C2O C2O C2O C2O DS-C2O-2 Ordering Information Ordering Information Ordering Information Ordering Information CALL ‘ ALL ‘ ALL ‘ ALL ‘2’ ’ ’ ’ OPEN USING YOUR MOBILE PHONE PEN USING YOUR MOBILE PHONE PEN USING YOUR MOBILE PHONE PEN USING YOUR MOBILE PHONE Features Features Features Features Easy to Configure using SMS commands. User Password Controlled Relay Output rated 1.2KW ‘White List’ upto 100 Tel No’s Signal Strength Indication Internal Antenna Waterproof Enclosure IP68 (Pressure Washer Proof) Access Control Access Control Access Control Access Control Gates / Barriers / Doors Gates / Barriers / Doors Gates / Barriers / Doors Gates / Barriers / Doors Emergency Alarms Emergency Alarms Emergency Alarms Emergency Alarms Covert Systems Covert Systems Covert Systems Covert Systems Remote Control Remote Control Remote Control Remote Control Easy Operation Easy Operation Easy Operation Easy Operation User Calls C2O C2O Rejects call If valid C2O operates Output PART No PART No PART No PART No Description Description Description Description C2O Call2Open Controller IP68 SIM-O2 Contract Simcard SMS Only
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
C2O C2O C2O C2O
DS-C2O-2
Ordering InformationOrdering InformationOrdering InformationOrdering Information
CCCCALL ‘ALL ‘ALL ‘ALL ‘2222’ ’ ’ ’ OOOOPEN USING YOUR MOBILE PHONEPEN USING YOUR MOBILE PHONEPEN USING YOUR MOBILE PHONEPEN USING YOUR MOBILE PHONE
FeaturesFeaturesFeaturesFeatures
Easy to Configure using SMS
commands.
User Password Controlled
Relay Output rated 1.2KW
‘White List’ upto 100 Tel No’s
Signal Strength Indication
Internal Antenna
Waterproof Enclosure IP68
(Pressure Washer Proof)
Access ControlAccess ControlAccess ControlAccess Control
Two relay outputs are provided on C2O and C2O-DIN, which provide a ‘switch’ output as below.
Power ConnectionsPower ConnectionsPower ConnectionsPower Connections
The C2O unit can be powered from 12 or 24Vdc, a mains power supply is also available. Power
is connected via the Power Screw Terminal.
During Initialisation After Power UPDuring Initialisation After Power UPDuring Initialisation After Power UPDuring Initialisation After Power UP
RED LED ActionRED LED ActionRED LED ActionRED LED Action DescriptionDescriptionDescriptionDescription
LED’s illuminate alternately Power-up initialisation (can take many seconds)
All LED’s flash together No network found
Normal OperationNormal OperationNormal OperationNormal Operation
RED LED ActionRED LED ActionRED LED ActionRED LED Action DescriptionDescriptionDescriptionDescription
No LEDs No signal
One LED on Steady Low signal strength
Two LEDs on Steady Medium signal strength
Three LEDs on Steady High signal strength
When Transmitting or Receiving a TEXTWhen Transmitting or Receiving a TEXTWhen Transmitting or Receiving a TEXTWhen Transmitting or Receiving a TEXT
RED LED ActionRED LED ActionRED LED ActionRED LED Action DescriptionDescriptionDescriptionDescription
One LED Flashing SMS being Received
TWO LED’s Flashing SMS being Transmitted
COM
NO
NC
Relay Connections whenNOT Operating
COM
NO
NC
Relay Connections when OPERATING
DS-C2O-2
Extending the Antenna Extending the Antenna Extending the Antenna Extending the Antenna For low signal areas the internal antenna may be replaced with an external antenna. We offer
the following options.
Please NotePlease NotePlease NotePlease Note: Fitting the bulkhead connector in the enclosure will mean that the enclosure is
no longer IP68! Additional water sealing will be required if the unit is exposed.
This cable connects onto the GSM Engine and provides a
bulkhead mounting SMA connector which may be fitted
to the enclosure, The external antenna below connect
directly.
Optional External Mount Gain AntennaOptional External Mount Gain AntennaOptional External Mount Gain AntennaOptional External Mount Gain Antenna
ANTANTANTANT----GSM5WMGSM5WMGSM5WMGSM5WM
Wall Mount Whip Antenna
Gain +5dB
Height ~250mm
3m Connecting Lead
OUTSIDEOUTSIDEOUTSIDEOUTSIDE----TSMATSMATSMATSMA
Wall Mount Antenna
Gain +3dB
Dimensions 130 x 45 x 27mm
3m Connecting Lead
GSM20GSM20GSM20GSM20----ANTANTANTANT
Magnetic mount type Whip Antenna
Gain +3db
Height ~ 236 mm (including magnetic base)
Cable length 2.5m
DS-C2O-2
ANTANTANTANT----GSMPUKSGSMPUKSGSMPUKSGSMPUKS
Rugged Low Profile ‘Puck’ Antenna
+2dBi Gain
3metres Cable
ANTANTANTANT----GSMSTUB4GSMSTUB4GSMSTUB4GSMSTUB4
Stubby Magnetic Mount
Gain: +4dBi
Height ~110mm
3m Connecting Lead
Waterproof Power Supply PSU12V1AINWaterproof Power Supply PSU12V1AINWaterproof Power Supply PSU12V1AINWaterproof Power Supply PSU12V1AIN----IPIPIPIP
Waterproof Resin Potted Unit (IP67)
Size 83 x 37 x 30mm
Input 100-240Vac Output 12Vdc 1A
Wall Fixing Lugs
Supplied with 3.3m lead
DS-C2O-2
Sending Text CommandsSending Text CommandsSending Text CommandsSending Text Commands ~ means a ‘space’ in the message.~ means a ‘space’ in the message.~ means a ‘space’ in the message.~ means a ‘space’ in the message.
Unit PasswordUnit PasswordUnit PasswordUnit Password
(UPW)
This is the first command that must be sent within 5 minutes from in-
tial power up.
The UPW can be any combination of letters/numbers from 5 to10 char-
acters.
If for any reason the unit password is lost or miss-entered the user
must remove all power to the unit for 1 minute, when power is reap-
plied the user may then use the UPW command to set a new unit pass-
word.
Command Example: UPW~Password123
Response: UPW~OK
***NOTE THIS COMMAND IS CASE SENSITIVE!***
Output delay timeOutput delay timeOutput delay timeOutput delay time
(ODEL)
This command sets an activation time of the relay outputs.
If ‘t’ is set to a value from 1 to 9 then this sets the number of seconds
for which the output remains on after an ON command.
If ‘t’ is set to ‘0’, then the output will Latch ‘ON’ permanently
Command Example: Password123~ODEL1~7
Response: UID~ODEL1~7~OK
Unit IdentityUnit IdentityUnit IdentityUnit Identity
(UID)
The <UNIT ID> is an alphanumeric string consisting 4 to 10 charac-
ters. This string of characters sets the ‘identity’ of the C2O unit, and is in-
cluded in any response to identify the C2O unit to the user
Command:
Password123~UID~Identity7
Response:
Identity7~UID~OK
DS-C2O-2
Additional Commands for using the White ListAdditional Commands for using the White ListAdditional Commands for using the White ListAdditional Commands for using the White List
Add a number to the Add a number to the Add a number to the Add a number to the
White ListWhite ListWhite ListWhite List
(WHL)
There is a max of 99 numbers that can be stored.
We advise you keep a separate list numbers their positions.
Command Example to add 1273898000 to location 4:
Password1234~WHL04~1273898000
Response: Password123~WHL04~1273898000~OK
Note: If your number has more than 23 digits, use the rightmost
ones. For example, if your number is 33446665555 you should pro-
gram 3446665555.
Check a number in the Check a number in the Check a number in the Check a number in the
White ListWhite ListWhite ListWhite List
(WHL?)
Reports back a telephone number from the White list
Command Example to report back the tel no in position 32:
Password123~WHL032?
Response: Password123~WHL032~1273898000
Delete a number in the Delete a number in the Delete a number in the Delete a number in the
White ListWhite ListWhite ListWhite List
(WHLD)
Command Example to delete the Tel no at loc’n 01:
Password123~WHL01D
Response:
Password123~WHL01~<0033612345678>~deleted
Delete ALL numbers in Delete ALL numbers in Delete ALL numbers in Delete ALL numbers in
the White Listthe White Listthe White Listthe White List
(WHLALLD)
This command Deletes all telephone numbers within the White list
from Any numberfrom Any numberfrom Any numberfrom Any number
(CTOANY)
Turns OFF White list check. When C2O receives a call from ANY Tel
number, it will activate the output, then reject the call (so there will
be no charge).
Command Example: Password123~CTOANY
Response: UID~CTOANY~OK
C2O C2O C2O C2O
DS-C2O-2
Disclaimer:Disclaimer:Disclaimer:Disclaimer:
Whilst the information in this document is believed to be correct at the time of issue, R.F.Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy or
completeness. No express or implied warranty or representation is given relating to the information contained in this document. R.F.Solutions Ltd reserves the right to make
changes and improvements to the product(s) described herein without notice. Buyers and other users should determine for themselves the suitability of any such information or
products for their own particular requirements or specification(s). R.F.Solutions Ltd shall not be liable for any loss or damage caused as a result of user’s own determination of
how to deploy or use R.F.Solutions Ltd’s products. Use of R.F.Solutions Ltd products or components in life support and/or safety applications is not authorised except with
express written approval. No licences are created, implicitly or otherwise, under any of R.F.Solutions Ltd’s intellectual property rights. Liability for loss or damage resulting or
caused by reliance on the information contained herein or from the use of the product (including liability resulting from negligence or where R.F.Solutions Ltd was aware of the
possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict R.F.Solutions Ltd’s liability for death or personal injury resulting from its negli-