Rheem Classic Plus ® Series Two-Stage Multi-position Gas Furnaces FORM NO. G11-553 REV. 2 R96T- Series 96% A.F.U.E.†* Input Rates from 40 to 115 kBTU [11.72 to 33.71 kW] • 96% residential gas furnace CSA certified • 4 way multi-poise design • Two stages of operation to save energy and maintain optimal comfort level. • PlusOne ™ Diagnostics 7-Segment LED all units • PlusOne ™ Ignition System – DSI for reliability and longevity • PlusOne ™ Water Management System with patented Blocked Drain Sensor • Heat exchanger is removable for improved serviceability. Aluminized steel primary and stainless steel secondary con- struction provide maximum corrosion resistance and thermal fatigue reliability. • Low profile “34 inch” cabinet ideal for space constrained installations. • Blower Shelf design – serviceable in all furnace orientations • Pre marked hoses – insures proper system drainage • Vent with 2" or 3" PVC • Replaceable Collector box • Hemmed edges on cabinet and doors • Quarter turn fasteners for tool less access • Integrated control boards feature dip switches for easy system set up • Self priming condensate trap • Solid bottom included Air Gas Furnaces R96T Series ✝ A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. *Up to 96% A.F.U.E.
12
Embed
Rheem Classic Plus Series Two-Stage Multi-position Gas ...
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Rheem Classic Plus® Series Two-StageMulti-position Gas Furnaces
FORM NO. G11-553 REV. 2
R96T- Series96% A.F.U.E.†*Input Rates from 40 to 115 kBTU[11.72 to 33.71 kW]
• 96% residential gas furnace CSA certified • 4 way multi-poise design• Two stages of operation to save energy and maintain optimal
comfort level.• PlusOne™ Diagnostics 7-Segment LED all units• PlusOne™ Ignition System – DSI for reliability and longevity• PlusOne™ Water Management System with patented Blocked
Drain Sensor• Heat exchanger is removable for improved serviceability.
Aluminized steel primary and stainless steel secondary con-struction provide maximum corrosion resistance and thermalfatigue reliability.
• Low profile “34 inch” cabinet ideal for space constrainedinstallations.
• Blower Shelf design – serviceable in all furnace orientations• Pre marked hoses – insures proper system drainage• Vent with 2" or 3" PVC• Replaceable Collector box• Hemmed edges on cabinet and doors• Quarter turn fasteners for tool less access• Integrated control boards feature dip switches for easy
system set up• Self priming condensate trap• Solid bottom included
AirGas FurnacesR96T Series
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance withDepartment of Energy test procedures.
*Up to 96% A.F.U.E.
AirTable of ContentsR96T Series
2
TABLE OF CONTENTSStandard & Optional Equipment ......................................................................3
Physical Data & Specifications ........................................................................4
Model Number Identification ............................................................................5
STANDARD EQUIPMENTCompletely assembled and wired; blocked drain sensor, 7segment LED and marked hoses; heat exchanger; primary:aluminized steel, secondary: 29-4C stainless steel; 2 stageinduced draft; pressure switches; redundant 2 stage main gascontrol; blower compartment door safety switch; solid statetime on/off blower control; limit controls; manual shut-offvalve; 100% safety lock out; cool fan off delay; field selectableheat fan off delay; one hour automatic retry; power and self-test diagnostics; flame sense current diagnostics; electronicair cleaner connections; twinning (built-in) features; humidifierconnections; humidifier on/off delay; low speed continuous fanoption; single speed option for heating and cooling applica-tions; transformer; direct drive, multi-speed constant torqueelectrically commutated blower motor. Solid bottom. (Pleasenote: a thermostat is not included as standard equipment.)
OPTIONAL EQUIPMENTSide and bottom filter racks; return air cabinet for all sizes.NOTE: Furnace is not listed for use with fuels other than natural
or L.P. (propane) gas.All models can be converted by a qualified distributor or localservice dealer to use L.P. (propane) gas without changing burn-ers. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optionalaccessories from a parts distributor.For L.P. (propane) operation, refer to Conversion Kit Index Form.
WARNINGTHIS FURNACE IS NOT APPROVED
OR RECOMMENDEDFOR USE IN MOBILE HOMES
PRIMARY AND SECONDARYHEAT EXCHANGER
IN-SHOT BURNERS
PRESSURE SWITCHES
DRAFTINDUCER
CONTROLBOARD
CONSTANT TORQUEELECTRICALLYCOMMUTATED MOTOR
GAS VALVE AND MANIFOLD
DIRECT SPARK IGNITION &REMOTE SENSOR
REMOTESENSOR
BLOCKED DRAINSENSOR
AirPhysical Data & SpecificationsR96T Series
4
Physical Data and Specifications—Upflow ModelsU.S. and Canadian Models
MODEL NUMBERS R96TA0402317MSA R96TA0602317MSA R96TA0702317MSA R96TA0852521MSA R96TA1002521MSA R96TA1152524MSA
MOTOR FULL LOAD AMPS 6.4 6.4 6.4 10.6 10.6 10.6HEATING SPEED–HIGH FIRE MED MED MED MED-HIGH MED MEDHEATING SPEED–LOW FIRE LOW MED-LOW LOW MED-LOW LOW LOWCOOLING SPEED MED-HIGH MED-HIGH MED-HIGH HIGH HIGH HIGHMINIMUM EXT. STATICPRESSURE (IN. W.C.) [kPa] .18 [.045] .20 [.050] .23 [.057] .28 [.070] .28 [.070] .28 [.070]
AFUE ➂ 96.00% 96.00% 96.00% 96.00% 96.00% 96.00%NOTES: All models are 115V, 60HZ, 1 phase Gas connection size for all models is 1/2" [13 mm] N.P.T. ➀ Installation instructions for high altitude derate. ➁ Canadian installations only. ➂ In accordance with D.O.E. test procedures. *S=Standard ModelsNOTE: Standard model complies with California low nox requirements.
*A service clearance of at least 24" is recommended in front of all furnaces [ ] Designates Metric ConversionsSupply and return depicted as upflow configuration.Flange configuration will vary depending on installation orientation.
AirBlower Performance DataR96T Series
7
MODELBLOWER
SIZEIN. [mm]
MOTORH.P.[W]
SPEEDTAP
CFM [L/s] AIR DELIVERYEXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa]
** = Factory tap for Low Fire ** = Factory tap for Hi FireNOTE: The Technician/Installer must verify that the furnace is operating within the published rise range before completing the installation
[ ] Designates Metric Conversions.
AirAccessoriesR96T Series
8
FILTER RACK FILTER SIZES* INCHES [mm]
MODELRXGF-CB(UPFLOW/
HORIZONTAL)
RXGF-CD(UPFLOW)
RXGF-CC(DOWNFLOW)
R96TA040 153/4 x 25[400 x 635]
153/4 x 25[400 x 635]
12 x 20[305 x 508]
R96TA060 153/4 x 25[400 x 635]
153/4 x 25[400 x 635]
12 x 20[305 x 508]
R96TA070 153/4 x 25[400 x 635]
153/4 x 25[400 x 635]
12 x 20[305 x 508]
R96TA085 191/4 x 25[489 x 635]
153/4 x 25[400 x 635]
12 x 20[305 x 508]
R96TA100 191/4 x 25[489 x 635]
153/4 x 25[400 x 635]
12 x 20[305 x 508]
R96TA115 223/4 x 25[578 x 635]
153/4 x 25[400 x 635]
14 x 20[356 x 508]
FOR HIGH ALTITUDES:NOTE: For Canadian installations only, an optional derate (manifold
gas pressure reduction) method may be used to adjust thefurnace for altitude. See Installation Instructions for moreinformation. This optional method may NOT be used for U.S.installations. See installation instructions as appropriate orificechange is required.
L.P. CONVERSION KIT: RXGJ-FP34
CONDENSATE PUMP KIT: PROSTOCK & 1PCB151TUL
DOWNFLOW/HORIZONTAL CONVERSION KIT: RXGY-CK
DOWNFLOW/HORIZONTAL LEFT ZERO CLEARANCE CONVERSION KIT: RXGY-ZK
*Filter racks are shipped without filters.Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter.
AirLimited WarrantyR96T Series
9
GENERAL TERMS OF LIMITED WARRANTY*Rheem will furnish a replacement for any part of this productwhich fails in normal use and service within the applicableperiod stated, in accordance with the terms of the limited warranty.*For complete details of the Limited and Conditional Warranties, includingapplicable terms and conditions, contact your local contractor or theManufacturer for a copy of the product warranty certificate.
Conditional Parts(Registration Required) ...............................Ten (10) Years