.1
2.1
1.9
1.7
1.5
1.5
1.3
1.3
1.3
1.4
1.5
1.6
1.8
2.0
2.2
2.2
2.0
1.8
1.6
1.5
1.4
1.4
1.4
1.4
1.6
1.7
1.9
2.1
2.2
2.3
2.1
1.8
1.6
1.5
1.4
1.4
1.4
1.5
1.6
1.7
2.0
2.2
2.3
2.3
2.1
1.9
1.7
1.6
1.5
1.4
1.5
1.5
1.7
1.8
2.0
2.3
2.4
2.4
2.2
1.9
1.7
1.6
1.5
1.5
1.5
1.6
1.7
1.9
2.1
2.3
2.4
2.6
2.3
2.1
1.8
1.7
1.6
1.5
1.6
1.6
1.8
2.0
2.2
2.5
2.6
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 8/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
3.5 Main L (O2): Iso Contour
TI ( 3.50,-31.63, 1.50) = 5.3%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O2) (3.50,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.73 0.70 0.46 0.90
B BRP372 LED126NW 138W 22
-18 -13 -8 -3 2 7 12 17 22
X(m)
-41
611
1621
2631
3641
Y(m
) 1.25
1.5
1.5
1.75
1.75
2
2
2
2.252.252.
5
2.5
B
B
B
B
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 9/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
3.6 Main L (O2): Filled Iso Contour
TI ( 3.50,-31.63, 1.50) = 5.3%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O2) (3.50,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.73 0.70 0.46 0.90
B BRP372 LED126NW 138W 22
2.5
2.25
2
1.75
1.5
1.25
-12 -7 -2 3 8 13 18
X(m)
-41
611
1621
2631
3641
Y(m
)
B
B
B
B
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 10/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
3.7 Main L (O3): Graphical Table
TI ( 5.83,-31.63, 1.50) = 5.0%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O3) (5.83,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.74 0.71 0.48 0.90
B BRP372 LED126NW 138W 22
-18 -13 -8 -3 2 7 12 17 22
X(m)
-41
611
1621
2631
3641
Y(m
)
B
B
B
B
1.8
1.7
1.6
1.4
1.4
1.3
1.2
1.3
1.3
1.5
1.5
1.7
1.8
1.9
1.9
1.8
1.6
1.5
1.4
1.3
1.3
1.3
1.3
1.5
1.6
1.7
1.9
2.0
2.1
1.9
1.7
1.5
1.5
1.3
1.3
1.3
1.4
1.5
1.6
1.8
2.0
2.1
2.2
2.0
1.7
1.6
1.5
1.4
1.3
1.4
1.4
1.6
1.7
1.9
2.1
2.2
2.2
2.0
1.8
1.6
1.5
1.4
1.4
1.4
1.5
1.6
1.7
1.9
2.2
2.3
2.3
2.1
1.8
1.6
1.5
1.4
1.4
1.4
1.5
1.7
1.8
2.0
2.2
2.3
2.3
2.1
1.8
1.7
1.6
1.5
1.4
1.5
1.5
1.7
1.8
2.0
2.2
2.3
2.4
2.2
1.9
1.7
1.6
1.5
1.5
1.5
1.6
1.7
1.9
2.1
2.3
2.4
2.5
2.3
2.0
1.8
1.7
1.6
1.5
1.6
1.6
1.8
2.0
2.2
2.4
2.6
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 11/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
3.8 Main L (O3): Iso Contour
TI ( 5.83,-31.63, 1.50) = 5.0%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O3) (5.83,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.74 0.71 0.48 0.90
B BRP372 LED126NW 138W 22
-18 -13 -8 -3 2 7 12 17 22
X(m)
-41
611
1621
2631
3641
Y(m
)
1.25
1.5
1.5
1.75
1.75
2
2
22.2
5
2.25
2.5
2.5
B
B
B
B
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 12/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
3.9 Main L (O3): Filled Iso Contour
TI ( 5.83,-31.63, 1.50) = 5.0%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O3) (5.83,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.74 0.71 0.48 0.90
B BRP372 LED126NW 138W 22
2.5
2.25
2
1.75
1.5
1.25
-12 -7 -2 3 8 13 18
X(m)
-41
611
1621
2631
3641
Y(m
)
B
B
B
B
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 13/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
3.10 Main Eh: Graphical Table
Grid : Main at Z = -0.00 mCalculation : Horizontal Illuminance (lux)
Average Min/Ave Min/Max Project maintenance factor 16.8 0.63 0.36 0.90
B BRP372 LED126NW 138W 22
-18 -13 -8 -3 2 7 12 17 22
X(m)
-6-1
49
1419
2429
3439
44Y
(m)
B
B
B
B
21
19
17
15
13
11
11
11
11
13
15
17
19
21
22
20
17
15
13
11
11
11
11
13
15
17
20
22
23
21
18
15
13
11
11
11
11
13
15
18
21
23
24
21
18
15
13
11
11
11
11
13
15
18
21
24
24
22
18
15
13
11
11
11
11
13
15
18
22
24
25
22
19
15
14
12
11
11
12
14
15
19
22
25
26
23
19
16
14
12
11
11
12
14
16
19
23
26
27
24
20
17
14
12
12
12
12
14
17
20
24
27
29
26
22
18
15
13
12
12
13
15
18
22
26
29
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 14/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
3.11 Main Eh: Iso Contour
Grid : Main at Z = -0.00 mCalculation : Horizontal Illuminance (lux)
Average Min/Ave Min/Max Project maintenance factor 16.8 0.63 0.36 0.90
B BRP372 LED126NW 138W 22
-18 -13 -8 -3 2 7 12 17 22
X(m)
-6-1
49
1419
2429
3439
44Y
(m)
15
15
20
20
25
25
B
B
B
B
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 15/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
3.12 Main Eh: Filled Iso Contour
Grid : Main at Z = -0.00 mCalculation : Horizontal Illuminance (lux)
Average Min/Ave Min/Max Project maintenance factor 16.8 0.63 0.36 0.90
B BRP372 LED126NW 138W 22
25
20
15
-12 -7 -2 3 8 13 18
X(m)
-6-1
49
1419
2429
3439
44Y
(m)
B
B
B
B
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 16/17
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012
4. Luminaire Details
4.1 Project Luminaires
Xceed Medium FOT Sample(64LED700)BRP372 LED126NW 138W 220-240V 1xLuxeon R x64LEDs Ra75.1/3934
Light output ratios DLOR : 1.00 ULOR : 0.00 TLOR : 1.00Ballast : 700mA Global DriverLamp flux : 12623 lmLuminaire wattage : 138.0 WMeasurement code : LVC1121498
Note: Luminaire data not from database.
750
750
0o 30o30o
60o 60o
90o 90o
120o 120o150o 150o180o
C = 180o C = 0o C = 270o C = 90o C = 195o Imax C = 15o
Luminous Intensity Diagram (candela/1000 lumen)
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 17/17