Page 1: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

RF Safety

By Bob Buus, W2OD

Page 2: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

Certification 6)

• Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s Rules regarding RADIOFREQUENCY (RF) RADIATION SAFETY and the amateur service section of OST/OET Bulletin Number 65. – FCC Form 605

Page 3: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

Section 97.13(c)• Before causing or allowing an amateur station to

transmit from any place where the operation of the station could cause human exposure to RF electromagnetic field levels in excess of those allowed under § 1.1310 of this chapter, the licensee is required to take certain actions.

• (1) The licensee must perform the routine RF environmental evaluation prescribed by § 1.1307(b) of this chapter, if the power of the licensee’s station exceeds the limits given in the following table:

• (2) If the routine environmental evalation indicates that the RF electromagnetic fields could exceed the limits contained in § 1.1310 of this chapter in accessible areas, the licensee must take action to prevent human exposure to such RF electromagnetic fields. Further information on evaluating compliance with these limits can be found in the FCC’s OET Bulletin Number 65, “Evaluating Compliance with the FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields.”

Wavelength BandEvaluation required if power (watts) exceeds

160 m 500

80 m 500

75 m 500

40 m 500

30 m 425

20 m 225

17 m 125

15 m 100

12 m 75

10 m 50

VHF 50

70 cm 70

33 cm 150

23 cm 200

13 cm 250

SHF 250

EHF 250

Repeater stations 500 W ERP

Page 4: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

§ 1.1310 Limits for MPE

Limits for Occupational/Controlled Exposure over 6 minute average

Frequency, Mhz E Field, V/m H Field, A/m Pwr. Den. mW/cm2

0.3-3.0 614 1.63 100 3.0-30 1842/f 4.89/f 900/f2 30-300 61.4 0.163 1.0 300-1500 f/300 1500-100,000 5.0

Limits for General Population/Uncontrolled Exposure over 30 minute average

Frequency, Mhz E Field, V/m H Field, A/m Pwr. Den. mW/cm2

0.3-3.0 614 1.63 100 3.0-30 824/f 2.19/f 180/f2 30-300 27.5 0.073 0.2 300-1500 f/1500 1500-100,000 1.0

Page 5: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

The Human Body Heat Engine

• Absorption of RF Power causes heating

• Specific Absorption Rate (SAR) Watts/kg

• A SAR produces same heating regardless of frequency

• A human at rest produces about 1 Watt/kg

• A SAR of 4 W/kg will raise tissue temp. 1 degree – same as a brisk walk

• Avg. 4 W/kg or PK 20 W/kg in limbs safe.

Page 6: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

Living Human Properties

• The human body is a marvel at regulating its internal temperature through blood circulation and perspiration.

• Sperm in the testes are very temperature sensitive.

• The lens of the eye lacks blood flow to keep it cool. If “cooked” at high temperature, cataracts will form.

Page 7: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

RF Field Strength

• Electric E Field is in Volts per meter

• Magnetic H Field is in Amperes per meter

• Power Density, S is Watts per square meter

• S=ExH = E2/377 = 377 H2 Watts/sq. meter

• 10 Watts/sq. m = 1 milliwatt/sq. cm

• For a point source, S = Power / 4πd2

Page 8: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

Field Strength Examples

• For a point source, S = Power / 4πd2

Eff. Rad. Power Distance, d Strength, S

1250 Watts 1.0 Meter 10 mW/sq. cm

125 watts 1.0 meter 1 mW/sq. cm

125 watts 0.1 meter 100 mW/sq. cm

125 Watts 10 Meters .01 mW/ sq. cm

Page 9: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

Conversion from SAR to RF Field Strength

• Exposing a human body to 10 mW/sq. cm

• Frequency of maximum absorption (about 70 mHz)

• Localized SAR values• Average SAR is 1.88

W/kg• From Proc. IEEE 68:27,

1980

Page 10: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

FCC Requirements

• Most stringent between 30 and 300 MHz

• 20 mW/sq. cm deemed safe

• Controlled Environment less than 1 mW/ sq. cm (factor of 20)

• Uncontrolled Environment less than 0.2 mW/sq. cm (factor of 100)

• Evaluation must be done if output power exceeds 50 Watts at these frequencies.

Page 11: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

Must do Evaluation if Power Exceeds

• 500 watts below 10 MHz• 425 watts on 30 meters• 225 watts on 20 meters• 125 watts on 17 meters• 100 watts on 15 meters• 75 watts on 12 meters• 50 watts on 10 meters and at VHF• 70 watts on 70 cm• 150 watts on 33 cm• 200 watts on 23 cm• 250 watts above 2 gHz• 500 watts ERP for repeaters on all bands

Page 12: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

Evaluation Procedure

• Limits of 1.1310 vary with frequency so you must evaluate for each frequency band you plan to use

• Controlled exposure limits are 5 times the Uncontrolled exposure limits

• Controlled exposure averaging time is 6 minutes

• Uncontrolled exposure averaging time is 30 minutes

Page 13: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

Duty Cycle Advantage

• If we listen as much as we talk, the transmitter is on only 50% of the time

• For FM, PSK, and TTY, PEP is average transmitting power

• For CW, because of spaces between dots and dashes, average xmit power is 0.5 PEP

• For SSB with speech processing, the average power is about 0.2 PEP

Page 14: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

Typical Duty Cycles

Duty Cycle

Modulation Avg./PEP Talk/Listen

FM 1.0 0.5

PSK/TTY 1.0 0.5

CW 0.5 0.5

AM 0.3 0.5

SSB 0.2 0.5

Packet 1.0 0.1

Page 15: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

Radiated Power Calculation

• Average Radiated Power (6 or 30 min) =

• PEP output power (watts)

• Reduced by transmission line loss

• Times antenna gain

• Times ground reflection gain

• Reduced by Average/PEP ratio

• Reduced by Duty Cycle ratio

Page 16: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

Final Calculation

• Must determine how far away you must be from the antenna to meet the FCC requirements for both the controlled and uncontrolled environments

• Using simple 1 / 4πd2 gives conservative results. More complicated NEC analysis will permit higher power and/or closer distances

Page 17: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

To Run RF Safety Program

• Run rfsafety.exe

• Input Call

• Change any or all of the defaults by selecting from drop-down menu or typing a numeric value followed by “enter”.

• Click “Calculate” and distance results are given for controlled and uncontrolled

• Clicking “Print” will give hard copy.

Page 18: RF Safety By Bob Buus, W2OD. Certification 6) Amateur Applicant/Licensee certifies that they have READ and WILL COMPLY WITH Section 97.13(c) of the Commission’s.

THE END